Loading...
HomeMy WebLinkAboutGUARDIAN SELF STORAGE - FDP210018 - DOCUMENT MARKUPS - ROUND 4 - UTILITY PLANS (3)Update JR RESPONSE COMPLETED JR RESPONSE COMPLETED Add patching limits for storm drain JR RESPONSE COMPLETED Upon further review,the City requires that riprap is 12-min (d50) minimum. So please use Type M. calcs show 27.8-ft of riprap length. 27.8 ft show TCE on this plan JR RESPONSE COMPLETED JR RESPONSE COMPLETED JR RESPONSE COMPLETED label wetlands show TCE here Type M JR RESPONSE COMPLETED JR RESPONSE COMPLETED JR RESPONSE COMPLETED use type M Concrete collar may be required if joints do not seat well. See note 3 Show TCEJR RESPONSE COMPLETED JR RESPONSE COMPLETED JR RESPONSE COMPLETED JR RESPONSE COMPLETED do you know the vertical location of this existing waterline? Please add to profile 8.8 ft would like to see 10-ft (min) from center of MH to water main. JR RESPONSE COMPLETED, MANHOLE MOVED JR RESPONSE COMPLETED, WATERLINE CROSSING ADDED TO PROFILE. THE EXISTING WATERLINE DEPTH WAS ASSUMED AND A LOWERING PROPOSED. use type M JR RESPONSE COMPLETED Minimum size allowable in Fort Collins is 12- inch or Type M JR RESPONSE COMPLETED