Loading...
HomeMy WebLinkAboutINTERSTATE LAND PUD, 1ST FILING (HARLEY DAVIDSON) - FINAL - 34-88C - CORRESPONDENCE - APPLICANT COMMUNICATION (3)• P May 1, 1996 Mitchell Haas Project Planner City of Fort Collins Planning Department P.O. Box 580 Fort Collins, CO 80522 Dear Mitch; urban design, inc. 3555 stanford road, suite 105 fort collins, colorado 80525 (970) 226-4074 FAX (970) 226-4196 Attached are 5 prints of the Interstate Land PUD, First Filing (Harley Davidson) Final, indicating our final revisions as agreed at our meetings of April 1 st and April 8th. In addition to the revisions made in the past: - The site plan has been amended to establish a 30' minimum setback/buffer between the existing top of bank of Boxelder Creek and the closest points on the proposed building and parking areas. Bank stabilization at Boxelder Creek has been limited to the area disturbed by the water line crossing of the creek and the adjacent proposed pedestrian bridge. As per your discussion with Terence Hoaglund, some additional revisions have been made to the final landscape plan. Also - for your files - I have attached the letter we received from ELCO regarding the ditch crossing of their water line. Reductions, rendered plans, and eight sets of prints will be provided by May 13th. We appreciate your assistance in this project. Please call if you need further information. Sincerely, Eldon Ward, President Cityscape Urban Design, Inc. cc: Stan Whitaker, LGT John Cockson, John's Harley Davidson Randy Demario, Heath Construction Bill Taylor, RBD, Inc. Engineering Consultants Lucia Liley, March & Myatt • • East Larimer County Water District April 3, 1996 Stan Whitaker LGT 3555 Stanford Ft. Collins, CO 80525 RE: Boxelder Creek Crossing - Interstate Lands PUD Dear Mr. Whitaker: East Larimer County (ELCO) Water District has facilities available to serve the Interstate Lands PUD. Water service for the first phase of the project requires that a 12" water line be installed across Boxelder Creek in the vicinity of the proposed Harley Davidson dealership. The original plan was to install the 12" water line beneath Boxelder Creek. A copy of the profile of the creek crossing that was originally proposed is attached. If installed as originally planned, the water line would have been approximately 19' below finished grade and within the parking lot for the proposed building. Construction of a water line that deep would have been extremely difficult and disruptive to the surrounding area. Maintenance of a water line within a parking lot at that depth is impossible. It is just too deep. To avoid problems associated with installing and maintaining a large utility line 19' under a parking lot, an aerial crossing of Boxelder Creek was designed. An aerial crossing is the only reasonable solution to extending a water line across Boxelder Creek at the location required to serve the proposed Harley Davidson dealership. Please contact me if you have any additional questions about ELCO's requirements for the Boxelder Creek crossing. Sincere y, W. Webster Jon , P.E. Manager, ELCO Water District Enclosure 232 Soulh Link Lane, P.O. Box 2044 • Fort Collins, Colorado 80522 9 Phone (303) 493-2044 • Fax (303) 493-1801 Q, al Date o.Icn! 1 rnl rn� 1210009 .p00 PVFC.PPP�,;--2 40_00 L�900 . •I _ C906 PV PIPE . _ —45 FITTINGS__ ANSITION WITH •FITTINGS 90.00 t.F. 20" - STEEL CASING PIPE 1 ; �.PROPOS ; GRADE , PROPERTY LINE w �.. 1 UI I I I i �►� I .. I EXISTIN I \ o�' ' GROUN x ! I' of I i I call I oi ! QI wl La 01 1 ' Z 4- C.) JJ :..0.. 0I001 0lo10f01 . o.o o -I o; o ?) I o:oi�lo ca st st ►� I 19 18 17 Engineering Consultants