HomeMy WebLinkAboutHOWES SIX TWO NINE - FDP210025 - SUBMITTAL DOCUMENTS - ROUND 2 - PLANSSTSTSTST ST ST ST ST STOHUOHUOHUOHUOHUOHUOHUOHUXXXXXXXXXXXGGGGG
GEEEEEEEEEEEEEETTTTTTTTTTTTTT
CSSCGCSVAULTELECEELECBRKRWVAULTELECWGGDDDSS SS SS SS SS SS SS SS SS
W W W W W W W W W
W W W W W W W W W
ST ST STSTSTSTSSSSSSSSSSSSVSSVSSVSSVWSVWSVWSVWSVWSVFFFFE E E E
EEEEEEEGGHOWES STREET
ALLEY
XXXXXA1101"A251"A3101"A451"A571"A6Drip1"A7Drip1"A8Drip1"A21SYMBOLMANUFACTURER/MODEL/DESCRIPTIONPSIHUNTER PROS-06-PRS30-CV 5` STRIP SPRAY30TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITHFACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDEDWIPER SEAL WITH UV RESISTANT MATERIAL.HUNTER PROS-06-PRS30-CV 5` RADIUS30TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITHFACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDEDWIPER SEAL WITH UV RESISTANT MATERIAL.HUNTER PROS-06-PRS30-CV 8` RADIUS30TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITHFACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDEDWIPER SEAL WITH UV RESISTANT MATERIAL.HUNTER PROS-06-PRS30-CV 10` RADIUS30TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITHFACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDEDWIPER SEAL WITH UV RESISTANT MATERIAL.HUNTER PROS-06-PRS30-CV 12` RADIUS30TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITHFACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDEDWIPER SEAL WITH UV RESISTANT MATERIAL.HUNTER PROS-06-PRS30-CV 15` RADIUS30TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITHFACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDEDWIPER SEAL WITH UV RESISTANT MATERIAL.SYMBOLMANUFACTURER/MODEL/DESCRIPTIONDRIP VALVE ASSEMBLY HUNTER ICZ-101-25: DRIP CONTROL ZONE KIT. 1" ICVGLOBE VALVE WITH 1" HY100 FILTER SYSTEM. PRESSUREREGULATION: 25PSI. FLOW RANGE: 2 GPM TO 20 GPM.150 MESH STAINLESS STEEL SCREEN.DRIP FLUSH VALVE 3/4" PVC BALL VALVESYMBOLMANUFACTURER/MODEL/DESCRIPTIONREMOTE CONTROL VALVE ASSEMBLY HUNTER ICV-G-FS: 1", 1-1/2", 2", AND 3" PLASTICELECTRIC REMOTE CONTROL VALVES, GLOBECONFIGURATION, WITH NPT THREADED INLET/OUTLET, FORCOMMERCIAL/MUNICIPAL USE. WITH FILTER SENTRY.QUICK COUPLER VALVE ASSEMBLY HUNTER HQ-5RC: VALVE WITH YELLOW RUBBER COVER,RED BRASS AND STAINLESS STEEL, WITH 1" NPT INLET,1-PIECE BODY.ISOLATION GATE VALVE ASSEMBLY MATCO-NORCA 514TX: 1/2"-4" BRASS GATE VALVE, FULLPORT, WITH SOLID WEDGE. IPS. CROSS HANDLE. SAMESIZE AS MAINLINE PIPE.MASTER VALVE ASSEMBLY BUCKNER-SUPERIOR 3100, NORMALLY OPEN BRASSMASTER VALVE THAT PROVIDES DIRTY WATERPROTECTION. SIZE TO MATCH POCREDUCED PRESSURE BACKFLOW PREVENTER FEBCO 825YA: SIZED TO MATCH POC METER SIZE.REDUCED PRESSURE BACKFLOW PREVENTER IN STRONGBOX SBBC-30AL: LOW PROFILE BACKFLOW ENCLOSURE,WITH MARINE GRADE ALUMINUM. 30"L, 30"H, 16.25"W(76.2CM L, 76.2CM H, 41.275CM W).WALL MOUNT CONTROLLER HUNTER A2C-1200-M: 12-STATION CONTROLLER IN ANOUTDOOR GRAY STEEL WALL MOUNT ENCLOSURE.INSTALL WITH WIRELESS RAIN SENSOR AND WIFICENTRALUS CARTRIDGECREATIVE SENSOR TECHNOLOGY FSI-T 1" PVC TEE TYPE FLOW SENSOR W/SOCKET ENDS, CUSTOMMOUNTING TEE AND ULTRA-LIGHTWEIGHT IMPELLER ENHANCES LOWFLOW MEASUREMENT. 2 WIRE DIGITAL OUTPUT.FLOW RANGE: .86-52 GPM.IRRIGATION LATERAL LINE: PVC CLASS 200 SDR 21 PVC CLASS 200 IRRIGATION PIPE. ONLY LATERALTRANSITION PIPE SIZES 1 1/4" AND ABOVE ARE INDICATEDON THE PLAN, WITH ALL OTHERS BEING 1" IN SIZE.PLANTING BED DRIP IRRIGATION LATERAL LINE: 3/4-INCH BLANK UVRADIATION RESISTANT POLYETHYLENE PIPE TO SINGLE OUTLETEMITTERS PER ADJACENT EMITTER CHART.IRRIGATION MAINLINE: PVC CLASS 200 SDR 21 1.25-INCH UNLESS OTHERWISE NOTED.PIPE SLEEVE: PVC SCHEDULE 40 INSTALL AS SHOWN ON DESIGN OR TWICE THE SIZE OFTHE PIPE OR WIRE RUNNING THRU IT. NO TWO PIPES ORWIRE BUNDLES SHALL SHARE THE SAME SLEEVE.AIRRIGATION_SCHEDULEINSTALLATION GENERAL NOTES1.DESIGN ASSUMES A MINIMUM DYNAMIC PRESSURE AVAILABLE FOR THEIRRIGATION SYSTEM (NOT OBTAINED) OF 80 PSI+, AT A MAXIMUM PEAK FLOW OF 10GPM AT THE 3/4-INCH POINT-OF-CONNECTION (POC). VERIFY PRESSURE AND FLOW ONSITE PRIOR TO CONSTRUCTION. CONTACT GENERAL CONTRACTOR OR OWNER'SREPRESENTATIVE IMMEDIATELY IF FLOW OR PRESSURE ARE LOWER THAN LISTED ABOVE.2.ALL MAINLINES SHALL BE INSTALLED AT LEAST 5' FROM CENTER OF TREES, WHEREPOSSIBLE. DESIGN IS SHOWN FOR CLARITY, THUS MAINLINE ROUTING IN FIELD MAYLOOK SLIGHTLY DIFFERENT THAN DEPICTED IN DRAWINGS.3.CONTRACTOR SHALL CREATE A LAMINATED CONTROLLER CHART ADHERED TO THEINSIDE OF THE CONTROLLER COVER OR A LAMINATED COLORED CONTROLLER MAP.4.CONTRACTOR SHALL BECOME FAMILIAR WITH THE SPECIFICATIONS ANDINSTALLATION DETAILS FOR THIS AND RELATED WORK PRIOR TO CONSTRUCTION. FORCLARIFICATION, CONTACT IRRIGATION DESIGNER PRIOR TO CONSTRUCTION.4.1.UPON FINAL ACCEPTANCE, CONTRACTOR SHALL TURN OVER REQUIREDADJUSTMENT KEYS INCLUDING BUT NOT LIMITED TO CONTROLLER ENCLOSURE ANDBACKFLOW ENCLOSURE KEY, LOCKING VALVE BOX KEYS, QUICK COUPLER KEYS,GATE VALVE KEY, SPRINKLER HEAD AND NOZZLE ADJUSTMENT KEYS.4.2. UPON FINAL ACCEPTANCE, CONTRACTOR SHALL TURN OVER SPARE PARTSPERTAINING TO INSTALLED SYSTEM: BACKFLOW WINTERIZATION INSERT, TWO OFEVERY HEAD AND NOZZLE (ROTOR NOZZLE TREE INCLUDED), ONE RCV DIAPHRAGM,ETC.5.COORDINATE UTILITY LOCATES OF UNDERGROUND UTILITIES PRIOR TOCONSTRUCTION ("811-CALL BEFORE YOU DIG") .6.IF DISCREPANCIES ARE NOTED IN THE FIELD BETWEEN SITE CONDITIONS ANDPROVIDED DESIGNS, CONTRACTOR SHALL NOTIFY OWNER'S REPRESENTATIVE ORGENERAL CONTRACTOR IMMEDIATELY. DO NOT PROCEED WITH THE INSTALLATION OFTHE IRRIGATION SYSTEM IF SUCH DISCREPANCIES IN THE FIELD AFFECT THE PROVIDEDDESIGN, DETAILS, OR SPECIFICATIONS.7.ALL IRRIGATION COMPONENTS (MAINLINE, WIRES, LATERAL LINES, ETC.) SHALL BEINSTALLED IN LANDSCAPED AREAS WHENEVER POSSIBLE, EVEN THOUGH SAIDIRRIGATION COMPONENTS MAY BE SHOWN OUTSIDE PLANTING AREAS FOR CLARITY.8. AVOID CONFLICTS BETWEEN THE IRRIGATION SYSTEM, PLANTING MATERIALS, ANDARCHITECTURAL FEATURES WHENEVER POSSIBLE. COORDINATE POTENTIAL RELOCATIONOF BOULDERS AND TREES IN TURF AREAS WITH LANDSCAPE ARCHITECT PRIOR TOSPRINKLER LAYOUT. IF LANDSCAPE MATERIAL CANNOT BE RELOCATED,ADDITIONALSPRINKLERS MAY BE REQUIRED.8.1.WHERE POSSIBLE, MAINTAIN 3'-5' DISTANCE FROM CENTER OF TREE TO MAINLINEAND WIRES. VALVE BOXES SHALL BE AT LEAST 3' FROM TREE CENTER. MAINLINEROUTING AND VALVE LOCATIONS ARE SHOWN FOR CLARITY AND MAY BE SHOWNWITHIN THE 3'-5' RANGE NOTED ABOVE.9. CROSS FITTINGS ARE NOT ALLOWED, ONLY STANDARD TEES AND ELBOWS.10.CONTRACTOR SHALL INSTALL NOZZLES PER PLAN, UNLESS IRRIGATED AREACHANGED IN SIZE OR PLANT MATERIAL TYPE CHANGES. IF NOZZLE CHANGES AREREQUIRED AND ARE SIGNIFICANT IN SIZE, CONTRACTOR SHALL CONTACT IRRIGATIONDESIGNER FOR APPROVAL.11.CONTRACTOR SHALL FIELD LOCATE ANY EXISTING SLEEVES ON SITE PRIOR TOCONSTRUCTION WITH THE AID OF THE GENERAL CONTRACTOR. MISSING SLEEVES SHALLBE REPORTED IMMEDIATELY. NEW SLEEVES SHOWN ON PLANS ARE REQUIRED FOR BOTHPIPING AND ELECTRICAL WIRING AT EACH HARDSCAPE CROSSING. COORDINATEINSTALLATION OF SLEEVING WITH OTHER TRADES. ANY PIPE OR WIRE WHICH PASSESBENEATH EXISTING HARDSCAPE WHERE SLEEVING WAS NOT INSTALLED WILL REQUIREHORIZONTAL BORING BY THE IRRIGATION CONTRACTOR.12.INSTALL ALL ELECTRICAL POWER TO THE IRRIGATION CONTROL SYSTEM INACCORDANCE WITH THE NATIONAL ELECTRIC CODE AND ALL APPLICABLE LOCAL ELECTRICUTILITY CODES.13.THE FOLLOWING SHOULD BE NOTED REGARDING PIPE SIZING: IF A SECTION OFUNSIZED PIPE IS LOCATED BETWEEN THE IDENTICALLY SIZED SECTIONS, THE UNSIZEDPIPE IS THE SAME NOMINAL SIZE AS THE TWO SIZED SECTIONS. THE UNSIZED PIPESHOULD NOT BE CONFUSED WITH THE DEFAULT PIPE SIZE NOTED IN THE LEGEND.13.1.MAINLINE PIPE SIZES MAY VARY THROUGHOUT PROJECT. EACH MAINLINE LEGIS SIZED TO ACCOMMODATE LARGEST VALVE ON THAT LEG. STATED SIZE IN LEGENDMAY NOT BE THE LARGEST SIZE ON PLANS.14.INSTALL THREE (3) #14 AWG CONTROL WIRES FROM CONTROLLER LOCATION TOEACH DEAD-END OF MAINLINE FOR USE AS SPARES INCASE OF CONTROL WIRE FAILURE.COIL 3 FEET OF WIRE IN VALVE BOX.15.TREES IN TURF ARE NOT IRRIGATED BY DRIP SYSTEM. DRIP LATERAL ROUTED NEARTREES IN TURF ARE NOT TO RECEIVE DRIP IRRIGATION. TREES IN NATIVE SEEDED AREASARE IRRIGATED ON DRIP SYSTEM.16.VALVES FOR NATIVE SEEDED AREAS SHALL BE ON A SEPARATE PROGRAM.17.NATIVE SEEDED AREAS ARE TO BE IRRIGATED WITH A BELOW GRADE SYSTEM BUTUTILIZED FOR ESTABLISHMENT OF SEED. SYSTEM IS NOT INTENDED TO OPERATEBEYOND ESTABLISHMENT.18.NO IRRIGATION EQUIPMENT, INCLUDING BUT NOT LIMITED TO, MAINLINE, VALVES,AND SPRINKLERS, SHALL BE INSTALLED WITHIN 3' OF NEW BUILDING FOUNDATION.SYMBOLDESCRIPTIONTHE IRRIGATION SYSTEM POINT-OF-CONNECTION (POC) SHALL BEDOWNSTREAM OF THE DOMESTIC WATER TAP AND METER AT THEAPPROXIMATE LOCATION SHOWN (REFER TO MECHANICAL PLANSFOR EXACT LOCATION). INSTALL BACKFLOW PREVENTION UNIT,MASTER VALVE ASSEMBLY, AND FLOW SENSOR AS INDICATED.VERIFY EXACT LOCATION OF POC WITH OWNER`SREPRESENTATIVE. VERIFY PRESSURE AND FLOW ON SITE PRIORTO CONSTRUCTION. CONTRACTOR TO INSTALL BACKFLOW PERNATIONAL PLUMBERS CODE AND PER LOCAL CODE. BACKFLOWSHALL BE TESTED UPON INSTALLATION AND ANNUALLYTHEREAFTER.WALL MOUNT THE IRRIGATION CONTROLLER AT THE APPROXIMATELOCATION SHOWN. COORDINATE ELECTRICAL POWER TO THECONTROLLER WITH THE OWNER`S REPRESENTATIVE. CARESHOULD BE TAKEN TO INSTALL THE IRRIGATION CONTROLLER IN ALOCATION THAT IS ACCESSIBLE FOR MAINTENANCE. FINALLOCATION TO BE APPROVED BY OWNER`S REPRESENTATIVE.CONTROLLER TO BE INSTALLED PER NATIONAL ELECTRIC CODE.12REFERENCE NOTES SCHEDULEEMITTER SCHEDULEPLANT TYPEEMITTER TYPEGPH/OUTLETN0. OF EMITTERSTOTAL FLOWGROUNDCOVERSINGLE OUTLET 1 GPH11 GPHPERENNIALSSINGLE OUTLET 1 GPH11 GPH1 GAL. SHRUBSINGLE OUTLET 1 GPH11 GPH5 GAL. SHRUBSINGLE OUTLET 1 GPH22 GPHTREE IN SHRUB BEDSINGLE OUTLET 1 GPH4-84-8 GPHNOTES:1.MULTIPLE OUTLET EMITTERS CAN BE UTILIZED IN DENSELY PLANTED AREAS AND FOR TREES IN SHRUBBEDS.NORTHIR1.1P.O. BOX 369
Ault, CO 80610
970.402.3047
Michelle@MPiDesignsllc.com
MPi Designs
IR1.2P.O. BOX 369
Ault, CO 80610
970.402.3047
Michelle@MPiDesignsllc.com
MPi DesignsMASTER VALVEASSEMBLY2ISOLATION GATE VALVE ASSEMBLY4QUICK COUPLING VALVEASSEMBLY5REMOTE CONTROL TURFVALVE ASSEMBLY6REMOTE CONTROL DRIPVALVE ASSEMBLY86-INCH POP-UP SPRAYSPRINKLER ASSEMBLY7SINGLE OUTLET EMITTERASSEMBLY9TYPICAL TRENCHINGDETAIL12DRIP FLUSH CAPASSEMBLY10WALL MOUNT CONTROLLERASSEMBLY11FLOW SENSORASSEMBLY3BACKFLOW PREVENTION UNIT1