Loading...
HomeMy WebLinkAboutFORT COLLINS NISSAN-KIA - PDP210017 - SUBMITTAL DOCUMENTS - ROUND 1 - GEOTECHNICAL (SOILS) REPORT REPORT COVER PAGE Geotechnical Engineering Report __________________________________________________________________________ Fort Collins Nissan and Kia Dealerships Fort Collins, Colorado April 7, 2021 Terracon Project No. 20215013 Prepared for: TCC Corporation Windsor, Colorado Prepared by: Terracon Consultants, Inc. Fort Collins, Colorado Responsive ■ Resourceful ■ Reliable 1 REPORT TOPICS INTRODUCTION ............................................................................................................. 1 SITE CONDITIONS ......................................................................................................... 1 PROJECT DESCRIPTION .............................................................................................. 2 GEOTECHNICAL CHARACT ERIZATION ...................................................................... 3 GEOTECHNICAL OVERVIEW ....................................................................................... 5 EARTHWORK................................................................................................................. 6 SHALLOW FOUNDATIONS ......................................................................................... 13 SEISMIC CONSIDERATIONS ...................................................................................... 14 FLOOR SLABS............................................................................................................. 15 PAVEMENTS ................................................................................................................ 16 CORROSIVITY.............................................................................................................. 19 GENERAL COMMENTS ............................................................................................... 19 Note: This report was originally delivered in a web-based format. Orange Bold text in the report indicates a referenced section heading. The PDF version also includes hyperlinks which direct the reader to that section and clicking on the GeoReport logo will bring you back to this page. For more interactive features, please view your project online at client.terracon.com. ATTACHMENTS EXPLORATION AND TESTING PROCEDURES SITE LOCATION AND EXPLORATION PLANS EXPLORATION RESULTS SUPPORTING INFORMATION Note: Refer to each individual Attachment for a listing of contents. Geotechnical Engineering Report Fort Collins Nissan and Kia Dealerships ■ Fort Collins, Colorado April 7, 2021 ■ Terracon Project No. 20215013 Responsive ■ Resourceful ■ Reliable i REPORT SUMMARY Topic 1 Overview Statement 2 Project Overview A geotechnical exploration has been performed for the proposed Fort Collins Nissan and Kia Dealerships to be constructed west of the intersection of South College Avenue and Crestridge Drive in Fort Collins, Colorado. Eight (8) borings were performed to depths of approximately 15 to 30 feet below existing site grades. Subsurface Conditions Subsurface conditions encountered in our exploratory borings generally consisted of about 1 to 2 feet of lean clay with varying amounts of sand over sandstone bedrock. Sandstone bedrock was generally hard to very hard with cemented lenses. Boring logs are presented in the Exploration Results section of this report. Groundwater Conditions Groundwater was encountered in one of our test borings at a depth of about 14 feet below existing site grades at the time of drilling. Groundwater was not encountered during drilling in any of our other test borings. Groundwater levels can fluctuate in response to site development and to varying seasonal and weather conditions, irrigation on or adjacent to the site and fluctuations in nearby water features. However, we do not believe groundwater will significantly impact the proposed construction. Geotechnical Concerns ■ As previously stated, bedrock was encountered at depths ranging from about 1 to 3 feet below existing site grades. Bedrock was generally hard to very hard with cemented lenses throughout. Excavation penetrating the bedrock may require the use of specialized heavy-duty equipment, together with ripping or jack-hammering to advance the excavation and facilitate rock break-up and removal. Consideration should be given to obtaining a unit price for difficult excavation in the contract documents for the project. ■ A sample of on-site soils exhibited 2.3 percent swell upon wetting. Expansive soils are anticipated to be encountered in the clay soils in the upper approximately 1 to 3 feet below existing site grades above the sandstone bedrock, these conditions constitute a geologic hazard. This report provides recommendations to help mitigate the effects of soil shrinkage and expansion. However, even if these procedures are followed, some movement and cracking in the structures, pavements, and flatwork is possible. The severity of cracking and other damage such as uneven floor slabs and flat work will probably increase if modification of the site results in excessive wetting or drying of the expansive clays. Eliminating the risk of movement and cosmetic distress is generally not feasible, but it may be possible to further reduce the risk of movement if significantly more expensive measures are used during construction. It is imperative the recommendations described in section Grading and Drainage section of the Earthwork section of this report be followed to reduce potential movement. Clay soils used as backfill or fill on the site should be probably moisture conditioned prior to placement to help mitigate the effects of soil shrinkage and expansion. ■ An existing Nissan dealership and associated parking and drive areas currently occupy the south side of the site. Although not encountered in our exploratory borings, based on the existing structures we anticipate existing undocumented fill could be encountered at the site, particularly under the existing building and associated structures. If fill is encountered, we do not possess any information regarding whether the fill was placed under the observation of a geotechnical engineer. Undocumented fill can present a greater than normal risk of post- construction movement of foundations, slabs, pavements and other site improvements supported on or above these materials. Consequently, it is our opinion existing fill on the site (if any) should not be relied upon for support and Geotechnical Engineering Report Fort Collins Nissan and Kia Dealerships ■ Fort Collins, Colorado April 7, 2021 ■ Terracon Project No. 20215013 Responsive ■ Resourceful ■ Reliable ii Topic 1 Overview Statement 2 should be removed down to native soil, moisture conditioned and recompacted prior to new fill placement and/or construction. Earthwork On-site soils typically appear suitable for use as general engineered fill and backfill on the site provided they are placed and compacted as described in this report. Import materials (if needed) should be evaluated and approved by Terracon prior to delivery to the site. Earthwork recommendations are presented in the Earthwork section of this report. Grading and Drainage The amount of movement of foundations, floor slabs, pavements, etc. will be related to the wetting of underlying supporting soils. Therefore, it is imperative the recommendations discussed in the Grading and Drainage section of the Earthwork section this report be followed to reduce potential movement. As discussed in the Grading and Drainage section of this report, surface drainage should be designed, constructed and maintained to provide rapid removal of surface water runoff away from the proposed buildings and pavements. Water should not be allowed to pond adjacent to foundations or on pavements and conservative irrigation practices should be followed to avoid wetting foundation/slab soils and pavement subgrade. Excessive wetting of foundations/slab soils and subgrade can cause movement and distress to foundations, floor slabs, concrete flatwork and pavements. Foundations The proposed buildings can be supported by a shallow, spread footing foundation system. Design recommendations for foundations for the proposed structures and related structural elements are presented in the Shallow Foundations section of this report. Floor Systems We believe concrete slab-on-grade floor systems can be used for the proposed buildings provided the soils are over-excavated to a depth of at least 12 inches below the proposed floor slab and replaced with moisture conditioned, properly compacted engineered fill. On-site soils are suitable as over-excavation backfill below floor slabs. Design recommendations for floor slabs for the proposed structures and related structural elements are presented in the Floor Slabs section of this report. Pavements Recommended Pavement thicknesses for this project include 4½ inches of asphalt over no of aggregate base course in light-duty parking areas and 4½ inches of asphalt over 6 inches of aggregate base course in heavy-duty drive lanes and loading areas. Additional pavement section alternatives and discussion are presented in the report. Seismic Considerations As presented in the Seismic Considerations section of this report, the International Building Code, which refers to Section 20 of ASCE 7, indicates the seismic site classification for this site is C. Construction Observation and Testing Close monitoring of the construction operations and implementing drainage recommendations discussed herein will be critical in achieving the intended foundation, slab and pavement performance. We therefore recommend that Terracon be retained to monitor this portion of the work. General Comments This section contains important information about the limitations of this geotechnical engineering report. 1. If the reader is reviewing this report as a pdf, the topics (bold orange font) above can be used to access the appropriate section of the report by simply clicking on the topic itself. 2. This summary is for convenience only. It should be used in conjunction with the entire report for design making and design purposes. It should be recognized that specific details were not included or fully developed in this section, and the report must be read in its entirety for a comprehensive understanding of the items contained herein. Responsive ■ Resourceful ■ Reliable 1 INTRODUC TION Geotechnical Engineering Report Fort Collins Nissan and Kia Dealerships West of South College Avenue and Crestridge Drive Fort Collins, Colorado Terracon Project No. 20215013 April 7, 2021 INTRODUCTION This report presents the results of our subsurface exploration and geotechnical engineering services performed for the proposed Fort Collins Nissan and Kia Dealerships to be located west of the intersection of South College Avenue and Crestridge Drive in Fort Collins, Colorado. The purpose of these services is to provide information and geotechnical engineering recommendations relative to: ■ Subsurface soil and rock conditions ■ Foundation design and construction ■ Groundwater conditions ■ Floor system design and construction ■ Site preparation and earthwork ■ Seismic considerations ■ Demolition considerations ■ Lateral earth pressures ■ Excavation considerations ■ Pavement design and construction The geotechnical engineering scope of services for this project i ncluded the advancement of eight (8) test borings to depths ranging from approximately 15 to 30 feet below existing site grades. Maps showing the site and boring locations are shown in the Site Location and Exploration Plan sections, respectively. The results of the laboratory testing performed on soil and bedrock samples obtained from the site during the field exploration are included on the boring logs and as separate graphs in the Exploration Results section of this report. SITE CONDITIONS The following description of site conditions is derived from our site visit in association with the field exploration and our review of publicly available geologic and topographic maps. Item Description Parcel Information The project site is located west of the intersection of South College Avenue and West Crestridge Drive in Fort Collins, Colorado. The approximate Latitude/Longitude of the center of the site is 40.5066° N/105.0782°W (Please refer to Site Location). Existing Improvements The north portion of the site is currently vacant land with some two-track roads and walking trails. The south portion of the site is currently occupied by an existing Nissan Dealership and associated parking and drive areas. Geotechnical Engineering Report Fort Collins Nissan and Kia Dealerships ■ Fort Collins, Colorado April 7, 2021 ■ Terracon Project No. 20215013 Responsive ■ Resourceful ■ Reliable 2 Item Description Surrounding Developments The site is bordered to the west by vacant land followed by an existing railroad and single-family residential developments. To the north of the site is the existing Fossil Creek followed by vacant land and single-family residential developments. To the east and south of the site are commercial developments followed by single-family residential developments Current Ground Cover The current ground cover in areas of exploration consisted of native grasses and weeds in the north portion of the site and concrete surfacing in the south portion of the site. Existing Topography The south portion of the site is relatively flat. The north portion of the site has rolling hills and generally slopes down from south to north towards Fossil Creek. PROJECT DESCRIPTION Our final understanding of the project conditions is as follows: Item Description Information Provided Project information was provided to us through the following: ■ Conversation with the client and project team. ■ Project concept plans, prepared by Infusion Architects and dated February 26, 2021. Project Description We understand the project includes the demolition of the existing Nissan dealership building, and associated parking and drive areas and the construction of new Nissan and Kia dealerships. Parking and drive areas, access lanes, a new roadway and new utilities are also planned for the project. Proposed Construction We understand the project includes the following construction: ■ A 1 to 2-story new 40,630 square-foot Nissan dealership building, anticipated to be supported on shallow foundations ■ A new 1 to 2-story 19,750 square-foot Kia dealership building, anticipated to be supported on shallow foundations ■ Fill on the north side of the site to avoid steep grades in the planned parking area ■ New inventory parking lot planned on west side of Venus Avenue We understand the following may also be included in the project, however exploration and recommendations for these aspects of the project were not included in our base geotechnical engineering scope. ■ An option for turn lanes from South College Avenue onto Crestridge Drive or an option to abandon Crestridge drive and create a private right in/out of the Colorado Department of Transportation (CDOT) right of way ■ A new city street wrapping around the west side of the proposed site connecting South College Avenue to Venus Avenue Geotechnical Engineering Report Fort Collins Nissan and Kia Dealerships ■ Fort Collins, Colorado April 7, 2021 ■ Terracon Project No. 20215013 Responsive ■ Resourceful ■ Reliable 3 Item Description Maximum Loads (assumed) ■ Columns: 50 to 100 kips ■ Walls: 1 to 3 kips per linear foot (klf) ■ Slabs: 150 pounds per square foot (psf) Grading/Slopes We anticipate minor cuts and fills on the order of 5 feet or less will be required to achieve proposed grades on the majority of the site. We anticipate significantly deeper fills, on the order of up to 20 to 30 feet could be required on the north portion of the site in the area of the proposed parking area. Below-grade Structures We understand no below-grade are planned for this site. Pavements ■ We assume both rigid (concrete) and flexible (asphalt) pavement sections are being considered. ■ Parking and drive lanes were designed based on National Asphalt Pavement Associations (NAPA) and the American Concrete Institute (ACI). If project information or assumptions vary from what is described above or if location of construction changes, we should be contacted as soon as possible to confirm and/or modify our recommendations accordingly. GEOTECHNICAL CHARACTERIZATION Subsurface Profile We have developed a general characterization of the subsurface conditions based upon our review of the subsurface exploration, laboratory data, geologic setting and our understanding of the project. This characterization, termed GeoModel, forms the basis of our geotechnical calculations and evaluation of site pre paration and foundation options. Conditions encountered at each exploration point are indicated on the individual logs. The individual logs and the GeoModel can be found in the Exploration Results section this report. Model Layer Layer Name General Description Approximate Depth to Bottom of Stratum - Surface Material Concrete surfacing over aggregate base course to native grasses and weeds in clayey silty sand. About 6 inches below existing site grades. 1 Lean Clay Lean clay with sand to sandy lean clay, brown to light brown, stiff to very stiff. About 1 to 3 feet below existing site grades. 2 Bedrock Sandstone to siltstone bedrock with trace amounts of clay, cemented sandstone lenses throughout, light brown to tan with orange and gray, hard to very hard. To the maximum depths of exploration of about 15 to 30 feet below existing site grades. Geotechnical Engineering Report Fort Collins Nissan and Kia Dealerships ■ Fort Collins, Colorado April 7, 2021 ■ Terracon Project No. 20215013 Responsive ■ Resourceful ■ Reliable 4 As noted in General Comments, this characterization is based upon widely spaced explora tion points across the site and variations are likely. Groundwater Conditions The boreholes were observed while drilling and shortly after completion for the presence and level of groundwater. The water levels observed in the boreholes are noted on the attached boring logs, and are summarized below: Boring Number Depth to Groundwater While Drilling, ft. B-1 14 These observations represent short-term groundwater conditions at the time of and shortly after the field exploration and may not be indicative of other times or at other locations. Groundwater levels can be expected to fluctuate with varying seasonal and weather conditions, and other factors. Groundwater level fluctuations occur due to seasonal variations in the water levels present in nearby water features, amount of rainfall, runoff and other factors not evident at the time the borings was/were performed. Therefore, groundwater levels during construction or at other times in the life of the structure(s) may be higher or lower than the level s indicated on the boring logs. The possibility of groundwater level fluctuations should be considered when developing the design and construction plans for the project. Groundwater was not observed in the remaining borings while drilling, or for the sho rt duration the borings could remain open. However, this does not necessarily mean the borings terminated above groundwater, or the water levels summarized above are stable groundwater levels. Due to the low permeability of the soils encountered in the borings, a relatively long period may be necessary for a groundwater level to develop and stabilize in a borehole. Long term observations in piezometers or observation wells sealed from the influence of surface water are often required to define groundwater levels in materials of this type. Laboratory Testing A representative soil sample selected for swell -consolidation testing exhibited 2.3 percent swell when wetted. The sandstone bedrock is considered to have low expansive potential or non - expansive. Samples of site soils and bedrock selected for plasticity testing exhibited low to moderate plasticity with liquid limits ranging from non -plastic to 32 and plasticity indices ranging from non-plastic to 15. Laboratory test results are presented in the Exploration Results section of this report. Geotechnical Engineering Report Fort Collins Nissan and Kia Dealerships ■ Fort Collins, Colorado April 7, 2021 ■ Terracon Project No. 20215013 Responsive ■ Resourceful ■ Reliable 5 GEOTECHNICAL OVERVIEW Based on subsurface conditions encountered in the borings, the site appears suitable for the proposed construction from a geotechnical point of view provided certain precautions and design and construction recommendations described in this report are followed and the owner understands the inherent risks associated with construction on sites underlain by expansive soils. We have identified several geotechnical conditions that could impact design, construction and performance of the proposed structures, pavements, and other site improvements. These included shallow bedrock and expansive soils and areas that could have existing undocumented fill. These conditions will require particular attention in project planning, design and during construction and are discussed in greater detail in the following sections. Shallow Bedrock As previously stated, bedrock was measured at depths ranging from about 1 to 3 feet below existing site grades. Bedrock was generally hard to very hard with cemented lenses throughout. Excavation penetrating the bedrock may require the use of specialized heavy -duty equipment, together with ripping or jack-hammering to advance the excavation a nd facilitate rock break-up and removal. Consideration should be given to obtaining a unit price for difficult excavation in the contract documents for the project. Expansive Soils and Bedrock As previously stated, a sample of on -site soils exhibited 2.3 percent swell upon wetting. Expansive soils are anticipated to be encountered in the clay soils in the upper approximately 1 to 3 feet below existing site grades above the sandstone bedrock, these conditions constitute a geologic hazard. This report provides recommendations to help mitigate the effects of soil shrinkage and expansion. However, even if these procedures are followed, some movement and cracking in the structures, pavements, and flatwork is possible. The severity of cracking and other damage such as uneven floor slabs and flat work will probably increase if modification of the site results in excessive wetting or drying of the expansive clays. Eliminating the risk of movement and cosmetic distress is generally not feasible, but it may be possible to further reduce the risk of movement if significantly more expensive measures are used during construction . It is imperative the recommendations described in section Grading and Drainage section of the Earthwork section of this report be followed to reduce potential movement. Clay soils used as backfill or fill on the site should be probably moisture conditioned prior to placement to help mitigate the effects of soil shrinkage and expansion. Existing, Undocumented Fill As previously noted, an existing Nissan dealership and associated parking and drive areas currently occupy the south side of the site. Although not encountered in our exploratory borings, based on the existing structures we anticipate existing undocum ented fill could be encountered Geotechnical Engineering Report Fort Collins Nissan and Kia Dealerships ■ Fort Collins, Colorado April 7, 2021 ■ Terracon Project No. 20215013 Responsive ■ Resourceful ■ Reliable 6 at the site, particularly under the existing building and associated structures. If fill is encountered, we do not possess any information regarding whether the fill was placed under the observation of a geotechnical enginee r. Undocumented fill can present a greater than normal risk of post - construction movement of foundations, slabs, pavements and other site improvements supported on or above these materials. Consequently, it is our opinion existing fill on the site (if any) should not be relied upon for support and should be removed down to native soil, moisture conditioned and recompacted prior to new fill placement and/or construction. Foundation and Floor System Recommendations The proposed buildings can be supported by a shallow, spread footing foundation system. Design recommendations for foundations for the proposed structure s and related structural elements are presented in the Shallow Foundations section of this report. W e believe concrete slab-on-grade floor systems can be used for the proposed building s provided the soils are over-excavated to a depth of at least 12 inches below the proposed floor slab and replaced with moisture conditioned, properly compacted engineered fill. On-site soils are suitable as over-excavation backfill below floor slabs. Design recommendations for floor slabs for the proposed structures and related structural elements are presented in the Floor Slabs section of this report. The General Comments section provides an understanding of the report limitations. EARTHWORK The following presents recommendations for site preparation, demolition, excavation, subgrade preparation, fill materials, compaction requirements, utility trench backfill, grading and drainage and exterior slab design and construction. Earthwork on the project should be observed and evaluated by Terracon. Evaluation of earthwork should include observation and/or testing of over- excavation, subgrade preparation, placement of engineered fills, subgrade stabilization and other geotechnical conditions exposed during the construction of the project. Site Preparation Prior to placing any fill, strip and remove existing vegetation, topsoil, and any other deleterious materials from the proposed construction areas. Stripped organic materials should be wasted from the site or used to re -vegetate landscaped areas or exposed slopes after completion of grading operations. P rior to the placement of fills, the site should be graded to create a relatively level surface to receive fill, and to provide for a relatively uniform thickness of fill beneath proposed structures. Geotechnical Engineering Report Fort Collins Nissan and Kia Dealerships ■ Fort Collins, Colorado April 7, 2021 ■ Terracon Project No. 20215013 Responsive ■ Resourceful ■ Reliable 7 If fill is placed in areas of the site where existing slopes are steeper than 5:1 (horizontal:vertical), the area should be benched to reduce the potential for slippage between existing slopes and fills. Benches should be wide enough to accommodate compaction and earth moving equipment, and to allow placement of horizontal lifts of fill. Demolition Demolition of the existing Nissan dealership building, and associated parking and drive areas should include complete removal of all foundation systems, below -grade structural elements, pavements, and exterior flat work within the proposed construction area. This should include removal of any utilities to be abandoned along with any loose utility trench backfill or loose backfill found adjacent to existing foundations. All materials derived from the demolition of e xisting structures and pavements should be removed from the site. The types of foundation systems supporting the existing building are not known. If some or all of the existing buildings are supported by drilled piers, the existing piers should be truncated a minimum depth of 3 feet below areas of planned new construction. Consideration could be given to re-using the asphalt and concrete provided the materials are processed and uniformly blended with the on -site soils. Asphalt and/or concrete materials should be processed to a maximum size of 2 inches and blended at a ratio of 30 percent asphalt/concrete to 70 percent of on-site soils. Excavation It is anticipated that excavations for the proposed construction can be accomplished with conventional earthmoving equipment. As previously stated, shallow bedrock was encountered at depths of about 1 to 3 feet below existing site grades. In addition, cemented lenses were encountered in the sandstone bedrock throughout the site. Excavation penetrating the bedrock may require the use of specialized heavy-duty equipment, together with ripping or jack-hammering advance the excavation and facilitate rock break-up and removal. Consideration should be given to obtaining a unit price for difficult excavation in the contract documents for the project. The soils to be excavated can vary significantly across the site as their classifications are based solely on the materials encountered in widely-spaced exploratory test borings. The contractor should verify that similar conditions exist throughout the proposed area of excavation. If different subsurface conditions are encountered at the time of construction, the actual conditions should be evaluated to determine any excavation modifications necessary to maintain safe conditions. Although evidence of fills or underground facilities such as grease pits, septic tanks, vaults, basements, and utilities was not observed during the site reconnaissance, such features could be encountered during construction. If unexpected underground facilities are encountered, such Geotechnical Engineering Report Fort Collins Nissan and Kia Dealerships ■ Fort Collins, Colorado April 7, 2021 ■ Terracon Project No. 20215013 Responsive ■ Resourceful ■ Reliable 8 features should be removed, and the excavation thoroughly cleaned prior to backfill placement and/or construction. Any over-excavation that extends below the bottom of foundation elevation should extend laterally beyond all edges of the foundations at least 8 inches per foot of over -excavation depth below the foundation base elevation. The over-excavation should be backfilled to the foundation base elevation in accordance with the recommendations presented in this report. Depending upon depth of excavation and seasonal conditions, surface water infiltration and/or groundwater may be encountered in excavations on the site. It is anticipated that pumping from sumps may be utilized to control water within excavations. The subgrade soil conditions should be evaluated during the excavation process and the stability of the soils determined at that time by the contractors’ Competent Person. Slope inclinations flatter than the OSHA maximum values may have to be used. The individual contractor(s) should be made responsible for designing and constructing stable, temporary excavations as required to maintain stability of both the excavation sides and bottom. All excavations should be sloped or shored in the interest of safety following local, and federal regulations, including current OSHA excavation and trench safety standards. As a safety measure, it is recommended that all vehicles and soil piles be kept a minimum lateral distance from the crest of the slope equal to the slope height. The exposed slope face should be protected against the elements. Subgrade Preparation After the existing site features or existing topsoil has been removed from the construction area, the top 10 inches of the exposed ground surface s hould be scarified, moisture conditioned, and recompacted to at least 95 percent of the maximum dry unit weight as determined by ASTM D698 before any new fill or foundation or pavement is placed . Although not anticipated, if pockets of soft, loose, or otherwise unsuitable materials are encountered at the bottom of the foundation excavations and it is inconvenient to lower the foundations, the proposed foundation elevations may be reestablished by over -excavating the unsuitable soils and backfilling with c ompacted engineered fill or lean concrete. Geotechnical Engineering Report Fort Collins Nissan and Kia Dealerships ■ Fort Collins, Colorado April 7, 2021 ■ Terracon Project No. 20215013 Responsive ■ Resourceful ■ Reliable 9 After the bottom of the excavation has been compacted, engineered fill can be placed to bring the building pad and pavement subgrade to the desired grade. Engineered fill should be placed in accordance with the recommendations presented in subsequent sections of this report. The stability of the subgrade may be affected by precipitation, repetitive construction traffic or other factors. If unstable conditions develop, workability may be improved by scari fying and drying. Alternatively, over-excavation of wet zones and replacement with granular materials may be used, or crushed gravel and/or rock can be tracked or “crowded” into the unstable surface soil until a stable working surface is attained. Lightweight excavation equipment may also be used to reduce subgrade pumping. Fill Materials The on-site soils or approved granular and low plasticity cohesive imported materials may be used as fill material. The earthwork contractor should expect significant mechanical processing and moisture conditioning of the site soils and/or bedrock will be needed to achieve proper compaction Bedrock excavated during site development and construction can be reused as fill provided the material is broken down and thorough ly processed to a “soil-like” consistency, with no particles greater than 2 inches in size. Consideration could be given to re-using the asphalt and concrete from the demolition of the existing structures, provided the materials are processed and uniformly blended with the on-site soils. Asphalt and/or concrete materials should be processed to a maximum size of 2 inches and blended at a ratio of 30 percent asphalt/concrete to 70 percent of on-site soils. Imported soils (if required) should meet the following material property requirements: Gradation Percent finer by weight (ASTM C136) 4” 100 Geotechnical Engineering Report Fort Collins Nissan and Kia Dealerships ■ Fort Collins, Colorado April 7, 2021 ■ Terracon Project No. 20215013 Responsive ■ Resourceful ■ Reliable 10 Gradation Percent finer by weight (ASTM C136) 3” 70-100 No. 4 Sieve 30-100 No. 200 Sieve 50 (max.) Soil Properties Values Liquid Limit 35 (max.) Plasticity Index 15 (max.) Other import fill materia ls types may be suitable for use on the site depending upon proposed application and location on the site, and could be tested and approved for use on a case -by-case basis. Compaction Requirements We understand significant fills, on the order of about 15 f eet are anticipated on the north side of the site. Engineered fill should be placed and compacted in horizontal lifts, using equipment and procedures that will produce recommended moisture contents and densities throughout the lift. Item Description Fill lift thickness 9 inches or less in loose thickness when heavy, self- propelled compaction equipment is used 4 to 6 inches in loose thickness when hand-guided equipment (i.e. jumping jack or plate compactor) is used Minimum compaction requirements 95 percent of the maximum dry unit weight as determined by ASTM D698 Moisture content cohesive soil (clay) -1 to +3 % of the optimum moisture content Moisture content cohesionless soil (sand) -3 to +3 % of the optimum moisture content 1. We recommend engineered fill be tested for moisture content and compaction during placement. Should the results of the in-place density tests indicate the specified moisture or compaction limits have not been met, the area represented by the test should be reworked and retested as required until the specified moisture and compaction requirements are achieved. 2. Specifically, moisture levels should be maintained low enough to allow for satisfactory compaction to be achieved without the fill material pumping when proof rolled. 3. Moisture conditioned clay materials should not be allowed to dry out. A loss of moisture within these materials could result in an increase in the material’s expansive potential. Subsequent wetting of these materials could result in undesirable movement. Utility Trench Backfill All trench excavations should be made with sufficient working space to permit construction including backfill placement and compaction. Geotechnical Engineering Report Fort Collins Nissan and Kia Dealerships ■ Fort Collins, Colorado April 7, 2021 ■ Terracon Project No. 20215013 Responsive ■ Resourceful ■ Reliable 11 All underground piping within or near the proposed structures should be designed with flexible couplings, so minor deviations in alignment do not result in breakage or distress. Utility knockouts in foundation walls should be oversized to accommodate differential movements. It is imperative that utility trenches be properly backfilled with relatively clean materials. If utility trenches are backfilled with relatively clean granular material, they should be capped with at least 18 inches of cohesive fill in non-pavement areas to reduce the infiltration and conveyance of surface water through the trench backfill. Utility trenches are a common source of water infiltration and migration. All utility trenches that penetrate beneath the buildings should be effectively sealed to restrict water intrusion and flow through the trenches that could migrate below the buildings. We recommend constructing an effective clay “trench plug” that extends at least 5 feet out from the face of the building exteriors. The plug material should consist of clay compacted at a water content at or above the soil’s optimum water content. The clay fill should be placed to completely surround the utility line and be compacted in accordance with recommendations in this report. It is strongly recommended that a representative of Terracon provide full -time observation and compaction testing of trench backfill within building and pavement areas. Grading and Drainage Grades must be adjusted to provide effective drainage away from the proposed building s and existing buildings during construction and maintained throughout the life of the proposed project. Infiltration of water into foundation excavations must be prevented during construction. Landscape irrigation adjacent to foundations should be minimized or eliminated. Water permitted to pond near or adjacent to the perimeter of the s tructures (either during or post-construction) can result in significantly higher soil movements than those discussed in this report. As a result , any estimations of potential movement described in this report cannot be relied upon if positive drainage is not obtained and maintained, and water is allowed to infiltrate the fill and/or subgrade. Exposed ground (if any) should be sloped at a minimum of 10 percent grade for at least 5 feet beyond the perimeter of the proposed buildings, where possible. Lo cally, flatter grades may be necessary to transition ADA access requirements for flatwork. The use of swales, chases and/or area drains may be required to facilitate drainage in unpaved areas around the perimeter of the buildings. Backfill against foundat ions and exterior walls should be properly compacted and free of all construction debris to reduce the possibility of moisture infiltration. After construction of the proposed buildings and prior to project completion, we recommend verification of final g rading be performed to document positive drainage , as described above, has been achieved. Flatwork and pavements will be subject to post -construction movement. Maximum grades practical should be used for paving and flatwork to prevent areas where water c an pond. In addition, allowances in final grades should take into consideration post -construction movement Geotechnical Engineering Report Fort Collins Nissan and Kia Dealerships ■ Fort Collins, Colorado April 7, 2021 ■ Terracon Project No. 20215013 Responsive ■ Resourceful ■ Reliable 12 of flatwork, particularly if such movement would be critical. Where paving or flatwork abuts the structures, care should be taken that joints are properly sealed and maintained to prevent the infiltration of surface water. Planters located adjacent to structures (if any) should preferably be self -contained. Sprinkler mains and spray heads should be located a minimum of 5 feet away from the buildin g line(s). Low-volume, drip style landscaped irrigation should be used sparingly near the building. Roof drains should discharge on to pavements or be extended away from the structures a minimum of 10 feet through the use of splash blocks or downspout ex tensions. A preferred alternative is to have the roof drains discharge by solid pipe to storm sewers , a detention pond, or other appropriate outfall. Exterior Slab Design and Construction Exterior slabs on-grade, exterior architectural features, and uti lities founded on, or in backfill or the site soils will likely experience some movement due to the volume change of the material. Potential movement could be reduced by: ◼ Minimizing moisture increases in the backfill; ◼ Controlling moisture-density during placement of the backfill; ◼ Using designs which allow vertical movement between the exterior features and adjoining structural elements; and ◼ Placing control joints on relatively close centers. Construction Observation and Testing The earthwork efforts should be monitored under the direction of Terracon. Monitoring should include documentation of adequate removal of vegetation and topsoil, proof rolling, and mitigation of areas delineated by the proof roll to require mitigation. Each lift of compacted fill should be tested, evaluated, and reworked as necessary until approved by Terracon prior to placement of additional lifts. In areas of foundation excavations, the bearing subgrade and exposed conditions at the base of the recommended over-excavation should be evaluated under the direction of Terracon. In the event that unanticipated conditions are encountered, Terracon should prescribe mitigation options. In addition to the documentation of the essential parameters necessary for construction, the continuation of Terracon into the construction phase of the project provides the continuity to maintain Terracon’s evaluation of subsurface conditions, including assessing variations and associated design changes. Geotechnical Engineering Report Fort Collins Nissan and Kia Dealerships ■ Fort Collins, Colorado April 7, 2021 ■ Terracon Project No. 20215013 Responsive ■ Resourceful ■ Reliable 13 SHALLOW FOUNDATIONS If the site has been prepa red in accordance with the requirements noted in Earthwork, the following design parameters are applicable for shallow foundations. Spread Footings - Design Recommendations Description Values Bearing material Properly prepared on-site soil, or new, properly placed engineered fill.1 Maximum net allowable bearing pressure2 3,000 psf Minimum foundation dimensions Columns: 30 inches Continuous: 18 inches Lateral earth pressure coefficients3 Active, Ka = 0.21 Passive, Kp = 4.8 At-rest, Ko = 0.34 Sliding coefficient3 µ = 0.70 Moist soil unit weight ɣ = 125 pcf Minimum embedment depth below finished grade 4 30 inches Estimated total movement 5 About 1 inch Estimated differential movement 5 About ½ to ¾ of total movement 1. Based on the conceptual plans, we understand the buildings are planned for areas where significant fills are not anticipated. The Shallow Foundation parameters in this table are for structures to be placed on native bedrock and do not apply if buildings are placed on fills greater than 12 inches thick. 2. The recommended maximum net allowable bearing pressure assumes any unsuitable fill or soft/loose soils, if encountered, will be over-excavated and replaced with properly compacted engineered fill. The design bearing pressure applies to a dead load plus design live load condition. The design bearing pressure may be increased by one-third when considering total loads that include wind or seismic conditions. 3. The lateral earth pressure coefficients and sliding coefficients are ultimate values and do not include a factor of safety. The foundation designer should include the appropriate factors of safety. 4. For frost protection and to reduce the effects of seasonal moisture variations in the subgrade soils. The minimum embedment depth is for perimeter footings beneath unheated areas and i s relative to lowest adjacent finished grade, typically exterior grade. Interior column pads in heated areas should bear at least 12 inches below the adjacent grade (or top of the floor slab) for confinement of the bearing materials and to develop the recommended bearing pressure. 5. The estimated movements presented above are based on the assumption that the maximum footing size is 8 feet for column footings and 2 feet for continuous footings. Larger foundation footprints will likely require reduced net allowable soil bearing pressures to reduce risk for potential settlement. Footings should be proportioned to reduce differential foundation movement. As discussed, total movement resulting from the assumed structural loads is estimated to be on the order of about 1 inch. Additional foundation movements could occur if water from any source infiltrates the foundation soils; therefore, proper drainage should be provided in the final design and during Geotechnical Engineering Report Fort Collins Nissan and Kia Dealerships ■ Fort Collins, Colorado April 7, 2021 ■ Terracon Project No. 20215013 Responsive ■ Resourceful ■ Reliable 14 construction and throughout the life of the structure. Fa ilure to maintain the proper drainage as recommended in the Grading and Drainage section of the Earthwork section of this report will nullify the movement estimates provided above. Spread Footings - Construction Considerations To reduce the potential of “pumping” and softening of the foundation soils at the foundation bearing level and the requirement for corrective work, we suggest the foundation excavation for the buildings be completed remotely with a track-hoe operating outside of the excavation limits. Spread footing construction should only be considered if the estimated foundation movement can be tolerated. Subgrade soils beneath footings should be moisture conditioned and compacted as described in the Earthwork section of this report. The moisture content and compaction of subgrade soils should be maintained until foundation construction. Footings and foundation walls should be reinforced as necessary to reduce the potential for distre ss caused by differential foundation movement. Unstable surfaces will need to be stabilized prior to backfilling excavations and/or constructing the building foundation, floor slab and/or project pavements. The use of angular rock, recycled concrete and/or gravel pushed or “crowded” into the yielding subgrade is considered suitable means of stabilizing the subgrade. The use of geosynthetic materials in conjunction with gravel could also be considered and could be more cost effective. Unstable subgrade conditions should be observed by Terracon to assess the subgrade and provide suitable alternatives for stabilization. Stabilized areas should be proof rolled prior to continuing construction to assess the stability of the subgrade. Foundation excavations sho uld be observed by Terracon. If the soil conditions encountered differ significantly from those presented in this report, supplemental recommendations will be required. SEISMIC CONSIDERATIONS The seismic design requirements for buildings and other structu res are based on Seismic Design Category. Site Classification is required to determine the Seismic Design Category for a structure. The Site Classification is based on the upper 100 feet of the site profile defined by a weighted average value of either shear wave velocity, standard penetration resistance, or undrained shear strength in accordance with Section 20.4 of ASCE 7 and t he International Building Code (IBC). Based on the soil/bedrock properties encountered at the site and as described on the explora tion logs and results, it is our professional opinion that the Seismic Site Classification is C. Subsurface explorations at this site were extended to a maximum depth of 30 feet. The site Geotechnical Engineering Report Fort Collins Nissan and Kia Dealerships ■ Fort Collins, Colorado April 7, 2021 ■ Terracon Project No. 20215013 Responsive ■ Resourceful ■ Reliable 15 properties below the boring depth to 100 feet were estimated based on our experience and knowledge of geologic conditions of the general area. Additional deeper borings or geophysical testing may be performed to confirm the conditions below the current boring depth. FLOOR SLABS A slab-on-grade may be utilized for the inte rior floor system for the proposed buildings provided the native clay soils and/or sandstone bedrock is over-excavated to a depth of at least 12 inches, moisture conditioned, and compacted on -site soils. If the estimated movement cannot be tolerated, a structurally-supported floor system, supported independent of the subgrade materials, is recommended. Subgrade soils beneath interior and exterior slabs and at the base of the over-excavation should be scarified to a depth of at least 10 inches, moisture co nditioned and compacted. The moisture content and compaction of subgrade soils should be maintained until slab construction. Floor System - Design Recommendations Even when bearing on properly prepared soils, movement of the slab -on-grade floor system is possible should the subgrade soils undergo an increase in moisture content. We estimate movement of about 1 inch is possible. If the owner cannot accept the risk of slab movement, a structural floor should be used. If conventional slab-on-grade is utilized, the subgrade soils should be over-excavated and prepared as presented in the Earthwork section of this report. For structural design of concrete slabs-on-grade subjected to point loadings, a modulus of subgrade reaction of 120 pounds per cubic inch (pci) may be used for floors supported on re - compacted existing clay soils at the site. A modulus of 200 pci may be used for floors supported on at least 1 foot of non -expansive, imported granular fill. Additional floor slab design and construction recommendations are as follows: ◼ Positive separations and/or isolation joints should be provided between slabs and all foundations, columns, or utility lines to allow independent movement. ◼ Control joints should be saw-cut in slabs in accordance with ACI Design Manual, Section 302.1R-37 8.3.12 (tooled control joints are not recommended) to control the location and extent of cracking. ◼ Interior utility trench backfill placed beneath slabs should be compacted in accordance with the recommendations presented in the Earthwork section of this report. Geotechnical Engineering Report Fort Collins Nissan and Kia Dealerships ■ Fort Collins, Colorado April 7, 2021 ■ Terracon Project No. 20215013 Responsive ■ Resourceful ■ Reliable 16 ◼ Floor slabs should not be constructed on frozen subgrade. ◼ Other design and construction considerations, as outlined in the ACI Design Manual, Section 302.1R are recommended. Floor Systems - Construction Considerations Movements of slabs-on-grade using the recommendations discussed in previous sections of this report will likely be reduced and tend to be more uniform. The estimates discussed above assume that the other recommendations in this report are followed. Additional movement could occur should the subsurface soils become wetted to significant depths, which could result in potential excessive movement causing uneven floor slabs and severe cracking. This could be due to over watering of landscaping, poor drainage, improperly functioning drain systems, and/or broken utility lines. Therefore, it is imperative that the recommendations presented in this report be followed. PAVEMENTS Pavements – Subgrade Preparation On most project sites, the site grading is accomplished relatively early in the construction phase. Fills are typically placed and compacted in a uniform manner. However, as construction proceeds, the subgrade may be disturbed due to utilit y excavations, construction traffic, desiccation, or rainfall/snow melt. As a result, the pavement subgrade may not be suitable for pavement construction and corrective action will be required. The subgrade should be carefully evaluated at the time of pavement construction for signs of disturbance or instability. We recommend the pavement subgrade be thoroughly proof rolled with a loaded tandem-axle dump truck prior to final grading and paving. All pavement areas should be moisture conditioned and properly compacted to the recommendations in this report immediately prior to paving. Pavements – Design Recommendations Design of new privately-maintained pavements for the project has been based on the procedures described by the National Asphalt Pavement Asso ciations (NAPA) and the American Concrete Institute (ACI). We assumed the following design parameters for NAPA flexible pavement thickness design: ◼ Automobile Parking Areas • Class I - Parking stalls and parking lots for cars and pick -up trucks, with Equivalent Single Axle Load (ESAL) up to 7,000 over 20 years ◼ Main Traffic Corridors Geotechnical Engineering Report Fort Collins Nissan and Kia Dealerships ■ Fort Collins, Colorado April 7, 2021 ■ Terracon Project No. 20215013 Responsive ■ Resourceful ■ Reliable 17 • Class II – Parking lots with a maximum of 10 trucks per day with Equivalent Single Axle Load (ESAL) up to 27,000 over 20 years (Including trash trucks) ◼ Subgrade Soil Characteristics • USCS Classification – SM to CL, classified by NAPA as medium to poor We assumed the following design parameters for ACI rigid pavement thickness design based upon the average daily truck traffic (ADTT): ◼ Automobile Parking Areas • ACI Category A: Automobile parking with an ADTT of 1 over 20 years ◼ Main Traffic Corridors • ACI Category A: Automobile parking area and service lanes with an ADTT of up to 10 over 20 years ◼ Subgrade Soil Characteristics • USCS Classification – SM to CL ◼ Concrete modulus of rupture value of 600 psi We should be contacted to confirm and/or modify the recommendations contained herein if actual traffic volumes differ from the assumed values shown above. Recommended alternatives for flexible and rigid pavements are summarized for e ach traffic area as follows: Traffic Area Alternative Recommended Pavement Thicknesses (Inches) Asphaltic Concrete Surface Aggregate Base Course Portland Cement Concrete Total Automobile Parking (NAPA Class I and ACI Category A) A 4½ - - 4½ B - - 5 5 Main Traffic Corridors (NAPA Class II and ACI Category A) A 4½ 6 - 10½ B - - 6 6 Aggregate base course (if used on the site) should consist of a blend of sand and gravel which meets strict specifications for quality and gradation. Use of materi als meeting Colorado Department of Transportation (CDOT) Class 5 or 6 specifications is recommended for aggregate base course. Aggregate base course should be placed in lifts not exceeding 6 inches and compacted to a minimum of 95 percent of the maximum d ry unit weight as determined by ASTM D698. Geotechnical Engineering Report Fort Collins Nissan and Kia Dealerships ■ Fort Collins, Colorado April 7, 2021 ■ Terracon Project No. 20215013 Responsive ■ Resourceful ■ Reliable 18 Asphaltic concrete should be composed of a mixture of aggregate, filler and additives (if required) and approved bituminous material. The asphalt concrete should conform to approved mix designs stating the Supe rpave properties, optimum asphalt content, job mix formula and recommended mixing and placing temperatures. Aggregate used in asphalt concrete should meet particular gradations. Material meeting CDOT Grading S or SX specifications or equivalent is recommended for asphalt concrete. Mix designs should be submitted prior to construction to verify their adequacy. Asphalt material should be placed in maximum 3 -inch lifts and compacted within a range of 92 to 96 percent of the theoretical maximum (Rice) density (ASTM D2041). Where rigid pavements are used, the concrete should be produced from an approved mix design with the following minimum properties: Properties Value Compressive strength 4,000 psi Cement type Type I or II portland cement Entrained air content (%) 5 to 8 Concrete aggregate ASTM C33 and CDOT section 703 Concrete should be deposited by truck mixers or agitators and placed a maximum of 90 minutes from the time the water is added to the mix. Longitudinal and transverse joints should be provided as needed in concrete pavements for expansion/contraction and isolation per ACI 325. The location and extent of joints should be based upon the final pavement geometry. For areas subject to concentrated and repetitive loading conditions (if a ny) such as dumpster pads, truck delivery docks and ingress/egress aprons, we recommend using a portland cement concrete pavement with a thickness of at least 6 inches underlain by at least 4 inches of granular base. Prior to placement of the granular base, the areas should be thoroughly proof rolled. For dumpster pads, the concrete pavement area should be large enough to support the container and tipping axle of the refuse truck. Pavement performance is affected by its surroundings. In addition to providing preventive maintenance, the civil engineer should consider the following recommendations in the design and layout of pavements: ■ Site grades should slope a minimum of 2 percent away from the pavements; ■ The subgrade and the pavement surface have a minimum 2 percent slope to promote proper surface drainage; ■ Consider appropriate edge drainage and pavement under drain systems; ■ Install pavement drainage surrounding areas anticipated for frequent wetting; ■ Install joint sealant and seal cracks immediately; Geotechnical Engineering Report Fort Collins Nissan and Kia Dealerships ■ Fort Collins, Colorado April 7, 2021 ■ Terracon Project No. 20215013 Responsive ■ Resourceful ■ Reliable 19 ■ Seal all landscaped areas in, or adjacent to pavements to reduce moisture migration to subgrade soils; and ■ Placing compacted, low permeability backfill against the exterior side of curb and gutter. Pavements – Construction Considerations Openings in pavement, such as landscape islands, are sources for water infiltration into surrounding pavements. Water collects in the islands and migrates into the surrounding subgrade soils thereby degrading support of the pavement. This is especially applicable for islands with raised concrete curbs, irrigated foliage, and low permeability near -surface soils. The civil design for the pavements with these conditions should include features to restrict or to collect and discharge excess water from the islands. Examples of fe atures are edge drains connected to the storm water collection system or other suitable outlet and impermeable barriers preventing lateral migration of water such as a cutoff wall installed to a depth below the pavement structure. Pavements – Maintenance Preventative maintenance should be planned and provided for an ongoing pavement management program in order to enhance future pavement performance. Preventive maintenance consists of both localized maintenance (e.g. crack and joint sealing and patching) and global maintenance (e.g. surface sealing). Preventative maintenance is usually the first priority when implementing a planned pavement maintenance program and provides the highest return on investment for pavements. CORROSIVITY At the time this report was prepared, the laboratory testing for water-soluble sulfates had not been completed. We will submit a supplemental section with the testing results and recommendations once the testing has been completed. GENERAL COMMENTS Our analysis and opinions are based upon our understanding of the project, the geotechnical conditions in the area, and the data obtained from our site exploration. Natural variations will occur between exploration point locations or due to the modifying effec ts of construction or weather. The nature and extent of such variations may not become evident unti l during or after construction. Terracon should be retained as the Geotechnical Engineer, where noted in th is report, to provide observation and testing services during pertinent construction phases. If variations appear, we can provide further evaluation and supplemental recommendations. If variations are noted in the absence of our observation and testing services on -site, we should be immediately notified so that we can provide evaluation and supplemental recommendations. Geotechnical Engineering Report Fort Collins Nissan and Kia Dealerships ■ Fort Collins, Colorado April 7, 2021 ■ Terracon Project No. 20215013 Responsive ■ Resourceful ■ Reliable 20 Our Scope of Services does not include either specifically or by implication any environmental or biological (e.g., mold, fungi, bacteria) assessment of the site or identification or prevention of pollutants, hazardous materials or conditions. If the owner is concerned about the potential for such contamination or pollution, other studies should be undertaken. Our services and any correspondence or collaboration through this system are intended for the sole benefit and exclusive use of our client for specific application to the project discussed and are accomplished in accordance with generally accepted geotechnical engineering practices with no third-party beneficiaries intended. Any third-party access to services or correspondence is solely for information purposes to support the services provided by Terracon to our client. Reliance upon the services and any work product is limited to our client, and is not intended for third parties. Any use or reliance of the p rovided information by third parties is done solely at their own risk. No warranties, either express or implied, are intended or made. Site characteristics as provided are for design purposes and not to estimate excavation cost. Any use of our report in that regard is done at the sole risk of the excavating cost estimator as there may be variations on the site that are not apparent in the data that could significantly impact excavation cost. Any parties charged with estimating excavation costs should seek their own site characterization for specific purposes to obtain the specific level of detail necessary for costing. Site safety, and cost estimating including, excavation support, and dewatering requirements/design are the responsibility of others. If changes in the nature, design, or location of the project are planned, our conclusions and recommendations shall not be considered valid unless we review the changes and either verify or modify our conclusions in writing. Responsive ■ Resourceful ■ Reliable ATTACHMENTS Contents: EXPLORATION AND TESTING PROCEDURES SITE LOCATION AND EXPLORATION PLANS EXPLORATION RESULTS SUPPORTING INFORMATION Note: Refer to each individual Attachment for a listing of contents. Geotechnical Engineering Report Fort Collins Nissan and Kia Dealerships ■ Fort Collins, Colorado April 7, 2021 ■ Terracon Project No. 20215013 Responsive ■ Resourceful ■ Reliable EXPLORATION AND TESTING PROCEDURES 1 of 2 EXPLORATION AND TESTING PROCEDURES Field Exploration The field exploration program consist ed of the following: Number of Borings Boring Depth (feet) Location 2 25 to 30 Planned new Nissan building area 2 20 to 25 Planned new Kia building area 4 15 Planned parking/drive area Boring Layout and Elevations: We used handheld GPS equipment to locate borings with an estimated horizontal accuracy of +/-20 feet. A ground surface elevation at each boring location was obtained by Terracon by interpolation from a USGS topographic map. Subsurface Exploration Procedures: We advanced soil borings with a truck-mounted drill rig using continuous-flight, solid -stem augers. Three samples were obtained in the upper 10 feet of each boring and at intervals of 5 feet thereafter. Soil sampling was performed using modified California barrel and standard split -barrel sampling procedures. For the standard split -barrel sampling procedure, a standard 2 -inch outer diameter split-barrel sampling spoon is driven into the ground by a 140 -pound automatic hammer falling a distance of 30 inches. The number of blows required to advance the sampling spoon the last 12 inches of a normal 18-inch penetration is recorded as the Standard Penetration Test (SPT) resistance value. The SPT resistance values, also referred to as N-values, are indicated on the boring logs at the test depths. For the modified California barrel sampling procedure, a 2½-inch outer diameter split-barrel sampling spoon is used for sampling. Modified California barrel sampling procedures are similar to standard split - barrel sampling procedures; however, blow counts are typically recorded for 6 -inch intervals for a total of 12 inches of penetration. The samples will be placed in appropriate containers, taken to our soil laboratory for testing, and classified by a geotechnical engineer. In addition, we observed and recorded groundwater levels during drilling observations. No provisions were made to obtain delayed groundwater measurements. Our exploration team prepared field boring logs as part of standard drilling operations including sampling depths, penetration distances, and other relevant sampling information . Field logs included visual classifications of materials encountered during drilling, and our interpretation of subsurface conditions between samples. Final boring logs, prepared from field logs, represent the geotechnical engineer's interpretation, and i nclude modifications based on observations and laboratory test results. Geotechnical Engineering Report Fort Collins Nissan and Kia Dealerships ■ Fort Collins, Colorado April 7, 2021 ■ Terracon Project No. 20215013 Responsive ■ Resourceful ■ Reliable EXPLORATION AND TESTING PROCEDURES 2 of 2 Property Disturbance: Borings completed in the existing field were b ackfilled borings with auger cuttings after completion. Borings completed in the existing parking area were backfil led with a mixture of auger cuttings and bentonite chips and patched with concrete to match existing surfaces. Our services did not include repair of the site beyond backfilling our boreholes, and patching existing pavements/surfaces. Excess auger cuttings were dispersed in the general vicinity of the boreholes. Because backfill material often settles below the surface after a period, we recommend checking boreholes periodically and backfilling, if necessary. We can provide this service, at your request. Laboratory Testing The project engineer reviewed field dat a and assigned various laboratory tests to better understand the engineering properties of various soil and bedrock strata. Laboratory testing was conducted in general accordance with applicable or other locally recognized standards. Procedural standards noted in this report are for reference to methodology in general. In some cases, variations to methods are applied as a result of local practice or professional judgement. Testing was performed under the direction of a geotechnical engineer and included the following: ■ Visual classification ■ Moisture content ■ Dry density ■ Atterberg limits ■ Grain-size analysis ■ One-dimensional swell ■ Water-soluble sulfates Our laboratory testing program includes examin ation of soil samples by an engineer. Based on the material’s texture and plasticity, we described and classified soil samples in accordance with the Unified Soil Classification System (USCS). Soil and bedrock samples obtained during our field work will be disposed of after laboratory testing is complete unless a specific request is made to temporarily store the samples for a longer period of time. Bedrock samples obtained had rock classification conducted using locally accepted practices for engineering purposes. Boring log rock classification is determined using the Description of Rock Properties. Responsive ■ Resourceful ■ Reliable SITE LOCATION AND EXPLORATION PLANS Contents: Site Location Plan Exploration Plan Note: All attachments are one page unless noted above. SITE LOCATION Fort Collins Nissan and Kia Dealerships ■ Fort Collins, Colorado April 7, 2021 ■ Terracon Project No. 20215013 Note to Preparer: This is a large table with outside borders. Just click inside the ta ble above this text box, then paste your GIS Toolbox image. When paragraph markers are turned on you may notice a line of hidden text above and outside the table – please leave that alone. Limit editing to inside the table. The line at the bottom about the general location is a separate table line. You can edit it as desired, but try to keep to a single line of text to avoid reformatting the page. SITE LOCA TION DIAGRAM IS FOR GENERAL LOCATION ONLY, AND IS NOT INTENDED FOR CONSTRUCTION PURPOSES MAP PROVIDED BY MICROSOFT BING MAPS EXPLORATION PLAN Fort Collins Nissan and Kia Dealerships ■ Fort Collins, Colorado April 7, 2021 ■ Terracon Project No. 20215013 Note to Preparer: This is a large table with outside borders. Just click inside the table above this text box, then paste your GIS Toolbox image. When paragraph markers are turned on you may notice a line of hidden text above and outside the table – please leave that alone. Limit editing to inside the table . The line at the bottom about the general location is a separate table line. You can edit it as desired, but try to keep to a single line of text to avoid reformatting the page. EXPLORATION P LAN DIAGRAM IS FOR GENERAL LOCATION ONLY, AND IS NOT INTENDED FOR CONSTRUCTION PURPOSES MAP PROVIDED BY MICROSOFT BING MAPS EXPLORATION RESULTS Contents: GeoModel Boring Logs (8 pages) Atterberg Limits Grain Size Distribution (2 pages) Consolidation/Swell Note: All attachments are one page unless noted above. 4,980 4,985 4,990 4,995 5,000 5,005 5,010 5,015 5,020 5,025 ELEVATION(MSL)(feet)Fort Collins Nissan and Kia Dealerships Fort Collins, CO Terracon Project No. 20215013 Layering shown on this figure has been developed by the geotechnical engineer for purposes of modeling the subsurface conditions as required for the subsequent geotechnical engineering for this project. Numbers adjacent to soil column indicate depth below ground surface. NOTES: B-1B-2 B-3 B-4P-1 P-2 P-3 P-4 GEOMODEL This is not a cross section. This is intended to display the Geotechnical Model only. See individual logs for more detailed conditions. Groundwater levels are temporal. The levels shown are representative of the date and time of our exploration. Significant changes are possible over time. Water levels shown are as measured during and/or after drilling. In some cases, boring advancement methods mask the presence/absence of groundwater. See individual logs for details. First Water Observation LEGEND Concrete Aggregate Base Course Sandy Lean Clay Bedrock Vegetative Layer Lean Clay with Sand Weathered Rock Model Layer Layer Name General Description Lean clay with sand to sandy lean clay, brown to light brown,1 stiff to very stiff. Sandstone to siltstone bedrock with trace amounts of clay, cemented sandstone lenses throughout, light brown to tan with orange and gray, hard to very hard. 2 LEAN CLAY BEDROCK 2 24.3 1 214 1 19.2 1 2 2 24.2 1 2 1 29.2 1 2 3 14.4 1 2 2.5 14.4 1 2 1 14.3 1 2 2.5 14.3 1 2 50/5" 50/2" 50/2" 50/3" 50/2" 50/3" 38 13.0 9.7 13.0 17.0 13.0 14.1 118 95 121 NP CONCRETE, approximately 3 inches AGGREGATE BASE COURSE, approximately 2 inches SANDY LEAN CLAY, brown to light brown SANDSTONE/SILTSTONE (SM), with cemented sandstone lenses, light brown to tan, hard to very hard gray brown gray Boring Terminated at 24.3 Feet 0.3 0.4 2.0 24.3 5023.5 5023.5 5022 4999.5 Hammer Type: AutomaticStratification lines are approximate. In-situ, the transition may be gradual.THISBORINGLOGISNOTVALIDIFSEPARATEDFROMORIGINALREPORT.GEOSMARTLOG-NOWELL20215013FORTCOLLINSNISS.GPJTERRACON_DATATEMPLATE.GDT4/8/21WATERLEVELOBSERVATIONSDEPTH(Ft.)5 10 15 20 FIELDTESTRESULTSSWELL/LOAD(%/psf)PERCENTFINESWATERCONTENT(%)DRYUNITWEIGHT(pcf)ATTERBERG LIMITS LL-PL-PI LOCATION See Exploration Plan Latitude: 40.5062° Longitude: -105.0784°GRAPHICLOGMODELLAYERDEPTH ELEVATION (Ft.) Surface Elev.: 5024 (Ft.) Page 1 of 1 Advancement Method: 4-inch diameter, solid-stem augers Abandonment Method: Boring backfilled with a mixture of cuttings and bentonite chips and patched with concrete Notes: Project No.: 20215013 Drill Rig: CME-55 BORING LOG NO. B-1 TCC CorporationCLIENT: Windsor, CO Driller: Drilling Engineers, Inc. Boring Completed: 03-30-2021 PROJECT: Fort Collins Nissan and Kia Dealerships Elevations were interpolated from USGS topographic maps See Exploration and Testing Procedures for a description of field and laboratory procedures used and additional data (If any). See Supporting Information for explanation of symbols and abbreviations. West of South College Avenue and Crestridge Drive Fort Collins, CO SITE: Boring Started: 03-30-2021 1901 Sharp Point Dr Ste C Fort Collins, CO 14' while drilling Boring backfilled immediately upon completion WATER LEVEL OBSERVATIONS 1 2 SAMPLETYPE 21-50/1" 50/5" Sample fell apart upon extraction 50/2" 50/2" 50/2" 2915.0 11.4 11.6 11.6 11.2 114 NP CONCRETE, approximately 4 inches AGGREGATE BASE COURSE, approximately 2 inches SANDY LEAN CLAY, brown to light brown SANDSTONE/SILTSTONE (SM), olive to tan/light brown with white and orange, hard to very hard light brown to olive brown gray Boring Terminated at 19.2 Feet 0.4 0.5 1.0 19.2 5022.5 5022.5 5022 5004 Hammer Type: AutomaticStratification lines are approximate. In-situ, the transition may be gradual.THISBORINGLOGISNOTVALIDIFSEPARATEDFROMORIGINALREPORT.GEOSMARTLOG-NOWELL20215013FORTCOLLINSNISS.GPJTERRACON_DATATEMPLATE.GDT4/8/21WATERLEVELOBSERVATIONSSurface Elev.: 5023 (Ft.) Page 1 of 1 Advancement Method: 4-inch diameter, solid-stem augers Abandonment Method: Boring backfilled with a mixture of cuttings and bentonite chips and patched with concrete Notes: Project No.: 20215013 Drill Rig: CME-55 BORING LOG NO. B-2 TCC CorporationCLIENT: Windsor, CO Driller: Drilling Engineers, Inc. Boring Completed: 03-30-2021 PROJECT: Fort Collins Nissan and Kia Dealerships Elevations were interpolated from USGS topographic maps See Exploration and Testing Procedures for a description of field and laboratory procedures used and additional data (If any). See Supporting Information for explanation of symbols and abbreviations. West of South College Avenue and Crestridge Drive Fort Collins, CO SITE: Boring Started: 03-30-2021 1901 Sharp Point Dr Ste C Fort Collins, CO No free water observed while drilling DEPTH(Ft.)5 10 15 FIELDTESTRESULTSSWELL/LOAD(%/psf)PERCENTFINESWATERCONTENT(%)DRYUNITWEIGHT(pcf)ATTERBERG LIMITS LL-PL-PI LOCATION See Exploration Plan Latitude: 40.5060° Longitude: -105.0779°GRAPHICLOGMODELLAYERDEPTH ELEVATION (Ft.) WATER LEVEL OBSERVATIONS 1 2 SAMPLETYPE 50/5" Sample fell apart upon extraction 50/1" 50/3" 50/3" 50/2" 50/2" 22 6.0 6.0 10.7 12.1 11.6 12.4 106 118 NP SANDY LEAN CLAY, brown to light brown SANDSTONE/SILTSTONE, with cemented sandstone lenses, light brown to red brown with orange brown and white, hard to very hard light brown to tan with gray and dark gray Boring Terminated at 24.2 Feet 2.0 24.2 5020 4998 Hammer Type: AutomaticStratification lines are approximate. In-situ, the transition may be gradual.THISBORINGLOGISNOTVALIDIFSEPARATEDFROMORIGINALREPORT.GEOSMARTLOG-NOWELL20215013FORTCOLLINSNISS.GPJTERRACON_DATATEMPLATE.GDT4/8/21WATERLEVELOBSERVATIONSDEPTH(Ft.)5 10 15 20 FIELDTESTRESULTSSWELL/LOAD(%/psf)PERCENTFINESWATERCONTENT(%)DRYUNITWEIGHT(pcf)ATTERBERG LIMITS LL-PL-PI LOCATION See Exploration Plan Latitude: 40.5071° Longitude: -105.0781°GRAPHICLOGMODELLAYERDEPTH ELEVATION (Ft.) Surface Elev.: 5022 (Ft.) Page 1 of 1 Advancement Method: 4-inch diameter, solid-stem augers Abandonment Method: Boring backfilled with auger cuttings Notes: Project No.: 20215013 Drill Rig: CME-55 BORING LOG NO. B-3 TCC CorporationCLIENT: Windsor, CO Driller: Drilling Engineers, Inc. Boring Completed: 03-30-2021 PROJECT: Fort Collins Nissan and Kia Dealerships Elevations were interpolated from USGS topographic maps See Exploration and Testing Procedures for a description of field and laboratory procedures used and additional data (If any). See Supporting Information for explanation of symbols and abbreviations. West of South College Avenue and Crestridge Drive Fort Collins, CO SITE: Boring Started: 03-30-2021 1901 Sharp Point Dr Ste C Fort Collins, CO No free water observed while drilling WATER LEVEL OBSERVATIONS 1 2 SAMPLETYPE 13-29-45 N=74 50/5" Sample fell apart upon extraction 50/2" 50/2" Sample fell apart upon extraction 50/3" 50/2" 50/2" 466.2 6.3 10.0 8.5 11.5 11.4 11.9 NP NATIVE GRASSES AND WEEDS, with silty, clayey sand, brown to dark brown SANDY LEAN CLAY, brown to light brown SANDSTONE/SILTSTONE (SM), light brown to tan, hard to very hard trace organics with gray Boring Terminated at 29.2 Feet 0.5 1.0 29.2 5019.5 5019 4991 Hammer Type: AutomaticStratification lines are approximate. In-situ, the transition may be gradual.THISBORINGLOGISNOTVALIDIFSEPARATEDFROMORIGINALREPORT.GEOSMARTLOG-NOWELL20215013FORTCOLLINSNISS.GPJTERRACON_DATATEMPLATE.GDT4/8/21WATERLEVELOBSERVATIONSDEPTH(Ft.)5 10 15 20 25 FIELDTESTRESULTSSWELL/LOAD(%/psf)PERCENTFINESWATERCONTENT(%)DRYUNITWEIGHT(pcf)ATTERBERG LIMITS LL-PL-PI LOCATION See Exploration Plan Latitude: 40.5074° Longitude: -105.0788°GRAPHICLOGMODELLAYERDEPTH ELEVATION (Ft.) Surface Elev.: 5020 (Ft.) Page 1 of 1 Advancement Method: 4-inch diameter, solid-stem augers Abandonment Method: Boring backfilled with auger cuttings Notes: Project No.: 20215013 Drill Rig: CME-55 BORING LOG NO. B-4 TCC CorporationCLIENT: Windsor, CO Driller: Drilling Engineers, Inc. Boring Completed: 03-30-2021 PROJECT: Fort Collins Nissan and Kia Dealerships Elevations were interpolated from USGS topographic maps See Exploration and Testing Procedures for a description of field and laboratory procedures used and additional data (If any). See Supporting Information for explanation of symbols and abbreviations. West of South College Avenue and Crestridge Drive Fort Collins, CO SITE: Boring Started: 03-30-2021 1901 Sharp Point Dr Ste C Fort Collins, CO No free water observed while drilling WATER LEVEL OBSERVATIONS 1 2 SAMPLETYPE 12-21 15-27-39 N=66 50/6" Sample fell apart upon extraction 50/5" +2.3/150 819.9 9.9 11.8 12.0 95 32-17-15 NATIVE GRASSES AND WEEDS, with silty, clayey sand, brown to dark brown LEAN CLAY WITH SAND, trace organics, brown, very stiff WEATHERED SANDSTONE, light brown, weathered to firm SANDSTONE, light brown to tan, hard to very hard Boring Terminated at 14.4 Feet 0.5 3.0 5.0 14.4 5019.5 5017 5015 5005.5 Hammer Type: AutomaticStratification lines are approximate. In-situ, the transition may be gradual.THISBORINGLOGISNOTVALIDIFSEPARATEDFROMORIGINALREPORT.GEOSMARTLOG-NOWELL20215013FORTCOLLINSNISS.GPJTERRACON_DATATEMPLATE.GDT4/8/21WATERLEVELOBSERVATIONSDEPTH(Ft.)5 10 FIELDTESTRESULTSSWELL/LOAD(%/psf)PERCENTFINESWATERCONTENT(%)DRYUNITWEIGHT(pcf)ATTERBERG LIMITS LL-PL-PI LOCATION See Exploration Plan Latitude: 40.5071° Longitude: -105.0802°GRAPHICLOGMODELLAYERDEPTH ELEVATION (Ft.) Surface Elev.: 5020 (Ft.) Page 1 of 1 Advancement Method: 4-inch diameter, solid-stem augers Abandonment Method: Boring backfilled with auger cuttings Notes: Project No.: 20215013 Drill Rig: CME-55 BORING LOG NO. P-1 TCC CorporationCLIENT: Windsor, CO Driller: Drilling Engineers, Inc. Boring Completed: 03-30-2021 PROJECT: Fort Collins Nissan and Kia Dealerships Elevations were interpolated from USGS topographic maps See Exploration and Testing Procedures for a description of field and laboratory procedures used and additional data (If any). See Supporting Information for explanation of symbols and abbreviations. West of South College Avenue and Crestridge Drive Fort Collins, CO SITE: Boring Started: 03-30-2021 1901 Sharp Point Dr Ste C Fort Collins, CO No free water observed while drilling WATER LEVEL OBSERVATIONS 1 2 SAMPLETYPE 25-50/4" 50/6" 50/3" Sample fell apart upon extraction 50/5" 55 14.3 13.9 13.3 14.1 119 NP NATIVE GRASSES AND WEEDS, with silty, clayey sand, brown to dark brown SANDY LEAN CLAY, brown to light brown, very stiff SILTSTONE/SANDSTONE (ML), with cemented sandstone, light brown to tan, hard to very hard with gray Boring Terminated at 14.4 Feet 0.5 2.5 14.4 4996.5 4994.5 4982.5 Hammer Type: AutomaticStratification lines are approximate. In-situ, the transition may be gradual.THISBORINGLOGISNOTVALIDIFSEPARATEDFROMORIGINALREPORT.GEOSMARTLOG-NOWELL20215013FORTCOLLINSNISS.GPJTERRACON_DATATEMPLATE.GDT4/8/21WATERLEVELOBSERVATIONSDEPTH(Ft.)5 10 FIELDTESTRESULTSSWELL/LOAD(%/psf)PERCENTFINESWATERCONTENT(%)DRYUNITWEIGHT(pcf)ATTERBERG LIMITS LL-PL-PI LOCATION See Exploration Plan Latitude: 40.5079° Longitude: -105.0789°GRAPHICLOGMODELLAYERDEPTH ELEVATION (Ft.) Surface Elev.: 4997 (Ft.) Page 1 of 1 Advancement Method: 4-inch diameter, solid-stem augers Abandonment Method: Boring backfilled with auger cuttings Notes: Project No.: 20215013 Drill Rig: CME-55 BORING LOG NO. P-2 TCC CorporationCLIENT: Windsor, CO Driller: Drilling Engineers, Inc. Boring Completed: 03-30-2021 PROJECT: Fort Collins Nissan and Kia Dealerships Elevations were interpolated from USGS topographic maps See Exploration and Testing Procedures for a description of field and laboratory procedures used and additional data (If any). See Supporting Information for explanation of symbols and abbreviations. West of South College Avenue and Crestridge Drive Fort Collins, CO SITE: Boring Started: 03-30-2021 1901 Sharp Point Dr Ste C Fort Collins, CO No free water observed while drilling WATER LEVEL OBSERVATIONS 1 2 SAMPLETYPE 50/1" Sample fell apart upon extraction 50/3" 50/2" Sample fel apart upon extraction 50/3" 29 8.0 12.8 11.2 12.8 NP NATIVE GRASSES AND WEEDS, with silty, clayey sand, brown to dark brown SANDY LEAN CLAY, brown to light brown, very stiff SILTSTONE/SANDSTONE (GM), with cemented sandstone lenses, light brown to tan, hard to very hard gray Boring Terminated at 14.3 Feet 0.5 1.0 14.3 5005.5 5005 4991.5 Hammer Type: AutomaticStratification lines are approximate. In-situ, the transition may be gradual.THISBORINGLOGISNOTVALIDIFSEPARATEDFROMORIGINALREPORT.GEOSMARTLOG-NOWELL20215013FORTCOLLINSNISS.GPJTERRACON_DATATEMPLATE.GDT4/8/21WATERLEVELOBSERVATIONSDEPTH(Ft.)5 10 FIELDTESTRESULTSSWELL/LOAD(%/psf)PERCENTFINESWATERCONTENT(%)DRYUNITWEIGHT(pcf)ATTERBERG LIMITS LL-PL-PI LOCATION See Exploration Plan Latitude: 40.5083° Longitude: -105.0782°GRAPHICLOGMODELLAYERDEPTH ELEVATION (Ft.) Surface Elev.: 5006 (Ft.) Page 1 of 1 Advancement Method: 4-inch diameter, solid-stem augers Abandonment Method: Boring backfilled with auger cuttings Notes: Project No.: 20215013 Drill Rig: CME-55 BORING LOG NO. P-3 TCC CorporationCLIENT: Windsor, CO Driller: Drilling Engineers, Inc. Boring Completed: 03-30-2021 PROJECT: Fort Collins Nissan and Kia Dealerships Elevations were interpolated from USGS topographic maps See Exploration and Testing Procedures for a description of field and laboratory procedures used and additional data (If any). See Supporting Information for explanation of symbols and abbreviations. West of South College Avenue and Crestridge Drive Fort Collins, CO SITE: Boring Started: 03-30-2021 1901 Sharp Point Dr Ste C Fort Collins, CO No free water observed while drilling WATER LEVEL OBSERVATIONS 1 2 SAMPLETYPE 21-50/5" Sample fell apart upon extraction 50/5" 50/3" Sample fell apart upon extraction 50/3" 35 5.7 6.8 9.1 9.2 NP NATIVE GRASSES AND WEEDS, with silty, clayey sand, brown to dark brown SANDY LEAN CLAY, brown to light brown, very stiff SANDSTONE/SILTSTONE (SM), trace clay and cemented sandstone lenses, light brown to tan, hard to very hard Boring Terminated at 14.3 Feet 0.5 2.5 14.3 5021.5 5019.5 5007.5 Hammer Type: AutomaticStratification lines are approximate. In-situ, the transition may be gradual.THISBORINGLOGISNOTVALIDIFSEPARATEDFROMORIGINALREPORT.GEOSMARTLOG-NOWELL20215013FORTCOLLINSNISS.GPJTERRACON_DATATEMPLATE.GDT4/8/21WATERLEVELOBSERVATIONSDEPTH(Ft.)5 10 FIELDTESTRESULTSSWELL/LOAD(%/psf)PERCENTFINESWATERCONTENT(%)DRYUNITWEIGHT(pcf)ATTERBERG LIMITS LL-PL-PI LOCATION See Exploration Plan Latitude: 40.5077° Longitude: -105.0779°GRAPHICLOGMODELLAYERDEPTH ELEVATION (Ft.) Surface Elev.: 5022 (Ft.) Page 1 of 1 Advancement Method: 4-inch diameter, solid-stem augers Abandonment Method: Boring backfilled with auger cuttings Notes: Project No.: 20215013 Drill Rig: CME-55 BORING LOG NO. P-4 TCC CorporationCLIENT: Windsor, CO Driller: Drilling Engineers, Inc. Boring Completed: 03-30-2021 PROJECT: Fort Collins Nissan and Kia Dealerships Elevations were interpolated from USGS topographic maps See Exploration and Testing Procedures for a description of field and laboratory procedures used and additional data (If any). See Supporting Information for explanation of symbols and abbreviations. West of South College Avenue and Crestridge Drive Fort Collins, CO SITE: Boring Started: 03-30-2021 1901 Sharp Point Dr Ste C Fort Collins, CO No free water observed while drilling WATER LEVEL OBSERVATIONS 1 2 SAMPLETYPE 0 10 20 30 40 50 60 0 20 40 60 80 100CHorOHCLorOLML or OL MH or OH"U"Line"A "LineATTERBERG LIMITS RESULTS ASTM D4318 P L A S T I C I T Y I N D E X LIQUID LIMIT PROJECT NUMBER: 20215013 SITE: West of South College Avenue and Crestridge Drive Fort Collins, CO PROJECT: Fort Collins Nissan and Kia Dealerships CLIENT: TCC Corporation Windsor, CO 1901 Sharp Point Dr Ste C Fort Collins, CO LABORATORYTESTSARENOTVALIDIFSEPARATEDFROMORIGINALREPORT.ATTERBERGLIMITS20215013FORTCOLLINSNISS.GPJTERRACON_DATATEMPLATE.GDT4/7/21NP NP NP NP 32 NP NP NP NP NP NP NP 17 NP NP NP NP NP NP NP 15 NP NP NP PIPLLLBoring ID Depth B-1 B-2 B-3 B-4 P-1 P-2 P-3 P-4 38.1 28.7 22.2 45.7 81.2 54.8 28.8 35.3 Fines 9 - 9.2 2 - 2.7 9 - 9.3 2 - 3.5 2 - 3 4 - 4.5 4 - 4.3 9 - 9.3 SM SM GM SM CL ML GM SM SANDSTONE/SILTSTONE with CEMENTED LENSES SANDSTONE/SILTSTONE SANDSTONE/SILTSTONE with CEMENTED LENSES SANDSTONE/SILTSTONE LEAN CLAY with SAND SILTSTONE/SANDSTONE with CEMENTED LENSES SILTSTONE/SANDSTONE with CEMENTED LENSES SANDSTONE/SILTSTONE with CEMENTED LENSES DescriptionUSCS CL-ML 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 0.0010.010.1110100 30 40 501.5 200681014413/4 1/2 60 GRAIN SIZE IN MILLIMETERSPERCENTFINERBYWEIGHT HYDROMETERU.S. SIEVE OPENING IN INCHES U.S. SIEVE NUMBERS 4 3/8 3 100 14032 GRAIN SIZE DISTRIBUTION ASTM D422 / ASTM C136 6 16 20 PROJECT NUMBER: 20215013 SITE: West of South College Avenue and Crestridge Drive Fort Collins, CO PROJECT: Fort Collins Nissan and Kia Dealerships CLIENT: TCC Corporation Windsor, CO 1901 Sharp Point Dr Ste C Fort Collins, CO LABORATORYTESTSARENOTVALIDIFSEPARATEDFROMORIGINALREPORT.GRAINSIZE:USCS-220215013FORTCOLLINSNISS.GPJTERRACON_DATATEMPLATE.GDT4/7/21mediumcoarsecoarsefine fineCOBBLESGRAVELSAND SILT OR CLAY B-1 B-2 B-3 B-4 P-1 SANDSTONE/SILTSTONE with CEMENTED LENSES (SM) SANDSTONE/SILTSTONE (SM) SANDSTONE/SILTSTONE with CEMENTED LENSES (GM) SANDSTONE/SILTSTONE (SM) LEAN CLAY with SAND (CL) NP NP NP NP 32 NP NP NP NP 15 NP NP NP NP 17 9 - 9.2 2 - 2.7 9 - 9.3 2 - 3.5 2 - 3 13.0 15.0 10.7 6.2 9.9 B-1 B-2 B-3 B-4 P-1 38.1 28.7 22.2 45.7 81.2 9 - 9.2 2 - 2.7 9 - 9.3 2 - 3.5 2 - 3 24.5 4.1 39.8 0.0 0.0 37.5 67.2 38.0 54.2 18.8 37.5 12.5 37.5 9.5 9.5 0.135 0.182 4.601 0.093 0.078 0.096 Boring ID Depth WC (%)LL PL PI Cc Cu %Clay%Fines%Silt%Sand%Gravel Boring ID Depth D100 D60 D30 D10 USCS Classification %Cobbles 0.0 0.0 0.0 0.0 0.0 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 0.0010.010.1110100 30 40 501.5 200681014413/4 1/2 60 GRAIN SIZE IN MILLIMETERSPERCENTFINERBYWEIGHT HYDROMETERU.S. SIEVE OPENING IN INCHES U.S. SIEVE NUMBERS 4 3/8 3 100 14032 GRAIN SIZE DISTRIBUTION ASTM D422 / ASTM C136 6 16 20 PROJECT NUMBER: 20215013 SITE: West of South College Avenue and Crestridge Drive Fort Collins, CO PROJECT: Fort Collins Nissan and Kia Dealerships CLIENT: TCC Corporation Windsor, CO 1901 Sharp Point Dr Ste C Fort Collins, CO LABORATORYTESTSARENOTVALIDIFSEPARATEDFROMORIGINALREPORT.GRAINSIZE:USCS-220215013FORTCOLLINSNISS.GPJTERRACON_DATATEMPLATE.GDT4/7/21mediumcoarsecoarsefine fineCOBBLESGRAVELSAND SILT OR CLAY P-2 P-3 P-4 SILTSTONE/SANDSTONE with CEMENTED LENSES (ML) SILTSTONE/SANDSTONE with CEMENTED LENSES (GM) SANDSTONE/SILTSTONE with CEMENTED LENSES (SM) NP NP NP NP NP NP NP NP NP 4 - 4.5 4 - 4.3 9 - 9.3 13.9 12.8 9.1 P-2 P-3 P-4 54.8 28.8 35.3 4 - 4.5 4 - 4.3 9 - 9.3 7.9 35.6 29.9 37.4 35.6 34.8 25 25 25 0.086 2.802 0.21 0.078 Boring ID Depth WC (%)LL PL PI Cc Cu %Clay%Fines%Silt%Sand%Gravel Boring ID Depth D100 D60 D30 D10 USCS Classification %Cobbles 0.0 0.0 0.0 -10 -8 -6 -4 -2 0 2 4 100 1,000 10,000AXIALSTRAIN,%PRESSURE, psf NOTES: Sample exhibited 2.3 percent swell upon wetting under an applied pressure of 150 psf. SWELL CONSOLIDATION TEST ASTM D4546 PROJECT NUMBER: 20215013 SITE: West of South College Avenue and Crestridge Drive Fort Collins, CO PROJECT: Fort Collins Nissan and Kia Dealerships CLIENT: TCC Corporation Windsor, CO 1901 Sharp Point Dr Ste C Fort Collins, CO LABORATORYTESTSARENOTVALIDIFSEPARATEDFROMORIGINALREPORT.TC_CONSOL_STRAIN-USCS20215013FORTCOLLINSNISS.GPJTERRACON_DATATEMPLATE.GDT4/7/21P-1 LEAN CLAY with SAND(CL)2 - 3 ft 95 9.9 Specimen Identification Classification , pcf WC, % SUPPORTING INFORMATION Contents: General Notes Unified Soil Classification System Description of Rock Properties Note: All attachments are one page unless noted above. Fort Collins Nissan and Kia Dealerships Fort Collins, CO Terracon Project No. 20215013 2,000 to 4,000 Unconfined Compressive Strength Qu, (psf) less than 500 500 to 1,000 1,000 to 2,000 4,000 to 8,000 > 8,000 Modified California Ring Sampler Standard Penetration Test N (HP) (T) (DCP) UC (PID) (OVA) Standard Penetration Test Resistance (Blows/Ft.) Hand Penetrometer Torvane Dynamic Cone Penetrometer Unconfined Compressive Strength Photo-Ionization Detector Organic Vapor Analyzer SAMPLING WATER LEVEL FIELD TESTS GENERAL NOTES DESCRIPTION OF SYMBOLS AND ABBREVIATIONS Water levels indicated on the soil boring logs are the levels measured in the borehole at the times indicated. Groundwater level variations will occur over time. In low permeability soils, accurate determination of groundwater levels is not possible with short term water level observations. Water Initially Encountered Water Level After a Specified Period of Time Water Level After a Specified Period of Time Cave In Encountered Exploration point locations as shown on the Exploration Plan and as noted on the soil boring logs in the form of Latitude and Longitude are approximate. See Exploration and Testing Procedures in the report for the methods used to locate the exploration points for this project. Surface elevation data annotated with +/- indicates that no actual topographical survey was conducted to confirm the surface elevation. Instead, the surface elevation was approximately determined from topographic maps of the area. LOCATION AND ELEVATION NOTES Soil classification as noted on the soil boring logs is based Unified Soil Classification System. Where sufficient laboratory data exist to classify the soils consistent with ASTM D2487 "Classification of Soils for Engineering Purposes" this procedure is used. ASTM D2488 "Description and Identification of Soils (Visual-Manual Procedure)" is also used to classify the soils, particularly where insufficient laboratory data exist to classify the soils in accordance with ASTM D2487. In addition to USCS classification, coarse grained soils are classified on the basis of their in-place relative density, and fine-grained soils are classified on the basis of their consistency. See "Strength Terms" table below for details. The ASTM standards noted above are for reference to methodology in general. In some cases, variations to methods are applied as a result of local practice or professional judgment. DESCRIPTIVE SOIL CLASSIFICATION The soil boring logs contained within this document are intended for application to the project as described in this document. Use of these soil boring logs for any other purpose may not be appropriate. RELEVANCE OF SOIL BORING LOG STRENGTH TERMS 30 - 50 > 50 5 - 9 10 - 18 Descriptive Term (Consistency) 8 - 15 > 30 Ring Sampler Blows/Ft. 10 - 29 > 99 Medium Hard < 3 3 - 4 19 - 42 2 - 4 BEDROCK Standard Penetration or N-Value Blows/Ft. 0 - 3Very Loose Very Soft (More than 50% retained on No. 200 sieve.) Density determined by Standard Penetration Resistance (50% or more passing the No. 200 sieve.) Consistency determined by laboratory shear strength testing, field visual-manual procedures or standard penetration resistance RELATIVE DENSITY OF COARSE-GRAINED SOILS 30 - 49 50 - 79 >79 Descriptive Term (Consistency) Firm < 20 Weathered Hard < 30 30 - 49 50 - 89 90 - 119 > 11915 - 30 Standard Penetration or N-Value Blows/Ft. 0 - 1 4 - 8 Very Hard Ring Sampler Blows/Ft. Ring Sampler Blows/Ft. Soft Medium Stiff Stiff Very Stiff Hard CONSISTENCY OF FINE-GRAINED SOILS Standard Penetration or N-Value Blows/Ft. > 42 Loose Medium Dense Dense Very Dense 7 - 18 19 - 58 Descriptive Term (Density) 0 - 6 4 - 9 59 - 98 _ 20 - 29 UNIFIED SOIL CLASSIFICATION SYSTEM UNIFIED SOI L CLASSI FICATI ON SYSTEM Criteria for Assigning Group Symbols and Group Names Using Laboratory Tests A Soil Classification Group Symbol Group Name B Coarse-Grained Soils: More than 50% retained on No. 200 sieve Gravels: More than 50% of coarse fraction retained on No. 4 sieve Clean Gravels: Less than 5% fines C Cu  4 and 1  Cc  3 E GW Well-graded gravel F Cu  4 and/or [Cc<1 or Cc>3.0] E GP Poorly graded gravel F Gravels with Fines: More than 12% fines C Fines classify as ML or MH GM Silty gravel F, G, H Fines classify as CL or CH GC Clayey gravel F, G, H Sands: 50% or more of coarse fraction passes No. 4 sieve Clean Sands: Less than 5% fines D Cu  6 and 1  Cc  3 E SW Well-graded sand I Cu  6 and/or [Cc<1 or Cc>3.0] E SP Poorly graded sand I Sands with Fines: More than 12% fines D Fines classify as ML or MH SM Silty sand G, H, I Fines classify as CL or CH SC Clayey sand G, H, I Fine-Grained Soils: 50% or more passes the No. 200 sieve Silts and Clays: Liquid limit less than 50 Inorganic: PI  7 and plots on or above “A” line J CL Lean clay K, L, M PI  4 or plots below “A” line J ML Silt K, L, M Organic: Liquid limit - oven dried  0.75 OL Organic clay K, L, M, N Liquid limit - not dried Organic silt K, L, M, O Silts and Clays: Liquid limit 50 or more Inorganic: PI plots on or above “A” line CH Fat clay K, L, M PI plots below “A” line MH Elastic Silt K, L, M Organic: Liquid limit - oven dried  0.75 OH Organic clay K, L, M, P Liquid limit - not dried Organic silt K, L, M, Q Highly organic soils: Primarily organic matter, dark in color, and organic odor PT Peat A Based on the material passing the 3-inch (75-mm) sieve. B If field sample contained cobbles or boulders, or both, add “with cobbles or boulders, or both” to group name. C Gravels with 5 to 12% fines require dual symbols: GW -GM well-graded gravel with silt, GW -GC well-graded gravel with clay, GP-GM poorly graded gravel with silt, GP-GC poorly graded gravel with clay. D Sands with 5 to 12% fines require dual symbols: SW -SM well-graded sand with silt, SW -SC well-graded sand with clay, SP-SM poorly graded sand with silt, SP-SC poorly graded sand with clay. E Cu = D60/D10 Cc = 6010 2 30 DxD )(D F If soil contains  15% sand, add “with sand” to group name. G If fines classify as CL-ML, use dual symbol GC-GM, or SC-SM. H If fines are organic, add “with organic fines” to group name. I If soil contains  15% gravel, add “with gravel” to group name. J If Atterberg limits plot in shaded area, soil is a CL-ML, silty clay. K If soil contains 15 to 29% plus No. 200, add “with sand” or “with gravel,” whichever is predominant. L If soil contains  30% plus No. 200 predominantly sand, add “sandy” to group name. M If soil contains  30% plus No. 200, predominantly gravel, add “gravelly” to group name. N PI  4 and plots on or above “A” line. O PI  4 or plots below “A” line. P PI plots on or above “A” line. Q PI plots below “A” line. DESCRIPTION OF ROCK PROPERTIES ROCK VERSION 1 WEATHERING Term Description Unweathered No visible sign of rock material weathering, perhaps slight discoloration on major discontinuity surfaces. Slightly weathered Discoloration indicates weathering of rock material and discontinuity surfaces. All the rock material may be discolored by weathering and may be somewhat weaker externally than in its fresh condition. Moderately weathered Less than half of the rock material is decomposed and/or disintegrated to a soil. Fresh or discolored rock is present either as a continuous framework or as corestones. Highly weathered More than half of the rock material is decomposed and/or disintegrated to a soil. Fresh or discolored rock is present either as a discontinuous framework or as corestones. Completely weathered All rock material is decomposed and/or disintegrated to soil. The original mass structure is still largely intact. Residual soil All rock material is converted to soil. The mass structure and material fabric are destroyed. There is a large change in volume, but the soil has not been significantly transported. STRENGTH OR HARDNESS Description Field Identification Uniaxial Compressive Strength, psi (MPa) Extremely weak Indented by thumbnail 40-150 (0.3-1) Very weak Crumbles under firm blows with point of geological hammer, can be peeled by a pocket knife 150-700 (1-5) Weak rock Can be peeled by a pocket knife with difficulty, shallow indentations made by firm blow with point of geological hammer 700-4,000 (5-30) Medium strong Cannot be scraped or peeled with a pocket knife, specimen can be fractured with single firm blow of geological hammer 4,000-7,000 (30-50) Strong rock Specimen requires more than one blow of geological hammer to fracture it 7,000-15,000 (50-100) Very strong Specimen requires many blows of geological hammer to fracture it 15,000-36,000 (100-250) Extremely strong Specimen can only be chipped with geological hammer >36,000 (>250) DISCONTINUITY DESCRIPTION Fracture Spacing (Joints, Faults, Other Fractures) Bedding Spacing (May Include Foliation or Banding) Description Spacing Description Spacing Extremely close < ¾ in (<19 mm) Laminated < ½ in (<12 mm) Very close ¾ in – 2-1/2 in (19 - 60 mm) Very thin ½ in – 2 in (12 – 50 mm) Close 2-1/2 in – 8 in (60 – 200 mm) Thin 2 in – 1 ft. (50 – 300 mm) Moderate 8 in – 2 ft. (200 – 600 mm) Medium 1 ft. – 3 ft. (300 – 900 mm) Wide 2 ft. – 6 ft. (600 mm – 2.0 m) Thick 3 ft. – 10 ft. (900 mm – 3 m) Very Wide 6 ft. – 20 ft. (2.0 – 6 m) Massive > 10 ft. (3 m) Discontinuity Orientation (Angle): Measure the angle of discontinuity relative to a plane perpendicular to the longitudinal axis of the core. (For most cases, the core axis is vertical; therefore, the plane perpendicular to the core axis is horizontal.) For example, a horizontal bedding plane would have a 0-degree angle. ROCK QUALITY DESIGNATION (RQD) 1 Description RQD Value (%) Very Poor 0 - 25 Poor 25 – 50 Fair 50 – 75 Good 75 – 90 Excellent 90 - 100 1. The combined length of all sound and intact core segments equal to or greater than 4 inches in length, expressed as a percentage of the total core run length. Reference: U.S. Department of Transportation, Federal Hig hway Administration, Publication No FHWA-NHI-10-034, December 2009 Technical Manual for Design and Construction of Road Tunnels – Civil Elements