Loading...
HomeMy WebLinkAboutPOUDRE VALLEY PLAZA MIXED-USE - FDP220001 - SUBMITTAL DOCUMENTS - ROUND 2 - PLANSE AeccDbCogoPoint (AeccLand130) AeccDbCogoPoint (AeccLand130)AeccDbCogoPoint (AeccLand130) AeccDbCogoPoint (AeccLand130) AeccDbCogoPoint (AeccLand130) AeccDbCogoPoint (AeccLand130) AeccDbCogoPoint (AeccLand130) AeccDbCogoPoint (AeccLand130) AeccDbCogoPoint (AeccLand130) AeccDbCogoPoint (AeccLand130) AeccDbCogoPoint (AeccLand130) AeccDbCogoPoint (AeccLand130) A CONNECT TO EXISTING MAINLINE. COORDINATE WITH MAINTENANCE STAFF TO TURN OFF EXISTING IRRIGATION DURING CONNECTION. COIL 30 INCHES OF CONTROL CABLE IN 10-INCH ROUND VALVE BOX ADJACENT TO ISOLATION VALVE. CONNECT TO 3/4-INCH COPPER STUB DOWNSTREAM OF IRRIGATION METER. MAX FLOW 9 GPM WALL MOUNT CONTROLLER IN FIRE RISER ROOM. INSTALL CONTROL CABLE NOT ADJACENT TO MAINLINE IN CONDUIT 5.5 1 1" A 8.7 2 1" A 4.3 4 1" A 2.4 3 1" A 10 10 10 10 10 10 10 1010101010101010 101010 10 1010101010101010SSSSSSSSSSSSSSSSSSSSRS RSLSLSLSFS RS POC IRRIGATION LEGEND MAINLINE: CL200 PVC, 1-INCH SPRINKLER LATERAL: CL 200 PVC, 1-INCH DRIP TUBING: U.V. RESISTANT HDPE, 60PSI, 0.75-INCH SLEEVING: CL200 PVC, 2X NOMINAL SIZE OF CONTAINED PIPE OR WIRE BUNDLE RAIN SENSOR: RAIN BIRD WR2 ISOLATION VALVE DRIP FLUSH CAP FLOW SENSOR ASSEMBLY REMOVE CONTROL VALVE: RAIN BIRD PEB DRIP REMOTE CONTROL VALVE: RAIN BIRD XCZ-100-PRB-LC IRRIGATION CONTROLLER: RAIN BIRD ESP-LXD-IQ4A HUNTER-MP ROTATOR PRO SPRAY PRS40: 40 PSI NOZZLE 10H: 0.4 GPM, 14.0' NOZZLE 10Q: 0.2 GPM, 14.0' HUNTER-MP-STRIP PRO SPRAY PRS40: 40 PSI NOZZLE LSTR: 0.2 GPM, 15.0' NOZZLE RSTR: 0.2 GPM, 15.0' NOZZLE SSTR: 0.4 GPM, 30.0' POINT OF CONNECTION/BACKFLOW ASSEMBLY 10 10 LS RS SS RS FS POC EXISTING MAINLINE: CL200 PVC ALAL2-23-2022 TGTGPoudre Valley Plaza Mixed UseIrrigation PlanThe IrrigationEngineers2727 Alan St. Ft. Collins, CO 80524307.509.0238 www.IrrigationEngineers.comIR-1 00 10'20' 1" = 10' NORTH CITY OF FORT COLLINS NOTES 1.ANY FIELD ADJUSTMENT OR REDESIGN OF THIS IRRIGATION SYSTEM MUST CONFORM TO THE CITY OF FORT COLLINS IRRIGATION STANDARDS IN THE LAND USE CODE 3.2.1(J)(3). 2.CONTRACTOR INSTALLING THE SYSTEM MUST PROVIDE FCU AND THE OWNER WITH “AS-BUILT” DRAWINGS AFTER INSTALLATION IS COMPLETE, INCLUDING UPDATED CHARTS WITH EXISTING FIELD CONDITIONS. 3.THE SYSTEM DESIGN ASSUMES A MINIMUM DYNAMIC PRESSURE FOR THE IRRIGATION SYSTEM OF 65 PSI, AT A MINIMUM DISCHARGE OF 12 GPM AT THE 3/4-INCH POINT-OF-CONNECTION. VERIFY PRESSURE AND FLOW ON SITE PRIOR TO CONSTRUCTION. 4.READ THOROUGHLY AND BECOME FAMILIAR WITH THE SPECIFICATIONS AND INSTALLATION DETAILS FOR THIS AND RELATED WORK PRIOR TO CONSTRUCTION. 5.COORDINATE UTILITY LOCATES (“CALL BEFORE YOU DIG”) OF UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION. 6.DO NOT PROCEED WITH THE INSTALLATION OF THE IRRIGATION SYSTEM WHEN IT IS OBVIOUS IN THE FIELD THAT OBSTRUCTIONS OR GRADE DIFFERENCES EXIST THAT MIGHT NOT HAVE BEEN CONSIDERED IN THE ENGINEERING. IF DISCREPANCIES IN CONSTRUCTION DETAILS, LEGEND, NOTES OR SPECIFICATIONS ARE DISCOVERED, BRING ALL SUCH OBSTRUCTIONS OR DISCREPANCIES TO THE ATTENTION OF THE OWNER’S REPRESENTATIVE. 7.ALTHOUGH IRRIGATION COMPONENTS MAY BE SHOWN OUTSIDE PLANTING AREAS FOR CLARITY, INSTALL IRRIGATION PIPE AND WIRING IN LANDSCAPED AREAS WHENEVER POSSIBLE. 8.TREE AND SHRUB LOCATIONS AS SHOWN ON LANDSCAPE PLANS TAKE PRECEDENCE OVER IRRIGATION EQUIPMENT LOCATIONS. AVOID CONFLICTS BETWEEN THE IRRIGATION SYSTEM, PLANTING MATERIALS AND ARCHITECTURAL FEATURES. 9.USE ONLY STANDARD TEES AND ELBOW FITTINGS. USE OF CROSS TYPE FITTINGS IS NOT ALLOWED. 10.PROVIDE TO THE OWNER PRIOR TO THE COMPLETION OF THE PROJECT: TWO (2) OPERATING KEYS FOR EACH TYPE OF MANUALLY OPERATED VALVES AND TWO (2) OF EACH SERVICING WRENCH OR TOOL NEEDED FOR COMPLETE ACCESS, ADJUSTMENT AND REPAIR OF SPRINKLERS. 11.SELECT NOZZLES FOR SPRAYHEADS AND ROTORS WITH ARCS WHICH PROVIDE COMPLETE AND ADEQUATE COVERAGE WITH MINIMUM OVERSPRAY FOR THE SITE CONDITIONS. CAREFULLY ADJUST THE RADIUS OF THROW AND ARC OF COVERAGE OF EACH ROTARY SPRINKLER TO PROVIDE THE BEST PERFORMANCE. 12.INSTALL ALL ELECTRICAL POWER TO THE IRRIGATION CONTROL SYSTEM IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE AND ALL APPLICABLE LOCAL ELECTRIC UTILITY CODES. 13.IF A SECTION OF UNSIZED PIPE IS LOCATED BETWEEN THE IDENTICALLY SIZED SECTIONS, THE UNSIZED PIPE IS THE SAME NOMINAL SIZE AS THE TWO SIZED SECTIONS. THE UNSIZED PIPE SHOULD NOT BE CONFUSED WITH THE DEFAULT PIPE SIZE NOTED IN THE LEGEND. 14.INSTALL A MINIMUM OF TWO (2) APPROPRIATELY SIZED CONTROL WIRES AND ONE (1) COMMON WIRE FROM CONTROLLER LOCATION TO EACH DEAD-END OF MAINLINE FOR USE AS SPARES IN CASE OF CONTROL WIRE FAILURE. CAP END OF WIRES WITH WATER-PROOF WIRE CONNECTOR. WIRE TERMINATIONS MUST BE LOCATED IN A VALVE BOX. IN ADDITION, COIL THREE (3) FEET OF WIRE IN VALVE BOX. 15.WITHIN SIX (6) WEEKS OF THE INSTALLATION OF NEW LANDSCAPING, THE IRRIGATION SYSTEM INSTALLER SHALL RESET THE SMART CONTROLLERS TO THE NORMAL SEASONAL WATERING SCHEDULE. ALAL2-23-2022 TGTGPoudre Valley Plaza Mixed UseIrrigation PlanThe IrrigationEngineers2727 Alan St. Ft. Collins, CO 80524307.509.0238 www.IrrigationEngineers.comIR-2 NOTE: 1.FURNISH FITTINGS, PIPE AND BACKFLOW SIZED IDENTICALLY WITH NOMINAL IRRIGATION TAP SIZE. BACKFLOW PREVENTER ENCLOSURE: LE MEUR SINGLE SWING HINGE OR EQUAL REDUCED PRESSURE BACKFLOW PREVENTION DEVICE WITH FULL PORT BRONZE BALL VALVES, SAME SIZE AS TAP 3/4-INCH COPPER NIPPLE WITH CAP. CL200 PVC PIPE SLEEVE (1 OF 2) OPTIONAL 4-INCH THICK CONCRETE PAD FINISH GRADE/TOP OF MULCH TYPE K COPPER PIPE (TYPICAL) (LENGTH AS REQUIRED) COPPER FEMALE ADAPTER SCH 40 PVC MALE ADAPTER PVC MAINLINE COPPER PIPE FROM WINTERIZATION ASSEMBLY 4' MIN. COVER 12" MIN.COPPER TEE WITH 3/4-INCH RISER AND QUICK COUPLER COPPER MALE ADAPTER (2) 1-INCH TYPE K COPPER MAINLINE FROM SERVICE LINE THREADED BRONZE GATE VALVE WITH SOLID WEDGE NON-RISING STEM BRICK (1 OF 4) 6-INCH PVC CL 200 PIPE (LENGTH AS REQUIRED) STANDARD IRRIGATION VALVE BOX FINISH GRADE/TOP OF MULCH TYPE K COPPER TO BACKFLOW DECODER ID TAG STANDARD VALVE BOX WITH COVER: PENTEK OR EQUAL FINISH GRADE/TOP OF MULCH REMOTE CONTROL VALVE: 2-INCH HUNTER ICV BRICK (1 OF 4) PVC MAINLINE PIPE PVC SCH 40 MALE ADAPTER 3.0-INCH MINIMUM DEPTH OF 3/4-INCH WASHED GRAVEL CONTROL CABLE FLOMEC QS 200-15 FLOW SENSOR. TIP 45 DEG. MIN. 10X PIPE DIAMETER MIN. 5X PIPE DIAMETER 10-INCH ROUND VALVE BOX FINISH GRADE/TOP OF MULCH VALVE BOX WITH COVER: 10-INCH DIAMETER ROUND 6-INCH PVC CL 200 PIPE (LENGTH AS REQUIRED) BRICK (1 OF 2) THREADED BRONZE GATE VALVE WITH SOLID WEDGE, NON-RISING STEM PVC MAINLINE PVC SCH 40 OR WROT COPPER MALE ADAPTER (1 OF 2) NOTE: 1. NOMINAL SIZE OF GATE VALVE TO MATCH NOMINAL MAINLINE SIZE. 3" MIN. DECODER ID TAG STANDARD VALVE BOX WITH NON LOCKING COVER FINISH GRADE/TOP OF MULCH REMOTE CONTROL VALVE: AS SHOWN IN LEGEND PVC SCH 80 NIPPLE (CLOSE) PVC SCH 40 ELL PVC SCH 80 NIPPLE (LENGTH AS REQUIRED) BRICK (1 OF 4) SCH 80 NIPPLE (2-INCH LENGTH, HIDDEN) AND SCH 40 ELL PVC MAINLINE PIPE PVC SCH 40 TEE OR ELL PVC SCH 40 MALE ADAPTER PVC LATERAL PIPE 3-INCH MINIMUM DEPTH OF 3/4-INCH WASHED GRAVEL CONTROL CABLE: 30-INCHES IN VALVE BOX WATERPROOF CONNECTORS (4) PVC BALL VALVE: SAME SIZE AS RCV NOTE: FOR SPRINKLERS OVER 5 GPM USE PREFABRICATED PVC SWING JOINT SPRINKLER HEAD: AS CALLED OUT IN LEGEND FINISH GRADE SWING JOINT: 1/2-INCH FLEX TUBING WITH LASCO SWING JOINT FITTINGS SERVICE TEE OR ELL LATERAL PIPE WATERPROOF CONNECTORS (4) ID TAG DRIP REMOTE CONTROL VALVE KIT: AS SHOWN IN LEGEND FINISH GRADE JUMBO VALVE BOX SCH 80 THREADED NIPPLE SCH 40 ELL BRICK SUPPORTS (4) 3/4" WASHED GRAVEL MAINLINE PE DRIP TUBING/ PVC DRIP MANIFOLD DECODER 2 WIRE CONTROL CABLE NOTE: 1.MAXIMUM LENGHT OF 1 4" DISTRIBUTION TUBING IS 5-FEET 2.STAKE ENDS OF DISTRIBUTION TUBING ON UPHILL SIDE OF PLANT. SHRUB(2 GPH): 2 x XB-10PC EMITTER WITH 1 4" DISTRIBUTION TUBING DECIDUOUS TREE(8 GPH): 4 x XB-20PC EMITTER WITH 1 4" DISTRIBUTION TUBING CONIFEROUS TREE(6 GPH): 3 x XB-20PC EMITTER WITH 1 4" DISTRIBUTION TUBING POLYETHYLENE DRIP LATERAL GRASS / GROUNDCOVER PLANTINGS (1 GPH): 1 x XB-10PC EMITTER WITH 1 4" DISTRIBUTION TUBING BRICK (1 OF 2) FINISH GRADE/TOP OF MULCH 6-INCH ROUND VALVE BOX WITH COVER FLUSH PLUG WITH HOSE THREAD CAP DRIP IRRIGATION LATERAL 3-INCHES MIN. OF 3/4-INCH GRAVEL 2 MASTER VALVE ASSEMBLY1BACKFLOW PREVENTION ASSEMBLY 4 REMOTE CONTROL VALVE ASSEMBLY 5 SPRINKLER ASSEMBLY3ISOLATION GATE VALVE ASSEMBLY 6 DRIP REMOTE CONTROL VALVE ASSEMBLY 7 TYPICAL EMITTER PLACEMENT & SCHEDULE 8 DRIP FLUSH CAP ASSEMBLY