Loading...
HomeMy WebLinkAbout504 S WHITCOMB STREET, CARRIAGE HOUSE - FDP210006 - SUBMITTAL DOCUMENTS - ROUND 3 - SUPPORTING DOCUMENTATION Highland Development Services, Inc. 6355 Fairgrounds Avenue, Suite 100 | Windsor, CO 80550 | 970.674.7550 Memorandum TO: Robert Kirkpatrick FROM: Adele Bartel, E.I., Jason Claeys, P.E. DATE: 10/26/21 PROJECT: 504 S. Whitcomb St. HDS JOB NO: 21-1039-00 SUBJECT: Water Fixture Unit Summary This memo has been prepared to document the water fixture units at 504 S. Whitcomb St associated with the existing residence and the addition of the proposed alley house and estimated water demand. The proposed alley house at 504 S. Whitcomb St adds a total of 7 new plumping fixtures. Using the load values from the 2018 International Plumbing Code, it was determined that the proposed fixture units, in addition to the existing fixture units, would require a ¾” water service. It is recommended that the service line to the alley house be upsized to a 1” line, a minimum of 5 ft beyond the meter, to assist in reducing pressure loss due to the length of service. See the attached spreadsheet for Plumbing Fixture Unit Calculations. Please do not hesitate to email jclaeys@highland-ds.com or call 970.674.7570 if there are any questions. NUMBER OF EXISTING FIXTURESNUMBER OF FIXTURES TO BE REMOVEDNUMBER OF NEW FIXTURES(Alley House)TOTAL NUMBER OF PLUMBING FIXTURES(A-B+C)RESIDENTIAL OR NON-RESIDENTIALRESIDENTIAL FIXTURE UNITSTOTAL WATER FIXTURE UNITS(RES = D X F)(NON RES=D X G)(A) (B) (C) (D) (E) (F) (H)2 1 3 Residential 2.2 6.6213Residential1.44.201.40213Residential0.72.1213Residential1.44.2213Residential1.44.2010213Residential1.44.2112Residential3602002000000000000000000000000000000031.53/4 inch44 2588 41283 81525 1291952 3214599 6416384 12018648 28016"8"Note: Fixture Units shown are taken from the2018 International Plumbing Code Load Values.3/4"1"1.5"2"3"4"Ice Machine, 1" line sizeTOTAL FIXTURE UNITS (SUM COLUMN)Water Meter SizeMaximum Fixture Unit CountMaximum Gallon Per Minute DemandREQUIRED METER SIZE(2)Dip WellGrease Trap, InterceptorIndustrial ClotheswasherIce Machine, 3/8" line sizeIce Machine, 1/2" line sizeIce Machine, 3/4" line sizeIndustrial DishwasherBeverage Hook-upDrinking FountainSink (Service/Mop/Janitor)Emergency Eye WashEmergency ShowerHose Bibb/Sill CockFoor Drain/Floor SinkSand Trap, InterceptorNON RESIDENTIALFlush Valve ToiletUrinalShower Stall (per head)Sink (Bath, Hand, Bar, Lab)Sink (Kitchen/Compartment)DishwasherIce Machine, 3/8" line sizeWasher/Laundry Tub/Utility Sink504 S Whitcomb St - Alley HousePLUMBING FIXTURE UNIT CALCULATION WORKSHEETTYPE OF FIXTURERESIDENTIAL OR NON RESIDENTIALTank ToiletBathtub/Bathtub Shower Combo