HomeMy WebLinkAboutMONTAVA - PHASE G & IRRIGATION POND - BDR210013 - SUBMITTAL DOCUMENTS - ROUND 2 - STORMWATER-RELATED DOCUMENTSmemorandum To: Max Moss, Montava From: Rachel Kullman, P.E. Date: March 3th, 2022 Re: Accounting Concepts for Montava Non-potable Irrigation Ponds In this memorandum I include an overview of the various accounting concepts that will be required for non-potable irrigation ponds at Montava, including the West Pond, East Pond and the Farm Pond. Pond Inflows • Sources of potential inflow for West Pond only: o WSSC shares (potentially from both Montava and Fort Collins) o Groundwater from existing Montava wells (including one Portner well) o Groundwater from existing Fort Collins wells (including one Portner well) o Groundwater from proposed new Montava well o The pond should be constructed so as to prevent long-term retention of stormwater inflows. o The planned clay liner will prevent groundwater seepage inflows • Sources of potential inflow for East Pond only: o NPIC shares (potentially from both Montava and other entities) o WSSC shares (potentially from both Montava and other entities) o Groundwater from existing Montava wells o Groundwater from proposed new Montava well o The pond should be constructed so as to prevent long-term retention of stormwater inflows. o The planned clay liner will prevent groundwater seepage inflows • Sources of potential inflow for Farm Pond only: o NPIC shares o WSSC shares o Groundwater from existing Montava wells o The pond should be constructed so as to prevent long-term retention of stormwater inflows. o The planned clay liner will prevent groundwater seepage inflows • All sources of inflow should be measured at least on a daily basis before delivery to the pond(s). 2 Phone : 505-690-1432 I Email : rachel@kullmanwater.com I Web : www.kullmanwater.com Address: P.O. Box 5464 Santa Fe, NM 87502 o Each well will need to be measured independently as water is pumped from the aquifer (it may not be necessary to measure each well separately as delivered into the pond(s), if piped from the wellhead). o WSSC and NPIC deliveries to the pond(s) (or property if piped to pond(s)) will need to be measured. It may not be necessary to separately measure deliveries by entity in the case of the West and East Pond, if simultaneous deliveries can be prorated. Pond Outflows • Sources of potential outflow for West Pond only: o Fort Collins’ irrigation uses under the various water sources:  WSSC shares, groundwater from Montava’s existing groundwater wells or Fort Collins’ existing groundwater well. o Montava’s irrigation uses under the various water sources:  WSSC shares, groundwater from Montava’s existing groundwater wells o Groundwater from the new Montava well will be used to fill the pond initially and to offset evaporation losses during the non-irrigation season. Groundwater from the new well will not be released from the pond. o Evaporation losses  Evaporation losses will be calculated using unit daily evaporation rates and the amount of surface water exposed in the pond on a daily basis.  The surface area will be determined from a staff gage placed in the pond and an associated stage-area curve/chart.  Evaporation losses will be calculated during the irrigation season and non-irrigation season on a daily basis. Irrigation season losses will be deducted from the various water source accounts held in the pond, likely on a pro-rata basis. Non-irrigation season losses will be deducted from the stored groundwater pumped from Montava’s new well. o The proposed clay liner will prevent groundwater seepage outflows • Sources of potential outflow for East Pond only: o Montava’s irrigation uses (and other entity uses, if applicable) under the various water sources:  NPIC shares, WSSC shares, groundwater from Montava’s existing groundwater wells o Groundwater from the new Montava well will be used to fill the pond initially and to offset evaporation losses during the non-irrigation season. Groundwater from the new well will not be released from the pond. o Evaporation losses  Evaporation losses will be calculated using unit daily evaporation rates and the amount of surface water exposed in the pond on a daily basis.  The surface area will be determined from a staff gage placed in the pond and an associated stage-area curve/chart.  Evaporation losses will be calculated during the irrigation season and non-irrigation season on a daily basis. Irrigation season losses will be deducted from the various water source accounts held in the pond, likely 3 Phone : 505-690-1432 I Email : rachel@kullmanwater.com I Web : www.kullmanwater.com Address: P.O. Box 5464 Santa Fe, NM 87502 on a pro-rata basis. Non-irrigation season losses will be deducted from the stored groundwater pumped from Montava’s new well. o The proposed clay liner will prevent groundwater seepage outflows • Sources of potential outflow for Farm Pond only: o Montava’s irrigation uses under the various water sources:  NPIC shares, WSSC shares, groundwater from Montava’s existing groundwater wells o Evaporation losses  Evaporation losses will be calculated using unit daily evaporation rates and the amount of surface water exposed in the pond on a daily basis.  The surface area will be determined from a staff gage placed in the pond and an associated stage-area curve/chart.  Evaporation losses will be calculated during the irrigation season and non-irrigation season on a daily basis. Irrigation season losses will be deducted from the various water source accounts held in the pond, likely on a pro-rata basis. Non-irrigation season losses will not occur because the Farm Pond is anticipated to be empty during the non-irrigation season. o The proposed clay liner will prevent groundwater seepage outflows • All sources of outflow should be measured at least on a daily basis as released from the pond(s). o At a minimum, Fort Collins’ total irrigation uses/outflows and Montava’s total irrigation uses/outflows should be measured in the case of the West Pond. o At a minimum, any other entity’s total irrigation uses/outflows (if applicable) and Montava’s total irrigation uses/outflows should be measured in the case of the East Pond. o At a minimum, Montava’s total irrigation uses/outflows should be measured in the case of the Farm Pond. o Use of water from Montava’s existing groundwater wells (and Fort Collins’ well for the West Pond) are restricted to particular locations by permit and decree and it will be necessary to ensure compliance with these limitations to the extent such sources are used on the irrigated areas. It may be necessary to meter groundwater distribution at strategic locations in the non-potable system in order to quantify and account for these limitations. o NPIC shares cannot be used for irrigation west of Giddings Road. When developing the accounting for the East Pond and Farm Pond, this limitation should be tracked. o For the West Pond, once irrigated areas for each entity are determined/finalized, it may be necessary to include additional measurement points as water is distributed for irrigation in order to accurately account for each entity’s share of the groundwater and the WSSC shares. Storage Accounts 4 Phone : 505-690-1432 I Email : rachel@kullmanwater.com I Web : www.kullmanwater.com Address: P.O. Box 5464 Santa Fe, NM 87502 • For the West Pond, it will be necessary to account for the amount of water stored in the pond on a daily basis by entity (i.e. Montava vs. Fort Collins), for all sources of water (i.e. “colors”). • For the East Pond, it will be necessary to account for the amount of water stored in the pond on a daily basis by entity (i.e. Montava vs. other entity, if applicable), for all sources of water (i.e. “colors”). • For the Farm Pond, it will be necessary to account for the amount of water stored in the pond on a daily basis for all sources of water (i.e. “colors”). • In order to quantify the amount of water stored for each entity/color account, it will be necessary to parse out inflows and outflows into the appropriate accounts. The methodology used to complete this parsing of sources will be based on various criteria and limitations associated with both the sources and uses of water (some of which are described in the next section). Limitations on Use of Water • WSSC and NPIC shares: o Share deliveries should not be stored in the pond(s) more than 72 hours because the shares will not be decreed for storage purposes in the ponds. o Share deliveries should not be made on lands that are not within the historical service area of the ditch system, unless specific approval is granted otherwise. • Montava’s and Fort Collins’ existing groundwater wells: o Groundwater from these wells should not be stored in the pond(s) more than 72 hours because the groundwater is not decreed for storage purposes in the pond(s). o Each groundwater well will have limitations or restrictions by decree and permit that will need to be considered and monitored, including:  Decreed/permitted flow rate  Decreed/permitted place of use  Decreed/permitted annual volumetric limit  Augmented annual volumetric limit (if different from decree/permit) o As previously mentioned, it will be necessary to track/account for groundwater use from these wells to the point of application at the various irrigation sites in order to demonstrate compliance. Additional measurement may be necessary in order to comply. • Montava’s new groundwater wells: o Use of groundwater from these well(s) will allow Montava to keep the pond full during the non-irrigation season. o The limitation on use from these well(s) will be permitted uses and volumetric amounts determined under the new augmentation plan decree or substitute water supply plan. 5 Phone : 505-690-1432 I Email : rachel@kullmanwater.com I Web : www.kullmanwater.com Address: P.O. Box 5464 Santa Fe, NM 87502 Figures 1 through 3 include schematics of the West Pond, East Pond and Farm Pond, respectively. Table 1 includes water rights information associated with Montava’s existing groundwater wells, as well as Fort Collins’ Portner Well. Figure 4 shows the decreed location for the wells listed in Table 1. Figure 1. Montava West Pond Accounting Schematic Key: Measurement Point Inflow / Outflow Note: Schematic is provided for conceptual purposes only. Not to scale. CLAY LINER = NO LOSSES WSSC SHARES > Montava >Fort Collins EXISTING WELLS > Montava:Wells #s 16-19 > Montava:1 Portner Well > Fort Collins: 1 Portner Well > No new augmentation requirements NEW WELL > Montava to augment MONTAVA'S STORAGE ACCOUNTS > WSSC shares > Groundwater from Wells #s: 16-19, Portner 1-2 > Groundwater from New Well WEST IRRIGATION POND USES BY FORT COLLINS > WSSC Shares >Well water (from Montava & Fort Collins wells) USES BY MONTAVA > WSSC Shares >Well water EVAPORATION FORT COLLINS' STORAGE ACCOUNTS > WSSC shares > Groundwater from Wells #s: 16-19, Portner 1-2 STAFF GAGE TO DETERMINE SURFACE WATER AREA Figure 2. Montava East Pond Accounting Schematic Key: Measurement Point Inflow / Outflow Note: Schematic is provided for conceptual purposes only. Not to scale. CLAY LINER = NO LOSSES NPIC SHARES > Montava > Other entity WSSC SHARES > Montava > Other entity EXISTING WELLS > Montava:Wells #s 16-19 > Other entity groundwater wells, if applicable > No new augmentation requirements NEW WELL > Montava to augment MONTAVA'S STORAGE ACCOUNTS > NPIC shares > WSSC shares > Groundwater from Wells #s: 16-19 > Groundwater from New Well EAST IRRIGATION POND USES BY MONTAVA > NPIC Shares > WSSC Shares >Well water EVAPORATION STAFF GAGE TO DETERMINE SURFACE WATER AREA OTHER ENTITY STORAGE ACCOUNT (if applicable) > WSSC shares > NPIC shares > Groundwater USES BY OTHER ENTITY (if applicable) > WSSC Shares > NPIC shares >Well water Figure 3. Montava Farm Pond Accounting Schematic Key: Measurement Point Inflow / Outflow Note: Schematic is provided for conceptual purposes only. Not to scale. CLAY LINER = NO LOSSES NPIC SHARES > Montava WSSC SHARES > Montava EXISTING WELLS > Montava:Wells #s 16-19 > No new augmentation requirements MONTAVA'S STORAGE ACCOUNTS > NPIC shares > WSSC shares > Groundwater from Wells #s: 16-19 FARM IRRIGATION POND USES BY MONTAVA > NPIC Shares > WSSC Shares >Well water EVAPORATION STAFF GAGE TO DETERMINE SURFACE WATER AREA 1617 87 4 5 6 321 9 1110 1819 32 33 34 05 04 31 0306 2829 2730 Sources: Esri, HERE, Garmin, USGS, Intermap, INCREMENT P, NRCan, Esri Japan, METI, Esri China (Hong Kong), Esri Korea, Esri (Thailand), NGCC, (c) OpenStreetMap contributors, and the GIS User C ommunity, Source: Esri, DigitalGlobe, GeoEye, Earthstar Geographics, CNES/Airbus DS, USDA, USGS, AeroGRID, IGN, and the GIS User Community - 0 0.25 0.5 Miles FI GU R E 4 . DE CR EE D W E L L L OC AT I O N S Marc h 2 022 Legend Decreed Well Location Section Lines Montava Table 1. Montava Well Information Well Name Portner Well No. 1 Portner Well No. 2 Kluver PS 1: Well No. 1 Kluver PS 1: Well No. 2 Fitzsimons Well No. 1 Fitzsimons Well No. 2 Bachmayr Well No. 4 Bachmayr Well No. 5 Kluver PS: Well No. 2 Kluver PS 5: Well No. 1 Kluver PS 5: Well No. 2 Kluver Well Albertson Well No. 10 Albertson Well No. 11 Albertson Well No. 12 Map Identification No.7 8 19 18 17 16 10 11 9 1 2 3 6 5 4 T-R-S T8N-R68W-32 T8N-R68W-32 T8N-R68W-32 T8N-R68W-32 T8N-R68W-32 T8N-R68W-32 T8N-R68W-33 T8N-R68W-33 T8N-R68W-33 T7N-R68W-4 T7N-R68W-4 T7N-R68W-4 T7N-R68W-4 T7N-R68W-4 T7N-R68W-4 Quarter Section SW SW SE SE NE NE NW NW SW NW NW NW NE NE NE Permit No.1-0494 2-0495 19196-R 19196-SR 11370-R 11372-R 328-RD-R 329-RD-R 19197-R 19200R 19200S 1-20143R 28278-F 18056-RR 18053-RF WDID 0306121 0306863 0305474 0305853 0305972 0306100 0306430 0306433 0305303 0305526 0306199 0306677 0306221 0305001 0305002 Case No.W2896 W2896 CA11217 CA11217 CA11217 CA11217 CA11217 CA11217 CA11217 CA11217 CA11217 W699 W1621 / 85CW184 W1621 W1621 Augmentation Status Poudre Plan Poudre Plan Coffin: non- tributary Coffin: non- tributary Coffin: non- tributary Coffin: non- tributary Coffin: non- tributary Coffin: non- tributary Coffin: non- tributary Coffin: non- tributary Coffin: non- tributary Poudre Plan Poudre Plan Poudre Plan Poudre Plan Decreed Acreage 90 acres NA Decreed Place of Use SW33 S4 Decreed Flow Rate 2.11 cfs 1.89 cfs 700 gpm 800 gpm 2 cfs 2 cfs 1.5 cfs 1.5 cfs 1000 gpm 450 gpm 800 gpm 495 gpm 680 gpm 2.3 cfs 2.84 cfs NE4 155 acres 160 acres 160 acres 320 acres 160 acres 106 acres SW32 SE32 NE32 N1/2 of 33 NW4