HomeMy WebLinkAbout2908 S TIMBERLINE RD MULTI-FAMILY DWELLINGS - FDP210028 - SUBMITTAL DOCUMENTS - ROUND 3 - RESPONSE TO STAFF REVIEW COMMENTS 244 North College Ave, #130 I Fort Collins, CO 80524 www.norris-design.com April 8, 2022 City of Fort Collins Mr. Kai Kleer 281 N College Avenue Fort Collins, CO 80524 Re: FDP - 2908 S. Timberline Rd Multi-Family Dwellings Dear Kai, Thank you for providing comments on the 2908 Timberline Rd Multi-Family Dwellings FDP which was received on March 28, 2022. Our team’s comment responses are detailed on the following pages. Please feel free to reach out if you have any questions by phone, 970-541-1841 or by email, sbwelch@norris-design.com. Sincerely, Norris Design Savanah Benedick-Welch Project Manager 244 North College Ave, #130 I Fort Collins, CO 80524 www.norris-design.com Comment Summary: Development Review Coordinator Contact: Todd Sullivan, 970 221 6695, tsullivan@fcgov.com Topic: General Comment Number: 1 Comment Originated: 01/25/2022 I will be your primary point of contact throughout the development review and permitting processes. If you have any questions, need additional meetings with the project reviewers, or need assistance throughout the process, please let me know and I can assist you and your team. To best serve you, please include me in all email correspondence with other reviewers and keep me informed of any phone conversations. Thank you! Comment Noted, thank you! Comment Number: 2 Comment Originated: 01/25/2022 As part of your resubmittal, you will respond to the comments provided in this letter. This letter is provided to you in Microsoft Word format. Please use this document to insert responses to each comment for your submittal, using a different font color. When replying to the comment letter please be detailed in your responses, as all comments should be thoroughly addressed. Provide reference to specific project plans or explanations of why comments have not been addressed, when applicable, avoiding responses like noted or acknowledged. Please follow the Electronic Submittal Requirements and File Naming Standards found at https://www.fcgov.com/developmentreview/files/electronic submittal requirements and file naming standards_v1_8 1 19.pdf?1566857888. Files are to be named PLAN NAME_PROJECT NAME_REVIEW TYPE_ROUND NO. Example: UTILITY PLANS_MY PROJECT_PDP_RD1.pdf Resubmittals are accepted any day of the week, with Wednesday at noon being the cut-off for routing the same week. When you are ready to resubmit your plans, please notify me as much in advance as possible. Comment Noted, thank you! Comment Number: 4 Comment Originated: 01/25/2022 FOR FINAL APPROVAL: All "FOR FINAL APPROVAL / FOR APPROVAL" comments need to be addressed and resolved prior to moving forward with the final documents and recording of this project. I will provide a recording checklist and process information when we are closer to this step. Department: Planning Services Contact: Kai Kleer, 970-416-4284, kkleer@fcgov.com 244 North College Ave, #130 I Fort Collins, CO 80524 www.norris-design.com Topic: General Comment Number: 7 Comment Originated: 01/25/2022 03/18/2022 FOR APPROVAL: Still under discussion. 01/25/2022 FOR APPROVAL: Regarding walkway directness and continuity 3.2.2(C)(7), the south walkway along the private street should connect directly into the Timberline sidewalk system, this off-site pedestrian connection is critical to providing safety, efficiency, and convenience for pedestrians and bicyclists within the area. With the idea that the former CSU property will redevelop sometime in the future let's chat about what might be the best interim or permanent solution for the pedestrian connection. Response: Per discussion with the City, the following note is being added to the plans: A 6-foot wide crusher fine pedestrian walkway shall be constructed to connect the sidewalk system of Timberline Multi-family to the existing sidewalk system of S Timberline Road in the approximate alignment shown. This connection is meant to be temporary in nature and is expected to be modified with the future of the development of 3028 S Timberline Road (parcel # 8729200915). Construction, maintenance, and management of the walkway will be covered under a private agreement which includes Timberline Church, Colorado State University, Tetrad Property Group, or future representative(s) thereof. Department: Engineering Development Review Contact: Sophie Buckingham, , sbuckingham@fcgov.com Topic: General Comment Number: 1 Comment Originated: 01/25/2022 03/22/2022: FOR APPROVAL - UNRESOLVED: City staff is still discussing this. 01/25/2022: FOR APPROVAL: A continuous pedestrian route to Timberline Road will need to be provided. This may involve installing a short stretch of sidewalk to connect two existing sections of sidewalk. Please see my redlines on sheet C300, and coordinate with Engineering, Planning, and Traffic. Response: Per discussion with the City the note above under Planning comments will be added to the plans regarding a temporary crusher fine pedestrian walkway. Comment Number: 7 Comment Originated: 03/22/2022 03/22/2022: FOR APPROVAL: For the sidewalk at the southwest end of the private drive, please construct the 244 North College Ave, #130 I Fort Collins, CO 80524 www.norris-design.com sidewalk all the way to the property line with CSU. See my redlines on Sheet C301. Response: Sidewalk extended to the property line. Comment Number: 8 .Comment Originated: 03/22/2022 03/22/2022: INFORMATION ONLY: Will a temporary construction easement be needed for the saw cut and heavy duty asphalt paving through the church parking lot? Response: a temporary agreement between the developer and the church owner will be established to facilitate construction. Department: Traffic Operation Contact: Spencer Smith, 970-221-6820, smsmith@fcgov.com Topic: General Comment Number: 1 Comment Originated: 01/24/2022 03/18/2022: FOR FINAL APPROVAL I think that there still needs to be at least a ramp to provide a crossing location to the church site, somewhere toward the southwest part of this site. For someone to have to go all the way along the private drive from the south part of the site to the north to get to a suitable crossing is not reasonable. A good location may be somewhere that aligns with an existing church drive aisle. 01/24/2022: There are a few locations along the main drive aisle into the site that may need some pedestrian ramp/crosswalk striping revisions. At the far southwest end of the drive, there is no ramp to take pedestrians north into the church parking lot sidewalk. Along the curve of the drive aisle, near the double existing crosswalks, you show one crosswalk to remain, but it doesn't lead to a ramp on the south side. Also, near the north end of the drive aisle, you have a proposed ramp that angles into the drive aisle intersection, rather than point north to the existing ramp. The existing ramp is not a directional one, which is the City's standard for public pedestrian ramps, but I'd prefer the proposed one to be, at least. Response: It is our recommendation to not provide additional accessible ramps along east side of the private drive to connect to existing sidewalks on the west side of the private drive. Existing sidewalks west of the private drive are not currently accessible and do not have complaint ramps. Constructing complaint ramps on one side of the road would create an unsafe situation by establishing a false sense of protection and a partial complaint route may lead to stranded pedestrians in the roadway. Upgrading the existing walks on the adjacent property to be fully complaint in their entirety is not feasible within the scope of this project. Comment Number: 3 Comment Originated: 03/18/2022 03/18/2022: INFORMATION ONLY It would be helpful for readability of the plans to provide a bit of overlap between sheets where you have matchlines. 244 North College Ave, #130 I Fort Collins, CO 80524 www.norris-design.com Response: Understood Department: Stormwater Engineering – Erosion and Sediment Control Contact: Basil Hamdan, 970-222-1801, bhamdan@fcgov.com Topic: Erosion Control Comment Number: 1 Comment Originated: 03/18/2022 03/18/2022: 01/24/2022: INFORMATION ONLY: Based upon the area of disturbance or this project is part of a larger common development, State permits for stormwater will be required since the site is over an acre and should be pulled before Construction Activities begin. The City Manager’s development review fee schedule under City Code 7.5-2 was updated to include fees for Erosion Control and Stormwater Inspections. As of January 1st, 2021, these fees will be collected on all projects for such inspections. The Erosion Control fees are based on; the number of lots, the total site disturbance, the estimated number of years the project will be active and the Stormwater Inspection Fees are based on the number of LID/WQ Features that are designed for on this project. Based on the proposed site construction associated with this project we are assuming 7 buildings, 12 acres of disturbance, 2 years from demo through build out of construction and an additional 3 years ‘til full vegetative stabilization due to seeding which results in an Erosion Control Inspection Fee estimate of $2431.96. Based on 2 number of bioretention, 1 bioswale, 1 number detention basin, and 2 number of underground treatment systems, the estimate of the Stormwater LID/WQ Inspection fee to be $2025. Please note that as the plans and any subsequent review modifications of the above-mentioned values change the fees may need to be modified. I have provided a copy of the spreadsheet used to arrive at these estimates for you to review. Response: Comment Noted, thank you. Comment Number: 2 Comment Originated: 03/18/2022 03/18/2022: FOR FINAL APPROVAL [UPDATED]: Please note that the plans do not provide any protection along the existing Foothills channel as required and previously requested. The plans will not be approved unless this issue is addressed. Please respond to the redlined comments in the redlined plans as no redlined erosion control plans and responses were returned. 244 North College Ave, #130 I Fort Collins, CO 80524 www.norris-design.com Please indicate how the soil stockpiles will be protected during construction, and do not place any soil stockpiles within detention ponds. Please add sediment forebays at all entry points to rain gardens and bioswale. Please provide erosion protection where there is work in the channel and in the existing parking lot Please address all redlined comments provided on the plans. Please update the erosion control security estimate based on the updated plans after addressing the provided comments. Please note that the $9,000/ acre used in calculating the escrow amount is unreasonably high. Response: Additional protection provided to border of channel. There is no work being performed within the channel. However, seeding and landscaping has been provided to the property line in areas that currently lack vegetation. A permanent irrigation system will be provided for all landscaping. Refer to details on C392 for additional information on the stockpile management areas. Additional forebays have been added to the sidewalk chase outfalls. Additional annotation provided to identify the rain garden fore bays. Existing parking lot slopes towards the site and perimeter protection is not required. Sediment control logs provided. Plan redlines addressed. Security estimate updated. 01/24/2022: FOR FINAL APPROVAL: Please ensure that the Erosion Control Plans provided include a individual sequence sheets in accordance with (FCDCM Ch 2 Section 6.1.3.2) Please ensure that the Erosion Control Plans, Escrows, and Reports include phasing requirements (FCDCM Ch 2 Section 6.1.3, 6.1.4, & 6.1.5) It seems that there will be a demolition phase for this project as well as a construction phase, please provide erosion control plans for the demolition phase as well as the construction phase. This project is adjacent to an existing development as well as wetlands. Extra care should be taken to limit construction access to the church area from the construction site and to protect the downstream channel at all times during construction. Please add notes to that effect on the plans and provide appropriate measures to protect these. 244 North College Ave, #130 I Fort Collins, CO 80524 www.norris-design.com Please address all comments provided on the redlined Erosion and Sediment Control Plans. Response: Redlines addressed. Department: Stormwater Engineering Contact: Wes Lamarque, 970-416-2418, wlamarque@fcgov.com Comment Number: 6 Comment Originated: 01/26/2022 03/22/2022: REPEAT COMMENT: 01/26/2022: FOR FINAL APPROVAL: On sheet C311, the grading looks to be incorrect within the detention basin. Looks like there is a sump within the 4928 contour. Please revise. There are also grading issues throughout the plan set with contours not matching grading. Response: Grading corrected Comment Number: 13 Comment Originated: 01/26/2022 03/22/2022: AMENDED COMMENT: There is also a weir located in the 24-inch Nyoplast structure that needs to be documented with the top of elevation. Also, both Diversion Structures for Filter B are labeled as south on Sheet 813. Please revise. 01/26/2022: FOR FINAL APPROVAL: Please label the elevations for the diversion manholes on the storm sewer profiles for the Stormtech systems. Response: Plans revised Comment Number: 16 Comment Originated: 01/26/2022 03/22/2022: AMENDED COMMENT: I could not find the locations on the Grading Plan. Please show and label these to the detailed grading plans where needed. 01/26/2022: FOR FINAL APPROVAL: Detention pond depth gages are required for ponds greater than 4 feet deep. Please add the City's standard detail to the plans and show and label location on the grading plan. Response: Depth gauge added to sheet C307 Comment Number: 17 Comment Originated: 01/26/2022 03/22/2022: AMENDED COMMENT: Please add the other items not included. 01/26/2022: FOR FINAL APPROVAL: Please add a detention pond summary table to the Drainage Plan. This should include the volume required and volume provided as well as the release rate, the 100-WSEL, WQ Elevation and pond invert. Response: Requested information provided. 244 North College Ave, #130 I Fort Collins, CO 80524 www.norris-design.com Comment Number: 20 Comment Originated: 03/22/2022 03/22/2022: FOR FINAL APPROVAL: For the Bio-swale detail, the City has found that not wrapping the slotted pipe and placing fabric on top of the CDOT Class C filter material has been more successful for the long term. Please revise. Response: Detail revised Comment Number: 21 Comment Originated: 03/22/2022 03/22/2022: FOR FINAL APPROVAL: There are a few locations where riprap is still proposed instead of scour stop. Is there a technical reason for this? If riprap must stay for these couple locations, the City requires the riprap to be buried with 6-inches of topsoil and seeded with a temporary erosion control blanket. Response: Rip-rap detail updated to include 6-inches of topsoil and temporary seeded erosion control blanket. Comment Number: 22 Comment Originated: 03/22/2022 03/22/2022: FOR FINAL APPROVAL: Typically, the Stormtech chamber rows each have a manifold for maintenance access. System B has a few chamber rows without a manifold for maintenance access. Please revise. Response: Stormtech Design updated Comment Number: 23 Comment Originated: 03/23/2022 03/23/2022: FOR FINAL APPROVAL: The run downs where the slopes are around 4:1 should be graded with a v-notch (low point) to ensure smaller flows will stay within the scour protection. Response: Additional detail for v-notch run downs added Department: Water-Wastewater Engineering Contact: Wes Lamarque, 970-416-2418, wlamarque@fcgov.com Topic: General Comment Number: 1 Comment Originated: 01/25/2022 01/25/2022: FOR PLAN APPROVAL: In some utility crossings, the water hydrant, fire and domestic services are below the public sewer main. The City would prefer these be above the sewer main. It appears this can be accomplished with 1 foot of separation and with 4 feet of cover. Please revise where these conditions can be met. Response: Waterline has been adjusted Comment Number: 2 Comment Originated: 01/25/2022 244 North College Ave, #130 I Fort Collins, CO 80524 www.norris-design.com 03/23/2022: UPDATED COMMENT: Please add note to sanitary sewer plans. 01/25/2022: FOR PLAN APPROVAL: Please change the note on the plans to read "insulate any sanitary sewer less than 48-inches" rather than 36-inches. Response: Profile updated and note added to sheets Comment Number: 3 Comment Originated: 01/25/2022 03/23/2022: UPDATED COMMENT: Calculations need to be AWWA for meter sizing. Also, early observations show that the 36-plex will need a 2-inch water service. 01/25/2022: FOR PLAN APPROVAL: Please provide water sizing calculations for the multi-family buildings to justify the 1 1/2 inch domestic service. Response: 36-PLEX service line increased to 2" Comment Number: 4 Comment Originated: 01/25/2022 03/23/2022: FOR YOUR INFORMATION: The City Inspector will require all joints to be restrained as this is City Utilities preferred option. 01/25/2022: FOR PLAN APPROVAL: Please add a note on the water plans that all joints are to be restrained. This is currently preferred over any thrust blocks. Response: Notes added to plans Comment Number: 7 Comment Originated: 01/28/2022 03/23/2022: AMENDED COMMENT: Some plantings are on top of the meter. 01/28/2022: FOR FINAL APPROVAL: The southwestern most water meter needs to have 4 feet clear from any fully mature shrubs and have a clear path to a hard surface. Response: Noted. Plants have been removed to accommodate the needed clearances. Comment Number: 9 Comment Originated: 03/23/2022 03/23/2022: FOR FINAL APPROVAL: Separate irrigation service is required due to recent changes to Fort Collins Utilities Water Supply Requirements (WSR) and Plant Investment Fees (PIF). Please ensure the project submittal includes: - Preliminary Irrigation Plan (PIP) – plan requirements can be found at: www.fcgov.com/WCS. Please contact Irrigation Development Review (irrigation@fcgov.com) with questions regarding the required PIP. - Water budget (annual usage) and peak flow (gallons per minute) for each 244 North College Ave, #130 I Fort Collins, CO 80524 www.norris-design.com irrigation service. Note: this information should be included on the PIP. - Landscape Plan including hydrozone table updated with 2022 values – 3, 8, 14, and 18 gallons/square foot/year for very low, low, medium, and high zones, respectively. - Water Need Form – form is available at: www.fcgov.com/WFF Please contact Utility Fee and Rate Specialists (UtilityFees@fcgov.com or 970-416-4252) with questions regarding the Water Need Form. - Irrigation service(s), including curb stop and meter location, shown on the Utility and Site Plans. Irrigation service location(s) must match information on the PIP. On Oct. 5, 2021, Council adopted changes to Fort Collins Utilities Water Supply Requirements and Plant Investment Fees. In general developments that use more water may pay more and developments that use less water may pay less. These changes were implemented 1/1/2022; more information can be found at: www.fcgov.com/wsr-update Response: A PIP is being provided with this submittal; a separate meter is being provided for landscape. A hydrozone plan and water budget table are included in the landscape set (sheet LP003) and the values in the water budget table have been updated to meet 2022 requirements. Comment Number: 10 Comment Originated: 03/25/2022 03/25/2022: FOR FINAL APPROVAL: In situations where the sanitary sewer main is below a storm sewer 24-inches or larger, the sanitary line is required to be in a casing pipe. Please revise. Response: Steel casing provided at crossing locations Comment Number: 11 Comment Originated: 03/25/2022 03/25/2022: FOR FINAL APPROVAL: In situations where any public water main or hydrant lateral is under a sanitary sewer or other no-potable pipe, Water Utilities Criteria requires all joints of the non-potable utility within 10 feet of the water line be wrapped with butyl adhesive tape or the piping of the non-potable system within 10 feet of the water line be C900/C905 PVC. This would be the recommended option for the private water and fire services under the sanitary sewer as well instead of concrete encasement. Response: Note added to plan sheets Comment Number: 12 Comment Originated: 03/25/2022 03/25/2022: FOR FINAL APPROVAL: The City does not want the watermain lowered in order to reduce water service lowering's. Each service will need to be lowered as required. Please revise. Response: Watermain lowerings removed. Comment Number: 13 Comment Originated: 03/25/2022 244 North College Ave, #130 I Fort Collins, CO 80524 www.norris-design.com 03/25/2022: FOR FINAL APPROVAL: The City requires any water main lowering under a pipe size of 18-inches or larger for the water main be installed in a casing pipe. Please revise lowering on Sheet C703 and the lowering on Sheet C701 at St. 6+50. Response: Waterline adjusted Comment Number: 14 Comment Originated: 03/25/2022 03/25/2022: FOR FINAL APPROVAL: It appears the watermain lowering on Sheet C701 at St. 7+50 can be avoided with a smaller clearance. Please remove this lowering and adjust water main elevation to provide 12 inches of vertical clearance to the storm sewer. Also, the watermain is required to be installed within a casing pipe under the storm. Response: Waterline adjusted Department: Light And Power Contact: Luke Unruh, 970-416-2724, lunruh@fcgov.com Topic: General Comment Number: 5 Comment Originated: 01/25/2022 01/25/2022: FOR BUILDING PERMIT Please provide a C-1 form and one-line diagram for each building. A link to the C-1 form is below: http://www.fcgov.com/utilities/business/builders-and-developers/development- forms-guidelines-regulations Response: Noted for Building Permit, thank you. Comment Number: 7 Comment Originated: 03/22/2022 03/22/2022: L&P IS READY FOR RECORDING Department: Environmental Planning Contact: Kelly Smith, , ksmith@fcgov.com Topic: General Comment Number: 1 Comment Originated: 01/25/2022 01/25/2022: FOR APPROVAL SAME COMMENT 3.23.2022 Please ensure all plant species within the NHBZ are native to Fort Collins. Mugo Pine is not native to Colorado. Response: This has been revised. Comment Number: 2 Comment Originated: 01/25/2022 01/25/2022: FOR APPROVAL 244 North College Ave, #130 I Fort Collins, CO 80524 www.norris-design.com SAME COMMENT 3.23.2022 Language regarding the protection and enhancement of the Natural Habitat Buffer Zone will be included in the Development Agreement for this project. A security will need to be provided prior to the issuance of a Development Construction Permit that accounts for the installation and establishment of the Natural Habitat Buffer Zone. Prior to the FDP approval please provide an estimate of the landscaping costs for the Natural Habitat Buffer Zone, including materials, labor, monitoring for a minimum of three years, weed mitigation and irrigation. We will then use the approved estimate to collect a security (bond or escrow) at 125% of the total amount prior to the issuance of a Development Construction Permit. Response: It is understood that this language will be a part of the DA. An estimate of landscape costs for the NHBZ is being provided with this submittal. Department: Forestry Contact: Molly Roche, 224-616-1992, mroche@fcgov.com Topic: General Comment Number: 18 Comment Originated: 01/25/2022 3/21/2022: FOR FINAL APPROVAL – UPDATED Continued: There are a few remaining tree-utility conflicts that are noted on the Round 2 landscape plan redlines. Response: This conflict has been addressed. 1/25/2022: FOR FINAL APPROVAL Please review Forestry redlines for remaining tree-utility conflicts and other questions regarding unlabeled attributes on the plans. Response: This has been addressed. Department: Technical Services Contact: Jeff County, 970-221-6588, jcounty@fcgov.com Comment Number: 11 Comment Originated: 01/26/2022 03/22/2022: FOR FINAL APPROVAL-UNRESOLVED: Please provide the following information for the Benchmark Statement in the EXACT format shown below. PROJECT DATUM: NAVD88 BENCHMARK # w/ DESCRIPTION ELEVATION: BENCHMARK # w/ DESCRIPTION ELEVATION: 244 North College Ave, #130 I Fort Collins, CO 80524 www.norris-design.com PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) = NAVD88 DATUM - X.XX’. 01/26/2022: FOR FINAL APPROVAL: Please provide the following information for the Benchmark Statement in the EXACT format shown below. PROJECT DATUM: NAVD88 BENCHMARK # w/ DESCRIPTION ELEVATION: BENCHMARK # w/ DESCRIPTION ELEVATION: PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) = NAVD88 DATUM - X.XX’. Response: Comment addressed Comment Number: 12, 14 and 15 Comment Originated: 01/26/2022 03/22/2022: FOR FINAL APPROVAL: There are line over text issues. See redlines. Response: Redlines addressed Comment Number: 17 Comment Originated: 01/26/2022 03/22/2022: FOR FINAL APPROVAL: There is text that needs to be masked. Mask all text in hatched areas. See redlines. Response: Redlines addressed Topic: Plat 244 North College Ave, #130 I Fort Collins, CO 80524 www.norris-design.com Comment Number: 1 Comment Originated: 01/25/2022 03/22/2022: FOR FINAL APPROVAL-UPDATED: Please make changes as marked. If changes are not made or you disagree with comments, please provide written response of why corrections were not made. Please provide any responses on redlined sheets and/or in response letter. If you have any specific questions about the redlines, please contact John Von Nieda at 970-221-6565 or jvonnieda@fcgov.com Response: Redlines addressed Department: Water Conservation Contact: Eric Olson, 970-221-6704, eolson@fcgov.com Topic: General Comment Number: 1 Comment Originated: 03/22/2022 03/22/2022: Irrigation plans are required no later than at the time of building permit. The irrigation plans must comply with the provisions outlined in Section 3.2.1(J) of the Land Use Code. Direct questions concerning irrigation requirements to Eric Olson, at 221-6704 or eolson@fcgov.com Response: A Preliminary Irrigation Plan is provided with this resubmittal per information provided above.