Loading...
HomeMy WebLinkAboutREPLAT OF LOT 1, SOUTHMOOR VILLAGE EAST, SECOND FILING - MINOR SUBDIVISION - 105-88 - CORRESPONDENCE - CORRESPONDENCE-CONCEPTUAL REVIEWDevel-Went Services Planning Department Citv of Fort Collins Novcmbcr 22, 1988 Tcrrel Custom Homes c/o Stewart Engineering 214 North Howes Street Fort Collins, CO 80521 Dcar Sirs: For your information, attached is a copy of the Staff's comments concerning Replat of Lot 1 - Southmoor Village East, 2nd Filing into 3 New Lots, which was presented before the Conceptual Review Team on November 21, 1988. The comments are offered informally by Staff to assist you in preparing the detailed components of the project application. Modifications and additions to these comments may be made at the time of formal review of this project. If you should have any questions regarding these comments or the next steps in the review process, please feel free to call me at 221-6750. Sincerely, Ted Shepard 'f Project Planner TS;'bh Attachment xc: Tom Peterson, Director of Planning Mike Herzig, Development Coordinator Jim Faulhaber, Civil Engineer I Project Planner File 300 LaPorte Avenue • P.O. Box 580 • Fort Collins, CO 80522-0580 • (303) 221-6750 CONCEPTUAL REVIE"N S T AFC- COMME�' T MEETING DATE: November 21, 1988 ITEM: Rcplat of Lot 1 Southmoor Village East, Second Filing into 3 new lots APPLICANT: Terrel Custom Homes c/o Stewart Engineering, 214 North Howes, Fort Collins, CO. 80521 LAND USE DATA: Request for a 3 lot subdivision on the east side of Lemay just south of Springwood Drive. Each lot slightly under one acre. Proposed use is single family custom homes. Access would be gained by a common driveway as an access easement. COMMENTS: 1. The City Light. and Power Department has existing power in Lemay Avenue. There is an oval vault to the south and power could be placed in a trench and run to the north. There is a possibility, however, that the large size of the homes may necessitate a new vault. Light and Power will investigate this possibility. 2. The plat should show the existing power pole. This may have to be removed and placed underground. 3. An 8 inch sewer must be installed all the way back to the manhole. A 6 inch sewer is not acceptable. 4. The fire access, as proposed, does not meet code. Please consult with Mr. Warren Jones, Fire Marshal, as to how best to meet the fire access requirements. 5. The sign code allows one "For Sale" sign per lot not to exceed six square feet. The project, as a whole, is allowed one project I.D. sign that would be temporary and requires a permit. 6. Please coordinate with Mr. Glen Schlueter, Stormwater Utility, as to the submittal requirements for the Drainage Report. 7. It would be desirable to save as many existing trees as possible. 8. Please consider widening the private access drive at the intersection in order to allow more room for vehicles turning in both directions. Staff suggests the intersection be a width of 24 feet and then use a length of 50 feet to taper back down to 20 feet as proposed. 9. Use the platting process to dedicate new easements or vacate as necessary.