HomeMy WebLinkAboutHEWLETT-PACKARD MODULAR OFFICE BUILDING - I-L SITE PLAN REVIEW - 54-88D - SUBMITTAL DOCUMENTS - ROUND 1 - APPLICANT COMMUNICATIONRELEASED SPECIFICATI�
HEWLETT PACKARD
33,320 S.F. MODULAR BUILDING
1.0 FRAME
a sa
• ■ a■ s■ an
K)
Building Svstems, Ltd.
1.1
TYPE:
Outrigger.
1.2
BEAM:
M12x11.8# I-beam
1.3
OUTRIGGER:
14 ga. formed steel "Z" installed @ 48" o.c.
1.4
CROSSMEMBER:
14 ga. formed steel "Z" installed @ 48" o.c.
1.5
HEADERS:
M12x11.8 I-beam with square ends installed on front and rear.
Double outrigger header segments below columns.
1.6
HITCH:
Demountable with 2-5/16" coupler and elevating jack.
1.7
AXLES:
All units shall have quad underslung 5000# with electric brakes.
Sidewall and restroom units shall have five axles.
1.8
TIRES:
8:00 x 14.5 8 ply rated on all outside units.
1.9
PAINT:
Black asphalt based on entire assembly less axles.
2.0 FLOOR
2.1 BOTTOM BOARD: .040 one piece rolled continuous construction board "Polymax" type
GW with a Class "A" fire classification.
2.2 INSULATION: R-1 1 (3-1 /2") foil faced fiberglass baits.
2.3 JOISTS: 2X6 #2 SYP installed transverse @ 16" o.c.
2.4 PERIMETER RAILS: Double 2x6 #2 SYP on all sides.
2.5 DECKING: Single layer 3/4" plywood tongue and groove underlayment grade
plywood installed perpendicular to the framing members.
2.6 COVERING: .085 vinyl roll goods shall be installed in restrooms, janitors closet,
computer room and NCS room.
Roll goods shall be Armstrong standard Corlon commercial sheet
flooring "Brigatine". (Plant to install roll goods in restrooms and
janitors closet) Cove roll goods up 5" in the restrooms and janitors
closet.
Color to be #86368 Denim
HEWLET rISPE 1 Rev061995
®1400 U.S. HIGHWAY 3S7 SOUTH miRMANSFIELD, TEXAS 76063 ■i817.473-9376 ME 817-473-3485
RELEASED SPECIFICATI(e
HEWLETT PACKARD
33,320 S.F. MODULAR BUILDING
■ ■■
ME an
�MT H
Building Systems, Ltd.
26 oz. level loop, action back Olefin, direct glue down, commercial
carpet shall be installed in all other areas. (Field installed)
Color shall be Paramount #721 Kings Blue
2.6 MISCELLANEOUS: FloorAccess Hatch: Provide (1) 36"x36" access hatch in NCS room.
3.0 EXTERIOR WALLS
3.1 TYPE: UBC framing.
3.2 STUDS: 2x4 #2 SYP @ 16" o.c. at 238' sides and 2x4 #2 SYP at 12" o.c. at
140' sides.
3.3 BOTTOM PLATE:
Single 2x4 #3 SYP.
3.4 TOP PLATE:
Double 2x4 #3 SYP.
3.5 HEADERS:
Double 2x4 #2 SYP on edge with 1 /2" CDX plywood filler, and double
2x6 #2 SYP on edge with 1 /2" CDX plywood filler at 6'-0" opening.
3.6 WALL HEIGHT:
All walls to extend full height to peak of roof to provide a concealed
roof line. (parapet wall)
3.7 FIRE BLOCKS:
2x4 installed @ ceiling line in all walls.
3.8 INTERIOR FINISH:
5/8" type "X" unfinished drywall installed in factory. All drywall to
receive tape, bed, and monolithic finish vinyl installed on site.
Color shall be #6-2005
3.9 INSULATION:
R-.11 (3-1./2") foil faced fiberglass batts installed to ceiling line.
3.10 SHEATHING:
15# felt entire exterior.
3.11 SIDING:
7/16" L-P "Innerseal" exterior OSB plywood with grooves @ 8" o.c.
(Innerseal shall be installed from bottom of floor to a height of 8'-0")
Color shall be Pittsburgh #72-1 13 Poplar
Color band of 26 ga. "R" panel shall be provided on parapet wall,
from top of innerseal to top of exterior walls.
Color shall be Burnished Slate
1 /2" plywood sheathing shall be installed under 26 ga. "R" panel
fascia at full perimeter of building.
HEWLETrISPE
2 Rev061995
■1400 U.S. HIGHWAY 287 SOUTH ■■ NIANSFIELD. TEXAS 76063 ■i 817 .473-9376 IN FAX 817.473-3485
RELEASED SPECIFICATIAl ■ ■■ ®■ i■
HEWLETT PACKARD MTECH
33,320 S.F. MODULAR BUILDING Building Systems, Ltd.
3.12 TRIM: 4" textured lap trim @ windows and doors.
Color shall be Burnished Slate
4" textured lap trim @ corners.
Color shall be Pittsburgh #72-11 3 Poplar
8" textured lap trim @ bottom.
Color shall be Pittsburgh #72-1 13 Poplar
3.13 SCUPPER BOX: Provide 26 ga. painted scupper box with painted downspouts as
shown on plans.
Color shall be Burnished Slate
3.14 SKIRTING: Same material as used for exterior siding installed to grade with vents
and access doors. (Skirting to be installed after H-P underfloor
outfittings.)
Note: Exterior South wall as noted on plans shall be 1-hour fire rated
for H-P installed connecting corridor.
4.0 INTERIOR WALLS
4.1
STUDS:
2x4 #2 SYP @ 16" o.c.
4.2
BOTTOM PLATE:
Single 2x4 #3 SYP.
4.3
TOP PLATE:
Double 2x4 #3 SYP.
4.4
HEADERS:
Double 2x4 #2 SYP on edge with 1 /2" CDX plywood filler.
4.5
COLUMNS:
3"x3" x 3/16" tube steel.
4.6
WALL HEIGHT:
All walls to be full height with solid blocking to roof deck above wall.
4.7
FINISH:
5/8" type "X" unfinished drywall installed in factory. All drywall to
receive tape, bed, and monolithic finish vinyl installed on site.
Color shall be #6-2005
9' fiberglass reinforced Class "B" panel laminated to 5/8" type "X"
HEWLETT3.SPE 3 Rev061995
01400 U.S. HIGHWAY 2g7 SOUTH ■■ NIANSFIELD. TEXAS 7i3Oh ■� R17. 173-93%6 iiF.�l S17 ■473-3485
RELEASED SPECIFICATIO
HEWLETT PACKARD
33,320 S.F. MODULAR BUILDING
■ ■■
ME K)
Building Systems, Ltd.
gypsum in janitors closet and restrooms. (On plumbing walls only in
restrooms, vinyl to be site installed in all other areas of restroom.)
Color shall be White.
4.8 INSULATION: R-1 1 (3-1 /2") unfaced fiberglass batts.
Note: Interior walls in corridor shall be 1-hour fire rated.
5.0 MOULDING
5.1 BASE: 4" vinyl cove base throughout shall be field installed.
Manufacturer/Color shall be Roppe #595 Lt. Gray
5.2 VERTICAL: N/A
5.3 CEILING: N/A
5.4 WINDOWS: The jambs of all windows shall be finished the same as the walls.
6.0 ROOF
6.1 RAFTERS:
6.2 RAILS:
6.3 OVERHANGS:
6.4 STEEL TRUSS:
6.5 CEILING
6.6 CEILING HEIGHT:
6.7 SUB -CEILING
AT CORRIDOR:
6.8 INSULATION:
HEWLETTISPE
2x8 #2 SYP installed @ 16" o.c.
Rafters shall be installed so as to provide a 1 /4" IN 12 pitch.
2x8 #2 SYP.
N/A
Open web steel truss designed for required spans on each side of
mating line.
2x4 acoustical panel in suspended T-grid system. Ceiling shall be
"Capaul" nubby open plan with foil backing field installed.
The finished ceiling height throughout the building shall be 9'-0".
5/8" type "X" gypsum on face of walls above ceiling in corridor for 1
hour fire rating- solid wood blocking with 5/8" type "X" gypsum cover
shall be installed above walls to roof deck.
R-19 (6") foil faced fiberglass batts on ceiling, shall be field installed.
4 Rev061995
s1400 U.S. HIGHWAY ?87 SOUTH ■s MANSFIELD. TEXAS 76063 Ni S17.473-9376 iiFA\ 817 ■ 473-3485
RELEASED SPECIFICATI&
0
HEWLETT PACKARD
33,320 S.F. MODULAR BUILDING
6.9 DRAFT STOP: Installed in ceiling cavity as noted on drawings.
6.10 SHEATHING: 5/8" CDX plywood.
■ ■■
�MTECH
■■ ■■ ■■
Building Systems, Ltd.
6.11 ROOFING: 45 mil white EPDM fully adhered attached over a layer of 1 /2"
densglass.
6.12 ATTIC VENTILATION: Each draft stop space shall receive a curb mounted roof top
ventilation rated at 550 cfm nominal. Curb shall be 10" deep, nominal.
7.0 EXTERIOR DOORS
7.1 DOORS: (1) pair 1-3/4"x36"x84" 20 ga. hollow core commercial steel with 20
minute fire rating at south wall.
(1) pair 36"x84" aluminum extruded storefront assembly with 1 /4"
bronze tinted tempered insulated glazing.
(2) 36"x84" aluminum extruded storefront assembly with 1 /4" bronze
tinted tempered and insulated glazing.
7.2 FRAMES: All exterior steel doors shall be equipped with 16 ga. knockdown
frames.
All storefront doors shall be equipped with manufacturers standard
extruded aluminum frames.
7.3 HARDWARE: All exterior steel doors shall be equipped with 1-1/2 pr. of 4-1 /2"x4-
1 /2" ball bearing, non -removable in butt hinges, full weatherstrip,
threshold, auto door bottoms, and a Rixson #997 electromatic hold
open wired to fire alarm panel.
Storefront doors shall be equipped with manufacturers standard.
7.4 LOCKSETS: Exterior steel doors shall be equipped with a Von Duprin panic
hardware.
Storefront doors shall be equipped with a securitron TS8-3 touch
sense crashbar. (12-24 volt power)
7.5 CLOSER: A Norton hydraulic closer with back check feature shall be provided
on all exterior steel doors.
HEWLETTISPE
Storefront doors shall be provided with manufacturers standard
concealed closer.
5 Rev061995
E1400 U.S. HIGHWAY 287 SOUTH sai\LANSFIELD, TEXAS/UVAX �-817.473-34b5
M ME
• RELEASED SPECIFICATI(A an
HEWLETT PACKARD AMT H
33,320 S.F. MODULAR BUILDING Bujldino, Systems, Ltd.
7.6 FINISH: The interior and exterior side of the steel doors and frames shall be
painted to match adjacent exterior trim. (Burnished Slate)
Storefront doors to be anodized bronze finish.
8.0 INTERIOR DOORS
8.1 DOORS: 1-pair 1-3/4"x 36"x 84" 20 ga. hollow core commercial steel in
computer room.
1-3/4" x 42" x 84" 20 ga. hollow core commercial steel in NCS
room.
1-3/4"x36"x84" 20 ga. hollow core commercial steel in all other areas.
Doors in corridor shall have 20 minute fire label.
8.2 FRAMES: All interior doors shall be set in 16 ga. knockdown steel frames.
8.3 WINDOWS: 6"x30" 1 /4" tempered glass in conference and litigation rooms.
24"00" tempered safety glass in computer and NCS rooms.
Windows in corridor shall be 1 /4" wired safety glass.
8.4 HARDWARE: All interior doors shall be equipped with 1-1/2 pr. of 4-1 /2"x4-1 /2"
mortise hinges, floor mount stops and silencers. Restroom doors shall
be equipped with push/pull plates. Double doors shall be equipped
with head and foot bolts on inactive door.
8.5 LATCHSETS: All doors to have Schlage passage latch with "Plymouth" knob and
26D finish.
8.6 CLOSER: A hydraulic closer shall be provided on all interior doors.
8.7 FINISH: All interior doors and frames shall be painted with Sherwin-Williams
#N-1-2-48 3-2-R1-1 +1 Nightingale.
9.0 WINDOWS
9.1 TYPE: 36"x60" aluminum fixed with insulated bronze glass and bronze
anodized frames.
9.2 COVERING: All exterior windows shall be provided with inset 1 " mini -blinds "Bali"
Classics Series 3000.
Color shall be #081 Mushroom
HEWLETTISPE 6 Rev061995
at400 U.S. HIGHI�'AY 287 SOUTH ■■\IA\SFIELD. TEXAS ;6063 ■i 817•473-9376 ME 817.473-3483
• RELEASED SPECIFICATI&
HEWLETT PACKARD
33,320 S.F. MODULAR BUILDING
■ ■■
■ ■■ an a■
MTECH
Building Systems, Ltd.
9.3 INTERIOR WINDOWS: Windows at computer room shall be installed 4'-0" AFF to ceiling.
Glazing shall be 1 /4" clear tempered glazing. Glazing in corridor shall
be 1 /4" clear wire safety glass. Glazing shall be set in 16 ga. steel
frame.
9.4 FINISH: Interior window frames shall be painted with Sherwin-Williams #N-1-
30 B-1-1 /64 Y-3-1 Sea Beach.
9.5 SKY LIGHTS: Skylights shall be 2'x4' thermally broken dual pane, domed skylight
equal to Bristolite AST-CM-2-WT2.
10.0 ELECTRICAL
10.1 SERVICE: 120/208v - 3 phase - 4W - 60hz
10.2 LOAD CENTER: (29) 30 space and (5) 42 space 3 phase indoor flush mount with 200
AMP main breaker. (Load centers to be full of 20 AMP breakers.)
10.3 BREAKERS: All breakers shall be plug in type. (G.E. THQL 1120-HM)
10.4 ENTRANCE: Each load center shall have (3) 2" EMT conduit extending from each
load center to a 24"x24"x6" box below floor.
10.5 CROSSOVERS: J-boxes shall be installed above the ceiling for electrical crossovers.
10.6 RACEWAY/
CONDUCTORS: Minimum #12 AWG type THHN copper wire in concealed EMT conduit
with set screw fittings.
10.7 FLUORESCENT
LIGHTS: 4'-0" 120v, three tube, recessed, fluorescent light with parabolic
diffusers, T-8 lamps and motoralla electronic ballasts "Columbia:
Parabolume P-4- 243G-43363, 18-cell. Illuminance of 30 FX and
uniformity ratio not exceeding 5:1 . (Lights shall be field installed.)
10.8 INCANDESCENT
LIGHTS: Double 60 watt incandescent drum lights in janitor closet.
10.9 EXIT LIGHTS: Single faced 120 volt ceiling mount exit light with back up battery
power shall be field installed. Refer to plans for locations.
10.10 EMERGENCY LIGHTS: Dual head emergency light with back up battery power shall be field
installed. Refer to plans for locations.
10.11 RECEPTACLES: Ivory 20 AMP duplex grounding type with matching plastic cover.
HEWLETTISPE
7
Rev061995
■1400 U.S. HIGH��'.��' ?87 SOLiTH a■ MANSFIELD, TEXAS 7t,0h3 ■i 817 ■473-9376 ME 817.473-3483
RELEASED SPECIFICATil&
HEWLETT PACKARD MTECH
33,320 S.F. MODULAR BUILDING Building Systems, Ltd.
Provide J-box in floor with 120v 20 AMP service at each coffee
station.
10.12 G.F.C.I.: Restroom receptacles shall be provided with GFCI protection.
10.13 SWITCHES: Ivory 20 AMP toggle type with matching plastic cover.
10.14 CARD ACCESS: Provide (3) 4"x4" box with 1 " EMT to above ceiling with pull wire.
Final wiring and card access shall be by H-P. (Locations as shown on
drawings)
10.15 MISCELLANEOUS: Open office space shall be provided with 4"x4" junction boxes
mounted under floor for H-P supplied conduit and wiring. As per
drawings (Boxes shall be Raco #257 with cover.)
One GFCI recept under floor in restroom areas for heat trace at water
service entrance.
11.0 PLUMBING
11.1 WATERLINES: Type "L" copper with sweat copper fittings. All fixtures shall be
provided with shut-off valves.
11.2 WATTELINES: PVC-DWV-SCH-40 drain, waste and vent lines.
11.3 WATERHEATER:
(1) 6 gallon 120v electric with single watt element and T&P valve.
11.4 WATER CLOSET:
The water closets shall be white vitreous china flush valve with
elongated bowl, as manufactured by American Standard "Madera"
aquameter 1.5 GPF. Each water closet shall be provided with a
hinged open -front seat. One water closet in each restroom shall be
installed to accommodate the- handicapped. Flush valve shall be Zurn
"aquaflush" #6000 WSI YB.
11.5 PARTITIONS:
5'-0" high steel with baked on enamel finish modesty partition
installed 12" from the floor with modesty door and lock.
Color shall be Lt. Gray
11.6 URINAL:
The urinals shall be white vitreous china wall hung as manufactured
by American Standard "Allbrook" 1.0. Each urinal shall be equipped
with a Zurn aquaflush valve #Z-6003-20.
11.7 BLINDS:
A 42" high x 18" steel with baked on enamel finish shall be installed
adjacent to each urinal. Color shall be Lt. Gray.
HEWLETTISPE
8 Rev061995
■1400 U.S. HIGHWAY 287 SOUTH ■o NMANrSFIELD, TEXAS 76063 ■i S17.473-9376 "RiFAX 817.473-3483
RELEASED SPECIFICAT& � 0 ME 0: n n
AMTECH
HEWLETT PACKARD
33,320 S.F. MODULAR BUILDING Building Systems, Ltd.
11.8 LAVATORIES: Each restroom lavatory shall be Roxalyn flat slab vitreous china wall
hung with 4" washerless centerset with lever handle. One lavatory
in each restroom shall be installed so as to accommodate the
handicapped. Lavatory shall be American Standard #0195.073 White.
Faucet shall be Symmons "Temptrol" S-90-2.
11.9 MOP SINK: Single fiberglass mounted on legs with trap and laundry tray faucet.
11.10 WATER COOLER: 8 gph wall mounted water cooler Elkay #EBFSA-8.
11.11 ACCESSORIES: Toilet paper holders by H-P.
S.S. grab bars at one water closet in each restroom.
18"x36" metal edged mirror above each lavatory.
11.12 MISCELLANEOUS: Provide 1 /2" type "L" copper stubbed out of floor and with "Tee"
under floor for H-P installed coffee stations. Install adjacent to
electrical J-box.
Note: In wall blocking required for H-P provided and installed T-P
holders, paper towel holders, soap dispensers and feminine hygiene
dispensers.
12.0 H.V.A.C.
12.1 PACKAGED: Provide (22) 60,000 B.T.U. 208v 3 phase, (1) 36,000 B.T.U. 208v 3
phase, (1) 24,000 B.T.U. 208v 1 phase Marvair wall mount air
conditioners.
12.2 HEATING: 15 KW 208v electric resistance strip in each 60,000 B.T.U. air
conditioner.
9 KW 208v electric resistance strip in 36,000 B.T.U. air conditioner.
10 KW 208v electric resistance strip in 24,000 B.T.U. air conditioner.
12.3 SUPPLY DUCTS: Rigid foil faced fiberglass duct with 1 " wall thickness installed below
rafters with insulated circular flex to designated diffusers.
12.4 DIFFUSERS: 24"x24" white stamped metal with adjustable damper. (J&J model
1444 )
12.5 RETURN AIR: Return air grilles at plenum walls.
12.6 THERMOSTAT: (21) manually adjustable with cooling sub -base.
HEWLETTISPE
9
Rev061995
x1400 U.S. HIGHWAY 287 SOUTH nim MANSFIELD. TEXAS 76.063 ■i 817.473-9376 11FAX 817.473-3485
RELEASED SPECIFICATI* • �� �� '�
HEWLETT PACKARD MTECH
33,320 S.F. MODULAR BUILDING Building Systems, Ltd.
12.7 EXHAUST FANS: (4) 180 cfm ceiling mount with back draft damper wired to light
switch in each restroom.
Note: (H.P. shall be responsible for connection of H.V.A.C. units from
disconnect to electrical power source.)
13.0 CASEWORK N/A
14.0 FURNISHINGS
14.1 WET TYPE
SPRINKLER: Complete wet type sprinkler system shall be site installed with
exposed sprinkler heads designed to provide a density of 10/1500.
System based on minimum available water supply of 80 static, 69
residual, 1684 GPM flow based on 4" fire service into building.
Sprinkler heads shall be installed above and below suspended ceiling.
14.2 FIRE ALARM
SYSTEM: Site installed fire alarm system equal to simplex 400-2 series. System
shall include fire alarm control panel, manual pull stations, horns and
strobes. Heat detectors shall be provided under floor.
(Plant to install single gang boxes with EMT conduit stubbed to above
ceiling with pull wire for pull stations, horns and strobes per print.)
15.0 DESIGN CRITERIA
15.1 FLOORS: The floor system shall be constructed to accommodate a live load of
50 psf in addition to the dead loads. The floor system shall also be
capable of supporting a 2000 pound concentrated load over a 2'-6"
square area.
15.2 WALLS: The building construction and tie -down system to be designed to
resist the force created by 100 mph wind, based on the provisions of
the applicable codes for lateral forces, uplift, and overturning forces.
15.3 ROOFS: All structural components of the roof system shall be designed and
erected to span their respective areas and carry a snow load of 30 psf
and a dead load of 12 psf.
15.4 HEATING/COOLING
HEWLETTISPE
The heating/cooling system shall be designed to the requirements of
Ft. Collins.
10 Rev061995
z1400 U.S. HIGHWAY 287 SOUTH u\I?,NSFIELD. TEXAS 76063 ■i 8171 -473-93 6 as 517 ■473-3-185
r RELEASED SPECIFICATIA • �� �� ��
HEWLETT PACKARD MTECH
33,320 S.F. MODULAR BUILDING Building Systems, Ltd.
15.5 CODES: The building shall be built in accordance with the following codes.
A. Uniform Building Code - 1991
B. Uniform Plumbing Code - 1991
C. Uniform Mechanical Code - 1991
D. National Electric Code
E. Americans with Disabilities Act
F. State of Colorado Department of Housing
G. All plans will be approved and sealed by a Professional Engineer
licensed in the State of Colorado
H. State of Texas Department of Licensing & Regulation Rules
FIELD ACTIVITIES
16.1 SITE PREPARATION: No provision for site preparation shall be included. It is presumed that
the site shall be cleared, ready for construction. H-P shall be
responsible for extension of electrical and plumbing service and final
connection.
16.2 FOUNDATION Ramtech shall provide piers down each steel I-beam of building at a
maximum of 10'-0" on center. The piers shall consist of 4"x16"x16"
precast concrete base pad with 8"x8"x16" open -cell concrete blocks
placed atop. Footings at columns will consist of poured in place steel
reinforced 28"x8" concrete grade beams designed to support the roof
loads to grade. The foundation will be designed by and bear the Seal
of a Registered Professional Engineer licensed in the State of
Colorado.
16.3 ENTRY ASSEMBLIES: N/A
HEWLETi3.5PE
11
Rev061995