HomeMy WebLinkAboutGUARDIAN SELF STORAGE - FDP210018 - DOCUMENT MARKUPS - ROUND 3 - UTILITY PLANS (2)CALLOUT SIZE AND
MATERIAL OF
EXISTING WATER
LINE (8" PVC)
REMOVE ALL
THRUST BLOCK
SYMBOLS
This line-type doesn't
match Ex. Water
Main
This valve is on the
6" PVC line heading
north.
Ex. 14" DI Water
Main
Show the Ex. 8" PVC
Water Main
Ex. 12" PVC Water
Main
FH and 6" fire line
need to be within
easement.
JR Response: Addressed
JR Response: Addressed
JR Response: Addressed
JR Response: FH and 6"
line are within utility ease-
ment outlined in red.
JR Response: Addressed
JR Response: Addressed
JR Response: Addressed
Show Ex. 12" PVC
WL.
Contact FCLWD if
you need linework.
Show 12" WL in
profile view.
"SS" means Sanitary
Sewer. Please
rename Storm MHs -
Typ.
We want to see 1.5'
of clearance. If not
possible, the crossing
needs to be mitigated
in some way.
JR Response: Addressed
JR Response: Addressed
JR Response: Addressed
JR Response: Addressed,
storm pipe adjusted to pro-
vide clearance
DELETE DETAIL.
ALL FITTINGS TO
BE MECHANICALLY
RESTRAINED.
JR Response: Addressed