HomeMy WebLinkAboutGUARDIAN SELF STORAGE - FDP210018 - DOCUMENT MARKUPS - ROUND 3 - UTILITY PLANS (5)Reinforced to support 40-tons JR Response: Addressed. provide riprap spec and placement detail Please provide a detailed grading plan for this area. Forebay See detail sheet 15 Yellow =Private Storm Green = public This color shading is just for reference.Please label Public or Private on the profile sheets. JR Response: Addressed. JR Response: Addressed. Provide geogrid detail and product in the plans. (see reinforced turf from Lincoln Street project as example) Provide detail and spec for riprap Please concrete collar connection to existing pipe. Provide detail for this connection. add bar grate on outlet structure. Please do not bolt MH covers. water pressure (HGL) should be relieved by type R inlets pipe size? Public Storm PrivateStorm See detail (sheet xx)and headwall profile this page JR Response: Addressed. JR Response: Addressed. JR Response: Addressed. JR Response: Addressed. JR Response: Addressed. JR Response: Addressed. JR Response: Addressed. 100-yr HGL is out of ground. Please revise. Please up-size pipe to 18-inch pipe or twin 15-inch pipes. Public StormPrivate Storm Private Storm JR Response: Addressed, upsized to twin 15in JR Response: Addressed. JR Response: Addressed. Public Storm JR Response: Addressed. Public Storm JR Response: Addressed. what is height of baffle block? See detail this sheet Show where foundation drain connects Private Storm Private Storm JR Response: Addressed. JR Response: Addressed. JR Response: Addressed. JR Response: Addressed. JR Response: Addressed, height added A spec for the Sand media needs to be called out on the plans. CoFC defers to MHFD spec for sand filters. JR Response: Addressed. Still curious why this is benched? JR Response: it is benched for the sidewalk to go over the top. Where is underdrain pipe? Top of structure should be below asphalt depth. Response: Addressed. Response: Addressed.