HomeMy WebLinkAboutPOWERHOUSE 2 - PDP220006 - SUBMITTAL DOCUMENTS - ROUND 1 - SITE PLANSheet Number:Project Number:Project:
Client:1603 Oakridge Drive, Suite 100Fort Collins, CO 80525p. (970) 223-7577www.bhadesign.comLandscape ArchitectureUrban DesignMaster PlanningC:\USERS\MOLLIESIMPSON\ONEDRIVE - BHADESIGN\PROJECTS\POWERHOUSE 2\DRAWINGS\ACAD\PDP\DWG\2057_SITE PLAN.DWGPlot Date:4/19/2022 2:35 PM Plotted By: Mollie BredehoftDate Created:4/13/2022
Produced by:Date:Revision:S0Date:SITE PLAN
POWERHOUSE 2
CLIMATE SOLUTIONS CAMPUS
PRELIIMINARY DESIGN REVIEW04/13/20222057SHEET INDEXSHEET S0COVER SHEETPLANNING CERTIFICATE______________________________________________ APPROVED BY THE DIRECTOR OF COMMUNITY DEVELOPMENT AND NEIGHBORHOOD SERVICES OF THE CITY OF FORTCOLLINS, COLORADO ON THIS _____ DAY OF__________________, 20_____,Director SignatureOWNER'S CERTIFICATETHE UNDERSIGNED DOES/DO HEREBY CERTIFY THAT I/WE ARE THE LAWFUL OWNERS OF THE REAL PROPERTYDESCRIBED ON THIS SITE PLAN AND DO HEREBY CERTIFY THAT I/WE ACCEPT THE CONDITIONS AND RESTRICTIONSSET FORTH ON SAID SITE PLAN.______________________________________________ Owner (Signed)______________________________________________ DateTHE FOREGOING INSTRUMENT WAS ACKNOWLEDGED BEFORE ME THIS _____ DAY OF__________________ A.D., 20_____,BY________________________________________________(print name)AS ________________________________________________MY COMMISSION EXPIRES: ________________________________________________WITNESS MY HAND AND OFFICIAL SEAL.______________________________________________ Notary Public______________________________________________ AddressPOWERHOUSE 2 CLIMATE SOLUTIONS CAMPUS NOT TO SCALEVICINITY MAPSHEET S1 SITE PLAN SHEETSSHEET L1 - L3LANDSCAPE PLAN SHEETSSHEET M1TREE MITIGATION SHEETSLAND USE DATAFIVE (5) STORIESNUMBER OF BUILDING STORIESEXISTING ZONING DOWNTOWN INNOVATION SUBDISTRICTON-STREET PARKING SPACES: OFF-STREET PARKING SPACES:162 (155 STANDARD, 7 ACCESSIBLE) 8 A PARCEL OF LAND LOCATED IN THE SOUTHWEST QUARTER OF SECTION 1, TOWNSHIP 7 NORTH,RANGE 69 WEST OF THE 6TH P.M., CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO1.REFER TO FINAL UTILITY PLANS FOR EXACT LOCATIONS AND CONSTRUCTION INFORMATION FOR STORM DRAINAGE STRUCTURES, UTILITY MAINS AND SERVICES, PROPOSED TOPOGRAPHY, STREET IMPROVEMENTS.2.REFER TO THE SUBDIVISION PLAT AND UTILITY PLANS FOR EXACT LOCATIONS, AREAS AND DIMENSIONS OF ALL EASEMENTS, LOTS, TRACTS, STREETS, WALKS AND OTHER SURVEY INFORMATION.3.THE PROJECT SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE FINAL PLANS. AMENDMENTS TO THE PLANS MUST BE REVIEWED AND APPROVED BY THE CITY PRIOR TO THE IMPLEMENTATION OF ANY CHANGESTO THE PLANS.4.ALL ROOFTOP AND GROUND MOUNTED MECHANICAL EQUIPMENT MUST BE SCREENED FROM VIEW FROM ADJACENT PROPERTY AND PUBLIC STREETS. IN CASES WHERE BUILDING PARAPETS DO NOT ACCOMPLISHSUFFICIENT SCREENING, THEN FREE-STANDING SCREEN WALLS MATCHING THE PREDOMINANT COLOR OF THE BUILDING SHALL BE CONSTRUCTED. OTHER MINOR EQUIPMENT SUCH AS CONDUIT, METERS ANDPLUMBING VENTS SHALL BE SCREENED OR PAINTED TO MATCH SURROUNDING BUILDING SURFACES.5.ALL CONSTRUCTION WITH THIS DEVELOPMENT PLAN MUST BE COMPLETED IN ONE PHASE UNLESS A PHASING PLAN IS SHOWN WITH THESE PLANS.6.ALL EXTERIOR LIGHTING PROVIDED SHALL COMPLY WITH THE FOOT-CANDLE REQUIREMENTS IN SECTION 3.2.4 OF THE LAND USE CODE AND SHALL USE A CONCEALED, FULLY SHIELDED LIGHT SOURCE WITH SHARPCUT-OFF CAPABILITY SO AS TO MINIMIZE UP-LIGHT, SPILL LIGHT, GLARE AND UNNECESSARY DIFFUSION.7.SIGNAGE AND ADDRESSING ARE NOT PERMITTED WITH THIS PLANNING DOCUMENT AND MUST BE APPROVED BY SEPARATE CITY PERMIT PRIOR TO CONSTRUCTION. SIGNS MUST COMPLY WITH CITY SIGN CODEUNLESS A SPECIFIC VARIANCE IS GRANTED BY THE CITY.8.FIRE HYDRANTS MUST MEET OR EXCEED POUDRE FIRE AUTHORITY STANDARDS. ALL BUILDINGS MUST PROVIDE AN APPROVED FIRE EXTINGUISHING SYSTEM.9.ALL BIKE RACKS PROVIDED MUST BE PERMANENTLY ANCHORED.10.ALL SIDEWALKS AND RAMPS MUST CONFORM TO CITY STANDARDS. ACCESSABLE RAMPS MUST BE PROVIDED AT ALL STREET AND DRIVE INTERSECTIONS AND AT ALL DESIGNATED ACCESSABLE PARKING SPACES.ACCESSABLE PARKING SPACES MUST SLOPE NO MORE THAN 1:48 IN ANY DIRECTION. ALL ACCESSIBLE ROUTES MUST SLOPE NO MORE THAN 1:20 IN DIRECTION OF TRAVEL AND WITH NO MORE THAN 1:48 CROSSSLOPE.11.COMMON OPEN SPACE AREAS AND LANDSCAPING WITHIN RIGHT OF WAYS, STREET MEDIANS, AND TRAFFIC CIRCLES ADJACENT TO COMMON OPEN SPACE AREAS ARE REQUIRED TO BE MAINTAINED BY THEPROPERTY OWNER OF THE COMMON AREA. THE PROPERTY OWNER IS RESPONSIBLE FOR SNOW REMOVAL ON ALL ADJACENT STREET SIDEWALKS AND SIDEWALKS IN COMMON OPEN SPACE AREAS.12.DESIGN AND INSTALLATION OF ALL PARKWAY/TREE LAWN AND MEDIAN AREAS IN THE RIGHT-OF-WAY SHALL BE IN ACCORDANCE WITH CITY STANDARDS. UNLESS OTHERWISE AGREED TO BY THE CITY WITH THE FINALPLANS, ALL ONGOING MAINTENANCE OF SUCH AREAS IS THE RESPONSIBILITY OF THE OWNER/DEVELOPER.13.THE PROPERTY OWNER FOR EACH RESIDENTIAL LOT IS RESPONSIBLE FOR SNOW REMOVAL ON ALL STREET SIDEWALKS ADJACENT TO EACH RESIDENTIAL LOT.14.PRIVATE CONDITIONS, COVENANTS, AND RESTRICTIONS (CC&R'S), OR ANY OTHER PRIVATE RESTRICTIVE COVENANT IMPOSED ON LANDOWNERS WITHIN THE DEVELOPMENT, MAY NOT BE CREATED OR ENFORCEDHAVING THE EFFECT OF PROHIBITING OR LIMITING THE INSTALLATION OF XERISCAPE LANDSCAPING, SOLAR/PHOTO-VOLTAIC COLLECTORS (IF MOUNTED FLUSH UPON ANY ESTABLISHED ROOF LINE), CLOTHES LINES(IF LOCATED IN BACK YARDS), ODORCONTROLLED COMPOST BINS, OR WHICH HAVE THE EFFECT OF REQUIRING THAT A PORTION OF ANY INDIVIDUAL LOT BE PLANTED IN TURF GRASS.15.ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THISPROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCEOF THE FIRST CERTIFICATE OF OCCUPANCY.16.FIRE LANE MARKING: A FIRE LANE MARKING PLAN MUST BE REVIEWED AND APPROVED BY THE FIRE OFFICIAL PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. WHERE REQUIRED BY THE FIRE CODEOFFICIAL, APPROVED SIGNS OR OTHER APPROVED NOTICES THAT INCLUDE THE WORDS NO PARKING FIRE LANE SHALL BE PROVIDED FOR FIRE APPARATUS ACCESS ROADS TO IDENTIFY SUCH ROADS OR PROHIBITTHE OBSTRUCTION THEREOF. THE MEANS BY WHICH FIRE LANES ARE DESIGNATED SHALL BE MAINTAINED IN A CLEAN AND LEGIBLE CONDITION AT ALL TIMES AD BE REPLACED OR REPAIRED WHEN NECESSARY TOPROVIDE ADEQUATE VISIBILITY.17.PREMISE IDENTIFICATION: AN ADDRESSING PLAN IS REQUIRED TO BE REVIEWED AND APPROVED BY THE CITY AND POUDRE FIRE AUTHORITY PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. UNLESSTHE PRIVATE DRIVE IS NAMED, MONUMENT SIGNAGE MAY BE REQUIRED TO ALLOW WAY-FINDING. ALL BUILDINGS SHALL HAVE ADDRESS NUMBERS, BUILDING NUMBERS OR APPROVED BUILDING IDENTIFICATIONPLACED IN A POSITION THAT IS PLAINLY LEGIBLE, VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY, AND POSTED WITH A MINIMUM OF SIX-INCH NUMERALS ON A CONTRASTING BACKGROUND. WHEREACCESS IS BY MEANS OF A PRIVATE ROAD AND THE BUILDING CANNOT BE VIEWED FROM THE PUBLIC WAY, A MONUMENT, POLE OR OTHER SIGN OR MEANS SHALL BE USED TO IDENTIFY THE STRUCTURE.SITE PLAN NOTES:PHASE GPROJECTBOUNDARYNOT TO SCALECONTEXT MAPLAKE CANALE VINE DRIVEN COLLEGE AVENUE
JEROME STREETPOUDRE RIVERWHITEWATER PARKPROPOSED ZONING DOWNTOWN INNOVATION SUBDISTRICT9,574 SF AMOUNT AND TYPE OF COMMERCIAL SPACE:106,233 SF4,236 SFOFFICE SPACELAB SPACERETAIL / LOCAL FOOD MARKET5,488 SFLOBBY / CORRIDORS8,025 SF (approx.)BUILDING SUPPORTPROJECT SIZE PROPOSED USECOMMERCIAL201,287 SQ FTNET SITE AREA153,000 SFBUILDING GROSS SQ FT19,144 SF (approx.)ELEVATOR AND STAIRS58,300 SQ FTPARKING AND DRIVE AREA17,911 SQ FTSTORM DETENTION AREALANDSCAPE AREA39,800 SQ FTPATIOS / UTILITY ENCLOSURES37,902 SQ FTBUILDING COVERAGE47,374 SQ FT216,622 SQ FT (4.97 ACRES)GROSS15,335 SQ FTEXISTING ROW0.76FLOOR AREA RATIOFIXED BIKE PARKING:28 COVERED BIKE PARKING (IN BUILDING):8
SWFGGUGEUGEUGEUGEUGEUDUDUDUDUDUDUDUDUDUDUDUDVAULTELECVAULTELECVAULTELECVAULTELECHYDELECELECVAULTELECHYDTVAULTF.O.VAULTF.O.F.O.DSSSSCONTROLIRRCONTROLIRRGASELECBRKRT SWWWWWWWWWWWWWWWWWWWWWWWWEEEEEEEEEEEEEEEEEEEEEEEEEE E E EEEEEEEFOFO FOFOFOFOFOFOFOFOFOFOFOFO FO FO FO FO FO FO FO FO FO FOGGGGGGGGGGGGWWWWWWWWWWWWFOFOFOFOFOFOFOFO
FOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTW W W W W W W WWWWWWWWWWWWWWWWWWWWWWWWWWWWFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOXXXXXXXGGGGGGGG GWEEEEEEFOFOFOFOFOFO
SSSSSSSSSSSSSSSSSSSSG G G G G G G G GEWWSWOWSSSS SSS SS SS SS
SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS
SS
SS
SS
SS
SS
SOHU OHU OHUD
SLTLN. COLLEGE AVENUEARTERIAL 4-LANE
JEROME STREET
COLLECTOR 2-LANEE. VINE DRIVEARTERIAL 2-LANEFL. TO FL.50'-1112"ROW. TO ROW.89'-912"POUDRE RIVER WHITEWATER PARKZONING: DOWNTOWN DISTRICTLAKE CANALCITY OF FORT COLLINSSTORMWATERZONING: DOWNTOWN DISTRICTJERMONE ST LLCZONING: COMMUNITYCOMMERCIALFIRST CASH FINANCIALSERVICESZONING: SERVICECOMMERCIAL DISTRICTPOWERHOUSE 2 CLIMATE SOLUTIONS CAMPUSPROPOSED BUILDING FOOTPRINTGROSS FLOOR AREA: 133,556 SFNUMBER OF STORIES: FIVE (5) STORIESBIKE PARKING(10 SPACES)BIKE PARKING(18 SPACES)WEST LOT(28) PARKING SPACES(2) ADA STALLSEAST LOT(127) PARKING SPACES(5) ADA STALLS27'15'-8"17'24'-012"17'8'8'8'8'24'17'
17'24'17'15'17'24'17'9'9'5'8'8'7'9'17'23'9'12'6'
6'
6'4'-6"12'DETENTION POND,RE: CIVILEXISTING TREES, TO REMAIN, TYP.SEE TREE MITIGATION PLANSOUTDOOR CLASSROOMPROPOSED TRAIL CONNECTIONPROPOSED TRAIL & BRIDGE(8) ON-STREETPARKING STALLS(4) ON-STREET PARKING STALLSADA RAMP, TYP.RE: CIVILSOLAR PARKING SHADESTRUCTURE, TYP.TRASH &RECYCLINGENCLOSURESERVICE YARDPROPERTY LINEROW LINEPROPERTY LINEROW LINE24'24'SITE RETAINING WALLS, TYP.ADA RAMPSTAIR CASESTAIR CASEPLANTING AREA, TYP.ADA RAMPSTAIR CASE10'23'-9"RAIN GARDENS, RE: LANDSCAPE & CIVILTABLES & CHAIRS, TYP.50' BUFFER ZONE, MEASUREDFROM EXISTING TREE DRIP-LINE39'-101
2"
66'-111
2"
58'-1012"CATENARY LIGHTS,STRING, AND POSTSLIGHTS, TYP.RE: LIGHTING PLANTREE WELL, TYP.STAIR CASESTAIR CASEADA RAMPADA RAMP, TYP.RE: CIVILMORAK KAREN LLCZONING: DOWNTOWN DISTRICTPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPA6'16'-512"20'-512"MODIFIED TYPEIII BUS STOPSTAIR CASERAIN GARDENS, RE:LANDSCAPE & CIVILADA RAMP, TYP.RE: CIVILADA RAMP, TYP.RE: CIVILACCESSIBLE AT GRADETRAIL CROSSINGRE: CIVILEXISTING TRAILACCESS POINTFLOODPLAINFLOODPLAINFLOODPLAINFLOODPLAINTOP OF DITCH,RE: CIVILEXISTING TREE DRIP-LINE42'-9"SITE RETAININGWALLS, TYP.TRANSFORMERSheet Number:Project Number:Project:
Client:1603 Oakridge Drive, Suite 100Fort Collins, CO 80525p. (970) 223-7577www.bhadesign.comLandscape ArchitectureUrban DesignMaster PlanningC:\USERS\MOLLIESIMPSON\ONEDRIVE - BHADESIGN\PROJECTS\POWERHOUSE 2\DRAWINGS\ACAD\PDP\DWG\2057_SITE PLAN.DWGPlot Date:4/19/2022 2:35 PM Plotted By: Mollie BredehoftDate Created:4/13/2022
Produced by:Date:Revision:S1Date:SITE PLAN
POWERHOUSE 2
CLIMATE SOLUTIONS CAMPUS
PRELIIMINARY DESIGN REVIEW04/13/20222057LEGENDTABLES & CHAIRSBIKE RACKSPICNIC TABLESPLANTING AREAPAGRAVEL PAVESOFT PATH