Loading...
HomeMy WebLinkAboutOFFICE AND LIGHT INDUSTRIAL ON TECHNOLOGY PARKWAY - FDP220007 - SUBMITTAL DOCUMENTS - ROUND 1 - LANDSCAPE PLAN (2)TFDC BUILDING AREATotal Net Usable Area:50,960 SFFIRE RISERBUILDING AREATotal Net Usable Area:50,960 SFFIRE RISER15 12 13 14 16 17 18 152014161718191718 1919 1919 20 20 20 18 19 1716161717 18161718 1716171818 1920181920 18 1 9 2018 192020 201011 12 1320181920 18 1819 15 1513 16 1617 1718 14 19 1918 20 19 18 1820 18 19 1718151416171818 18 17 18172018 18 15 14 14 15 1415 15 17 17 17 16 16 16 17 TECHNOLOGY PARKWAYROCK CREEK DR.PRECISION DR.TECHNOLOGY PARKWAY2"2"2"2"2"2"2"2"2"2"2"2"2"2"2"2"2"2"2"2"2"2"2"2"2"2"2"2"2"2"1.25"1.25"1.5"1.25"1.25"1.5"1.25"1.25"1.25"1.25"2"1.25"1.25"1.25"1.25"2"2"1.25"1.5"1.5"1.25"1.25"1.25"2"1.5"1.25"1.25"1.25"1.25"88888888888888888Q1.5"44-1.5"45-1.5"30-1.5"33-1.5"48-1.5"42-2"1.5"1.25"1.5"37-1"9-2"1.25"1.5"32-1.25"1.25"1"22-POINT-OF-CONNECTIONSIZE: 1-1/2-INCHFLOW: 50 GPM (MAX)AVAILABLE PRESSURE: 70 PSI (STATIC)REQUIRED PRESSURE: 50 PSI (DYNAMIC)NOTES: MEP CONTRACTOR TO PROVIDE AND INSTALL 1-1/2-INCHREDUCED PRESSURE BACKFLOW FOR IRRIGATION SYSTEMPER LOCAL CODES WITHIN FIRE RISER ROOM. MEP CONTRACTOR TO PROVIDEAND INSTALL 1-1/2-INCH TYPE K HARD COPPER (BELOW FROST DEPTH) FROMFIRE RISER ROOM TO THE POINT-OF-CONNECTION LOCATION. IRRIGATIONCONTRACTOR RESPONSIBLE FOR IRRIGATION INSTALLATION DOWNSTREAMOF POINT-OF-CONNECTION.MFBAIRRIGATION CONTROLLER*WALL MOUNTED WITHIN FIRE RISER ROOM*120 VAC POWER REQUIRED FOR CONTROLLER*MEP TO PROVIDE AND INSTALL 1-1/2-INCH CONDUIT FROMCONTROLLER TO LANDSCAPED AREA1.5" CONDUIT (BY MEP)1.5" TYPE K COPPER (BY MEP) BELOWFROST DEPTH2"2"1.5"1.5"SLEEVING1, 4-INCH (FOR MAINLINE)1, 2-INCH (FOR TWO WIRE CABLE)SLEEVING1, 4-INCH (FOR MAINLINE)1, 2-INCH (FOR TWO WIRE CABLE)SLEEVING1, 4-INCH (FOR LATERAL)1, 2-INCH (FOR MANIFOLD)1"5-1"3-1"6-SLEEVING1, 4-INCH (FOR MAINLINE)1, 2-INCH (FOR TWO WIRE CABLE)SLEEVING1, 4-INCH (FOR MAINLINE)1, 2-INCH (FOR TWO WIRE CABLE)SLEEVING1, 4-INCH (FOR MAINLINE)1, 2-INCH (FOR TWO WIRE CABLE)R1234444WQ2"2"2"2"888888888888888888888888888888888Q2"2"1.5"1.25"1.5"42-2"2"1.5"1.5"1.25"1.5"42-2"1.25"1.5"1.25"1.25"1.5"42-1.5"1.5"1.25"1.5"28-2"1.5"1.25"1.25"1.5"1.25"1.25"2"1.25"1.5"33-2"1.25"1.5"1.25"1.25"1.25"1.5"49-2"1.25"1.25"1.25"1.25"1.5"42-2"1.25"1.25"1.5"35-2"2"1.25"1.5"1.25"1.5"42-Q1.5"1.5"1.25"1.25"1.5"28-.25 .25.25 .25 .25.25.25 .25 .25 .25.25.25.25.25.25 .25 .25 .25 .25.25.25 .25 .25 .25 .25 .25.25 .25 .25 .25 .25 .25 .25 .25 .25 .25 .25 .25 .25 .25 .25 .25.25.25.25 .25 .25.25.25 .25 .25 .25.25.25 .25 .25 .25 .25 .25.25 .25 .25 .25 .25 .25 .25 .25 .25 .25 .25.25.25 .25.25 .25 .25 .25 .25 .25 .25 .25 .25 .25 .25 .25 .25 .25 .25 .25 .25 .25 .251.5"1.25"1.25"1"23-2"2"2"2"2"2"2"2"1"2-SUBMETER (IRRIGATION)FOR DETENTION POND AREA5Sheet Date:Sheet Number:Drawing Name:Drawn b\:Designed b\:RevisionsChecked b\:Project Number:Project: Client:1603 Oakridge Drive FortCollins, CO 80525(970) 223-7577www.bhadesign.comLandscape ArchitectureUrban DesignPlanning5041 TECHNOLOGY PARKWAY FDP MAVD 2723 SOUTH STATE ST, STE. 250 ANN ARBOR MI, 48104JK/SBJK/SBRBPDR2000114/27/2022IR1.0NOT FOR CONSTRUCTIONPRELIMINARY DESIGNNOT FOR CONSTRUCTIONPRELIMINARY DESIGNNOT FOR CONSTRUCTIONNOT FOR CONSTRUCTIONGENERAL NOTESLEGENDMQAA-11"15-BF1.51.5.25RWFLAG NOTES1234567GENERAL DESCRIPTIONIRRIGATIONCOVER SHEETKEYMAPN.T.S.IR2.0IR2.1ROCK CREEK DRIVETECHNOLOGY PARKWAY PRECISION DRIVE TFDC 2'' W BUILDING AREATotal Net Usable Area:50,960 SFFIRE RISERBUILDING AREATotal Net Usable Area:50,960 SFFIRE RISER152014161718191718 1919 1919 20 20 20 18 19 17 2018 192020 20131617 18 19 20 19 18 1820 18 19 18 18172018 18 15 1414 15 141515 1 7 17161617 TECHNOLOGY PARKWAY PRECISION DR.TECHNOLOGY PARKWAY2"2"2"2"2"2"2"2"2"2"2"2"2"2"1.25"1.5"1.5"1.25"1.25"1.25"88888888881.5"48-2"1.5"1.25"1.5"37-1"9-2"1.25"1.5"32-1.25"1.25"1"22-POINT-OF-CONNECTIONSIZE: 1-1/2-INCHFLOW: 50 GPM (MAX)AVAILABLE PRESSURE: 70 PSI (STATIC)REQUIRED PRESSURE: 50 PSI (DYNAMIC)NOTES: MEP CONTRACTOR TO PROVIDE AND INSTALL 1-1/2-INCHREDUCED PRESSURE BACKFLOW FOR IRRIGATION SYSTEMPER LOCAL CODES WITHIN FIRE RISER ROOM. MEP CONTRACTOR TO PROVIDEAND INSTALL 1-1/2-INCH TYPE K HARD COPPER (BELOW FROST DEPTH) FROMFIRE RISER ROOM TO THE POINT-OF-CONNECTION LOCATION. IRRIGATIONCONTRACTOR RESPONSIBLE FOR IRRIGATION INSTALLATION DOWNSTREAMOF POINT-OF-CONNECTION.MFBAIRRIGATION CONTROLLER*WALL MOUNTED WITHIN FIRE RISER ROOM*120 VAC POWER REQUIRED FOR CONTROLLER*MEP TO PROVIDE AND INSTALL 1-1/2-INCH CONDUIT FROMCONTROLLER TO LANDSCAPED AREAC 1.5" CONDUIT (BY MEP)1.5" TYPE K COPPER (BY MEP) BELOWFROST DEPTH2"2"1.5"1.5"SLEEVING1, 4-INCH (FOR MAINLINE)1, 2-INCH (FOR TWO WIRE CABLE)SLEEVING1, 4-INCH (FOR MAINLINE)1, 2-INCH (FOR TWO WIRE CABLE)SLEEVING1, 4-INCH (FOR LATERAL)1, 2-INCH (FOR MANIFOLD)1"5-1"3-SLEEVING1, 4-INCH (FOR MAINLINE)1, 2-INCH (FOR TWO WIRE CABLE)R12344WQ2"2"2"2"888888888888888888882"1.25"1.5"1.25"1.25"1.25"1.5"49-2"1.25"1.25"1.25"1.25"1.5"42-2"1.25"1.25"1.5"35-2"2"1.25"1.5"1.25"1.5"42-Q1.5"1.5"1.25"1.25"1.5"28-.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.251.5"1.25"1"23-2"2"2"2"SUBMETER (IRRIGATION)FOR DETENTION POND AREA5Sheet Date:Sheet Number:Drawing Name:Drawn b\:Designed b\:RevisionsChecked b\:Project Number:Project: Client:1603 Oakridge Drive FortCollins, CO 80525(970) 223-7577www.bhadesign.comLandscape ArchitectureUrban DesignPlanning5041 TECHNOLOGY PARKWAY FDP MAVD 2723 SOUTH STATE ST, STE. 250 ANN ARBOR MI, 48104JK/SBJK/SBRBPDR2000114/27/2022IR2.0NOT FOR CONSTRUCTIONPRELIMINARY DESIGNNOT FOR CONSTRUCTIONPRELIMINARY DESIGNNOT FOR CONSTRUCTIONNOT FOR CONSTRUCTIONIRRIGATION PLANMATCHLINE SEE SHEET IR2.11" =20'0'10'20'40'20' 15121314 16 1718 16161717 18161718 1716171818 1920181920 18 1 9101112 2018192 0 18 1819 15151316171419 18171815141617181817 17 16 TECHNOLOGY PARKWAYROCK CREEK DR.2"2"2"2"2"2"2"2"2"2"2"2"2"2"2"2"2"2"1.25"1.25"1.5"1.25"1.25"1.5"1.25"1.25"1.25"1.25"2"1.25"1.25"1.25"1.25"2"1.5"1.25"1.25"1.25"1.25"8888888Q1.5"44-1.5"45-1.5"30-1.5"33-1.5"42-1"6-SLEEVING1, 4-INCH (FOR MAINLINE)1, 2-INCH (FOR TWO WIRE CABLE)SLEEVING1, 4-INCH (FOR MAINLINE)1, 2-INCH (FOR TWO WIRE CABLE)4488888888888888Q2"2"1.5"1.25"1.5"42-2"2"1.5"1.5"1.25"1.5"42-2"1.25"1.5"1.25"1.25"1.5"42-1.5"1.5"1.25"1.5"28-2"1.5"1.25"1.25"1.5"1.25"1.25"2"1.25"1.5"33-.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.251.25"2"2"2"2"1"2-Sheet Date:Sheet Number:Drawing Name:Drawn b\:Designed b\:RevisionsChecked b\:Project Number:Project: Client:1603 Oakridge Drive FortCollins, CO 80525(970) 223-7577www.bhadesign.comLandscape ArchitectureUrban DesignPlanning5041 TECHNOLOGY PARKWAY FDP MAVD 2723 SOUTH STATE ST, STE. 250 ANN ARBOR MI, 48104JK/SBJK/SBRBPDR2000114/27/2022IR2.1NOT FOR CONSTRUCTIONPRELIMINARY DESIGNNOT FOR CONSTRUCTIONPRELIMINARY DESIGNNOT FOR CONSTRUCTIONNOT FOR CONSTRUCTIONIRRIGATION PLANMATCHLINE SEE SHEET IR2.01" =20'0'10'20'40'20' Sheet Date:Sheet Number:Drawing Name:Drawn b\:Designed b\:RevisionsChecked b\:Project Number:Project: Client:1603 Oakridge Drive FortCollins, CO 80525(970) 223-7577www.bhadesign.comLandscape ArchitectureUrban DesignPlanning5041 TECHNOLOGY PARKWAY FDP MAVD 2723 SOUTH STATE ST, STE. 250 ANN ARBOR MI, 48104JK/SBJK/SBRBPDR2000114/27/2022IR3.0NOT FOR CONSTRUCTIONPRELIMINARY DESIGNNOT FOR CONSTRUCTIONPRELIMINARY DESIGNNOT FOR CONSTRUCTIONNOT FOR CONSTRUCTIONIRRIGATIONDETAILS1WINTERIZATIONASSEMBLYN.T.S.NOTES:1. TRANSITION TO MINIMUM BURIAL DEPTH DOWNSTREAM OF WINTERIZATIONASSEMBLY.2. INTENT OF ASSEMBLY IS TO WINTERIZE MASTER VALVE AND FLOW SENSOR.ABCDEFGHIJKLMNOA.VALVE MARKER OR PVC PIPE CAPB.FINISH GRADE/TOP OF MULCHC.2" PVC CL 200 PIPE (LENGTH AS REQUIRED)D.12" STANDARD VALVE BOX WITH COVERE.QUICK COUPLING VALVEF.COPPER MALE ADAPTERG.BRICK (1 OF 4)H.COPPER PIPE (SIZED TO MATCH NOMINALQUICK COUPLING VALVE INLET SIZE,LENGTH AS REQUIRED)I.COPPER TEEJ.COPPER FEMALE ADAPTERK.PVC MAINLINE PIPEL.SCH 40 PVC MALE ADAPTERM.COPPER PIPE (LENGTH AS REQUIRED)N.CURB STOP VALVE WITH COPPER SERVICE,THREAD BOTH ENDSO.COPPER PIPE AT FROST FREE DEPTH FROMPOINT-OF-CONNECTIONP.3" MIN. DEPTH OF 3/4" WASHED GRAVELP2MASTER VALVEASSEMBLYN.T.S.3FLOW SENSORASSEMBLYN.T.S.NOTES:1. USE VALVE BOX EXTENSION AS NECESSARY TO ACHIEVE MINIMUM DIMENSIONSABOVE ASSEMBLY.2. NOMINAL SIZE OF ALL COMPONENTS ARE TO BE THE SAME NOMINAL SIZE AS THESOLENOID VALVE (SIZED AS SHOWN).3. INSTALL FILTER FABRIC AROUND EXTERIOR OF VALVE BOX. USE DUCT TAPE TOSECURE FABRIC TO PIPE AND VALVE BOX.4. DO NOT CUT OUT ENDS OF VALVE BOX UNNECESSARILY.5. POSITION VALVE BOX OVER VALVE TO ALLOW ACCESS TO SOLENOID.6. INSTALL SO THAT NO GRAVEL IS IN CONTACT WITH VALVE ASSEMBLY.ABCDEFGHIJKLA.TRACING WIREB.FINISH GRADE/TOP OF MULCHC.STANDARD RECTANGULAR VALVEBOX W/ EXTENSIOND.WIRE SPLICE, TYPICALE.DECODERF.SOLENOID VALVEG.TWO-WIRE CABLEH.PVC MAINLINEI.BRICK (1 OF 4)J.FILTER FABRICK.3" MINIMUM DEPTH OF 3/4"WASHED GRAVELL.PVC SCH 40 MALE ADAPTERLMFABCDEFGHIJKA.TRACING WIREB.12" VALVE BOX WITHCOVERC.FINISH GRADE/TOP OFMULCHD.SENSOR DECODERE.WIRE SLICE, TYPICALF.FLOW SENSORG.TWO WIRE CABLEH.FILTER FABRICI.PVC PIPEJ.BRICK (1 OF 4)K.3" MINIMUM DEPTH OF3/4" WASHED GRAVELNOTES:1. ALLOW 10 PIPE DIAMETERS UPSTREAM AND 5 PIPE DIAMETERSDOWNSTREAM OF STRAIGHT RUN OF PIPE TO ACHIEVE PROPER FLOWREGIME.2. INSTALL FILTER FABRIC AROUND EXTERIOR OF VALVE BOX. USE DUCTTAPE TO SECURE FABRIC TO PIPE AND VALVE BOX.3. DO NOT CUT OUT ENDS OF VALVE BOX UNNECESSARILY.4. INSTALL SO THAT GRAVEL IS ONLY IN CONTACT WITH BOTTOM OFSENSOR ASSEMBLY.4ISOLATION GATE VALVEASSEMBLYN.T.S.5BLOW OUT ASSEMBLYN.T.S.NOTE:1. FURNISH NOMINAL PIPE AND FITTING SIZES IDENTICAL WITH NOMINALTAP SIZE UNLESS OTHERWISE NOTED.ABCDEFGHIJKLKA.12" STANDARD VALVE BOX WITH COVERB.FINISH GRADE/TOP OF MULCHC.1" BRONZE BALL VALVE FEMALETHREADED ENDSD.1" COPPER MALE ADAPTERE.1" COPPER PIPE (LENGTH AS REQUIRED)F.3" MIN. DEPTH OF 3/4" WASHED GRAVELG.BRICK (1 OF 4)H.COPPER FEMALE THREADED ADAPTERI.SCH. 40 PVC MALE THREADED ADAPTERJ.PVC MAINLINEK.COPPER PIPEL.COPPER TEEHIJBNOTE:1. NOMINAL SIZE OF GATE VALVE TO MATCH NOMINAL MAINLINE SIZE.ABCDEFGHIA.FINISH GRADE/TOP OF MULCHB.10" ROUND VALVE BOX WITH COVERC.6" PVC CL 200 PIPE (LENGTH ASREQUIRED)D.3" MINIMUM DEPTH OF 3/4" WASHEDGRAVELE.BRICK (1 OF 2)F.THREADED BRONZE GATE VALVEWITH SOLID WEDGE, NON-RISINGSTEMG.PVC MAINLINEH.PVC SCH 40 MALE ADAPTER (1 OF 2)I.TRACING WIRE6QUICK COUPLING VALVEASSEMBLYN.T.S.QABCDEFGHIA.FINISH GRADE/TOP OF MULCHB.QUICK-COUPLING VALVEC.10" ROUND VALVE BOX WITH COVERD.HARCO QUICK COUPLER ANCHORE.PVC SCH 80 TOE NIPPLE (LENGTH ASREQUIRED)F.BRICK (1 OF 2)G.PRE-FABRICATED UNITIZED SWINGJOINT 1" MIPT INLET X SOC OUTLETH.TEE OR EL: SEE SPECIFICATIONSFOR MATERIALSI.PVC MAINLINE PIPEJ.TRACING WIRENOTES:1. FURNISH FITTINGS AND PIPING NOMINALLY SIZED IDENTICAL TO NOMINALQUICK COUPLING VALVE INLET SIZE.2. INSTALLATION HEIGHT OF QUICK COUPLER VALVE IN VALVE BOX MUSTASSURE PROPER OPERATION OF QUICK COUPLER KEY.3. INSTALL SWING JOINT LAY ARM BETWEEN 30ƒ AND 45ƒ OF LATERAL PIPEIN ORDER TO ABSORB DOWNWARD IMPACT.J Sheet Date:Sheet Number:Drawing Name:Drawn b\:Designed b\:RevisionsChecked b\:Project Number:Project: Client:1603 Oakridge Drive FortCollins, CO 80525(970) 223-7577www.bhadesign.comLandscape ArchitectureUrban DesignPlanning5041 TECHNOLOGY PARKWAY FDP MAVD 2723 SOUTH STATE ST, STE. 250 ANN ARBOR MI, 48104JK/SBJK/SBRBPDR2000114/27/2022IR3.1NOT FOR CONSTRUCTIONPRELIMINARY DESIGNNOT FOR CONSTRUCTIONPRELIMINARY DESIGNNOT FOR CONSTRUCTIONNOT FOR CONSTRUCTIONIRRIGATIONDETAILS1AIR VACUUM RELIEF VALVEASSEMBLYN.T.S.3REMOTE CONTROL VALVEASSEMBLYN.T.S.4POP-UP SPRAY SPRINKLERASSEMBLYN.T.S.5POP-UP ROTOR SPRINKLERASSEMBLYN.T.S.ABCDEFGHIJA.JUMBO VALVE BOX WITH EXTENSION ANDCOVER (HEIGHT AS REQUIRED)B.FINISH GRADE/TOP OF MULCHC.AIR VACUUM RELIEF VALVED.PVC SCH 80 NIPPLE (LENGTH AS REQUIRED)E.PVC SCH 40 BALL VALVE (SIZE 1")F.PVC SCH 80 NIPPLE (LENGTH AS REQUIRED)G.3" MINIMUM DEPTH OF 3/4" WASHED GRAVELH.BRICK (1 OF 4)I.PVC MAINLINE PIPEJ.TEE OR EL: SEE SPECIFICATIONS FORMATERIALSK.TRACING WIRENOTES:1. OPEN BALL VALVE IN ASSEMBLY 1/4 TURN UNTIL IRRIGATION SYSTEM IS FULLY CHARGED WITH WATER.2. CLOSE VALVE DURING WINTERIZATION AND OPEN 1/2 TURN AFTER WINTERIZATION OF SYSTEM TOPROTECT VALVE DURING FREEZING WEATHER.3. REPLACE PVC BALL VALVE WITH BRASS BALL VALVE IN THE EVENT AN AIR VACUUM RELIEF VALVE WITHMALE INLET IS USED.KNOTES:1. USE VALVE BOX EXTENSION AS NECESSARY TO ACHIEVE MINIMUM DIMENSIONS ABOVE ASSEMBLY.2. NOMINAL SIZE OF ALL COMPONENTS ARE TO BE THE SAME NOMINAL SIZE AS THE SOLENOID VALVE(SIZED AS SHOWN).3. INSTALL FILTER FABRIC AROUND EXTERIOR OF VALVE BOX. USE DUCT TAPE TO SECURE FABRIC TOPIPE AND VALVE BOX.4. TRANSITION TO PROPER LATERAL PIPE BURIAL DEPTH USING 45° ELBOW FITTINGS DOWNSTREAMOF REMOTE CONTROL VALVE ASSEMBLY.5. DO NOT CUT OUT ENDS OF VALVE BOX UNNECESSARILY.6. POSITION VALVE BOX OVER VALVE TO ALLOW ACCESS TO SOLENOID AND PROPER OPERATION OFBALL VALVE.7. COIL 3-FEET OF WIRE FOR EACH DECODER FOR SERVICE PURPOSES.ABCDEFGIKLMNOPQRSTUVJHA.DECODERB.WIRE FROM DECODER TO VALVE SEESPECIFICATIONSC.PVC BALL VALVED.REMOTE CONTROL VALVEE.WIRE CONNECTOR FROM TWO-WIRECABLE TO DECODER (1 OF 2)F.CHRISTY ID TAGG.FINISH GRADEH.PVC SCH 80 CLOSE NIPPLEI.WIRE CONNECTOR FROM DECODER TOSOLENOID VALVE (1 OF 2)J.PVC SCH 40 MALE ADAPTERK.12" STANDARD VALVE BOX WITH COVERL.PVC LATERAL PIPEM.FILTER FABRICN.PVC SCH 80 TOE NIPPLE (LENGTH ASREQUIRED)O.PVC SCH 40 ELP.PVC SCH 40 PIPE (LENGTH ASREQUIRED)Q.BRICK (1 OF 4)R.PVC MAINLINES.TWO-WIRE CABLET.3" MINIMUM DEPTH OF 3/4" WASHEDGRAVELU.TEE OR EL: SEE SPECIFICATIONS FORMATERIALSV.PVC SCH 80 TOE NIPPLE (LENGTH ASREQUIRED, HIDDEN) AND PVC SCH 40EL6POP-UP BUBBLERASSEMBLYN.T.S.CDEFA.FINISH GRADE/TOP OFMULCHB.POP-UP SPRAYSPRINKLERC.SWING PIPE, 12" LENGTHD.1/2" MALE NPT [ BARB ELE.PVC SCH 40 TEE OR ELF.PVC LATERAL PIPEDBA6"BCDEA.FINISH GRADEB.POP-UP ROTORSPRINKLERC.PRE-FABRICATED SWINGJOINT MIPT INLET [ MIPTOUTLETD.PVC LATERAL PIPEE.PVC SCH 40 TEE OR EL30°to 45°A6"ROOT BALLABCDEFGHIA.WATER BASINB.STREAM BUBBLERC.FINISH GRADED.POP-UP SPRAY SPRINKLER W/BUBBLERE.1/2" MALE NPT [ 0.490" BARB ELF.SWING PIPE, 12" LENGTHG.1/2" MALE NPT [ 0.49" BARB ELH.PVC LATERAL PIPEI.PVC SCH. 40 TEE OR EL2SUBMETERASSEMBLYN.T.S.WINLETNOTES:1. USE VALVE BOX EXTENSION ASNECESSARY TO ACHIEVE MINIMUMDIMENSIONS ABOVE AND BELOWASSEMBLY.2. INSTALL METER ACCORDING TOMANUFACTURER SRECOMMENDATIONS.3. PROVIDE MINIMUM OF 5X PIPEDIAMETER STRAIGHT RUN LENGTHUPSTREAM AND DOWNSTREAM OFMETER.ABCDEFGHIA.JUMBO VALVE BOXB.FINISH GRADE/TOP OF MULCHC.METERD.THREADED COMPANION FLANGE (1OF 2)E.PVC MALE ADAPTER (1 OF 2)F.PVC MAINLINE PIPEG.BRICK (1 OF 4)H.GEOTEXTILE FABRICI.2.0 CUBIC FEET MINIMUM DEPTH OF3/4" WASHED GRAVEL Sheet Date:Sheet Number:Drawing Name:Drawn b\:Designed b\:RevisionsChecked b\:Project Number:Project: Client:1603 Oakridge Drive FortCollins, CO 80525(970) 223-7577www.bhadesign.comLandscape ArchitectureUrban DesignPlanning5041 TECHNOLOGY PARKWAY FDP MAVD 2723 SOUTH STATE ST, STE. 250 ANN ARBOR MI, 48104JK/SBJK/SBRBPDR2000114/27/2022IR3.2NOT FOR CONSTRUCTIONPRELIMINARY DESIGNNOT FOR CONSTRUCTIONPRELIMINARY DESIGNNOT FOR CONSTRUCTIONNOT FOR CONSTRUCTIONIRRIGATIONDETAILS1DRIP REMOTE CONTROL VALVEASSEMBLYN.T.S.2ZONE CONTROL VALVEASSEMBLYN.T.S.3TYPICAL DRIP LAYOUTDETAILN.T.S.4IRRIGATION CONTROLLER ASSEMBLYN.T.S.5CONTROLLER GROUNDINGDETAILN.T.S.ABCDEFHQKLMNOPQRSTIGJA.PRESSURE REGULATING FILTERB.WIRE FROM DECODER TO VALVESEE SPECIFICATIONSC.DECODERD.WIRE CONNECTOR FROMTWO-WIRE CABLE TO DECODER (1OF 2)E.CHRISTY I.D. TAGF.JUMBO VALVE BOX WITH COVERG.PVC BALL VALVEH.FINISH GRADE/TOP OF MULCHI.PVC SCH 80 NIPPLEJ.3" MINIMUM DEPTH OF 3/4" WASHEDGRAVELK.REMOTE CONTROL VALVEL.PVC SCH 80 TOE NIPPLEM.PVC SCH 40 ELN.PVC SCH 40 PIPE (TYPICAL)(LENGTH AS REQUIRED)O.FILTER FABRICP.BRICK (1 OF 4)Q.MANIFOLD/DRIP LATERAL. SEENOTE 8.R.TWO-WIRE CABLES.TEE OR EL: SEE SPECIFICATIONSFOR MATERIALST.PVC SCH 80 TOE NIPPLE (LENGTHAS REQUIRED, HIDDEN) AND PVCSCH 40 ELNOTES:1. USE VALVE BOX EXTENSION AS NECESSARY TO ACHIEVE MINIMUM DIMENSIONSABOVE ASSEMBLY.2. NOMINAL SIZE OF ALL COMPONENTS ARE TO BE THE SAME NOMINAL SIZE ASTHE SOLENOID VALVE (SIZED AS SHOWN).3. INSTALL FILTER FABRIC AROUND EXTERIOR OF VALVE BOX. USE DUCT TAPE TOSECURE FABRIC TO PIPE AND VALVE BOX.4. TRANSITION TO PROPER LATERAL PIPE BURIAL DEPTH USING 45ƒ ELBOWFITTINGS DOWNSTREAM OF REMOTE CONTROL VALVE ASSEMBLY.5. DO NOT CUT OUT ENDS OF VALVE BOX UNNECESSARILY.6. POSITION VALVE BOX OVER VALVE TO ALLOW ACCESS TO SOLENOID, ANDPROPER OPERATION OF BALL VALVE.7. COIL 3-FEET OF WIRE FOR EACH DECODER FOR SERVICE PURPOSES.8. IN CASES OF DIRECT DRIP LATERAL PIPE CONNECTION INSTALL SCH. 40 PVCBARB FITTING TO PRESSURE REGULATING BASKET. SECURE CONNECTION WITHSTAINLESS STEEL PINCH CLAMPS.9. SEE DECODER GROUNDING SCHEMATIC FOR ADDITIONAL DECODER GROUNDINGINFORMATION.ABCDEFGHIJKLMNOA.6" ROUND VALVE BOX WITHCOVERB.FINISH GRADE/TOP OF MULCHC.PVC SCH. 40 ELD.PVC BALL VALVEE.PVC SCH. 40 TRANSITIONNIPPLE (MIPT[MHT)F.COMPRESSION[FEMALE HOSESWIVEL ADAPTERG.DRIP LATERAL PIPINGH.3" MINIMUM DEPTH OF 3/4"WASHED GRAVELI.BRICK (1 OF 2)J.PVC SCH 80 NIPPLE (LENGTHAS REQUIRED, 1 OF 2)K.PVC SCH 40 ELL.PVC SCH 40 STREET EL (1 OF 2)M.PVC DRIP MANIFOLD PIPEN.PVC SCH 40 TEE OR ELO.PVC SCH 80 NIPPLE (LENGTHAS REQUIRED)XXXXXXXXXXXXXXXXXXXXXXXXNOTES:1. EMITTERS SHALL BE LOCATED IMMEDIATELY ADJACENT TOPERENNIALS AND AT THE OUTSIDE PERIMETER OF THEPLANTING PIT OF ALL SHRUBS AND TREES.2. INSTALL FOUR 1 GPH EMITTERS PER DECIDUOUS TREE.3. INSTALL THREE 1 GPH EMITTER PER CONIFEROUS TREE.4. INSTALL TWO 1 GPH EMITTER PER SHRUB.5. INSTALL ONE 1 GPH EMITTER PER PERENNIAL.ABCDEFA.DRIP LATERAL PIPEB.CONIFEROUS TREEC.DECIDUOUS TREED.EMITTERE.SHRUBF.PERENNIAL6DECODER GROUNDINGSCHEMATICN.T.S.ABCDEA.IRRIGATION CONTROLLER WALLMOUNTB.3" PVC SCH 40 CONDUIT ANDFITTINGSC.JUNCTION BOXD.TWO WIRE CABLE TO REMOTECONTROL VALVESE.1" PVC SCH 40 CONDUIT ANDFITTINGS TO POWER SUPPLYWALLPLAN VIEWA.IRRIGATION CONTROLLER ASSEMBLYB.UL LISTED 5/8" X 10' COPPER-CLADGROUNDING RODC.UL LISTED 4" X 8' COPPER GROUNDING PLATED.10" ROUND VALVE BOX WITH COVERE.BRONZE GROUND ROD CLAMP OR CADWELDCONNECTION: PAIGE ELECTRICF.3" MINIMUM DEPTH OF 3/4" WASHED GRAVELG.BRICK (1 OF 4)H.#6 AWG INSULATED SOLID COPPER WIRE. NOSHARP BENDS.I.SPHERE OF INFLUENCEJ.EARTH CONTACT MATERIAL, POWERSET© ORPOWERFILL© DEPENDING ON SOIL CONDITIONSK.FINISH GRADEACB8'10'11'II30" MINIMUM12"SECTION VIEWHHHBCJDGFENOTES:1.CONNECT ALL #6 AWG WIRES INSIDE THECONTROLLER. CONNECT ONE WIRE TOTHE CONTROLLER GROUND LUG ANDUSE A #4 SPLIT BOLT TO CONNECT ALLWIRES TOGETHER.2.EARTH CONTACT MATERIAL MUSTCOMPLETELY COVER THE WELD JOINTON THE GROUND PLATE.KAA.TWO-WIRE CABLEB.VALVE BOX (10" ROUND OR AS NECESSARY)C.REMOTE CONTROL VALVED.5/8" X 8' U.L. LISTED GROUND RODE.DECODERF.LINE SURGE PROTECTORG.BARE AWG #10 COPPER WIREH.3M DBR/Y-6 CONNECTIONI.BARE COPPER CONNECTION ("CADWELD")J.REMOTE CONTROL VALVE ASSEMBLY500' MAX OR 5 DECODERSBETWEEN GROUND POINTSWHICHEVER IS FIRSTGROUND ALL DEAD ENDS25' AND LONGERSPHERE OF INFLUENCEWIRE PATHOUTSIDE SPHEREOF INFLUENCE(10' MIN.)GROUND TWO WIRE CABLE NEARCONTROLLER PER MANUFACTURER'SGUIDELINESNOTES:1. ALL WIRE CONNECTION SHALL BE MADE WITH APPROVED CONNECTORS.2. MAKE ALL WIRE SPLICES IN VALVE BOXES.3. LEAVE A MINIMUM OF 5' EXTRA WIRE AT ALL SPLICE POINTS.4. TEST EARTH TO GROUND RESISTANCE AT ALL GROUND POINTS.5. EARTH TO GROUND RESISTANCE MUST MEET OR EXCEED MANUFACTURER REQUIREMENTS.6. INSTALL ALL GROUND ASSEMBLIES IN VALVE BOXES.7. INSTALL GROUNDING EQUIPMENT AS INDICATED ON THE IRRIGATION DOCUMENTS AND ASRECOMMENDED BY THE MANUFACTURER.CDAJBEGHFIB Sheet Date:Sheet Number:Drawing Name:Drawn b\:Designed b\:RevisionsChecked b\:Project Number:Project: Client:1603 Oakridge Drive FortCollins, CO 80525(970) 223-7577www.bhadesign.comLandscape ArchitectureUrban DesignPlanning5041 TECHNOLOGY PARKWAY FDP MAVD 2723 SOUTH STATE ST, STE. 250 ANN ARBOR MI, 48104JK/SBJK/SBRBPDR2000114/27/2022IR3.3NOT FOR CONSTRUCTIONPRELIMINARY DESIGNNOT FOR CONSTRUCTIONPRELIMINARY DESIGNNOT FOR CONSTRUCTIONNOT FOR CONSTRUCTIONIRRIGATIONDETAILS1WIRE SPLICEDETAILN.T.S.2RAIN SENSORASSEMBLYN.T.S.3TRENCHDETAILN.T.S.4SLEEVEDETAILN.T.S.5TRACING WIREDETAILN.T.S.1.2.3.4.1/2"5.NOTE:1. VISUALLY CHECK THAT CONNECTOR IS BELOW LOCKING "FINGERS".1. STRIP ENDS OF WIRE2. SECURE WIRES INTO WIRE NUT3. INSERT WIRE NUT INTO GEL-FILLEDTUBE4. POSITION WIRES INTO CHANNELS5. CLOSE SPLICE KIT FOR SECUREDSEAL-WR2WIRELESS SENSORNOTES:1. MOUNT RAIN/FREEZE SENSOR IN SUITABLE LOCATION ON BUILDING EAVE OR WALL PERMANUFACTURER S INSTRUCTIONS.2. CONNECT INTERFACE TO CONTROLLER PER MANUFACTURER S GUIDELINES.3. CONFIRMATION NOTE: ENSURE WIRELESS COMMUNICATIONS OPERATE BETWEEN SENSORAND INTERFACE UNIT PRIOR TO INSTALLATION. IF WIRELESS COMMUNICATIONS ARE NOTSUFFICIENT SUBSTITUTE WIRELESS SENSOR FOR A WIRED SENSOR (HUNTER MINI-CLIK).INCLUDE HUNTER STAINLESS STEEL ENCLOSURE SG-MC AND NECESSARY MOUNTINGHARDWARE FOR WIRED SENSOR. INSTALL 1-INCH CONDUIT IF WIRED SENSOR ISRE4UIRED.ABCDEA.EAVE OR WALLB.MOUNTING BRACKETC.RAIN/FREEZE SENSOR INTERFACED.RAIN/FREEZE SENSORE.IRRIGATION CONTROLLER ASSEMBLYRABCDEFGA.WARNING TAPEB.FINISH GRADEC.BACKFILLD.LATERAL/MANIFOLD PIPEE.TWO-WIRE CABLEF.MAINLINE PIPEG.TRACING WIREREFER TOSPECIFICATIONSREFER TOSPECIFICATIONS12" MINIMUMNOTE:1. INSTALL SLEEVE SO THAT ITS LOWEST ELEVATION OCCURS ATONE OR BOTH ENDS - NOT ALONG ITS LENGTH.ABCDA.FINISHED GRADE OF PAVEDSURFACEB.SLEEVE FOR LATERAL PIPEC.SLEEVE FOR MAINLINE PIPED.SLEEVE FOR WIRINGSLEEVE SIZING SCHEDULEFINISHED GRADEELEVATION VIEWPLAN VIEWNOTES:1. COPPER TRACING WIRE WILL START AT THE MASTERVALVE AND WILL BE ROUTED WITH ALL MAINLINE PIPE.2. SPLICE TRACING WIRE IN IRRIGATION MAINLINECOMPONENT VALVE BO;ES WHEN POSSIBLE,OTHERWISE, PLACE SPLICE IN SEPARATE VALVE BO;.ABCDEFGHA.10" ROUND VALVE BO;B.INSTALL TRACING WIRE TO THE TOP OF VALVE BO;C.WATER PROOF CONNECTION (SEE SPECIFICATIONS)D.PIPE SLEEVE SEE VALVE DETAILE.TAPE COPPER WIRE TO TOP OF PIPE EVERY 10 FT.F.CONTINUOUS LOOP COPPER TRACING WIRE (SEESPECIFICATIONS)G.PVC PIPEH.VALVE (TYPICAL) Sheet Date:Sheet Number:Drawing Name:Drawn b\:Designed b\:RevisionsChecked b\:Project Number:Project: Client:1603 Oakridge Drive FortCollins, CO 80525(970) 223-7577www.bhadesign.comLandscape ArchitectureUrban DesignPlanning5041 TECHNOLOGY PARKWAY FDP MAVD 2723 SOUTH STATE ST, STE. 250 ANN ARBOR MI, 48104JK/SBJK/SBRBPDR2000114/27/2022IR3.4NOT FOR CONSTRUCTIONPRELIMINARY DESIGNNOT FOR CONSTRUCTIONPRELIMINARY DESIGNNOT FOR CONSTRUCTIONNOT FOR CONSTRUCTIONIRRIGATIONDETAILS1HYDRAULICCALCULATIONN.T.S.2ANNUAL WATER USECHARTN.T.S.3IRRIGATION SCHEDULEN.T.S.NOTES:1. THE PEAK SEASON RUN TIME HAS BEEN CALCULATED ASSUMING AN IRRIGATION EFFICIENCY OF 70% AND A PEAK SEASON ETo OF 0.21INCHES/DAY. THE CROP COEFFICIENT IS ASSUMED TO BE 0.8 FOR TURF AND 0.6 FOR SEED.2. THE POC SIZE WAS CALCULATED FOR A 8 HR X 6 DAYS/WEEK IRRIGATION WINDOW TO IRRIGATE THE TURF GRASS AND SEED.3. ADJUST INDIVIDUAL STATION RUN TIMES AS NECESSARY TO ACCOMMODATE TURF/PLANT ESTABLISHMENT, TURF TYPE, TURF/PLANT SOLAREXPOSURE, SOIL TYPES, WIND, AND SLOPE.4. ADJUST DRIP RUN TIMES AS NECESSARY FOR PLANT ESTABLISHMENT. RECORD RUN TIMES ON THE RECORD DRAWINGS.5. BLANK ITEMS TO BE COMPLETED ON AS-BUILT DRAWINGS BY CONTRACTOR. SOIL TYPE - CLAY, SAND, LOAM, ETC. SLOPE - NONE, GENTLE, MILD,STEEP. MICROCLIMATE - SHADE, PARTIAL SUN/SHADE, FULL SUN.6. PROVIDE LAMINATED COPY OF PEAK IRRIGATION SCHEDULE WITHIN IRRIGATION CONTROLLER ENCLOSURE.UNDERDEVELOPMENT