HomeMy WebLinkAboutIMPALA MULTI-FAMILY - PDP220005 - SUBMITTAL DOCUMENTS - ROUND 1 - ARCHITECTURAL DETAILSIMPALA DRIVEIMPALA CIRCLE
BLDG B BLDG C
BLDG A
BLDG E BLDG DIMPALA DRIVEIMPALA CIRCLE
BLDG B BLDG C
BLDG A
BLDG E BLDG DIMPALA DRIVEIMPALA CIRCLE
BLDG B BLDG C
BLDG A
BLDG E BLDG D IMPALA DRIVEIMPALA CIRCLE
BLDG B BLDG C
BLDG A
BLDG E BLDG DIMPALA DRIVEIMPALA CIRCLE
BLDG B BLDG C
BLDG A
BLDG E BLDG DIMPALA DRIVEIMPALA CIRCLE
BLDG B BLDG C
BLDG A
BLDG E BLDG D
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY:REVIEWED BY:4/12/2022 5:52:04 PMA001
SOLAR ANALYSIS -
306 IMPALAIMPALA RENOVATIONS21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COMD CR
1" = 40'-0"1 SOLAR STUDY - DECEMBER 21 @ 10AM
1" = 40'-0"2 SOLAR STUDY - DECEMBER 21 @ 12PM
1" = 40'-0"3 SOLAR STUDY - DECEMBER 21 @ 2PM
1" = 40'-0"4 SOLAR STUDY - JUNE 21 @ 10AM
1" = 40'-0"5 SOLAR STUDY - JUNE 21 @ 12PM
1" = 40'-0"6 SOLAR STUDY - JUNE 21 @ 2PM
0 80
GRAPHIC SCALE
40
1 04/13/22 PDP
VINYL WINDOW
SELF ADHERED FLEXIBLE FLASHING
MARRIED 8" UP JAMB
3 1/2"FIBER CEMENT TRIM SYSTEM
FIBER CEMENT PANEL SIDING
WEATHER RESISTIVE BARRIER
X
VINYL WINDOW
SELF ADHERED FLEXIBLE FLASHING
MARRIED 8" UP JAMB
3 1/2"SEALANT
FIBER CEMENT LAP SIDING
WEATHER RESISTIVE BARRIER
X
FIBER CEMENT TRIM SYSTEM
3 1/2"FIBER CEMENT LAP SIDING
WEATHER RESISTIVE BARRIER
SELF ADHERED FLEXIBLE FLASHING
SEALANT
FIBER CEMENT TRIM SYSTEM
SEALANT
VINYL WINDOW
X
SEALANT
3 1/2"FIBER CEMENT PANEL SIDING
WEATHER RESISTIVE BARRIER
SELF ADHERED FLEXIBLE FLASHING
SEALANT
FIBER CEMENT TRIM SYSTEM
SEALANT
VINYL WINDOW
X
SEALANT 1/4"5 1/2"1/4"1/4"FIBER CEMENT LAP SIDING
WEATHER RESISTIVE BARRIER
FIBER CEMENT TRIM SYSTEM
SELF ADHERED FLEXIBLE FLASHING
FLASHING
SEALANT
WEATHER RESISTIVE BARRIER
VINYL WINDOW
SEALANT
X
5 1/2"1/4"FIBER CEMENT LAP SIDING
WEATHER RESISTIVE BARRIER
FIBER CEMENT TRIM SYSTEM
SELF ADHERED FLEXIBLE FLASHING
FLASHING
SEALANT
WEATHER RESISTIVE BARRIER
VINYL WINDOW
SEALANT
X
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY:REVIEWED BY:12-04-2022 14:34:11A002
TYPICAL DETAILSIMPALA RENOVATIONS21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COMD CR
3" = 1'-0"4 WINDOW SILL @ FIBER CEMENT PANEL
3" = 1'-0"1 WINDOW SILL @ FIBER CEMENT LAP SIDING
3" = 1'-0"2 WINDOW JAMB @ FIBER CEMENT LAP SIDING
3" = 1'-0"5 WINDOW JAMB @ FIBER CEMENT PANEL
3" = 1'-0"3 WINDOW HEAD @ FIBER CEMENT LAP SIDING
3" = 1'-0"6 WINDOW HEAD @ FIBER CEMENT PANEL
04/13/22 PDP
A202A
2
1
C
A202A 4
3
22'-1 1/2" 7'-10 1/2"
2
A202A1
CLUBHOUSE
4
A
30'-0"81'-1"
7'-0 1/2"60'-0"14'-0 1/2"
OFFICE
OFFICE
STORAGE
B
A201A1
A201A
2
A201A
3
A201A 4 TEEN/COMPUTER
AREA
KITCHEN
FLEXIBLE AREA
8'-8"13'-4"
A201A7
A201A
5
A201A
6
A201A 8
A202A
5
A202A
6
A202A7
A202A 8
A202A
2
1
C
A202A 4
32
A202A1
4
A
B
A201A1
A201A
2
A201A
3
A201A 4
81'-1"
7'-0 1/2"60'-0"14'-0 1/2"22'-1 1/2" 7'-10 1/2"30'-0"3:123:123:124:12 4:12 9:12 9:12 3:123:123575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY:REVIEWED BY:4/12/2022 8:15:55 PMA101A
BLDG A & TRASH
ENCLOSURE -FLOOR
PLANS IMPALA RENOVATIONS21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COMD CR
1" = 10'-0"1 LEVEL 1 PLAN
0 20
GRAPHIC SCALE
10
BLDG A
KEY PLAN -306 IMPALA
04/13/22 PDP
1" = 10'-0"3 TRASH ENCLOSURE PLAN
1" = 10'-0"2 ROOF PLAN
100' -0"
LEVEL 1
112' -0"
TOP LEVEL 1
C
96' -0"
TO FOOTING
A
119' -3 1/2"
TO ROOF
B
19'-3 1/2"4'-0" 12'-0" 7'-3 1/2"
100' -0"
LEVEL 1
112' -0"
TOP LEVEL 1
1
96' -0"
TO FOOTING
32 4
119' -3 1/2"
TO ROOF
7'-3 1/2"12'-0"4'-0"19'-3 1/2"100' -0"
LEVEL 1
112' -0"
TOP LEVEL 1
1
96' -0"
TO FOOTING
3 24
119' -3 1/2"
TO ROOF
4'-0" 12'-0" 7'-3 1/2"19'-3 1/2"100' -0"
LEVEL 1
112' -0"
TOP LEVEL 1
C
96' -0"
TO FOOTING
A
119' -3 1/2"
TO ROOF
B
4'-0" 12'-0" 7'-3 1/2"19'-3 1/2"TREX
GATE WITH
PAINTED
CORRUGATED
METAL INFILLTREXTREXTREX
ELEVATION LEGEND
SMOOTH HORIZONTAL FIBER CEMENT LAP SIDING
SMOOTH FIBER CEMENT BOARD & BATTEN SIDING
ASPHALT SHINGLE ROOF
STONE VENEER
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:4/12/2022 8:01:02 PMA201A
BLDG A & TRASH
ENCLOSURE -
ELEVATIONSIMPALA RENOVATIONS21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COMD CR
0 20
GRAPHIC SCALE
10
1" = 10'-0"1 EAST ELEVATION
1" = 10'-0"2 NORTH ELEVATION
1" = 10'-0"3 SOUTH ELEVATION
1" = 10'-0"4 WEST ELEVATION
BLDG A
KEY PLAN -306 IMPALA
1" = 10'-0"5 TRASH ENCLOSURE - ENTRY ELEVATION
1" = 10'-0"6 TRASH ENCLOSURE - ENTRY ELEVATION
1" = 10'-0"7 TRASH ENCLOSURE - SIDE ELEVATION
1" = 10'-0"8 TRASH ENCLOSURE - SIDE ELEVATION
04/13/22 PDP
100' -0"
LEVEL 1
112' -0"
TOP LEVEL 1
96' -0"
TO FOOTING
119' -3 1/2"
TO ROOF
100' -0"
LEVEL 1
112' -0"
TOP LEVEL 1
96' -0"
TO FOOTING
119' -3 1/2"
TO ROOF
100' -0"
LEVEL 1
112' -0"
TOP LEVEL 1
96' -0"
TO FOOTING
119' -3 1/2"
TO ROOF
100' -0"
LEVEL 1
112' -0"
TOP LEVEL 1
96' -0"
TO FOOTING
119' -3 1/2"
TO ROOF
TREXTREXTREXTREX
ELEVATION LEGEND
SMOOTH HORIZONTAL FIBER CEMENT LAP SIDING
SMOOTH FIBER CEMENT BOARD & BATTEN SIDING
ASPHALT SHINGLE ROOF
STONE VENEER
EXTERIOR COLORS
ROOFING -CHARCOAL
COLOR 01 -SHERWIN WILLIAMS "GAUNTLET GRAY"
COLOR 02 -SHERWIN WILLIAMS "FIRED BRICK"
COLOR 03 -STAINED WOOD
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:4/12/2022 8:01:20 PMA202A
BLDG A & TRASH
ENCLOSURE-COLORED
ELEVATIONSIMPALA RENOVATIONS21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COMD CR
1" = 10'-0"1 EAST ELEVATION
1" = 10'-0"2 NORTH ELEVATION
1" = 10'-0"3 SOUTH ELEVATION
1" = 10'-0"4 WEST ELEVATION
0 20
GRAPHIC SCALE
10
BLDG A
KEY PLAN -306 IMPALA
1" = 10'-0"5 TRASH ENCLOSURE - ENTRY ELEVATION
1" = 10'-0"6 TRASH ENCLOSURE - ENTRY ELEVATION
1" = 10'-0"7 TRASH ENCLOSURE - SIDE ELEVATION
1" = 10'-0"8 TRASH ENCLOSURE - SIDE ELEVATION
04/13/22 PDP
GATE WITH PAINTED
CORRUGATED METAL INFILL
STEEL DROP ROD AND
SLEEVE
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:4/12/2022 8:02:05 PMA301A
BLDG A -3D VIEWSIMPALA RENOVATIONS21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COMD CR
1 SW CORNER
2 NE CORNER
04/13/22 PDP
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:4/12/2022 8:02:39 PMA302A
BLDG A -3D VIEWSIMPALA RENOVATIONS21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COMD CR
1 EAST FACADE
2 VIEW OF ENTRY
04/13/22 PDP
A202B
1123456 7 8 9 10 11
A
B
C
D
E
F
G
H
I
A202B
2
A202B3
A202B 4
PATIO PATIO PATIO
PATIO
PATIO
PATIOPATIO
PATIO
743 SF
UNIT TYPE 1A-H1
101
924 SF
UNIT TYPE 2B-H1
102
924 SF
UNIT TYPE 2B-H1
103
743 SF
UNIT TYPE 1A-H1
104
1,147 SF
UNIT TYPE 3A-H1
105
924 SF
UNIT TYPE 2B-H1
106
924 SF
UNIT TYPE 2B-H1
107
1,147 SF
UNIT TYPE 3A-H1
108
133 SF
BIKE STORAGE
109
133 SF
BIKE STORAGE
110
70'-2 7/8"4'-11 7/8"11 3/4"4'-9 3/4"24'-1"24'-1"4'-9 3/4"11 3/4"5'-6"150'-1 1/2"
14'-8 3/4" 13'-9 1/4" 11'-1 1/2" 10'-1 3/4" 25'-3 1/2"25'-3 1/2" 10'-1 3/4" 11'-1 1/2" 13'-9 1/4" 14'-8 3/4"
A201B
2
A201B
1
A201B3
A201B 4
39 SF
RISER
111
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY:REVIEWED BY:12-04-2022 15:53:33A101B
BLDG B - FLOOR
PLAN IMPALA RENOVATIONS21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COMD CR
1" = 10'-0"1 LEVEL 1 PLAN
0 20
GRAPHIC SCALE
10
BLDG B
KEY PLAN -306 IMPALA
04/13/22 PDP
A202B
1123456 7 8 9 10 11
A
B
C
D
E
F
G
H
I
A202B
2
A202B3
A202B 4
890 SF
UNIT TYPE 2A-H1
201
924 SF
UNIT TYPE 2B-H1
202
924 SF
UNIT TYPE 2B-H1
203
890 SF
UNIT TYPE 2A-H1
204
1,147 SF
UNIT TYPE 3A-H1
205
924 SF
UNIT TYPE 2B-H1
206
924 SF
UNIT TYPE 2B-H1
207
1,147 SF
UNIT TYPE 3A-H1
2084:126:12 6:12
5:125:126:12 6:12
4:125:125:12BALCONY BALCONY 70'-2 7/8"4'-11 7/8"11 3/4"4'-9 3/4"24'-1"24'-1"4'-9 3/4"11 3/4"5'-6"150'-1 1/2"
14'-8 3/4" 13'-9 1/4" 11'-1 1/2" 10'-1 3/4" 25'-3 1/2"25'-3 1/2" 10'-1 3/4" 11'-1 1/2" 13'-9 1/4" 14'-8 3/4"
A201B
2
A201B
1
A201B3
A201B 4
4:12
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:12-04-2022 15:53:36A102B
BLDG B -FLOOR PLANIMPALA RENOVATIONS21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COMD CR
1" = 10'-0"1 LEVEL 2 PLAN
0 20
GRAPHIC SCALE
10
BLDG B
KEY PLAN -306 IMPALA
04/13/22 PDP
A202B
1123456 7 8 9 10 11
A
B
C
D
E
F
G
H
I
A202B
2
A202B3
A202B 4
6:12 6:12
6:12
6:12
6:12 6:12 6:126:126:126:129:12 9:12 9:12 9:12
9:12 9:12 9:12 9:12 6:126:126:12
6:126:12
6:12 6:12
6:126:12
4:126:12
4:126:12 70'-2 7/8"4'-11 7/8"11 3/4"4'-9 3/4"24'-1"24'-1"4'-9 3/4"11 3/4"5'-6"150'-1 1/2"
14'-8 3/4" 13'-9 1/4" 11'-1 1/2" 10'-1 3/4" 25'-3 1/2"25'-3 1/2" 10'-1 3/4" 11'-1 1/2" 13'-9 1/4" 14'-8 3/4"
A201B
2
A201B
1
A201B3
A201B 4
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:12-04-2022 15:53:38A103B
BLDG B -ROOF PLANIMPALA RENOVATIONS21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COMD CR
1" = 10'-0"1 ROOF
0 20
GRAPHIC SCALE
10
BLDG B
KEY PLAN -306 IMPALA
04/13/22 PDP
ELEVATION LEGEND
SMOOTH HORIZONTAL FIBER CEMENT LAP SIDING
SMOOTH FIBER CEMENT BOARD & BATTEN SIDING
ASPHALT SHINGLE ROOF
100' -0"
LEVEL 1
110' -1 3/4"
LEVEL 2
109' -0"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
ROOF
96' -0"
TO FOOTING
1234567891011
135' -6"
TO ROOF
4'-0" 9'-0"1'-1 3/4"9'-1 1/8"1'-0 5/8"20'-3 1/2"35'-6"100' -0"
LEVEL 1
110' -1 3/4"
LEVEL 2
109' -0"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
ROOF
96' -0"
TO FOOTING
1 2 3 4 5 6 7 8 9 10 11
135' -6"
TO ROOF
1'-0 5/8"9'-1 1/8"1'-1 3/4"9'-0"4'-0"20'-3 1/2"35'-6"100' -0"
LEVEL 1
110' -1 3/4"
LEVEL 2
109' -0"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
ROOF
96' -0"
TO FOOTING
ABCDEFGHI
135' -6"
TO ROOF
1'-0 5/8"9'-1 1/8"1'-1 3/4"9'-0"4'-0"20'-3 1/2"35'-6"100' -0"
LEVEL 1
110' -1 3/4"
LEVEL 2
109' -0"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
ROOF
96' -0"
TO FOOTING
A B C D E F G H I
135' -6"
TO ROOF
1'-0 5/8"9'-1 1/8"1'-1 3/4"9'-0"4'-0"20'-3 1/2"35'-6"3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:12-04-2022 15:54:06A201B
BLDG B -ELEVATIONSIMPALA RENOVATIONS21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COMD CR
1" = 10'-0"1 EAST ELEVATION (OPEN SPACE)
1" = 10'-0"2 WEST ELEVATION (IMPALA DRIVE)
1" = 10'-0"3 SOUTH ELEVATION
1" = 10'-0"4 NORTH ELEVATION
0 20
GRAPHIC SCALE
10
BLDG B
KEY PLAN -306 IMPALA
04/13/22 PDP
100' -0"
LEVEL 1
110' -1 3/4"
LEVEL 2
109' -0"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
ROOF
96' -0"
TO FOOTING
135' -6"
TO ROOF
100' -0"
LEVEL 1
110' -1 3/4"
LEVEL 2
109' -0"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
ROOF
96' -0"
TO FOOTING
135' -6"
TO ROOF
100' -0"
LEVEL 1
110' -1 3/4"
LEVEL 2
109' -0"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
ROOF
96' -0"
TO FOOTING
135' -6"
TO ROOF
ELEVATION LEGEND
SMOOTH HORIZONTAL FIBER CEMENT LAP SIDING
SMOOTH FIBER CEMENT BOARD & BATTEN SIDING
ASPHALT SHINGLE ROOF
EXTERIOR COLORS
ROOFING -CHARCOAL
COLOR 01 -SHERWIN WILLIAMS "GAUNTLET GRAY"
COLOR 02 -SHERWIN WILLIAMS "REQUISITE GRAY"
COLOR 03 -SHERWIN WILLIAMS "AESTHETIC WHITE"
COLOR 04 -SHERWIN WILLIAMS "PRIVILEGE GREEN"
100' -0"
LEVEL 1
110' -1 3/4"
LEVEL 2
109' -0"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
ROOF
96' -0"
TO FOOTING
135' -6"
TO ROOF
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:12-04-2022 15:54:47A202B
BLDG B -COLORED
ELEVATIONSIMPALA RENOVATIONS21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COMD CR
1" = 10'-0"1 EAST ELEVATION (OPEN SPACE)
1" = 10'-0"2 WEST ELEVATION (IMPALA DRIVE)
1" = 10'-0"3 SOUTH ELEVATION
1" = 10'-0"4 NORTH ELEVATION
0 20
GRAPHIC SCALE
10
BLDG B
KEY PLAN -306 IMPALA
04/13/22 PDP
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:12-04-2022 15:57:04A301B
BLDG B -3D VIEWSIMPALA RENOVATIONS21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COMD CR
1 EAST FACADE (OPEN SPACE)
2 WEST FACADE (IMPALA)
04/13/22 PDP
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:12-04-2022 16:00:00A302B
BLDG B -3D VIEWSIMPALA RENOVATIONS21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COMD CR
1 SE Corner
2 NE Corner
04/13/22 PDP
UP
A203C
2
1
5 1/2"1/2"
2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
171'-0"
14'-8 3/4" 24'-7 3/4" 15'-0 1/4" 24'-6 1/2" 15'-0 1/4" 22'-7 3/4" 15'-0 1/4" 24'-7 3/4" 14'-8 3/4"70'-9"5'-6"29'-10 1/2"8'-5 1/2"10'-0"11'-5"5'-6"A203C
1
743 SF
1-BED
101
BIKE STORAGE
111
656 SF
1-BED
102
656 SF
1-BED
103
656 SF
1-BED
104
743 SF
1-BED
105
PATIOPATIOPATIOPATIOPATIO
PATIO PATIO PATIO PATIO PATIO
1,147 SF
3-BED
106
765 SF
1-BED
107
765 SF
1-BED
108
765 SF
1-BED
109
1,147 SF
3-BED
110
BIKE STORAGE
115
RESIDENT STORAGE
112
BIKE STORAGE
113 RESIDENT STORAGE
114
A201C
2
A201C
1
A203C
1
A203C
2
A202C2
A202C 1
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY:REVIEWED BY:12-04-2022 13:09:49A101C
BLDG C -FLOOR PLANIMPALA RENOVATIONS21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COMD CR
1" = 10'-0"1 LEVEL 1 PLAN
0 20
GRAPHIC SCALE
10
BLDG C
KEY PLAN -306 IMPALA
04/13/22 PDP
UP
A203C
2
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
A203C
1
890 SF
2-BED
201
664 SF
1-BED
202
664 SF
1-BED
203
664 SF
1-BED
204
890 SF
2-BED
205
1,147 SF
3-BED
206
765 SF
1-BED
207
765 SF
1-BED
208
765 SF
1-BED
209
1,147 SF
3-BED
210
178 SF
RESIDENT
STORAGE
211
178 SF
RESIDENT
STORAGE
212
178 SF
RESIDENT
STORAGE
213
157 SF
STORAGE
214
BALCONY BALCONY4:126:12 6:12
4:126:126:12
4:124:126:126:12
4:126:12 6:12
4:124:12171'-0"
14'-8 3/4" 24'-7 3/4" 15'-0 1/4" 24'-6 1/2" 15'-0 1/4" 22'-7 3/4" 15'-0 1/4" 24'-7 3/4" 14'-8 3/4"70'-9"5'-6"29'-10 1/2"8'-5 1/2"10'-0"11'-5"5'-6"A201C
2
A201C
1
A203C
2
A203C
1
A202C2
A202C 1
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:12-04-2022 13:09:52A102C
BLDG C -FLOOR PLANIMPALA RENOVATIONS21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COMD CR
1" = 10'-0"1 LEVEL 2 PLAN
0 20
GRAPHIC SCALE
10
BLDG C
KEY PLAN -306 IMPALA
04/13/22 PDP
A203C
2
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
A203C
1
890 SF
2-BED
301
664 SF
1-BED
302
664 SF
1-BED
303
664 SF
1-BED
304
765 SF
1-BED
305
765 SF
1-BED
307
1,147 SF
3-BED
308
178 SF
RESIDENT
STORAGE
309
178 SF
RESIDENT
STORAGE
310
178 SF
RESIDENT
STORAGE
311
96 SF
STORAGE
313
96 SF
STORAGE
312
BALCONY
4:124:12765 SF
1-BED
314
171'-0"
14'-8 3/4" 24'-7 3/4" 15'-0 1/4" 24'-6 1/2" 15'-0 1/4" 22'-7 3/4" 15'-0 1/4" 24'-7 3/4" 14'-8 3/4"70'-9"5'-6"29'-10 1/2"8'-5 1/2"10'-0"11'-5"5'-6"A201C
2
A201C
1
A203C
1
A203C
2
A202C2
A202C 1
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:12-04-2022 13:09:55A103C
BLDG C -FLOOR PLANIMPALA RENOVATIONS21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COMD CR
1" = 10'-0"1 LEVEL 3 PLAN
0 20
GRAPHIC SCALE
10
BLDG C
KEY PLAN -306 IMPALA
04/13/22 PDP
A203C
2
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
A203C
16:126:126:12
6:126:12 6:126:12
6:12
6:12 6:12
6:12 6:12
4:126:12 6:12
6:12 6:12 6:12 6:126:126:12 6:126:126:12 6:12
171'-0"
14'-8 3/4" 24'-7 3/4" 15'-0 1/4" 24'-6 1/2" 15'-0 1/4" 22'-7 3/4" 15'-0 1/4" 24'-7 3/4" 14'-8 3/4"70'-9"5'-6"29'-10 1/2"8'-5 1/2"10'-0"11'-5"5'-6"A201C
2
A201C
1
A203C
1
A203C
2
A202C2
A202C 1
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:12-04-2022 13:09:58A104C
BLDG C -ROOF PLANIMPALA RENOVATIONS21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COMD CR
1" = 10'-0"1 ROOF
0 20
GRAPHIC SCALE
10
BLDG C
KEY PLAN -306 IMPALA
04/13/22 PDP
100' -0"
LEVEL 1
110' -1 3/4"
LEVEL 2
109' -1 1/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
LEVEL 3
12345678910
129' -4 5/8"
TOP LEVEL 3
130' -5 1/4"
ROOF
146' -2"
TOP LEVEL 4
46'-2"30'-5 1/4"9'-1 1/8"1'-0 5/8"9'-1 1/8"1'-0 5/8"9'-1 1/8"1'-0 5/8"100' -0"
LEVEL 1
110' -1 3/4"
LEVEL 2
109' -1 1/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
LEVEL 3
1 2 3 4 5 6 7 8 9 10
129' -4 5/8"
TOP LEVEL 3
130' -5 1/4"
ROOF
146' -2"
TOP LEVEL 4
46'-2"30'-5 1/4"1'-0 5/8"9'-1 1/8"1'-0 5/8"9'-1 1/8"1'-0 5/8"9'-1 1/8"ELEVATION LEGEND
SMOOTH HORIZONTAL FIBER CEMENT LAP SIDING
SMOOTH FIBER CEMENT BOARD & BATTEN SIDING
ASPHALT SHINGLE ROOF
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:12-04-2022 13:10:08A201C
BLDG C -ELEVATIONSIMPALA RENOVATIONS21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COMD CR
1" = 10'-0"2 EAST ELEVATION
1" = 10'-0"1 WEST ELEVATION
0 20
GRAPHIC SCALE
10
BLDG C
KEY PLAN -306 IMPALA
04/13/22 PDP
100' -0"
LEVEL 1
110' -1 3/4"
LEVEL 2
109' -1 1/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
LEVEL 3
A B C D E F G
129' -4 5/8"
TOP LEVEL 3
130' -5 1/4"
ROOF
146' -2"
TOP LEVEL 4
1'-0 5/8"9'-1 1/8"1'-0 5/8"9'-1 1/8"1'-0 5/8"9'-1 1/8"30'-5 1/4"46'-2"100' -0"
LEVEL 1
110' -1 3/4"
LEVEL 2
109' -1 1/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
LEVEL 3
ABCDEFG
129' -4 5/8"
TOP LEVEL 3
130' -5 1/4"
ROOF
146' -2"
TOP LEVEL 4
1'-0 5/8"9'-1 1/8"1'-0 5/8"9'-1 1/8"1'-0 5/8"9'-1 1/8"30'-5 1/4"46'-2"ELEVATION LEGEND
SMOOTH HORIZONTAL FIBER CEMENT LAP SIDING
SMOOTH FIBER CEMENT BOARD & BATTEN SIDING
ASPHALT SHINGLE ROOF
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:12-04-2022 13:10:20A202C
BLDG C -ELEVATIONSIMPALA RENOVATIONS21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COMD CR
1" = 10'-0"1 NORTH ELEVATION
1" = 10'-0"2 SOUTH ELEVATION
BLDG C
KEY PLAN -306 IMPALA020
GRAPHIC SCALE
10
04/13/22 PDP
100' -0"
LEVEL 1
110' -1 3/4"
LEVEL 2
109' -1 1/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
LEVEL 3
129' -4 5/8"
TOP LEVEL 3
130' -5 1/4"
ROOF
146' -2"
TOP LEVEL 4
100' -0"
LEVEL 1
110' -1 3/4"
LEVEL 2
109' -1 1/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
LEVEL 3
129' -4 5/8"
TOP LEVEL 3
130' -5 1/4"
ROOF
146' -2"
TOP LEVEL 4
ELEVATION LEGEND
SMOOTH HORIZONTAL FIBER CEMENT LAP SIDING
SMOOTH FIBER CEMENT BOARD & BATTEN SIDING
ASPHALT SHINGLE ROOF
EXTERIOR COLORS
ROOFING -CHARCOAL
COLOR 01 -SHERWIN WILLIAMS "GAUNTLET GRAY"
COLOR 02 -SHERWIN WILLIAMS "REQUISITE GRAY"
COLOR 03 -SHERWIN WILLIAMS "AESTHETIC WHITE"
COLOR 04 -SHERWIN WILLIAMS "MOODY BLUE"
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY:REVIEWED BY:4/12/2022 8:52:12 PMA203C
BLDG C -COLORED
ELEVATIONSIMPALA RENOVATIONS21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COMD CR
1" = 10'-0"1 WEST ELEVATION
1" = 10'-0"2 EAST ELEVATION
0 20
GRAPHIC SCALE
10
BLDG C
KEY PLAN -306 IMPALA
04/13/22 PDP
100' -0"
LEVEL 1
110' -1 3/4"
LEVEL 2
109' -1 1/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
LEVEL 3
129' -4 5/8"
TOP LEVEL 3
130' -5 1/4"
ROOF
146' -2"
TOP LEVEL 4
100' -0"
LEVEL 1
110' -1 3/4"
LEVEL 2
109' -1 1/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
LEVEL 3
129' -4 5/8"
TOP LEVEL 3
130' -5 1/4"
ROOF
146' -2"
TOP LEVEL 4
ELEVATION LEGEND
SMOOTH HORIZONTAL FIBER CEMENT LAP SIDING
SMOOTH FIBER CEMENT BOARD & BATTEN SIDING
ASPHALT SHINGLE ROOF
EXTERIOR COLORS
ROOFING -CHARCOAL
COLOR 01 -SHERWIN WILLIAMS "GAUNTLET GRAY"
COLOR 02 -SHERWIN WILLIAMS "REQUISITE GRAY"
COLOR 03 -SHERWIN WILLIAMS "AESTHETIC WHITE"
COLOR 04 -SHERWIN WILLIAMS "MOODY BLUE"
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:4/12/2022 8:52:34 PMA204C
BLDG C -COLORED
ELEVATIONSIMPALA RENOVATIONS21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COMD CR
1" = 10'-0"1 NORTH ELEVATION
1" = 10'-0"2 SOUTH ELEVATION
0 20
GRAPHIC SCALE
10
BLDG C
KEY PLAN -306 IMPALA
04/13/22 PDP
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:4/12/2022 8:47:08 PMA301C
BLDG C -3D VIEWSIMPALA RENOVATIONS21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COMD CR
1 WEST FACADE (OPEN SPACE)
2 EAST FACADE (IMPALA CIRCLE)
04/13/22 PDP
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:4/12/2022 8:48:22 PMA302C
BLDG C -3D VIEWSIMPALA RENOVATIONS21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COMD CR
1 SW CORNER
2 NE CORNER
04/13/22 PDP
WH
A202D
1
B
C
D
E39'-0"2'-0"16'-2 3/4"18'-9 1/4"2'-0"5'-0"123457
A202D
2
F
A
6
A202D3
94'-8 1/2"
21'-3 1/2"14'-9 1/4"14'-9 1/4"14'-9 1/4"14'-6 1/2"14'-6 3/4"
761 SF
UNIT TYPE 3A
110
524 SF
UNIT TYPE 2A
111
524 SF
UNIT TYPE 2A
112
524 SF
UNIT TYPE 2A
113
979 SF
UNIT TYPE 3A-H1
114
PROVIDE CONVENIENCE
OUTLETS AT EACH BACK PATIO
FOR CHARGING ELEC BIKES
A202D 4
A201D
1
A201D
2
A201D3
A201D 4
23 33 00
12 93 13
A202D
1
B
C
D
E
123457
A202D
2
F
A
6
A202D3
761 SF
UNIT TYPE 3A
116
494 SF
UNIT TYPE 2A
117
498 SF
UNIT TYPE 2A
118
498 SF
UNIT TYPE 2A
119
484 SF
UNIT TYPE 3A-H1
120
6:124:124:124:126:12 6:12
6:12
39'-0"2'-0"16'-2 3/4"18'-9 1/4"2'-0"5'-0"94'-8 1/2"
21'-3 1/2"14'-9 1/4"14'-9 1/4"14'-9 1/4"14'-6 1/2"14'-6 3/4"
A202D 4 6:126:126:126:124:124:126:12
A201D
1
A201D
2
A201D3
A201D 4 4:124:124:123575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:12-04-2022 14:34:12A101D
BLDG D -FLOOR
PLANS (BLDG E
SIMILAR)IMPALA RENOVATIONS21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COMD CR
1" = 10'-0"1 LEVEL 1 PLAN
1" = 10'-0"2 LEVEL 2 PLAN
0 20
GRAPHIC SCALE
10
KEYNOTES
Key Value Keynote Text
12 93 13 WALL MOUNTED BICYCLE RACKS
23 33 00 AIR DUCT ACCESSORIES
BLDG E BLDG D
KEY PLAN -306 IMPALA
04/13/22 PDP
A202D
1
B
C
D
E
123457
A202D
2
F
A
6
A202D3
39'-0"2'-0"16'-2 3/4"18'-9 1/4"2'-0"5'-0"94'-8 1/2"
21'-3 1/2"14'-9 1/4"14'-9 1/4"14'-9 1/4"14'-6 1/2"14'-6 3/4"
A202D 4
6:126:126:12
6:126:12
6:12 6:12
6:12
6:12 6:126:126:126:12 6:12
6:12 6:12
4:124:126:126:126:126:12
A201D
1
A201D
2
A201D3
A201D 4
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:12-04-2022 14:34:13A102D
BUILDING D -ROOF
PLAN (BLDG E
SIMILAR)IMPALA RENOVATIONS21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COMD CR
1" = 10'-0"1 ROOF PLAN
0 20
GRAPHIC SCALE
10
BLDG E BLDG D
KEY PLAN -306 IMPALA
04/13/22 PDP
ELEVATION LEGEND
SMOOTH HORIZONTAL FIBER CEMENT LAP SIDING
SMOOTH FIBER CEMENT BOARD & BATTEN SIDING
ASPHALT SHINGLE ROOF
100' -0"
LEVEL 1
110' -1 3/4"
LEVEL 2
109' -1 1/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
LEVEL 3
1 2 3 4 5 76
97' -0"
TO FOOTING
129' -11"
TO ROOF
3'-0" 9'-1 1/8"1'-0 5/8"9'-1 1/8"1'-0 5/8"9'-7 1/2"29'-11"20'-3 1/2"100' -0"
LEVEL 1
110' -1 3/4"
LEVEL 2
109' -1 1/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
LEVEL 3
1234576
97' -0"
TO FOOTING
129' -11"
TO ROOF
1'-0 5/8"9'-1 1/8"1'-0 5/8"9'-1 1/8"3'-0"29'-11"20'-3 1/2"100' -0"
LEVEL 1
110' -1 3/4"
LEVEL 2
109' -1 1/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
LEVEL 3
BCDEF A
97' -0"
TO FOOTING
129' -11"
TO ROOF
3'-0"9'-1 1/8"1'-0 5/8"9'-1 1/8"1'-0 5/8"29'-11"20'-3 1/2"100' -0"
LEVEL 1
110' -1 3/4"
LEVEL 2
109' -1 1/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
LEVEL 3
B C D E FA
97' -0"
TO FOOTING
129' -11"
TO ROOF
3'-0"9'-1 1/8"1'-0 5/8"9'-1 1/8"1'-0 5/8"29'-11"20'-3 1/2"3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:12-04-2022 14:34:20A201D
BUILDING D -
ELEVATIONS(BLDG E
SIMILAR)IMPALA RENOVATIONS21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COMD CR
1" = 10'-0"1 NORTH ELEVATION
1" = 10'-0"2 SOUTH ELEVATION
1" = 10'-0"3 EAST ELEVATION
1" = 10'-0"4 WEST ELEVATION1
0 20
GRAPHIC SCALE
10
KEYNOTES
Key Value Keynote Text
12 93 13 WALL MOUNTED BICYCLE RACKS
23 33 00 AIR DUCT ACCESSORIES
BLDG E BLDG D
KEY PLAN -306 IMPALA
04/13/22 PDP
100' -0"
LEVEL 1
110' -1 3/4"
LEVEL 2
109' -1 1/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
LEVEL 3
97' -0"
TO FOOTING
129' -11"
TO ROOF
100' -0"
LEVEL 1
110' -1 3/4"
LEVEL 2
109' -1 1/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
LEVEL 3
97' -0"
TO FOOTING
129' -11"
TO ROOF
100' -0"
LEVEL 1
110' -1 3/4"
LEVEL 2
109' -1 1/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
LEVEL 3
97' -0"
TO FOOTING
129' -11"
TO ROOF
100' -0"
LEVEL 1
110' -1 3/4"
LEVEL 2
109' -1 1/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
LEVEL 3
97' -0"
TO FOOTING
129' -11"
TO ROOF
ELEVATION LEGEND
SMOOTH HORIZONTAL FIBER CEMENT LAP SIDING
SMOOTH FIBER CEMENT BOARD & BATTEN SIDING
ASPHALT SHINGLE ROOF
EXTERIOR COLORS
ROOFING -CHARCOAL
COLOR 01-SHERWIN WILLIAMS "GAUNTLET GRAY"
COLOR 02-SHERWIN WILLIAMS "REQUISITE GRAY"
COLOR 03-SHERWIN WILLIAMS "AESTHETIC WHITE"
COLOR 04-SHERWIN WILLIAMS "CLAY POT"
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY:REVIEWED BY:4/12/2022 8:58:27 PMA202D
BUILDING D -
COLORED
ELEVATIONSIMPALA RENOVATIONS21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COMD CR
1" = 10'-0"1 NORTH ELEVATION
1" = 10'-0"2 SOUTH ELEVATION
1" = 10'-0"3 EAST ELEVATION
1" = 10'-0"4 WEST ELEVATION
0 20
GRAPHIC SCALE
10
BLDG E BLDG D
KEY PLAN -306 IMPALA
04/13/22 PDP
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:12-04-2022 14:34:57A301D
BLDG D -3D VIEWSIMPALA RENOVATIONS21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COMD CR
1 SOUTH FACADE
2 NORTH FACADE
04/13/22 PDP
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:12-04-2022 14:35:23A302D
BLDG D -3D VIEWSIMPALA RENOVATIONS21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COMD CR
1 NW Corner
2 NE Corner
04/13/22 PDP
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:12-04-2022 14:35:52A303D
BLDG D -3D VIEWSIMPALA RENOVATIONS21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COMD CR
1 SW Corner
2 SE Corner
04/13/22 PDP
1
2
3
4
5
6
G F D C B A
814 SF
UNIT TYPE - FLAT
1D-H1
203
900 SF
UNIT TYPE - FLAT
2A-H1
204 68'-6"70'-9"
5'-6"18'-11 3/4"10'-10 3/4"29'-10 1/2"5'-6"14'-8 3/4"13'-11 1/4"11'-2"13'-11 1/4"14'-8 3/4"3:12
3:12
E
A201F
4
A201F3
A201F
2
A201F 1
143 SF
TENANT
STORAGE
209
1
2
3
4
5
6
G F D C B A
890 SF
UNIT TYPE - FLAT
2A-H1
103
744 SF
UNIT TYPE - FLAT
1A-H1
102
743 SF
UNIT TYPE - FLAT
1A-H1
101
900 SF
UNIT TYPE - FLAT
2A-H1
104
116 SF
RISER ROOM
105
PATIOPATIOPATIOPATIO68'-6"70'-9"
5'-6"18'-11 3/4"10'-10 3/4"29'-10 1/2"5'-6"14'-8 3/4"13'-11 1/4"11'-2"13'-11 1/4"14'-8 3/4"E
A201F
4
A201F3
A201F
2
A201F 1
141 SF
TENANT
STORAGE
208
116 SFBIKE PARKING2103575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY:REVIEWED BY:12-04-2022 14:55:59A101F
BLDG F -FLOOR
PLANS IMPALA RENOVATIONS21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COMD CR
1" = 10'-0"2 LEVEL 2
0 20
GRAPHIC SCALE
10
1" = 10'-0"1 LEVEL 1
04/13/22 PDP
1
2
3
4
5
6
G F D C B A
6:126:123:12
3:12
6:126:126:12
6:12
E
A201F
4
A201F3
A201F
2
A201F 1
6:12 6:126:126:12
4:123:126:12 6:126:126:12
4:12
5'-6"18'-11 3/4"10'-10 3/4"10'-3 1/4"19'-7 1/4"5'-6"
70'-9"14'-8 3/4"13'-11 1/4"11'-2"13'-11 1/4"14'-8 3/4"68'-6"3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:12-04-2022 14:56:00A102F
BLDG F -ROOF PLANIMPALA RENOVATIONS21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COMD CR
1" = 10'-0"1 ROOF
0 20
GRAPHIC SCALE
10
04/13/22 PDP
100' -0"
LEVEL 1
110' -1 3/4"
LEVEL 2
109' -1 1/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
ROOF
G F D C B A
128' -7"
LEVEL 4
97' -0"
TO FOOTING
E
1'-0 5/8"9'-1 1/8"1'-0 5/8"9'-1 1/8"20'-3 1/2"100' -0"
LEVEL 1
110' -1 3/4"
LEVEL 2
109' -1 1/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
ROOF
1 2 3 4 5 6
128' -7"
LEVEL 4
97' -0"
TO FOOTING9'-1 1/8"1'-0 5/8"9'-1 1/8"1'-0 5/8"20'-3 1/2"100' -0"
LEVEL 1
110' -1 3/4"
LEVEL 2
109' -1 1/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
ROOF
GFDCBA
128' -7"
LEVEL 4
97' -0"
TO FOOTING
E
1'-0 5/8"9'-1 1/8"1'-0 5/8"9'-1 1/8"20'-3 1/2"100' -0"
LEVEL 1
110' -1 3/4"
LEVEL 2
109' -1 1/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
ROOF
123456
128' -7"
LEVEL 4
97' -0"
TO FOOTING1'-0 5/8"9'-1 1/8"1'-0 5/8"9'-1 1/8"20'-3 1/2"ELEVATION LEGEND
SMOOTH HORIZONTAL FIBER CEMENT LAP SIDING
SMOOTH FIBER CEMENT BOARD & BATTEN SIDING
ASPHALT SHINGLE ROOF
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:12-04-2022 14:56:11A201F
BLDG F -ELEVATIONSIMPALA RENOVATIONS21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COMD CR
1" = 10'-0"4 EAST ELEVATION B/W
1" = 10'-0"3 NORTH ELEVATION B/W
1" = 10'-0"2 WEST ELEVATION B/W
1" = 10'-0"1 SOUTH ELEVATION B/W
0 20
GRAPHIC SCALE
10
04/13/22 PDP
100' -0"
LEVEL 1
110' -1 3/4"
LEVEL 2
109' -1 1/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
ROOF
128' -7"
LEVEL 4
97' -0"
TO FOOTING
100' -0"
LEVEL 1
110' -1 3/4"
LEVEL 2
109' -1 1/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
ROOF
128' -7"
LEVEL 4
97' -0"
TO FOOTING
100' -0"
LEVEL 1
110' -1 3/4"
LEVEL 2
109' -1 1/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
ROOF
128' -7"
LEVEL 4
97' -0"
TO FOOTING
100' -0"
LEVEL 1
110' -1 3/4"
LEVEL 2
109' -1 1/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
ROOF
128' -7"
LEVEL 4
97' -0"
TO FOOTING
ELEVATION LEGEND
SMOOTH HORIZONTAL FIBER CEMENT LAP SIDING
SMOOTH FIBER CEMENT BOARD & BATTEN SIDING
ASPHALT SHINGLE ROOF
EXTERIOR COLORS
ROOFING -MEDIUM BROWN
COLOR 01-SHERWIN WILLIAMS "LAZY GRAY"
COLOR 02-SHERWIN WILLIAMS "SERIOUS GRAY"
COLOR 03-SHERWIN WILLIAMS "EXTRA WHITE"
COLOR 04-SHERWIN WILLIAMS "COPPER WIRE"
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:12-04-2022 14:56:21A202F
BLDG F -COLORED
ELEVATIONSIMPALA RENOVATIONS21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COMD CR
1" = 10'-0"1 SOUTH ELEVATION
1" = 10'-0"2 NORTH ELEVATION
1" = 10'-0"3 WEST ELEVATION
1" = 10'-0"4 EAST ELEVATION
0 20
GRAPHIC SCALE
10
04/13/22 PDP
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:12-04-2022 14:56:45A301F
BLDG F -3D VIEWSIMPALA RENOVATIONS21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COMD CR
1 WEST FACADE
2 EAST FACADE
04/13/22 PDP
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:12-04-2022 14:57:02A302F
BLDG F -3D VIEWSIMPALA RENOVATIONS21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COMD CR
1 SOUTH FACADE (MULBERRY STREET)
04/13/22 PDP
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:12-04-2022 14:57:28A303F
BLDG F -3D VIEWSIMPALA RENOVATIONS21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COMD CR
1 ENTRY CORNER
2 BACK CORNER
04/13/22 PDP