Loading...
HomeMy WebLinkAboutPOUDRE VALLEY PLAZA MIXED-USE - MJA210003 - SUBMITTAL DOCUMENTS - ROUND 2 - MODIFICATION REQUESTMODIFICATION REQUEST #1 LUC SECTION 3.5.1(I)(1) : Outdoor Storage Areas/Mechanical Equipment. (1) No areas for outdoor storage, trash collection or compaction, loading or other such uses shall be located within twenty (20) feet of any public street, public sidewalk or internal pedestrian way. Notwithstanding the foregoing, areas for trash collection may be located within twenty (20) feet of an internal pedestrian way. MODIFICATION JUSTIFICATION: by reason of exceptional physical conditions or other extraordinary and exceptional situations, unique to such property, including, but not limited to, physical conditions such as exceptional narrowness, shallowness or topography, or physical conditions which hinder the owner’s ability to install a solar energy system, the strict application of the standard sought to be modified would result in unusual and exceptional practical difficulties, or exceptional or undue hardship upon the owner of such property, provided that such difficulties or hardship are not caused by the act or omission of the applicant; or, and will continue to advance the purposes of the Land Use Code as contained in Section 1.2.2. The property has an existing trash enclosure that has been in use for many years. The existing enclosure serves other buildings within the Poudre Plaza PUD. Due to limited space along the Arbor Avenue frontage with the existing retention area and walls there is no other location to build a new structure. Existing plantings in front of the dumpster enclosure shall remain in place as well as new plantings that will be added. MODIFICATION REQUESTED: The existing structure shall be allowed to remain in its existing location (8’-0” from R.O.W.) and be expanded to serve the new uses on Lot 7 with a setback of 10’-9” from R.O.W. Existing planting to remain and be added to Existing sidewalk, retaining wall and retention area Area for additional plantings Modification Requests POUDRE VALLEY PLAZA MIXED USE UP 22'-912"6'-31 2" 6'-11 2" 2'-71 2"10'-9"8'-0"0 5'10'10'20'N O R T H Arbor Avenue R.O.W. Existing enclosure walls Existing sidewalk Existing retention area Expanded enclosure walls Existing and new planting bed with shrubs and tree Modification Requests POUDRE VALLEY PLAZA MIXED USE LOT 7 UPVANT 0 15'30'30'60'N O R T H MODIFICATION REQUEST #2 LUC SECTION 3.2.1(5)(c) : (5) Parking Lot Interior Landscaping (c) Landscaped Islands. In addition to any pedestrian refuge areas, each landscaped island shall include one (1) or more canopy shade trees, be of length greater than eight (8) feet in its smallest dimension, include at least eighty (80) square feet of ground area per tree to allow for root aeration, and have raised concrete curbs. MODIFICATION JUSTIFICATION: by reason of exceptional physical conditions or other extraordinary and exceptional situations, unique to such property, including, but not limited to, physical conditions such as exceptional narrowness, shallowness or topography, or physical conditions which hinder the owner’s ability to install a solar energy system, the strict application of the standard sought to be modified would result in unusual and exceptional practical difficulties, or exceptional or undue hardship upon the owner of such property, provided that such difficulties or hardship are not caused by the act or omission of the applicant; or, and will continue to advance the purposes of the Land Use Code as contained in Section 1.2.2. The property has limited areas that meet the requirements fro Light and Power access to the transformer. The transformer needs to be within 10’ of a vehicular drive aisle. The previously proposed location along Arbor Avenue was denied by Light and Power. Light and Power has indicated that this island would be where the transformer needs to be in order to be serviceable. Due to the size of the transformer and required clearances a tree is not able to fit in the island. Building perimeter tree stocking is proposed above the required amount of 12 to the provided quantity of 22 (+10 trees). MODIFICATION REQUESTED: Parking island tree requirement shall be offset by increased building perimeter tree stocking. Transformer location Modification Requests POUDRE VALLEY PLAZA MIXED USE