HomeMy WebLinkAboutBUCKING HORSE PARK - BDR210011 - SUBMITTAL DOCUMENTS - ROUND 4 - SUPPORTING DOCUMENTATION Page 1 of 1 Date: 3/29/22 To: City of Fort Collins - Park Planning and Development From: Connor Wilkinson – Clark & Enersen Mechanical Concerning: Bucking Horse Park Water Service Calculations Per the 2018 International Plumbing Code (IPC): Table E103.3(2) Load Values Assigned to Fixtures: FIXTURE OCCUPANCY TYPE OF CONTROL LOAD VALUES, IN WATER SUPPLY FIXTURE UNITS (WSFU) QUANTITY OF FIXTURES TOTAL WSFU Cold Hot Total Drinking Fountain Public 3/8” Valve 0.25 - 0.25 1 0.25 Lavatory Public Faucet 1.5 1.5 2 2 4 Urinal Public ¾” Flushometer 5.0 - 5.0 1 5 Water Closet Public Flushometer Valve 10 - 10 3 30 Total: 39.25 Table E103.3(3) Table for Estimating Demand: SUPPLY SYSTEMS PREDOMINANTLY FOR FLUSHOMETER VALVES LOAD (WSFU) DEMAND GALLONS PER MINUTE CUBIC FEET PER MINUTE 40 46 6.14928 Per the tables presented in the International Plumbing Code (IPC), the fixtures intended for installation at Bucking Horse Park Restroom total 39.25 water supply fixture units (WSFU). This corresponds to a meter/ service demand of 46 gallons per minute. According to Fort Collins Water Utility Development Review Engineer, Matt Simpson, this corresponds to a 1” water meter and service, which can provide the site with 50 gallons per minute.