Loading...
HomeMy WebLinkAboutHOWES SIX TWO NINE - FDP210025 - SUBMITTAL DOCUMENTS - ROUND 1 - SUPPLEMENTAL INFORMATION (2)ELECTRICAL ONE-LINE PNL UNIT PNL UNIT PNL UNIT PNL UNIT PNL UNIT PNL HOUSE M PNL UNIT PNL UNIT PNL UNIT PNL UNIT PNL UNIT PNL UNIT PNL UNIT 2 STORY M 2 STORY M 2 STORY M 2 STORY M 2 STORY M 2 STORY M 2 STORY M 3 BED M 3 BED M STUDIO M STUDIO M ADA M 5765555555567 1 2 3 4223 G G 100/2 G 100/2 100/2 100/2 100/2 100/2 GGG 100/2 100/2 100/2 100/2 100/2 100/2 100/2 N.TS. SECONDARY VOLTAGE 120/240V, 1PH, 3W NEW 167 kVA, 240V, 1 PH PAD-MOUNTED XFMR BY FCL&P 800/2 800A JJN SCA= 30,519 @ 240V 49,981 @ 120V X SCA= 21,167 @ 240V 20,424 @ 120V X SCA= 9,676 @ 240V X SCA= 6,746 @ 240V X SCA= 4,591 @ 240V X SCA= 3,807 @ 240V XSCA= 3,251 @ 240V XSCA= 3,434 @ 240V X X SCA= 9,858 @ 240V X SCA= 4,080 @ 240V X SCA= 3,738 @ 240V X SCA= 3,413 @ 240V X SCA= 3,773 @ 240V X SCA= 11,433 @ 240V XSCA= 5,184 @ 240V VD= 1.13%X VD= 2.32%X METERSTACK GANGABLE GROUP METERING, NEMA 3R, 800 AMP, 100 AMP METER SOCKETS 120/240 VOLT, 1 PHASE, 3 WIRE IN 120/240 VOLT, 1 PHASE OUT, BRACED FOR 100,000 AIC, METERING AND PANELS SHALL BE SERIES RATED TO ALLOW 10,000 AIC BREAKERS IN TENANT AND HOUSE PANELS. PROVIDE DATA AT SHOP DRAWINGS AND PROVIDE LABELING OR SERIES RATING ON ALL EQUIPMENT UFER GROUND PER NEC 250 BLDG STEEL COLD WATER PIPE 3/4" X 10'-0" GROUND ROD MIN. 12'-0" CLAMP TO REBAR 3/4" X 10'-0" GROUND ROD SERIES RATING: 1. METER STACKS WITH SERIES RATED LOADSIDE CIRCUIT BREAKERS SHALL HAVE A MANUFACTURER'S LABEL STATING THE LISTING FOR THE SERIES COMBINATION INTERRUPTING RATING FOR THE LOADSIDE CIRCUIT BREAKER, IN COMPLIANCE WITH NEC SECTION 240-86. THIS SERIES RATING SHALL BE EQUAL TO OR GREATER THAN THE AVAILABLE SHORT-CIRCUIT CURRENT. 2. WHERE SERIES RATED COMBINATION ARE UTILIZED, THE ELECTRICAL CONTRACTOR SHALL AFFIX FIELD INSTALLED LABELS TO THE LOADSIDE CIRCUIT BREAKER PANELBOARD AND METER STACK LOAD CENTERS, IN COMPLIANCE WITH NEC SECTION 110-22. 3. IF THE MANUFACTURER/SUPPLIER/INSTALLER CANNOT SUPPLY TESTED AND LISTED SERIES RATED COMBINATIONS OF THE SPECIFIED LOADSIDE CIRCUIT BREAKERS, IT IS THEIR RESPONSIBILITY TO PROVIDE LOADSIDE CIRCUIT BREAKERS THAT HAVE FULLY RATED INTERRUPTING RATINGS EQUAL TO OR GREATER THAN THE SHORT-CIRCUIT CURRENT AVAILABLE AT THE LOADSIDE CIRCUIT BREAKERS. BREAKERS SHALL BE SERIES RATED FOR THE AVAILABLE FAULT CURRENT VALUES SHOWN. SERIES RATING SPECIFICATION Where series rating combinations are shown on the plans, the loadside circuit breakers supplied shall be test and listed as a series combination with the line side feeder fuses per the plans. Panelboards with series rated loadside circuit breakers shall have a manufacturer's label stating the listing for the series combination interrupting rating for the loadside circuit breakers and the lineside fuse (or circuit breaker) combination, in compliance with NEC Section 240-86. This series rating shall be equal to or greater than the available short-circuit current. Where series rated combinations are utilized, the electrical contractor shall affix field installed labels to the loadside circuit breaker panelboard and feeder switch/panelboard/switchboard, in compliance with NEC Section 110-22. As required in Section 110-22, the loadside panelboard/switchboard label shall be field marked with the short-circuit rating of the series combination, type circuit breaker for replacement, part number for the series rated lineside, feeder fuses and location/name of this fuse switch/panelboard/switchboard. The panel/switch with the lineside fuses (or circuit breaker) shall be field marked with short-circuit rating of the series combination, part number for fuse (or circuit breaker) replacement and the location/name of loadside, series rated panelboard/switchboard. If the manufacturer/supplier/installer cannot supply tested and listed series rated combinations of the specified loadside circuit breakers with the specified line side fuses, it is their responsibility to provide loadside circuit breakers that have fully rated interrupting ratings equal to or greater than the short-circuit current available at the loadside circuit breakers. VD= 2.10%XVD= 2.35% X VD= 2.07%X Studio ADA Studio Ground Level 3B2B 2 Story Units Two Appliance Circuits Laundry Circuit Range Dishwasher Disposal Dryer Furnace Gas Water Heater/Electronic Ignition Air Conditioning/Condensing Units Total 368712 Divided by 240 = Note: Per NEC Table 220.84 for 14 units a demand factor of 40% was used. Total Panel H Service Total 405 Sq. Ft. 462 Sq. Ft. 825 Sq. Ft. 1042 Sq. Ft. W. X 0.41 X X X X = = = = BUILDING CALCULATIONS 3 Watts = 3 Watts = 3 Watts = 3 Watts = 147485 615 615 50 665 1215 X 2 = 1386 X 1 = 2475 X 2 = 3126 X 7 = 3000 X 12 = 1500 X 12 = 12000 X 12 = 1200 X 12 = 1176 X 12 = 5000 X 12 = 1128 X 12 = 240 X 12 = 2928 X 12 = Watts Amps Amps Amps Amps 2430 1386 4950 21882 36000 18000 144000 14400 14112 60000 13536 2880 35136 368712 W W W W W W W W W W W W W W 405 Sq. Ft. X 3 Watts Two Appliance Circuit LaundryCircuit Range Dishwasher Disposal Dryer Furnace Gas Water Heater/Electronic Ignition First 10 KW at 100% Remainder at (16459) X 40% Condensing Unit at 100% 19512 W. ÷ 240V STUDIO CALCULATIONS = = = = = = = = = = = = = 1215 3000 1500 12000 1200 1176 5000 1128 240 26459 10000 6584 2928 19512 81 W. W. W. W. W. W. W. W. W. W. W. W. W. W. Amps 462 Sq. Ft. X 3 Watts Two Appliance Circuit LaundryCircuit Range Dishwasher Disposal Dryer Furnace Gas Water Heater/Electronic Ignition First 10 KW at 100% Remainder at (16630) X 40% Condensing Unit at 100% 19580 W. ÷ 240V ADA STUDIO CALCULATIONS = = = = = = = = = = = = = 1386 3000 1500 12000 1200 1176 5000 1128 240 26630 10000 6652 2928 19580 82 W. W. W. W. W. W. W. W. W. W. W. W. W. W. Amps 825 Sq. Ft. X 3 Watts Two Appliance Circuit LaundryCircuit Range Dishwasher Disposal Dryer Furnace Gas Water Heater/Electronic Ignition First 10 KW at 100% Remainder at (17719) X 40% Condensing Unit at 100% 20016 W. ÷ 240V GROUND LEVEL 3BD 2BTH CALCULATIONS = = = = = = = = = = = = = 2475 3000 1500 12000 1200 1176 5000 1128 240 27719 10000 7088 2928 20016 83 W. W. W. W. W. W. W. W. W. W. W. W. W. W. Amps 1042 Sq. Ft. X 3 Watts Two Appliance Circuit LaundryCircuit Range Dishwasher Disposal Dryer Furnace Gas Water Heater/Electronic Ignition First 10 KW at 100% Remainder at (18370) X 40% Condensing Unit at 100% 20276 W. ÷ 240V 2 STORY UNIT CALCULATIONS = = = = = = = = = = = = = 3126 3000 1500 12000 1200 1176 5000 1128 240 28370 10000 7348 2928 20276 84 W. W. W. W. W. W. W. W. W. W. W. W. W. W. Amps GROUP METERING ELEVATION FINAL GRADE N.T.S. NOTE: 1. EACH METER MUST BE PERMANENTLY LABELED TO IDENTIFY CUSTOMER ADDRESS. 2. LABEL MUST BE CONSTRUCTED OF ENGRAVED BRASS. AND ENGRAVED PHONOLIC PLAQUE (WHITE LETTERS ON BLACK). 3. FAULT LIMITING DISCONNECTS SHALL BE INSTALLED ON THE LINE SIDE OF THE METER. FUSE SIZE AND TYPE SHALL LIMIT FAULT CURRENT TO THE METER HOUSING TO 10,000 AMPS OR LESS PER THE NEC. 4. THE FUSED DISCONNECT SHALL BE PURCHASED AND INSTALLED BY THE CUSTOMER AND SHALL INCLUDE PROVISIONS FOR A FORT COLLINS LIGHT AND POWER COMPANY SEAL. 5. SEALS WILL BE USED BY FORT COLLINS LIGHT AND POWER COMPANY TO SECURE THE ENCLOSURE FROM UNAUTHORIZED ENTRY BUT ALLOW THE CUSTOMER EMERGENCY ACCESS FOR FUSE REPLACEMENT. 6. ALL REQUIREMENTS PER FORT COLLINS LIGHT AND POW ER AND COMMUNICATIONS INCLUDING LEVER BYPASS ON METER ASSEMBLIES. MIN 7 1/2" MAX 75" MIN 8 1/2" 800/2 MFS SEALABLE ENCLOSURE KEY FEEDER SCHEDULE 1 4 RUNS [(3 #350 KCMIL XHHW CU) 3"C.] (#3/0 CU GRD) 1"C. (#6 CU GRD) 3/4"C. (#4 CU GRD) 3/4"C. (3 #2 THWN AL & GRD) METAL CLAD CABLE. (3 #1 THWN AL & GRD) METAL CLAD CABLE. (3 #1/0 THWN AL & GRD) METAL CLAD CABLE. 2 3 4 5 6 7 DESIGN IN PROGRESS NOT FOR CONSTRUCTION 8/27/2021 4645 W. 18TH ST, SUITE #200 GREELEY, COLORADO 80634 GREELEY: (970) 330-3266 & ASSOCIATES, LLC ELECTRICAL ENGINEERS [au workshop ARCHITECTS+URBANISTS ]- PLOT DATE 5 4 3 2 1 A B C D ISSUE DATE: PROJECT #: T - 970.430.5220 401 LINDEN STREET, SUITE 2-221 FORT COLLINS, CO, 80524 © 2021 www.auworkshop.co P R O G R E S S S E T N O T F O R C O N S T R U C T I O N 8/27/2021 1:51:42 PME500 1904 ELECTRICAL ONE-LINE HOWES SIX TWO NINE 629 S. HOWES STREET FORT COLLINS, CO ST VRAIN LAND HOLDINGS SCHEMATIC DESIGN 08/27/2021 1/8" = 1'-0" GROUP METERING ELEVATION