Modification Request Modification Request Modification Request Modification Request –––– RelationshipRelationshipRelationshipRelationship of of of of Dwellings to StreetsDwellings to StreetsDwellings to StreetsDwellings to Streets
March 9, 2022
Land Use CodeLand Use CodeLand Use CodeLand Use Code
3.5.23.5.23.5.23.5.2((((DDDD))))(1)(b) (1)(b) (1)(b) (1)(b) ----Relationship of Dwellings to Streets and ParkingRelationship of Dwellings to Streets and ParkingRelationship of Dwellings to Streets and ParkingRelationship of Dwellings to Streets and Parking
(1) Orientation to a Connecting Walkway. Every front facade with a primary entrance to a
dwelling unit shall face the adjacent street to the extent reasonably feasible. Every front facade with a
primary entrance to a dwelling unit shall face a connecting walkway with no primary entrance more
than two hundred (200) feet from a street sidewalk and the address shall be posted to be visible from
the intersection of the connecting walkway and public right of way. The following exceptions to this
standard are permitted:
(b) A primary entrance may be up to three hundred fifty (350) feet from a street sidewalk if the
primary entrance faces and opens directly onto a connecting walkway that qualifies as a major
walkway spine.
Article 5 Article 5 Article 5 Article 5 –––– Terms Terms Terms Terms and Definitionsand Definitionsand Definitionsand Definitions
Major walkway spine shall mean a tree-lined connecting walkway that is at least five (5) feet wide,
with landscaping along both sides, located in an outdoor space that is at least thirty-five (35) feet in
its smallest dimension, with all parts of such outdoor space directly visible from a public street.
Reason for the RequestReason for the RequestReason for the RequestReason for the Request
The Enclave at Redwood Project Development Plan (PDP) is a residential project that aims at
providing a different type of rental housing to the Fort Collins market. The site plan proposes 40
townhome style buildings all on one lot, enabling them to be owned and maintained by a single
entity. This rental housing model creates a neighborhood with a variety of housing options, both in
the type of residence and style. One way the development aims to ensure that there is no chance
of a monotonous streetscape is by providing alley loaded dwellings that front on to a Major
Walkway Spine (MWS) in lieu of a street, as allowed in LUC Section 3.5.2(D)(1)(b). One of the major
advantages to the public of alley loaded dwellings is that they are designed to hide the garage,
which is generally less aesthetically appealing, away from the public view. The fronts of the units
are no longer dominated by large, unattractive garage doors, and instead present articulated and
human-scaled elements to the public. Traditionally alley loaded townhomes front public streets,
however more and more people are wanting to live in a home that fronts directly onto nature
instead of a vehicle dominated domain.
MINIMAL RISK. PAINLESS PROCESS. BEAUTIFUL SPACES.
o: 970.224.5828 | w: ripleydesigninc.com
RIPLEY DESIGN, INC. | 419 Canyon Avenue, Suite 200 | Fort Collins, CO 80521
The reason for this modification request is that 11 of the 240 dwellings are located along a MWS
that is longer than 350 feet from a street. Five out of the six units located in Building Seven are
outside of the 350-foot maximum from the public street to the east of this property. The furthest
door in this building is 473 feet away from a street without crossing a drive. Six of the eight units
located in Building Eight are outside of the 350-foot maximum from the public street to the south.
The furthest door in this building is 453 feet away from a street without crossing a drive. See Exhibit
A attached with this request for more detailed information. The intent of this memo is to prove that
providing a longer MWS (i) is not detrimental to the public good, (ii) promotes the general purpose
of the standard equally well or better than a plan which complies with the standard, and (iii) is the
result of exceptional physical conditions.
JustificationsJustificationsJustificationsJustifications
The Land Use Code states that the decision-maker may grant a modification of standards only if it
finds that the granting of the modification would not be detrimental to the public good; and the
decision-maker must also find that the Modification meets one of the following four criteria described
in the LUC.
No Detriment to the Public Good
The additional length of MWS being requested does not create an unsafe condition for the future
residents of the development or the general public. Four separate cut-through walk connections
are provided along the pedestrian spine to ensure adequate accessible connectivity to the rest of
the site. These connections also allow emergency personnel to access the main entrance of the
residences quickly and efficiently in the event of an emergency. Additionally, the four buildings
which are located along this longer-than standard MWS are all distinctly different building models.
This guarantees that there is no visual monotony for the public as they traverse the site along the
Major Walkway Spine. While the proposed MWS does connect to an adjacent development’s street
sidewalk, the entirety of the path of travel is located within an existing public access easement. This
public access easement was provided by the adjacent development specifically for the purposes of
providing pedestrian connectivity and access between these developments.
The additional length of the MWS does not cause any other standard or code to be violated, nor
does it create a condition on site that impacts those of others off-site. Therefore, increasing the
allowable length of a Major Walkway Spine from 350 feet to 473 feet is not detrimental to the
public good.
MINIMAL RISK. PAINLESS PROCESS. BEAUTIFUL SPACES.
o: 970.224.5828 | w: ripleydesigninc.com
RIPLEY DESIGN, INC. | 419 Canyon Avenue, Suite 200 | Fort Collins, CO 80521
Justification Criteria – Equally Well or Better Than
LUC 2.8.2(H)(1) – the plan as submitted will promote the general purpose of the standard for which
the modification is requested equally well or better than would a plan which complies with the
standard for which a modification is requested;
· LUC 3.5.2(A) Purpose – The standards in this Section are intended to promote variety, visual
interest and pedestrian-oriented streets in residential development.
· LUC 3.5.2(B) General Standard – Development projects containing residential buildings shall
place a high priority on building entryways and their relationship to the street. Pedestrian
usability shall be prioritized over vehicular usability. Buildings shall include human-scaled
elements, architectural articulation, and in projects containing more than one (1) building,
design variation.
The general purpose of the standard which is requested to be modified centers around a
visually interesting, pedestrian oriented streets and environments. The MWS designed along
the eastern boundary of this site is also adjacent to a public regional trail. The City’s regional
trails act as an arterial thoroughfare for pedestrians and bicycles. The MWS directly connects to
this regional trail system and the buildings which are out of compliance front directly onto this
pedestrian and bicycle thoroughfare. While the MWS is longer than standard, it is operating as
a frontage road for the arterial regional trail. It collects pedestrians and bikes at a slower speed
as they leave their home, and then allows access to a trail system that can connect the
residents throughout town. This scenario is a pedestrian-oriented street in its truest form,
completely prioritizing pedestrian usability over vehicular usability. There are some obvious
benefits and necessities provided by vehicular streets, which are not ignored by this plan. The
private street and alley system provided to the west of these eleven units still offers convenient
access for residents and emergency services. Allowing eleven extra residences to front a
complete bicycle and pedestrian circulation network which truly acts as a pedestrian street
promotes the Purpose of the code better than a plan which complies with the code.
Additionally, the four buildings which are located along this longer-than standard MWS are all
distinctly different building models. The Purpose of this code is intended “to promote variety”
and “visual interest.” Increasing the length of the MWS allows two distinctly different buildings
with human-scaled elements, architectural articulation and design variation to be placed along
the eastern boundary of the site. The addition of these building models promotes the Purpose
of the code better than a plan which complies with the code.
MINIMAL RISK. PAINLESS PROCESS. BEAUTIFUL SPACES.
o: 970.224.5828 | w: ripleydesigninc.com
RIPLEY DESIGN, INC. | 419 Canyon Avenue, Suite 200 | Fort Collins, CO 80521
Justification Criteria – Exceptional Physical Condition
LUC 2.8.2(H)(3) – by reason of exceptional physical conditions or other extraordinary and exceptional
situations, unique to such property, including, but not limited to, physical conditions such as
exceptional narrowness, shallowness or topography, or physical conditions which hinder the owner's
ability to install a solar energy system, the strict application of the standard sought to be modified
would result in unusual and exceptional practical difficulties, or exceptional or undue hardship upon
the owner of such property, provided that such difficulties or hardship are not caused by the act or
omission of the applicant;
Typical parcels are square or rectangular, which provides the most amount of site design flexibility.
The boundary of the subject property is triangular, with the eastern portion of the site bounded by
an existing ditch. This ditch is a defined natural feature and requires an average of a 50-foot
Natural Habitat Buffer, limiting the development potential (including streets) along the eastern
boundary. Additionally, this site acts as an infill development between two existing developments.
These developments predetermined access to the site via two public street locations and locked
this development into a predefined street pattern. These exceptional physical conditions, which are
unique to this property and are not caused by the act or omission of the applicant, create an
undue hardship by generating dimensional constraints that limit the development of another
public street along the eastern boundary. Therefore, four buildings are planned to front open
space and a Major Walkway Spine along the eastern boundary in lieu of a street. The length of this
boundary is over the 350-foot limit of a MWS, thus requiring this modification request.
DS
DS DSDSDS
DS DSDSDSDSDSDSDSDS
DSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDS
DS DSDSDSDSDSDSDSDSDSDSDS
DSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDS DSDSDSDSDSDS
DS
DS
DSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSD
S
D
S
D
S DSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDS
DS DS DS
DS DS
DSDS
DSDS
DSDSDSDS
DSDSDSDSDSDSDSDSDSDSDS
DSDSDSDS
DSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDS
DSDS
DSDS
DSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDS DSDS DSDS
DSDSDSDSDSDS DSDS DSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSD
S
D
S
D
S
D
S
D
S
DS
DSDSDSDSDS0 15 30 60
SCALE= 1'= 30'-0"
350' MAJOR WALKWAY
SPINE DISTANCE TO RIGHT
OF WAY
350' MAJOR WALKWAY
SPINE DISTANCE TO RIGHT
OF WAY ALONG EXISTING
REGIONAL TRAIL.
ADDITIONAL 123' TO MAJOR
WALKWAY SPIN ALONG
EXISTING REGIONAL TRAIL.
ADDITIONAL 103' TO MAJOR
WALKWAY SPINE CONNECTING
TO RIGHT OF WAY
350"103"123"CUT-THROUGH
WALK CONNECTION
CUT-THROUGH
WALK CONNECTION
CUT-THROUGH
WALK CONNECTION
SCHLAGEL STREETABBOTT LANEP
U
B
L
I
C
S
T
R
E
E
T
"
A
"
EXHIBIT A
ENCLAVE AT
REDWOOD