HomeMy WebLinkAboutIMPALA REDEVELOPMENT - PDP220005 - DOCUMENT MARKUPS - ROUND 2 - UTILITY PLANS (2)UD
IRR IRR
IRR
XXX X X X X X
XXXXXXXXXXXXXXXXXXXXXXD
D
D
ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST STSTXXXXXXXXXXBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBSOUTH IMPALA DRIVEWEST MULBERRY STREET
IMPALA CIRCLE
EASEMENT
EXCLUSION EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
26' EMERGENCY
ACCESS
EASEMENT
26' EMERGENCY
ACCESS
EASEMENT
±31'
FL-FL (TYP.)
26'
FL-FL
PROPOSED
LANDSCAPE
WALL12' CONCRETE TRAILPROPOSED 2'
CONCRETE PAN
PROPOSED
UNDERDRAIN
PROPOSED POND
OUTLET STRUCTURE
PROPOSED
STORM DRAIN
EXISTING 15"
STORM DRAIN
OLIVE STREET
FFE=96.15
FFE=95.48
FFE=93.42
FFE=92.42
FFE=91.42
FFE=93.75
FFE=90.72
FFE=94.59
FFE=86.02
RAIN GARDEN
BIOMEDIA AREA
DETENTION
POND 1
24' EMERGENCY
ACCESS
EASEMENT
51' ACCESS &
UTILITY
EASEMENT
IMPALA CIRCLE
EXISTING DRAINAGE
OUTFALL
PROPOSED 2'
SIDEWALK CULVERT
EXISTING 36"
STORM DRAIN
DETENTION
POND 2
PROPOSED 2'
CONCRETE PANPROPOSED 3'
CONCRETE RUNDOWN
PROPOSED RIP-RAP
RUNDOWN
PROPOSED
STORM DRAIN
FFE=93.59
RAIN GARDEN
BIOMEDIA AREA
EXISTING
CONCRETE PAN
EXISTING
CONCRETE PAN
EXISTING
SIDEWALK
CULVERT
PROPOSED
UNDERDRAIN
PROPOSED
LANDSCAPE WALL PROPOSED
LANDSCAPE WALL
PROPOSED
LANDSCAPE WALL
PROPOSED
LANDSCAPE WALLS
PROPOSED
RETAINING WALL
PROPOSED SIDEWALK
CULVERT
OWNER:
TRISSELL, NICOLE/COGELL,
CHRISTOPHER
408 S IMPALA DR.
OWNER:
VON STROHEIM, ERICH
2310 W MULBERRY ST.
OWNER:
EMPIRE
GRANGE 148
2306 W
MULBERRY ST.
OWNER:
KEELER, JACK
LEE/ GAIL,
MARGARET
2302 W
MULBERRY ST.
OWNER:
RICKETTS,
THERESA A.
2300 W
MULBERRY ST.
OWNER:
VILLAGES, LTD.
400 IMPALA
CIR.
OWNER:
POUDRE R-1 SCHOOL DISTRICT
OWNER:
POUDRE R-1 SCHOOL DISTRICT
OWNER:
BAILEY, MICHAEL
2213 WOODFORD CT.
OWNER:
HAUAN, JAMES P/
PATRICIA A
2212 WOODFORD CT.
OWNER:
SIKORSKI, MITCHELL
ANDREW
2213 W MAGNOLIA CT.
OWNER:
GODING, BRYAN T.
2218 W MULBERRY ST.
OWNER:
STEADMAN, VIVIAN LOUISE
2212 W MAGNOLIA CT.
NORTH
( IN FEET )
1 inch = ft.
Feet05050
50
100 150
SheetIMPALA REDEVELOPMENTThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 18
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
C 400OVERALL GRADING PLAN 13
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
PROPOSED SLOPES
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL
UNKNOWN UNDERGROUND UTILITIES.
2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD88. SEE COVER SHEET FOR
BENCHMARK REFERENCES.
4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE
FINISHED GRADE ELEVATIONS.
5.LOT GRADING IS DESIGNED FOR TYPICAL RECTANGULAR FOOTPRINT WITH
DIMENSIONS AS SHOWN HEREON. SHOULD BUILDING FOOTPRINT CHANGE,
GRADING SHALL BE ADJUSTED BY PLOT PLAN FOR THE SPECIFIC FOOTPRINT. ALL
MINIMUM OPENINGS SHALL BE A MINIMUM OF 18" ABOVE FRONT LOT ELEVATIONS
AND PLOT PLAN DESIGN SHALL MEET FHA GRADING GUIDELINES AND BUILDING
CODE REQUIREMENTS.
NOTES:
PROPOSED STORM INLET
2.0%
(47.45
)
EXISTING SPOT ELEVATION
EXISTING LOT LINE
PROPOSED CONCRETE
CROSS PAN (TYP.)
33.43
EXISTING RIGHT OF WAY
PROPOSED LOT LINE
PROPOSED RIGHT OF WAY
LEGEND:
PROPOSED GRADE BREAK
KEYMAP
C 401
C 402
C 403
UDUD
XXXXXXXXXXXXXXXXXXXXXXXXXXXXD
D
ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST STSTST975085 (NAVD88)5084 (NAVD88)5083 (NAVD88)5082 (NAVD88)FFE=86.02
WEST MULBERRY STREET
5' SIDEWALK6' SIDEWALK12' CONCRETE TRAILDETENTION
POND 2
PROPOSED
STORM DRAIN
EXISTING
BUILDINGS
(TYP.)
PROPOSED 2'
SIDEWALK CULVERT
EXISTING 2'
CONCRETE PAN
EXISTING 15"
STORM DRAIN
EXISTING 36"
STORM DRAIN
EASEMENT
EXCLUSION
PROPOSED RIP-RAP
RUNDOWN
EXISTING 10'
IRRIGATION
EASEMENT
51.5' ACCESS &
UTILITY
EASEMENT
EXISTING HEADWALL
& OVERFLOW WEIR
RAIN GARDEN
BIOMEDIA AREA
PROPOSED
STORM DRAIN(86.86)(8
6
.
5
9
)
PROPOSED
SAWCUT 83.4082.088
3
.
0
8
85.358
5
.
3
5
8
5
.
3
9
(83.05)84.8585.35
85.3584.54(84.62)84.
3
3 81.33(0.2%)(4.1%)(1.7%)(0.3%)2.3%(1.0%)
1.3%1.4%(1.4%)(0.4%)PROPOSED
SAWCUT
EXISTING VERTICAL
CURB & GUTTER
TIE TO EXISTING
SIDEWALK
EXISTING VERTICAL
CURB & GUTTER
EXISTING VERTICAL
CURB & GUTTER
OWNER:
VON STROHEIM, ERICH
2310 W MULBERRY ST.
OWNER:
EMPIRE GRANGE 148
2306 W MULBERRY ST.
OWNER:
KEELER, JACK LEE/ GAIL, MARGARET
2302 W MULBERRY ST.
OWNER:
RICKETTS, THERESA A.
2300 W MULBERRY ST.
OWNER:
VILLAGES, LTD.
400 IMPALA CIR.OWNER:
SIKORSKI, MITCHELL ANDREW
2213 W MAGNOLIA CT.
OWNER:
GODING, BRYAN T.
2218 W MULBERRY ST.
OWNER:
VILLAGES, LTD.
400 IMPALA CIR.
CITY OF FORT COLLINS
100-YR FLOODWAY
CITY OF FORT COLLINS
100-YR HIGH-RISK
FLOOD FRINGE
CITY OF FORT COLLINS
100-YR HIGH-RISK
FLOOD FRINGE
NORTH
( IN FEET )
1 inch = ft.
Feet02020
20
40 60
KEYMAP UPSheetIMPALA REDEVELOPMENTThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 18
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
PROPOSED SLOPES
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL
UNKNOWN UNDERGROUND UTILITIES.
2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD88. SEE COVER SHEET FOR
BENCHMARK REFERENCES.
4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE
FINISHED GRADE ELEVATIONS.
5.LOT GRADING IS DESIGNED FOR TYPICAL RECTANGULAR FOOTPRINT WITH
DIMENSIONS AS SHOWN HEREON. SHOULD BUILDING FOOTPRINT CHANGE,
GRADING SHALL BE ADJUSTED BY PLOT PLAN FOR THE SPECIFIC FOOTPRINT. ALL
MINIMUM OPENINGS SHALL BE A MINIMUM OF 18" ABOVE FRONT LOT ELEVATIONS
AND PLOT PLAN DESIGN SHALL MEET FHA GRADING GUIDELINES AND BUILDING
CODE REQUIREMENTS.
NOTES:
PROPOSED STORM INLET
2.0%
(47.45
)
EXISTING SPOT ELEVATION
EXISTING LOT LINE
PROPOSED CONCRETE
CROSS PAN (TYP.)
33.43
EXISTING RIGHT OF WAY
PROPOSED LOT LINE
PROPOSED RIGHT OF WAY
LEGEND:
PROPOSED GRADE BREAK
MATCH LINE - SEE SHEET C 402
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
C 403GRADING PLAN 16
C 401
C 402
C 403
XXX XXXXXX XX X
XXX
XXX
X X X X X X
XXXXXXXXXXXXXXXXXXXXXXWW WW WWWWWWWWWWWWWWWWWWWWWWWWWW
WWWWWWWWWWWWWWWWWWWWWWWWWWWWWW WW
WWWWWWWWWWWWWWWWWWWW WW WWWWWWWWWW WWWWWWWWWW
WWWWIRRIRRIRR IRR IRR
D
D
D
ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST STSTXXXXXXXXXXTTTTT45088 (NAVD88)28975087 (NAVD88)5086 (NAVD88)5085 (NAVD88)5084 (NAVD88)5083 (NAVD88)5082 (NAVD88)5081 (NAVD88)5080 (NAVD88)POND 1
POND 2
100
101
OS1
IMPALA CIRCLE
SOUTH IMPALA DRIVEWEST MULBERRY STREET
IMPALA CIRCLE
OLIVE STREET
EXISTING 15"
STORM DRAIN
EXISTING 36"
STORM DRAIN
EXISTING 2'
CONCRETE PAN
EXISTING HEADWALL &
OVERFLOW WEIR
EXISTING HEADWALL &
OVERFLOW WEIR
CITY OF FORT COLLINS
100-YR FLOODWAY
CITY OF FORT COLLINS
100-YR HIGH-RISK
FLOOD FRINGE
CITY OF FORT COLLINS
100-YR HIGH-RISK
FLOOD FRINGE
OS1
200
OS2
100
OS4
102
101
OS3
C 500DRAINAGE EXHIBITHISTORIC17
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
NORTH
( IN FEET )
1 inch = ft.
Feet05050
50
100 150
PROPOSED CONTOUR
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROPOSED INLET
A
DESIGN POINT
FLOW ARROW
DRAINAGE BASIN LABEL
DRAINAGE BASIN BOUNDARY
PROPOSED SWALE SECTION
11
NOTES:
1.REFER TO THE PRELIMINARY DRAINAGE REPORT, DATED APRIL 13, 2022 BY
NORTHERN ENGINEERING FOR ADDITIONAL INFORMATION.
A
LEGEND:
FOR DRAINAGE REVIEW ONLY
NOT FOR CONSTRUCTION
SheetIMPALA REDEVELOPMENTThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 18
XXX X X X X X
XXXXXXXXXXXXXXXXXXXXXXD
D
D
ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST STSTXXXXXXXXXXW
SS4
2897BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBOS1
102
200
OS2
101
OS3
100
101
OS1
102
UDTT
T
200
OS3 OS4
OS2
EXISTING 10'
EASEMENT
IMPALA CIRCLE
SOUTH IMPALA DRIVEWEST MULBERRY STREET
IMPALA CIRCLE
OLIVE STREET
DETENTION
POND 2
RAIN
GARDEN 1
DETENTION
POND 1
EXISTING 36"
STORM DRAIN
EXISTING 15"
STORM DRAIN
PROPOSED 6'
CONCRETE PAN
PROPOSED 2'
CONCRETE PAN
PROPOSED OUTLET
STRUCTURE
EXISTING 2'
CONCRETE PAN
PROPOSED 2'
SIDEWALK CULVERT
PROPOSED
RIPRAP RUNDOWN
PROPOSED
STORM DRAIN
PROPOSED 4'
CONCRETE RUNDOWN
RAIN GARDEN 2
PROPOSED
STORM DRAIN
PROPOSED
STORM DRAIN
PROPOSED STORM
DRAIN
OS4
PROPOSED 2'
CONCRETE PAN
100
EXISTING
HEADWALL
EXISTING
HEADWALL
OS5
OS5
5088 (NAVD88)5087 (NAVD88)5086 (NAVD88)5085 (NAVD88)5084 (NAVD88)5083 (NAVD88)5082 (NAVD88)5081 (NAVD88)5080 (NAVD88)CITY OF FORT COLLINS
100-YR FLOODWAY
CITY OF FORT COLLINS
100-YR HIGH-RISK
FLOOD FRINGE
CITY OF FORT COLLINS
100-YR HIGH-RISK
FLOOD FRINGE
C 501DRAINAGE EXHIBIT18
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
NORTH
( IN FEET )
1 inch = ft.
Feet05050
50
100 150
PROPOSED CONTOUR
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROPOSED INLET
A
DESIGN POINT
FLOW ARROW
DRAINAGE BASIN LABEL
DRAINAGE BASIN BOUNDARY
PROPOSED SWALE SECTION
11
NOTES:
1.REFER TO THE PRELIMINARY DRAINAGE REPORT, DATED APRIL 13, 2022 BY
NORTHERN ENGINEERING FOR ADDITIONAL INFORMATION.
A
LEGEND:
FOR DRAINAGE REVIEW ONLY
NOT FOR CONSTRUCTION
SheetIMPALA REDEVELOPMENTThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 18