Loading...
HomeMy WebLinkAboutFOOTHILLS UNITARIAN CHURCH EXPANSION - FDP210027 - SUBMITTAL DOCUMENTS - ROUND 1 - SUPPORTING DOCUMENTATION (3) 735 South Xenon Court Suite 201 • Lakewood, CO 80228 Phone: (303) 716-1270 • Fax: (303) 716-1272 • www.givenandassociates.com 11 12, 2021 Matt Simpson Water-Wastewater Engineering RE: Water Sizing Justification Letter Project: Foothills Unitarian expansion Dear Matt, This letter is to provide justification of the existing 1-1/2” water service & meter. Our calculation for maximum flow shows 55 GPM per the calculation provided in 2018 IPC Appendix E. We calculated yearly totals by using the LEED indoor water use reduction calculator. Calculating a gallon per day valve based on services & events that are held thought the week. Services on Sunday with a total of 400 attendees and daily events hosting 90 attendees. These daily totals were added to create a weekly profile and multiplied by 52 to create a total of 38,844 Gallons per year. Our continuous flow total was calculated by providing a diversity factor to show no more than 70% of fixtures running at one. This comes out to a continuous flow of 38.5 GPM Sincerely, Jeff Given, P.E. Given and Associates