Loading...
HomeMy WebLinkAbout403 S WHITCOMB PUD - FINAL - 86-88 - REPORTS - MEMO / P & Z BOARDDevelenent Services . Planning Dlpartmenc Citv of Fort Collins NIEAIORANDUM TO: Planning and Zoning Board FROM: Sherry Albertson -Clark, Senior City Planner DATE: January 5, 1989 RE: 403 S. Whitcomb PUD Several recent developments in the application for 403 S. Whitcomb PUD have occurred and I wanted to inform you of these changes. The applicant has submitted calculations to substantiate receiving energy conservation points for Point Chart E "Business Service Uses" (see attached); is providing two additional parking spaces for his own parking use and is proposing several restrictions on the proposed PUD to mitigate impact on the neighborhood. Point Chart E: Based on a review of the energy calculations with Felix Lee of the Permits and Inspections Division, the proposed addition would exceed the minimum requirements of the model energy code for non-residential buildings and could provide an average savings of 60%. Energy savings are obtained through the use of increased insulation and energy -efficient construction materials and through minimizing the amount of glazing in the addition. On this basis, staff is awarding the applicant four points on Point Chart E. This addition provides a total of 50% on Point Chart E, which meets the minimum requirement for this chart. Thus, Criteria #2 of the Business Service Use category is satisfied. Parking: The applicant is proposing to provide two additional parking spaces at the west edge of the property, along Magnolia Street, for the use of his own vehicles. This parking, along with the proposed three spaces in front of the proposed addition, would provide adequate parking for the project. The Magnolia spaces and driveway cut would be required to be designed to City standards. The existing fence in this location would be relocated, being placed along the front and western sides of the proposed spaces. This would provide some screening of these spaces from the adjacent property to the west. 300 LaPorte Avenue • P.O. Box 580 • Fort Collins, CO 80522-0580 • (303) 221-6750 Page 2 Proposed Business Restrictions: Staff has met with the applicant to discuss ways of further reducing the potential impacts of this project on the neighborhood. As a result, the applicant has proposed the following items as ways of further mitigating any impacts on the neighborhood that could result from the introduction of a commercial use into a residential area: 1. The retail use would be conducted solely by the inhabitants of the residential building and limited to one other employee. 2. The retail use would be limited to the proposed 528 square foot addition. 3. No exterior storage of material or equipment used for the retail use would be permitted. The reasons for the staff recommendation for denial of this project were originally based on the project's failure to meet the required points on Point Chart E; failure to meet Criteria #5 of the LDGS, which requires compliance with the Comprehensive Plan; and the project's failure to satisfy Criteria #35 regarding adequate parking. The applicant has now adequately addressed the Point Chart and the parking issues. In addition, the applicant has proposed business restrictions to provide further mitigation of the impacts of the proposed commercial use. While staff believes that these business restrictions do mitigate the potential impacts of the proposed project, the issue of introduction of a commercial use into a residential area still exists. Therefore, staff is still recommending denial of this proposal on the basis that the project fails to meet Criteria #5 of the LDGS, which states "Is the development in accordance with the adopted elements of the Comprehensive Plan, including but not limited to: Master Street Plan and other adopted street policies; Open Space Plan and other adopted open space policies?" I i 3 5. f 'E I I t BUSINESS SERVICE USES For All Critera POINT CHART E Applicable Criteria Only \I 1 I II in iv Circle Criterion ;Is The Cri ericn The Correct Po;nts c�XlMUM c b e l rcpliccble Score Multiplier Eerned Feints 's No Yes �/W* No 1,01 a, Transit route X 2 0 2 -- --- b. S. College corridor X X10 0 4 g C. Part of center X X 20 3 6 d, Two acres or more X X 2® 3 0 6 e. Mixed -use i X X 2 3 6 f. Joint parking i �( 1 2 0 3 — --- 3 g, Energy conservation X- _ 2 0 4 8 f h. Contiguity X X 0 5 �0 10 i. Historic preservation y - �( 1 2 0 2 J. 1 2 0 k• 1 2 0 I. 111210- \AN — Very Well Done Totals v vl i Percentage Earned of Maximum Applicable Points VNI =V11 50% vu —24—