Loading...
HomeMy WebLinkAboutBLOOM FILING TWO - PDP220002 - SUBMITTAL DOCUMENTS - ROUND 2 - VARIANCE REQUEST 5265 Ronald Reagan Blvd., Suite 210 Johnstown, CO 80534 970.800.3300 • GallowayUS.com April 13, 2022 City of Fort Collins Engineering Department 281 North College Avenue Fort Collins, CO 80522 RE: Bloom Filing Two – Comet Street and Street I Minimum Separation Variance Dear Sophie Buckingham, Galloway, on behalf of Hartford Homes and in support of the Bloom Filing 2 project currently under review, is requesting a minimum separation variance for the driveway located west of the intersection of Crusader Street and Aria Way. A) Identification of the standard to be waived or varied and why the standard is unfeasible or is not in the public interest. The City of Fort Collins typically requires a minimum separation distance of 175’ from the driveway to the intersection, per Chapter 7 of the LCUASS standards, but, due to site-specific, spatial restraints, a separation distance of 175’ is not feasible. The site is spatially limited due to building widths and proximity to main roads necessary for fire access. B) Proposing Alternate Design. Identification of the proposed alternative design or construction criteria. Galloway is requesting a variance from 175’ of separation distance to a minimum of 100’ separation distance. C) A thorough description of the variance request including impact on capital and maintenance requirements, costs, and how the new design compares to the standard. Sight concerns with the variance have been addressed and discussed with the City, who were provided with a Sight Triangle Exhibit for review. This exhibit has been submitted with this application. There will be no impact to capital and maintenance requirements, or costs. The variance is requesting a reduction in separation distance by 75’ compared to the standard. D) Justification. The Professional Engineer must determine and state that the variance will not be detrimental to the public health, safety and welfare, will not reduce design life of the improvement nor cause the Local Entity additional maintenance costs. The proposed plan (as varied) must advance the public purpose of the standard sought to be varied equally well or better than would compliance with such standard. Client Name Project Name Date Galloway & Company, Inc. Page 2 of 2 The justification for this variance is the density and product styles used for this project to meet the affordability aspect proposed with the project. There is no impact on public health, safety, or welfare of the future homeowners. Sincerely, GALLOWAY Cristina Slater, PE Civil Project Engineer TinaSlater@GallowayUS.com cc: