Loading...
HomeMy WebLinkAboutFORT COLLINS NISSAN-KIA - PDP210017 - SUBMITTAL DOCUMENTS - ROUND 2 - LETTER OF INTENTDecember 20, 2021 City of Fort Collins Development Review 281 North College Avenue Fort Collins, CO 80524 RE: Letter of Intent for Fort Collins Nissan-KIA Development Dear Development Review Coordinator: Christian Core Academy is the owner of the Crestridge Condos property (Parcels #9611127000, #9611127001, #9611127002 & #9611127003) located at 125 Crestridge St. in Fort Collins. This property abuts property owned by WWW Properties LLC that will be redeveloped with the proposed Fort Collins Nissan-KIA Development. We understand that the Fort Collins Nissan-KIA development plan shows the removal of Crestridge Street and vacation of the public right of way immediately north of the Crestridge Condos property as preliminarily shown on Exhibit A. We understand that a driveway access with an access easement will be provided by Nissan KIA in order for the Crestridge Condos property to have a second access point to Venus Avenue as preliminarily shown on Exhibit B. We will work with Fort Collins Nissan-KIA as their development submittals proceed regarding the proposed development as approximately shown on Exhibits A & B. Sincerely, Leslie Leis Christian Core Academy Board Member Attachments: Exhibit A – Fort Collins Nissan-KIA Detailed Existing Conditions and Removals Plan - South Exhibit B – Fort Collins Nissan-KIA Detailed Horizontal Control Plan - South DocuSign Envelope ID: 47883F15-CF2F-46E4-8A98-E12B7BD204CB 12/20/2021 EXISTING SIGN TO BE REMOVED EXISTING 24" IRRIGATION PIPE EXISTING HEADWALL TO BE REMOVED EXISTING FENCE TO BE REMOVED EXISTING SIGN TO BE REMOVED R.O.W. (VARIES) FL-FL (VARIES) EXISTING 14" WATER EXISTING 6" WATER TO REMAIN EXISTING 6" WATER EXISTING FENCE TO BE REMOVED EXISTING WOOD POSTS TO BE REMOVED 60' R.O.W. (TO BE VACATED) EXISTING GRAVEL PARKING AREA TO BE REMOVED 60' R.O.W. EXISTING 8" SANITARY EXISTING WETLANDS TO BE RELOCATED EXISTING 24" IRRIGATION PIPE (SEE NOTE 8) REMOVE EXISTING CURB & GUTTER SAWCUT EXISTING PAVEMENT REMOVE EXISTING CONCRETE PAN REMOVE EXISTING CURB & GUTTER SAWCUT EXISTING PAVEMENT REMOVE EXISTING CURB, GUTTER & SIDEWALK REMOVE EXISTING SIDEWALK BARRICADE EXISTING XCEL GAS TO BE LOWERED WITH GRADING (SEE NOTES 4&7) EXISTING STORM & STRUCTURE TO BE REMOVED EXISTING PRIVATE LIGHTING AND ELECTRIC TO BE REMOVED EXISTING CONCRETE WALL TO BE REMOVED COLLEGE AVE (HWY 287)VENUS AVENUEMILKY WAY DRIVE MARS DRIVEEXISTING CRESTRIDGE CONDOS BUILDING TO REMAIN #5822EXISTING#5828EXISTING#5834EXISTING#200 EXISTING #206 EXISTING #214 EXISTING #218 EXISTING #201 EXISTING#5836EXISTING#5835EXISTING#5817 EXISTING #224 EXISTING #230 EXISTING CRESTRIDGE DRIVE EXISTING BUILDING TO BE REMOVED EXISTING TREE TO BE REMOVED (TYP.) (SEE NOTE 6) EXISTING DIRT ROAD TO BE REMOVED EXISTING FLAG POLE TO BE RELOCATED EXISTING XCEL GAS TO BE LOWERED WITH GRADING (SEE NOTE 7) EXISTING ELECTRIC TO BE LOWERED AND/OR RELOCATED WITH HWY 287 WIDENING (SEE NOTE 7) REMOVE 1550 LF STRIPING REMOVE TURN ARROW (TYP) REMOVE TURN ARROW (TYP) REMOVE 343 LF STRIPING EXISTING CONTAINERS TO BE REMOVED PREPARED FOR:JOB NUMBER SHEET NUMBER SHEETSOF DATE SUBMITTED:VERTICAL: HORIZONTAL: SCALEPRELIMINARYPLANSNOT F O R C O NST R U CTI O N PROJ. MGR:DRAWING NAME:PATH:DESIGNER:DATE:TIME:The engineer preparing these plans will not be responsible for, or liable for, unauthorizedchanges to or uses of these plans. All changes to the plans must be in writing and mustbe approved by the preparer of these plans.NO.BYDATECAUTIONREVISIONS:CIVIL ENGINEERING & CONSULTING UNITED CIVIL Design Group 19 OLD TOWN SQUARE #238 FORT COLLINS, CO 80524 (970) 530-4044 www.unitedcivil.com TCC CORPORATIONFORT COLLINS NISSAN-KIA12/13/2021U21004 1" = 40' 1" = N/A 12/13/20216:07:51 PMC:\UNITED CIVIL DROPBOX\PROJECTS\U21004 - NISSAN DEALERSHIP\CADD\CP\C1.0X - DETAILED EXISTING CONDITIONS PLANS.DWGC1.0X - DETAILED EXISTING CONDITIONS PLANS####C1.02 25DETAILED EXISTING CONDITIONS ANDREMOVALS PLAN - SOUTH7 LEGEND COLLEGE AVE (HWY 287)VENUS AVENUEMILKY WAY DRIVE N KEYMAP LOT LINE PROPERTY BOUNDARY RIGHT OF WAY EASEMENT CENTERLINE EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR LIMITS OF DISTURBANCE REMOVE EXISTING CURB & GUTTER REMOVE EXISTING FENCE SAWCUT LINE REMOVE EXISTING UTILITY LINE REMOVE EXISTING ASPHALT REMOVE EXISTING BUILDING REMOVE EXISTING CONCRETE REMOVE EXISTING TREE SETBACK REMOVE EXISTING UTILITY STRUCTURE REMOVE EXISTING GRAVEL NOTES 1.EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. THE ENGINEER DOES NOT GUARANTEE THE ACCURACY OF SUCH INFORMATION. EXISTING UTILITY MAINS AND SERVICES MAY NOT BE STRAIGHT LINES OR AS INDICATED ON THESE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO VERIFY EXACT UTILITY LOCATIONS. 2.THE CONTRACTOR SHALL PROTECT ALL EXISTING FEATURES THAT ARE NOT TO BE REMOVED ADJACENT TO THE CONSTRUCTION AREA INCLUDING, BUT NOT LIMITED TO, PAVEMENT, PRIVATE FENCES, ABOVE GROUND OR UNDERGROUND UTILITIES, STRUCTURES, AND UNDERGROUND FOUNDATIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE THAT SHOULD OCCUR TO ANY ON-SITE, OFF-SITE, PUBLIC OR PRIVATE FACILITY OR FEATURE AS A RESULT OF THE CONSTRUCTION PROCESS FOR THIS PROJECT. 3.CURB, GUTTER AND SIDEWALK SHALL BE REMOVED TO THE NEAREST JOINT. 4.CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION ITEMS IMPACTING ADJACENT PROPERTIES WITH THE PROPERTY OWNERS PRIOR TO BEGINNING ANY CONSTRUCTION ACTIVITIES. 5.CONTRACTOR SHALL COORDINATE REMOVALS ASSOCIATED WITH THE EXISTING BUILDING WITH THE ARCHITECTURAL DRAWINGS. 6.COORDINATE THE REMOVAL AND/OR SALVAGING OF ALL EXISTING TREES AND OTHER PLANTINGS SHOWN ON THIS DEMOLITION PLAN WITH THE LANDSCAPE DRAWINGS. TREE REMOVAL SHALL BE BY A BUSINESS HOLDING A CURRENT CITY OF FORT COLLINS ARBORIST LICENSE AND ON THE CITY BID LIST. A FREE PERMIT MUST BE OBTAINED FROM THE CITY FORESTER BEFORE TREES ARE REMOVED. 7.CONTRACTOR SHALL COORDINATE ALL UTILITY DEMOLITION AND/OR RELOCATION ITEMS WITH THE APPROPRIATE UTILITY PROVIDER PRIOR TO BEGINNING ANY ONSITE DEMOLITION. 8.THE LOCATION OF THE EXISTING 24" IRRIGATION PIPE NORTH OF THE SOUTHERN PROPERTY LINE IS UNKNOWN. THE PIPE SHALL BE LOCATED AND REMOVED WITH THE RELOCATION OF THE IRRIGATION SYSTEM AS SHOWN ON THE UTILITY PLANS. ASPHALT MILL & OVERLAY NORTH0 40'80' SCALE: 1" = 40' 20' COLLEGE AVE (HWY 287)VENUS AVENUEMILKY WAY DRIVE MARS DRIVE#5822EXISTING#5828EXISTING#5834EXISTING#200 EXISTING #206 EXISTING #214 EXISTING #218 EXISTING #201 EXISTING#5836EXISTING#5835EXISTING#5817 EXISTING #224 EXISTING #230 EXISTING NISSAN DEALERSHIP BUILDING KIA DEALERSHIP BUILDING EXISTING CRESTRIDGE CONDOS BUILDING TO REMAIN 125 CRESTRIDGE ST. PROPOSED WALL PROPOSED DETENTION POND PROPOSED BIORETENTION POND PROPOSED LANDSCAPE WALLS (TYP.) PROPOSED DETENTION POND PROPOSED LANDSCAPE WALLS (TYP.) PROPOSED LANDSCAPE WALL (TYP.) PROPOSED LANDSCAPE WALLS (TYP.) 6.5' 50' FL-FL 5' SIDEWALK 72' R.O.W. 9' UTILITY EASEMENT 26' EAE 26' 24' EAE 17' (TYP.) 17' (TYP.)17' (TYP.) 17' (TYP.) 19' (TYP.) 17' (TYP.) 17' (TYP.) 9' (TYP.) 26' 17' (TYP.) 9' (TYP.) 17' (TYP.) 17' (TYP.) 24' 17' (TYP.) 9' (TYP.) 19' 19' 17' (TYP.) 9' (TYP.) 9' UTILITY EASEMENT 5' SIDEWALK 6' 6' 26' 24' 24' 28' 32' 8' 17' (TYP.) 9' (TYP.) 19' (TYP.) 9' (TYP.) 17' (TYP.) 9' (TYP.) 24' 9' (TYP.) 17' (TYP.) 9' (TYP.) 17' (TYP.) 26' (TYP.) 32' EAE 24' EAE 20' IRRIGATION EASEMENT 20' SANITARY EASEMENT 20' DRAINAGE EASEMENT 19' 19' 20' SANITARY EASEMENT 20' WATER EASEMENT LOT 2 BLOCK 1 TRACT A TRACT B UTILITY & DRAINAGE EASEMENT (WIDTH VARIES) 26' EAE 24' EAE 26' EAE 26' EAE PROPERTY CORNER N:1428367.71 E:3117429.97 PROPERTY CORNER N:1428195.98 E:3117369.70 PROPERTY CORNER N:1427606.05 E:3118259.48 PROPERTY CORNER N:1427602.31 E:3117965.56 PROPERTY CORNER N:1427731.38 E:3117975.83 PROPERTY CORNER N:1427731.23 E:3117964.40 PROPERTY CORNER N:1427728.82 E:3117774.42 PROPERTY CORNER N:1427724.19 E:3117409.11 20' EXISTING UTILITY EASEMENT 20' IRRIGATION EASEMENT 15' UTILITY EASEMENT 20' IRRIGATION EASEMENT LOT 1 BLOCK 2 LOT 1 BLOCK 1 PROPOSED FIRE HYDRANT (TYP.) PROPOSED WETLAND CHANNEL PROPOSED BIORETENTION POND POND OUTLET (TYP.) 100' NATURAL HABITAT BUFFER ZONE 150' RIGHT-OF-WAY LOT LINE AFTER ROW VACATION 60' UTILITY & DRAINAGE EASEMENT LOT LINE (TYP.) 7' 8' 10' 8' 7' 10' 7' 8' 10' 10' STORM INLET (TYP.) 26' 2.5' CATCH CURB 12' CONCRETE PAN 235' TRANSITION TAPER 99' FL-FL 135' TRANSITION TAPER SMOKEY DRIVE 235' TRANSITION TAPER 5' SIDEWALK ON-STREET PARKING BIKE LANE W/ 3' BUFFER BEGIN NORTHBOUND PARKING ON-STREET PARKING END SOUTHBOUND PARKING BIKE LANE 55' CL-FL 9' 13' 12' 270' TURN BAY PROPERTY CORNER N:1428035.68 E:3118260.47 SECTION LINE PROPOSED DOUBLE STACKED PARKING FOR CAR STORAGE 19' (TYP.) 9' (TYP.) 9' (TYP.)9' (TYP.) 19' (TYP.) 3' 3' BIKE LANE W/ 3' BUFFER TRANSITION BIKE LANE BUFFER LOT LINE AFTER R.O.W. VACATION (COINCIDES WITH EXISTING LOT LINE SINCE ROW WAS ENTIRELY DEDICATED BY NORTHERN PROPERTY OWNER. 24' ACCESS & EMERGENCY ACCESS EASEMENT 8' SIDEWALK PREPARED FOR:JOB NUMBER SHEET NUMBER SHEETSOF DATE SUBMITTED:VERTICAL: HORIZONTAL: SCALEPRELIMINARYPLANSNOT F O R C O NST R U CTI O N PROJ. MGR:DRAWING NAME:PATH:DESIGNER:DATE:TIME:The engineer preparing these plans will not be responsible for, or liable for, unauthorizedchanges to or uses of these plans. All changes to the plans must be in writing and mustbe approved by the preparer of these plans.NO.BYDATECAUTIONREVISIONS:CIVIL ENGINEERING & CONSULTING UNITED CIVIL Design Group 19 OLD TOWN SQUARE #238 FORT COLLINS, CO 80524 (970) 530-4044 www.unitedcivil.com TCC CORPORATIONFORT COLLINS NISSAN-KIA12/13/2021U21004 1" = 40' 1" = N/A 12/13/20216:07:20 PMC:\UNITED CIVIL DROPBOX\PROJECTS\U21004 - NISSAN DEALERSHIP\CADD\CP\C2.0X - DETAILED HORIZONTAL CONTROL PLANS.DWGC2.0X - DETAILED HORIZONTAL CONTROL PLANS####C2.02 25DETAILED HORIZONTAL CONTROL PLAN - SOUTH10 NORTH0 40'80' SCALE: 1" = 40' 20' LEGEND PROPOSED BUILDING CATCH CURB & GUTTER SIDEWALK / TRAIL FENCE EXISTING PROPERTY BOUNDARY PROPOSED PROPERTY LINE RIGHT OF WAY SECTION LINE COLLEGE AVE (HWY 287)VENUS AVENUEMILKY WAY DRIVE N KEYMAP GENERAL NOTES 1.CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION ITEMS IMPACTING ADJACENT PROPERTIES WITH THE PROPERTY OWNERS PRIOR TO BEGINNING ANY CONSTRUCTION ACTIVITIES. 2.FOR BUILDING LAYOUT REFERENCE ARCHITECTURAL PLANS. LAYOUT AND DIMENSION INFORMATION SHOWN REPRESENTS OUTSIDE FACE OF WALL AS PROVIDED BY THE ARCHITECT AND IS SHOWN FOR INFORMATION ONLY. REFER TO THE ARCHITECTURAL PLANS FOR COMPLETE GRID LINE INFORMATION. 3.ALL DIMENSIONS AND LINE AND CURVE INFORMATION ARE MEASURED TO CURB FLOW LINE OR EDGE OF PAVEMENT UNLESS OTHERWISE NOTED. 4.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 5.REFER TO GRADING PLANS AND LANDSCAPE PLANS FOR LANDSCAPE WALL DETAILS AND GRADING. 6.PUBLIC CONCRETE SIDEWALKS SHALL BE 6-INCH MINIMUM THICKNESS. PRIVATE ONSITE CONCRETE SIDEWALKS SHALL BE 4-INCH MINIMUM THICKNESS UNLESS OTHERWISE NOTED. 7.PAVING AREAS (EXCLUDING SIDEWALKS) NOT DESIGNATED AS "HEAVY DUTY" SHALL CONSIST OF "LIGHT DUTY OR PARKING" PAVEMENT. SEE THE GEOTECHNICAL REPORT AND PAVEMENT SECTION DETAILS FOR MORE INFORMATION. 8.REFER TO SHEETS C5.00 & C5.01 FOR ROADWAY PLAN & PROFILES. 9.REFER TO SHEETS C5.10 & C5.11 FOR COLLEGE AVENUE CROSS SECTIONS. UTILITY EASEMENT ACCESS EASEMENT 6'