Loading...
HomeMy WebLinkAboutWORTHINGTON STORAGE - ODP - ODP220001 - SUBMITTAL DOCUMENTS - ROUND 1 - UTILITY PLANSST STSTS T ST S T S T STSTSSSSSSSSSSSSSSSSSSSSSSSSSSSSS S SSS S SSSSSSCVAULTELECSSSELECCELECEDFESWHYDHYDWCSWH2OHYDDDDTCONTROLIRRWWWWWWWWWWWWWWWWWWWGEE EEEEEEEEEGGGGXXCTVCTVCTVCTVCTVCTVCTVT T TT EEEEEEEE EEE EEEEEEEEEVAULTF.O.TALL DENTIST LLC1001 CENTRE AVE(EMPLOYMENT DISTRICT)DODSANITY LLC1013 CENTRE AVE(EMPLOYMENT DISTRICT)KATSCH24 LLC1007 CENTRE AVE(EMPLOYMENT DISTRICT)AWEIDAPROPERTIES INC2500 S SHIELDS ST(EMPLOYMENTDISTRICT)AWEIDAPROPERTIES INC2514 S SHIELDS ST(EMPLOYMENTDISTRICT)WARPAL LLC1044 W DRAKE RD(EMPLOYMENTDISTRICT)MARKET CENTRERETAIL ASSOCIATIONMCDRAKE LLC1002 W DRAKE RD(EMPLOYMENTDISTRICT)TWO PAULS LLC932 W DRAKE RD(EMPLOYMENTDISTRICT)WINSLOW REALESTATE LLC909 CENTRE AVE(NEIGHBORHOODCOMMERCIALDISTRICT)ROBERT WILSON 2526WORTHINGTON CIRCLE(NEIGHBORHOODCOMMERCIAL DISTRICT)COLUMBINE MEDICAL REALESTATE LLC915 CENTRE AVE(NEIGHBORHOODCOMMERCIAL DISTRICT)CENTRE AVENUE(COLLECTOR STREET)WORTHINGTON CIRCLE(CONNECTOR LOCAL STREET)S SHIELDS STREET(4-LANE ARTERIAL STREET)W DRAKE ROAD(4-LANE ARTERIAL STREET)ESECONDARY USES±1.98 ACRES(UTILITY, DRAINAGE, ANDACCESS EASEMENT)PARCELAPARCELBEPRIMARY/SECONDARYUSES±1.22 ACRESEXISTING BUILDINGEXISTING BUILDINGPRIVATE ACCESS ROADPRIV ATE ACCESS ROADPRIVATE ACCESS ROAD UTILITY, DRAINAGE, ANDACCESS EASEMENTUTILITY, DRAINAGE, ANDACCESS EASEMENT54'RIGHT-OF-WAYMARKET CENTRERETAIL ASSOCIATIONTWO PAULS LLC932 W DRAKE RD(EMPLOYMENTDISTRICT)EXISTING 8" SANITARY MAINEXISTING 8"WATER MAINEXISTING 8"WATER MAINEXISTING 8" SANITARY MAINEXISTING SANITARY MAINDRAKE RETAIL REALESTATE LLC902 W DRAKE RD 7(NEIGHBORHOODCOMMERCIAL DISTRICT)RAINTREECOMMERCIAL PUDRAINTREECOMMERCIAL PUDDETENTIONPONDDETENTIONPONDEXISTING 2" WATER SERVICEEXISTING 6" SANITARY SERVICEEXISTING 6" FIRE SERVICEEXISTING 8" WATER MAINEXISTING FIREHYDRANTEXISTING FIREHYDRANTMUPMASTER UTILITY PLAN1CALL UTILITY NOTIFICATION CENTER OFCOLORADOKnow what'sbelow.before you dig.CallRLEGEND:WSSNOTES:1.ALL WATER LINES AND SANITARY SEWER LINES ARE PART OF THE CITY OF FORTCOLLINS.2.PROPOSED SERVICES CONNECTIONS ARE PLANNED TO BE MADE FROM EXISTINGUTILITY MAINS. PROPOSED UTILITIES SHOWN WITH THE MASTER UTILITY PLAN ARECONCEPTUAL IN NATURE AND ARE SUBJECT TO CHANGE WITH SUBSEQUENTPROJECT DEVELOPMENT PLAN APPLICATIONS.4.ACCESS POINTS SHOWN ON THE ODP ARE APPROXIMATE. EXACT LOCATIONS TO BEDETERMINED DURING THE PDP PROCESS. TWO POINTS OF FIRE ACCESS HAVE BEENPLANNED TO SERVICE DEVELOPMENT.5.PLANNING AREA ACREAGES AND BOUNDARIES ARE PRELIMINARY AND SUBJECT TOCHANGE WITH DETAILED PLANNING.6.REFER TO ODP AND MASTER DRAINAGE PLAN FOR ADDITIONAL INFORMATION.NORTH( IN FEET )01 INCH = 50 FEET5050100150SheetThese drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc.NOT FOR CO N S T R U C T I O N REVIEW SE T E N G I N E E R N GI EHTRON R N FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.comof 1WORTHINGTON SELF STORAGE