Loading...
HomeMy WebLinkAboutTIMBER LARK SINGLE-FAMILY DEVELOPMENT - PDP210015 - SUBMITTAL DOCUMENTS - ROUND 1 - UTILITY PLANSOriginal Field Survery: Northern Engineering Project No. 698-004 Date: June 5, 2019 JULY 2021 CONTACT INFORMATION PROJECT TEAM: VICINITY MAP NORTH PROJECT BENCHMARKS: TIMBER LARK RESIDENTIAL PROJECT TEAM: Ripley Design Katy Thompson, PLA, ULI 419 Canyon Avenue Suite 200 Fort Collins, Colorado 80521 (970) 498 -2665 AADT Land Holdings, LLC Alex Aigner 13005 Lowell Boulevard Broomfield, CO 80020 PLANNER/ LANDSCAPE ARCHITECT OWNER/APPLICANT SITE ENGINEER SHEET INDEX A TRACT OF LAND LOCATED IN THE SOUTHEAST QUARTER OF SECTION 7, TOWNSHIP 6 NORTH, RANGE 68 WEST OF THE 6TH P.M., CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO FIELD SURVEY BY: SITE SURVEYOR 1 CS1 COVER SHEET 2 CS2 GENERAL & CONSTRUCTION NOTES 3 EX1 EXISTING CONDITIONS AND DEMOLITION PLAN UTILITY SHEETS 4 OU1 OVERALL UTILITY PLAN 5 - 7 UT1 - UT3 UTILITY PLAN GRADING SHEETS 8 OGR1 OVERALL GRADING PLAN 9 - 11 GR1 - GR3 GRADING PLAN ROADWAY SHEETS 12 R1 STREET E & A PLAN AND PROFILE 13 - 14 R2 - R3 STREET A PLAN AND PROFILE 15 R4 STREET A & CORONA AVENUE PLAN AND PROFILE 16 R5 STREET B PLAN AND PROFILE 17 R6 STREET B & I PLAN AND PROFILE 18 R7 STREET C PLAN AND PROFILE 19 - 20 R8 - R9 GOLDEN WILLOW DRIVE PLAN AND PROFILE 21 R10 STREET G PLAN AND PROFILE 22 - 23 R11 - R12 WEEPING WILLOW DRIVE PLAN AND PROFILE 24 - 25 R13 - R14 RED WILLOW DRIVE PLAN AND PROFILE 26 R15 ALLEY K & L PLAN AND PROFILES 27 R16 ALLEY M & N PLAN AND PROFILE 28 R17 ALLEY O & P PLAN AND PROFILE DRAINAGE SHEETS 29 DR1 DRAINAGE PLAN PRELIMINARY UTILITY PLANS FOR Earth Engineering Consultants, LLC Preliminary Subsurface Exploration Report South Timberline Development Fort Collins, Colorado EEC Project No. 1202034 Date: June 2, 2020 SUBSURFACE EXPLORATION BY: UTILITY CONTACT LIST: * UTILITY COMPANY * This list is provided as a courtesy reference only. Northern Engineering Services assumes no responsibility for the accuracy or completeness of this list. In no way shall this list relinquish the Contractor's responsibility for locating all utilities prior to commencing any construction activity. Please contact the Utility Notification Center of Colorado (UNCC) at 811 for additional information. PHONE NUMBER GAS-----------------Xcel Energy-----------------------------Pat Kreager (970) 225-7840 ELECTRIC--------City of Fort Collins Light & Power--Rob Irish (970) 224-6167 CABLE-------------Comcast----------------------------------Don Kapperman (970) 567-0425 TELECOM.--------CenturyLink-------------------------------William Johnson (970) 377-6401 WATER------------City of Fort Collins Utilities-----------Shane Boyle (970) 221-6339 WASTEWATER--City of Fort Collins Utilities-----------Shane Boyle (970) 221-6339 STORMWATER-City of Fort Collins Utilities-----------Shane Boyle (970) 221-6339 E N G I N E E R N GI EHTRON R N E N G I N E E R N GI EHTRON R N CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R SheetTIMBER LARK RESIDENTIALThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 29 PROJECT LOCATION SOUTH TIMBERLINEEAST TRILBY ROAD City of Fort Collins, CO UTILITY PLAN APPROVAL APPROVED: CITY ENGINEER,APPROVED SHEETS DATE APPROVED: WATER & WASTEWATER UTILITY,APPROVED SHEETS DATE APPROVED: STORMWATER UTILITY,APPROVED SHEETS DATE APPROVED: PARK PLANNING & DEVELOPMENT,APPROVED SHEETS DATE APPROVED: TRAFFIC OPERATIONS,APPROVED SHEETS DATE APPROVED: ENVIRONMENTAL PLANNER,APPROVED SHEETS DATE All changes, addendums, additions, deletions and modifications to these drawings must be approved, in writing, by the Fort Collins-Loveland Water District and the South Fort Collins Sanitation District. District Engineer Date FORT COLLINS - LOVELAND WATER DISTRICT SOUTH FORT COLLINS SANITATION DISTRICT I hereby affirm that these final construction plans were prepared under my direct supervision, in accordance with all applicable City of Fort Collins and State of Colorado standards and statutes, respectively; and that I am fully responsible for the accuracy of all design. revisions, and record conditions that I have noted on these plans. These plans have been reviewed by the City of Fort Collins for concept only. The review does not imply responsibility by the reviewing department, the City of Fort Collins Engineer, or the City of Fort Collins for accuracy and correctness of the calculations. Furthermore, the review does not imply that quantities of items on the plans are the final quantities required. The review shall not be construed for any reason as acceptance of financial responsibility by the City of Fort Collins for additional quantities of items shown that may be required during the construction phase. DISCLAIMER STATEMENT: CERTIFICATION STATEMENT: PROJECT DATUM: NAVD88 CITY OF FORT COLLINS BENCHMARK 2-02 EAST SIDE OF TIMBERLAND ROAD, 1/2 MILE NORTH OF TRILBY ROAD, ON THE MIDDLE CONCRETE PAD TO AN ELECTRIC BOX. ELEVATION: 4964.37 CITY OF FORT COLLINS BENCHMARK 12-13 SOUTHEAST CORNER OF TIMBERLINE RD. AND TRILBY RD., ON A CONCRETE TRAFFIC SIGNAL BASE. ELEVATION: 4926.67 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) = NAVD88 - 3.19' BASIS OF BEARINGS THE EAST LINE OF THE SOUTHEAST QUARTER OF SECTION 7, TOWNSHIP 6 NORTH, RANGE 68 WEST OF THE 6TH P.M. AS BEARING NORTH 00°06'07" EAST CS1 COVER SHEET1 Northern Engineering Services, Inc. Robbie Lauer 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 (970) 221-4158 Northern Engineering Services, Inc. Bob Tessely, PLS 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 (970) 221-4158 ALLEY (PRIVATE)10' TRAVEL LANE20' EOC-TBC 31" DRIVE-OVER CURB & GUTTER10' TRAVEL LANE51' MIN. ROW9' UTIL. ESMT. 9' UTIL. ESMT. RESIDENTIAL LOCAL7' PARKING30' -16' TRAVEL4.5' WALK4.5' WALK6' PKWY MIN. 6' PKWY MIN.7' PARKING1' x 1' CONCRETE EDGE 8' UTIL. ESMT. VARIES 8' UTIL. ESMT. VARIES 6.5' MIN FENCE SETBACK FROM FACE OF WALK ·STREET A ·STREET B ·WEEPING WILLOW DRIVE ·STREET G ·RED WILLOW DRIVE ·STREET I ·CORONA AVENUE ·GOLDEN WILLOW DRIVE 57' ROW9' UTIL. ESMT. 9' UTIL. ESMT. LOCAL CONNECTOR8' PARKING8' PARKING10' TRAVEL LANE6' PKWY MIN. 36' -10' TRAVEL LANE4.5' WALK4.5' WALK30" VERTICAL CURB & GUTTER30" VERTICAL CURB & GUTTER 6' PKWY MIN. ·STREET C ·RED WILLOW DRIVE ·STREET I 30" VERTICAL CURB & GUTTER 30" VERTICAL CURB & GUTTER 53' ROW9' UTIL. ESMT. 9' UTIL. ESMT. RESIDENTIAL LOCAL7' PARKING30' -16' TRAVEL4.5' WALK4.5' WALK7' PKWY MIN. 7' PKWY MIN.7' PARKING6.5' MIN FENCE SETBACK FROM FACE OF WALK DRIVEOVER CURB & GUTTER DRIVEOVER CURB & GUTTER ALLEY (PRIVATE)10' TRAVEL LANE20' EOC-TBC 31" DRIVE-OVER CURB & GUTTER10' TRAVEL LANE1' x 1' CONCRETE EDGE 8' UTIL. ESMT. VARIES 8' UTIL. ESMT. VARIES *IF DRIVEOVER CURB & GUTTER IS USED AN ADDITIONAL 1-FT OF RIGHT-OF-WAY IS ADDED AND PARKWAY INCREASED TO 7-FT ·ALLEY K ·ALLEY M ·ALLEY N ·ALLEY P ·ALLEY O ·ALLEY L 30' TRACT 30' TRACT ·STREET E ·WEEPING WILLOW DRIVE ·RED WILLOW DRIVE ·GOLDEN WILLOW DRIVE SheetTIMBER LARK RESIDENTIALThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 29 GENERAL NOTES 1.All materials, workmanship, and construction of ppublic improvements shall meet or exceed the standards and specifications set forth in the Larimer County Urban Area Street Standards and applicable state and federal regulations. Where there is conflict between these plans and the specifications, or any applicable standards, the most restrictive standard shall apply. All work shall be inspected and approved by the City of Fort Collins. 2.All references to any published standards shall refer to the latest revision of said standard, unless specifically stated otherwise. 3.These public improvement construction plans shall be valid for a period of three years from the date of approval by the City of Fort Collins Engineer. Use of these plans after the expiration date will require a new review and approval process by the City of Fort Collins prior to commencement of any work shown in these plans. 4.The engineer who has prepared these plans, by execution and/or seal hereof, does hereby affirm responsibility to the City of Fort Collins, as beneficiary of said engineer's work, for any errors and omissions contained in these plans, and approval of these plans by the City of Fort Collins Engineer shall not relieve the engineer who has prepared these plans of all such responsibility. Further, to the extent permitted by law, the engineer hereby agrees to hold harmless and indemnify the City of Fort Collins, and its officers and employees, from and against all liabilities, claims, and demands which may arise from any errors and omissions contained in these plans. 5.All storm sewer construction, as well as power and other "dry" utility installations, shall conform to the City of Fort Collins standards and specifications current at the date of approval of the plans by the City of Fort Collins Engineer. 6.The type, size, location and number of all known underground utilities are approximate when shown on the drawings. It shall be the responsibility of the Developer to verify the existence and location of all underground utilities along the route of the work before commencing new construction. The Developer shall be responsible for unknown underground utilities. 7.The Developer shall contact the Utility Notification Center of Colorado (UNCC) at 1-800-922-1987, at least 2 working days prior to beginning excavation or grading, to have all registered utility locations marked. Other unregistered utility entities (i.e. ditch / irrigation company) are to be located by contacting the respective representative. Utility service laterals are also to be located prior to beginning excavation or grading. It shall be the responsibility of the Developer to relocate all existing utilities that conflict with the proposed improvements shown on these plans. 8.The Developer shall be responsible for protecting all utilities during construction and for coordinating with the appropriate utility company for any utility crossings required. 9.If a conflict exists between existing and proposed utilities and/or a design modification is required, the Developer shall coordinate with the engineer to modify the design. Design modification(s) must be approved by the City of Fort Collins prior to beginning construction. 10.The Developer shall coordinate and cooperate with the City of Fort Collins, and all utility companies involved, to assure that the work is accomplished in a timely fashion and with a minimum disruption of service. The Developer shall be responsible for contacting, in advance, all parties affected by any disruption of any utility service as well as the utility companies. 11.No work may commence within any public storm water, sanitary sewer or potable water system until the Developer notifies the utility provider. Notification shall be a minimum of 2 working days prior to commencement of any work. At the discretion of the water utility provider, a pre-construction meeting may be required prior to commencement of any work. 12.The Developer shall sequence installation of utilities in such a manner as to minimize potential utility conflicts. In general, storm sewer and sanitary sewer should be constructed prior to installation of the water lines and dry utilities. 13.The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the Water Utility. 14.A State Construction Dewatering Wastewater Discharge Permit is required if dewatering is required in order to install utilities or if water is discharged into a storm sewer, channel, irrigation ditch or any waters of the United States. 15.The Developer shall comply with all terms and conditions of the Colorado Permit for Storm Water Discharge (Contact Colorado Department of Health, Water Quality Control Division, (303) 692-3590), the Storm Water Management Plan, and the Erosion Control Plan. 16.The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 17.Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must be submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. 18.The City of Fort Collins shall not be responsible for any damages or injuries sustained in this Development as a result of groundwater seepage, whether resulting from groundwater flooding, structural damage or other damage unless such damage or injuries are sustained as a result of the City of Fort Collins failure to properly maintain its water, wastewater, and/or storm drainage facilities in the development. 19.All recommendations of the Preliminary Drainage Report for Timber Lark, dated July 9, 2021 by Northern Engineering Services, Inc., shall be followed and implemented. 20.Temporary erosion control during construction shall be provided as shown on the Erosion Control Plan. All erosion control measures shall be maintained in good repair by the Developer, until such time as the entire disturbed areas is stabilized with hard surface or landscaping. 21.The Developer shall be responsible for insuring that no mud or debris shall be tracked onto the existing public street system. Mud and debris must be removed within 24 hours by an appropriate mechanical method (i.e. machine broom sweep, light duty front-end loader, etc.) or as approved by the the City of Fort Collins street inspector. 22.No work may commence within any improved or unimproved public Right-of-Way until a Right-of-Way Permit or Development Construction Permit is obtained, if applicable. 23.The Developer shall be responsible for obtaining all necessary permits for all applicable agencies prior to commencement of construction. The Developer shall notify the the City of Fort Collins Inspector (Fort Collins - 221-6605) and the City of Fort Collins Erosion Control Inspector (Fort Collins - 221-6700) at least 2 working days prior to the start of any earth disturbing activity, or construction on any and all public improvements. If the City of Fort Collins Engineer is not available after proper notice of construction activity has been provided, the Developer may commence work in the Engineer's absence. However, the City of Fort Collins reserves the right not to accept the improvement if subsequent testing reveals an improper installation. 24.The Developer shall be responsible for obtaining soils tests within the Public Right-of-Way after right of way grading and all utility trench work is complete and prior to the placement of curb, gutter, sidewalk and pavement. If the final soils/pavement design report does not correspond with the results of the original geotechnical report, the Developer shall be responsible for a re-design of the subject pavement section or, the Developer may use the City of Fort Collins' default pavement thickness section(s). Regardless of the option used, all final soils/pavement design reports shall be prepared by a licensed Professional Engineer. The final report shall be submitted to the Inspector a minimum of 10 working days prior to placement of base and asphalt. Placement of curb, gutter, sidewalk, base and asphalt shall not occur until the City of Fort Collins Engineer approves the final report. 25.The contractor shall hire a licensed engineer or land surveyor to survey the constructed elevations of the street subgrade and the gutter flowline at all intersections, inlets, and other locations requested by the the City of Fort Collins inspector. The engineer or surveyor must certify in a letter to the City of Fort Collins that these elevations conform to the approved plans and specifications. Any deviations shall be noted in the letter and then resolved with the City of Fort Collins before installation of base course or asphalt will be allowed on the streets. 26.All utility installations within or across the roadbed of new residential roads must be completed prior to the final stages of road construction. For the purposes of these standards, any work except c/g above the subgrade is considered final stage work. All service lines must be stubbed to the property lines and marked so as to reduce the excavation necessary for building connections. 27.Portions of Larimer County are within overlay districts. The Larimer County Flood Plain Resolution should be referred to for additional criteria for roads within these districts. 28.All road construction in areas designated as Wild Fire Hazard Areas shall be done in accordance with the construction criteria as established in the Wild Fire Hazard Area Mitigation Regulations in force at the time of final plat approval. 29.Prior to the commencement of any construction, the contractor shall contact the Local Entity Forester to schedule a site inspection for any tree removal requiring a permit. 30.The Developer shall be responsible for all aspects of safety including, but not limited to, excavation, trenching, shoring, traffic control, and security. Refer to OSHA Publication 2226, Excavating and Trenching. 31.The Developer shall submit a Construction Traffic Control Plan, in accordance with MUTCD, to the appropriate Right-of-Way authority. (The the City of Fort Collins, Larimer County, Colorado), for approval, prior to any construction activities within, or affecting, the Right-of-Way. The Developer shall be responsible for providing any and all traffic control devices as may be required by the construction activities. 32.Prior to the commencement of any construction that will affect traffic signs of any type, the contractor shall contact the City of Fort Collins Traffic Operations Department, who will temporarily remove or relocate the sign at no cost to the contractor, however, if the contractor moves the traffic sign then the contractor will be charged for the labor, materials and equipment to reinstall the sign as needed. 33.The Developer is responsible for all costs for the initial installation of traffic signing and striping for the Development related to the Development's local street operations. In addition, the Developer is responsible for all costs for traffic signing and striping related to directing traffic access to and from the Development. 34.There shall be no site construction activities on Saturdays, unless specifically approved by the City of Fort Collins Engineer, and no site construction activities on Sundays or holidays, unless there is prior written approval by Larimer County. 35.The Developer is responsible for providing all labor and materials necessary for the completion of the intended improvements, shown on these drawings, or designated to be provided, installed, or constructed, unless specifically noted otherwise. 36.Dimensions for layout and construction are not to be scaled from any drawing. If pertinent dimensions are not shown, contact the Designer for clarification, and annotate the dimension on the as-built record drawings. 37.The Developer shall have, onsite at all times, one (1) signed copy of the approved plans, one (1) copy of the appropriate standards and specifications, and a copy of any permits and extension agreements needed for the job. 38.If, during the construction process, conditions are encountered which could indicate a situation that is not identified in the plans or specifications, the Developer shall contact the Designer and the City of Fort Collins Engineer immediately. 39.The Developer shall be responsible for recording as-built information on a set of record drawings kept on the construction site, and available to the Larimer County's Inspector at all times. Upon completion of the work, the contractor(s) shall submit record drawings to the City of Fort Collins Engineer. 40.The Designer shall provide, in this location on the plan, the location and description of the nearest survey benchmarks (2) for the project as well as the basis of bearings. The information shall be as follows: PROJECT DATUM: NAVD88 CITY OF FORT COLLINS BENCHMARK 2-02 EAST SIDE OF TIMBERLAND ROAD, 1/2 MILE NORTH OF TRILBY ROAD, ON THE MIDDLE CONCRETE PAD TO AN ELECTRIC BOX. ELEVATION: 4964.37 CITY OF FORT COLLINS BENCHMARK 12-13 SOUTHEAST CORNER OF TIMBERLINE RD. AND TRILBY RD., ON A CONCRETE TRAFFIC SIGNAL BASE. ELEVATION: 4926.67 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) = NAVD88 - 3.19' BASIS OF BEARINGS THE EAST LINE OF THE SOUTHEAST QUARTER OF SECTION 7, TOWNSHIP 6 NORTH, RANGE 68 WEST OF THE 6TH P.M. AS BEARING NORTH 00°06'07" EAST 41.All stationing is based on centerline of roadways unless otherwise noted. 42.Damaged curb, gutter and sidewalk existing prior to construction, as well as existing fences, trees, streets, sidewalks, curbs and gutters, landscaping, structures, and improvements destroyed, damaged or removed due to construction of this project, shall be replaced or restored in like kind at the Developer's expense, unless otherwise indicated on these plans, prior to the acceptance of completed improvements and/or prior to the issuance of the first Certificate of Occupancy. 43.When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the City of Fort Collins Construction Inspector before any cuts are made. Patching shall be done in accordance with the City of Fort Collins Street Repair Standards. The finished patch shall blend in smoothly into the existing surface. All large patches shall be paved with an asphalt lay-down machine. In streets where more than one cut is made, an overlay of the entire street width, including the patched area, may be required. The determination of need for a complete overlay shall be made by the Larimer County Engineer and/or the City of Fort Collins Inspector at the time the cuts are made. 44.Upon completion of construction, the site shall be cleaned and restored to a condition equal to, or better than, that which existed before construction, or to the grades and condition as required by these plans. 45.Standard Handicap ramps are to be constructed at all curb returns and at all "T" intersections. 46.After acceptance by the City of Fort Collins, public improvements depicted in these plans shall be guaranteed to be free from material and workmanship defects for a minimum period of two years from the date of acceptance. 47.The City of Fort Collins shall not be responsible for the maintenance of roadway and appurtenant improvements, including storm drainage structures and pipes, for the following private streets: N.A. 48.Approved Variances are listed as follows: N/A CONSTRUCTION NOTES A. Grading and Erosion Control Notes 1.The erosion control inspector must be notified at least twenty-four (24) hours prior to any construction on this site. 2.There shall be no earth-disturbing activity outside the limits designated on the accepted plans. 3.All required perimeter silt and construction fencing shall be installed prior to any land disturbing activity (stockpiling, stripping, grading, etc). All other required erosion control measures shall be installed at the appropriate time in the construction sequence as indicated in the approved project schedule, construction plans, and erosion control report. 4.At all times during construction, the Developer shall be responsible for preventing and controlling on-site erosion including keeping the property sufficiently watered so as to minimize wind blown sediment. The Developer shall also be responsible for installing and maintaining all erosion control facilities shown herein. 5.Pre-disturbance vegetation shall be protected and retained wherever possible. Removal or disturbance of existing vegetation shall be limited to the area(s) required for immediate construction operations, and for the shortest practical period of time. 6.All soils exposed during land disturbing activity (stripping, grading, utility installations, stockpiling, filling, etc.) shall be kept in a roughened condition by ripping or disking along land contours until mulch, vegetation, or other permanent erosion control BMPs are installed. No soils in areas outside project street rights-of-way shall remain exposed by land disturbing activity for more than thirty (30) days before required temporary or permanent erosion control (e.g. seed/mulch, landscaping, etc.) is installed, unless otherwise approved by the City/County. 7.In order to minimize erosion potential, all temporary (structural) erosion control measures shall: a.Be inspected at a minimum of once every two (2) weeks and after each significant storm event and repaired or reconstructed as necessary in order to ensure the continued performance of their intended function. b.Remain in place until such time as all the surrounding disturbed areas are sufficiently stabilized as determined by the erosion control inspector. c.Be removed after the site has been sufficiently stabilized as determined by the erosion control inspector. 8.When temporary erosion control measures are removed, the Developer shall be responsible for the clean up and removal of all sediment and debris from all drainage infrastructure and other public facilities. 9.The contractor shall immediately clean up any construction materials inadvertently deposited on existing streets, sidewalks, or other public rights of way, and make sure streets and walkways are cleaned at the end of each working day. 10.All retained sediments, particularly those on paved roadway surfaces, shall be removed and disposed of in a manner and location so as not to cause their release into any waters of the United States. 11.No soil stockpile shall exceed ten (10) feet in height. All soil stockpiles shall be protected from sediment transport by surface roughening, watering, and perimeter silt fencing. Any soil stockpile remaining after thirty (30) days shall be seeded and mulched. 12.The stormwater volume capacity of detention ponds will be restored and storm sewer lines will be cleaned upon completion of the project and before turning the maintenance over to the City/County or Homeowners Association (HOA). 13.City Ordinance and Colorado Discharge Permit System (CDPS) requirements make it unlawful to discharge or allow the discharge of any pollutant or contaminated water from construction sites. Pollutants include, but are not limited to discarded building materials, concrete truck washout, chemicals, oil and gas products, litter, and sanitary waste. The developer shall at all times take whatever measures are necessary to assure the proper containment and disposal of pollutants on the site in accordance with any and all applicable local, state, and federal regulations. 14.A designated area shall be provided on site for concrete truck chute washout. The area shall be constructed so as to contain washout material and located at least fifty (50) feet away from any waterway during construction. Upon completion of construction activities the concrete washout material will be removed and properly disposed of prior to the area being restored. 15.Conditions in the field may warrant erosion control measures in addition to what is shown on these plans. The Developer shall implement whatever measures are determined necessary, as directed by the City. B. Street Improvement Notes 1.All street construction is subject to the General Notes on the cover sheet of these plans as well as the Street Improvements Notes listed here. 2.A paving section design, signed and stamped by a Colorado licensed Engineer, must be submitted to the City of Fort Collins Engineer for approval, prior to any street construction activity, (full depth asphalt sections are not permitted at a depth greater than 8 inches of asphalt). The job mix shall be submitted for approval prior to placement of any asphalt. 3.Where proposed paving adjoins existing asphalt, the existing asphalt shall be saw cut, a minimum distance of 12 inches from the existing edge, to create a clean construction joint. The Developer shall be required to remove existing pavement to a distance where a clean construction joint can be made. Wheel cuts shall not be allowed unless approved by the City of Fort Collins Engineer in Fort Collins. 4.Street subgrades shall be scarified the top 12 inches and re-compacted prior to subbase installation. No base material shall be laid until the subgrade has been inspected and approved by the City of Fort Collins Engineer. 5.Ft. Collins only. Valve boxes and manholes are to be brought up to grade at the time of pavement placement or overlay. Valve box adjusting rings are not allowed. 6.When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the Inspector before any cuts are made. Cutting and patching shall be done in conformance with Chapter 25, Reconstruction and Repair. The finished patch shall blend smoothly into the existing surface. The determination of need for a complete overlay shall be made by the City of Fort Collins Engineer. All overlay work shall be coordinated with adjacent landowners such that future projects do not cut the new asphalt overlay work. 7.All traffic control devices shall be in conformance with these plans or as otherwise specified in M.U.T.C.D. (including Colorado supplement) and as per the Right-of-Way Work Permit traffic control plan. 8.The Developer is required to perform a gutter water flow test in the presence of the City of Fort Collins Inspector and prior to installation of asphalt. Gutters that hold more than 1/4 inch deep or 5 feet longitudinally, of water, shall be completely removed and reconstructed to drain properly. 9.Prior to placement of H.B.P. or concrete within the street and after moisture/density tests have been taken on the subgrade material (when a full depth section is proposed) or on the subgrade and base material (when a composite section is proposed), a mechanical "proof roll" will be required. The entire subgrade and/or base material shall be rolled with a heavily loaded vehicle having a total GVW of not less than 50,000 lbs. and a single axle weight of at least 18,000 lbs. with pneumatic tires inflated to not less that 90 p.s.i.g. "Proof roll" vehicles shall not travel at speeds greater than 3 m.p.h. Any portion of the subgrade or base material which exhibits excessive pumping or deformation, as determined by the City of Fort Collins Engineer, shall be reworked, replaced or otherwise modified to form a smooth, non-yielding surface. The City of Fort Collins Engineer shall be notified at least 24 hours prior to the "proof roll." All "proof rolls" shall be preformed in the presence of an Inspector. C. Traffic Signing and Pavement Marking Construction Notes 1.All signage and marking is subject to the General Notes on the cover sheet of these plans, as well as the Traffic Signing and Marking Construction Notes listed here. 2.All symbols, including arrows, ONLYS, crosswalks, stop bars, etc. shall be pre-formed thermo-plastic. 3.All signage shall be per the City of Fort Collins Standards and these plans or as otherwise specified in MUTCD. 4.All lane lines for asphalt pavement shall receive two coats of latex paint with glass beads. 5.All lane lines for concrete pavement should be epoxy paint. 6.Prior to permanent installation of traffic striping, symbols, and signs their placement shall be approved by the City of Fort Collins Traffic Engineer. The developer shall place temporary tabs, tape or flags depicting alignment and location. Contact City of Fort COllins Traffic Operations at 970-221-6630 for field review. 7.Pre-formed thermo-plastic applications shall be as specified in these Plans and/or these Standards. 8.Epoxy applications shall be applied as specified in CDOT Standard Specifications for Road and Bridge Construction. 9.All surfaces shall be thoroughly cleaned prior to installation of striping or markings. 10.All sign posts shall utilize break-away assemblies and fasteners per the Standards. 11.A field inspection of location and installation of all signs shall be performed by the City of Fort Collins Traffic Engineer. All discrepancies identified during the field inspection must be corrected before the 2-year warranty period will begin. 12.The Developer installing signs shall be responsible for locating and protecting all underground utilities. 13.Special care shall be taken in sign location to ensure an unobstructed view of each sign. 14.Signage and striping has been determined by information available at the time of review. Prior to initiation of the warranty period,the City of Fort Collins Traffic Engineer reserves the right to require additional signage and/or striping if the City of Fort Collins Traffic Engineer determines that an unforeseen condition warrants such signage according to the MUTCD or the CDOT M and S Standards. All signage and striping shall fall under the requirements of the 2-year warranty period for new construction (except fair wear on traffic markings). 15.Sleeves for sign posts shall be required for use in islands/medians. Refer to Chapter 14, Traffic Control Devices, for additional detail. D. Storm Drainage Notes 1.The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 2.All recommendations of the Preliminary Drainage Report for Timber Lark, dated July 9, 2021 by Northern Engineering Services, Inc., shall be followed and implemented. 3.Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must by submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall by submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. E. Utility Notes 1.All water and sanitary sewer construction shall be performed according to the Fort Collins-Loveland Water District and the South Fort Collins Sanitation District standards and specifications. 2.Construction of water and sewer facilities require a precon meeting with district operations staff prior to construction. 3.Contractor shall notify district inspectors prior to starting work. 4.Contractor shall contact the sanitation district for sewer inspection 48 hours prior to connecting to existing sewer stubs. 5.All commercial domestic services require a reduced pressure backflow prevention device. 6.All water lines shall be a minimum of (5) five feet and a maximum of (6) feet below final grade. 7.All district shall only be operated by district operations staff. 8.Pipe Pressure and vacuum testing shall be witnessed by district inspectors. Waterline bacteria tests shall also be taken by district inspectors. 9.Once the system is operational and all tests have passed, contractor shall request substantial completion with a letter to the district that includes the dollar value of the water and sewer improvements listed separately. 10.As-builts shall be submitted in pdf and dwg to the district for final approval. 11.If groundwater is encountered within the depth of sewer construction, manholes must be water-proofed. 12.The size, type and location of all known underground utilities are approximate when shown on these drawings. It shall be the responsibility of the contractor to verify the existence of all underground utilities in the area of work. Before commencing new construction , the contractor shall be responsible for locating all underground utilities and shall be responsible for all unknown underground utilities. 13.All water fittings and valves are only graphically represented and are not to scale. 14.Manhole rim elevations are to be adjusted to 1 4" below finished grade. If necessary, cone sections shall be rotated to prevent lids being located within bicycle or vehicle wheel paths CS2 CONSTRUCTION NOTESGENERAL &2 CORONAAVEGOLDEN WILLOWDRIVEFO HY DHY DC EC HY DLID S D CABLE ELEC ELEC ELEC BRKRE VAULT F.O. FO ELEC BRKRE D S D SELEC BRKREEE HY DFE SXXXXXXXXXXXXXXXXXXXX X XXXXXXXXXXXFOFOFOFOXXXWWWXXXXXXXXXXXXXXXXXXXXXXX X X X X X X X X X XXXXX OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHUSSSSSSSSSSSSSSSSSSSTSTSTSTSTSTSTST D S STRED WILLOWDRIVEEXISTING 20' NON-EXCLUSIVE EASEMENT (BOOK 1891 PAGE 939) TO BE VACATED EXISTING TREES TO BE REMOVED (TYPICAL) EXISTING 40' EASEMENT & ROW (REC. NO. 2001017733) TO BE VACATED EXISTING STORM DRAIN MANHOLE TO REMAIN (TYPICAL) EXISTING SANITARY MANHOLE TO REMAIN (TYPICAL) EXISTING 30" RCP STORM DRAIN TO REMAIN (TYPICAL) EXISTING 12" SANITARY TO REMAIN (TYPICAL) EXISTING SANITARY MANHOLE EXISTING STORM DRAIN MANHOLE TO REMAIN (TYPICAL) EXISTING FIRE HYDRANT EXISTING 8" WATER GAVE VALVE EXISTING ELECTRICAL BOXES (TYPICAL) EXISTING 12" WATERLINE EXISTING CABLE BOX EXISTING FIBRE OPTIC CABLE LINES TO REMAIN 50' R.O.W.DEDICATED PER BOOK 2117,PAGE 226EXISTING 5' TELECOMMUNICATIONS FACILITIES EASEMENT (REC. NO. 950068218) EXISTING OVERHEAD ELECTRICAL POWER LINES TO REMAIN EXISTING OVERHEAD ELECTRICAL POWER LINES TO REMAIN EXISTING IRRIGATION TO BE REMOVED EXISTING CONCRETE IRRIGATION STRUCTURE TO BE REMOVED EXISTING FENCE TO BE REMOVED EXISTING GATE TO BE REMOVED EXISTING FENCE TO BE REMOVED EXISTING 20' EASEMENT (REC. NO. 20120069975) TO BE VACATED ASSUMED LOCATION OF EXISTING 8" WATER STUB CONTRACTOR NEEDS TO VERIFY PRIOR TO CONSTRUCTION END CAP TO BE REMOVED FOR CONNECTION FALCON RIDGE DRIVE FOSSIL CREEKCIRCLEFOSSIL CREEK PARKWAY FOSSIL CREEKCIRCLEFALCON RIDGE DRIVE FOSSIL CREEK PARKWAY TIMBERLINE ROADU.P.R.R. RIGHT OF WAYEXISTING FENCE TO BE REMOVED EXISTING TREES TO BE REMOVED (TYPICAL) LOT 19 LOT 18 LOT 17 LOT 16 LOT 15 LOT 14 LOT 13 LOT 12 LINDEN PARK P.D.P., 1ST REPLAT LOT 11 LOT 10 LOT 9 LOT 8 LOT 7 LOT 6 LOT 5 LOT 4 LOT 3 LOT 2 LINDEN PARK P.D.P., 1ST REPLAT LOT 1 EXISTING IRRIGATION DITCH TO BE REMOVED EXISTING IRRIGATION STRUCTURE TO BE REMOVEDWEEPINGWILLOWDRIVEEXISTING TREE TO BE PROTECTED EXISTING IRRIGATION DITCH TO BE REMOVED LOT 168 LOT 159 LOT 157 LOT 156 LOT 158 LINDEN PARK P.D.P., 1ST REPLAT LOT 74LOT 75LOT 76LOT 77LOT 78LOT 79LOT 80 LOT 70 LOT 68 LOT 67 LOT 66 LOT 65 LOT 64 OWNER: JACQUELYN & LANE HANSON 1630 E TRILBY RD OWNER: MATTHEW ALLDREDGE 1702 E TRILBY RD OWNER: RIC & CHERYL LEWIS 1790 E TRILBY RD OWNER: RIC & CHERYL LEWIS 1854 E TRILBY RD OWNER: SUSAN LEVINE REVOCABLE TRUST 1900 E TRILBY RD OWNER: BARBARA KEEN LIVING TRUST 6417 S TIMBERLINE RDGOLDEN WILLOWDRIVEFO HY DHY DXXXXXXXXXXXXXXXXXXX EXISTING 8" WATER GATE VALVE EXISTING FIRE HYDRANT EXISTING FENCE ALONG PROPERTY BOUNDARY EXISTING CONCRETE IRRIGATION STRUCTURE TO REMAIN EXISTING TREES TO REMAIN EXISTING IRRIGATION TO BE REMOVED EXISTING 8" WATER GATE VALVE FALCON RIDGE DRIVE LOT 19 LOT 18 LOT 17 LOT 16 LOT 15 LOT 14 LOT 13 LOT 12 LINDEN PARK P.D.P., 1ST REPLAT LOT 11 EXISTING RETAINING WALL TO BE REMOVED EXISTING IRRIGATION DITCH TO BE REMOVED ASSUMED LOCATION OF EXISTING 8" WATER STUB CONTRACTOR NEEDS TO VERIFY PRIOR TO CONSTRUCTION END CAP TO BE REMOVED FOR CONNECTION ASSUMED LOCATION OF EXISTING 8" WATER STUB CONTRACTOR NEEDS TO VERIFY PRIOR TO CONSTRUCTION END CAP TO BE REMOVED FOR CONNECTION EXISTING FIBRE OPTIC CABLE BOX EXISTING FIRE HYDRANT WEEPINGWILLOW DRIVELOT 168 CORONAAVEHY DFES X X X X X XXXXXX X X X EXISTING 16" IRRIGATION LINES TO BE REMOVED EXISTING 24" IRRIGATION ADS TO REMAIN EXISTING 20' EASEMENT (REC. NO. 20120069975) TO BE VACATED FIBRE OPTIC CABLE LINES ASSUMED LOCATION OF EXISTING 8" WATER STUB CONTRACTOR NEEDS TO VERIFY PRIOR TO CONSTRUCTION END CAP TO BE REMOVED FOR CONNECTION EXISTING FENCE TO BE REMOVED FALCON RIDGE DRIVE LOT 4 LOT 3 LOT 2 LINDEN PARK P.D.P., 1ST REPLAT LOT 1 EXISTING IRRIGATION DITCH TO BE REMOVED EXISTING FIRE HYDRANT (TYPICAL) EXISTING 8" WATER VALVE (TYPICAL) EXISTING IRRIGATION CONCRETE STRUCTURE TO BE REMOVED AND REPLACED LOT 74 LOT 70 LOT 68 LOT 67 LOT 66 LOT 65 LOT 64 SheetTIMBER LARK RESIDENTIALThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 29 EXISTING ELECTRIC E LEGEND: G T EXISTING STORM SEWER ST EXISTING TELEPHONE EXISTING GAS EXISTING IRRIGATION BOX EXISTING GAS METER EXISTING TELEPHONE PEDESTAL EXISTING TREES (TO REMAIN) NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL, REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL. 3.CONTRACTOR IS ENCOURAGED TO PERFORM DEMOLITION IN A MANNER THAT MAXIMIZES SALVAGE, RE-USE, AND RECYCLING OF MATERIALS. THIS INCLUDES APPROPRIATE SORTING AND STORING. IN PARTICULAR, DEMOLISHED CONCRETE, ASPHALT, AND BASE COURSE SHOULD BE RECYCLED IF POSSIBLE. THE CITY OF FORT COLLINS STREET DEPARTMENT OPERATES A CRUSHING OPERATION THAT WILL ACCEPT CONCRETE MATERIAL AT NO COST FOR CRUSHING AND RE-USE AS RECYCLED AGGREGATE. THIS OPERATION IS LOCATED AT 1380 HOFFMAN MILL ROAD AND CAN BE REACHED AT (970) 482-1249. 4.ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5.CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING SITE SURVEY. 6.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. EXISTING SANITARY SEWER SS EXISTING WATER W EXISTING FENCE X EXISTING WATER METER EXISTING FIRE HYDRANT EXISTING ELECTRIC VAULT PROJECT BOUNDARY EXISTING RIGHT-OF-WAY EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR VAULT ELEC CONTROL IRR EXISTING TREES (TO BE REMOVED) APPROXIMATE LIMITS OF CONCRETE/ ASPHALT REMOVAL OR MILL & OVERLAY 1.ALL EXISTING TREES WITHIN THE LIMITS OF THE DEVELOPMENT AND WITHIN ANY NATURAL AREA BUFFER ZONES SHALL REMAIN AND BE PROTECTED UNLESS NOTED ON THESE PLANS FOR REMOVAL. 2.WITHIN THE DRIP LINE OF ANY PROTECTED EXISTING TREE, THERE SHALL BE NO CUT OR FILL OVER A FOUR-INCH DEPTH UNLESS A QUALIFIED ARBORIST OR FORESTER HAS EVALUATED AND APPROVED THE DISTURBANCE. 3.ALL PROTECTED EXISTING TREES SHALL BE PRUNED TO THE CITY OF FORT COLLINS FORESTRY STANDARDS. TREE PRUNING AND REMOVAL SHALL BE PERFORMED BY A BUSINESS THAT HOLDS A CURRENT CITY OF FORT COLLINS ARBORIST LICENSE WHERE REQUIRED BY CODE. 4.PRIOR TO AND DURING CONSTRUCTION, BARRIERS SHALL BE ERECTED AROUND ALL PROTECTED EXISTING TREES WITH SUCH BARRIERS TO BE OF ORANGE FENCING A MINIMUM OF FOUR (4) FEET IN HEIGHT, SECURED WITH METAL T-POSTS, NO CLOSER THAN SIX (6) FEET FROM THE TRUNK OR ONE-HALF (½) OF THE DRIP LINE, WHICHEVER IS GREATER. THERE SHALL BE NO STORAGE OR MOVEMENT OF EQUIPMENT, MATERIAL, DEBRIS OR FILL WITHIN THE FENCED TREE PROTECTION ZONE. 5.DURING THE CONSTRUCTION STAGE OF DEVELOPMENT, THE APPLICANT SHALL PREVENT THE CLEANING OF EQUIPMENT OR MATERIAL OR THE STORAGE AND DISPOSAL OF WASTE MATERIAL SUCH AS PAINTS, OILS, SOLVENTS, ASPHALT, CONCRETE, MOTOR OIL OR ANY OTHER MATERIAL HARMFUL TO THE LIFE OF A TREE WITHIN THE DRIP LINE OF ANY PROTECTED TREE OR GROUP OF TREES. 6.NO DAMAGING ATTACHMENT, WIRES, SIGNS OR PERMITS MAY BE FASTENED TO ANY PROTECTED TREE. 7.LARGE PROPERTY AREAS CONTAINING PROTECTED TREES AND SEPARATED FROM CONSTRUCTION OR LAND CLEARING AREAS, ROAD RIGHTS-OF-WAY AND UTILITY EASEMENTS MAY BE "RIBBONED OFF," RATHER THAN ERECTING PROTECTIVE FENCING AROUND EACH TREE AS REQUIRED IN SUBSECTION (G)(3) ABOVE. THIS MAY BE ACCOMPLISHED BY PLACING METAL T-POST STAKES A MAXIMUM OF FIFTY (50) FEET APART AND TYING RIBBON OR ROPE FROM STAKE-TO-STAKE ALONG THE OUTSIDE PERIMETERS OF SUCH AREAS BEING CLEARED 8.THE INSTALLATION OF UTILITIES, IRRIGATION LINES OR ANY UNDERGROUND FIXTURE REQUIRING EXCAVATION DEEPER THAN SIX (6) INCHES SHALL BE ACCOMPLISHED BY BORING UNDER THE ROOT SYSTEM OF PROTECTED EXISTING TREES AT A MINIMUM DEPTH OF TWENTY-FOUR (24) INCHES. THE AUGER DISTANCE IS ESTABLISHED FROM THE FACE OF THE TREE (OUTER BARK) AND IS SCALED FROM TREE DIAMETER AT BREAST HEIGHT AS DESCRIBED IN THE FOLLOWING CHART: 9.NO TREES SHALL BE REMOVED DURING THE SONGBIRD NESTING SEASON (FEBRUARY 1-JULY 31) WITHOUT FIRST HAVING A PROFESSIONAL ECOLOGIST OR WILDLIFE BIOLOGIST COMPLETE A NESTING SURVEY TO IDENTIFY ANY ACTIVE NESTS EXISTING ON THE PROJECT SITE. IF ACTIVE NESTS ARE FOUND, THE CITY ENVIRONMENTAL PLANNER WILL DETERMINE WHETHER ADDITIONAL RESTRICTIONS ON TREE REMOVAL AND CONSTRUCTION APPLY. 10.REFER TO LANDSCAPE AND IRRIGATION PLANS FOR ADDITIONAL TREE PROTECTION MEASURES. TREE PROTECTION NOTES: NORTH ( IN FEET ) 0 1 INCH = 100 FEET 100 100 200 300 EX1 & DEMOLITION PLANEXISTING CONDITIONS3 SEE BELOW FOR OVERALL VIEWSEE BELOW FOR OVERALL VIEW SEE ABOVE FOR DETAILED VIEW SEE ABOVE FOR DETAILED VIEW CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R GOLDEN WILLOWDRIVECORONAAVEFO HY DHY DC C HY DLID S D CABLE VAULT F.O. FO D S D S HY DFE SFOFOFOFOWWWOHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHUSSSSSSSSSSSSSSSSSSSTSTSTSTSTSTSTST D S STS S S S S S S S S S S WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW WWWWWWWWWWSSSSSSSSSSSSS S S S S S S S S S S S S S S S S S S S S S S S SWWSWSWSWSWSWSWSSWSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWSSSSSSWWWWWWSSSSSSW WWWWWWSSSSSSWWWWWWWWSSSSSSSSWWWWSSSSSSWWWWSSSSSSWWSSWWWWSSSSSSWWSSWWWWWWSSWWSSWWWWSSUD IRR IRR IRRIRRIRR IRR IRR IRR IRR IRRIRRIRRIRRIRRIRRIRRWUDUDUDUDUDUDWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW WWWWWWWWWWWWWSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS S S S S S SS W W 8" SANITARY (TYPICAL) 8" WATER (TYPICAL) WATER SERVICE (TYPICAL) SANITARY SERVICE (TYPICAL) FALCON RIDGE DRIVE FOSSIL CREEKCIRCLEFOSSIL CREEK PARKWAY FALCON RIDGE DRIVE FOSSIL CREEK PARKWAY TIMBERLINE ROADWEEPINGWILLOW DRIVERED WILLOWDRIVEFOSSIL CREEKCIRCLE8" SANITARY (TYPICAL) 8" WATER (TYPICAL) SANITARY MANHOLE (TYPICAL) UNDER DRAIN (TYPICAL) SANITARY MANHOLE (TYPICAL) STORM OUTLET (TYPICAL) PROPOSED FIRE HYDRANT 8" WATER STUB 8" WATER STUB 8" WATER STUB STORM DRAIN (TYPICAL) STORM DRAIN (TYPICAL) TYPE 'R' INLET (TYPICAL) EXISTING 30" STORM DRAIN EXISTING STORM DRAIN MANHOLE (TYPICAL) EXISTING OVERHEAD POWER LINES 8" WATER STUBU.P.R.R. RIGHT OF WAYUNDER DRAIN (TYPICAL) EXISTING SANITARY MANHOLE (TYPICAL) PROPOSED IRRIGATION LINE (TYPICAL) PROPOSED IRRIGATION LINE (TYPICAL) UNDERGROUND STORMTECH CHAMBERS DETENTION POND RAIN GARDEN 1 RAIN GARDEN 2 PROPOSED WATER CONNECTION PROPOSED WATER CONNECTION PROPOSED WATER CONNECTION CONNECTION TO EXISTING STORM DRAIN PROPOSED MANHOLE CONNECTION TO EXISTING SANITARY SEWER TRACT H UDA&EAE TRACT T DE TRACT Q OPEN SPACE TRACT E DUE TRACT N UDA&EAE TRACT D DETRACT C DETRACT B DE TRACT P DE TRACT R DE TRACT S DE TRACT J AE TRACT U DE TRACT L DE TRACT A TRACT F UDA&EAE TRACT G DAE TRACT M AE TRACT O DE BLOCK 2 BLOCK 10 BLOCK 11 BLOCK 12 BLOCK 5 BLOCK 1 BLOCK 9 BLOCK 8 BLOCK 7 BLOCK 13 BLOCK 14 BLOCK 15 BLOCK 17 BLOCK 18BLOCK 16 BLOCK 19 BLOCK 20 BLOCK 21 BLOCK 22 BLOCK 4BLOCK 3 PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT EXISTING FIRE HYDRANT LOT 19 LOT 18 LOT 17 LOT 16 LOT 15 LOT 14 LOT 13 LOT 12 LINDEN PARK P.D.P., 1ST REPLAT LOT 11 LOT 10 LOT 9 LOT 8 LOT 7 LOT 6 LOT 5 LOT 4 LOT 3 LOT 2 LINDEN PARK P.D.P., 1ST REPLAT LOT 1LOT 168 LOT 159 LOT 157 LOT 156 LOT 158 LINDEN PARK P.D.P., 1ST REPLAT LOT 74LOT 75LOT 76LOT 77LOT 78LOT 79LOT 80 LOT 70 LOT 68 LOT 67 LOT 66 LOT 65 LOT 64 PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT EXISTING FIRE HYDRANT PROPOSED FIRE HYDRANT OWNER: JACQUELYN & LANE HANSON 1630 E TRILBY RD OWNER: MATTHEW ALLDREDGE 1702 E TRILBY RD OWNER: RIC & CHERYL LEWIS 1790 E TRILBY RD OWNER: RIC & CHERYL LEWIS 1854 E TRILBY RD OWNER: SUSAN LEVINE REVOCABLE TRUST 1900 E TRILBY RD OWNER: BARBARA KEEN LIVING TRUST 6417 S TIMBERLINE RD EXISTING SANITARY SEWER STREET C GOLDEN WILLOW DRIVESTREET EWEEPING WILLOW DRIVESTREET GSTREET ICORONAAVENUEALLEY KALLEY LALLEY MALLEY NALLEY OALLEY PSTREET B STREET A STREET A RED WILLOW DRIVESheetTIMBER LARK RESIDENTIALThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 29 OU1 OVERALL UTILITY PLAN4 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORMLINE LEGEND: NOTES: W G T E EXISTING STORM SEWER ST PROPOSED ELECTRIC EXISTING TELEPHONE EXISTING GAS PROPOSED UNDERDRAIN EXISTING SANITARY SEWER SS PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT PROPOSED LOTLINE RIGHT OF WAY PROPERTY BOUNDARY SPROPOSED SEWER SERVICE WPROPOSED RESIDENTIAL WATER SERVICE PROPOSED SUBDRAIN UD SD EXISTING FIRE HYDRANT PROPOSED STORMLINE LIMITS OF DEVELOPMENT LOD EASEMENT LINE 1.ALL WATERLINE CONSTRUCTION SHALL CONFORM TO THE FORT COLLINS-LOVELAND WATER DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS CURRENT AT THE DATE OF CONSTRUCTION. 2.ALL SANITARY SEWER CONSTRUCTION SHALL CONFORM TO THE SOUTH FORT COLLINS SANITATION DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS CURRENT AT THE DATE OF CONSTRUCTION. 3.THE CONTRACTOR SHALL MAINTAIN A MINIMUM OF 10 FEET OF HORIZONTAL SEPARATION AND 18 INCHES OF VERTICAL SEPARATION BETWEEN ALL SEWER AND WATER LINES. 4.MINIMUM DEPTH OF COVER OVER WATER MAINS SHALL BE 5.0 FEET AND MAXIMUM COVER SHALL BE 6.0 FEET. 5.MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN BICYCLE OR VEHICLE WHEEL PATHS. 6.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 7.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 8.ALL WATER FITTINGS TO BE MECHANICALLY RESTRAINED PER FCLWD STANDARDS. 9.ALL WATER SERVICES SHALL BE 3/4" TYPE K COPPER. PROPOSED STREET LIGHT NORTH ( IN FEET ) 0 1 INCH = 100 FEET 100 100 200 300 KEYMAP WWWWW WWWWWWWWWWSSSSSSSSSSSSS S SWWSWIRR IRR IRR IRR WWWWWWWWWWWWWWWWWWWWWWWWWWWWWW WWWWWWWWWWWWWSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS S S S S S SW GOLDEN WILLOW DRIVEWEEPINGWILLOW DRIVEFO HY DHY D LID EE XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX X XXXXXXXXXXXX OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHUGOLDENWILLOW DRIVEU.P.R.R. RIGHT OF WAY53' ROW 53' ROW 52' ROW 53' ROW 53' ROW 53' ROW53' ROW 52' ROW STREET B STREET EWEEPING WILLOW DRIVESTREET B STREET A CONNECT TO EXISTING 8" WATER STUB CONNECT TO EXISTING 8" WATER STUB 8" WATER STUB PROPOSED FIRE HYDRANT 8" WATER STUB WATER SERVICE (TYPICAL) SANITARY SERVICE (TYPICAL) WATER SERVICE (TYPICAL) SANITARY SERVICE (TYPICAL) SSMH A7 SSMH A4-2 SSMH A4-1 SSMH A2-2 SSMH A3-1 SSMH A6 SSMH A5-1 SSMH A5 SSMH A4 SSMH A3 8" SANITARY STUB 8" SANITARY8" SANITARY 24" IRRIGATION 8" SANITARY8" WATER8" WATER 8" WATER8" SANITARY8" WATERLOT 12 TRACT A LOT 19LOT 18 LOT 17 LOT 16 LOT 14 LOT 1 LOT 15 LOT 2 LOT 13 LOT 5 LOT 4 LOT 4 LOT 4 LOT 3 LOT 2 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 LOT 11 LOT 12 LOT 6 LOT 4 LOT 3 LOT 2 LOT 5 LOT 1 LOT 1LOT 1 TRACT Q OPEN SPACE TRACT E DUE LOT 1LOT 4 LOT 2 LOT 2LOT 8LOT 5LOT 1 LOT 3 LOT 6LOT 2 LOT 7 LOT 6 LOT 5 LOT 2 LOT 3 LOT 1 LOT 1 LOT 6 LOT 2 LOT 3 LOT 5 LOT 7 LOT 5 LOT 4 LOT 6 LOT 3 LOT 8 LOT 9 LOT 10 LOT 11 STORM DRAIN A BLOCK 1 BLOCK 1 BLOCK 5 BLOCK 9 BLOCK 10 BLOCK 7 30' FL-FL 30' FL-FL 30' FL-FL 30' FL-FL 15' DRAINAGE EASEMENT PROPOSED CONCRETE CHANNEL TO TIE INTO EXISTING IRRIGATION STRUCTURE LOT 19 LOT 18 LOT 17 LOT 16 LOT 15 LOT 14 LOT 13 LOT 12 LINDEN PARK P.D.P., 1ST REPLAT LOT 11 LOT 10 LOT 9LOT 168 EXISTING FIRE HYDRANT EXISTING FIRE HYDRANT PROPOSED IRRIGATION INLET PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT 8" WATER STREET LIGHT N:98479.03 E:202824.72 STREET LIGHT N:98188.94 E:202864.08 STREET LIGHT N:98161.54 E:203056.87 STREET LIGHT N:98470.69 E:203128.50 STREET LIGHT N:98591.35 E:203335.69 STREET LIGHT N:98123.35 E:203411.41 STREET LIGHT N:98358.24 E:203394.32 OWNER: JACQUELYN & LANE HANSON 1630 E TRILBY RD OWNER: MATTHEW ALLDREDGE 1702 E TRILBY RD344' LF RETAINING WALL342' LF RETAINING WALL114' LF RETAINING WALL8' SIDEWALK8' SIDEWALK SheetTIMBER LARK RESIDENTIALThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 29 NORTH ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 UT1 UTILITY PLAN5 KEYMAP UT1 UT2 UT3 MATCHLINE SEE SHEET UT2EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORMLINE LEGEND: NOTES: W G T E EXISTING STORM SEWER ST PROPOSED ELECTRIC EXISTING TELEPHONE EXISTING GAS PROPOSED UNDERDRAIN EXISTING SANITARY SEWER SS PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT PROPOSED LOTLINE RIGHT OF WAY PROPERTY BOUNDARY SPROPOSED SEWER SERVICE WPROPOSED RESIDENTIAL WATER SERVICE PROPOSED SUBDRAIN UD SD EXISTING FIRE HYDRANT PROPOSED STORMLINE LIMITS OF DEVELOPMENT LOD EASEMENT LINE 1.ALL WATERLINE CONSTRUCTION SHALL CONFORM TO THE FORT COLLINS-LOVELAND WATER DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS CURRENT AT THE DATE OF CONSTRUCTION. 2.ALL SANITARY SEWER CONSTRUCTION SHALL CONFORM TO THE SOUTH FORT COLLINS SANITATION DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS CURRENT AT THE DATE OF CONSTRUCTION. 3.THE CONTRACTOR SHALL MAINTAIN A MINIMUM OF 10 FEET OF HORIZONTAL SEPARATION AND 18 INCHES OF VERTICAL SEPARATION BETWEEN ALL SEWER AND WATER LINES. 4.MINIMUM DEPTH OF COVER OVER WATER MAINS SHALL BE 5.0 FEET AND MAXIMUM COVER SHALL BE 6.0 FEET. 5.MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN BICYCLE OR VEHICLE WHEEL PATHS. 6.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 7.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 8.ALL WATER FITTINGS TO BE MECHANICALLY RESTRAINED PER FCLWD STANDARDS. 9.ALL WATER SERVICES SHALL BE 3/4" TYPE K COPPER. PROPOSED STREET LIGHT CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R WWWWWWWWWWWWWWWWWWWSSSSSSSSSSSSSSSSSSS S WSWSWSWSWSWSWSSWSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWSSSSSSW WWWWWWSSSSSSWWWWSSSSSSWWSSSSSSWWSSWWWWWWSSWWWWSSIRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRWUDUDUDUDHY DC EC S D ELEC BRKRE D S D SELEC BRKRE XXXXXXXXXXXXXXXXXXXXXXXXXXX X X X X X X X X X X X X X X X X X X X X X X X OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHUSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS SSSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST ST STRED WILLOWDRIVEUNDERGROUND STORMTECH CHAMBERS 57' ROW 51' ROW 57' ROW52' ROW 57' ROW 52' ROW 57' ROWSTREET GRED WILLOW DRIVESTREET IALLEY KALLEY LALLEY MALLEY OSTREET B STREET B STREET ISTREET A STREET A CONNECT TO EXISTING 8" WATER STUB 8" WATER STUB WATER SERVICE (TYPICAL) SANITARY SERVICE (TYPICAL) STREET C CONNECT TO EXISTING STORM DRAIN MANHOLE SSMH A2-2 SSMH A2-1 SSMH A1-1 SSMH B4 SSMH B3-1A SSMH B4-1 SSMH A2-1A SSMH B1-1 SSMH B3 SSMH A2 SSMH A1 SSMH B3-1 SSMH AB SSMH B2 SSMH B3-1B SSMH B1 24" IRRIGATION 24" IRRIGATION24" IRRIGATION24" IRRIGATION 8" SANITARY 8" SANITARY8" SANITARY8" SANITARY8" WATER8" WATER8" WATER EXISTING 8" SANITARY8" WATERLOT 4 LOT 5 LOT 9 LOT 7 LOT 8 LOT 10 LOT 10 LOT 9 LOT 8 LOT 7 LOT 3 LOT 5 LOT 4 LOT 1 LOT 2 TRACT R DE TRACT I UDA&EAE TRACT S DE LOT 2 LOT 4 LOT 3 LOT 1 LOT 6 LOT 5 LOT 7 LOT 6 LOT 4 LOT 5 LOT 7 LOT 2 LOT 3 LOT 1 TRACT O DE LOT 3 LOT 5 LOT 4 LOT 3 LOT 2 LOT 1 LOT 1 LOT 2 LOT 5 LOT 4 TRACT P DE TRACT C DETRACT B DE LOT 1 LOT 3 LOT 4 LOT 5 LOT 6 LOT 11LOT 8 LOT 9 LOT 10 LOT 6 LOT 4 LOT 3 LOT 2 LOT 5 LOT 10 LOT 11 LOT 12 LOT 7 LOT 8 LOT 9 LOT 6 TRACT F UDA&EAE TRACT G DAE LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 9 LOT 7 LOT 8 LOT 10 LOT 10 LOT 9 LOT 8 LOT 7 LOT 3 LOT 5 LOT 4 LOT 1 LOT 2 LOT 6 LOT 6 LOT 1 LOT 2 LOT 3 LOT 6 LOT 7 TRACT H UDA&EAE LOT 1 LOT 2LOT 10LOT 8LOT 7LOT 6LOT 5LOT 4LOT 3 LOT 9LOT 2 LOT 8LOT 5LOT 4LOT 3 LOT 6 LOT 7 LOT 10LOT 2 LOT 9 STORM DRAIN A STORM DRAIN A STORM DRAIN A BLOCK 15 BLOCK 16 BLOCK 19 BLOCK 20 BLOCK 3 BLOCK 2 BLOCK 10 BLOCK 12BLOCK 11 BLOCK 14BLOCK 13 BLOCK 8 30' FL-FL 36' FL-FL 36' FL-FL 30' FL-FL 30' FL-FL STORM DRAIN A STORM DRAIN B DETENTION POND LOT 10 LOT 9 LOT 8 LOT 7 LOT 6 LOT 5 LOT 4 LOT 159 LOT 157 LOT 156LOT 158 LOT 74LOT 75LOT 76LOT 77LOT 78LOT 79LOT 80 EXISTING FIRE EXISTING FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT STREET LIGHT N:98554.77 E:203680.19 STREET LIGHT STREET LIGHT N:98160.64 E:203599.28 STREET LIGHT N:98160.25 E:203835.64 STREET LIGHT N:98165.25 E:204259.32 STREET LIGHT N:98357.70 E:204307.86 STREET LIGHT N:98554.24 E:204328.26 STREET LIGHT N:98554.34 E:204071.66 STREET LIGHT N:98357.21 E:204006.36 STREET LIGHT N:98123.35 E:204071.21 STREET LIGHT N:98357.79 E:203659.32 STREET LIGHT N:98592.18 E:203852.00 STREET LIGHT PROPOSED IRRIGATION OUTLET OWNER: RIC & CHERYL LEWIS 1790 E TRILBY RD OWNER: RIC & CHERYL LEWIS 1854 E TRILBY RD OWNER: SUSAN LEVINE REVOCABLE TRUST 1900 E TRILBY RD SheetTIMBER LARK RESIDENTIALThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 29 NORTH ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 UT2 UTILITY PLAN6 KEYMAP UT1 UT2 UT3 MATCHLINE SEE SHEET UT3MATCHLINE SEE SHEET UT1EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORMLINE LEGEND: NOTES: W G T E EXISTING STORM SEWER ST PROPOSED ELECTRIC EXISTING TELEPHONE EXISTING GAS PROPOSED UNDERDRAIN EXISTING SANITARY SEWER SS PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT PROPOSED LOTLINE RIGHT OF WAY PROPERTY BOUNDARY SPROPOSED SEWER SERVICE WPROPOSED RESIDENTIAL WATER SERVICE PROPOSED SUBDRAIN UD SD EXISTING FIRE HYDRANT PROPOSED STORMLINE LIMITS OF DEVELOPMENT LOD EASEMENT LINE 1.ALL WATERLINE CONSTRUCTION SHALL CONFORM TO THE FORT COLLINS-LOVELAND WATER DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS CURRENT AT THE DATE OF CONSTRUCTION. 2.ALL SANITARY SEWER CONSTRUCTION SHALL CONFORM TO THE SOUTH FORT COLLINS SANITATION DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS CURRENT AT THE DATE OF CONSTRUCTION. 3.THE CONTRACTOR SHALL MAINTAIN A MINIMUM OF 10 FEET OF HORIZONTAL SEPARATION AND 18 INCHES OF VERTICAL SEPARATION BETWEEN ALL SEWER AND WATER LINES. 4.MINIMUM DEPTH OF COVER OVER WATER MAINS SHALL BE 5.0 FEET AND MAXIMUM COVER SHALL BE 6.0 FEET. 5.MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN BICYCLE OR VEHICLE WHEEL PATHS. 6.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 7.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 8.ALL WATER FITTINGS TO BE MECHANICALLY RESTRAINED PER FCLWD STANDARDS. 9.ALL WATER SERVICES SHALL BE 3/4" TYPE K COPPER. PROPOSED STREET LIGHT CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R S S S S S S S S S S S WWWWWWWWWWWWWWWWWSSSSS WWWWWWSSSSSSWWWWWWSSSSSSWWWWWWWWSSSSSSSSWWWWSSSSSSWWWWSSSSSSWWSSWWWWSSSSSSWWSSWWWWWWSSWWSSWWWWSSUD UD UD IRR IRR IRR IRR IRR IRRIRRIRRIRRIRRUDUDUDUDUDUDUDUDUDUDUDUDS WCORONAAVE CABLE ELEC ELEC ELEC BRKRE VAULT F.O. FO HY DFE SXXXXXXXX X X X XXXXXXXXXXXXXXXXXXXXXXXXXXXFOFOFOFOFOFOFOFOFOFOXXXXXXXXXWWWWWWWWXX X X X X OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU TIMBERLINE ROADRAIN GARDEN 1 RAIN GARDEN 2 DETENTION POND 57' ROW 53' ROW 52' ROW 20' EOC-TBC STREET C CORONAAVENUEALLEY MALLEY NALLEY OALLEY PSTREET A CONNECT TO EXISTING 8" WATER STUB CONNECT TO EXISTING 12" WATERLINE WATER SERVICE (TYPICAL) SANITARY SERVICE (TYPICAL) 8" SANITARY STUB 8" WATER STUB SSMH B5 SSMH B3-1A SSMH B3-2A SSMH B6 SSMH B3-1 SSMH B3-2 SSMH B3-1B SSMH B3-3 SSMH B3-2B 8" SANITARY 8" SANITARY 8" WATER8" SANITARY8" SANITARY8" WATER8" WATER 8" WATER PROPOSED STORM CULVERTS PROPOSED STORM CULVERTS 69.5' HALF ROW 57.5' HALF ROW TRACT I UDA&EAE TRACT S DE TRACT J AE TRACT U DE TRACT K UDA&EAE TRACT L DE LOT 6 LOT 4 LOT 5 LOT 7 LOT 2 LOT 3 LOT 1 LOT 2 LOT 4 LOT 3 LOT 1 LOT 6 LOT 5 LOT 7 LOT 6 LOT 4 LOT 5 LOT 7 LOT 2 LOT 3 LOT 1 TRACT M AE TRACT O DE LOT 3 LOT 4 LOT 3 LOT 1 LOT 2 LOT 5 LOT 4 LOT 5 LOT 1 LOT 2 LOT 1 LOT 2 LOT 5 LOT 4 LOT 3 TRACT D DE LOT 1 LOT 3 LOT 4 LOT 5 LOT 9LOT 7 LOT 8 LOT 11LOT 10 LOT 12LOT 2LOT 11LOT 9 LOT 10 LOT 6 TRACT T DE TRACT N UDA&EAE LOT 13LOT 12 LOT 14 STORM DRAIN C RAIN GARDEN 2 STORM DRAIN D STORM DRAIN E PROPOSED UNDERDRAIN PROPOSED IRRIGATION CHANNEL BLOCK 16 BLOCK 17 BLOCK 18 BLOCK 21BLOCK 20 BLOCK 22 BLOCK 4 PROPOSED UNDERDRAIN REPLACE CONCRETE IRRIGATION STRUCTURE WITH PROPOSED INLET 30' FL-FL 36' FL-FL LOT 4 LOT 3 LOT 2 LINDEN PARK P.D.P., 1ST REPLAT LOT 1LOT 74 LOT 70 LOT 68 LOT 67 LOT 66 LOT 65 LOT 64 EXISTING FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT STREET LIGHT N:98590.82 E:204584.01 STREET LIGHT N:98292.39 E:204645.00 PROPOSED IRRIGATION OUTLET OWNER: SUSAN LEVINE REVOCABLE TRUST 1900 E TRILBY RD OWNER: BARBARA KEEN LIVING TRUST 6417 S TIMBERLINE RD SheetTIMBER LARK RESIDENTIALThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 29 NORTH ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 UT3 UTILITY PLAN7 KEYMAP UT1 UT2 UT3 MATCHLINE SEE SHEET UT2EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORMLINE LEGEND: NOTES: W G T E EXISTING STORM SEWER ST PROPOSED ELECTRIC EXISTING TELEPHONE EXISTING GAS PROPOSED UNDERDRAIN EXISTING SANITARY SEWER SS PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT PROPOSED LOTLINE RIGHT OF WAY PROPERTY BOUNDARY SPROPOSED SEWER SERVICE WPROPOSED RESIDENTIAL WATER SERVICE PROPOSED SUBDRAIN UD SD EXISTING FIRE HYDRANT PROPOSED STORMLINE LIMITS OF DEVELOPMENT LOD EASEMENT LINE 1.ALL WATERLINE CONSTRUCTION SHALL CONFORM TO THE FORT COLLINS-LOVELAND WATER DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS CURRENT AT THE DATE OF CONSTRUCTION. 2.ALL SANITARY SEWER CONSTRUCTION SHALL CONFORM TO THE SOUTH FORT COLLINS SANITATION DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS CURRENT AT THE DATE OF CONSTRUCTION. 3.THE CONTRACTOR SHALL MAINTAIN A MINIMUM OF 10 FEET OF HORIZONTAL SEPARATION AND 18 INCHES OF VERTICAL SEPARATION BETWEEN ALL SEWER AND WATER LINES. 4.MINIMUM DEPTH OF COVER OVER WATER MAINS SHALL BE 5.0 FEET AND MAXIMUM COVER SHALL BE 6.0 FEET. 5.MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN BICYCLE OR VEHICLE WHEEL PATHS. 6.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 7.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 8.ALL WATER FITTINGS TO BE MECHANICALLY RESTRAINED PER FCLWD STANDARDS. 9.ALL WATER SERVICES SHALL BE 3/4" TYPE K COPPER. PROPOSED STREET LIGHT CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R CORONAAVEUD IRR IRR IRRIRRIRR IRR IRR IRR IRR IRRIRRIRRIRRIRRIRRIRRUDUDUDUDUDUDGOLDEN WILLOWDRIVED DD FE SSTSTSTSTSTSTSTST DST FALCON RIDGE DRIVE FOSSIL CREEKCIRCLEFOSSIL CREEK PARKWAY FALCON RIDGE DRIVE FOSSIL CREEK PARKWAY TIMBERLINE ROADUNDERGROUND STORM CHAMBERS RAIN GARDEN 2DETENTION POND STREET C GOLDEN WILLOW DRIVESTREET EWEEPING WILLOW DRIVESTREET GSTREET ICORONAAVENUEALLEY KALLEY LALLEY MALLEY NALLEY OALLEY PSTREET B STREET A STREET A RED WILLOW DRIVETRACT H UDA&EAETRACT E DUE TRACT N UDA&EAE TRACT M AE TRACT O DE LOT 5 TRACT F UDA&EAE TRACT G DAE TRACT I UDA&EAE TRACT J AE TRACT K UDA&EAE TRACT L DE TRACT D DE TRACT C DETRACT B DE BLOCK 9 BLOCK 10 BLOCK 11 BLOCK 12 BLOCK 13 BLOCK 15 BLOCK 16 BLOCK 17 BLOCK 18 BLOCK 7 BLOCK 8 BLOCK 22BLOCK 19 BLOCK 20 BLOCK 21 BLOCK 2 BLOCK 6 BLOCK 5 BLOCK 3 BLOCK 4 BLOCK 4WEEPINGWILLOW DRIVERED WILLOWDRIVEFOSSIL CREEKCIRCLEBLOCK 14 U.P.R.R. RIGHT OF WAYRETAINING WALL RETAINING WALL RAIN GARDEN 2 LOT 19 LOT 18 LOT 17 LOT 16 LOT 15 LOT 14 LOT 13 LOT 12 LINDEN PARK P.D.P., 1ST REPLAT LOT 11 LOT 10 LOT 9 LOT 8 LOT 7 LOT 6 LOT 5 LOT 4 LOT 3 LOT 2 LINDEN PARK P.D.P., 1ST REPLAT LOT 1LOT 168 LOT 159 LOT 157 LOT 156 LOT 158 LINDEN PARK P.D.P., 1ST REPLAT LOT 74LOT 75LOT 76LOT 77LOT 78LOT 79LOT 80 LOT 70 LOT 68 LOT 67 LOT 66 LOT 65 LOT 64 OWNER: JACQUELYN & LANE HANSON 1630 E TRILBY RD OWNER: MATTHEW ALLDREDGE 1702 E TRILBY RD OWNER: RIC & CHERYL LEWIS 1790 E TRILBY RD OWNER: RIC & CHERYL LEWIS 1854 E TRILBY RD OWNER: SUSAN LEVINE REVOCABLE TRUST 1900 E TRILBY RD OWNER: BARBARA KEEN LIVING TRUST 6417 S TIMBERLINE RD SheetTIMBER LARK RESIDENTIALThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 29 OGR1OVERALL GRADING PLAN8 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NORTH ( IN FEET ) 0 1 INCH = 100 FEET 100 100 200 300 KEYMAP LEGEND: ST 1.A DETAILED LOT GRADING PLAN SHALL BE PROVIDED AT THE TIME OF BUILDING PERMIT TO ENSURE COMPLIANCE WITH LOT CERTIFICATION REQUIREMENTS. THIS MAY REQUIRE RETAINING WALLS OR EXPOSED FOUNDATIONS TO MEET SLOPE REQUIREMENTS. 2.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 3.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS UNLESS OTHERWISE NOTED. 5.THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM. 6.CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 7.ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 36.25 (36.25) 2.0% NOTES: PROPOSED SLOPES EXISTING SPOT ELEVATION PROPOSED SPOT ELEVATION PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE EXISTING CONTOUR PROPOSED CONTOUR PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER LODLIMITS OF DEVELOPMENT PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) 1.THE NATURAL HABITAT BUFFER ZONES ARE INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONES. NATURAL HABITAT BUFFER ZONES IRR IRR IRR IRR 53' ROW 52' ROW 53' ROW 53' ROW53' ROW 53' ROW 52' ROW WEEPINGWILLOW DRIVEGOLDENWILLOW DRIVEXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX X XXXXXXXXXXXX OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHUU.P.R.R. RIGHT OF WAYLOT 1 LOT 1LOT 1 TRACT Q OPEN SPACE TRACT E DUE LOT 1LOT 4 LOT 2 LOT 2LOT 8LOT 5LOT 1 LOT 3 LOT 6LOT 2 LOT 7 LOT 6 LOT 5 LOT 2 LOT 3 LOT 1 LOT 1 LOT 6 LOT 2 LOT 3 LOT 5 LOT 7 LOT 5 LOT 4 LOT 6 LOT 3 LOT 8 LOT 9 LOT 10 LOT 11 LOT 4 LOT 3 LOT 2 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 LOT 11 LOT 12 LOT 6 LOT 4 LOT 3 LOT 2 LOT 5 LOT 4 LOT 4 BLOCK 9 BLOCK 10 BLOCK 7 BLOCK 6 BLOCK 5 STREET BGOLDEN WILLOW DRIVESTREET EWEEPING WILLOW DRIVESTREET B STREET A 6' CONCRETE PAN (TYPICAL)344' LF RETAINING WALL342' LF RETAINING WALL114' LF RETAINING WALL8' SIDEWALK8' SIDEWALK8' SIDEWALK 52' ROW6.9%2.3%3.4% 3. 0% 3.1% 3.2% 2 . 5%2.5%2.3%3.7%INLET A8 STMH A7 STMH A5 INLET A6-1A STMH A6 INLET A6-1B IR INLET A5 PROPOSED CONCRETE CHANNEL TO TIE INTO EXISTING IRRIGATION STRUCTURE LOT 19LOT 18LOT 17LOT 16 LOT 14 LOT 15 LOT 2 LOT 13 LOT 1 LOT 5LOT 12 PROPOSED CONCRETE CHANNEL (6" CURB) PROPOSED CURB CUT AND SIDEWALK CHASE 15' DRAINAGE EASEMENT LOT 19 LOT 18 LOT 17 LOT 16 LOT 15 LOT 14 LOT 13 LOT 12 LINDEN PARK P.D.P., 1ST REPLAT LOT 11 LOT 10 LOT 9LOT 168 OWNER: JACQUELYN & LANE HANSON 1630 E TRILBY RD OWNER: MATTHEW ALLDREDGE 1702 E TRILBY RD SheetTIMBER LARK RESIDENTIALThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 29 KEYMAP NORTH ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 GR1 GRADING PLAN9 GR1 GR2 GR3 MATCHLINE SEE SHEET GR2LEGEND: ST 1.A DETAILED LOT GRADING PLAN SHALL BE PROVIDED AT THE TIME OF BUILDING PERMIT TO ENSURE COMPLIANCE WITH LOT CERTIFICATION REQUIREMENTS. THIS MAY REQUIRE RETAINING WALLS OR EXPOSED FOUNDATIONS TO MEET SLOPE REQUIREMENTS. 2.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 3.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS UNLESS OTHERWISE NOTED. 5.THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM. 6.CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 7.ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 36.25 (36.25) 2.0% NOTES: PROPOSED SLOPES EXISTING SPOT ELEVATION PROPOSED SPOT ELEVATION PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE EXISTING CONTOUR PROPOSED CONTOUR PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER LODLIMITS OF DEVELOPMENT PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) 1.THE NATURAL HABITAT BUFFER ZONES ARE INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONES. NATURAL HABITAT BUFFER ZONES CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R RED WILLOWDRIVEIRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRUDUDUDUD57' ROW 51' ROW 57' ROW 52' ROW 20' EOC-EOC 20' EOC-EOC 57' ROW D DD XXXXXXXXXXXXXXXXXXXXXXXXXXX X X X X X X X X X X X X X X X X X X X X X X X OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHUSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST STLOT 6 LOT 7 TRACT H UDA&EAE LOT 1 TRACT O DE LOT 3 LOT 5 LOT 4 LOT 3 LOT 2 LOT 1 LOT 1 LOT 2 LOT 5 LOT 4 LOT 2LOT 10LOT 8LOT 7LOT 6LOT 5LOT 4LOT 3 LOT 9LOT 2 LOT 8LOT 5LOT 4LOT 3 LOT 6 LOT 7 LOT 10LOT 2 LOT 9 LOT 6 LOT 4 LOT 3 LOT 2 LOT 5 LOT 10 LOT 11 LOT 12 LOT 7 LOT 8 LOT 9 LOT 6 TRACT F UDA&EAE TRACT G DAE LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 9 LOT 7 LOT 8 LOT 10 LOT 10 LOT 9 LOT 8 LOT 7 LOT 3 LOT 5 LOT 4 LOT 1 LOT 2 LOT 6 LOT 6 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 9 LOT 7 LOT 8 LOT 10 LOT 10 LOT 9 LOT 8 LOT 7 LOT 3 LOT 5 LOT 4 LOT 1 LOT 2 TRACT R DE TRACT I UDA&EAE LOT 2 LOT 4 LOT 3 LOT 1 LOT 6 LOT 5 LOT 7 LOT 6 LOT 4 LOT 5 LOT 7 LOT 2 LOT 3 LOT 1 TRACT C DE TRACT B DELOT 1 LOT 3 LOT 4 LOT 5 LOT 6 LOT 11LOT 8 LOT 9 LOT 10 BLOCK 10 BLOCK 11 BLOCK 12 BLOCK 13 BLOCK 14 BLOCK 15 BLOCK 16 20' EOC-EOC BLOCK 8 BLOCK 19 BLOCK 20 BLOCK 2 BLOCK 3 STREET GSTREET IALLEY KALLEY LALLEY MALLEY OSTREET B STREET B STREET ISTREET A RED WILLOW DRIVE6' CONCRETE PAN (TYPICAL) UNDERGROUND STORM CHAMBERS5' SIDEWALK5' SIDEWALKDETENTION POND 2' CONCRETE PAN (TYPICAL) TRACT P DE 2 4 . 8 %25.5%26.2%21.9%22.3%6.2%21.1%23.3%25.3%26.7%3.7%5.2%4.4%4.1%2 . 3% 2. 9 % 2.1% 2. 3 % 3.2 % 2.3 % 2 . 4% PROPOSED 2' CURB CUT & SIDEWALK CHASE PROPOSED 2' CURB CUT & SIDEWALK CHASE PROPOSED 2' CURB CUT & SIDEWALK CHASE STMH A4-9N INLET A4-8N STMH A4-8N INLET A4-10N INLET A4-7N INLET A4-11N STMH A5 STMH A4 INLET A3-1 STMH A3 INLET A2 FES A1 CONNECTION A4-6N STMH B2 FES B1 IRMH A4 IRMH A3 IRMH A2 IR INLET A1 PROPOSED IRRIGATION LINE FES H2 CONNECTION TO EXISTING CONCRETE MANHOLE GRASS-LINED SWALE PROPOSED UNDERDRAIN INLET A4-1S INLET A4-1N LOT 10 LOT 9 LOT 8 LOT 7 LOT 6 LOT 5 LOT 4 LOT 159 LOT 157 LOT 156LOT 158 LOT 74LOT 75LOT 76LOT 77LOT 78LOT 79LOT 80 24" IRRIGATION24" IRRIGATION PROPOSED IRRIGATION OUTLET 2' CONCRETE PAN (TYPICAL)23.5%OWNER: RIC & CHERYL LEWIS 1790 E TRILBY RD OWNER: RIC & CHERYL LEWIS 1854 E TRILBY RD OWNER: SUSAN LEVINE REVOCABLE TRUST 1900 E TRILBY RD SheetTIMBER LARK RESIDENTIALThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 29 KEYMAP NORTH ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 GR2 GRADING PLAN10 GR1 GR2 GR3 LEGEND: ST 1.A DETAILED LOT GRADING PLAN SHALL BE PROVIDED AT THE TIME OF BUILDING PERMIT TO ENSURE COMPLIANCE WITH LOT CERTIFICATION REQUIREMENTS. THIS MAY REQUIRE RETAINING WALLS OR EXPOSED FOUNDATIONS TO MEET SLOPE REQUIREMENTS. 2.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 3.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS UNLESS OTHERWISE NOTED. 5.THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM. 6.CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 7.ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 36.25 (36.25) 2.0% NOTES: PROPOSED SLOPES EXISTING SPOT ELEVATION PROPOSED SPOT ELEVATION PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE EXISTING CONTOUR PROPOSED CONTOUR PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER LODLIMITS OF DEVELOPMENT PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) 1.THE NATURAL HABITAT BUFFER ZONES ARE INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONES. NATURAL HABITAT BUFFER ZONES MATCHLINE SEE SHEET GR1MATCHLINE SEE SHEET GR3CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R UD UD UD IRR IRR IRR IRR IRR IRRIRRIRRIRRIRRUDUDUDUDUDUDUDUDUDUDUDUD52' ROW 53' ROW 20' EOC-EOC 57' ROWFES XXXXXXXX X X X XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX X X X X OHU OHU OHU OHU OHU OHU OHU OHU OHU OHUCORONA AVETIMBERLINE ROADLOT 6 TRACT T DE TRACT N UDA&EAE TRACT M AE TRACT O DE LOT 3 LOT 4 LOT 3 LOT 1 LOT 2 LOT 5 LOT 4 LOT 5 LOT 1 LOT 2 LOT 1 LOT 2 LOT 5 LOT 4 LOT 3 LOT 13LOT 12 LOT 14 TRACT I UDA&EAE TRACT S DE TRACT J AE TRACT U DE TRACT K UDA&EAE TRACT L DE LOT 6 LOT 4 LOT 5 LOT 7 LOT 2 LOT 3 LOT 1 LOT 2 LOT 4 LOT 3 LOT 1 LOT 6 LOT 5 LOT 7 LOT 6 LOT 4 LOT 5 LOT 7 LOT 2 LOT 3 LOT 1 TRACT D DE LOT 1 LOT 3 LOT 4 LOT 5 LOT 9LOT 7 LOT 8 LOT 11LOT 10 LOT 12LOT 2LOT 11LOT 9 LOT 10 BLOCK 16 BLOCK 17 BLOCK 18 20' EOC-EOC BLOCK 22 BLOCK 20 BLOCK 21 BLOCK 4 BLOCK 4 STREET C CORONA AVENUEALLEY MALLEY NALLEY OALLEY PSTREET A RAIN GARDEN 1 RAIN GARDEN 2 DETENTION POND 2' CONCRETE PAN (TYPICAL) 2' CONCRETE PAN (TYPICAL)22.3%17.5%23.4%21.2% 1 7 . 4 % 25.5% 18.4% 12.5% 24.4%19.5%24.9%22.0%14.6%15.3%19.9%21.5%26.7%22.3%12. 5 %2.1%PROPOSED 2' CURB CUT & CONCRETE RUN-DOWN PROPOSED 2' CURB CUT & SIDEWALK CHASE OUTLET C4 FES C1 INLET D4 FES D1 PROPOSED 2' CURB CUT & SIDEWALK CHASE OUTLET E2 FES E1 IR INLET B4 IRMH B3 IR INLET B1 IRMH B2 PROPOSED IRRIGATION LINE FES G2 FES G1STORM DRAINFES H2 FES H1 STORM DRAIN FES F1 STORM DRAIN FES F2 INLET D2 INLET D3 STORM DRAIN STORM DRAIN INLET C2 INLET C3 2.8%4.5%RAIN GARDEN 2 REPLACE CONCRETE IRRIGATION STRUCTURE WITH PROPOSED INLET PROPOSED UNDERDRAIN PROPOSED IRRIGATION CHANNEL25.7%25.8%LOT 4 LOT 3 LOT 2 LINDEN PARK P.D.P., 1ST REPLAT LOT 1LOT 74 LOT 70 LOT 68 LOT 67 LOT 66 LOT 65 LOT 64 PROPOSED IRRIGATION OUTLET TIE TO EXISTING IRRIGATION CHANNEL 24" IRRIGATION 24" IRRIGATION16.0%4.5' SIDEWALK4.5' SIDEWALK4.5' SIDEWALK4.5' SIDEWALK8.6%2.3% OWNER: SUSAN LEVINE REVOCABLE TRUST 1900 E TRILBY RD OWNER: BARBARA KEEN LIVING TRUST 6417 S TIMBERLINE RD SheetTIMBER LARK RESIDENTIALThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 29 KEYMAP NORTH ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 GR3 GRADING PLAN11 GR1 GR2 GR3 LEGEND: ST 1.A DETAILED LOT GRADING PLAN SHALL BE PROVIDED AT THE TIME OF BUILDING PERMIT TO ENSURE COMPLIANCE WITH LOT CERTIFICATION REQUIREMENTS. THIS MAY REQUIRE RETAINING WALLS OR EXPOSED FOUNDATIONS TO MEET SLOPE REQUIREMENTS. 2.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 3.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS UNLESS OTHERWISE NOTED. 5.THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM. 6.CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 7.ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 36.25 (36.25) 2.0% NOTES: PROPOSED SLOPES EXISTING SPOT ELEVATION PROPOSED SPOT ELEVATION PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE EXISTING CONTOUR PROPOSED CONTOUR PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER LODLIMITS OF DEVELOPMENT PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) 1.THE NATURAL HABITAT BUFFER ZONES ARE INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONES. NATURAL HABITAT BUFFER ZONES MATCHLINE SEE SHEET GR2CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R LINDEN PARKP.D.P., 1ST REPLATLOT 18LOT 17LOT 16LOT 15LOT 14LOT 13LINDEN PARKP.D.P., 1ST REPLATSTA. = 10+00.00 (STREET E) STA. = 12+63.21 (STREET B) STREET B SEE SHEET R5 - R6 STREET B SEE SHEET R5 - R6 ∆ STREET E STREET ALOT 12 LOT 18 LOT 17 LOT 16 LOT 14 LOT 15 LOT 13 LOT 5 LOT 5 LOT 3 LOT 6 LOT 2 LOT 7 LOT 8 LOT 9 LOT 10 LOT 11 LOT 4LOT 3LOT 2 LOT 6LOT 1 LOT 4 TRACT ABLOCK 1 BLOCK 9BLOCK 730' FL - FL 53' ROW SEE THIS SHEET FOR EYEBROW PLAN & PROFILEROLL OVER CURB & GUTTER ROLL OVER CURB & GUTTER STOP SIGN w/ STREET NAME STORM DRAIN A PROPOSED CURB CUT & SIDEWALK CHASE 4.5' SIDEWALK 4.5' SIDEWALK 9' UTILITY EASEMENT 9' UTILITY EASEMENT 4925 4930 4935 4940 4945 4950 4955 4960 4965 4925 4930 4935 4940 4945 4950 4955 4960 4965 9+50 10+00 11+00 12+00 13+00 14+00 14+504937.374937.214937.714938.214938.714939.214939.714940.214940.714941.214941.714942.214942.714943.214943.714944.214944.714945.214945.712.20% -2.20%-2.20% 2.20% 2.00% 2.00%PVI STA = 9+86.17PVI ELEV = 4937.07PVI STA = 10+00.00PVI ELEV = 4937.37PVI STA = 10+13.00PVI ELEV = 4937.08PVI STA = 10+16.00PVI ELEV = 4937.02PVI STA = 10+19.83PVI ELEV = 4937.10PVI STA = 14+00.00PVI ELEV = 4944.71 STORM DRAIN STA.=10+10.00 PROPOSED GRADE @ ROAD CENTERLINE EXISTING GRADE @ ROAD CENTERLINE STREET E SEE THIS SHEET ∆ ∆ ∆ STREET A SEE SHEET R1 - R4 BLOCK 1 LOT 11 LOT 4 LOT 6 LOT 12 TRACT ALOT 18 LOT 17 LOT 16 LOT 14 LOT 15 LOT 13 LOT 5 BLOCK 1 BLOCK 9 BLOCK 1PROPOSED CURB CUT & SIDEWALK CHASE 4.5' SIDEWALK 4.5' SIDEWALK 9' UTILITY EASEMENT 9' UTILITY EASEMENT 4930 4935 4940 4945 4950 4955 4960 4965 4970 4930 4935 4940 4945 4950 4955 4960 4965 4970 9+50 10+00 11+00 12+00 12+504948.484948.634948.994949.824951.184952.474953.244953.434953.342.00% 2.00% 2.40% 1.60% 1.20%PVI STA = 10+00.00PVI ELEV = 4942.77PVI STA = 10+25.00PVI ELEV = 4943.27PVI STA = 10+50.00PVI ELEV = 4943.67PVI STA = 11+87.26PVI ELEV = 4945.79PVI STA = 12+12.26PVI ELEV = 4946.2950.0' VC PVI STA = 11+48.12 PVI ELEV = 4944.85 BCVS: 11+23.12BVCE: 4944.55ECVS: 11+73.12EVCE: 4945.45A.D. = 1.20 K = 41.72 PROPOSED GROUND EXISTING GROUND PROPOSED GRADE @ EYEBROW FLOWLINE EXISTING GRADE @ EYEBROW FLOWLINE SheetTIMBER LARK RESIDENTIALThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 29 MATCH LINE STA 14+50 STREET E & STREET A R1 PLAN AND PROFILESTREET E & STREET A12 NORTH 50 0 50 100 150 Feet (IN FEET) 1 inch = 50 ft. PROFILE SCALE:STAMATCH LINESEE SHEETR214+50KEYMAP EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3.MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4.EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6.CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8.PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK 6.PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING, SYMBOLS, AND SIGNS THEIR PLACEMENT SHALL BE APPROVED BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER. THE DEVELOPER SHALL PLACE TEMPORARY TABS, TAPE OR FLAGS DEPICTING ALIGNMENT AND LOCATION. CONTACT CITY OF FORT COLLINS TRAFFIC OPERATIONS AT 970-221-6630 FOR FIELD REVIEW. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE R2 R3 R4 R1 STREET E & STREET A EYEBROW PROFILE SCALE: CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R WEEPINGWILLOW DRIVEIRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRRIRRIRRIRRIRRSTREET A STA. = 20+70.26 (STREET A) STA. = 10+00.00 (ALLEY K) LOT 15 LOT 14 LOT 13 LOT 12 LINDEN PARK P.D.P., 1ST REPLAT LOT 11 LOT 10 LOT 9 LOT 8 LINDEN PARK P.D.P., 1ST REPLAT LINDEN PARK P.D.P., 1ST REPLAT LOT 7 LOT 6 STA. = 16+71.76 (STREET A) STA. = 11+31.50 (WEEPING WILLOW DRIVE) STA. = 19+38.26 (STREET A) STA. = 10+00.00 (STREET G) ALLEY K SEE SHEET R15 STREET G SEE SHEET R10 WEEPING WILLOW DRIVE SEE SHEETS R11 - R12 4.5' SIDEWALK 4.5' SIDEWALK LOT 1 LOT 8LOT 7LOT 6LOT 5LOT 4LOT 3 LOT 9LOT 2 LOT 9 LOT 10 LOT 1 LOT 2 LOT 6 LOT 7LOT 7 TRACT GDAETRACT F UDA&EAE TRACT B DE BLOCK 2 BLOCK 10 BLOCK 9 BLOCK 12BLOCK 11 LOT 6 LOT 19LOT 18 LOT 17 4.5' SIDEWALK 52' ROW 30' FL - FL 87.4° 92.6° 52' ROW 30' FL - FL 52' ROW 30' FL - FL ROLL OVER CURB & GUTTER VERTICAL CURB & GUTTERVERTICAL CURB & GUTTER ROLL OVER CURB & GUTTER 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 4925 4930 4935 4940 4945 4950 4955 4960 4965 4925 4930 4935 4940 4945 4950 4955 4960 4965 14+50 15+00 16+00 17+00 18+00 19+00 20+00 21+00 22+004945.714946.214946.714947.154947.434947.534947.474947.244946.934946.624946.304945.994945.684945.374945.054944.744944.434944.124943.804943.494943.184942.874942.554942.244941.934941.624941.304940.994940.684940.374940.05-1.25% 2.00% 120.0' VC HP ELEV = 4947.54 HP STA = 15+78.41 PVI STA = 15+64.57 PVI ELEV = 4948.00 BVCS: 15+04.57BVCE: 4946.80EVCS: 16+24.57EVCE: 4947.25A.D. = 3.25 K = 36.92 PROPOSED GROUND EXISTING GROUND PROPOSED GRADE @ ROAD CENTERLINE EXISTING GRADE @ ROAD CENTERLINE SheetTIMBER LARK RESIDENTIALThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 29MATCHLINESTA22+00STREET A R2 PLAN AND PROFILESTREET A13 NORTH 50 0 50 100 150 Feet (IN FEET) 1 inch = 50 ft. PROFILE SCALE:STAMATCH LINESEE SHEETR322+00STAMATCH LINESEE SHEET14+50R1KEYMAP EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3.MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4.EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6.CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8.PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK 6.PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING, SYMBOLS, AND SIGNS THEIR PLACEMENT SHALL BE APPROVED BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER. THE DEVELOPER SHALL PLACE TEMPORARY TABS, TAPE OR FLAGS DEPICTING ALIGNMENT AND LOCATION. CONTACT CITY OF FORT COLLINS TRAFFIC OPERATIONS AT 970-221-6630 FOR FIELD REVIEW. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE R2 R3 R4 R1 MATCHLINESTA14+50CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R RED WILLOWDRIVEIRR IRR IRRIRRIRRIRRIRRUDUDUDD F E SSTSTSTSTSTSTLINDEN PARK P.D.P., 1ST REPLAT LOT 6 LOT 5 LINDEN PARK P.D.P., 1ST REPLAT LOT 4 LOT 3 LOT 2 LINDEN PARK P.D.P., 1ST REPLAT LOT 1 STREET A 52' ROW TRACT I UDA&EAE LOT 4 LOT 5LOT 1 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 6LOT 2LOT 10 BLOCK 2 BLOCK 3 STA. = 23+24.26 (STREET A) STA. = 11+31.50 (RED WILLOW DRIVE) STA. = 24+53.76 (STREET A) STA. = 10+00.00 (ALLEY L) STA. = 25+83.26 (STREET A) STA. = 28+57.12 (STREET B & I) STA. = 27+14.51 (STREET A) STA. = 21+72.00 (ALLEY M) STA. = 29+21.76 (STREET A) STA. = 11+31.50 (CORONA AVENUE) STA. = 11+31.50 (ALLEY N) CORONA AVENUE SEE SHEET R4 ALLEY M SEE SHEET R16 STREET I SEE SHEETS R5 - R6 ALLEY N SEE SHEET R16 RED WILLOW DRIVE SEE SHEETS R13 - R14 ALLEY L SEE SHEET R15 CORONA AVEEXISTING 30" STORM DRAIN 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK TRACT L DE TRACT H UDA&EAE LOT 1 LOT 3LOT 2LOT 11LOT 8 LOT 9 LOT 10 LOT 13LOT 12 LOT 14 LOT 9 LOT 10 LOT 1 LOT 2 LOT 6 LOT 5 LOT 7 TRACT G DAE BLOCK 13BLOCK 14BLOCK 15LOT 2 LOT 3 LOT 1 LOT 6 LOT 5 LOT 7 LOT 2 LOT 3 LOT 1 BLOCK 18BLOCK 17BLOCK 1630' FL - FL 52' ROW 30' FL - FL 52' ROW 52' ROW30' FL - FL VERTICAL CURB & GUTTER ROLL OVER CURB & GUTTER VERTICAL CURB & GUTTER 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 4920 4925 4930 4935 4940 4945 4950 4955 4960 4920 4925 4930 4935 4940 4945 4950 4955 4960 22+00 23+00 24+00 25+00 26+00 27+00 28+00 29+00 30+00 31+00 31+504940.054939.744939.464939.284939.234939.294939.454939.614939.774939.944940.104940.264940.424940.594940.754940.914941.074941.244941.404941.564941.734941.894942.054942.214942.364942.414942.374942.234942.024941.814941.604941.384941.174940.964940.744940.534940.324940.104939.890.65% -1.25% -0.85% 100.0' VC HP ELEV = 4942.41 HP STA = 28+26.62 PVI STA = 28+33.38 PVI ELEV = 4942.59 BVCS: 27+83.35BVCE: 4942.27EVCS: 28+83.40EVCE: 4942.17A.D. = 1.50 K = 66.49 100.0' VC LP ELEV = 4939.23 LP STA = 22+99.03 PVI STA = 22+83.26 PVI ELEV = 4939.01 BCVS: 22+33.24BVCE: 4939.64ECVS: 23+33.28EVCE: 4939.34A.D. = 1.90 K = 52.63 PROPOSED GROUND EXISTING GROUND EXISTING 30" RCP STORM DRAIN STA.=23+32.80 INV.=4925.46 STORM DRAIN STA.=22+80.59 STORM DRAIN STA.=22+13.26 PROPOSED GRADE @ ROAD CENTERLINE EXISTING GRADE @ ROAD CENTERLINE SheetTIMBER LARK RESIDENTIALThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 29MATCHLINESTA22+00R3 PLAN AND PROFILESTREET A14 NORTH 50 0 50 100 150 Feet (IN FEET) 1 inch = 50 ft. PROFILE SCALE:STAMATCH LINESEE SHEETR431+50STAMATCH LINESEE SHEET22+00R2KEYMAP EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3.MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4.EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6.CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8.PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK 6.PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING, SYMBOLS, AND SIGNS THEIR PLACEMENT SHALL BE APPROVED BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER. THE DEVELOPER SHALL PLACE TEMPORARY TABS, TAPE OR FLAGS DEPICTING ALIGNMENT AND LOCATION. CONTACT CITY OF FORT COLLINS TRAFFIC OPERATIONS AT 970-221-6630 FOR FIELD REVIEW. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE STREET A MATCHLINESTA31+50R2 R3 R4 R1 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R IRR IRR IRR IRRIRRIRRIRRUDUDUDUDUDUDSTREET A 52' ROW TRACT D DE LOT 5 LOT 9LOT 7 LOT 8 LOT 11LOT 10 LOT 12LOT 6 TRACT L DE TIMBERLINE ROAD24" IRRIGATION LATERAL BLOCK 4 BLOCK 4 4.5' SIDEWALK 4.5' SIDEWALK 30' FL - FL CONNECT TO EXISTING TIMBERLINE ROAD STOP SIGN w/ STREET NAMES 9' UTILITY EASEMENT 9' UTILITY EASEMENT 15' UTILITY EASEMENT15' UTILITYEASEMENT4925 4930 4935 4940 4945 4950 4955 4960 4965 4925 4930 4935 4940 4945 4950 4955 4960 4965 31+50 32+00 33+00 34+00 35+00 36+004939.894939.684939.464939.254939.044938.824938.614938.404938.184937.974937.754937.544937.454937.564937.874938.35-0.85% 2.00%PVI STA = 35+26.88PVI ELEV = 4938.3890.0' VC LP ELEV = 4937.45 LP STA = 34+48.80 PVI STA = 34+66.88 PVI ELEV = 4937.18 BCVS: 34+21.88BVCE: 4937.57ECVS: 35+11.88EVCE: 4938.08A.D. = 2.85 K = 31.54 PROPOSED GROUND EXISTING GROUND 24" IRRIGATION STA.=32+63.55 PROPOSED GRADE @ ROAD CENTERLINE EXISTING GRADE @ ROAD CENTERLINE 4920 4925 4930 4935 4940 4945 4950 4955 4960 4920 4925 4930 4935 4940 4945 4950 4955 4960 9+50 10+00 11+00 12+004945.154944.614943.894942.984941.984941.684941.354940.534939.70PROPOSED GROUND EXISTING GROUND -2.20% -1.77% -4.0 0 % -2.20% 2.20% -3.30 %PVI STA = 9+78.12PVI ELEV = 4945.54PVI STA = 11+44.50PVI ELEV = 4941.54PVI STA = 11+11.67PVI ELEV = 4941.52PVI STA = 11+14.67PVI ELEV = 4941.45PVI STA = 11+31.50PVI ELEV = 4941.8275.0' VC PVI STA = 10+37.50 PVI ELEV = 4944.48 BVCS: 10+00BVCE: 4945.15EVCS: 10+75EVCE: 4942.98A.D. = 2.23 K = 33.63 PROPOSED GRADE @ ROAD CENTERLINE EXISTING GRADE @ ROAD CENTERLINEIRR U D UD UD FESCORONA AVENUE ALLEY N SEE SHEET R16 STREET A SEE SHEETS R1 - R4 STREET A SEE SHEETS R1 - R4LINDEN PARKP.D.P., 1ST REPLATLOT 3LOT 2LINDEN PARKP.D.P., 1STREPLATLOT 153' ROW 30' FL-FL LOT 7LOT 6TRACT J AE TRACT K UDA&EAE LOT 2LOT 3LOT 1LOT 6LOT 5LOT 7LOT 2LOT 3LOT 1STA. = 11+31.50 (CORONA AVENUE) STA. = 29+21.76 (STREET A) STA. = 11+31.50 (ALLEY N)LOT 2LOT 4LOT 3LOT 6LOT 4LOT 5BLOCK 16 BLOCK 17 BLOCK 18 LOT 7LOT 1LOT 13 LOT 12 LOT 14 BLOCK 3 LOT 1 LOT 3 LOT 2 BLOCK 4 CONNECT TO EXISTING PAVEMENT ROLL OVER CURB & GUTTER TRACT L DE 4.5' SIDEWALK 4.5' SIDEWALK 6' CONCRETE PAN STOP SIGN w/ STREET NAMES 9' UTILITY EASEMENT 9' UTILITY EASEMENT SheetTIMBER LARK RESIDENTIALThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 29MATCHLINESTA31+50STREET A R4 PLAN AND PROFILESTREET A & CORONA AVENUE15 NORTH 50 0 50 100 150 Feet (IN FEET) 1 inch = 50 ft. PROFILE SCALE:STAMATCH LINESEE SHEET31+50R3KEYMAP EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3.MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4.EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6.CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8.PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK 6.PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING, SYMBOLS, AND SIGNS THEIR PLACEMENT SHALL BE APPROVED BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER. THE DEVELOPER SHALL PLACE TEMPORARY TABS, TAPE OR FLAGS DEPICTING ALIGNMENT AND LOCATION. CONTACT CITY OF FORT COLLINS TRAFFIC OPERATIONS AT 970-221-6630 FOR FIELD REVIEW. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE PROFILE SCALE: NORTH CORONA AVENUEFALCON RIDGE DRIVER3 R4 R4 R2 R3 R1 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R IRRIRRIRRIRRIRRIRRUDUDUDDSTSTSTSTSTST ST STREET B STREET B STA. = 10+00.00 (STREET B & I) STA. = 15+62.51 (GOLDEN WILLOW DRIVE) STA. = 12+63.21 (STREET B & I) STA. = 14+31.00 (STREET E) STA. = 15+29.21 (STREET B & I) STA. = 15+62.50 (WEEPING WILLOW DRIVE) STA. = 17+95.21 (STREET B & I) STA. = 14+31.00 (STREET G) STA. = 19+27.71 (STREET B & I) STA. = 14+31.00 (ALLEY K) STA. = 21+81.71 (STREET B & I) STA. = 15+62.50 (RED WILLOW DRIVE) GOLDEN WILLOW DRIVE SEE SHEETS R8 - R9 STREET E SEE SHEET R1 - R4 RED WILLOW DRIVE SEE SHEETS R13 - R14 ALLEY K SEE SHEET R15 STREET G SEE SHEET R10 WEEPING WILLOW DRIVE SEE SHEETS R11 - R12 52' ROW 30' FL-FL ROLL OVER CURB & GUTTER VERTICAL CURB & GUTTER VERTICAL CURB & GUTTER ROLL OVER CURB & GUTTER EXISTING STORM DRAIN EXISTING STORM DRAIN MANHOLE LOT 4 LOT 1LOT 1 LOT 1LOT 4 LOT 2 LOT 11 LOT 12 LOT 2 LOT 11 LOT 12 LOT 1 LOT 2 LOT 3 LOT 4 LOT 10 LOT 9 LOT 8 LOT 7 LOT 8LOT 5LOT 4LOT 3 LOT 6 LOT 7 LOT 10LOT 2 LOT 9LOT 8LOT 5LOT 1 LOT 3 LOT 6LOT 2 LOT 7 LOT 6 LOT 5 LOT 2 LOT 3 LOT 7 LOT 6 LOT 8 LOT 9 BLOCK 10BLOCK 9BLOCK 1 BLOCK 6 BLOCK 7 BLOCK 8 TRACT F UDA&EAE 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 6' CONCRETE PAN 6' CONCRETE PAN 6' CONCRETE PAN 6' CONCRETE PAN PROPOSED CURB CUT & SIDEWALK CHASE 6' CONCRETE PAN STOP SIGN w/ STREET NAMES 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 4920 4925 4930 4935 4940 4945 4950 4955 4960 4920 4925 4930 4935 4940 4945 4950 4955 4960 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 20+00 21+00 22+004941.834939.634937.844937.134936.484936.064936.604937.184936.844936.194935.544934.894941.284940.734940.184939.084938.574938.164937.624937.454937.294936.974936.804936.644936.324936.164936.074936.134936.274936.444936.764936.924937.084937.204937.144937.004936.684936.524936.354936.034935.874935.704935.384935.224935.054934.734934.574934.40PROPOSED GRADE @ ROAD CENTERLINE EXISTING GRADE @ ROAD CENTERLINE -0.65%0.65% 2.20% -2.20% -0.65%PVI STA = 9+86.17PVI ELEV = 4941.53PVI STA = 10+00.00PVI ELEV = 4941.83100.0' VC HP ELEV = 4937.21 HP STA = 17+18.60 PVI STA = 17+18.60 PVI ELEV = 4937.37 BVCS: 16+68.60BVCE: 4937.04EVCS: 17+68.60EVCE: 4937.04A.D. = 1.30 K = 76.92 100.0' VC PVI STA = 11+77.56 PVI ELEV = 4937.93 BCVS: 11+27.56BVCE: 4939.03ECVS: 12+27.56EVCE: 4937.60A.D. = 1.55 K = 64.52 100.0' VC LP ELEV = 4936.05 LP STA = 14+90.88 PVI STA = 14+90.88 PVI ELEV = 4935.89 BCVS: 14+40.88BVCE: 4936.21ECVS: 15+40.88EVCE: 4936.21A.D. = 1.30 K = 76.92 PROPOSED GROUND EXISTING GROUND EXISTING 30" RCP STORM DRAIN STA.=21+89.58 INV.=4923.33 STORM DRAIN STA.=14+88.54 STORM DRAIN STA.=20+70.71 STORM DRAIN STA.=21+08.35 SheetTIMBER LARK RESIDENTIALThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 29MATCHLINESTA22+00R5 PLAN AND PROFILESTREET B16 NORTH 50 0 50 100 150 Feet (IN FEET) 1 inch = 50 ft. PROFILE SCALE:STAMATCH LINESEE SHEETR622+00KEYMAP EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3.MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4.EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6.CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8.PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK 6.PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING, SYMBOLS, AND SIGNS THEIR PLACEMENT SHALL BE APPROVED BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER. THE DEVELOPER SHALL PLACE TEMPORARY TABS, TAPE OR FLAGS DEPICTING ALIGNMENT AND LOCATION. CONTACT CITY OF FORT COLLINS TRAFFIC OPERATIONS AT 970-221-6630 FOR FIELD REVIEW. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE STREET B R5 R6 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R DSTSTSTSTSTSTSTSTSTSTSTSTSTSTREET ISTREET BSTA. = 25+99.12 (STREET B & I) STA. = 10+00.00 (STREET C) STA. = 28+57.12 (STREET B & I) STA. = 25+83.26 (STREET A) STREET A SEE SHEETS R1 - R4 STREET C SEE SHEET R7 STA. = 23+11.21 (STREET B & I) STA. = 14+31.00 (ALLEY L) ∆ RED WILLOW DRIVE SEE SHEETS R13 - R14 ALLEY L SEE SHEET R15 57' ROW 51' ROW 30' FL-FL VERTICAL CURB & GUTTER VERTICAL CURB & GUTTER VERTICAL CURB & GUTTER TRACT C DELOT 1 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 4 LOT 5 LOT 9LOT 7 LOT 8 LOT 10 LOT 10 LOT 9 LOT 8 LOT 7 LOT 3LOT 5 LOT 4 LOT 1LOT 2LOT 6 LOT 6 LOT 1 LOT 2 LOT 3 LOT 2 BLOCK 19BLOCK 19 BLOCK 3 TRACT O DE BLOCK 13 BLOCK 14 TRACT H UDA&EAE 4.5' SIDEWALK 4.5' SIDEWALK 36' FL - FL STOP SIGN w/ STREET NAMES 9' UTILITY EASEMENT 9' UTILITY EASEMENT PROPOSED CURB CUT & SIDEWALK CHASE 4920 4925 4930 4935 4940 4945 4950 4955 4960 4920 4925 4930 4935 4940 4945 4950 4955 4960 22+00 23+00 24+00 25+00 26+00 27+00 28+00 29+00 29+504934.244934.084933.924933.754933.594933.454933.474933.664934.024934.394934.774935.144935.524935.894936.274936.644937.024937.394937.774938.144938.524938.894939.274939.644940.024940.394940.81PROPOSED GRADE @ ROAD CENTERLINE EXISTING GRADE @ ROAD CENTERLINE 1.50% 2.20%-2.20% -0.65%PVI STA = 28+44.12PVI ELEV = 4940.68PVI STA = 28+57.12PVI ELEV = 4940.96PVI STA = 28+70.95PVI ELEV = 4940.6675.0' VC LP ELEV = 4933.44 LP STA = 23+35.17 PVI STA = 23+50.00 PVI ELEV = 4933.27 BCVS: 23+12.50BVCE: 4933.51ECVS: 23+87.50EVCE: 4933.83A.D. = 2.15 K = 34.88 STORM DRAIN STA.=23+36.73 PROPOSED GRADE EXISTING GRADE STSTSTSTSTSTSTSTSTREET I SEE SHEETS R5 - R6 STREET B SEE SHEETS R5 - R6 TRACT H UDA&EAE LOT 4 LOT 5 LOT 7 LOT 10 LOT 9 LOT 8 LOT 7 LOT 5 LOT 4LOT 6 LOT 6 LOT 1 LOT 2 LOT 3 BLOCK 19BLOCK 19 TRACT O DE BLOCK 13 BLOCK 14 RED WILLOW DRIVE SEE SHEETS R13 - R14 STREET C SEE SHEET R7 ∆ ∆ ∆ VERTICAL CURB & GUTTER VERTICAL CURB & GUTTER 4910 4915 4920 4925 4930 4935 4940 4945 4950 4910 4915 4920 4925 4930 4935 4940 4945 4950 9+50 10+00 11+00 12+00 12+504932.994933.114933.244933.474933.694933.914934.144934.454934.84PROPOSED GRADE @ EYEBROW FLOWLINE EXISTING GRADE @ EYEBROW FLOWLINE 0.50% 0.90%2.00%PVI STA = 10+00.00PVI ELEV = 4932.99PVI STA = 10+48.76PVI ELEV = 4933.23PVI STA = 12+24.66PVI ELEV = 4935.3275.0' VC PVI STA = 11+78.05 PVI ELEV = 4934.39 BCVS: 11+40.55BVCE: 4934.05ECVS: 12+15.55EVCE: 4935.14A.D. = 1.10 K = 67.96 PROPOSED GRADE EXISTING GRADE SheetTIMBER LARK RESIDENTIALThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 29 MATCH LINE STA 22+00 R6 PLAN AND PROFILESTREET B & STREET I17 NORTH 50 0 50 100 150 Feet (IN FEET) 1 inch = 50 ft. PROFILE SCALE:STAMATCH LINESEE SHEET22+00R5KEYMAP EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3.MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4.EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6.CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8.PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK 6.PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING, SYMBOLS, AND SIGNS THEIR PLACEMENT SHALL BE APPROVED BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER. THE DEVELOPER SHALL PLACE TEMPORARY TABS, TAPE OR FLAGS DEPICTING ALIGNMENT AND LOCATION. CONTACT CITY OF FORT COLLINS TRAFFIC OPERATIONS AT 970-221-6630 FOR FIELD REVIEW. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE STREET B & STREET I STREET B & STREET I EYEBROW PROFILE SCALE: R5 R6 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R STREET C STA. = 10+00.00 (STREET C) STA. = 25+99.12 (STREET B & I) STA. = 11+30.00 (STREET C) STA. = 19+14.00 (ALLEY M) STA. = 19+14.00 (ALLEY O) STA. = 13+38.50 (STREET C) STA. = 13+89.50 (ALLEY N) STA. = 13+89.50 (ALLEY P) ALLEY M SEE SHEET R16 STREET I SEE SHEETS R5 - R6 ALLEY N SEE SHEET R16 ALLEY P SEE SHEET R17 ALLEY O SEE SHEET R17STREET B SEE SHEETS R5 - R6 57' ROW36' FL-FL VERTICAL CURB & GUTTER VERTICAL CURB & GUTTER LOT 6 LOT 6 LOT 1 LOT 2 LOT 3 LOT 6 LOT 4 LOT 5 LOT 7 LOT 8 LOT 10 LOT 9 LOT 8 LOT 7 LOT 3 LOT 5 LOT 4 LOT 8 TRACT I UDA&EAE LOT 8 TRACT JAELOT 7TRACT K UDA&EAE LOT 2 LOT 4 LOT 3 LOT 1 LOT 6 LOT 4 LOT 5 LOT 7 LOT 2 LOT 4 LOT 3 LOT 1 LOT 6 LOT 4 LOT 5 LOT 7 TRACT MAETRACT O DE LOT 3 LOT 4 LOT 3 LOT 5 LOT 4 LOT 3 LOT 2 LOT 1 LOT 1 LOT 2 LOT 5 LOT 4 LOT 5 LOT 1 LOT 2 LOT 1 LOT 2 LOT 5 LOT 4 LOT 3 TRACT L DE TRACT O DEBLOCK 13BLOCK 14 BLOCK 15 BLOCK 16 BLOCK 18BLOCK 17 BLOCK 19BLOCK 20BLOCK 21BLOCK 22TRACT HUDA&EAETRACT N UDA&EAE ALLEY L SEE SHEET R15 TIMBERLINE ROAD4.5' SIDEWALK 4.5' SIDEWALK STOP SIGN w/ STREET NAMES PROPOSED TYPE 3 BARRICADE 9' UTILITY EASEMENT 9' UTILITY EASEMENT 4915 4920 4925 4930 4935 4940 4945 4950 4955 4915 4920 4925 4930 4935 4940 4945 4950 4955 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 20+004937.004936.594936.434936.274936.104935.944935.784935.624935.454935.294935.134934.974934.804934.644934.484934.324934.154933.994933.924933.994934.19PVI STA = 9+84.00PVI ELEV = 4936.65PVI STA = 10+00.00PVI ELEV = 4937.00PVI STA = 10+16.00PVI ELEV = 4936.65PVI STA = 15+06.14PVI ELEV = 4934.2575.0' VC LP ELEV = 4933.92 LP STA = 14+50.69 PVI STA = 14+58.64 PVI ELEV = 4933.77 BCVS: 14+21.14BVCE: 4934.02ECVS: 14+96.14EVCE: 4934.15A.D. = 1.65 K = 45.45 75.0' VC LP ELEV = 4933.92 LP STA = 14+50.69 PVI STA = 14+58.64 PVI ELEV = 4933.77 BCVS: 14+21.14BVCE: 4934.02ECVS: 14+96.14EVCE: 4934.15A.D. = 1.65 K = 45.45 PROPOSED GROUND @ ROAD CENTERLINE EXISTING GROUND @ ROAD CENTERLINE PROPOSED GRADE EXISTING GRADE 2.20%-2.20%-0.65% 1.00% STORM DRAIN STA.=14+50.69 2.00% 0.60%1.00%-0.60%PVI STA = 19+58.20PVI ELEV = 4935.50PVI STA = 19+38.74PVI ELEV = 4935.1175.0' VC HP ELEV = 4934.61 HP STA = 15+65.46 PVI STA = 15+56.21 PVI ELEV = 4934.75 BVCS: 15+18.71BVCE: 4934.37EVCS: 15+93.71EVCE: 4934.52A.D. = 1.60 K = 46.75 75.0' VC LOW PT ELEV = 4933.89 LOW PT STA = 17+17.47 PVI STA = 17+17.46 PVI ELEV = 4933.77 BVCS: 16+79.96BVCE: 4934.00EVCS: 17+54.96EVCE: 4934.00A.D. = 1.21 K = 62.06 FUTURE GROUND @ ROAD CENTERLINE SheetTIMBER LARK RESIDENTIALThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 29 R7 PLAN AND PROFILESTREET C18 NORTH 50 0 50 100 150 Feet (IN FEET) 1 inch = 50 ft. PROFILE SCALE: KEYMAP EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3.MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4.EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6.CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8.PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK 6.PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING, SYMBOLS, AND SIGNS THEIR PLACEMENT SHALL BE APPROVED BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER. THE DEVELOPER SHALL PLACE TEMPORARY TABS, TAPE OR FLAGS DEPICTING ALIGNMENT AND LOCATION. CONTACT CITY OF FORT COLLINS TRAFFIC OPERATIONS AT 970-221-6630 FOR FIELD REVIEW. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE STREET C R7 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R GOLDEN WILLOW DRIVE GOLDEN WILLOW DRIVELINDEN PARKP.D.P., 1ST REPLATLOT 19LOT 18LOT 17STA. = 15+62.51 (GOLDEN WILLOW DRIVE) STA. = 10+00.00 (STREET B & I) STREET B SEE SHEETS R5 - R6 53' ROW 30' FL-FL ROLL OVER CURB & GUTTER ROLL OVER CURB & GUTTER CONNECT TO EXISTING PAVEMENT TRACT E DUE LOT 4 LOT 4LOT 2 LOT 3LOT 1LOT 1 LOT 6LOT 2 LOT 3 LOT 5 LOT 7LOT 5 LOT 6 LOT 8LOT 9LOT 10LOT 11 LOT 1 LOT 2 LOT 5 BLOCK 7 6' CONCRETE PAN BLOCK 1 BLOCK 5 BLOCK 6 4.5' SIDEWALK 4.5' SIDEWALK LOT 2 LOT 4LOT 3LOT 1 TRACT Q OPEN SPACE LOT 14 89.6°90.4° 9' UTILITY EASEMENT 9' UTILITY EASEMENT 4930 4935 4940 4945 4950 4955 4960 4965 4970 4930 4935 4940 4945 4950 4955 4960 4965 4970 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 PROPOSED GRADE @ ROAD CENTERLINE EXISTING GRADE @ ROAD CENTERLINE -0.50% -0.65% -2.20%2.20% 0.65% -3.00 %PVI STA = 9+77.98PVI ELEV = 4951.00PVI STA = 15+43.51PVI ELEV = 4941.75PVI STA = 15+46.51PVI ELEV = 4941.68PVI STA = 15+49.51PVI ELEV = 4941.75100.0' VC PVI STA = 10+69.75 PVI ELEV = 4950.54 BVCS: 10+19.75BVCE: 4950.79EVCS: 11+19.75EVCE: 4949.04A.D. = 2.50 K = 40.00 100.0' VC PVI STA = 13+12.93 PVI ELEV = 4943.25 BCVS: 12+62.93BVCE: 4944.75ECVS: 13+62.93EVCE: 4942.92A.D. = 2.35 K = 42.55 4950.894949.594946.634943.804942.684942.034950.764950.534950.134948.884948.134947.384945.884945.134944.404943.344943.024942.844942.524942.364942.194941.874941.754941.91PROPOSED GRADE EXISTING GRADE SheetTIMBER LARK RESIDENTIALThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 29MATCHLINESTA16+00R8 PLAN AND PROFILEGOLDEN WILLOW DRIVE19 NORTH 50 0 50 100 150 Feet (IN FEET) 1 inch = 50 ft. PROFILE SCALE:STAMATCH LINESEE SHEETR916+00KEYMAP EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3.MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4.EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6.CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8.PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK 6.PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING, SYMBOLS, AND SIGNS THEIR PLACEMENT SHALL BE APPROVED BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER. THE DEVELOPER SHALL PLACE TEMPORARY TABS, TAPE OR FLAGS DEPICTING ALIGNMENT AND LOCATION. CONTACT CITY OF FORT COLLINS TRAFFIC OPERATIONS AT 970-221-6630 FOR FIELD REVIEW. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE GOLDEN WILLOW DRIVE R8 R9 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R LIDGOLDEN WILLOW DRIVE 52' ROW 30' FL-FL LOT 1 LOT 2 LOT 6LOT 5 BLOCK 7 BLOCK 6 TRACT E DUE 4.5' SIDEWALK 4.5' SIDEWALK STREET B SEE SHEETS R5 - R6 ROLL OVER CURB & GUTTER VERTICAL CURB & GUTTER PROPOSED TYPE 3 BARRICADE 4915 4920 4925 4930 4935 4940 4945 4950 4955 4915 4920 4925 4930 4935 4940 4945 4950 4955 16+00 17+00 18+00 19+00 20+00 21+00 22+00 PROPOSED GRADE @ ROAD CENTERLINE EXISTING GRADE @ ROAD CENTERLINE 0.65% -25.00%PVI STA = 16+95.47PVI ELEV = 4940.95FUTURE GRADE @ ROAD CENTERLINE 4942.244942.404942.56PROPOSED GRADE EXISTING GRADE 0.65% -7 . 4 8 % -5. 5 4 %PVI STA = 16+88.68PVI ELEV = 4942.65PVI STA = 21+95.47PVI ELEV = 4915.36165.0' VC HP ELEV = 4942.74 HP STA = 17+08.15 PVI STA = 17+77.45 PVI ELEV = 4943.23 BVCS: 16+94.95BVCE: 4942.69EVCS: 18+59.95EVCE: 4937.06A.D. = 8.13 K = 20.31 90.0' VC PVI STA = 20+21.21 PVI ELEV = 4925.01 BVCS: 19+76.21BVCE: 4928.37EVCS: 20+66.21EVCE: 4922.52A.D. = 1.94 K = 46.42 SheetTIMBER LARK RESIDENTIALThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 29MATCHLINESTA16+00R9 PLAN AND PROFILEGOLDEN WILLOW DRIVE20 NORTH 50 0 50 100 150 Feet (IN FEET) 1 inch = 50 ft. PROFILE SCALE:STAMATCH LINESEE SHEET16+00R8KEYMAP EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3.MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4.EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6.CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8.PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK 6.PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING, SYMBOLS, AND SIGNS THEIR PLACEMENT SHALL BE APPROVED BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER. THE DEVELOPER SHALL PLACE TEMPORARY TABS, TAPE OR FLAGS DEPICTING ALIGNMENT AND LOCATION. CONTACT CITY OF FORT COLLINS TRAFFIC OPERATIONS AT 970-221-6630 FOR FIELD REVIEW. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE GOLDEN WILLOW DRIVE R8 R9 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R STREET G STA. = 10+00.00 (STREET G) STA. = 19+37.76 (STREET A) STA. = 14+31.00 (STREET G) STA. = 17+95.21 (STREET B & I) STREET B SEE SHEETS R5 - R6 ALLEY K SEE SHEET R15 STREET A SEE SHEETS R1 - R4 STREET A SEE SHEETS R1 - R4 STREET B SEE SHEETS R5 - R6 52' ROW 30' FL-FL ROLL OVER CURB & GUTTER ROLL OVER CURB & GUTTER LOT 1 LOT 7 LOT 6 LOT 5 LOT 4 LOT 3 LOT 2 LOT 5 LOT 4 LOT 3 LOT 6 LOT 7 LOT 2LOT 6 LOT 4 LOT 3 LOT 2LOT 5 LOT 10 LOT 11 LOT 12LOT 7 LOT 8 LOT 9 LOT 6 TRACT F UDA&EAE LOT 1LOT 2LOT 3LOT 4LOT 5LOT 9 LOT 7LOT 8LOT 10 BLOCK 2 BLOCK 8 BLOCK 10 BLOCK 11 6' CONCRETE PAN 4.5' SIDEWALK 4.5' SIDEWALK STOP SIGN w/ STREET NAMES STOP SIGN w/ STREET NAMES 9' UTILITY EASEMENT 9' UTILITY EASEMENT 4920 4925 4930 4935 4940 4945 4950 4955 4960 4920 4925 4930 4935 4940 4945 4950 4955 4960 9+50 10+00 11+00 12+00 13+00 14+00 15+004943.334942.854942.454942.044941.644941.234940.834940.424940.024939.614939.214938.804938.404937.994937.594937.184936.784936.742.20% 2.20% -2.20% -1.62% -2.20%-2.20%PVI STA = 9+86.17PVI ELEV = 4943.03PVI STA = 10+00.00PVI ELEV = 4943.33PVI STA = 14+31.00PVI ELEV = 4936.87PVI STA = 10+13.00PVI ELEV = 4943.05PVI STA = 14+12.00PVI ELEV = 4936.58PVI STA = 14+15.00PVI ELEV = 4936.52PVI STA = 14+44.83PVI ELEV = 4936.57PROPOSED GROUND @ ROAD CENTERLINE EXISTING GROUND @ ROAD CENTERLINE PROPOSED GRADE EXISTING GRADE SheetTIMBER LARK RESIDENTIALThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 29 R10 PLAN AND PROFILESTREET G21 NORTH 50 0 50 100 150 Feet (IN FEET) 1 inch = 50 ft. KEYMAP EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3.MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4.EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6.CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8.PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK 6.PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING, SYMBOLS, AND SIGNS THEIR PLACEMENT SHALL BE APPROVED BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER. THE DEVELOPER SHALL PLACE TEMPORARY TABS, TAPE OR FLAGS DEPICTING ALIGNMENT AND LOCATION. CONTACT CITY OF FORT COLLINS TRAFFIC OPERATIONS AT 970-221-6630 FOR FIELD REVIEW. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE STREET G PROFILE SCALE: R10 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R WEEPING WILLOW DRIVE IRRIRRIRRFOWEEPING WILLOW DRIVE STA. = 11+31.50 (WEEPING WILLOW DRIVE) STA. = 16+71.76 (STREET A) STA. = 15+62.50 (WEEPING WILLOW DRIVE) STA. = 15+29.21 (STREET B & I) STREET A SEE SHEETS R1 - R4 STREET B SEE SHEETS R5 - R6 STREET A SEE SHEETS R1 - R4 STREET B SEE SHEETS R5 - R6 CONNECT TO EXISTING PAVEMENT LOT 14LOT 13LOT 12LINDEN PARKP.D.P., 1ST REPLATLOT 11LOT 10LINDEN PARKP.D.P., 1ST REPLAT53' ROW 30' FL-FL ROLL OVER CURB & GUTTER ROLL OVER CURB & GUTTER LOT 4 LOT 3 LOT 2LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 LOT 11 LOT 12 LOT 6 LOT 4 LOT 3 LOT 2LOT 5 LOT 2 LOT 2 LOT 8 LOT 6 LOT 7 LOT 1 LOT 1 LOT 1 LOT 1 BLOCK 9 BLOCK 10 BLOCK 2 BLOCK 8 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 6' CONCRETE PAN 92.6°87.4° LOT 19 LOT 18 BLOCK 1STOP SIGN w/ STREET NAMES STOP SIGN w/ STREET NAMES STOP SIGN w/ STREET NAMES 9' UTILITY EASEMENT 9' UTILITY EASEMENT 4925 4930 4935 4940 4945 4950 4955 4960 4965 4925 4930 4935 4940 4945 4950 4955 4960 4965 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+004946.454946.474945.804943.664939.914936.824946.724946.814946.714946.514946.324946.074945.444944.964944.374942.844941.914940.914938.934938.084937.394936.274935.874935.87-2.20% 2.20% -2.20% -2.20% -4.0 0 % 1.25%-1.00% -2.20%2.20% 2.20% -2.20% -1.00% 1.83%PVI STA = 10+00.00PVI ELEV = 4946.45PVI STA = 15+46.50PVI ELEV = 4935.80PVI STA = 15+62.50PVI ELEV = 4936.15PVI STA = 15+76.33PVI ELEV = 4935.84PVI STA = 15+79.33PVI ELEV = 4935.78PVI STA = 11+11.67PVI ELEV = 4946.35PVI STA = 11+14.67PVI ELEV = 4946.29PVI STA = 11+31.50PVI ELEV = 4946.66PVI STA = 15+82.33PVI ELEV = 4935.84PVI STA = 11+44.50PVI ELEV = 4946.3775.0' VC HP ELEV = 4946.81 HP STA = 10+49.47 PVI STA = 10+45.30 PVI ELEV = 4947.02 BVCS: 10+07.80BVCE: 4946.55EVCS: 10+82.80EVCE: 4946.64A.D. = 2.25 K = 33.33 165.0' VC PVI STA = 12+69.77 PVI ELEV = 4945.12 BVCS: 11+87.27BVCE: 4945.94EVCS: 13+52.27EVCE: 4941.82A.D. = 3.00 K = 55.00 75.0' VC PVI STA = 14+49.50 PVI ELEV = 4937.93 BCVS: 14+12BVCE: 4939.43ECVS: 14+87EVCE: 4937.10A.D. = 1.80 K = 41.67 PROPOSED GROUND @ ROAD CENTERLINE EXISTING GROUND @ ROAD CENTERLINE STORM DRAIN STA.=15+52.50 PROPOSED GRADE EXISTING GRADE 24" IRRIGATION STA.=10+07.25 SheetTIMBER LARK RESIDENTIALThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 29MATCHLINESTA16+00R11 PLAN AND PROFILEWEEPING WILLOW DRIVE22 NORTH 50 0 50 100 150 Feet (IN FEET) 1 inch = 50 ft. PROFILE SCALE:STAMATCH LINESEE SHEETR1216+00KEYMAP EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3.MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4.EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6.CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8.PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK 6.PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING, SYMBOLS, AND SIGNS THEIR PLACEMENT SHALL BE APPROVED BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER. THE DEVELOPER SHALL PLACE TEMPORARY TABS, TAPE OR FLAGS DEPICTING ALIGNMENT AND LOCATION. CONTACT CITY OF FORT COLLINS TRAFFIC OPERATIONS AT 970-221-6630 FOR FIELD REVIEW. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE WEEPING WILLOW DRIVE R11 R12 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R WEEPING WILLOW DRIVE 53' ROW 30' FL-FL LOT 2 LOT 8 LOT 6 LOT 7 LOT 1 BLOCK 7 BLOCK 8 4.5' SIDEWALK 4.5' SIDEWALK ROLL OVER CURB & GUTTER ROLL OVER CURB & GUTTER STREET B SEE SHEETS R5 - R6 STREET B SEE SHEETS R5 - R6 PROPOSED TYPE 3 BARRICADE 4905 4910 4915 4920 4925 4930 4935 4940 4945 4905 4910 4915 4920 4925 4930 4935 4940 4945 16+00 17+00 18+00 19+00 20+00 21+00 22+00 1.83%PVI STA = 16+81.33PVI ELEV = 4937.66EXISTING GROUND @ ROAD CENTERLINE FUTURE GROUND @ ROAD CENTERLINE 4936.634937.084937.54PROPOSED GRADE EXISTING GRADE 1.83% -8 . 0 0 %PVI STA = 21+95.14PVI ELEV = 4906.31198.0' VC HP ELEV = 4938.00 HP STA = 17+18.29 PVI STA = 17+80.33 PVI ELEV = 4939.48BVCS: 16+81.33BVCE: 4937.66EVCS: 18+79.33EVCE: 4931.56A.D. = 9.83 K = 20.14 PROPOSED GROUND @ ROAD CENTERLINE R12 PLAN AND PROFILEWEEPING WILLOW DRIVE23 NORTH 50 0 50 100 150 Feet (IN FEET) 1 inch = 50 ft. PROFILE SCALE:STAMATCH LINESEE SHEET16+00R11KEYMAP EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3.MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4.EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6.CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8.PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK 6.PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING, SYMBOLS, AND SIGNS THEIR PLACEMENT SHALL BE APPROVED BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER. THE DEVELOPER SHALL PLACE TEMPORARY TABS, TAPE OR FLAGS DEPICTING ALIGNMENT AND LOCATION. CONTACT CITY OF FORT COLLINS TRAFFIC OPERATIONS AT 970-221-6630 FOR FIELD REVIEW. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE WEEPING WILLOW DRIVE SheetTIMBER LARK RESIDENTIALThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 29MATCHLINESTA16+00R11 R12 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R IRRIRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR UD UD UD RED WILLOW DRIVE DST ST ST ST ST ST ST ST ST ST ST ST ST ST ST RED WILLOW DRIVE STA. = 11+31.50 (RED WILLOW DRIVE) STA. = 23+24.26 (STREET A) STA. = 15+62.50 (RED WILLOW DRIVE) STA. = 21+81.71 (STREET B & I) STREET A SEE SHEETS R2 - R4 STREET B SEE SHEETS R5 - R6 ALLEY L SEE SHEET R15 STREET B SEE SHEETS R5 - R6 STREET A SEE SHEETS R2 - R4 LINDEN PARKP.D.P., 1ST REPLATLOT 6LOT 557' ROW 36' FL-FL VERTICAL CURB & GUTTER VERTICAL CURB & GUTTER CONNECT TO EXISTING PAVEMENT ROLL OVER CURB & GUTTER ROLL OVER CURB & GUTTER EXISTING STORM DRAIN EXISTING STORM DRAIN MANHOLE TRACT O DELOT 2 LOT 10 BLOCK 2 LOT 9 LOT 10 LOT 9TRACT C DELOT 1 LOT 3 BLOCK 3 LOT 4LOT 5LOT 9 LOT 7LOT 8LOT 10 LOT 10LOT 9LOT 8LOT 7LOT 3 LOT 5LOT 4LOT 1 LOT 2 TRACT G DAE LOT 6 LOT 6 LOT 1LOT 2LOT 3 BLOCK 14 BLOCK 13 TRACT H UDA&EAE BLOCK 8 6' CONCRETE PAN 6' CONCRETE PAN 6' CONCRETE PAN 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK TRACT P DETRACT B DE STOP SIGN w/ STREET NAMES STOP SIGN w/ STREET NAMES STOP SIGN w/ STREET NAMES 9' UTILITY EASEMENT 9' UTILITY EASEMENT9' UTILITY EASEMENT 9' UTILITY EASEMENT 4915 4920 4925 4930 4935 4940 4945 4950 4955 4915 4920 4925 4930 4935 4940 4945 4950 4955 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+004939.324939.514939.634939.554939.394939.224939.064939.154938.944938.634938.324938.014937.704937.394937.084936.774936.464936.154935.854935.544935.234934.924934.614934.304934.084934.084934.17PROPOSED GRADE @ ROAD CENTERLINE EXISTING GRADE @ ROAD CENTERLINE 2.20% -2.20% -2.20%-2.20% 0.75%-0.65% 2.20% 2.20% -2.20% -1.24%PVI STA = 15+82.33PVI ELEV = 4934.05PVI STA = 15+46.50PVI ELEV = 4934.01PVI STA = 11+44.50PVI ELEV = 4939.00PVI STA = 11+14.67PVI ELEV = 4938.92PVI STA = 11+11.67PVI ELEV = 4938.98PVI STA = 11+31.50PVI ELEV = 4939.29PVI STA = 15+62.50PVI ELEV = 4934.36PVI STA = 15+79.33PVI ELEV = 4933.99PVI STA = 15+43.50PVI ELEV = 4934.0742.0' VC HP ELEV = 4939.63 HP STA = 10+02.44 PVI STA = 10+00.92 PVI ELEV = 4939.70 BVCS: 9+79.90BVCE: 4939.55EVCS: 10+21.94EVCE: 4939.57A.D. = 1.40 K = 30.00 STORM DRAIN STA.=15+52.49 SheetTIMBER LARK RESIDENTIALThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 29MATCHLINESTA16+00R13 PLAN AND PROFILERED WILLOW DRIVE24 NORTH 50 0 50 100 150 Feet (IN FEET) 1 inch = 50 ft. PROFILE SCALE:STAMATCH LINESEE SHEETR1416+00KEYMAP EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3.MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4.EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6.CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8.PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK 6.PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING, SYMBOLS, AND SIGNS THEIR PLACEMENT SHALL BE APPROVED BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER. THE DEVELOPER SHALL PLACE TEMPORARY TABS, TAPE OR FLAGS DEPICTING ALIGNMENT AND LOCATION. CONTACT CITY OF FORT COLLINS TRAFFIC OPERATIONS AT 970-221-6630 FOR FIELD REVIEW. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE RED WILLOW DRIVE R13 R14 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R IRR IRR IRR DDST ST STSTST STREET B SEE SHEETS R5 - R6 57' ROW 36' FL-FL VERTICAL CURB & GUTTER VERTICAL CURB & GUTTER RED WILLOW DRIVE EXISTING STORM DRAIN MANHOLE (TYPICAL) EXISTING STORM DRAIN (TYPICAL) STREET B SEE SHEETS R5 - R6 BLOCK 8 LOT 10 LOT 9 TRACT O DE 4.5' SIDEWALK 4.5' SIDEWALK TRACT P DE PROPOSED TYPE 3 BARRICADE 4905 4910 4915 4920 4925 4930 4935 4940 4945 4905 4910 4915 4920 4925 4930 4935 4940 4945 16+00 17+00 18+00 19+00 20+00 21+00 22+00 PROPOSED GRADE @ ROAD CENTERLINE EXISTING GRADE @ ROAD CENTERLINE 0.65% -25.01%PVI STA = 16+90.38PVI ELEV = 4934.76PVI STA = 16+94.74PVI ELEV = 4933.67FUTURE GRADE @ ROAD CENTERLINE 4934.334934.494934.66PROPOSED GRADE EXISTING GRADE 0.65% -6. 0 0 %PVI STA = 21+94.74PVI ELEV = 4912.65199.5' VC HP ELEV = 4934.97 HP STA = 17+32.82 PVI STA = 18+13.09 PVI ELEV = 4935.55 BVCS: 17+13.35BVCE: 4934.91EVCS: 19+12.82EVCE: 4929.57A.D. = 6.65 K = 30.00 R14 PLAN AND PROFILERED WILLOW DRIVE25 NORTH 50 0 50 100 150 Feet (IN FEET) 1 inch = 50 ft. PROFILE SCALE:STAMATCH LINESEE SHEET16+00R13KEYMAP EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3.MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4.EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6.CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8.PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK 6.PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING, SYMBOLS, AND SIGNS THEIR PLACEMENT SHALL BE APPROVED BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER. THE DEVELOPER SHALL PLACE TEMPORARY TABS, TAPE OR FLAGS DEPICTING ALIGNMENT AND LOCATION. CONTACT CITY OF FORT COLLINS TRAFFIC OPERATIONS AT 970-221-6630 FOR FIELD REVIEW. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE RED WILLOW DRIVE SheetTIMBER LARK RESIDENTIALThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 29MATCHLINESTA16+00R13 R14 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R DST ST ST ST ST ST ST ST ST ST ST ST ALLEY L STA. = 10+00.00 (ALLEY L) STA. = 24+53.76 (STREET A)STA. = 14+31.00 (ALLEY L) STA. = 23+11.21 (STREET B & I) STREET I SEE SHEETS R5 - R6 STREET C SEE SHEET R7 RED WILLOW DRIVE SEE SHEETS R13 - R14 STREET B SEE SHEETS R5 - R6 STREET A SEE SHEETS R1 - R4 20' EOC-TBC 10' CL-TBC EXISTING STORM DRAIN MANHOLE EXISTING STORM DRAIN LOT 2 LOT 1 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 6 LOT 6 LOT 1LOT 2LOT 3LOT 4LOT 5LOT 9 LOT 7LOT 8LOT 10 LOT 10LOT 9LOT 8LOT 7LOT 3 LOT 5LOT 4LOT 1 LOT 2 TRACT H UDA&EAE TRACT O DEBLOCK 3 BLOCK 13 BLOCK 14 SIDEWALK CHASE & CURB CUT ROLL OVER CURB & GUTTER STOP SIGN w/ STREET NAMES STOP SIGN w/ STREET NAMES 8' UTILITY EASEMENT 8' UTILITY EASEMENT 4915 4920 4925 4930 4935 4940 4945 4950 4955 4915 4920 4925 4930 4935 4940 4945 4950 4955 9+50 10+00 11+00 12+00 13+00 14+00 15+004940.124939.514939.104938.694938.284937.874937.464937.054936.654936.244935.834935.424935.014934.604934.204933.794933.384933.402.20% -2.20%-8.33% 8.33%2.20% -2.20%-2.00% -1.63%PVI STA = 9+86.17PVI ELEV = 4939.82PVI STA = 10+00.00PVI ELEV = 4940.12PVI STA = 10+13.00PVI ELEV = 4939.84PVI STA = 10+15.00PVI ELEV = 4939.67PVI STA = 14+18.00PVI ELEV = 4933.24PVI STA = 14+31.00PVI ELEV = 4933.53PVI STA = 14+44.83PVI ELEV = 4933.23PVI STA = 14+16.00PVI ELEV = 4933.08PVI STA = 14+05.50PVI ELEV = 4933.29PROPOSED GRADE @ ALLEY CENTERLINE EXISTING GRADE @ ALLEY CENTERLINE PROPOSED GRADE EXISTING GRADE 4920 4925 4930 4935 4940 4945 4950 4955 4960 4920 4925 4930 4935 4940 4945 4950 4955 4960 9+50 10+00 11+00 12+00 13+00 14+00 15+004941.684941.424941.864942.004941.834941.384940.884940.384939.884939.384938.884938.384937.884937.384936.884936.384935.884935.882.20% -2.20%-8.33% 2.00% -2.00% 8.33% 2.20%-2.20%PVI STA = 9+86.17PVI ELEV = 4941.37PVI STA = 10+00.00PVI ELEV = 4941.68PVI STA = 10+13.00PVI ELEV = 4941.39PVI STA = 10+15.00PVI ELEV = 4941.22PVI STA = 14+16.00PVI ELEV = 4935.56PVI STA = 14+18.00PVI ELEV = 4935.72PVI STA = 14+31.00PVI ELEV = 4936.01PVI STA = 14+44.83PVI ELEV = 4935.7180.0' VC HP ELEV = 4942.00 HP STA = 10+73.85 PVI STA = 10+73.85 PVI ELEV = 4942.40 BVCS: 10+33.85BVCE: 4941.60EVCS: 11+13.85EVCE: 4941.60A.D. = 4.00 K = 20.00 PROPOSED GRADE @ ALLEY CENTERLINE EXISTING GRADE @ ALLEY CENTERLINE PROPOSED GRADE EXISTING GRADE IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR STA. = 10+00.00 (ALLEY K) STA. = 20+70.26 (STREET A) STA. = 14+31.00 (ALLEY K) STA. = 19+27.71 (STREET B & I) STREET B SEE SHEETS R5 - R6 STREET G SEE SHEET R10 STREET A SEE SHEETS R1 - R4 STREET A SEE SHEETS R1 - R4 STREET B SEE SHEETS R5 - R6 ALLEY K 20' EOC-TBC 10' CL-TBC LOT 6 TRACT F UDA&EAE LOT 1LOT 2LOT 3LOT 4LOT 5LOT 9 LOT 7LOT 8LOT 10 LOT 10LOT 9LOT 8LOT 7LOT 3 LOT 5LOT 4LOT 1 LOT 2 LOT 8 LOT 7 LOT 6 LOT 5 LOT 9 LOT 8 LOT 5 LOT 6 LOT 7 LOT 9 LOT 6 TRACT G DAE LOT 10 LOT 10 BLOCK 8 BLOCK 11 BLOCK 12 BLOCK 2 ROLL OVER CURB & GUTTER SIDEWALK CHASE & CURB CUT TRACT P DETRACT B DE LOT 8STOP SIGN w/ STREET NAMES STOP SIGN w/ STREET NAMES 8' UTILITY EASEMENT 8' UTILITY EASEMENT 30' TRACT SheetTIMBER LARK RESIDENTIALThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 29 R15 PLAN AND PROFILESALLEY K & ALLEY L26 NORTH 50 0 50 100 150 Feet (IN FEET) 1 inch = 50 ft. PROFILE SCALE: KEYMAP EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3.MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4.EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6.CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8.PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK 6.PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING, SYMBOLS, AND SIGNS THEIR PLACEMENT SHALL BE APPROVED BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER. THE DEVELOPER SHALL PLACE TEMPORARY TABS, TAPE OR FLAGS DEPICTING ALIGNMENT AND LOCATION. CONTACT CITY OF FORT COLLINS TRAFFIC OPERATIONS AT 970-221-6630 FOR FIELD REVIEW. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE ALLEY LALLEY K PROFILE SCALE: R13 R13 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R LINDEN PARKP.D.P., 1ST REPLATLOT 4LOT 3LOT 2STREET I SEE SHEETS R5 - R6 ALLEY O SEE SHEET R17ALLEY M STREET C SEE SHEET R7 STREET A SEE SHEETS R2 - R4 STREET A SEE SHEETS R2 - R4 STA. = 21+72.00 (ALLEY M) STA. = 27+14.51 (STREET A) STA. = 21+72.00 (ALLEY O) STA. = 19+14.00 (ALLEY M) STA. = 11+31.25 (STREET C) STA. = 19+14.00 (ALLEY O) LOT 13 LOT 12 LOT 14 LOT 8LOT 2LOT 4LOT 3LOT 1LOT 6LOT 5LOT 7LOT 7 LOT 6 LOT 11 LOT 8 LOT 9 LOT 10 TRACT J AE LOT 8LOT 6LOT 4LOT 5LOT 7LOT 2LOT 3LOT 1TRACT M AE LOT 3LOT 5LOT 4LOT 3LOT 2LOT 1LOT 1LOT 2LOT 5LOT 4TRACT O DE BLOCK 19 BLOCK 20 BLOCK 15 BLOCK 16 TRACT C DEBLOCK 3 TRACT N UDA&EAELOT 2LOT 4LOT 3LOT 1LOT 6LOT 5LOT 7LOT 6BLOCK 19 BLOCK 21LOT 4LOT 5LOT 1LOT 2LOT 3TRACT I UDA&EAE ROLL OVER CURB & GUTTER STOP SIGN w/ STREET NAMES STOP SIGN w/ STREET NAMES STOP SIGN w/ STREET NAMES 5' UTILITY EASEMENT 5' UTILITY EASEMENT SIDEWALK CHASE & CURB CUT 4920 4925 4930 4935 4940 4945 4950 4955 4960 4920 4925 4930 4935 4940 4945 4950 4955 4960 11+00 12+00 13+00 14+00 PROPOSED GRADE @ ALLEY CENTERLINE EXISTING GRADE @ ALLEY CENTERLINE 4941.684941.354940.534939.704938.884938.054937.224936.404935.574934.754934.24-2.20% 8.33% 2.20% -2.20% -2.20% 2.20% -3.30 %PVI STA = 11+44.50PVI ELEV = 4941.54PVI STA = 13+73.50PVI ELEV = 4934.20PVI STA = 13+89.50PVI ELEV = 4934.55PVI STA = 11+11.67PVI ELEV = 4941.52PVI STA = 11+14.67PVI ELEV = 4941.45PVI STA = 11+31.50PVI ELEV = 4941.82PVI STA = 13+71.50PVI ELEV = 4934.04PROPOSED GRADE EXISTING GRADEIRRFESALLEY N LINDEN PARKP.D.P., 1ST REPLATLOT 3LOT 2LINDEN PARKP.D.P., 1STREPLATLOT 1CORONA AVENUE SEE SHEET R4 ALLEY P SEE SHEET R17 STREET C SEE SHEET R7 STREET A SEE SHEETS R2 - R4 STREET C SEE SHEET R7 STREET A SEE SHEETS R2 - R4 STA. = 11+31.50 (ALLEY N) STA. = 29+21.76 (STREET A) STA. = 11+31.50 (CORONA AVENUE) STA. = 13+89.50 (ALLEY N) STA. = 13+38.50 (STREET C) STA. = 13+89.50 (ALLEY P) STA. = 19+14.00 LOT 1 LOT 3 LOT 2 TRACT L DE LOT 7LOT 6LOT 4LOT 5LOT 7LOT 2LOT 3LOT 1LOT 2LOT 4LOT 3LOT 1LOT 6LOT 5LOT 7LOT 6LOT 3LOT 4LOT 5LOT 1LOT 2LOT 1LOT 2LOT 5LOT 4LOT 3TRACT O DE BLOCK 21 BLOCK 22 BLOCK 17 BLOCK 18 TRACT D DEBLOCK 4 TRACT M AE LOT 3LOT 1LOT 2LOT 5LOT 4LOT 13 LOT 12 LOT 14 LOT 8TRACT J AE LOT 6LOT 4LOT 5LOT 7LOT 2LOT 3LOT 1TRACT C DEBLOCK 3 BLOCK 20BLOCK 18 TRACT N UDA&EAETRACT K UDA&EAE ROLL OVER CURB & GUTTER SIDEWALK CHASE & CURB CUTSTOP SIGN w/ STREET NAMES STOP SIGN w/ STREET NAMES STOP SIGN w/ STREET NAMES 5' UTILITY EASEMENT 5' UTILITY EASEMENT SIDEWALK CHASE & CURB CUT 4920 4925 4930 4935 4940 4945 4950 4955 4960 4920 4925 4930 4935 4940 4945 4950 4955 4960 19+0020+0021+0022+0022+50 PROPOSED GRADE @ ALLEY CENTERLINE EXISTING GRADE @ ALLEY CENTERLINE 4935.664935.874936.554937.234937.914938.594939.274939.954940.634941.314941.772.20% -2.20% -8.33% 2.20% -2.20% 2.72 %PVI STA = 19+14.00PVI ELEV = 4935.90PVI STA = 19+30.00PVI ELEV = 4935.55PVI STA = 19+32.00PVI ELEV = 4935.38PVI STA = 21+72.00PVI ELEV = 4941.84PVI STA = 21+85.83PVI ELEV = 4941.53PVI STA = 21+59.00PVI ELEV = 4941.55PROPOSED GRADE EXISTING GRADE SheetTIMBER LARK RESIDENTIALThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 29 ALLEY N R16 PLAN AND PROFILEALLEY M & ALLEY N27 NORTH 50 0 50 100 150 Feet (IN FEET) 1 inch = 50 ft. PROFILE SCALE: KEYMAP EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3.MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4.EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6.CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8.PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK 6.PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING, SYMBOLS, AND SIGNS THEIR PLACEMENT SHALL BE APPROVED BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER. THE DEVELOPER SHALL PLACE TEMPORARY TABS, TAPE OR FLAGS DEPICTING ALIGNMENT AND LOCATION. CONTACT CITY OF FORT COLLINS TRAFFIC OPERATIONS AT 970-221-6630 FOR FIELD REVIEW. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE ALLEY M PROFILE SCALE: R16 R16 20.0' EOC-TBC 20.0' EOC-TBC 20.0' EOC-TBC 20.0' EOC-TBC CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R STA. = 19+14.00 (ALLEY O) STA. = 11+31.25 (STREET C) STA. = 19+14.00 (ALLEY M) STA. = 13+89.50 (ALLEY P) STA. = 13+38.50 (STREET C) STA. = 13+89.50 (ALLEY N) ALLEY M SEE SHEET R16 STREET B SEE SHEETS R5 - R6 ALLEY N SEE SHEET R16 STREET C SEE SHEET R7 STREET I SEE SHEETS R5 - R6 ALLEY OALLEY P∆∆ TRACT N UDA&EAE LOT 6 TRACT MAETRACT O DE LOT 3 LOT 4 LOT 3 LOT 5 LOT 4 LOT 3 LOT 2 LOT 1 LOT 1 LOT 2 LOT 5 LOT 4 LOT 5 LOT 1 LOT 2 LOT 1 LOT 2 LOT 5 LOT 4 LOT 3 LOT 10 LOT 9 LOT 8 LOT 7 LOT 5 LOT 4 LOT 2 LOT 3 LOT 1 LOT 6 LOT 5 LOT 7 LOT 2 LOT 3 LOT 1 LOT 6 LOT 5 LOT 7 BLOCK 15 BLOCK 16 BLOCK 17 BLOCK 18 BLOCK 19BLOCK 20BLOCK 21BLOCK 22TRACT I UDA&EAE TRACT JAETRACT K UDA&EAE TRACT O DE TRACT L DE BLOCK 14 STREET C SEE SHEET R7 STOP SIGN w/ STREET NAMES STOP SIGN w/ STREET NAMES 5' UTILITY EASEMENT5' UTILITY EASEMENT5' UTILITY EASEMENT5' UTILITY EASEMENT4915 4920 4925 4930 4935 4940 4945 4950 4955 4915 4920 4925 4930 4935 4940 4945 4950 4955 13+5014+0015+0016+0017+0018+0019+0019+50 PROPOSED GRADE @ ALLEY CENTERLINE EXISTING GRADE @ ALLEY CENTERLINE 4934.244934.324934.064933.884933.714933.534933.354933.174932.994932.824932.714932.724932.844933.084933.394933.714934.024934.334934.644934.954935.264935.594935.668.33% 2.20% -2.20% 2.20% -2.20% -8.33% -0.71% 1.25%PVI STA = 13+71.50PVI ELEV = 4934.04PVI STA = 13+73.50PVI ELEV = 4934.20PVI STA = 13+89.50PVI ELEV = 4934.55PVI STA = 14+05.50PVI ELEV = 4934.20PVI STA = 18+98.00PVI ELEV = 4935.55PVI STA = 19+14.00PVI ELEV = 4935.90PVI STA = 19+30.00PVI ELEV = 4935.55PVI STA = 19+32.00PVI ELEV = 4935.38106.6' VC LP ELEV = 4932.70 LP STA = 16+35.50 PVI STA = 16+50.00 PVI ELEV = 4932.46 BCVS: 15+96.72BVCE: 4932.84ECVS: 17+03.28EVCE: 4933.12A.D. = 1.96 K = 54.40 PROPOSED GRADE EXISTING GRADE SheetTIMBER LARK RESIDENTIALThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 29 R17 PLAN AND PROFILEALLEY O & ALLEY P28 NORTH 50 0 50 100 150 Feet (IN FEET) 1 inch = 50 ft. PROFILE SCALE: KEYMAP EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3.MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4.EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6.CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8.PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK 6.PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING, SYMBOLS, AND SIGNS THEIR PLACEMENT SHALL BE APPROVED BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER. THE DEVELOPER SHALL PLACE TEMPORARY TABS, TAPE OR FLAGS DEPICTING ALIGNMENT AND LOCATION. CONTACT CITY OF FORT COLLINS TRAFFIC OPERATIONS AT 970-221-6630 FOR FIELD REVIEW. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE ALLEY O & ALLEY P R17 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R PROPOSED CURB CUT & RUN DOWN FO HY DHY DC EC HY DLID S D CABLE ELEC ELEC ELEC BRKRE VAULT F.O. FO ELEC BRKRE D S D SELEC BRKREEE HY DF ES XXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXFOFOFOFOXXXWWWXXXXXXXXXXXXX X X X X X X X X X XXXXX OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHUSTSTSTSTSTSTSTST D S STUD IRR IRR IRRIRRIRR IRR IRR IRR IRR IRRIRRIRRIRRIRRIRRIRRUDUDUDUDUDUD2.32 ac. A1 1.19 ac. A2a 4.58 ac. A5 6.33 ac. A6 2.19 ac. A3 3.84 ac. A9 0.46 ac. A8 1.95 ac. A15 2.25 ac. A12 0.94 ac. A10 0.45 ac. A11 1.28 ac. A13 3.59 ac. A7 0.34 ac. A14 UNDERGROUND CHAMBERS DETENTION POND REQUIRED STORAGE VOLUME = 2.19 AC-FT WATER QUALITY VOLUME = 0.19 AC-FT PROVIDED VOLUME = 2.50 AC-FT OUTLET STRUCTURE RELEASE RATE = 40 CFS 2.77 A4 STREET A STREET ASTREET A STREET B STREET B STREET B STREET IALLEY MALLEY NALLEY OALLEY PGOLDEN WILLOW DRIVESTREET CSTREET EWEEPING WILLOW DRIVESTREET GALLEY KRED WILLOW DRIVEALLEY LCORONA AVENUE17.66 ac. OS1 TIMBERLINE ROADTRILBY ROAD CONNECTION TO EXISTING 30" STORM SEWER AT MANHOLE EX-4 (LINDEN PARK STORM OUTFALL) RAIN GARDEN 2 A2A A6 A7 A4 A3 A8 A9 A10 A11 A12 A13 A14 A15 A1 ### RAIN GARDEN 1 A5 0.69 ac. A2b TIMBERLINE ROADTRILBY ROAD PARAGON ESTATES NORTH CHANNEL PARAGON ESTATES LINDEN PARK SheetTIMBER LARK RESIDENTIALThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 29 NORTH ( IN FEET ) 0 1 INCH = 100 FEET 100 100 200 300 DR1 DRAINAGE PLAN29 PROPOSED CONTOUR PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED INLET A DESIGN POINT FLOW ARROW DRAINAGE BASIN LABEL DRAINAGE BASIN BOUNDARY PROPOSED SWALE SECTION 11 NOTES: 1.REFER TO THE PRELIMINARY DRAINAGE REPORT FOR TIMBER LARK, DATED JULY 9, 2021 FOR ADDITIONAL INFORMATION. A LEGEND: FOR DRAINAGE REVIEW ONLY NOT FOR CONSTRUCTION CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R