Loading...
HomeMy WebLinkAboutWORTHINGTON STORAGE - PDP220003 - SUBMITTAL DOCUMENTS - ROUND 1 - PROJECT NARRATIVE MINIMAL RISK. PAINLESS PROCESS. BEAUTIFUL SPACES. o: 970.224.5828 | w: ripleydesigninc.com RIPLEY DESIGN, INC. | 419 Canyon Avenue, Suite 200 | Fort Collins, CO 80521 Worthington StorageWorthington StorageWorthington StorageWorthington Storage Project NarrativeProject NarrativeProject NarrativeProject Narrative 02/02/02/02/23232323/2022/2022/2022/2022 IntroductionIntroductionIntroductionIntroduction The purpose of this Project Narrative is to clearly communicate the intent behind the Worthington Storage PDP, how it complies with the Fort Collins Land Use Code, and describe the principles of City Plan that support this type of development. This appliaction is for a combined Overall Development Plan (ODP) and Project Develompent Plan (PDP). The ODP attached is included to enable the immediate development of a storage facility on Lot 1, while setting the stage for the redevelopment of the now vacant AMC movie theater on Lot 2. Uses for future development of Lot 2 will be selected from the allowable uses in the Employment District during a separate Project Development Plan (PDP) application. Lot 2 is not a part of this PDP application. A Conceptual Review meeting was held by the City on 04/01/2021 and a Neighborhood Meeting was held on 07/07/2021. The upscale Red Rocks Storage Facility proposes to replace a portion of the parking lot of the former AMC movie theater near Drake and Shields in the Centre for Advanced Technology PUD. The proposed self-storage facility is approximately 90,000 rentable square feet in total consisting of a three-story structure with individual storage units ranging in size from 25 to 300 square feet and flanked by three (3) one-story buildings screening the loading area. The applicant, Strategic Storage Partners, LLC has over 30 - years of experience in the self- storage industry. Through the years they have contributed to innovative industry advances in self-storage as important complementary amenities for residential and commercial development. One example of this is the tenant conference room which is provided to tenants as a a space for alternative business to occur. It also provides a space for tenants to use in liue of a traditional retail space while generating very little parking demand. Additional amenities provided at the facility include Wi-Fi connectivity, electric car charging stations, bike racks and bike repair stations. Access to the property for tenants is provided via iPhone application and or passcodes. Access is limited to normal business hours and monitored by digitally stored recording cameras. Strategic Storage Partners has recently completed a similarly sized and architecturally similar self-storage facility in Golden, Colorado, a tour of which best presents the best of quality of design and the ease and efficiency of operations intended for the proposed project. As homes become smaller, apartment rents increase, and commercial users shift to off-site inventory storage, the demand for self-storage at convenient locations is growing rapidly. Accordingly, a demand potential analysis for the proposed self-storage use on the subject property has been completed by THK Consultants. This analysis, considering existing and potential competition, indicts a strong demand for a state-of-the-art self- storage facility at this location. Among other factors, the study considers personal income levels, employment, MINIMAL RISK. PAINLESS PROCESS. BEAUTIFUL SPACES. o: 970.224.5828 | w: ripleydesigninc.com RIPLEY DESIGN, INC. | 419 Canyon Avenue, Suite 200 | Fort Collins, CO 80521 population, and household income with a 10-to-15-minute drive. Within the mix of the surrounding commercial/ residential development, there does not appear to be another suitable property to address the identified demand for high quality, state-of-the-art self- storage in midtown Fort Collins. Staff is encouraged to visit this site or the web site at https://redrocksstorage.com/. Land UseLand UseLand UseLand Use The property is located within the E – Employment Zoning District. Enclosed mini storage is permitted as a secondary use under the land use standards. The Employment District dictates that secondary uses may occupy no more than 25% of the total gross area of the development plan. The contiguous E Zoning District that includes Lot 1 of the Centre for Advanced Technology consists of approximately 221 acres with 52-acres of the 55-acres allowed for secondary uses being currently utilized. Assuming Lot 1 and Lot 2 of this development develop as secondary uses, 24.76% of this Employment district is considered a secondary use, which is within the allowed amount by the Land Use Code. A detailed Secondary Use Study has been included with this application for further detail. Site DesignSite DesignSite DesignSite Design The existing 3.2-acre lot contains a vacant 18,000 square foot movie theater and associated parking lot. A private drive bisects the parking lot and connects to adjoining properties, conveniently separating the existing theater building from the parking lot. This application proposes to subdivide the existing lot into two individual lots by placing a new property line aligned with the centerline of that private drive. The proposed three-story building attempts to front Worthington Circle to the extent reasonably feasible despite an existing drainage facility on the northern corner of the site. Due to the geometry of the arced right- of-way of Worthington Circle, the fifteen-foot Build-To Line is touched on the southeastern corner of the building, however the 50% of the buliding frontage does not exist within the Build-To-Line. Additionally, the existing detention pond to the north creates the need for a noncompliant front yard and, per LUC 3.5.3.(C)(2)(d)4., this standard is to not required to be met. The main entrance to the building is oriented north towards the existing private drive and a connecting walk is provided to the private drive and Wothington Circle. Vehicular access is provided from the private drive bounding the northern side of the property, which leads to a small parking area with five spaces and security gate. Customers and emergency services may drive into the facility via a 24-foot-wide drive which loops around the building to the south and connects to the private drive which bisects the two new lots. The project provides eight parking spaces for its own use, as well as eleven parking spaces on the south side of the proposed building, which are for the benefit of a future user when the vacant theater is redeveloped. A twenty-six-foot-wide private drive borders the south of the building and provides Aerial Access per the International Fire Code. LanLanLanLandscape Designdscape Designdscape Designdscape Design There is limited existing landscape and open space within the property consisting of small parking islands and a detention pond with young trees. The landscape is designed to anchor the building through the use of MINIMAL RISK. PAINLESS PROCESS. BEAUTIFUL SPACES. o: 970.224.5828 | w: ripleydesigninc.com RIPLEY DESIGN, INC. | 419 Canyon Avenue, Suite 200 | Fort Collins, CO 80521 foundation plantings and provide a pedestrian sense of scale along the Worthington public right-of-way via a double tree lined detached walk. Conifer trees are proposed along the façade facing Worthington as well to further aid in articulating and mitigating the mass of the building. Larger coniferous trees are also proposed on the western edge of the property where abutting an existing non-conforming residence. While the project is proposing to remove forty existing trees, thirty-six of them are Ash trees which are recommended to be removed by the City in anticipation of the emerging Emerald Ash Borer. All removed existing trees will be mitigated per Fort Collins requirements. As this storage facility is a proposed commercial use and not an existing industrial use, there are no specific landscape buffers required by this property per the Purpose of the buffering standards in LUC 3.8.26(B) which is to “…separate residential land uses and high occupancy building units from existing industrial uses…” Additionally, the buffer yard requirements found in LUC 3.8.30(F)(1) do not apply as this section is only applicable to multifamily and single-family-attached uses. Architectural DesignArchitectural DesignArchitectural DesignArchitectural Design The property to the east is the Drake Marketplace, which consists of several retail stores and restaurants. To the west there are two residential multi-family homes along S Shields Street. The proposed development and architecture strive to complement the existing commercial buildings while being sensitive to the nonconforming residential uses along Shields. The site plan will also ensure there is a smooth transition between the commercial and residential uses and minimize the impact on the adjacent residential properties. The transition is achieved through a combination of landscape designed (as mentioned above) and transition of building heights. Land Use Code Section 3.5.1 requires that “proposed buildings and uses are compatible when considered within the context of the surrounding area.” And (C) “Buildings shall either be similar in size and height, or, if larger, be articulated and subdivided into massing that is proportional to the mass and scape of the other structures, if any,… abutting or adjacent to the subject property…” There is one existing residential building adjacent to this site. It steps from two stories down to one story and is 2,639 square feet according to Larimer County assessor. Our project proposes a three-story building near the large vacant movie theater with two, one-story buildings on the west side of the project closest to the residential building and auto repair shop. The proposed one-story buildings are 2,500 square feet, thus compatible with the scale and mass of the existing two-story nonconforming residential buildings. Utilities and DrainageUtilities and DrainageUtilities and DrainageUtilities and Drainage The proposed project is served by the City of Fort Collins Utilities, including water and wastewater. There is an existing 8” water main that loops the existing site with connections to Worthington Circle. Existing fire hydrants are located at the north and southwest entrances to the site, which provide adequate coverage for the proposed development. There is also an 8” sanitary sewer main that runs through the center of the site, located in the parking area just to the north of the existing building. A water, fire, and sanitary service will be installed for the proposed 3-story building. Existing gas and electric lines are located adjacent to Worthington Circle. MINIMAL RISK. PAINLESS PROCESS. BEAUTIFUL SPACES. o: 970.224.5828 | w: ripleydesigninc.com RIPLEY DESIGN, INC. | 419 Canyon Avenue, Suite 200 | Fort Collins, CO 80521 Stormwater runoff currently discharges to an existing 15-inch storm drain located at the northern corner of the site. This existing storm drain connects to an existing storm network in Centre Avenue which ultimately discharges to Spring Creek. Drainage patterns from surrounding properties will be maintained and conveyed to the existing outfall location. Existing detention storage is provided with a detention pond adjacent to Worthington Circle and ponding in the existing parking lot. Volume will be maintained, but detention ponds and conveyance methods will be modified with the proposed site. A system of storm drains, underground chambers and detention ponds will be used to meet the cities LID and detention requirements. Ownership and Ownership and Ownership and Ownership and MaintenanceMaintenanceMaintenanceMaintenance The property owner/developer will be responsible for maintenance of all landscaping, internal private drives and other features and amenities of the property. Neighborhood MeetingNeighborhood MeetingNeighborhood MeetingNeighborhood Meeting The main issue that arose from the neighborhood meeting was the impact to shared parking in the area due to the proposed development. There are not any shared parking agreements currently in place and this project therefore this project is not removing approved parking from adjacent uses. The proposed development will be providing 8 parking spaces per LUC minimums and maximums associated with this use, along with an additional 11 spaces for the benefit of future uses on Lot 2. The access to the main storage access will be gated with no exterior storage access. On-street parking along Worthington Circle will not be affected during or after construction and can still be used by adjacent uses. City Plan and PolicyCity Plan and PolicyCity Plan and PolicyCity Plan and Policy Red Rocks Self-Storage is supported by the following Principles and Policies found in the Fort Collins City Plan, adopted April 16, 2019. Principle LIV 2: Promote infill and redevelopment LIV 2.1 – Revitalization of Underutilized Properties - Support the use of creative strategies to revitalize vacant, blighted or otherwise underutilized structures and buildings, including: Infrastructure improvements & Infill of existing surface parking lots · The proposed overall development plan will replace the existing parking lot with a Self-Storage facility, as well as create a separate lot that will encourage the re-development of the existing theater building. Principle EH 1: Foster a vibrant, resilient and inclusive economy EH 1.1 – Employment Base-Support the enhancement of the community’s economic base and primary job creation by focusing on retention, expansion, incubation, and recruitment effort that create jobs and import income of dollars to the community. MINIMAL RISK. PAINLESS PROCESS. BEAUTIFUL SPACES. o: 970.224.5828 | w: ripleydesigninc.com RIPLEY DESIGN, INC. | 419 Canyon Avenue, Suite 200 | Fort Collins, CO 80521 · The proposed development plan will encourage the re-creation of jobs in the area from the vacant theater. The planned self-storage facility will employ at least two people and with the creation of lot 2, the re-purposed theatre building will encourage the expansion of business and future employment in the area. Principle ENV 6: Manage water resources in a manner that enhances a protects water quality supply and reliability LIV 6.6 – Low Impact Development-Pursue and implement Low Impact Development as an effective approach to address stormwater quality and impacts to streams by urbanization. LIV 6.7 – Best Management Practices-Utilize stormwater facility design criteria that follow national Best Management Practices · The Proposed development does not propose to increase the impervious area on the property. The existing property was constructed with no water quality treatment or low impact development. With the modification of the parking lot, the new development will utilize BMP’s and LID controls to ensure water quality treatment during construction and to treat the existing stormwater runoff. Principle T 3: Lead transportation innovation by exploring and utilizing emerging and transformative systems and technologies T 3.9 – Electric Vehicles-Encourage, prioritize, and support the purchase of electric vehicles through the design, management, outreach, education, policy updates, broad-based coordination, incentives and operations of streets and wayside infrastructure such as electric-vehicle charging station. · Electric vehicle charging stations will be implemented in the design of the self-storage facility. Principle T 6: Support bicycling as a safe, easy, and convenient travel option · The northwest area of Fort Collins is severely underserved for storage. Currently, residents have to drive across town to access storage units. By providing storage near homes, bicycling and walking is encouraged or at a minimum it is a reduction of miles driven. T 6.5 – Facility Maintenance-Identify opportunities for additional year-round maintenance of bicycle facilities to provide safe bicycling in winter months. · Bicycle maintenance facilities will be implemented in the design of the self-storage facility. This will help build upon the connected bicycle facility the Fort Collins and in this local commercial retail area. MINIMAL RISK. PAINLESS PROCESS. BEAUTIFUL SPACES. o: 970.224.5828 | w: ripleydesigninc.com RIPLEY DESIGN, INC. | 419 Canyon Avenue, Suite 200 | Fort Collins, CO 80521 Housing Strategic Plan Red Rocks Self-Storage is supported by the prioritized strategies found in the Housing Strategic Plan, adopted in March of 2021. The vision of the Housing Strategic Plan is that: “Everyone has healthy, stable housing they can afford.” Development and land costs continue to rise and house and lot sizes continue to shrink. More people are choosing to fill up the spare room with a roommate rather than possessions. As basements are finished for aging parents, or kids moving home after college, the storage capacity decreases. In order to store the equipment for active lifestyles, side jobs, and miscellaneous storage, off-site options must be utilized. Specifically, our project supports the following strategies: (7) Remove barriers to the development of Accessory Development Units Community Recommendations Alignment - Explore housing types to include smaller homes and cooperative housing and relax restrictions in the Land Use Code