HomeMy WebLinkAboutHORSETOOTH BUSINESS PARK - AMENDED MASTER PLAN - 78-88A - SUBMITTAL DOCUMENTS - ROUND 1 - GEOTECHNICAL (SOILS) REPORT• 0
REPORT
OF A
GEOTECIMICAL INVESTIGATION
FOR
PAVEMENT DESIGN
COLLINS BUSINESS PARK
�'lD�sE7aoirl
,B vs/"VEss PRRK
COLLINS PARK VENTURE
DENVER, COLORADO
PRUJLCT NO. 4703-82
WA
EMPIRE" LABORATORIES, INC.
214 NORTH HOWES STREET
FORT COLLINS, COLORADO 80521
•
0
TAF31_E: of CONTENTS
Table of Contents ........................... 6.................. I
Letter of Transmittal .......................................... ll
Report ................................................... 0.. 0. 0 1
Appendix A . . . . . ... ...... . ... . .... . .. ... ..... .. . .. .. .. . .... . . . . A-1
Test Boring Locatiun Plan .................................... A-2
Key to Borings..................................0............ A-3
Log of Borings ............................................... A-4
Appendix B.....................................0.4............ E3-►
liveein Stabllometer Results .................................. E3-2
Summary of
Test
Results .....................................
13-3
Appendix C....................................................
C-1
Empire LabOatories, Inc.
MATERIALS AND FOUNDATION ENGINEERS
214 No. Howes Fort Collins, Colorado 80522
P.U. Box 429 (303) 484.0359
March 30, 1982
Collins Park Venture
1660 South Albion Street
Dcnver, Colorado 80222
Attention: Mr. Phil Christensen
Gentlemen:
We are pleased to submit our Report of a
prepared for the streets In Collins Business
Purt Collins, Colorado.
. Branch Offices
1242 Bramwood Place
Longmont, Colorado 80501
P.O. Box 1135
1303) 776 3921
3151 Nation Way
Cheyenne, Wyoming 82001
P.O. Box 10076
(307) 632 9224
Geotechnlcal Investigation
Park located in southeast
Based upon our findings In the subsurface, we feel that tho site Is
sultable for the proposed roadway construction, providing the design
criteria and recommendations set forth In this report are met. The
accompanying report presents our findings In the subsurface and our
recomn►clld3tions based upon these findings,
Very truly yours,
EMPIRE l_A[301tAT0 ES, It
P e I R. Shurrud
Sertlor Engineering Geologist
Reviewed by:
,
` t �
Chester C. Smith, P.E.
President
clC
cc:: James H. Stewart and Associates, 111c.
MEMBER OF CONSULTING ENGINEERS COUNCIL
REPORT
OF A
GEOTECHNICAL INVESTIGATION
SCOPE
This report presents the results of a geotechnicai evaluation
prepared for the design of the proposed streets In Collins Business
Park, located at the southwest corner of Horsetooth and Timberline
I%'c,ads in southeast Fort Collins, Colorado. The scope of the project
included trst brings and laboratory testing of samples obtained fror:i
these horinils.
The objectives of this study were to (1) determine they soil and
groundviz,tor conditions at the site, (2) determine criteria for paverilerit
dci,lyn, and (3) make recommendations regarding tho proposed street
impruvcments, pavernent types, and thicknesses kit the site.
SITE EXPLORATION
The field exploration, carried out on March 16, 1982, consisted of
drilling, logging, and sampling five (5) test borings. The locations of
the test borings are shown on the Test Boring Location Plan Included in
Appendix A of this report. Boring logs prepared from the field logs are
shovin in Appendix A. These logs show soils encountered, location of
sampling, and groundwater at the time of the exploration.
The borings were Advanced with a four -inch diameter, continuous -
type, puwcr-flight auger drill. During the drilling operations, a
gE()technical engineer from Empire Lriboratorles, Inc. was present and
made continuous observations of the soils encountered.
0 0
SITE LOCATION A14D DESCRIPTION
The property Is located at the southwest corner of 11orsetooth and
Tiaibe:rline Toads In southeast Fort Collins, Colorado. More particularly,
the site is described as Collins Business Park, First Filing, situate in
the northeast 114 of Section 31. Township 7 North, Range 68 West of the
Sixth P.M., Lariner County, Colorado.
The site consists of fallow farm land bordered on the north by
Ijursetuoth road, on the east by Timberline Road, and on the %vest by
the Union Pscific railroad. The property currently is sparsely vegetated
with grass and weeds. The tract is relatively flat and has minor
drainage to the east.
LA801-ZATORY TESTS AND EVALUATION
Samples obtained from the test
borings were subjected to testing in
th:: 16horatory to provide a sound
basis for
evaluating the
physical
properties of the soils encountered.
Moisture
contents, dry
unit weights,
and the Atterberg Ilinits were determined.
A summary of
the test
results is Included In Appendix B.
Hveem stabilometer
tests
were run
to d0crailne "R" values, and curves showing
these data are
Included In
Appendix 11.
SOIL ACID GROUNDWATER CONDITIONS
The: soil proflica at the site consists of strata of materials ar-
ranged in diffe:reot caribinations. In order of Increasing depths, they
are as follows:
(1) Silt rL Topsoll: A six (6) to twelve (12) inch layer of silty
to psoll was encountered in Borings 1, 3, and 5 at the surface.
The upper sb. (6) inches of the topsoil has been penetrated
by root growth and organic matter and should not be used for
roadway $Ubgrade or as embankment inaterial.
0 •
(1) Fill Haterial: A six (6) Inch layer of fill material was
encountered at the surface of Boring 4 and consists of a
heterogeneous mixture of slit, sand, and gravel. Six (6)
Inches of gravel base and/or subbase material was encountered
tit thr surface of boring 2.
(3) Sandy Silty Clair; This stratum underlies the topsoil and fill
and extends to the depths explored. The silty clay is plastic
and contains varying amounts of sand. It varies from a brown
slightly sandy silty clay to a tan to red sandy silty clay
containing traces of gravel. In general, the cljy stratus► is
moderately plastic and Is damp to molst in Its natural in situ
condition.
(4) Groundwater: At the time of the Investigation, free
groundwater was encountered In Boring 5 at o depth of sever►
(7) feet below the surface. No free groundwater was
encountered In the remaining test borings to depths eight (8 )
feet below the surface. iliater levels in this area may be
sut)ject to change due to seasonal variations and irrigation
demands on and/or adjacent to the: site.
RE:COlAHENDATIONS AND DISCUSSiON
It Is our understanding that East Ilorsetooth lZoad is to be vilder►ed,
Timberline ko:,d Is to be Improved and reconstructed, and local
corninercial streets will ba built within the proposed Collins Business
Pork. binied on profiles provided to us by James Il. Stewart arid
Astiociates, Inc., maximum cut:, arid fills of less than two (2) feet are
proprised fur all streets within the business park.
Eloth rigid ai►d flexible pavement sections have been evaluated for
the hrupusad structs at the site. The street design is based on the City
of Fort Collins "Desicin Criteria and Standards for Streets," dated
September 1961. E lghtcen (18) kip equivalent daily load applicaations for
liursetouth and Timberline Roads wera provided by James 11. Stewart and
-3-
r
Associates, Inc., and elghteen (18) kip equivalent dally load applications
for the local commercial streets %vk:rc assumed by Empire Laboratories,
Inc. The City of Fort Collins "Desiin Criteria and Standards for
Streets," a projected eighteen (18) kip e(Itilvalent dally load application
of fifty (50) for Cast Horsetooth and Timberline Roads and twenty (20)
for thu local commercial streets, and an "KII value of 15 determined from
Ilvuem stahlkimeter tests correlated with a "K" value of one hundred
tvicitty (120) pounds per square Inch per inch were utilized for the;
Pavi..'aw►t dosl�n.
Site: Gradin_ea
It Is re:coinrne nclod that the upper six (6) Inches of topsoil below
prohused streets be stripped and stockpiled for reuse In planted areas.
The existing asphalt along Timberline Road should also be removed and
wasted off the sit(,. The upper six (6) Inches of the natural subgrade
or e;clstii19 gravel base which may be utilized as sui;grade should be
;carifled and rccompacted at or wet of optimum molsturc to at least
ninety-five percent (95%) of Standard Proctor Density ASTM D 698-78.
(Sce Appendix C.)
All fill should consist of on -site soils or Imported material having an
"f2" value of 15 or greater and approved by the geotechnic► l engineer.
Tlw fill should bc: placed In uniform six (6) to eight (8) Inch lifts and
cu1,1pactcd at or wet of optimum moisture to at least ninety-five percent
(95%) of Standard Proctor Density ASTM D 698-78. Finished subgrade: In
cut sections should be scarified a miniriium of six (6) inches and
recompactred jt or wet of optimum moisture to at icast ninety-five percent
(95%) of SL.-r►darel Proctor Density ASTM D 698-78. Cut and fill slopes
should be placed on grades no steeper than 2:1.
Each succc;,slvL: lift of fill placed on embankinent slopes should be
benched ,lightly hito the existing grado. All street subgr;ide shnuid b:2
plt.cecJ a viiiiiuuirn of three (3) fact above existingg groundwater
elevations, it Is recommended that all stripping, sribgrade preparation,
and till plzcc;ment be inspected by the cgeotechnical engineer. Field
eiunsity tt;sts should b:j taken in the compacted subgrade and fill under
0 •
the supervision of the gcotechnical engineer to ensure proper
compaction.
Flexible Pavement
It is our opli-don that flexible pavernent Is a sultitble alternate for
roadway construction at the site. The flexible pavement alternate at the
site should consist of asphaltic concrete underlain by crushod aggregate
base course or asphaltic concrete undr-rlaln by plant mix bituminous
bjse course. Using the City of Fort Collins "Design Criteria and
Standards for Streets," a serviceabliity Index of 2.5, a regional factor of
0.75, an "R" valuo of 15, a twenty (20) year design life, an eighteen
(18) kip equivalent cially load application of fifty (50) for Ilorsetooth and
Timberlines Roads and twenty (20) for local commercial streets, and
we lghtud structural nurabcrs of 2.85 for Ilorsetooth and Timberline Roads
and 2.50 for local comrnerclal streets, the following pavement thicknesses
are recommended:
linrsetooth and Timberline Roads
Aspi►ultic Concrete 4"
Crushed Aggregate Base Course: 9"
Total Pavement Thickness 13"
Asphaltic Concrete 3"
Nla,,,t tii;c i.situminous Haso Course 41"
T-t.:l rlay.�ment Thickness 71"
Local Commercial Streets
A sph.,ltic Concrete 3"
Crushed t,g(jregzt,e (lase Cours#i 10"
Total Pavement Thickness 13"
-5-
Asphaltic Concrete 2"
Plant Wx Biturninous Cease Course 31"
Total Pavement Thickness 5l"
Thy crushed aggregate base course should racet City of Fort Collins
Class 6 The subgrade helow the proposed asphalt
paver:lent should be prepared in accordance vrlth the; recommendations
dlsr eased In the "Site Criding" scalon of this repurt. Upon proper
prep.iration of the subgrada, the base course should be: placed and
compacted at optirium raolsture to at least ninety-eight percent (98%) of
Stzridard Proctor Density ASTI.t D 698-78. (Sea Appendix C. )
It Is recommended that the asphaltic eoneretc. and/or plant nix
1)ItUl.fli,ous base bu placed in two (2) to three (3) Inch lifts. All plant
taix ba!;u course and asphaltic concrete should meet City of Fort Collins
specifications and should he placed in accordance with these
spe:cificatioies. All base course material should have a minimum "R" value
of 78, the pl;5r,t mix bituminous base should have an Rt value of 90 or
greater and the asphaltic concrete should have: an Rt value of 95 or
grsate:r. Fleld cicrtsity te;;;ts should be taken in the ;aggregate base,
bituminous base, and asphalt undf,r the direction of the geotechnical
e;nclint,:r.
fiend Pavement
A foasible foundaticin alternate at the site would be rigid pavement.
using the elghteen (18) kip equivalent daily load applications described
ijt,ove, a mudulus of subgrade reaction of one hundred twenty (120)
I-jounds per-equ.iro Inch per inch Lased on an "R" value of 15, a design
life of tw..rity (20) years, and a concrete design with a modulus of
rupture z f five hundred fifty (550) pounds per sriusre inch, the
fullOwing pav,;ric�nt thicknesses are recomme:nclud:
_llursetooth and Timberline koad•;
Ptcnreinforeed Concrete - 51"
-6-
E
t call Corarierclal Streets
tionreinfurcod Concrete - 41"
It is recommended that bll existing asphalt along Timberline fload be
rcr.ioved. The suhdrade below propcsod roadways should be prepared in
ac:c:irdonce with the recormendations discussed in tho "Site: Grading"
suction of this report. The concrete pay. meat should be planed directly
on the subgrada that has been uniformly and properly prepared in
accrirdanco with the above recommendations. All concrete used In the
pavc.r.tant Shall meet ASTiA specifications, and all aggregnte shall conform
to ASTM, C-33 specifications. The concrete should be designed with a
mililmum modulus of rupture of five hundred fifty (550) pounds per
square inch In twenty-eight (28) days. It is recommended that
laboratory mix designs be cinno to determine the proper proportions of
aggregate, cement, and water necessary to meet the roquirements. It is
essential thvt the concrete have a low water -cement ratio, an adequate:
cement factor, and sufficient quantities of entrained air. Joints should
be carefully designod and constructed in accordance with the City of
Fart Collins "Design Criteria and Standards for Streets" to insure good
perform,ince of the pavemant.
It Is r,?eoimmurided th;ct all eoncrctta pavement. be: placed Iri
accordance with City of Fort Collins specifications. if paving Is done
during cold weather, acceptable cold weather procedures as outlined in
the City specifications should he utilized. Tho concrete pavement should
be properly cured and protected In accordance with the above:
shr:clfic..tions. Concrota injur_,d by frost should be reimuved and
replaced. It is recommended that the pavem?nt not be opened to traffic
ut+tll a flexible strength of five hundred fifty (550) pounds Per square;
inch Is nbtalr,cd ix ,i inliOrnimn of fourtac:n (14) (Jays after the concrete
his b+:,n
GENERAL COMMENTS
This rcDort has bean prepared to old In the evaluation of the
propt'.M! find to the engincer in the d-:sigri of this project. In
-7-
• 6
the event that any changes In the design of the pavement structure are
planned, the conclusions and recommendations contained in this report
Will Trot he considered valid unless sald changes are reviewed arid
conclusions cf this report modified or :approved in writing by Empire
1_.rhoriAorle!i, Inc., the gootechnlcal eroglnerrr of record.
Every effort was made to provide comprehensive sitc, coverige
throu(.11) c.rref►rl 1,)c3tirns of the test borings, while Iceoping the site
Investir;ition econc,micaily feasible. Variations In soil and groundwater
cot,Altlons between test borings may be Encc►untered during construction.
In order to purmlt correlation between the roported subsurface rondltions
anti the actur.l conditlons encountered daring crnstruction and to aid In
carrying out the plane and spcclfications as originally contemplated, It
Is recomme-ndod that Entire Lahorotorles, Inc, be retained to perform
coittl►,tiotis co ,►traction revlcw during the excavation and foundation
phi�sc s of the wc,rk. Empire Laboratories, Inc, a ,sumes no responsibility
for compliance with the; rcconriend3tions Ineludcd in this report unless
they/ have been rosined to perform adequate on -site construction review
durin(i the course of constructir,n.
-8-
APPENDIX A.
I
TEST BORING LOCATION PLAN
GoLUrls bdsi�[.x rAfK
.f�4T DAr,
1 t
t ,jke-,4L ✓n,r
31 -7- 68
A-2
I
KEY TO BORING LOGS
TOPSOIL
•••�`
GRAVEL
®
FILL
SAND & GRAVEL
SILT
El
SILTY SAND & GRAVEL
/1
CLAYEY SILT
r3--:9
• oA
v v
COBBLES
i�
SANDY SILT
�.o�
SAND, GRAVEL & COBBLES
®
CLAY
M
WEATHERED BEDROCK
i
SILTY CLAY
SILTSTONE BEDROCK
SANDY CLAY
®
CLAYSTONE BEDROCK
ElSAND
El
SANDSTONE BEDROCK
SILTY SAND
®
LIMESTONE
CLAYEY SAND
x
GRANITE
V I LILASANDY
SILTY
CLAY F
'
SHELBY TUBE SAMPLE
STANDARD PENETRATION DRIVE SAMPLER
WATER TABLE
7 Days AFTER DRILLING
C
HOLE CAVED
5/12 Indicates
that 5 blows
of a 140 pound hammer falling
30 inches was required to penetrate 12 inches.
A-3
0 0
LOG OF BORINGS
10
15
omm
!FAA:
WA
•®
Nor
NAM
A-4
EMPIRE LABORATORIES, INC.
• 0
m--
10
LOG OF BORINGS
ter,
EMPIRE LABORATORIES, INC.
APPENDIX B.
-I F- J-
E f P E '15 11 L- P-5.
W L r) L I I'll S V EJ- I T U RE
---
I -! , , I '. .-. r t -2: C! u I, L I " , . I r! '.. i I , - - - - - . -- - - - - - I -,, . .-!
I . CJ,'. 'F I L!
B-2
C ,
O C
N
rN-
•N
C\j
N
C\j
N
. N
C\j
m [d
a
00
O
r
C71
r
r
%.D
O
r
Cn
LO
ct
S U
2
m =
Q
C
O0
v D
k-0
M
r
c
r
� j
�L
lD
lD
lD
lD
U Q
U Q
U Q
U Q
U Q
a x
d
N
LO
co
m
N
1�
r
Z' x
O
ct
r
00
(+M
U
oQ
co
r
LO
to
�T
N
p E_
r
r
r
r
r
O
CO
M
O
v
E ae
r�
M
in
CM
Irn
CM
M
M
J J—
J
N
W
�
=
a
h-
Lu
I-
LL
m m
O
_
}
N(_
Q
d
c�
C
LL
m N
a
d
r
yC LL
a
.°a
oN—
U
LL
CM
1�
r
p y a.
O
M
N
lD
r
p '
CO
CC)
O
r
O
r
O
r
O
f—
M
O
4c1
00
I.n
In
lD
M
N
r
N Ln
C7l
O
lD
N
N
00
O
dr
r
r
� f
00 M
lD
r
r
N
r
r
r
r
r
r
r
r N
N
t_
O
O
O
O
O
O
O
O
O
O
O
O O
O
m ti
N
M
00
N
M,
00
N
M
00
N
M
N M
C�
p—
I
I
I
I
I
1
I
I
1
1
I
1 1
I
O
O
O
O
O
O
O
O
.
O
.
O
.
O
O O
.
O
.
.
r
.
N
.
r�
.
r
.
N
.
I—
.
r
N
r�
.
.
c
O
OZ
r
N
M
Ct
LO
m
N
oU O
O
r�
LM
Ln
00
r
_J
Ln r
LD
r
cf'
cf
r
U
LD
M
N
r
CO
r
1
d
(S O
('M
Ui
co
M
L1 i
CO
J
r
r�
r
L1
CM
r
U
LD
M
N
r
lD
I
Q
O
N
(2) M
co
r-
r
LD
N
r
I
J
M O
Ll7
O
Ll
M
N
U
LD
>-
(M
N
r
DO
r
l
(Y
r
d
Lori
C!3
LLJ
m
^
L1'
(2) O
O
LD
K:r
LD
ct
(M
LU
J
M
r
r
M
U
LD
M
N
r
117
1
d
Q
O
_
(21 M
Co
00
O
1-,
ct
LD
1
J
r
L-�
L71
00
N
LD
U
LD
•
M
r
r
Ll'J
1
r
Q
X
111
O
Z
F-
Z
O
O
m
r-1
N
X
F-
O
r
LLJ
Q
ED
O
U
F-
Z F-
J
/--1
Z
Z
F+
d
U
U
LL
LM
S
CD LLJ
in
1
Ln
1-�
W
Z
► +
F-
F-
Ln
a
(n
..
N
�--1
Ln
Ln
Q
n
Ln
L.L
tY cz
O
d
d
d
O
d
Q
I-y
J
J
LY
J
Z
m
J
d
d
o
CD
U
�
d
APPENDIX C.
noornmry r
Suggested Specifications for Placement of Compacted Earth Fill
and/or Backfills.
GENERAL
A soils engineer shall be on -site to provide continuous observation
during filling and grading operations and shall be the owner's repre-
sentative to inspect placement of all compacted fill and/or backfill on
the project. The soils engineer shall approve all earth materials prior
to their use, the methods of placing, and the degree of compaction
obtained.
MATERIALS
Soils used for all compacted fill and backfill shall be approved by the
soils engineer prior to their use. The upper two (2) feet of compacted
earth backfill placed adjacent to exterior foundation walls shall be an
impervious, nonexpansive material. No material, including rock, having
a maximum dimension greater than six inches shall be placed in any fill.
Any fill containing rock should be carefully mixed to avoid nesting and
creation of voids. In no case shall frozen material be used as a fill
and/or backfill material.
PREPARATION OF SUBGRADE
All topsoil, vegetation (including trees and brush), timber, debris,
rubbish, and other unsuitable material shall be removed to a depth
satisfactory to the soils engineer and disposed of by suitable means
before beginning preparation of the subgrade. The subgrade surface of
the area to be filled shall be scarified a minimum depth of s.ix inches,
moistened as necessary, and compacted in a manner specified below for
the subsequent layers of fill. Fill shall not be placed on frozen or
muddy ground.
PLACING FILL
No sod, brush, frozen or thawing material, or other unsuitable material
shall be placed in the fill, and no fill shall be placed during unfavorable
weather conditions. All clods shall be broken into small pieces, and
distribution of material in the fill shall be such as to preclude the
formation of lenses of material differing from the surrounding material.
The materials shall be delivered to and spread on the fill surface in a
manner which will result in a uniformly compacted fill. Each layer
shall be thoroughly blade mixed during spreading to insure uniformity of
material and moisture in each layer. Prior to compacting, each layer
shall have a maximum thickness of eight inches, and its upper surface
shall be approximately horizontal. Each successive 6" to 8" lift of
fill being placed on slopes or hillsides should be benched into the
existing slopes, providing good bond between the fill and existing
ground.
MOISTURE CONTROL
While being compacted, the fill material in each layer shall as nearly
as practical contain the amount of moisture required for optimum compaction
or as specified, and the moisture shall be uniform throughout the fill.
The contractor may be required to add necessary moisture to the fill
material and to uniformly mix the water with the fill material if, in
the opinion of the soils engineer, it is not possible to obtain uniform
moisture content by adding water on the fill surface. If, in the opinion
of the soils engineer, the material proposed for use in the compacted
fill is too wet to permit adequate compaction, it shall be dried in an
acceptable manner prior to placement and compaction.
COMPACTION
When an acceptable, uniform moisture content is obtained, each layer
shall be compacted by a method acceptable to the soils engineer and as
specified in the foregoing report as determined by applicable standards.
Compaction shall be performed by rolling with approved tamping rollers,
It
pneumatic -tired rollers, three -wheel power rollers, vibratory compactors,
or other approved equipment well -suited to the soil being compacted. If
a sheepfoot roller is used, it shall be provided with cleaner bars
attached in a manner which will prevent the accumulation of material
between the tamper feet. The rollers should be designed so that effective
weight can be increased.
MOISTURE -DENSITY DETERMINATION
Samples of representative fill materials to be placed shall be furnished
by the contractor to the soils engineer for determination of maximum
density and optimum moisture or percent of Relative Density for these
materials. Tests for this determination will be made using methods
conforming to requirements of ASTM D 698, ASTM D 1557, or ASTM D 2049.
Copies of the results of these tests will be furnished to the owner, the
project engineer, and the contractor. These test results shall be the
basis of control for all compaction effort.
DENSITY TESTS
The density and moisture content of each layer of compacted fill will be
determined by the soils engineer in accordance with ASTM D 1556, ASTM D
2167, or ASTM D 2922. Any material found not to comply with the minimum
specified density shall be recompacted until the required density is
obtained. Sufficient density tests shall be made and submitted to
support the soils engineer's recommendations. The results of density
tests will also be furnished to the owner, the project engineer, and the
contractor by the soils engineer.