Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutTHE QUARRY BY WATERMARK - FDP210016 - SUBMITTAL DOCUMENTS - ROUND 2 - UTILITY PLANSPROSPECT ROADSHIELDS STREETLAKE STREET
PITKIN STREET
STUART STREET
HOBBIT ST.SHEELY DR
.
HILL POND R
D
.
CONNECTOR LOCAL STREET SECTION
MODIFIED - (HOBBIT STREET)EX. 8' PARKING LANE10' TRAVEL LANEEX. 10' TRAVEL LANEEXISTING DRIVE-OVER
CURB & GUTTER
VERTICAL
CURB & GUTTER
57' ROW
EX . 9'
UTIL.
ESMT.
9' UTIL.
ESMT.
4.5'
WALK
EX. 6'
PKWY.
36' -
6'
PKWY.
EX. 4.5'
WALK
8' PARKING LANECALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what's below.
before you dig.Call
R
SEPTEMBER 2021
UTILITY PLANS FOR
CONTACT INFORMATION
PROJECT TEAM:
Ripley Design, Inc.
419 Canyon Avenue, Suite 200
Fort Collins, CO. 80521
(970) 224-5828
Watermark Residential
111 Monument Circle, Suite 1500
Indianapolis, IN. 46204
(317) 853-5459
UTILITY CONTACT LIST: *
UTILITY COMPANY
* This list is provided as a courtesy reference only. Northern Engineering Services assumes no responsibility for
the accuracy or completeness of this list. In no way shall this list relinquish the Contractor's responsibility for
locating all utilities prior to commencing any construction activity. Please contact the Utility Notification Center of
Colorado (UNCC) at 811 for additional information.
PHONE NUMBER
Northern Engineering Services, Inc.
Danny Weber, PE
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
(970) 221-4158
Northern Engineering Services, Inc.
Bob Tessely, PLS
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
(970) 221-4158
E N G I N E E R N GI
EHTRON R N
E N G I N E E R N GI
EHTRON R N
PLANNER/
LANDSCAPE ARCHITECT
I hereby affirm that these final
construction plans were prepared
under my direct supervision, in
accordance with all applicable City
of Fort Collins and State of
Colorado standards and statutes,
respectively; and that I am fully
responsible for the accuracy of all
design. revisions, and record
conditions that I have noted on
these plans.
These plans have been reviewed by the City of Fort Collins for concept only. The review does not imply responsibility
by the reviewing department, the City of Fort Collins Engineer, or the City of Fort Collins for accuracy and correctness
of the calculations. Furthermore, the review does not imply that quantities of items on the plans are the final quantities
required. The review shall not be construed for any reason as acceptance of financial responsibility by the City of Fort
Collins for additional quantities of items shown that may be required during the construction phase.
DISCLAIMER STATEMENT:
CERTIFICATION STATEMENT:
PROJECT
LOCATION
VICINITY MAP
NORTH
DEVELOPER/APPLICANT
SITE ENGINEER
SURVEYOR
ORIGINAL FIELD SURVEY BY:
SUBSURFACE EXPLORATION BY:
PROJECT BENCHMARKS:
SHEET INDEX
THE QUARRY BY WATERMARK
GAS-----------------------Xcel Energy-----------------------------Al Ermer (970) 225-7869
ELECTRIC--------------City of Fort Collins Light & Power--Luke Unruh (970) 416-2724
CABLE-------------------Comcast----------------------------------Don Kapperman (970) 567-0245
TELECOM.-------------Qwest Local Network------------------Bill Johnson (970) 377-6401
WATER------------------City of Fort Collins Utilities-----------Matt Simpson (970) 416-2754
WASTEWATER-------City of Fort Collins Utilities-----------Matt Simpson (970) 416-2754
STORMWATER-------City of Fort Collins Utilities-----------Matt Simpson (970) 416-2754
W/WW INSPECTOR--City of Fort Collins Utilities-----------Jim McChesney (970) 556-8179
Earth Engineering Consultants, LLC.
"GEOTECHNICAL EXPLORATION REPORT SHIELDS MIXED USE DEVELOPMENT SOUTH OF HOBBIT STREET,
EAST OF SOUTH SHIELDS STREET"
Soilogic Project No. 1152075
Date: August 21, 2015
PROJECT DATUM: NAVD88
BENCHMARK 29-92 APPROXIMATE 300 FEET SOUTH OF WEST PROSPECT ROAD AND
SHIELDS STREET, ON THE NORTH END OF THE WEST BRIDGE PARAPET WALL.
ELEVATION: 5025.67
BENCHMARK 28-92 SOUTHWEST CORNER OF WEST PROSPECT ROAD AND CENTER
AVENUE, ON A WATER VALVE PIT.
ELEVATION: 5010.65
PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM.
SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED DATUM (PRIOR
CITY OF FORT COLLINS DATUM) FOR THEIR VERTICAL DATUMS.
IF NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) IS REQUIRED
FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29
UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) = NAVD88 - 3.17'.
BASIS OF BEARINGS
WEST LINE OF THE NORTHWEST QUARTER OF SECTION 23 AS BEARING NORTH 00°
01' 50" EAST (ASSUMED BEARING), AND MONUMENTED AS SHOWN ON DRAWING.
1 C 001 COVER SHEET
2 C 100 GENERAL & CONSTRUCTION NOTES
3 C 200 EXISTING CONDITIONS & DEMOLITION PLAN
4 C 300 EROSION CONTROL PLAN
5 C 301 EROSION CONTROL DETAILS
6 - 9 C 400 - C 403 PAVING PLAN
10 C 410 ADA ROUTING PLAN
11 C 420 INTERSECTION STRIPING PLAN
12 C 500 OVERALL GRADING PLAN
13 - 18 C 501 - C 506 GRADING PLAN
19 C 510 SUBGRADE PLAN
20 C 600 OVERALL UTILITY PLAN
21 - 26 C 601 - C 606 UTILITY PLAN
27 - 28 C 607 - C 608 BUILDING 1 ROOF DRAIN PLAN
29 C 610 SANITARY SEWER LINES A & A3 PLAN & PROFILE
30 C 611 SANITARY SEWER LINES B & B3 PLAN & PROFILE
31 C 612 SANITARY SEWER LINES C & D PLAN & PROFILE
32 C 620 STORM DRAIN 1 PLAN & PROFILE
33 C 621 STORM DRAINS 1-5 & 1-6 PLAN & PROFILE
34 C 622 STORM DRAINS 1-8 & 1-9 PLAN & PROFILE
35 C 623 STORM DRAINS 2, 2A & 3 PLAN & PROFILE
36 C 624 STORM DRAINS 4, 4-4A, & 4-4 PLAN & PROFILE
37 C 625 STORM DRAINS 5 & 5-2 PLAN & PROFILE
38 C 626 STORM DRAIN 6 & UNDERDRAIN PLAN & PROFILE
39 C 700 HISTORIC DRAINAGE EXHIBIT
40 C 701 DRAINAGE EXHIBIT
41 - 42 C 800 - C 801 WATER DETAILS
43 C 802 SANITARY SEWER & DRAINAGE DETAILS
44 - 46 C 803 - C 805 DRAINAGE DETAILS
47 - 48 C 806 - C 807 SITE DETAILS
C 001COVER SHEET1
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
TYPICAL SECTIONS
BEING A REPLAT OF LOTS 1-5, TRACT "A", TRACT "B", ALABASTER COURT, COROMANDEL CIRCLE AND STUART STREET, PULSE P.U.D. FILING ONE, LOCATED IN THE NORTHWEST
QUARTER OF SECTION 23, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH PRINCIPAL MERIDIAN, CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO
Intermill Land Surveying, Inc.Northern Engineering Services, Inc.
Company Project No. P-11-6963 Company Project No. 838-016
Date: April 2011 Date: July 2015
King Surveyors
Company Project No. 20190806
Date: January 2020
City of Fort Collins, CO
UTILITY PLAN APPROVAL
APPROVED:
CITY ENGINEER,APPROVED SHEETS DATE
APPROVED:
WATER & WASTEWATER UTILITY,APPROVED SHEETS DATE
APPROVED:
STORMWATER UTILITY,APPROVED SHEETS DATE
APPROVED:
PARK PLANNING & DEVELOPMENT,APPROVED SHEETS DATE
APPROVED:
TRAFFIC OPERATIONS,APPROVED SHEETS DATE
APPROVED:
ENVIRONMENTAL PLANNER,APPROVED SHEETS DATE
■ land planning ■ landscape architecture ■
■ urban design ■ entitlement ■
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what's below.
before you dig.Call
R
A. GENERAL NOTES
1.All materials, workmanship, and construction of public improvements shall meet or exceed the standards and specifications set forth in the Larimer
County Urban Area Street Standards and applicable state and federal regulations. Where there is conflict between these plans and the specifications, or
any applicable standards, the most restrictive standard shall apply. All work shall be inspected and approved by the City of Fort Collins.
2.All references to any published standards shall refer to the latest revision of said standard, unless specifically stated otherwise.
3.These public improvement construction plans shall be valid for a period of three years from the date of approval by the City of Fort Collins Engineer. Use
of these plans after the expiration date will require a new review and approval process by the City of Fort Collins prior to commencement of any work
shown in these plans.
4.The engineer who has prepared these plans, by execution and/or seal hereof, does hereby affirm responsibility to the City of Fort Collins, as beneficiary
of said engineer's work, for any errors and omissions contained in these plans, and approval of these plans by the City of Fort Collins Engineer shall not
relieve the engineer who has prepared these plans of all such responsibility. Further, to the extent permitted by law, the engineer hereby agrees to hold
harmless and indemnify the City of Fort Collins, and its officers and employees, from and against all liabilities, claims, and demands which may arise
from any errors and omissions contained in these plans.
5.All sanitary sewer, storm sewer and water line construction, as well as power and other "dry" utility installations, shall conform to the City of Fort Collins
standards and specifications current at the date of approval of the plans by the City of Fort Collins Engineer.
6.The type, size, location and number of all known underground utilities are approximate when shown on the drawings. It shall be the responsibility of the
Contractor to verify the existence and location of all underground utilities along the route of the work before commencing new construction. The
Contractor shall be responsible for unknown underground utilities.
7.The Contractor shall contact the Utility Notification Center of Colorado (UNCC) at 1-800-922-1987, at least 2 working days prior to beginning excavation
or grading, to have all registered utility locations marked. Other unregistered utility entities (i.e. ditch / irrigation company) are to be located by contacting
the respective representative. Utility service laterals are also to be located prior to beginning excavation or grading. It shall be the responsibility of the
Contractor to relocate all existing utilities that conflict with the proposed improvements shown on these plans.
8.The Contractor shall be responsible for protecting all utilities during construction and for coordinating with the appropriate utility company for any utility
crossings required.
9.If a conflict exists between existing and proposed utilities and/or a design modification is required, the Contractor shall coordinate with the engineer to
modify the design. Design modification(s) must be approved by the City of Fort Collins prior to beginning construction.
10.The Contractor shall coordinate and cooperate with the City of Fort Collins, and all utility companies involved, to assure that the work is accomplished in
a timely fashion and with a minimum disruption of service. The Contractor shall be responsible for contacting, in advance, all parties affected by any
disruption of any utility service as well as the utility companies.
11.No work may commence within any public storm water, sanitary sewer or potable water system until the Contractor notifies the utility provider. Notification
shall be a minimum of 2 working days prior to commencement of any work. At the discretion of the water utility provider, a pre-construction meeting may
be required prior to commencement of any work.
12.The Contractor shall sequence installation of utilities in such a manner as to minimize potential utility conflicts. In general, storm sewer and sanitary
sewer should be constructed prior to installation of the water lines and dry utilities.
13.The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the Water Utility.
14.A State Construction Dewatering Wastewater Discharge Permit is required if dewatering is required in order to install utilities or if water is discharged into
a storm sewer, channel, irrigation ditch or any waters of the United States.
15.The Contractor shall comply with all terms and conditions of the Colorado Permit for Storm Water Discharge (Contact Colorado Department of Health,
Water Quality Control Division, (303) 692-3590), the Storm Water Management Plan, and the Erosion Control Plan.
16.The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite
drainage facilities shall be the responsibility of the property owner(s).
17.Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must be submitted to
and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the
release of a certificate of occupancy for single family units. For commercial properties, certification shall be submitted to the Stormwater Utility
Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development
Agreement.
18.The City of Fort Collins shall not be responsible for any damages or injuries sustained in this Development as a result of groundwater seepage, whether
resulting from groundwater flooding, structural damage or other damage unless such damage or injuries are sustained as a result of the City of Fort
Collins failure to properly maintain its water, wastewater, and/or storm drainage facilities in the development.
19.All recommendations of the Final Drainage and Erosion Control Report for The Quarry by Watermark, dated September 1, 2021 by Northern Engineering
Services, Inc. shall be followed and implemented.
20.Temporary erosion control during construction shall be provided as shown on the Erosion Control Plan. All erosion control measures shall be maintained
in good repair by the Contractor, until such time as the entire disturbed areas is stabilized with hard surface or landscaping.
21.The Contractor shall be responsible for insuring that no mud or debris shall be tracked onto the existing public street system. Mud and debris must be
removed within 24 hours by an appropriate mechanical method (i.e. machine broom sweep, light duty front-end loader, etc.) or as approved by the the
City of Fort Collins street inspector.
22.No work may commence within any improved or unimproved public Right-of-Way until a Right-of-Way Permit or Development Construction Permit is
obtained, if applicable.
23.The Contractor shall be responsible for obtaining all necessary permits for all applicable agencies prior to commencement of construction. The
Contractor shall notify the the City of Fort Collins Inspector (Fort Collins - 221-6605) and the City of Fort Collins Erosion Control Inspector (Fort Collins -
221-6700) at least 2 working days prior to the start of any earth disturbing activity, or construction on any and all public improvements. If the City of Fort
Collins Engineer is not available after proper notice of construction activity has been provided, the Contractor may commence work in the Engineer
absence. However, the City of Fort Collins reserves the right not to accept the improvement if subsequent testing reveals an improper installation.
24.The Contractor shall be responsible for obtaining soils tests within the Public Right-of-Way after right of way grading and all utility trench work is complete
and prior to the placement of curb, gutter, sidewalk and pavement. If the final soils/pavement design report does not correspond with the results of the
original geotechnical report, the Contractor shall be responsible for a re-design of the subject pavement section or, the Contractor may use the City of
Fort Collins' default pavement thickness section(s). Regardless of the option used, all final soils/pavement design reports shall be prepared by a licensed
Professional Engineer. The final report shall be submitted to the Inspector a minimum of 10 working days prior to placement of base and asphalt.
Placement of curb, gutter, sidewalk, base and asphalt shall not occur until the City of Fort Collins Engineer approves the final report.
25.The contractor shall hire a licensed engineer or land surveyor to survey the constructed elevations of the street subgrade and the gutter flowline at all
intersections, inlets, and other locations requested by the the City of Fort Collins inspector. The engineer or surveyor must certify in a letter to the City of
Fort Collins that these elevations conform to the approved plans and specifications. Any deviations shall be noted in the letter and then resolved with the
City of Fort Collins before installation of base course or asphalt will be allowed on the streets.
26.All utility installations within or across the roadbed of new residential roads must be completed prior to the final stages of road construction. For the
purposes of these standards, any work except c/g above the subgrade is considered final stage work. All service lines must be stubbed to the property
lines and marked so as to reduce the excavation necessary for building connections.
27.Portions of Larimer County are within overlay districts. The Larimer County Flood Plain Resolution should be referred to for additional criteria for roads
within these districts.
28.All road construction in areas designated as Wild Fire Hazard Areas shall be done in accordance with the construction criteria as established in the Wild
Fire Hazard Area Mitigation Regulations in force at the time of final plat approval.
29.Prior to the commencement of any construction, the contractor shall contact the Local Entity Forester to schedule a site inspection for any tree removal
requiring a permit.
30.The Contractor shall be responsible for all aspects of safety including, but not limited to, excavation, trenching, shoring, traffic control, and security. Refer
to OSHA Publication 2226, Excavating and Trenching.
31.The Contractor shall submit a Construction Traffic Control Plan, in accordance with MUTCD, to the appropriate Right-of-Way authority. (The the City of
Fort Collins, Larimer County, Colorado), for approval, prior to any construction activities within, or affecting, the Right-of-Way. The Contractor shall be
responsible for providing any and all traffic control devices as may be required by the construction activities.
32.Prior to the commencement of any construction that will affect traffic signs of any type, the contractor shall contact the City of Fort Collins Traffic
Operations Department, who will temporarily remove or relocate the sign at no cost to the contractor, however, if the contractor moves the traffic sign
then the contractor will be charged for the labor, materials and equipment to reinstall the sign as needed.
33.The Contractor is responsible for all costs for the initial installation of traffic signing and striping for the Development related to the Development's local
street operations. In addition, the Contractor is responsible for all costs for traffic signing and striping related to directing traffic access to and from the
Development.
34.There shall be no site construction activities on Saturdays, unless specifically approved by the City of Fort Collins Engineer, and no site construction
activities on Sundays or holidays, unless there is prior written approval by the City of Fort collins.
35.The Contractor is responsible for providing all labor and materials necessary for the completion of the intended improvements, shown on these drawings,
or designated to be provided, installed, or constructed, unless specifically noted otherwise.
36.Dimensions for layout and construction are not to be scaled from any drawing. If pertinent dimensions are not shown, contact the Designer for
clarification, and annotate the dimension on the as-built record drawings.
37.The Contractor shall have, onsite at all times, one (1) signed copy of the approved plans, one (1) copy of the appropriate standards and specifications,
and a copy of any permits and extension agreements needed for the job.
38.If, during the construction process, conditions are encountered which could indicate a situation that is not identified in the plans or specifications, the
Contractor shall contact the Designer and the City of Fort Collins Engineer immediately.
39.The Contractor shall be responsible for recording as-built information on a set of record drawings kept on the construction site, and available to the
Larimer County's Inspector at all times. Upon completion of the work, the contractor(s) shall submit record drawings to the City of Fort Collins Engineer.
40.The Designer shall provide, in this location on the plan, the location and description of the nearest survey benchmarks (2) for the project as well as the
basis of bearings. The information shall be as follows:
PROJECT DATUM: NAVD88
BENCHMARK 29-92 APPROXIMATE 300 FEET SOUTH OF WEST PROSPECT ROAD AND SHIELDS STREET, ON THE NORTH END OF THE
WEST BRIDGE PARAPET WALL.
ELEVATION: 5025.67
BENCHMARK 28-92 SOUTHWEST CORNER OF WEST PROSPECT ROAD AND CENTER AVENUE, ON A WATER VALVE PIT.
ELEVATION: 5010.65
PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29
UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) FOR THEIR VERTICAL DATUMS.
IF NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION
SHOULD BE USED: NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) = NAVD88 - 3.17'.
BASIS OF BEARINGS
WEST LINE OF THE NORTHWEST QUARTER OF SECTION 23 AS BEARING NORTH 00° 01' 50" EAST (ASSUMED BEARING), AND
MONUMENTED AS SHOWN ON DRAWING.
41.All stationing is based on centerline of roadways unless otherwise noted.
42.Damaged curb, gutter and sidewalk existing prior to construction, as well as existing fences, trees, streets, sidewalks, curbs and gutters, landscaping,
structures, and improvements destroyed, damaged or removed due to construction of this project, shall be replaced or restored in like kind at the
Contractor's expense, unless otherwise indicated on these plans, prior to the acceptance of completed improvements and/or prior to the issuance of the
first Certificate of Occupancy.
43.When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street
condition shall be documented by the City of Fort Collins Construction Inspector before any cuts are made. Patching shall be done in accordance with
the City of Fort Collins Street Repair Standards. The finished patch shall blend in smoothly into the existing surface. All large patches shall be paved with
an asphalt lay-down machine. In streets where more than one cut is made, an overlay of the entire street width, including the patched area, may be
required. The determination of need for a complete overlay shall be made by the Larimer County Engineer and/or the City of Fort Collins Inspector at the
time the cuts are made.
44.Upon completion of construction, the site shall be cleaned and restored to a condition equal to, or better than, that which existed before construction, or
to the grades and condition as required by these plans.
45.Standard Handicap ramps are to be constructed at all curb returns and at all "T" intersections.
46.After acceptance by the City of Fort Collins, public improvements depicted in these plans shall be guaranteed to be free from material and workmanship
defects for a minimum period of two years from the date of acceptance.
47.The City of Fort Collins shall not be responsible for the maintenance of roadway and appurtenant improvements, including storm drainage structures and
pipes, for the following private streets: N.A.
48.Portions of the property are within FEMA Floodplain Zone AE, Fort Collins designated Floodplain and Fort Collins designated floodway. A Floodplain
Use Permit is required for any development within the floodplain. See Grading Plan for detailed notes concerning construction within the floodplain and
floodway.
49.Approved Variances are listed as follows:
CONSTRUCTION NOTES
A. Grading and Erosion Control Notes
1.The erosion control inspector must be notified at least twenty-four (24) hours prior to any construction on this site.
2.There shall be no earth-disturbing activity outside the limits designated on the accepted plans.
3.All required perimeter silt and construction fencing shall be installed prior to any land disturbing activity (stockpiling, stripping, grading, etc). All other
required erosion control measures shall be installed at the appropriate time in the construction sequence as indicated in the approved project schedule,
construction plans, and erosion control report.
4.At all times during construction, the Contractor shall be responsible for preventing and controlling on-site erosion including keeping the property
sufficiently watered so as to minimize wind blown sediment. The Contractor shall also be responsible for installing and maintaining all erosion control
facilities shown herein.
5.Pre-disturbance vegetation shall be protected and retained wherever possible. Removal or disturbance of existing vegetation shall be limited to the
area(s) required for immediate construction operations, and for the shortest practical period of time.
6.All soils exposed during land disturbing activity (stripping, grading, utility installations, stockpiling, filling, etc.) shall be kept in a roughened condition by
ripping or disking along land contours until mulch, vegetation, or other permanent erosion control BMPs are installed. No soils in areas outside project
street rights-of-way shall remain exposed by land disturbing activity for more than thirty (30) days before required temporary or permanent erosion control
(e.g. seed/mulch, landscaping, etc.) is installed, unless otherwise approved by the City/County.
7.In order to minimize erosion potential, all temporary (structural) erosion control measures shall:
a.Be inspected at a minimum of once every two (2) weeks and after each significant storm event and repaired or reconstructed as necessary in order
to ensure the continued performance of their intended function.
b.Remain in place until such time as all the surrounding disturbed areas are sufficiently stabilized as determined by the erosion control inspector.
c.Be removed after the site has been sufficiently stabilized as determined by the erosion control inspector.
8.When temporary erosion control measures are removed, the Contractor shall be responsible for the clean up and removal of all sediment and debris from
all drainage infrastructure and other public facilities.
9.The contractor shall immediately clean up any construction materials inadvertently deposited on existing streets, sidewalks, or other public rights of way,
and make sure streets and walkways are cleaned at the end of each working day.
10.All retained sediments, particularly those on paved roadway surfaces, shall be removed and disposed of in a manner and location so as not to cause
their release into any waters of the United States.
11.No soil stockpile shall exceed ten (10) feet in height. All soil stockpiles shall be protected from sediment transport by surface roughening, watering, and
perimeter silt fencing. Any soil stockpile remaining after thirty (30) days shall be seeded and mulched.
12.The stormwater volume capacity of detention ponds will be restored and storm sewer lines will be cleaned upon completion of the project and before
turning the maintenance over to the City/County or Homeowners Association (HOA).
13.City Ordinance and Colorado Discharge Permit System (CDPS) requirements make it unlawful to discharge or allow the discharge of any pollutant or
contaminated water from construction sites. Pollutants include, but are not limited to discarded building materials, concrete truck washout, chemicals, oil
and gas products, litter, and sanitary waste. The Contractor shall at all times take whatever measures are necessary to assure the proper containment
and disposal of pollutants on the site in accordance with any and all applicable local, state, and federal regulations.
14.A designated area shall be provided on site for concrete truck chute washout. The area shall be constructed so as to contain washout material and
located at least fifty (50) feet away from any waterway during construction. Upon completion of construction activities the concrete washout material will
be removed and properly disposed of prior to the area being restored.
15.Conditions in the field may warrant erosion control measures in addition to what is shown on these plans. The Contractor shall implement whatever
measures are determined necessary, as directed by the City.
B. Street Improvement Notes
1.All street construction is subject to the General Notes on the cover sheet of these plans as well as the Street Improvements Notes listed here.
2.A paving section design, signed and stamped by a Colorado licensed Engineer, must be submitted to the City of Fort Collins Engineer for approval, prior
to any street construction activity, (full depth asphalt sections are not permitted at a depth greater than 8 inches of asphalt). The job mix shall be
submitted for approval prior to placement of any asphalt.
3.Where proposed paving adjoins existing asphalt, the existing asphalt shall be saw cut, a minimum distance of 12 inches from the existing edge, to create
a clean construction joint. The Contractor shall be required to remove existing pavement to a distance where a clean construction joint can be made.
Wheel cuts shall not be allowed unless approved by the City of Fort Collins Engineer in Fort Collins.
4.Street subgrades shall be scarified the top 12 inches and re-compacted prior to subbase installation. No base material shall be laid until the subgrade has
been inspected and approved by the City of Fort Collins Engineer.
5.Ft. Collins only. Valve boxes and manholes are to be brought up to grade at the time of pavement placement or overlay. Valve box adjusting rings are not
allowed.
6.When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street
condition shall be documented by the Inspector before any cuts are made. Cutting and patching shall be done in conformance with Chapter 25,
Reconstruction and Repair. The finished patch shall blend smoothly into the existing surface. The determination of need for a complete overlay shall be
made by the City of Fort Collins Engineer. All overlay work shall be coordinated with adjacent landowners such that future projects do not cut the new
asphalt overlay work.
7.All traffic control devices shall be in conformance with these plans or as otherwise specified in M.U.T.C.D. (including Colorado supplement) and as per
the Right-of-Way Work Permit traffic control plan.
8.The Contractor is required to perform a gutter water flow test in the presence of the City of Fort Collins Inspector and prior to installation of asphalt.
Gutters that hold more than 1/4 inch deep or 5 feet longitudinally, of water, shall be completely removed and reconstructed to drain properly.
9.Prior to placement of H.B.P. or concrete within the street and after moisture/density tests have been taken on the subgrade material (when a full depth
section is proposed) or on the subgrade and base material (when a composite section is proposed), a mechanical "proof roll" will be required. The entire
subgrade and/or base material shall be rolled with a heavily loaded vehicle having a total GVW of not less than 50,000 lbs. and a single axle weight of at
least 18,000 lbs. with pneumatic tires inflated to not less that 90 p.s.i.g. "Proof roll" vehicles shall not travel at speeds greater than 3 m.p.h. Any portion of
the subgrade or base material which exhibits excessive pumping or deformation, as determined by the City of Fort Collins Engineer, shall be reworked,
replaced or otherwise modified to form a smooth, non-yielding surface. The City of Fort Collins Engineer shall be notified at least 24 hours prior to the
"proof roll." All "proof rolls" shall be preformed in the presence of an Inspector.
C. Traffic Signing and Pavement Marking Construction Notes
1.All signage and marking is subject to the General Notes on the cover sheet of these plans, as well as the Traffic Signing and Marking Construction Notes
listed here.
2.All symbols, including arrows, ONLYS, crosswalks, stop bars, etc. shall be pre-formed thermo-plastic.
3.All signage shall be per the City of Fort Collins Standards and these plans or as otherwise specified in MUTCD.
4.All lane lines for asphalt pavement shall receive two coats of latex paint with glass beads.
5.All lane lines for concrete pavement should be epoxy paint.
6.Prior to permanent installation of traffic striping and symbols, the Contractor shall place temporary tabs or tape depicting alignment and placement of the
same. Their placement shall be approved by the City of Fort Collins Traffic Engineer prior to permanent installation of striping and symbols.
7.Pre-formed thermo-plastic applications shall be as specified in these Plans and/or these Standards.
8.Epoxy applications shall be applied as specified in CDOT Standard Specifications for Road and Bridge Construction.
9.All surfaces shall be thoroughly cleaned prior to installation of striping or markings.
10.All sign posts shall utilize break-away assemblies and fasteners per the Standards.
11.A field inspection of location and installation of all signs shall be performed by the City of Fort Collins Traffic Engineer. All discrepancies identified during
the field inspection must be corrected before the 2-year warranty period will begin.
12.The Contractor installing signs shall be responsible for locating and protecting all underground utilities.
13.Special care shall be taken in sign location to ensure an unobstructed view of each sign.
14.Signage and striping has been determined by information available at the time of review. Prior to initiation of the warranty period,the City of Fort Collins
Traffic Engineer reserves the right to require additional signage and/or striping if the City of Fort Collins Traffic Engineer determines that an unforeseen
condition warrants such signage according to the MUTCD or the CDOT M and S Standards. All signage and striping shall fall under the requirements of
the 2-year warranty period for new construction (except fair wear on traffic markings).
15.Sleeves for sign posts shall be required for use in islands/medians. Refer to Chapter 14, Traffic Control Devices, for additional detail.
D. Storm Drainage Notes
1.The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite
drainage facilities shall be the responsibility of the property owner(s).
2.Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must by submitted to
and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the
release of a certificate of occupancy for single family units. For commercial properties, certification shall by submitted to the Stormwater Utility
Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development
Agreement.
E. Utility Notes
1.All waterline and sanitary sewer construction shall conform to the City of Fort Collins Utility standards and specifications current to date of construction.
2.The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the water utility.
3.Water mains shall be poly-wrapped D.I.P, or PVC with tracer wire.
4.HDPE pipe may be used for 1-1/2 and 2 inch water services. The pipe shall meet the standards of AWWA 901, NSF Standard 61 and ASTM. The
HDPE pipe shall be SDR 9 having a pressure rating of 200 psi. Stiffeners shall be used at all fittings and connections.
F. Floodplain Notes
1.Portions of this property are located in the Cityregulated, 100year Canal Importation floodplain/floodway as well as the FEMA Regulated Spring Creek
100year floodplain/floodway. Any development within the floodplain must comply with the safety regulations of Chapter 10 of City Municipal Code. The
Contractor shall obtain a Floodplain Use Permit from the City of Fort Collins and pay all applicable floodplain use permit fees prior to commencing any
construction activity (building of structures, grading, fill, detention ponds, bike paths, parking lots, utilities, landscaped areas, flood control channels, etc.)
within the City of Fort Collins floodplain limits as delineated on the Final Subdivision Plat
2.“Any construction activities, nonstructural development (bridges, sidewalks, culverts, vegetation, curbcuts, grading, etc.) in the regulatory floodway must
be preceded by a NoRise Certification, which must be prepared by a professional engineer licensed in the State of Colorado.
3.No storage of materials or equipment shall be allowed in the floodway, whether temporary (during construction) or permanent.
4.Any pedestrian bridges in the floodway that are not able to pass the 100 year flow are required to be “breakaway” and tethered.
C 100CONSTRUCTION NOTESGENERAL &2
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
V.P.
CABLE
F.O.
HY DVAULT
ELEC
VAULT
ELECVAULT
ELEC
T
E
S
S
MH
S
SSS
S
S
T S
H2O
TRAFFIC
VAULTT SVAULT
ELEC
S
VAULT
ELEC
VAULT
ELEC
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
ELEC
CONTROL
IRR
CONTROL
IRR
IRR W
V.P.
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
S
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
HY DS S
15" SS18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS
21" SS
21" SS21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS
8
"
S
S
8" SS 8" SS
8" SS
8" SS8" SS/ / / / / / / /EEEEEEEEEETTTTTTTTGGGGGGGGGGGWW W W W W W W
12" W12" W12" W12" W12" W12" WEFOEEEEEEEEEGGGGGGXXXXXXXXXXX30" W30" W30" W30" W30" W30" W30" W36" W36" W36" WFDC
FS E
E
E E
U
D
U
D
U
DUDUD
UD
UD UD UD UD UDSSWWW
S
S
UDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDD
F.O.
D
S
S
HY DMH
S
HY DMM
MH
ELEC
/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /XX30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W
XXXXXXXXXXXXSTSTSTSTSTSS
30" W
WINNE GRANT R/JOHNELLE S
1821 WALLENBERG DR
ERIKSEN CHRISTOPHER M
1825 WALLENBERG DR
MCCOY JOHN H/SHERRY P
1900 S SHIELDS ST
HILL POND CONDOMINIUMS
S
SSSSSSSSSSSSSS2
1
"
S
S
2
1
"
S
S
2
1
"
S
S
EXISTING 8" WATERLINE
EXISTING 21" CLAY
SANITARY SEWER
EXISTING 18" CLAY
SANITARY SEWER
EXISTING 8"
SANITARY SEWER
TO BE RELOCATED
EXISTING 12" WATERLINE
EXISTING 21" CLAY
SANITARY SEWER
EXISTING 30"
WATERLINE
FEMA 100-YR
HIGH RISK
FLOOD FRINGE
LANDMARK
APARTMENTS
TREES TO BE
REMOVED (TYP.)
EXIST
I
N
G
S
P
R
I
N
G
C
R
E
E
K
T
R
A
I
LS SHIELDS ST.HOBBIT ST.
CITY OF FORT COLLINS
100-YR FLOODPLAIN
FEMA 100-YR HIGH RISK
FLOOD FRINGE
EXISTING
UNDERDRAIN
EXISTING 40' ROW
EXISTING 40' ROWWALLENBERG DR
.
EXISTING 5' SIDEWALK
36' FL-FL
EXISTING
IRRIGATION
SERVICE
EXISTING FENCE TO
BE REMOVED
EXISTING12"
WATERLINE
40' UTILITY EASEMENT
TO BE VACATED
24' UTILITY &
ACCESS
EASEMENT TO BE
VACATED
28' UTILITY &
ACCESS EASEMENT
TO BE VACATED
28' UTILITY
EASEMENT TO BE
VACATED
15' UTILITY
EASEMENT TO BE
VACATED
40' UTILITY EASEMENT
TO BE VACATED
20' UTILITY EASEMENT
TO BE VACATED
10' UTILITY
EASEMENT TO BE
VACATED
8' UTILITY
EASEMENT TO BE
VACATED
20' DRAINAGE
EASEMENT TO BE
VACATED
20' UTILITY &
ACCESS EASEMENT
TO BE VACATED
8' UTILITY
EASEMENT TO
BE VACATED
15' UTILITY
EASEMENT TO
BE VACATED
40' UTILITY
EASEMENT TO
BE VACATED
8' UTILITY
EASEMENT TO BE
VACATED
8' UTILITY
EASEMENT TO
BE VACATED
DRAINAGE EASEMENT
REC. NO. 20200015504
20' UTILITY
EASEMENT TO
BE VACATED
120' DRAINAGE EASEMENT
TO BE VACATED
REC. NO. 87043454
25' TEMPORARY
CONSTRUCTION EASEMENT
TO BE VACATED
REC. NO. 90019873
80' DRAINAGE EASEMENT
TO BE VACATED
REC. NO. 87043454
15' SLOPE EASEMENT
TO BE VACATED
REC. NO. 90019873
28' UTILITY &
ACCESS EASEMENT
TO BE VACATED
EXISTING 8"
SANITARY SEWER
TO BE RELOCATED
EXISTING
UNDERDRAIN
54' ROW TO
BE VACATED
EXISTING ELECTRIC
VAULT (TYP.)EXIST
ING
8
'
TRA
IL
EXISTING CANAL
IMPORTATION
SPRIN
G
C
R
E
E
K
EASEMENT TO
BE VACATED
EXISTING SANITARY
SEWER MH TO BE
REMOVED
FEMA 100-YR
FLOODWAY
CITY OF FORT COLLINS
100-YR FLOODWAY
EXISTING
IRRIGATION METER
TO BE RELOCATED
W STUART ST.EXISTING PAVEMENT
TO BE REMOVED
EXISTING HOBBIT STREET ASPHALT
TO BE MILLED & OVERLAYED
PER CITY STANDARDS
PROPOSED
SAWCUT
EXISTING MANHOLE
TO BE REPLACED
EXISTING FH
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
C 200DEMOLITION PLANEXISTING CONDITIONS &3
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
NORTH
( IN FEET )
1 inch = ft.
Feet06060
60
120 180
EXISTING ELECTRIC E
LEGEND:
G
T
EXISTING STORM SEWER
EXISTING TELEPHONE
EXISTING GAS
EXISTING IRRIGATION BOX
EXISTING GAS METER
EXISTING TELEPHONE PEDESTAL
EXISTING TREES (TO REMAIN)
FIELD SURVEY BY:
SUBSURFACE EXPLORATION BY:
NOTES:
EXISTING SANITARY SEWER SS
EXISTING WATER W
EXISTING FENCE X
EXISTING WATER METER
EXISTING FIRE HYDRANT
EXISTING ELECTRIC VAULT
PROJECT BOUNDARY
EXISTING RIGHT-OF-WAY
EXISTING MAJOR CONTOUR
EXISTING MINOR CONTOUR
VAULT
ELEC
CONTROL
IRR
EXISTING TREES (TO BE REMOVED)
EXISTING CABLE CTV
EXISTING FIBER OPTIC FO
1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL,
REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL.
3.CONTRACTOR IS ENCOURAGED TO PERFORM DEMOLITION IN A MANNER THAT
MAXIMIZES SALVAGE, RE-USE, AND RECYCLING OF MATERIALS. THIS INCLUDES
APPROPRIATE SORTING AND STORING. IN PARTICULAR, DEMOLISHED CONCRETE,
ASPHALT, AND BASE COURSE SHOULD BE RECYCLED IF POSSIBLE.
4.ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE.
5.CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING
SITE SURVEY.
EXISTING OVERHEAD UTILITY OHE
Intermill Land Surveying, Inc.Northern Engineering Services, Inc.
Company Project No. P-11-6963 Company Project No. 838-016
Date: April 2011 Date: July 2015
King Surveyors
Company Project No. 20190806
Date: January 2020
Earth Engineering Consultants, LLC
Geotechnical Exploration Report Shields Mixed Use Development South of Hobbit
Street, East of South Shields Street.
Fort Collins, CO.
EEC Project No. 1152075
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
MHUDEE
U
D
U
D
U
DUDUD
UD
UD UD UD UD UD UD
S
S
UDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDD
D
MH
MM
MH
/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /XXXXXXXXXXXXXXXXXSTSTSTSTSTSTSTWINNE GRANT R/JOHNELLE S
1821 WALLENBERG DR
ERIKSEN CHRISTOPHER M
1825 WALLENBERG DR
MCCOY JOHN H/SHERRY P
1900 S SHIELDS ST
HILL POND CONDOMINIUMS
SSSSSSSSSSSSSSSSEEEEE
EEE
EEEEEEEEEEEEE
UDUDUDUD
UDEEEEEE
EE EEE E
FDC
FDCFDC FDC
FDCFDCFDCFDC
GG
ENYLOPLAST
DO NOT POLLUTE DRAINS TO WATERWAYS
NYLOPLAST
DO NOT POLLUTE DRAINS TO WATERWAYS
EE
E EEEEGGE E E E E EEG
GGGEE E EEEEEG
E
NYLOPLAST
DO NOT POLLUTE DRAINS TO WATERWAYS
UP
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBXXXBBBBBBBBBXXXXXXXIP
IP
IP
IP
IP
IP
IP
IP
IP
IP
IP
SF
SFSFSFSFRS
SF
RS
RS
RS
RS RS
RS
RS
RS
RS
RS
VTC
VTC
RS
SF
CWA
LOT 1
TRACT B
TRACT A
TRACT C
LOT 1
LOT 1
SPRI
N
G
C
R
E
E
K CANAL IMPORTATIONSS
IP
HOBBIT ST
SHIELDS ST.EXISTING SIDEWALKEXISTING SIDEWALKIP
IP
OP
RS
RS
IP
IP
IP IP
DETENTION
POND 2
DETENTION
POND 1
IP
IP
IP
IP
RS
SW SW
SW
SW
PROPOSED 4'
CONCRETE PAN PROPOSED 4'
CONCRETE PAN
PROPOSED 4'
CONCRETE PAN
PROPOSED 4'
CONCRETE PAN
PROPOSED 4'
CONCRETE PAN
PROPOSED 6'
CONCRETE PAN
PROPOSED 4'
CONCRETE PAN
PROPOSED 4'
CONCRETE PAN
PROPOSED 4'
CONCRETE PAN
PROPOSED
STORM DRAIN
PROPOSED 2'
CONCRETE PAN
PROPOSED 2'
CONCRETE PAN
PROPOSED 2'
CONCRETE PAN
PROPOSED
RAIN GARDEN
PROPOSED 4'
CONCRETE PAN
PROPOSED OUTLET
STRUCTURE
PROPOSED 2'
SIDEWALK
CHASE
PROPOSED 2'
SIDEWALK CHASE
PROPOSED 8"
STORM CULVERTS
PROPOSED 8"
STORM CULVERTS
PROPOSED 12"
STORM CULVERTS
PROPOSED 2'
SIDEWALK CHASE
FEMA 100-YR
HIGH RISK
FLOOD FRINGE
CITY OF FORT COLLINS
100-YR FLOODPLAIN
PROPOSED 2'
CONCRETE PAN
PROPOSED 2'
CONCRETE PAN
PROPOSED 2'
CONCRETE PAN
RAIN GARDEN
BIOMEDIA AREA
PROPOSED 4'
SIDEWALK
CULVERT
PROPOSED 2'
CONCRETE PAN
FEMA 100-YR
FLOODWAY
CITY OF FORT COLLINS
100-YR FLOODWAY
PROPOSED 2'
SIDEWALK CHASE
STORM DRAIN 1
SEE SHEET C 620
STORM DRAIN 1-8
SEE SHEET C 622
STORM DRAIN 1-9
SEE SHEET C 622
STORM DRAIN 4
SEE SHEET C 624
STORM DRAIN 4-4B
SEE SHEET C 624 STORM DRAIN 4-4A
SEE SHEET C 624
STORM DRAIN 5
SEE SHEET C 625
STORM DRAIN 5-2
SEE SHEET C 625
STORM DRAIN 2
SEE SHEET C 623
PROPOSED STORMTECH
CHAMBERS
STORM DRAIN 3
SEE SHEET C 623
STORM DRAIN 6
SEE SHEET C 626
PROPOSED
STORMTECH
CHAMBERS
PROPOSED 2'
SIDEWALK CHASE
STORM DRAIN 1-5
SEE SHEET C 621
STORM DRAIN 1-6
SEE SHEET C 621
SS
SS
SS
SS
FOREBAYSFSFSFSFSFSFSF
SFSFSFSFSF
SF
SF
LOC LOCLOC LOC
LOC
LOC
LOC
LOC
LOC
LOC
LOC
LOC
LOC
LOC
LOC LOC
LOC
LOC
L
O
C
L
O
C
LOC
LOC
IP
IP
IP
IP IP
IP
SF
SF
SF
SF
SF
SF
OP
SF
MU
MU
MU
IP
IPASHLAR DRW STU
A
R
T
S
T
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
C 300PLANEROSION CONTROL4
( IN FEET )
0
1 INCH = 60 FEET
60 60 120 180
NORTH
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
LEGEND:
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPOSED STORM INLET
TEMPORARY BMP'S
SEEDING AND MULCHING MU
CONCRETE WASHOUT AREA CWA
RSROCK SOCK
OUTLET PROTECTION OP
SILT FENCE SF SF
1.THE LOCATION OF EROSION CONTROL MEASURES HAS BEEN SHOWN FOR
REFERENCE ONLY. THE CONTRACTOR MAY ALTER THE NUMBER OR LOCATION
OF THE EROSION CONTROL MEASURES AS REQUIRED.
2.ALL OFF-SITE AREAS DISTURBED DURING CONSTRUCTION SHALL BE
RESEEDED WITH A DRYLAND SEED MIX, AS SPECIFIED IN THE CITY OF
LOVELAND STORMWATER SPECIFICATION SECTION 02377, PART 3, TABLE 1.
3.TOTAL DISTURBED AREA OF CONSTRUCTION = 5.91 ACRES
4.SWMP ADMINISTRATOR:
Person ________________________________
Company ________________________________
Address ________________________________
Phone ________________________________
5.CONTRACTOR TO PROVIDE VEHICLE TRACKING CONTROL FOR CONCRETE
WASHOUT AREA IF ACCESS IS OFF PAVEMENT. ANY MUD/DIRT TRACKED ONTO
CITY STREETS SHALL BE CLEANED IMMEDIATELY.
GENERAL NOTES:
1.IT SHOULD BE NOTED THAT ANY EROSION CONTROL PLAN SERVES ONLY AS A
GUIDELINE TO THE CONTRACTOR. STAGING AND/OR PHASING OF BEST
MANAGEMENT PRACTICES (BMPs) IS EXPECTED. ADDITIONAL AND/OR DIFFERENT
BMPs FROM THOSE ORIGINALLY DEPICTED MAY BE NECESSARY DURING
CONSTRUCTION DUE TO CHANGING SITE CONDITIONS OR AS REQUIRED BY LOCAL
AUTHORITIES.
2.THIS EROSION CONTROL PLAN IS SCHEMATIC IN NATURE. AS SUCH, GRAPHICAL
SYMBOLS MAY NOT BE TO SCALE, NOR ARE THEY NECESSARILY SHOWN IN THEIR
EXACT LOCATION.
3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL PERMITTING (CITY, STATE
DISCHARGE PERMIT, ETC.) AND COMPLIANCE WITH GOVERNING AUTHORITIES. IT
SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR (OR PERMIT HOLDER) TO
ENSURE EROSION CONTROL MEASURES ARE PROPERLY MAINTAINED AND
FOLLOWED.
4.CONTRACTOR SHALL IMPLEMENT THE APPROPRIATE EROSION CONTROL MEASURES
ACCORDING THE THE CONSTRUCTION SEQUENCING AND LEVEL OF SITE
STABILIZATION.
5.CONTRACTOR SHALL IMPLEMENT APPROPRIATE INLET PROTECTION FOR ALL
STORMWATER FACILITIES UNTIL SITE IS FULLY STABILIZED.
6.CONTRACTOR SHALL IMPLEMENT APPROPRIATE INLET PROTECTION FOR
DOWNSPOUT CONNECTIONS, TO THE STORM DRAIN SYSTEM, UNTIL CONNECTION IS
ESTABLISHED WITH DOWNSPOUT.
7.INLET PROTECTION SHALL BE ADAPTED, AS NECESSARY, TO THE SURROUNDING
SURFACE TYPE AND CONDITION (i.e., STAKE-DRIVEN WATTLES FOR BARE SOIL,
GRAVEL SOCKS FOR PAVEMENT, ETC.)
8.CONTRACTOR IS RESPONSIBLE FOR STABILIZING ALL SLOPES, PARTICULARLY
THOSE STEEPER THAN 6:1. CRIMP MULCHING, HYDRO MULCHING, EROSION MATS,
TEMPORARY IRRIGATION, AND ADDITIONAL WATTLES OR SILT FENCING MAY BE
NECESSARY TO ESTABLISH VEGETATIVE COVER AND STABILIZE THE SLOPE.
9.ADDITIONAL WATTLES, SILT FENCE, OR OTHER MEASURES, MAY BE NECESSARY TO
INSURE THAT EACH BUILDING PAD IS STABILIZED THROUGHOUT CONSTRUCTION. AT
NO TIME SHALL SEDIMENT BE ALLOWED TO CROSS THE PUBLIC SIDEWALKS.
10.CONTRACTOR SHALL IMPLEMENT APPROPRIATE PERIMETER PROTECTION FOR
AREAS DIRECTING DRAINAGE OFFSITE. PERIMETER PROTECTION SHALL BE
ADAPTED, AS NECESSARY, TO THE SURROUNDING SURFACE TYPE AND CONDITION
(i.e., STAKE-DRIVEN SEDIMENT CONTROL LOGS OR SILT FENCE FOR BARE SOIL, SAND
BAGS OR GRAVEL SOCKS FOR PAVEMENT, ETC.)
11.FUELING FACILITIES SHALL BE LOCATED AT LEAST ONE HUNDRED (100) FEET FROM
NATURAL BODY OF WATER, WETLAND, NATURAL DRAINAGE WAY OR MANMADE
DRAINAGE WAY. THE FUEL TANKS AND FUELING AREA MUST BE SET IN A
CONTAINMENT AREA THAT WILL NOT ALLOW A FUEL SPILL TO DIRECTLY FLOW, SEEP,
RUN OFF, OR BE WASHED INTO A BODY OF WATER, WETLAND OR DRAINAGE WAY.
12.CONSTRUCTION WASTE STORAGE (DUMPSTERS) AND PORTABLE SANITATION UNITS
(CONSTRUCTION TOILETS) SHALL BE LOCATED AT LEAST FIFTY (50) FEET FROM ANY
STORMWATER INLET, WETLAND, OR DRAINAGE WAY. SAID FACILITIES MUST BE SET
IN A CONTAINMENT AREA THAT WILL NOT ALLOW POLLUTANTS TO DIRECTLY FLOW,
SEEP, RUN OFF, OR BE WASHED INTO A BODY OF WATER, WETLAND OR DRAINAGE
WAY. DUMPSTERS SHALL BE LOCATED ON FLAT, STABLE GROUND, AND
CONSTRUCTION TOILETS SHALL BE STAKED DOWN.
13.THE CONTRACTOR AND ALL SUBCONTRACTORS WILL COOPERATE WITH THE CITY'S
CONSTRUCTION INSPECTORS BY CEASING OPERATIONS WHEN WINDS ARE OF
SUFFICIENT VELOCITY TO CREATE BLOWING DUST WHICH, IN THE INSPECTOR'S
OPINION, IS HAZARDOUS TO THE PUBLIC HEALTH AND WELFARE.
14.WHERE SEASONAL CONSTRAINTS (E.G., DURING SUMMER AND WINTER MONTHS)
INHIBIT PERMANENT SEEDING OPERATIONS, DISTURBED AREAS WILL BE TREATED
WITH MULCH AND MULCH TACKIFIER OR OTHER MATERIALS APPROVED BY EROSION
CONTROL STAFF TO PREVENT EROSION.
15.SEE LANDSCAPE PLANS FOR ADDITIONAL INFORMATION ON PLANTING,
REVEGETATION, HARDSCAPE AND OTHER PERMANENT SITE STABILIZATION
METHODS.
17.SLOPE PROTECTION SHALL BE PROVIDED FOR DISTURBED AREAS STEEPER THAN
6:1. SLOPE PROTECTION CAN BE ACCOMPLISHED THROUGH SLOPE TERRACING
USING A TRACKED VEHICLE, WINDROWING, HYDROMULCHING, EROSION CONTROL
FABRIC, OR ANY METHOD AS APPROVED BY THE ENGINEER OR INSPECTOR.
18.PERMANENT LID WATER QUALITY MEASURES WILL BE BUILT AS PART OF THE LAST
SEQUENCE OF CONSTRUCTION ACTIVITIES ON THE SITE.
EROSION CONTROL NOTES:
INLET PROTECTION IP
VEHICLE TRACKING CONTROL PAD VTC
SCOURSTOP SS
TABLE OF CONSTRUCTION SEQUENCE AND BMP APPLICATION
Project: THE QUARRY BY WATERMARK
CONSTRUCTION PHASE MOBILIZATION DEMOLITION GRADING
BEST MANAGEMENT PRACTICES (BMPS)
STRUCTURAL "INSTALLATION"
Silt Fence Barriers *
Straw Wattles *
Inlet Protection *
Vegetative
Temporary Seeding Planting
Mulching / Sealant
Permanent Seeding Planting
Sod Installation
Rolled Products : Netting / Blankets / Mats
Concrete Washout Area*
Rock Socks *
UTILITIES
INSTALLATION
FLAT WORK
INSTALLATION
VERTICAL
INSTALLATION LANDSCAPE DEMOBILIZATION
Vehicle Tracking Pad *
* All Temporary BMPs to be Removed once Construction is Complete
Any prior inlets that could use protecting
Any prior inlets that could use protecting
Anytime the site will sit dormant longer than 30 Days
Anytime the site will sit dormant longer than 30 Days
Anytime the site will sit dormant longer than 30 Days
SWSTRAW WATTLE
LIMITS OF CONSTRUCTION LOC LOC
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
C 301DETAILSEROSION CONTROL5
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
SF
1 OUTLET PROTECTION
2 CONCRETE WASHOUT AREA
3 TYPICAL ROCK SOCK
4 VEHICLE TRACKING CONTROL PAD
5 SILT FENCE
VTC
ROCK SOCK SECTION ROCK SOCK PLAN
ROCK SOCK JOINTING
GRADATION TABLE
SIEVE SIZE
MASS PERCENT
PASSING SQUARE
MESH SIEVES
NO. 4
2"100
1-1/2"90-100
1"20-55
3/4"0-15
3/8"0-5
MATCHES SPECIFICATIONS FOR NO. 4 COARSE AGGREGATE FOR
CONCRETE PER AASHTO M43. ALL ROCK SHALL BE FRACTURED FACE,
ALL SIDES
RS
CWA
AA
PLAN VIEW
SECTION A-A
2:1
OP
WQCV
9 CURB INLET PROTECTION
AT PIPE OUTLET AREAS OF STREAMS AND
DRAINAGE CHANNELS - DETAIL A
IN DIVERSION DITCH OR SMALL DITCH DRAINAGE WAY - DETAIL B
OUTSIDE OF STREAMS AND DRAINAGE CHANNELS - DETAIL C
ANCHOR DETAILS
PERIMETER ANCHOR TRENCH
JOINT ANCHOR TRENCH
INTERMEDIATE ANCHOR TRENCH
OVERLAPPING JOINT
WOOD STAKE DETAIL
MINIMUM THICKNESS 1"
USE 2x4 MATERIAL FOR STAKES
JOINT ANCHOR
TRENCH, TYP.
PERIMETER
ANCHOR
TRENCH, TYP.
TOP OF
CHANNEL BANK
TYPE OF BLANKET AS INDICATED IN PLAN VIEW, IN ALL DISTURBED AREAS OF
STREAMS AND DRAINAGE CHANNELS TO DEPTH "D" ABOVE CHANNEL INVERT.
BLANKET SHALL GENERALLY BE ORIENTED PARALLEL TO FLOW DIRECTION.
STAKING PATTERN SHALL MATCH BLANKET TYPE.
UNDISTURBED
SOIL
TYPE OF BLANKET,
INDICATED IN PLAN VIEW PER MANUFACTURER SPEC. OR TYPE 2 OR 3 STAKING
(MATCH SPECIFIED BLANKET TYPE) SEE THE STAKING
PATTERNS DETAIL ON NEXT SHEET
PERIMETER
ANCHOR TRENCH, TYP.
JOINT ANCHOR TRENCH, TYP.
COMPACTED
SUBGRADE
1
>3
THE BLANKET SHALL
BE EXTENDED TO THE
TOP OF CHANNEL
"D" 6"TOPSOIL"M"
OVERLAPPING JOINT, SEE
DETAIL ON THIS SHEET
STAGGER
OVERLAPS
PERIMETER ANCHOR TRENCH
SEE DETAIL ON THIS SHEET
PER MANUFACTURER SPEC.
OR TYPE 1 STAKING SEE
THE STAKING PATTERN
DETAIL ON NEXT SHEET
BLANKET SHALL BE
100% STRAW MIN.
DIVERSION DITCH
TYPICALLY AT
TOP OF SLOPE
6"TOPSOIL6" MIN.
(TYP.)
3" MIN.
(TYP.)
SINGLE EDGE
EROSION CONTROL
BLANKET (TYP.)
COMPACTED
BACKFILL (TYP.)
STAKE (TYP.)
TWO EDGES OF
TWO ADJACENT
ROLLS
LOOP FROM
MIDDLE OF
ROLL
FLOW 6"
3" MIN. 12"MIN. STAKING PATTERNS
SHALL BE IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATION. IF NO MANUFACTURER'S
SPECIFICATION IS AVAILABLE USE THE ACCEPTABLE STAKING PATTERN (AS SHOWN ABOVE)
PERIMETER ANCHOR
TRENCH OR JOINT
ANCHOR TRENCH, TYP.
STRAW-COCONUT
COCONUT OR EXCELSIOR
STRAW
ROLL WIDTH
"W" (TYP.)6'3'1/2 "W"
1/2 "W"
1/2 "W"
1/2 "W"
1/2 "W"4'3'2'ECB
EROSION CONTROL BLANKET TYPE
TYPE
STRAW*
STRAW-COCONUT
EXCELSIOR
COCONUT
CONTENT
-
30% MIN.
-
STRAW
CONTENT
100%
-
NETTING MIN.
DOUBLE/NATURAL
100%
-
-
EXCELSIOR
CONTENT
COCONUT --100%
* FOR OUTSIDE OF STREAMS AND DRAINAGE CHANNELS
DOUBLE/NATURAL
DOUBLE/NATURAL
DOUBLE/NATURAL
MAX.70%
IP
TURF REINFORCEMENT MAT - SCOUR STOP7
36" ANCHOR STRAP
BULLET ANCHOR
RECESSED LOCK
WASHER
TRANSITION MAT
TURF
REINFORCEMENT
MAT
ANCHOR PATTERN
ANCHOR ILLUSTRATION
MAX. 1"-2" DROP
FROM CULVERT FLOWLINE
ONTO SCOURSTOP MATS
PROFILE VIEW
SECTION VIEW AA
OUTLET AND CHANNEL SCOUR PROTECTION
(TRANSITION MATS)
DIRECTION OF FLOW
TURF REINFORCEMENT MAT
WIDTH OF
PROTECTION
LENGTH OF PROTECTION
D
D= CULVERT DIAMETER
TRAN
SI
TI
O
N
M
A
T
S
SOIL
C
O
V
E
R
A
A
CULVERT OUTLET PROTECTION - PLAN VIEW
INSTALL ANCHORS PER SCOURSTOP INSTALLATION GUIDELINES
MINIMUM DEPTH 24" IN COMPACTED, COHESIVE SOIL.
MINIMUM DEPTH 30" IN LOOSE, SANDY, OR WET SOIL
EXTRA ANCHORS AS NEEDED TO SECURE MAT TIGHTLY OVER SOIL
COVER
ABUT TRANSITIONS MATS TO END OF CULVERT OR CULVERT APRON.
ADJACENT MATS ABUT TOGETHER LATERALLY AND LONGITUDINALLY.
MINIMUM 8 ANCHORS PER MAT.
EXTRA ANCHORS AS NEEDED FOR LOOSE OR WET SOILS.
PROTECT BARE/ DISTURBED DOWNSTREAM
SOILS FROM EROSION WITH APPROPRIATE
SOIL COVER.
NOTE:
1.SCOUR STOP MAT PRODUCT UTILIZED FOR TURF REINFORCEMENT MAT DIMENSIONS. OTHER TURF REINFORCEMENT MAT
PRODUCTS EQUAL TO OR BETTER ALLOWED WITH APPROVAL OF THE ENGINEER AND CITY.
2.SEEDING AT OUTFALL OF STORM SEWER SHALL BE COMPLETED PRIOR TO INSTALLATION OF TURF REINFORCEMENT MAT.
SS
SEEDING TO OCCUR
PRIOR TO INSTALLATION
IP
FL
O
W
3'-4'
ADJACENT ROLLS SHALL
TIGHTLY ABUT
W1 NOTES:
INSTALLATION:
WHEN INSTALLING RUNNING LENGTHS OF WATTLES, BUTT
THE SECOND WATTLE TIGHTLY AGAINST THE FIRST, DO
NOT OVERLAP THE ENDS. STAKE THE WATTLES AT EACH
END AND FOUR FOOT ON CENTER. FOR EXAMPLE:
A 25 FOOT WATTLE USES 6 STAKES
A 20 FOOT WATTLE USES 5 STAKES
A 12 FOOT WATTLE USES 4 STAKES
STAKES SHOULD BE DRIVEN THROUGH THE MIDDLE OF
THE WATTLE. LEAVING 2 - 3 INCHES OF THE STAKE
PROTRUDING ABOVE THE WATTLE. A HEAVY SEDIMENT
LOAD WILL TEND TO PICK THE WATTLE UP AND COULD
PULL IT OFF THE STAKES IF THEY ARE DRIVEN DOWN TOO
LOW. IT MAY BE NECESSARY TO MAKE A HOLE IN THE
WATTLE WITH A PICK END OF YOUR MADDOX IN ORDER TO
GET THE STAKE THROUGH THE STRAW. WHEN STRAW
WATTLES ARE USED FOR FLAT GROUND APPLICATIONS,
DRIVE THE STAKES STRAIGHT DOWN; WHEN INSTALLING
WATTLES ON SLOPES, DRIVE THE STAKES
PERPENDICULAR TO THE SLOPE.
DRIVE THE FIRST END STAKE OF THE SECOND WATTLE AT
AN ANGLE TOWARD THE FIRST WATTLE IN ORDER TO HELP
ABUT THEM TIGHTLY TOGETHER. IF YOU HAVE DIFFICULTY
DRIVING THE STAKE INTO EXTREMELY HARD OR ROCKY
SLOPES, A PILOT BAR MAY BE NEEDED TO BEGIN THE
STAKE HOLE.
1"x 1" WOOD STAKES
18"-24"
BAILING WIRE OR
NYLON ROPE
WATTLE "A"WATTLE "B"
1'2'
TYP.
1'1'
W2 NOTES:
INSTALLATION:
STAKES SHOULD BE DRIVEN ACROSS
FROM EACH OTHER AND ON EACH
SIDE OF THE WATTLE. LEAVING 4"-6"
OF STAKE PROTRUDING ABOVE THE
WATTLE. BAILING WIRE OR NYLON
ROPE SHOULD BE TIED TO THE
STAKES ACROSS THE WATTLE.
STAKES SHOULD THEN BE DRIVEN
UNTIL THE BAILING WIRE OR NYLON
ROPE IS SUFFICIENTLY SNUG TO THE
WATTLE.
WHEN INSTALLING RUNNING LENGTHS
OF WATTLES, TO PREVENT SHIFTING,
BUTT THE SECOND WATTLE TIGHTLY
AGAINST THE FIRST. DO NOT
OVERLAP THE ENDS. STAKES
SHOULD BE DRIVEN 1 FT. FROM END,
ACROSS FROM AND ON EACH SIDE OF
WATTLE LEAVING 4"-6" OF STAKE
PROTRUDING ABOVE THE WATTLE.
BAILING WIRE OR NYLON ROPE
SHOULD BE TIED TO STAKES IN AN
HOUR GLASS FORMATION (FRONT TO
BACK OF WATTLE "A", ACROSS TO
FRONT OF WATTLE "B", ACROSS TO
BACK AND BACK TO FRONT OF
WATTLE "A"). STAKES SHOULD THEN
BE DRIVEN IN UNTIL BAILING WIRE OR
NYLON ROPE IS SUFFICIENTLY SNUG
TO THE WATTLE.
W1 & W2 INSTALLATION NOTES:
1. THE LOCATION AND LENGTH OF WATTLE IS DEPENDENT ON THE CONDITIONS OF EACH SITE.
2. WATTLES SHALL BE INSTALLED PRIOR TO ANY LAND-DISTURBING ACTIVITIES.
3. WATTLES SHALL CONSIST OF STRAW, COMPOST, EXCELSIOR, OR COCONUT FIBER.
4. NOT FOR USE IN CONCENTRATED FLOW AREAS.
5. THE WATTLES SHALL BE TRENCHED INTO THE GROUND A MINIMUM OF TWO (2) INCHES.
6. WATTLES SHALL BE INSTALLED PER MANUFACTURERS SPECIFICATIONS.
7. ON SLOPES, WATTLES SHOULD BE INSTALLED ON CONTOUR WITH A SLIGHT DOWNWARD ANGLE AT THE END OF THE ROW IN ORDER TO
PREVENT PONDING AT THE MID SECTION.
8. RUNNING LENGTHS OF WATTLES SHOULD BE ABUTTED FIRMLY TO ENSURE NO LEAKAGE AT THE ABUTMENTS.
9. SPACING - DOWNSLOPE:
VERTICAL SPACING FOR SLOPE INSTALLATIONS SHOULD BE DETERMINED BY SITE CONDITIONS. SLOPE GRADIENT AND SOIL TYPE ARE THE
MAIN FACTORS. A GOOD RULE OF THUMB IS:
1:1 SLOPES = 10 FEET APART
2:1 SLOPES = 20 FEET APART
3:1 SLOPES = 30 FEET APART
4:1 SLOPES = 40 FEET APART, ETC.
HOWEVER, ADJUSTMENTS MAY HAVE TO BE MADE FOR THE SOIL TYPE: FOR SOFT, LOAMY SOILS - ADJUST THE ROWS CLOSER
TOGETHER; FOR HARD, ROCKY SOILS - ADJUST THE ROWS FURTHER APART. A SECONDARY WATTLE PLACED BEHIND THE ABUTMENT OF TWO
WATTLES IS ENCOURAGED ON STEEP SLOPES OR WHERE JOINTS HAVE FAILED IN THE PAST.
10. STAKING: THE CITY RECOMMENDS USING WOOD STAKES TO SECURE THE WATTLES. 1/2" TO 5/8" REBAR IS ALSO ACCEPTABLE. BE SURE TO
USE A STAKE THAT IS LONG ENOUGH TO PROTRUDE SEVERAL INCHES ABOVE THE WATTLE: 18" IS A GOOD LENGTH FOR HARD, ROCKY SOIL.
FOR SOFT LOAMY SOIL USE A 24" STAKE.
4"-6" ABOVE WATTLE AFTER BAILING WIRE
OR NYLON ROPE IS ATTACHED. STAKES
NEED TO BE TAMPED UNTIL WIRE/ROPE IS
SNUG WITH WATTLE.
1"x 1" WOOD STAKES
18"-24"
ENDS OF ADJACENT WATTLES
SHALL BE TIGHTLY ABUTTED
TO PREVENT SEDIMENT BYPASS
W2 NOTE:
ONLY WATTLES MADE WITH COCONUT
FIBERS SHALL BE USED WHEN
INSTALLATION COMES IN CONTACT WITH A
WATER BODY.
SW
STRAW WATTLE6
8 INLET PROTECTION
10 CURB INLET PROTECTION
Scourstop Schedule
Storm
Line
Pipe
Diameter
(in)
Velocity
(cfs)
Transition Mat
W x L
2 & 2A 24 5*8'x8'
3 24 9.90 8'x8'
4 24 3.21 8'x8'
5 24 8.88 8'x8'
/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /UP
6' SIDEWALK
6' SIDEWALK6' SIDEWALK
9' SIDEWALK6' SIDEWALK
9' SIDEWALKS SHIELDS ST.HOBBIT ST.
6' SIDEWALKEXISTING SIDEWALKLOT 1 8' SIDEWALK9' SIDEWALK5' SIDEWALK6' SIDEWALK
5' SIDEWALK9' SIDEWALK5' SIDEWALK
4.5' SIDEWALK4.5' SIDEWALK
R15'
R25'
R15'
R3'R3'R3'R3'
R25'
R25'R75'
R7'
R7'R7'
R15'
R15'R15'R15'
R7'
R7'R3'
R7'
R7'
R15'
R10'
R15'
R7'
R15'
R7'
BLDG 6
BLDG 7
BLDG 2
BLDG 3
BLDG 4 BLDG 5
N:1448979.06
E:3113213.44
N:1449042.86
E:3113153.80
N:1449260.66
E:3113202.71
N:1449362.97
E:3113148.87
N:1449415.10
E:3113338.48
N:1449419.74
E:3113376.26
N:1449360.75
E:3113602.30
N:1449210.25
E:3113641.62
N:1449020.70
E:3113589.30
N:1449020.72
E:3113543.88
N:1449210.33
E:3113491.75
N:1449030.63
E:3113288.75
N:1449079.34
E:3113452.93
GARAGE 1
GARAGE 2
GARAGE 3 GARAGE 4
MATCH INTO EXISTING
SIDEWALK, CURB,
AND GUTTER
EXISTING RAMP TO BE
UPDATED TO CURRENT
CITY STANDARDS
EXISTING
STRIPING (TYP.)
EXISTING HOBBIT STREET ASPHALT
TO BE MILLED & OVERLAYED
PER CITY STANDARDS
P
P
D D
D
D
D
C
D
P
P
D
D
D
P
2 2
2 2
2
2
2
2
2 2
2
2
2 2
2
2
2
1 1
1
1
1
1
1
2
2
2
4
4
2
5 5
5
5 5
5
5
TRASH
ENCLOSURE
55
5
5
5
66
56
6
6
6
P
7
PROPOSED
LANDSCAPE
WALL
PROPOSED 30" VERTICAL
CURB & GUTTER
7
7
7
7
7
7
7
7
6 6
PROPOSED
LANDSCAPE
WALL
8
44 4 4 4
4
44
444
4 4
7
7
PROPOSED 2' PAN
w/ 6" CURBS4
4 4 4PARKING
STOP (TYP.)
11
1
1
1
P
1
1
2
2
2
2
2
2
2
2
PROPOSED
LANDSCAPE
WALL
7
7
5
4
2
3
7
2
3
5EXISTING ±10' LANEEXISTING ±6' BIKE LANE w/ BUFFEREXISTING ±10' LANEEXISTING ±10' LANEEXISTING ±6' BIKE LANE w/ BUFFEREXISTING ±10' LANE3
D
3
8.5'8.5'
8'
8'
8'
17'
9'8'9'
8'
9'
9'
8'
8'
8.5'
8.5'
8.5'
8.5'8.5'
5'
8'
8.5'
8.5'8.5'
17'
17'17'17'
8.5'
8.5'
17'
21'
17'
16.5'
15.5'15.5'
17'17'17'
17'
8.5'
8.5'
8.5'
8.5'
17'
15'
15'
17'
31'
FL-FL
26'
FL-FL
26'
FL-FL
26'
FL-FL
26'
FL-FL
28.3'
FL-FL
26' EMERGENCY ACCESS EASEMENT
26' EMERGENCY ACCESS EASEMENT
26' EMERGENCY ACCESS EASEMENT
31' EMERGENCY
ACCESS
EASEMENT
33' WATER
EASEMENT
16.5'
12'
8'
5'
8'
23'
26'
FL-FL
26' EMERGENCY ACCESS EASEMENT
10' UTILITY
EASEMENT 26'
FL-FLCOVERED
BIKE PARKING
D
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
C 400PAVING PLAN6
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
NORTH
( IN FEET )
1 inch = ft.
Feet03030
30
60 90
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
SEE SHEET C 402 SEE SHEET C 401EASEMENTS
NOTES:
1.SEE DETAIL SHEETS FOR ADDITIONAL INFORMATION REGARDING CURBS AND PAVEMENT SECTIONS.
2.PAVEMENT MARKINGS SHALL BE PER CITY OF FORT COLLINS STANDARDS AND PROJECT SPECIFICATION
MANUAL.
3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE
CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF
FORT COLLINS STREET REPAIR STANDARDS.
4.ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS,
SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS
PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE
DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO
THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY.
5.ALL PUBLIC CONCRETE PAVING SHALL BE 6" THICK.
6.REFER TO SITE AND LANDSCAPE PLANS (BY OTHERS) FOR ADDITIONAL INFORMATION RELATED TO
DECORATIVE PAVING, HARDSCAPES, AND OTHER SITE AMENITIES.
7.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE CITYREGULATED, 100YEAR CANAL IMPORTATION
FLOODPLAIN/FLOODWAY AS WELL AS THE FEMA REGULATED SPRING CREEK 100YEAR
FLOODPLAIN/FLOODWAY. ANY DEVELOPMENT WITHIN THE FLOODPLAIN MUST COMPLY WITH THE SAFETY
REGULATIONS OF CHAPTER 10 OF CITY MUNICIPAL CODE. THE DEVELOPER SHALL OBTAIN A FLOODPLAIN
USE PERMIT FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE PERMIT FEES
PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES, GRADING, FILL,
DETENTION PONDS, BIKE PATHS, PARKING LOTS, UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL
CHANNELS, ETC.) WITHIN THE CITY OF FORT COLLINS FLOODPLAIN LIMITS AS DELINEATED ON THE FINAL
SUBDIVISION PLAT
8.ANY CONSTRUCTION ACTIVITIES, NONSTRUCTURAL DEVELOPMENT (BRIDGES, SIDEWALKS, CULVERTS,
VEGETATION, CURBCUTS, GRADING, ETC.) IN THE REGULATORY FLOODWAY MUST BE PRECEDED BY A
NORISE CERTIFICATION, WHICH MUST BE PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN THE
STATE OF COLORADO.
9.NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE FLOODWAY, WHETHER
TEMPORARY (DURING CONSTRUCTION) OR PERMANENT.
8.ANY PEDESTRIAN BRIDGES IN THE FLOODWAY THAT ARE NOT ABLE TO PASS THE 100 YEAR FLOW ARE
REQUIRED TO BE “BREAKAWAY” AND TETHERED.
9.CURVES AND LINES ARE MEASURED AT FLOWLINE, CENTERLINE OR EDGE OF WALK.
10.ATTACHED WALK WIDTHS ARE FROM FLOWLINES.
11.SINGLE POINT CURB TRANSITIONS ARE 6'.
12.SIGN PLACEMENT SHALL BE PER THE LATEST EDITION OF MUTCD REGARDLESS OF PLAN LOCATION.
13.ALL CURB & GUTTER CALLS ARE UNLESS OTHERWISE NOTED.
PROPOSED VERTICAL CURB & GUTTER
PROPERTY BOUNDARY
EXISTING LOT LINE
PROPOSED LOT LINE
ASPHALT PAVING
PROPOSED OUTFALL VERTICAL CURB & GUTTER
LEGEND:
PRIVATE CONCRETE FLATWORK
SITE SIGN LEGEND
SIGNAGE NOTE:
SIGN LOCATIONS SHOWN ARE
APPROXIMATE. FINAL LOCATION
MAY VARY.
RESERVED
PARKING
2
P
D
C
2
3
4
5
6
7
18" VERTICAL INFLOW CURB & GUTTER
18" FLUSH CURB
30" OUTFALL DRIVE-OVER CURB & GUTTER
18" VERTICAL OUTFALL CURB & GUTTER
PARALLEL ACCESS RAMP
DIRECTIONAL ACCESS RAMP
COMBINATION ACCESS RAMP
8
X' CONCRETE PAN
8
PUBLIC CONCRETE FLATWORK
HEAVY DUTY PRIVATE CONCRETE PAVING
P
FIRE LANE
1' SIDEWALK CHASE
2' SIDEWALK CHASE
X
2' CONCRETE TRICKLE PAN
1
6" CURB CUT
1
P0TS
3
C 402 C 403
C 401C 400
MHX/ / / / / / / /SUDUDUDE
E
E
E
E
E
E E E E
UD
UDUDU
D
U
D
U
D
U
D
U
D
U
D
U
D
U
D
U
DSSSSSSSS
S
S
UDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
MM
MHXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXX7' SIDEWALK4' SIDEWALK10' SIDEWALK6' SIDEWALK
WALLENBERG DR.EXIST
ING
8
'
TRA
IL
TRACT ACANAL IMPORTATION9' SIDEWALK9' SIDEWALK6' SIDEWALK9' SIDEWALK
6' SIDEWALK
4' SIDEWALK7' SIDEWALK4' SIDEWALK4' SIDEWALKR15'
R15'R25'R3'
R3'
R3'
R25'
R3'
R15'
R25'
R25'
BLDG 8
BLDG 18 BLDG 17
BLDG 16
BLDG 15
BLDG 14
BLDG 13
BLDG 12
BLDG 11
BLDG 10
BLDG 9
N:1449428.90
E:3113756.24
N:1449355.66
E:3113829.81
N:1449423.81
E:3113849.38
N:1449355.65
E:3113785.26
N:1449428.91
E:3113800.80
N:1449350.55
E:3113878.40
N:1449350.56
E:3113922.96
N:1449423.81
E:3113922.95
N:1449294.57
E:3113888.84
N:1449265.55
E:3113962.11
N:1449250.01
E:3113888.85
N:1449220.98
E:3113962.12
N:1449205.55
E:3113891.10
N:1449177.37
E:3113959.68
N:1449163.20
E:3113891.09
N:1449135.02
E:3113959.67
N:1449103.28
E:3113891.06
N:1449075.11
E:3113959.64
N:1449060.94
E:3113891.06
N:1449032.76
E:3113959.63
N:1449040.88
E:3113740.67
N:1449266.93
E:3113799.65
GARAGE 5GARAGE 6
EXISTING SIDEWALK
CULVERT
FEMA 100-YR
HIGH RISK
FLOOD FRINGE
CITY OF FORT
COLLINS 100-YR
FLOODPLAIN
RAIN GARDEN
BIOMEDIA AREA
PROPOSED
LANDSCAPE
WALL (TYP.)
CITY OF FORT COLLINS
100-YR FLOODWAY
PROPOSED 2' PAN
w/ 6" CURBS
EXPOSE BACK
OF CURB
D
D
D
PROPOSED
DRIVE-WAY PER
LCUASS STANDARDS
D
P
D
D
D
D
2
2 2
2
2
2
2
22
2
2
2
2
1
1
3
4
5
6
6
5
6
5
5
5
5
5
7
8
4 4
4
4
4
6
44
6
6
4
4
PROPOSED
LANDSCAPE
WALL
P
1
1
2
1
EXISTING HOBBIT STREET ASPHALT
TO BE MILLED & OVERLAYED
PER CITY STANDARDS
SIDEWALK WITH
THICKENED EDGE
PROPOSED
LANDSCAPE
WALL
PROPOSED 2' PAN
w/ 6" CURBS
3
3
3
11' SIDEWALK
TRENCH DRAIN
PROPOSED
MONUMENT SIGN
9'
9'
8.5'
8.5'
8.5'17'
8.5'
17'
17'
8.5'
17'
8.5'
17'
17'
17'
8.5'
8.5'
8.5'
8.5'
8.5'
17'
17'
26'
FL-FL
26'
FL-FL 26' EMERGENCYACCESS EASEMENT26' EMERGENCY
ACCESS
EASEMENT
26'
FL-FL
8'15'
8'17'
8.5'
21'26' EMERGENCYACCESSEASEMENT24' ACCESS
EASEMENT
1
5' SIDEWALK
12" CURB
7' CURB
TRANSITION7' CURB
TRANSITION
DASHLAR DRR25'
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
( IN FEET )
0
1 INCH = 30 FEET
30 30 60 90
NORTH
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
RSEE SHEET C 400C 401PAVING PLAN7SEE SHEET C 403
EASEMENTS
NOTES:
1.SEE DETAIL SHEETS FOR ADDITIONAL INFORMATION REGARDING CURBS AND PAVEMENT SECTIONS.
2.PAVEMENT MARKINGS SHALL BE PER CITY OF FORT COLLINS STANDARDS AND PROJECT SPECIFICATION
MANUAL.
3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE
CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF
FORT COLLINS STREET REPAIR STANDARDS.
4.ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS,
SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS
PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE
DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO
THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY.
5.ALL PUBLIC CONCRETE PAVING SHALL BE 6" THICK.
6.REFER TO SITE AND LANDSCAPE PLANS (BY OTHERS) FOR ADDITIONAL INFORMATION RELATED TO
DECORATIVE PAVING, HARDSCAPES, AND OTHER SITE AMENITIES.
7.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE CITYREGULATED, 100YEAR CANAL IMPORTATION
FLOODPLAIN/FLOODWAY AS WELL AS THE FEMA REGULATED SPRING CREEK 100YEAR
FLOODPLAIN/FLOODWAY. ANY DEVELOPMENT WITHIN THE FLOODPLAIN MUST COMPLY WITH THE SAFETY
REGULATIONS OF CHAPTER 10 OF CITY MUNICIPAL CODE. THE DEVELOPER SHALL OBTAIN A FLOODPLAIN
USE PERMIT FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE PERMIT FEES
PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES, GRADING, FILL,
DETENTION PONDS, BIKE PATHS, PARKING LOTS, UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL
CHANNELS, ETC.) WITHIN THE CITY OF FORT COLLINS FLOODPLAIN LIMITS AS DELINEATED ON THE FINAL
SUBDIVISION PLAT
8.ANY CONSTRUCTION ACTIVITIES, NONSTRUCTURAL DEVELOPMENT (BRIDGES, SIDEWALKS, CULVERTS,
VEGETATION, CURBCUTS, GRADING, ETC.) IN THE REGULATORY FLOODWAY MUST BE PRECEDED BY A
NORISE CERTIFICATION, WHICH MUST BE PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN THE
STATE OF COLORADO.
9.NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE FLOODWAY, WHETHER
TEMPORARY (DURING CONSTRUCTION) OR PERMANENT.
8.ANY PEDESTRIAN BRIDGES IN THE FLOODWAY THAT ARE NOT ABLE TO PASS THE 100 YEAR FLOW ARE
REQUIRED TO BE “BREAKAWAY” AND TETHERED.
9.CURVES AND LINES ARE MEASURED AT FLOWLINE, CENTERLINE OR EDGE OF WALK.
10.ATTACHED WALK WIDTHS ARE FROM FLOWLINES.
11.SINGLE POINT CURB TRANSITIONS ARE 6'.
12.SIGN PLACEMENT SHALL BE PER THE LATEST EDITION OF MUTCD REGARDLESS OF PLAN LOCATION.
13.ALL CURB & GUTTER CALLS ARE UNLESS OTHERWISE NOTED.
PROPOSED VERTICAL CURB & GUTTER
PROPERTY BOUNDARY
EXISTING LOT LINE
PROPOSED LOT LINE
ASPHALT PAVING
PROPOSED OUTFALL VERTICAL CURB & GUTTER
LEGEND:
PRIVATE CONCRETE FLATWORK
SITE SIGN LEGEND
SIGNAGE NOTE:
SIGN LOCATIONS SHOWN ARE
APPROXIMATE. FINAL LOCATION
MAY VARY.
RESERVED
PARKING
2
P
D
C
2
3
4
5
6
7
18" VERTICAL INFLOW CURB & GUTTER
18" FLUSH CURB
30" OUTFALL DRIVE-OVER CURB & GUTTER
18" VERTICAL OUTFALL CURB & GUTTER
PARALLEL ACCESS RAMP
DIRECTIONAL ACCESS RAMP
COMBINATION ACCESS RAMP
8
X' CONCRETE PAN
8
PUBLIC CONCRETE FLATWORK
HEAVY DUTY PRIVATE CONCRETE PAVING
P
FIRE LANE
1' SIDEWALK CHASE
2' SIDEWALK CHASE
X
2' CONCRETE TRICKLE PAN
1
6" CURB CUT
1
P0TS
3
C 402 C 403
C 401C 400
CABLE
F.O.
T FOFOF.O./ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /HILL POND CONDOMINIUMS
UP
6' SIDEWALK
9' SIDEWALK
6' SID
E
W
A
L
K
10' SI
D
E
W
A
L
K
10' SIDEWALK
SPRIN
G
C
R
E
E
K
EXIS
TI
N
G
S
P
RI
N
G
C
R
E
E
K
T
R
AI
L
TRACT C
9' SIDEWALK
9'
9'
9'21'
9'EXISTING ±10' LANEEXISTING ±6' BIKE LANE w/ BUFFEREXISTING ±10' LANEPROPOSED ±9' TURN LANEEXISTING ±10' LANEEXISTING ±10' LANEEXISTING ±10' LANEEXISTING ±10' TURN LANEEXISTING ±10' LANEEXISTING ±6' BIKE LANE w/ BUFFEREXISTING ±10' LANEEXISTING ±6' BIKE LANE w/ BUFFEREXISTING ±6' BIKE LANE w/ BUFFEREXISTING ±10' LANER25'
R25'R75'
R3'
MATCH EXISTING
CURB RETURN
R25'
MATCH EXISTING
CURB RETURN
R25'
R3'
R15'
R75'
R3'
BLDG 1EXISTING SIDEWALKEXISTING SIDEWALKEXISTING SIDEWALKN:1448856.83
E:3113142.11
N:1448927.96
E:3113410.66
N:1448979.06
E:3113213.44
TRACT B
PROPOSED 4'
SIDEWALK CULVERTNATURAL AREA
BUFFER
EXISTING RAMPS TO BE
UPDATED TO CURRENT
CITY STANDARDS
EXISTING RAMPS TO BE
UPDATED TO CURRENT
CITY STANDARDS
PROPOSED
STRIPING (TYP.)
EXISTING
STRIPING (TYP.)
INTERSECTION
STRIPING DETAILS
SEE SHEET INT1
PROPOSED MAINTENANCE
ACCESS PATH
D
D
C
D
D
D
D
D
D
PROPOSED STRIPING
D
2
2 2
2
2
1
1
1
1
1 1
4 4
2
4
4
4
2
66
56
6
7
7
7
4 4 4
4
PARKING
STOP (TYP.)
PARKING
STOP (TYP.)
PARKING
STOP (TYP.)
1
2
PROPOSED
LANDSCAPE
WALL
7 2
3
2
5
D
9'
9'8'
9'
9'
8'
9'
17'
17'17'
17'17'
17'
8.5'
17'
31'
FL-FL
26'
FL-FL
26'
FL-FL
60'
FL-FL
31' EMERGENCY
ACCESS
EASEMENT
21'
33' WATER
EASEMENT
21'
8'
21'
50' PUBLIC ACCESS &
TRAIL EASEMENT
26' EMERGENCY
ACCESS
EASEMENT
9'
21'
9'
5
5
TRENCH
DRAIN
W STUART ST
W STU
A
R
T
S
T
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
NORTH
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
( IN FEET )
0
1 INCH = 30 FEET
30 30 60 90
C 402PAVING PLAN8
EASEMENTS
NOTES:
1.SEE DETAIL SHEETS FOR ADDITIONAL INFORMATION REGARDING CURBS AND PAVEMENT SECTIONS.
2.PAVEMENT MARKINGS SHALL BE PER CITY OF FORT COLLINS STANDARDS AND PROJECT SPECIFICATION
MANUAL.
3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE
CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF
FORT COLLINS STREET REPAIR STANDARDS.
4.ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS,
SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS
PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE
DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO
THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY.
5.ALL PUBLIC CONCRETE PAVING SHALL BE 6" THICK.
6.REFER TO SITE AND LANDSCAPE PLANS (BY OTHERS) FOR ADDITIONAL INFORMATION RELATED TO
DECORATIVE PAVING, HARDSCAPES, AND OTHER SITE AMENITIES.
7.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE CITYREGULATED, 100YEAR CANAL IMPORTATION
FLOODPLAIN/FLOODWAY AS WELL AS THE FEMA REGULATED SPRING CREEK 100YEAR
FLOODPLAIN/FLOODWAY. ANY DEVELOPMENT WITHIN THE FLOODPLAIN MUST COMPLY WITH THE SAFETY
REGULATIONS OF CHAPTER 10 OF CITY MUNICIPAL CODE. THE DEVELOPER SHALL OBTAIN A FLOODPLAIN
USE PERMIT FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE PERMIT FEES
PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES, GRADING, FILL,
DETENTION PONDS, BIKE PATHS, PARKING LOTS, UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL
CHANNELS, ETC.) WITHIN THE CITY OF FORT COLLINS FLOODPLAIN LIMITS AS DELINEATED ON THE FINAL
SUBDIVISION PLAT
8.ANY CONSTRUCTION ACTIVITIES, NONSTRUCTURAL DEVELOPMENT (BRIDGES, SIDEWALKS, CULVERTS,
VEGETATION, CURBCUTS, GRADING, ETC.) IN THE REGULATORY FLOODWAY MUST BE PRECEDED BY A
NORISE CERTIFICATION, WHICH MUST BE PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN THE
STATE OF COLORADO.
9.NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE FLOODWAY, WHETHER
TEMPORARY (DURING CONSTRUCTION) OR PERMANENT.
8.ANY PEDESTRIAN BRIDGES IN THE FLOODWAY THAT ARE NOT ABLE TO PASS THE 100 YEAR FLOW ARE
REQUIRED TO BE “BREAKAWAY” AND TETHERED.
9.CURVES AND LINES ARE MEASURED AT FLOWLINE, CENTERLINE OR EDGE OF WALK.
10.ATTACHED WALK WIDTHS ARE FROM FLOWLINES.
11.SINGLE POINT CURB TRANSITIONS ARE 6'.
12.SIGN PLACEMENT SHALL BE PER THE LATEST EDITION OF MUTCD REGARDLESS OF PLAN LOCATION.
13.ALL CURB & GUTTER CALLS ARE UNLESS OTHERWISE NOTED.
PROPOSED VERTICAL CURB & GUTTER
PROPERTY BOUNDARY
EXISTING LOT LINE
PROPOSED LOT LINE
ASPHALT PAVING
PROPOSED OUTFALL VERTICAL CURB & GUTTER
LEGEND:
PRIVATE CONCRETE FLATWORK
SITE SIGN LEGEND
SIGNAGE NOTE:
SIGN LOCATIONS SHOWN ARE
APPROXIMATE. FINAL LOCATION
MAY VARY.
RESERVED
PARKING
2
P
D
C
2
3
4
5
6
7
18" VERTICAL INFLOW CURB & GUTTER
18" FLUSH CURB
30" OUTFALL DRIVE-OVER CURB & GUTTER
18" VERTICAL OUTFALL CURB & GUTTER
PARALLEL ACCESS RAMP
DIRECTIONAL ACCESS RAMP
COMBINATION ACCESS RAMP
8
X' CONCRETE PAN
8
PUBLIC CONCRETE FLATWORK
HEAVY DUTY PRIVATE CONCRETE PAVING
P
FIRE LANE
1' SIDEWALK CHASE
2' SIDEWALK CHASE
X
2' CONCRETE TRICKLE PAN
1
6" CURB CUT
1
P0TS
3
C 402 C 403
C 401C 400
SEE SHEET C 400
SEE SHEET C 403
XUDUDUDUDUDUDUDUDUDUDUDXXXXXXXXXXXXXXXXWINNE GRANT R/JOHNELLE S
1821 WALLENBERG DR
ERIKSEN CHRISTOPHER M
1825 WALLENBERG DR
MCCOY JOHN H/SHERRY P
1900 S SHIELDS STBBBBBBBBBBBBBBB BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB10' SI
D
E
W
A
L
K
10' SIDEWALK
TRACT B
R25'
R3'
R15'
R25'R25'
R25'
R25'
R75'
SPRING CREEK
EXISTI
N
G
S
P
R
I
N
G
C
R
E
E
K
T
R
A
I
L
GARAGE 6
FEMA 100-YR HIGH
RISK FLOOD FRINGE
PROPOSED LANDSCAPE
WALL (RE: LANDSCAPE)
FEMA 100-YR
FLOODWAY
NATURAL AREA
BUFFER
PROPOSED MAINTENANCE
ACCESS PATH
D
D
D
D
D
D
C
PROPOSED
OVERFLOW
WEIR
2
2
2 2
2
2
1
1
1
4
7
8
6
44
6
6
4
P
1
2
2
3
3
3
2
11' SIDEWALK
8'
8.5'
8.5'
8.5'17'
8.5'
17'
17'
26'
FL-FL
8'15'
8'17'
50' PUBLIC ACCESS &
TRAIL EASEMENT
12' ACCESS
EASEMENT
24' ACCESS
EASEMENT
1
12" CURB
7' CURB
TRANSITION7' CURB
TRANSITION
D
COVERED
BIKE PARKING
W STU
A
R
T
S
T
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
NORTH
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
( IN FEET )
0
1 INCH = 30 FEET
30 30 60 90
C 403PAVING PLAN9
EASEMENTS
NOTES:
1.SEE DETAIL SHEETS FOR ADDITIONAL INFORMATION REGARDING CURBS AND PAVEMENT SECTIONS.
2.PAVEMENT MARKINGS SHALL BE PER CITY OF FORT COLLINS STANDARDS AND PROJECT SPECIFICATION
MANUAL.
3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE
CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF
FORT COLLINS STREET REPAIR STANDARDS.
4.ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS,
SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS
PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE
DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO
THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY.
5.ALL PUBLIC CONCRETE PAVING SHALL BE 6" THICK.
6.REFER TO SITE AND LANDSCAPE PLANS (BY OTHERS) FOR ADDITIONAL INFORMATION RELATED TO
DECORATIVE PAVING, HARDSCAPES, AND OTHER SITE AMENITIES.
7.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE CITYREGULATED, 100YEAR CANAL IMPORTATION
FLOODPLAIN/FLOODWAY AS WELL AS THE FEMA REGULATED SPRING CREEK 100YEAR
FLOODPLAIN/FLOODWAY. ANY DEVELOPMENT WITHIN THE FLOODPLAIN MUST COMPLY WITH THE SAFETY
REGULATIONS OF CHAPTER 10 OF CITY MUNICIPAL CODE. THE DEVELOPER SHALL OBTAIN A FLOODPLAIN
USE PERMIT FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE PERMIT FEES
PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES, GRADING, FILL,
DETENTION PONDS, BIKE PATHS, PARKING LOTS, UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL
CHANNELS, ETC.) WITHIN THE CITY OF FORT COLLINS FLOODPLAIN LIMITS AS DELINEATED ON THE FINAL
SUBDIVISION PLAT
8.ANY CONSTRUCTION ACTIVITIES, NONSTRUCTURAL DEVELOPMENT (BRIDGES, SIDEWALKS, CULVERTS,
VEGETATION, CURBCUTS, GRADING, ETC.) IN THE REGULATORY FLOODWAY MUST BE PRECEDED BY A
NORISE CERTIFICATION, WHICH MUST BE PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN THE
STATE OF COLORADO.
9.NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE FLOODWAY, WHETHER
TEMPORARY (DURING CONSTRUCTION) OR PERMANENT.
8.ANY PEDESTRIAN BRIDGES IN THE FLOODWAY THAT ARE NOT ABLE TO PASS THE 100 YEAR FLOW ARE
REQUIRED TO BE “BREAKAWAY” AND TETHERED.
9.CURVES AND LINES ARE MEASURED AT FLOWLINE, CENTERLINE OR EDGE OF WALK.
10.ATTACHED WALK WIDTHS ARE FROM FLOWLINES.
11.SINGLE POINT CURB TRANSITIONS ARE 6'.
12.SIGN PLACEMENT SHALL BE PER THE LATEST EDITION OF MUTCD REGARDLESS OF PLAN LOCATION.
13.ALL CURB & GUTTER CALLS ARE UNLESS OTHERWISE NOTED.
PROPOSED VERTICAL CURB & GUTTER
PROPERTY BOUNDARY
EXISTING LOT LINE
PROPOSED LOT LINE
ASPHALT PAVING
PROPOSED OUTFALL VERTICAL CURB & GUTTER
LEGEND:
PRIVATE CONCRETE FLATWORK
SITE SIGN LEGEND
SIGNAGE NOTE:
SIGN LOCATIONS SHOWN ARE
APPROXIMATE. FINAL LOCATION
MAY VARY.
RESERVED
PARKING
2
P
D
C
2
3
4
5
6
7
18" VERTICAL INFLOW CURB & GUTTER
18" FLUSH CURB
30" OUTFALL DRIVE-OVER CURB & GUTTER
18" VERTICAL OUTFALL CURB & GUTTER
PARALLEL ACCESS RAMP
DIRECTIONAL ACCESS RAMP
COMBINATION ACCESS RAMP
8
X' CONCRETE PAN
8
PUBLIC CONCRETE FLATWORK
HEAVY DUTY PRIVATE CONCRETE PAVING
P
FIRE LANE
1' SIDEWALK CHASE
2' SIDEWALK CHASE
X
2' CONCRETE TRICKLE PAN
1
6" CURB CUT
1
P0TS
3
C 402 C 403
C 401C 400
SEE SHEET C 401
SEE SHEET C 402
MHUDE
E E E
U
D
U
D
U
D
U
DSS
S
S
UDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
MM
MH
/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /XXXXXXXXXXXXXXXXXXXXXXWINNE GRANT R/JOHNELLE S
1821 WALLENBERG DR
ERIKSEN CHRISTOPHER M
1825 WALLENBERG DR
MCCOY JOHN H/SHERRY P
1900 S SHIELDS ST
UP
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBXXXBBBBBBBBBXXXXXXXXX6' SIDEWALK
6' SIDEWALK6' SIDEWALK
6' SIDEWALK
9' SIDEWALK6' SIDEWALK
9' SIDEWALK
6' SID
E
W
A
L
K
10' SID
E
W
A
L
K 7' SIDEWALK4' SIDEWALK
5' SIDEWALK 10' SIDEWALK6' SIDEWALK
HOBBIT ST.WALLENBERG DR.10' SIDEWALK
10' SIDEWALK
6' SIDEWALK
SPRIN
G
C
R
E
E
K
EXIS
TI
N
G
S
P
RI
N
G
C
R
E
E
K
T
R
AI
LEXISTING SIDEWALKLOT 1
TRACT B
TRACT C CANAL IMPORTATION9' SIDEWALK9' SIDEWALK8' SIDEWALK9' SIDEWALK5' SIDEWALK9' SIDEWALK 6' SIDEWALK6' SIDEWALK
9' SIDEWALK
6' SIDEWALK
5' SIDEWALK9' SIDEWALK5' SIDEWALK
4.5' SIDEWALK
4' SIDEWALK7' SIDEWALK4.5' SIDEWALK
4' SIDEWALK4' SIDEWALKBLDG 6 BLDG 7
BLDG 2
BLDG 3
BLDG 4 BLDG 5 BLDG 8
BLDG 18
BLDG 17
BLDG 16
BLDG 15
BLDG 14
BLDG 13
BLDG 12
BLDG 11
BLDG 10
BLDG 9
BLDG 1
N:1448856.83
E:3113142.11
N:1448927.96
E:3113410.66
N:1448979.06
E:3113213.44
N:1449042.86
E:3113153.80
N:1449260.66
E:3113202.71
N:1449362.97
E:3113148.87
N:1449415.10
E:3113338.48
N:1449419.74
E:3113376.26
N:1449360.75
E:3113602.30
N:1449428.90
E:3113756.24
N:1449355.66
E:3113829.81
N:1449423.81
E:3113849.38
N:1449355.65
E:3113785.26
N:1449428.91
E:3113800.80
N:1449350.55
E:3113878.40
N:1449350.56
E:3113922.96
N:1449423.81
E:3113922.95
N:1449294.57
E:3113888.84
N:1449265.55
E:3113962.11
N:1449250.01
E:3113888.85
N:1449220.98
E:3113962.12
N:1449205.55
E:3113891.10
N:1449177.37
E:3113959.68
N:1449163.20
E:3113891.09
N:1449135.02
E:3113959.67
N:1449103.28
E:3113891.06
N:1449075.11
E:3113959.64
N:1449060.94
E:3113891.06
N:1449032.76
E:3113959.63
N:1449040.88
E:3113740.67
N:1449266.93
E:3113799.65
N:1449210.25
E:3113641.62
N:1449020.70
E:3113589.30
N:1449020.72
E:3113543.88
N:1449210.33
E:3113491.75
N:1449030.63
E:3113288.75
N:1449079.34
E:3113452.93
SPRING CREEK
EXISTI
N
G
S
P
R
I
N
G
C
R
E
E
K
T
R
A
I
L
GARAGE 1
GARAGE 2
GARAGE 3 GARAGE 4
GARAGE 5GARAGE 6
11' SIDEWALK
26' EMERGENCY
ACCESS
EASEMENT
FEMA 100-YR HIGH
RISK FLOOD FRINGE
NATURAL AREA
BUFFER
EXISTING RAMP TO BE
UPDATED TO CURRENT
CITY STANDARDS
EXISTING RAMPS
CITY STANDARDS
EXISTING RAMPS
TO BE UPDATED
TO CURRENT
CITY STANDARDS
FEMA 100-YR
FLOODWAY
NATURAL AREA
BUFFER
PROPOSED MAINTENANCE
ACCESS PATH
P P
PROPOSED
DRIVE-WAY
PER
LCUASS
STANDARDS
P
P
TRASH
ENCLOSURE
P
P
P
P P
P
P
E
E
E
E
E
E E E E E E
E
E
E
G
G
FFE=16.50 FFE=16.67
FFE=19.00
FFE=19.65 FFE=17.50
FFE=15.65
FFE=15.00
FFE=15.00
FFE=14.83
FFE=14.83
FFE=15.00
FFE=15.00
FFE=15.43
FFE=15.43
FFE=15.82
FFE=15.82
FFE=17.27
FFE=17.49 ASHLAR DRW STUART ST
G
MAINTENANCE
GARAGE
E E
E
E
E
E
E
E
E
E
EE
E
E
E
E
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
C 410ADA ROUTING PLAN10
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
NORTH
( IN FEET )
1 inch = ft.
Feet04040
40
80 120
EASEMENTS
NOTES:
1.SEE DETAIL SHEETS FOR ADDITIONAL INFORMATION REGARDING CURBS AND PAVEMENT SECTIONS.
2.PAVEMENT MARKINGS SHALL BE PER CITY OF FORT COLLINS STANDARDS AND PROJECT SPECIFICATION
MANUAL.
3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE
CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF
FORT COLLINS STREET REPAIR STANDARDS.
4.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE CITYREGULATED, 100YEAR CANAL IMPORTATION
FLOODPLAIN/FLOODWAY AS WELL AS THE FEMA REGULATED SPRING CREEK 100YEAR
FLOODPLAIN/FLOODWAY. ANY DEVELOPMENT WITHIN THE FLOODPLAIN MUST COMPLY WITH THE SAFETY
REGULATIONS OF CHAPTER 10 OF CITY MUNICIPAL CODE. THE DEVELOPER SHALL OBTAIN A FLOODPLAIN
USE PERMIT FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE PERMIT FEES
PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES, GRADING, FILL,
DETENTION PONDS, BIKE PATHS, PARKING LOTS, UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL
CHANNELS, ETC.) WITHIN THE CITY OF FORT COLLINS FLOODPLAIN LIMITS AS DELINEATED ON THE FINAL
SUBDIVISION PLAT
5.SIGN PLACEMENT SHALL BE PER THE LATEST EDITION OF MUTCD REGARDLESS OF PLAN LOCATION.
PROPOSED VERTICAL CURB & GUTTER
PROPERTY BOUNDARY
EXISTING LOT LINE
PROPOSED LOT LINE
PROPOSED OUTFALL VERTICAL CURB & GUTTER
LEGEND:
ADA ACCESSIBILITY PATH
E
P
G
ADA ACCESSIBLE BUILDING ENTRANCE
ADA ACCESSIBLE PARKING
ADA ACCESSIBLE GARAGE
TTTTTTTTT/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /EEEEEEEEEE E E
FDC
FDCFDC
G
G G
G
EXISTING STRIPING (TYP.)
14' RIGHT TURN LANE
7' BIKE LANE
3' BIKE LANE BUFFER
11' LEFT/THRU LANE
11' EASTBOUND THRU LANE
3' BIKE LANE BUFFER
7' BIKE LANE
WEST STUART STREET SHIELDS STREET100'' STORAGE LENGTH180'' BAY TAPEREXISTING 7' SIDEWALKFUTURE PEDESTRIAN
RAMP (FOR
REFERENCE ONLY)
FUTURE PEDESTRIAN
RAMPS (FOR
REFERENCE ONLY)
9' SIDEWALK
10' SIDEWALK
EXISTING ±6' BIKE LANE
EXISTING ±12'RIGHT TURN LANE
±10' LEFT/THRU LANE
EXISTING ±12' THRU LANE
EXISTING ±8' PARKING
EXISTING ±3' BIKE LANE BUFFER
EXISTING ±7' BIKE LANE
EXISTING ±7' BIKE LANEEXISTING ±3' BIKE LANE BUFFEREXISTING ±10' THRU LANEEXISTING ±10' THRU LANEEXISTING ±9' BIKE LANEEXISTING ±10' TURN LANEEXISTING ±10' THRU LANEEXISTING ±10' THRU LANEEXISTING ±7' BIKE LANEEXISTING ±3' BIKE LANE BUFFEREXISTING ±10' THRU LANEEXISTING ±10' THRU LANEEXISTING ±7' BIKE LANEPROPOSED ±9.5' TURN LANEEXISTING ±10' THRU LANEEXISTING ±10' THRU LANEEXISTING ±3' BIKE LANE BUFFERPROPOSED
STRIPING
EXISTING
STRIPING (TYP.)
PROPOSED
PAVEMENT MARKINGS
EXISTING VERTICAL
CURB & GUTTER (TYP.)EXISTING ±7' SIDEWALKEXISTING ±7' SIDEWALKEXISTING ±8' SIDEWALKPROPOSED VERTICAL
CURB & GUTTER
PROPOSED
STRIPING
PROPOSED
PAVEMENT MARKINGS
APPROXIMATE EXISTING
STRIPING (TYP.)
PROPOSED RESTRIPING OF
EXISTING LEFT TURN LANE
4'x4' ADA
LANDING
PEDESTRIAN
PUSH BUTTON
9.96'
9.09'
4'x4' ADA
LANDING
PEDESTRIAN
PUSH BUTTON
8.56'
8.89'4'x4' ADA
LANDING
(BY OTHERS)
4'x4' ADA
LANDING
(BY OTHERS)
8.27'
PEDESTRIAN
PUSH BUTTON
(BY OTHERS)
PEDESTRIAN
PUSH BUTTON
(BY OTHERS)
FUTURE PEDESTRIAN
RAMP (FOR
REFERENCE ONLY)
8.07'
9.41'
W STUART ST
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
C 410INTERSECTION STRIPING PLAN11
NORTH
( IN FEET )
1 inch = ft.
Feet02020
20
40 60
EXISTING RIGHT-OF-WAY
LEGEND:
PROPOSED STORM SEWER
EXISTING STORM SEWER
PROPOSED EDGE OF ASPHALT
PROPOSED STORM MANHOLE
/ / / / / / / /
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PEDESTRIAN ACCESS RAMPS
PROPOSED CONCRETE
CROSSPAN (TYP.)
PROPOSED RIGHT-OF-WAY
NOTES:
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND
RECOMMENDATIONS.
3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN
THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS
TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS.
4.SEE INTERSECTION DETAIL SHEETS FOR INTERSECTION DESIGNS.
5.EXISTING AND PROPOSED MANHOLE RIMS AND VALVE BOX LIDS TO BE ADJUSTED TO
1
4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO
PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
PROPERTY BOUNDARY
PROPOSED LOT LINE
EASEMENT LINE
SAWCUT LINE
EXISTING LOT LINE
PROPOSED STORM INLET
C 420
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
T
MH
U
D
S
S
UDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDD
D
MH
MM
MH
/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /XXXXXXXXXXXXXXXXXSTSTSTSTSTSTSTSTWINNE GRANT R/JOHNELLE S
1821 WALLENBERG DR
ERIKSEN CHRISTOPHER M
1825 WALLENBERG DR
MCCOY JOHN H/SHERRY P
1900 S SHIELDS ST
HILL POND CONDOMINIUMS BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBXXXBBBBBBBBBXXXXXXXEEEEE
EEE
EEEEEEEEEEEEE
UDUDUDUD
UDEEEEEE
EE EEE E
FDC
FDCFDC FDC
FDCFDCFDCFDC ENYLOPLAST
DO NOT POLLUTE DRAINS TO WATERWAYS
NYLOPLAST
DO NOT POLLUTE DRAINS TO WATERWAYS
EE
E EEEEE E E E E EEEE E EEEEEE
NYLOPLAST
DO NOT POLLUTE DRAINS TO WATERWAYSS SHIELDS ST.HOBBIT ST.WALLENBERG DR.FEMA 100-YR
HIGH RISK
FLOOD FRINGE
CITY OF FORT COLLINS
100-YR FLOODPLAIN
PROPOSED 4'
CONCRETE PAN
PROPOSED 4'
CONCRETE PAN
PROPOSED 4'
CONCRETE PAN
PROPOSED 4'
CONCRETE PAN
PROPOSED 4'
CONCRETE PAN
PROPOSED 4'
CONCRETE PAN
PROPOSED 6'
CONCRETE PAN
PROPOSED 4'
CONCRETE PAN
PROPOSED 4'
CONCRETE PAN
PROPOSED 4'
CONCRETE PAN
PROPOSED 4'
CONCRETE PAN
EXIST
I
N
G
S
P
R
I
N
G
C
R
E
E
K
T
R
A
I
L
PROPOSED 2'
CONCRETE PAN
PROPOSED 2'
CONCRETE PAN
PROPOSED
RAIN GARDEN
PROPOSED OUTLET
STRUCTURE
PROPOSED DRAINAGE
EASEMENT
LOT 1
TRACT B
TRACT A
TRACT C
SPRI
N
G
C
R
E
E
K
RAIN GARDEN
BIOMEDIA AREA
PROPOSED 2'
CONCRETE PAN
PROPOSED 4'
SIDEWALK
CULVERTEXISTING SIDEWALKEXISTING 8' TRAILPROPOSED
LANDSCAPE WALL
CANAL IMPORTATIONPROPOSED 2'
CONCRETE PAN
STORM DRAIN 1
SEE SHEET C 620
FEMA 100-YR
FLOODWAY
CITY OF FORT
COLLINS 100-YR
FLOODWAY
W STUART ST.
STORM DRAIN 1
SEE SHEET C 620
STORM DRAIN 4-4
SEE SHEET C 624
STORM DRAIN 4-4A
SEE SHEET C 624
STORM DRAIN 4
SEE SHEET C 624
STORM DRAIN 1-9
SEE SHEET C 622
STORM DRAIN 1-8
SEE SHEET C 622
STORM DRAIN 5
SEE SHEET C 625
STORM DRAIN 5
SEE SHEET C 625
STORM DRAIN 5-2
SEE SHEET C 625
STORM DRAIN 1
SEE SHEET C 620
STORM DRAIN 2
SEE SHEET C 623
STORM DRAIN 3
SEE SHEET C 623
STORM DRAIN 6
SEE SHEET C 626
UNDERDRAIN
SEE SHEET C 626
POND
OVERFLOW PATH
POND
OVERFLOW PATH
PROPOSED
STORM CHAMBERS
PROPOSED
STORM CHAMBERS
STORM DRAIN 1-5
SEE SHEET C 621
STORM DRAIN 1-6
SEE SHEET C 621
BLDG 6 BLDG 7
BLDG 2
BLDG 3
BLDG 4
BLDG 5
BLDG 8BLDG 18BLDG 17BLDG 16BLDG 15BLDG 14
BLDG 13
BLDG 12
BLDG 11
BLDG 10
BLDG 9
BLDG 1
EMERGENCY
OVERFLOW WEIR
PROPOSED
LANDSCAPE WALL
CULVERTS
SEE SHEET U1-U4
CULVERT
SEE SHEET U1-U4
CULVERTS
SEE SHEET U1-U4
CULVERT
SEE SHEET U1-U4
AREA DRAINS
SEE SHEET U1-U4
PROPOSED OUTLET
STRUCTURE
AREA DRAINS
SEE SHEET U1-U4
FFE=19.00
FFE=17.49
FFE=16.50
FFE=16.67
FFE=15.65
FFE=17.27
FFE=14.83
FFE=14.83
FFE=15.00
FFE=15.00
FFE=15.00
FFE=15.00FFE=15.43FFE=15.43FFE=15.82FFE=15.82FFE=17.50FFE=19.65
ASHLAR DRW STU
A
R
T
S
T
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
C 500OVERALL GRADING PLAN12
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
NORTH
( IN FEET )
1 inch = ft.
Feet05050
50
100 150
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
PROPOSED SLOPES
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL
UNKNOWN UNDERGROUND UTILITIES.
2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD 88. SEE COVER SHEET FOR
BENCHMARK REFERENCES.
4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE
FINISHED GRADE ELEVATIONS.
5.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE CITY REGULATED 100-YR
CANAL IMPORTATION FLOODPLAIN/FLOODWAY AS WELL AS THE FEMA REGULATED
SPRING CREEK 100-YR FLOODPLAIN/FLOODWAY. ANY DEVELOPMENT WITHIN THE
FLOODPLAIN MUST COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF
CITY MUNICIPAL CODE. THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT
FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE
PERMIT FEES PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF
STRUCTURES, GRADING, FILL, DETENTION PONDS, BIKE PATHS, PARKING LOTS,
UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE
CITY OF FORT COLLINS FLOODPLAIN LIMITS AS DELINEATED ON THE FINAL
SUBDIVISION PLAT.
6.ANY CONSTRUCTION ACTIVITIES, NONSTRUCTURAL DEVELOPMENT (BRIDGES,
SIDEWALKS, CULVERTS, VEGETATION, CURB CUTS, GRADING, ETC.) IN THE
REGULATORY FLOODWAY MUST BE PRECEDED BY A NO RISE CERTIFICATION,
WHICH MUST BE PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN THE
STATE OF COLORADO.
7.NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE
FLOODWAY, WHETHER TEMPORARY (DURING CONSTRUCTION) OR PERMANENT.
8.ANY PEDESTRIAN BRIDGES IN THE FLOODWAY THAT ARE NOT ABLE TO PASS THE
100-YR FLOW ARE REQUIRED TO BE "BREAKAWAY" AND TETHERED.
NOTES:
PROPOSED STORM INLET
2.0%
(47.45
)
EXISTING SPOT ELEVATION
EXISTING LOT LINE
PROPOSED CONCRETE
CROSS PAN (TYP.)
33.43
EXISTING RIGHT OF WAY
PROPOSED LOT LINE
PROPOSED RIGHT OF WAY
LEGEND:
PROPOSED GRADE BREAK
C 501 C 502
C 503 C 504
C 506 C 505C 505
/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /6' SIDEWALK
5' SIDEWALK
6' SIDEWALK
6' SIDEWALK6' SIDEWALK
6' SIDEWALK
4.5' SIDEWALK
S SHIELDS ST.HOBBIT ST.
4.5' SIDEWALK
5' SIDEWALKFDC
FDCFDC
FDC17.761
7
.
8
4
17.83
1
7
.
3
9
17.2917.5417.4517.3217.0216.9118.641
7
.
9
0
18.34
18.3416.67
16.
5
2
16.0816.
2
0
16.82 15.2816.49
16.0516.07 15.8217.0717.55
1
6
.
5
117.7715.17
17.
0
5
19.00 18.341
8
.
9
9
19.
5
8
19.65
19.65
19.
6
5
2.3%2.8%4.2%3.9%3.0%2.0%2.3%1.2%
2.1%
1.9%2.4%2.4%2.4%0.5%0.2%2.0%1.5%2.0%
0.5%0.5%
LOT 1EXISTING SIDEWALK9' SIDEWALKLOT 1
LOT 1
1.3%1.7%2.0%0.5%0.5%1.5%17.811
7
.
8
1
17.881.6%0.5%9' SIDEWALK1.6%0.5%29' HALF ROW
FFE=16.50
FFE=19.00
FFE=19.65 FFE=17.50
FFE=17.49
PROPOSED 4'
CONCRETE PAN PROPOSED 4'
CONCRETE PAN
PROPOSED 4'
CONCRETE PAN
PROPOSED 4'
CONCRETE PAN
PROPOSED 2'
CONCRETE PAN
PROPOSED 2'
CONCRETE PAN
PROPOSED
AREA DRAIN
26' EMERGENCY ACCESS EASEMENT
26' EMERGENCY ACCESS EASEMENT
26' EMERGENCY ACCESS EASEMENT
26' EMERGENCY ACCESS EASEMENT
26' EMERGENCY ACCESS EASEMENT
48' SANITARY SEWER EASEMENT
PROPOSED 30" VERTICAL
CURB & GUTTER
PROPOSED
LANDSCAPE WALL PROPOSED
AREA DRAIN
PROPOSED
AREA DRAIN
STORM DRAIN 1
SEE SHEET C 620
STORM DRAIN 1-9
SEE SHEET C 622
17.
2
7
16.3516.
7
3
16.85 1.5%2.0%PROPOSED
AREA DRAIN
PROPOSED
AREA DRAIN2.8%BUILDING 6
BUILDING 7
BUILDING 2
BUILDING 3
BUILDING 416.0216.6615.
6
2 15.5816.24 16.37
15.
1
7
15.5316.0415.9116.4816.42 15.4115.
9
00.5%0.5%16.4116.
0
8
2.0%
2.0%
1.7%0.5%0.7%17.8415.
2
6
15.4115.5615.
7
3
15.
9
4 15.96
15.
4
2
15.05
14.88
15.96
1
6
.
0
3
16.1717.0717.09
17.
1
8
17.05
16.52
16.54
16.61
16.49
16.40
16.1815.80
15.3015.
1
1
15.7015.6115.6315.70
16.23
16.
0
9
16.
1
9
16.2217.0417.0017.0417.1717.
1
0
16.9316.8416.8216.61
16.
5
4
1
6
.
1
6
16.29
1
6
.
2
8
15.5315.45
17.7817.7217.700.7%17.2017.14
17.43
HP
17.28
1
7
.
2
3
16.
8
2
16.8216.90
17.
1
3
15.
1
817.0616.920.5%15.1715.0215.78
15.
6
8
15.70
16.3016.20
16.17
16.19
16.2817.76
17.6017.61
17.80
18.
3
2 15.70LP16.17
LP
0.5%
2.0%15.100.5%PROPOSED 2'
SIDEWALK
CHASES
PROPOSED 1'
SIDEWALK CHASE
PROPOSED 1'
SIDEWALK
CHASE
PROPOSED 1'
SIDEWALK CHASE
PROPOSED 2'
SIDEWALK CHASE
PROPOSED 2'
SIDEWALK CHASE
PROPOSED 1' SIDEWALK
CHASEPROPOSED 1'
SIDEWALK CHASE
PROPOSED 2'
CURB CUT
PROPOSED 1'
CURB CUT
AREA DRAINS
SEE SHEET C 601-C 60618.46HP18.41
18.
3
7
18.2918.4918.2218.2519.2019.5619.0019.
0
0
19.6518.9918.9218.901
8
.
3
4 18.8618.2518.3418.3318.8119.6519.5619.6518.9918.9918.89
18.9019.6519.
5
0 19.6518.9918.9918.9219.5619.6518.9919.6519.
5
619.4017.
9
0
17.8017.30
16.98
16.
9
3
16.6916.66
17.1717.6017.5418.03
18.3417.4918.0017.6217.4916.6718.7618.6817.9717.
2
1
19.
6
5
19.
6
2 19.4918.3217.6017.
6
3
18.
1
8 18.1017.
3
0 17.2417.0216.9519.76(19.82)19.48
19.6519.5619.39 18.561
8
.
5
9 18.511
8
.
0
0
17.
9
718.1219.111
9
.
1
8
19.
4
619.241
9
.
6
5
19.55
1
9
.
6
2
19.65
19.56 19.5619.5018.2318.2719.4520.2819.4219.56
19.6518.
9
9
1
8
.
9
9
18.991.5%2.0%18.2918.2018.244.5%3.1%2.0%2.0%2.0%2.0%18.16
0.5%18.8918.4320.25MATCH EXISTING
PAVEMENT
PROPOSED
STAIRS
PROPOSED
STAIRS
PROPOSED
STAIRS
PROPOSED 2'
SIDEWALK CHASE
2.0%1.5%1.5%1.7%2.7%1.5%PROPOSED
STAIRS
PROPOSED
STAIRS
PROPOSED
STAIRS
1.6%0.6%1.0%1.8%1.5%0.5%
0.5%
2.0%2.0%1.5%1.4%1.6%1.5%2.0%0.6%0.6%17.5016.8716.8316.7516.751
6
.
7
5
1
6
.
2
8 16.2616.7516.6116.1416.1616.6716.1715.9216.33HP16.2416.25HP15.900.5%17.0715.80HP16.4316.3716.14
HP
16.49
1
7
.
4
1
17.40
17.5016.
8
3
15.18 15.7015.6515.67
17.42 17.4617.50
1
7
.
5
0
17.
3
3
15.5815.4215.3714.87
14.89
14.
5
0
14.4814.9815.0314.99 15.53
15.59
17.34
17.4017.5017.5017.4617.40
15.65
15.59
14.76
14.
2
014.7317.
5
0
17.4017.5016.8316.7516.7517.4016.
8
317.5017.4017.5016.8316.8315.
1
5
17.
4
0
18.87
18.92AREA DRAINS
SEE SHEET C 601-C 606
AREA DRAINS
SEE SHEET C 601-C 606
CULVERTS
SEE SHEET U1-U4
CULVERTS
SEE SHEET C 601-C 606
CULVERTS
SEE SHEET C 601-C 606
CULVERTS
SEE SHEET C 601-C 606
PROPOSED 2'
CONCRETE PAN
PROPOSED 2'
CONCRETE PAN
(19.64)(19.62)(20
.
2
3
)
PROPOSED 2'
PAN w/ 6" CURB
17.27
16.41
16.
3
8
1
6
.
0
1
1
5
.
9
3
1
5
.
4
9 15.231
4
.
9
4
16.20
1
4
.
9
8 14.871
4
.
8
2
LP15.2215.131
7
.
1
017.1016.41
16.92
16.51
17.26
16.
3
0
16.62
16.28
16.96 16.1516.41
15.0915.
0
6
14.97
14.
9
4
LP
15.1315.3016.
0
5
15.24
15.28
1
5
.
6
4
16.
0
916.2016.0717.11
LP
17.96
HP16.82LP1
6
.
0
6 16.031
5
.
6
1
1
5
.
5
9 15.151
8
.
3
4 17.9817.90
17.8118.1218.1617.9017.6217.7317.2017.11
17.1217.03
17.191
6
.
6
719.0018.9118.3418.3418.13
18.1317.4916.5517.7618.18(19.55)(19.54)
(19
.
3
0
)
(19
.
2
9
)
(19
.
2
5
)
(19.24)
(18.90)
(18.86)
(18
.
7
9
)
(18.77)
(18.46)
(18.45)
19.00
18.94
16.
6
9
18.3316.9719.0018.92
18.80
18.35
18.37
18.97
18.91
19.00
18.77
17.14
17.24
18.91
19.00
18.44
18.
3
6 18.91
18.97
19.00
18.8617.4118.34
18.
3
417.6918.95
19.00
18.81
1
8
.
1
7HP
18.3419.
0
0
18.9119.001
8
.
3
4
18.14
17.
6
417.681
7
.
7
7
1
7
.
7
3
18.15
1
8
.
3
3
17.69
19.00
18.91
19.00
18.34
18.10
18.1517.5618.00
17.
9
0
18.34
2.0%
1.5%
1.1%1.5%3.3%2.0%0.6%1
5
.
2
0
15.
5
0
HP
2.0%0.6%0.5%4.5%0.6%0.5%1.7%2.0%1.4%0.8%2.0%1.5%15.83
2.0%1.2%2.0%
16.
4
5
16.37
17.30
17.
1
6
17.16
16.25 16.37
16.8216.7316.7016.7516.29
16.87
16.
3
3
16.1916.2416.3316.32
16.58
HP 16.82
16.
8
2 16.80
16.82
16.8216.82
17.16 15.7315.34
15.
8
9
17.00
16.00
16.06
15.
9
3
15.
0
9
14.
9
7
15.
1
2
15.
8
3
1
5
.
8
3
15.33
15.
3
3
15.
8
4
16.
5
015.2116.
5
0
15.
3
3
15.
8
3
15.
3
3
16.50
15.
5
7 16.5015.
9
3
16.
0
0
1
6
.
5
0
15.8315.81
15.87
15.
9
5
15.24
15.76
16.5016.41
15.91
15.55 15.4615.8515.5415.6315.921
6
.
6
1
1
6
.
5
016.861.6%2.2%2.0%
1.5%
1.5%
PROPOSED 2'
CONCRETE PAN
PROPOSED 2'
CONCRETE PAN
PROPOSED
AREA DRAIN
PROPOSED
AREA DRAIN
PROPOSED
AREA DRAIN
PROPOSED
AREA DRAIN
PROPOSED
AREA DRAIN
PROPOSED
AREA DRAIN
18.75
18.85
CULVERTS
SEE SHEET C 601-C 606
18.07
17.53
1.1%4.2%2.0%
17.43
HP 17.010.5%0.5%0.5%2.0%2.0%1.5%3.7%17.16
17.05
17.16 16.8316.4816.
3
7
3.
0%1.9%3.7%0.8%
PROPOSED 2'
CONCRETE PAN
PROPOSED 2'
CONCRETE PAN
16.
4
0
16.
0
3
15.60
PROPOSED 1'
SIDEWALK CHASE
15.76
15.91
1
6
.
4
1
1
5
.
7
5
15.7815.83
15.
6
9
16.
4
1
1
5
.
8
2
15.8316.131.5%0.5%2.3%1.8%2.2%2.3%1.3%1.0%
15.18
1.5%PROPOSED
AREA DRAIN
PROPOSED
AREA DRAIN
PROPOSED
AREA DRAIN
15.
7
1
PROPOSED
STAIR
16.50
PROPOSED
STAIR
PROPOSED
STAIR
16.50
2.0%1.8%1.8%1.7%1.8%2.0%2.0%2.0%2.9%2.0%0.5%2.6%1.7%2.7%0.6%
17.40
16.1416.161.5%18.22
GARAGE 1
GARAGE 2
GARAGE 3
18.49
HP
15.46HP17.53
PROPOSED 2'
CONCRETE PAN
16.3916.78
17.0817.2115.98HPFFE=
17.30
PROPOSED
AREA DRAIN
PROPOSED 1'
SIDEWALK CHASE18.3%11.2%SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
C 501GRADING PLAN13
( IN FEET )
0
1 INCH = 20 FEET
20 20 40 60
NORTH
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
PROPOSED SLOPES
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL
UNKNOWN UNDERGROUND UTILITIES.
2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD 88. SEE COVER SHEET FOR
BENCHMARK REFERENCES.
4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE
FINISHED GRADE ELEVATIONS.
5.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE CITY REGULATED 100-YR
CANAL IMPORTATION FLOODPLAIN/FLOODWAY AS WELL AS THE FEMA REGULATED
SPRING CREEK 100-YR FLOODPLAIN/FLOODWAY. ANY DEVELOPMENT WITHIN THE
FLOODPLAIN MUST COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF
CITY MUNICIPAL CODE. THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT
FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE
PERMIT FEES PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF
STRUCTURES, GRADING, FILL, DETENTION PONDS, BIKE PATHS, PARKING LOTS,
UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE
CITY OF FORT COLLINS FLOODPLAIN LIMITS AS DELINEATED ON THE FINAL
SUBDIVISION PLAT.
6.ANY CONSTRUCTION ACTIVITIES, NONSTRUCTURAL DEVELOPMENT (BRIDGES,
SIDEWALKS, CULVERTS, VEGETATION, CURB CUTS, GRADING, ETC.) IN THE
REGULATORY FLOODWAY MUST BE PRECEDED BY A NO RISE CERTIFICATION,
WHICH MUST BE PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN THE
STATE OF COLORADO.
7.NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE
FLOODWAY, WHETHER TEMPORARY (DURING CONSTRUCTION) OR PERMANENT.
8.ANY PEDESTRIAN BRIDGES IN THE FLOODWAY THAT ARE NOT ABLE TO PASS THE
100-YR FLOW ARE REQUIRED TO BE "BREAKAWAY" AND TETHERED.
NOTES:
PROPOSED STORM INLET
2.0%
(47.45
)
EXISTING SPOT ELEVATION
EXISTING LOT LINE
PROPOSED CONCRETE
CROSS PAN (TYP.)
33.43
EXISTING RIGHT OF WAY
PROPOSED LOT LINE
PROPOSED RIGHT OF WAY
LEGEND:
PROPOSED GRADE BREAK
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
SEE SHEET C 503 SEE SHEET C 502C 501 C 502
C 503 C 504
C 506 C 505C 505
XUDU
D
U
D
U
D
U
DUDUDUDUD
UD
UD
UD UD UD UD UD UD UD UD UD UD UD UD UD UD
UD S
S
UDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
XXXXXXXXX5' SIDEWALK
6' SIDEWALK
9' SIDEWALK9' SIDEWALK9' SIDEWALK9' SIDEWALK7' SIDEWALK7' SIDEWALK7' SIDEWALK7' SIDEWALK6' SIDEWALKUDUDUDUDUDUDUDFDC
FDCFDCNYLOPLAST
DO NOT POLLUTE DRAINS TO WATERWAYS
NYLOPLAST
DO NOT POLLUTE DRAINS TO WATERWAYS
13.3313.62
13.31
1
3
.
8
9 13.5415.1915.
2
6
14.84
15.
8
3
15.
0
6
15.43
15.4013.97
14.1914.37 14.23
14.5913.94
13.
9
114.1314.92
14.92
14.51
13.5414.17
14.53
12.
7
3
12.13
14.9115.
0
6
14.97
14.99
16.6716.1516.
4
0
15.90
14.77
14.
7
7
14.2014.33
14.35
1
4
.
1
3
4' SIDEWALK
4' SIDEWALK
5' SIDEWALK
0.7%1.5%2.9%
0.6%0.5%1.9%1.0%3.2%2.0%2.8%
2.3%
1.8%
2.0%
2.9%0.2%0.6%0.5%0.5%10' SIDEWALK4' SIDEWALKLOT 1
TRACT A
LOT 1 EXISTING 8' TRAIL(12.40)(11.88)HOBBIT ST
13.31
LOT 1
LOT 1
13.35
13.941
3
.
8
1
6' SIDEWALK
0.7%0.5%
13.90 12.913.8%2.0%
2.0%
1.5%
3.5%
FFE=16.50 FFE=16.67
FFE=15.65
FFE=15.00
FFE=15.00
FFE=14.83
FFE=14.83
FFE=15.00
FFE=15.00
FFE=15.43FFE=15.43
FFE=15.82FFE=15.82
PROPOSED 4'
CONCRETE PAN
PROPOSED 4'
CONCRETE PAN
PROPOSED 4'
CONCRETE PAN
PROPOSED
AREA DRAIN
PROPOSED
AREA DRAIN 26' EMERGENCYACCESS EASEMENT26' EMERGENCY ACCESS EASEMENT
48' SANITARY SEWER EASEMENT
NATURAL AREA
BUFFER48' SANITARY SEWER EASEMENTPROPOSED 4'
CONCRETE PAN
STORM DRAIN 1
SEE SHEET C 620
TIE TO EXISTING
CURB & GUTTER
EXISTING
30" VERTICAL
CURB & GUTTER
STORM DRAIN 1-6
SEE SHEET C 622
PROPOSED 4'
CONCRETE PAN15.2615.38
13.61 10.
5
2
2.0%
2.0%
PROPOSED
FOREBAY
1
6
.
6
0
BUILDING 18 BUILDING 17
BUILDING 16
BUILDING 15
BUILDING 14
BUILDING 13
BUILDING 12
BUILDING 11
BUILDING 10
BUILDING 9
BUILDING 4 BUILDING 5
BUILDING 813.2013.
8
3
16.
4
0 14.3215.981
5
.
7
0
1
5
.
6
22.0%2.0%2.0%2.8%
3.6%
14.00
10.409.72
9.87
13.53 14.2414.5012.2214.11
10.85
13.
7
2
10.
3
710.620.5%0.8%0.6%13.9814.6914.99
PROPOSED 2'
CONCRETE PAN
PROPOSED
AREA DRAIN
PROPOSED
AREA DRAIN
PROPOSED
AREA DRAIN
14.91
1
4
.
8
9
14.90
14.98
15.53
15.7215.0914.5614.2214.17
14.05
14.51 14.4515.3415.2115.23
15.
4
2
14.7414.66
14.6814.9114.
5
0
13.871
3
.
7
9
13.54
13.69
13.28
13.
1
7
13.68
13.66
13.71
13.75
12.
9
4
12.
8
8
13.1713.
0
2
13.03
13.22
12.9112.8513.34
13.41 13.611
3
.
5
5
13.5613.661
3
.
5
913.5214.2114.23
13.0614.11
13.95
1
4
.
5
6
12.61
LP
14.58
11.59
STORM DRAIN 1-5
SEE SHEET C 621
STORM DRAIN 1-6
SEE SHEET C 621
PROPOSED 1'
SIDEWALK
CHASE
PROPOSED 1'
SIDEWALK CHASE
PROPOSED 1'
SIDEWALK CHASE
PROPOSED 1'
SIDEWALK CHASE
PROPOSED 2'
SIDEWALK CHASE
PROPOSED 1'
SIDEWALK CHASE
PROPOSED 1'
SIDEWALK CHASE
PROPOSED 1'
SIDEWALK CHASE
PROPOSED 1'
SIDEWALK CHASE
29' HALF ROW
PROPOSED
STAIRS
1.6%1.5%14.4814.9815.53
15.59
17.34
17.4017.5017.5017.4617.40
15.65
15.59
14.76
14.
2
014.7314.431
4
.
6
8
17.
5
0
17.4017.50
0.8%1.5%15.83
16.
5
0 15.921.8%PROPOSED
STAIRS
PROPOSED 2'
SIDEWALK CHASE
PROPOSED
LANDSCAPE WALL
PROPOSED 2'
CONCRETE PAN
(13.06)13.10MATCH EXISTING
PAVEMENT
AREA DRAINS
SEE SHEET C 601-C 606
PROPOSED 1'
SIDEWALK CHASE
PROPOSED 1'
SIDEWALK CHASE17.5016.8317.
4
0
15.5315.59 14.1315.
4
5
14.2014.0214.0214.5913.4515.2615.3815.751
6
.
8
3 15.2715.2015.1315.1314.6614.1213.88
14.371
4
.
4
3
14.6214.5814.5814.
4
9
13.
9
514.4914.3714.69
14.7514.67
14.64
14.66
14.58
14.99
15.4715.5615.0316.7516.1716.75 16.8316.8315.3416.8316.8316.8316.8316.8314.2813.86MATCH EXISTING
SIDEWALK
(13.52)MATCH EXISTING
PAVEMENT
14.5214.2814.1416.0714.7315.0313.
9
7 13.4713.5413.1112.73(12.86)12.4712.4412.2511.96 12.1812.15
12.06
12.40(12.48)(12.27)(12.22)(1
3
.
2
5
)
13.14 12.3613.0113.0113.0412.03 12.0513.1614.9115.1515.4915.1510.7312.1411.1914.9215.4915.3015.4915.4915.4915.1715.
4
9 14.6614.6015.10
14.24 14.2714.77
14.1214.1015.1514.
6
6
15.
4
9
15.
1
5
14.
6
2 14.5813.9914.0013.
9
2
13.
9
9
13.
7
3
13.42
13.
4
9
13.
4
2
13.
6
4
12.
4
2
12.
3
4
12.09
14.
5
6
14.
7
7
15.
1
0
15.
1
0
15.
1
0
15.
0
6
14.
9
1
15.
1
0
15.
1
0
14.
5
6
15.
1
0
15.
1
0
13.
5
6
13.
6
5
12.
8
2
12.
7
0
14.
7
7
14.
9
4
15.
4
9
15.
4
9
15.
4
9
15.
4
9
15.
1
5
14.
3
9
14.
8
114.9313.
7
7
13.85
14.4714.
7
7 15.1515.4915.8215.
8
2
14.
4
8
14.
5
8
14.
5
7
14.
5
5
14.
6
4
13.
9
1 13.8213.
3
7
14.26
14.09 14.01
13.74
13.14
14.41 13.88
13.79 13.77
13.86 14.32
14.5714.44
14.49 14.41
14.0413.61
14.15
14.10
14.
2
7
14.3213.64
13.7213.86
13.94
13.80
14.71
14.62
1
4
.
5
7
14.
6
6
15.1015.06
14.92
15.55
15.65
14.4114.9815.44
15.
2
0
14.6914.03
14.
7
0
15.3815.77
15.86
15.84
15.70
15.30
16.6716.02
15.8415.84
16.03
16.
5
714.9715.9315.3515.3515.2615.8416.5016.1416.161
6
.
5
0 15.911
5
.
3
3
14.8915.361
6
.
0
7
1
6
.
5
7
16.6715.8416.0016.521
6
.
6
7
1
6
.
1
7
1
6
.
0
7
1
6
.
6
716.5715.9116.4116.5015.9116.0116.501
5
.
8
3 16.0016.5016.4115.9115.9115.921
6
.
5
0
15.8313.92LP15.12HP14.18LP16.0716.6716.571
6
.
0
8
1
6
.
6
716.171
6
.
0
0
16.00
15.3815.4315.3816.0116.0116.1716.67
16.671
6
.
5
7
16.01
16.07
16.57
14.6314.07 14.9215.55
1
5
.
6
5
1
5
.
6
5
1
5
.
5
515.5515.6515.551
4
.
3
114.0514.67
14.
3
0
14.6714.33
14.29 11.
2
2
13.7113.711
0
.
7
1
14.33 12.76
9.9211.0110.29
10.18
9.95
10.41
10.
8
810.6816.01
16.
0
0
16.00
16.00
1
6
.
6
7
16.67 16.1716.01
16.01
16.62
16.07
1
6
.
5
716.671
6
.
0
016.0016.00
16.01
15.38
15.48
14.88 14.32
15.94
16.00
15.55
15.55
15.55
15.65
14.
0
2
14.03
1
4
.
0
3
15.55
15.6515.55
15.55
1
5
.
5
5
15.1513.5614.98
15.00
14.34
15.6515.5515.39
14.98
14.71
14.72
15.65
15.5515.31
15.18
15.31
15.65
15.00
14.68
14.69
14.08
15.3115.
6
5
15.5515.31
15.65 15.18 14.10
14.
3
1
14.40
15.
0
0
14.89
14.89
14.81
13.53
13.
5
4
14.52
15.40
15.
5
515.6513.00
14.50
14.07
14.50
14.41
14.50
14.50
14.50
14.50
14.07
14.5013.3012.52LP13.32
13.9513.
7
5
14.50
14.17
PROPOSED
RAIN GARDEN
UNDERDRAIN 1
SEE SHEET C 626
14.
6
7
14.6714.
6
7
14.
6
7
14.
5
7
14.
6
7
14.
6
7
14.
2
2
14.
6
7
14.
6
7
12.70
12.71
12.72
1
2
.
7
3
14.
3
3
14.
6
7
13.
5
3
14.
0
7
14.01
13.
2
0
13.18
13.4814.33
14.
0
5 14.0812.41
8.50
8.50
8.5012.9112.1613.83 13.6714.6714.33
14.
1
2
14.04
13.71
13.9813.9214.2214.3013.74
14.33
14.67 14.67
14.3314.22
14.15
14.3314.0713.5514.06 14.0613.
5
4
13.54
13.10HP13.6714.0913.95
14.57
14.67
14.06
14.67
14.45
14.67
14.67 14.67
14.67 14.67
14.10
14.67
8.
5
0
12.5912.79
8.50
12.79
9.25
12.79
8.5012.919.2312.79
8.26 (8.08)
9.54
9.749.979.77
11.
4
5
11.25
11.2411.4412.04
12.9114.6514.7715.
1
0
11.7611.21
11.0111.21 10.94
11.14
13.1314.7914.7715.
1
0 12.519.77
10.60 10.47
10.1910.019.89
9.72
9.88
10.60
10.60
10.58 (9.62)(9.67)
12.
2
6
13.
6
9
12.
8
5
LP
13.
2
8
13.
8
81.9%1.1%1.2%4.5%4.0%2.
7
%1.9%1.0%1.0%2.0%0.7%1.5%2.0%1.5%
1.5%
0.5%
2.1%
1.8%14.2014.
7
9
14.432.4%2.0%2.0%2.1%2.0%2.0%
3.2%2.0%
2.8%
4.0%
1.5%
2.0%1.5%
1.2%4.5%1.5%2.5%2.5%1.9%PROPOSED
TRENCH DRAIN
1.7%
2.0%
3.2%
1.5%
1.5%
2.0%2.0%
2.0%
2.0%
1.
6
%0.5%0.5%1.5%2.0%2.0%0.5%0.9%0.9%4.5%1.6%
10.00
10.20
10.
3
6
11.35
13.10
8.96
0
.
5%
2.0%1.6%1.5%3.8%3.1%0.6%3.1%1.4%0.8%1.6%PROPOSED
STAIRS
PROPOSED
STAIRS
PROPOSED
STAIRS
PROPOSED
STAIRS
PROPOSED
STAIRS
PROPOSED
STAIRS
PROPOSED
STAIRS
PROPOSED
STAIRS
PROPOSED 4'
CONCRETE PAN
PROPOSED 2'
SIDEWALK CHASE
PROPOSED
LANDSCAPE WALL
PROPOSED
AREA DRAIN1.5%1.5%2.0%0.5%2.0%
2.0%2.0%(10.82)PROPOSED 2'
SIDEWALK CHASE
0.5%
PROPOSED 2'
SIDEWALK CHASE 0.6%16.
5
7
13.91 14.131
4
.
5
0 (8.13)(8.00)(11.89)
4:1
GARAGE 4
GARAGE 515.46HPROOF DRAINS
SEE SHEET C 601-C 606
14.62
PROPOSED
STAIRS
15.2016.20FLUSH
CURB
14.830.7%PROPOSED
STAIR
15.15
15.1014.7715.1514.77
2.0%
2.0%
2.0%2.0%
2.0%
2.0%
2.0%2.0%2.0%2.0%2.0%2.0%2.0%2.0%2.0%2.0%2.0%2.0%2.0%2.0%15.1014.7711.3012.3012.30PROPOSED
LANDSCAPE WALL
14.17
12.
4
2
11.33
10.75
13.1314.
6
7
PROPOSED
STAIRS
PROPOSED
STAIRS
13.1213.61
PROPOSED
AREA DRAIN
14.33
14.3314.6714.33 14.
3
3
14.67
14.17 14.17
14.50
ROOF DRAINS
SEE SHEET C 601-C 606
PROPOSED
CONCRETE WALK w/
THICKENED EDGE
PROPOSED
CONCRETE WALK w/
THICKENED EDGE
COVERED BIKE PARKING
14.85
14.8814.56PROPOSED 1'
SIDEWALK CHASE
ASHLAR DRAREA DRAINS
SEE SHEET C 601-C 606
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
C 502GRADING PLAN14
( IN FEET )
0
1 INCH = 20 FEET
20 20 40 60
NORTH
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
PROPOSED SLOPES
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL
UNKNOWN UNDERGROUND UTILITIES.
2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD 88. SEE COVER SHEET FOR
BENCHMARK REFERENCES.
4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE
FINISHED GRADE ELEVATIONS.
5.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE CITY REGULATED 100-YR
CANAL IMPORTATION FLOODPLAIN/FLOODWAY AS WELL AS THE FEMA REGULATED
SPRING CREEK 100-YR FLOODPLAIN/FLOODWAY. ANY DEVELOPMENT WITHIN THE
FLOODPLAIN MUST COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF
CITY MUNICIPAL CODE. THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT
FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE
PERMIT FEES PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF
STRUCTURES, GRADING, FILL, DETENTION PONDS, BIKE PATHS, PARKING LOTS,
UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE
CITY OF FORT COLLINS FLOODPLAIN LIMITS AS DELINEATED ON THE FINAL
SUBDIVISION PLAT.
6.ANY CONSTRUCTION ACTIVITIES, NONSTRUCTURAL DEVELOPMENT (BRIDGES,
SIDEWALKS, CULVERTS, VEGETATION, CURB CUTS, GRADING, ETC.) IN THE
REGULATORY FLOODWAY MUST BE PRECEDED BY A NO RISE CERTIFICATION,
WHICH MUST BE PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN THE
STATE OF COLORADO.
7.NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE
FLOODWAY, WHETHER TEMPORARY (DURING CONSTRUCTION) OR PERMANENT.
8.ANY PEDESTRIAN BRIDGES IN THE FLOODWAY THAT ARE NOT ABLE TO PASS THE
100-YR FLOW ARE REQUIRED TO BE "BREAKAWAY" AND TETHERED.
NOTES:
PROPOSED STORM INLET
2.0%
(47.45
)
EXISTING SPOT ELEVATION
EXISTING LOT LINE
PROPOSED CONCRETE
CROSS PAN (TYP.)
33.43
EXISTING RIGHT OF WAY
PROPOSED LOT LINE
PROPOSED RIGHT OF WAY
LEGEND:
PROPOSED GRADE BREAK
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
SEE SHEET C 504SEE SHEET C 501SEE SHEET C 505C 501 C 502
C 503 C 504
C 506 C 505C 505PROPOSED 2' PAN
w/ 6" CURBS
D
/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /STSTSTSTSTSTSTSTSTSTUP
6' SIDEWALK6' SIDEWALK
9' SIDEWALK
6' SIDEWALK
6' SID
E
W
A
L
K
UD
UD
UD
UD
FDC
NYLOPLAST
DO NOT POLLUTE DRAINS TO WATERWAYS
17.
2
8
17.1717.15
17.20
16.66
16.66
16.77
16.
7
8
17.11
17.10
16.32
16.66 16.1216.
0
416.1316.1816.33
16.55
16.39
17.16
19.00
17.58
15.5417.051.5%1.5%3.0%2.5%1.4%2.5%2.0%2.0%2.0%
0.9%S SHIELDS STTRACT C
LOT 1
SPRIN
G
C
R
E
E
K
EXIST
I
N
G
S
P
R
I
N
G
C
R
E
E
K
T
R
A
I
LEXISTING SIDEWALKEXISTING SIDEWALKTRACT B2.0%15.8517.16
5:16:19:14
:
1
7:1 6:1FFE=17.27
FFE=17.49
PROPOSED 4'
CONCRETE PAN
PROPOSED 2'
CONCRETE PAN
PROPOSED 2'
SIDEWALK CHASE
PROPOSED
AREA DRAIN
EXISTING 30"
STORM DRAIN
PROPOSED
AREA DRAIN
31' EMERGENCY
ACCESS EASEMENT
33' WATER EASEMENT
PROPOSED 4'
SIDEWALK CULVERT
PROPOSED 2'
SIDEWALK
CHASE
FEMA 100-YR
HIGH RISK
FLOOD FRINGE
PROPOSED 2'
CONCRETE PAN
PROPOSED STORM
CHAMBERS
STORM DRAIN 4-4A
SEE SHEET C 624
STORM DRAIN 4
SEE SHEET C 624
STORM DRAIN 4-4
SEE SHEET C 624
STORM DRAIN 5
SEE SHEET C 625
STORM DRAIN 4
SEE SHEET C 624
STORM DRAIN 6
SEE SHEET C 626
9' SIDEWALK 16.3016.362.0%1.5%1.8%1
6
.
7
0
BUILDING 3
POND OVERFLOW
CHANNEL
WQ ELEV. = 5012.20
100YR ELEV. = 5014.91
16.83
16.87
1
6
.
2
2
1
6
.
1
7
12.00
0.5%
17.
0
3 16.2716.23
BUILDING 1
16.14
15.99
15.83
15.65
15.
6
3
15.78 15.62
15.67
15.
7
0
15.91
15.90
16.0216.
5
0
16.46
16.49
16.
4
516.3816.
3
9
16.45
16.92
16.9416.8917.00
16.90
16.4316.46
16.23
16.8716.5116.16
16.
2
5
16.45
16.
0
0
15.84
0.5%
16.92
16.10
PROPOSED 2'
SIDEWALK CHASE
PROPOSED 2'
SIDEWALK CHASE
PROPOSED
AREA DRAIN
(18.46)
(18.45)
18.94
16.
6
9
18.80
17.
9
0
18.34
16.00
16.06
15.
9
3
15.
0
9
15.
1
2
15.
8
32.2%0.5%16.
3
7
15.76
PROPOSED
AREA DRAIN
(18.41)
(18.40)
(18.32)
(18.34)(17.79)(17.08)
(17.43)(17.45)(17.90)(17.62)(18.47)
PROPOSED
LANDSCAPE WALL
PROPOSED 1'
SIDEWALK CHASECULVERTS
SEE SHEET C 601-C 606
PROPOSED 2'
CONCRETE PAN
16.
2
6
16.33
15.33
15.33
16.4116.5015.33
15.2816.6616.7416.4216.3216.54
17.
2
0
17.12
16.
5
5
16.
0
0
15.
8
5
15.4315.
3
7
15.
2
9
15.
6
2
15.66
16.
2
3
16.
2
6
16.3116.35HP17.
1
6
17.
0
4
16.
7
5
17.16
16.65
16.
1
2
16.
2
2
17.
1
0
16.9216.
0
2
16.
2
6
16.
2
4
16.82
15.
9
8
17.40
16.78
17.
1
9
17.
2
717.
2
7
17.
2
7
17.
1
7
18.33
PROPOSED
STAIRS
17.
2
0
17.
2
1
17.
2
1
17.27 17.2017.
2
7
17.25
17.
2
7
17.
0
7
PROPOSED 2'
CONCRETE PAN
PROPOSED
FLUSH CURB
17.
1
6
17.
2
5
17.
2
5
17.
0
6
17.
2
7
17.28 17.33
17.5617.47
17.28
17.26
17.27
17.27
17.27
1
7
.
5
9
17.58
17.42
16.28
16.
7
8
16.84
16.9417.57
16.98
17.27 17.27
17.37
17.1316.58
17.27
17.27(17.73)17.22
17.27
17.27 17.2716.8817.19
16.2817.1417.10
18.09
18.13
16.71
18.21
18.32
17.2117.99 18.00
17.87
17.80
17.98
16.8317.76
18.22
16.24
16.51
1
7
.
0
1
15.9415.71
15.30
15.84
15.
1
8
15.09
14.
7
1
14.05
13.0015.0715.2215.4815.5315.4115.89
16.25 16.13
16.05
11.26
11.34
11.08
11.05 10.95
11.08
17.25
17.41
11.65
11.31
12.83
13.00
12.18
12.19
13.60
14.61
14.75
15.29
15.14
14.60
16.23
16.26
16.81
16.86
17.34
17.31
16.83
16.98
17.01 17.59
17.
5
4
17.57
17.39
17.27
17.
2
5
17.39
17.33
17.
5
7
17.62
17.6017.39
17.43
17.47
17.
0
9
17.
1
4
17.52
17.52
16.89
16.88
17.28 0.5%17.550.5%1.5%2.0%0.5%1.5%1.6%1.5%2.0%2.5%2.0%
0.5%
0.5%
0.8%2.0%4.0%3.8%2.0%2.0%0.5%2.0%1.5%0.5%1.5%5.6%
0.5%
0.5%2.0%1.3%1.3%1.5
%1.3%0.5%
0.8%1.5%
1
.
5%
2.1%
1.6%2.2%
1.6
%
15.72
15.64 1.5%1.5%0.4
%0.9%2.0%0.5%0.5%0.5%3.0%0.
5
%1.5%0.5%0.5%
15.48
0.5%0.5%15.571.0%17.9917.8617.7517.72PROPOSED 2'
CONCRETE PAN
PROPOSED
LANDSCAPE
WALL
1.5%
1
8
.
3
4
2.8%1.9%(17.84)
EXISTING 30"
VERTICAL
CURB & GUTTER
EXISTING 30"
VERTICAL
CURB & GUTTER
TIE TO
EXISTING
TIE TO
EXISTING
MATCH
EXISTING
TIE TO
EXISTING
TIE TO
EXISTING 1.0%
0
.
6%
PROPOSED MAINTENANCE
ACCESS PATH 5:14:
1
7:1PROPOSED
FLUSH CURB
TIE TO
EXISTING
FEMA 100-YR
FLOODWAY
DETENTION
POND 2
17.30
ROOF DRAINS
SEE SHEET C 607-C 608
ROOF DRAINS
SEE SHEET C 607-C 608
ROOF DRAINS
SEE SHEET C 607-C 608
17.27
17.37
17.2717.27
4'x4' ADA
LANDING
4'x4' ADA
LANDING
1
7
.
5
517.56
4'x4' ADA
LANDING
4'x4' ADA
LANDING
17.53
17.41PROPOSED 1'
SIDEWALK CHASE
PROPOSED 1'
SIDEWALK CHASE
17.27
PROPOSED 1'
SIDEWALK CHASE
PROPOSED
TRENCH DRAIN
17.24
16.79
17.71 17.71
17.71
17.71
PROPOSED
AREA DRAIN
17.
2
417.24
16.
6
6
1
6
.
7
0
16.78
17.
2
5
17.
2
7
17.
2
7
17.
2
7
17.65
17.69
17.66
17.6817.6716.7016.60
W STUART ST
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
C 503GRADING PLAN15
( IN FEET )
0
1 INCH = 20 FEET
20 20 40 60
NORTH
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
PROPOSED SLOPES
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL
UNKNOWN UNDERGROUND UTILITIES.
2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD 88. SEE COVER SHEET FOR
BENCHMARK REFERENCES.
4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE
FINISHED GRADE ELEVATIONS.
5.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE CITY REGULATED 100-YR
CANAL IMPORTATION FLOODPLAIN/FLOODWAY AS WELL AS THE FEMA REGULATED
SPRING CREEK 100-YR FLOODPLAIN/FLOODWAY. ANY DEVELOPMENT WITHIN THE
FLOODPLAIN MUST COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF
CITY MUNICIPAL CODE. THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT
FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE
PERMIT FEES PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF
STRUCTURES, GRADING, FILL, DETENTION PONDS, BIKE PATHS, PARKING LOTS,
UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE
CITY OF FORT COLLINS FLOODPLAIN LIMITS AS DELINEATED ON THE FINAL
SUBDIVISION PLAT.
6.ANY CONSTRUCTION ACTIVITIES, NONSTRUCTURAL DEVELOPMENT (BRIDGES,
SIDEWALKS, CULVERTS, VEGETATION, CURB CUTS, GRADING, ETC.) IN THE
REGULATORY FLOODWAY MUST BE PRECEDED BY A NO RISE CERTIFICATION,
WHICH MUST BE PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN THE
STATE OF COLORADO.
7.NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE
FLOODWAY, WHETHER TEMPORARY (DURING CONSTRUCTION) OR PERMANENT.
8.ANY PEDESTRIAN BRIDGES IN THE FLOODWAY THAT ARE NOT ABLE TO PASS THE
100-YR FLOW ARE REQUIRED TO BE "BREAKAWAY" AND TETHERED.
NOTES:
PROPOSED STORM INLET
2.0%
(47.45
)
EXISTING SPOT ELEVATION
EXISTING LOT LINE
PROPOSED CONCRETE
CROSS PAN (TYP.)
33.43
EXISTING RIGHT OF WAY
PROPOSED LOT LINE
PROPOSED RIGHT OF WAY
LEGEND:
PROPOSED GRADE BREAK
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
SEE SHEET C 501
SEE SHEET C 504SEE SHEET C 506
C 501 C 502
C 503 C 504
C 506 C 505C 505
XXXXXMCCOY JOHN H/SHERRY P
1900 S SHIELDS STBBBBBBBBBBBBBB BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBXBBBBBB6' SIDEWALK
6' SID
E
W
A
L
K
10' SID
E
W
A
L
K
11' SIDEWALK
10' SIDEWALK
UD UD UD
UD
13.79
14.
7
2
14.72
16.
0
6
15.35
15.
7
6
16.47
16.5515.15
14.84
14.25
13.72
13.32
13.33
14.17
13.23
12.2914.5815.29
14.51
EXISTING
S
P
R
I
N
G
C
R
E
E
K
T
R
A
I
L
15.
0
6
14.97
15.
6
4
16.
4
0
8.1114.17
2.0%1.7%2.1%2.2%0.5%
1.9%
2
.
8%
0.6%
0.9%
SPRING CRE
E
K
TRACT B
LOT 1
LOT 1
0.5%15.852.4%2.0%9' SIDEWALK
2.0%10:16:14:1
6.
7
9
FFE=14.83
EXISTING FEMA
100-YR HIGH RISK
FLOOD PLAIN
PROPOSED 4'
CONCRETE PAN
PROPOSED 4'
CONCRETE PAN
PROPOSED 4'
CONCRETE PAN
PROPOSED
RAIN GARDEN
26' EMERGENCY ACCESS EASEMENT
33' WATER EASEMENT
NATURAL AREA
BUFFER
PROPOSED 4'
CONCRETE PAN
PROPOSED RETAINING
WALL (RE: LANDSCAPE)
PROPOSED 2'
CONCRETE PAN
PROPOSED STORM
CHAMBERS
STORM DRAIN 2
SEE SHEET C 623
FEMA 100-YR
FLOODWAY
PROPOSED 6'
CONCRETE PAN
NATURAL AREA
BUFFER
13.61
13.572.0%2.0%16.3016.
1
8 15.7416.362.0%2.0%2.0%BUILDING 9
100YR ELEV. = 5011.604:14:14:14:112.8612.97
12.53
1.9%1.9%14.6914.69
14.0414.3113.
8
2
12.95
12.
8
4
13.50
13.65
13.
4
3
1.9%0.5%
13.53
12.34
15.01
14.89
15.07
14.86
14.23
14.20
1
4
.
0
5
15.
9
0
15.86
15.90
16.02
16.27 16.1614.80
13.
8
8
14.04
13.33
13.23
13.28
13.22
12.79
12.57
12.
5
4
12.5913.0612.92
12.00
11.98
12.95
12.87
13.
2
9
13.74
13.80
14.59
14.82
16.
0
0
15.84
12.
5
9
12.59
12.70
14.1813.97
PROPOSED
TRENCH DRAIN
PROPOSED 2'
SIDEWALK CHASE
2.0%
16.00
15.94
16.00
13.002.0%2.8%
1.3%1.9%16.4216.321
7
.
5
9
16.51
1
7
.
0
1
15.9415.14
14.60 2.0%
0.5%1.5%
1
.
5%1.5%PROPOSED 6'
CONCRETE PAN
PROPOSED STAIRS
15.3315.
9
116.5014.
8
6 16.
0
0
16.
5
7
16.
6
7
15.
5
0
15.39
15.
1
8
14.
8
0
14.
3
9
14.
1
9
14.
3
1
14.
8
3
15.
4
6
15.
5
1
15.
4
6
15.
5
1
15.
7
0
15.
6
3
16.
1
9
16.
4
1
16.
4
7
17.
1
0
17.
0
8
16.
3
4 15.4414.28
14.7815.2116.57
15.38
16.67
PROPOSED
STAIRS
14.711
4
.
2
3
14.20
14.77
13.89 13.41
13.41
13.32
13.59 14.09
14.16 14.19
14.10
13.92
14.33
14.73
14.98
14.17
13.6513.6514.1113.5213.5113.57
13.4413.9513.8813.3313.
5
4
13.91
13.35PROPOSED
CURB CUT 14.1313.3913.4913.3713.
5
9
1
4
.
5
0
14.
2
4
13.5013.521
3
.
3
6
14.49
14.50
1
3
.
4
2
12.9512.
8
2
12.6511.9811.9911.9011.40
11.40
11.958.5012.8512.5012.7713.2413.14
12.9412.48
12.2813.
2
6
8.00 8.0012.13
7.
9
78.8310.1310.5812.58
12.429.979.9
7
1
2
.
4
2
10.42
8.65
10.1310.5812.5813.6212.6410.64
10.198.198.09
10.6412.5913.1410.9312.
9
3
10.48
8.488.30
8.3410.1910.488.5610.9312.
9
3
10.488.3610.7011.0012.9311.0014.
3
3 7.717.297.026.85STORM DRAIN 5
SEE SHEET C 625
14.55
14.00
14.7314.5615.51 14.9114.5813.9613.5314.4714.4214.48
15.2315.35 15.3215.
2
7
14.9215.0115.2616.
1
2
15.50
16.89
15.67
16.50
15.36
13.90
16.38
13.04
14.52
14.39
13.8413.9813.0913.15
8.50
1.5%2.0%2.0%2.0%0.5%1.3%2.0%0.6%0.5%1.9%0.5%2.0%2.0%2.0%0.5%
12.
6
2
12.7413.000.5%1.5%2.0%2.0%1.6%1.0%0.9%0.5%1.
2
%
1.5%
1.5%1.9%1.7%
0.9%1.8%7:10.5%
0.5
%
2.0
%2.0%
6.758.0012.1312.8013.
1
1
100YR ELEV. = 5011.37
DETENTION
POND 1
17.71
17.71
1
3
.
7
8
12" CURB
12.40TBC12.40TBCW STU
A
R
T
S
T
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
C 504GRADING PLAN16
( IN FEET )
0
1 INCH = 20 FEET
20 20 40 60
NORTH
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
PROPOSED SLOPES
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL
UNKNOWN UNDERGROUND UTILITIES.
2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD 88. SEE COVER SHEET FOR
BENCHMARK REFERENCES.
4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE
FINISHED GRADE ELEVATIONS.
5.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE CITY REGULATED 100-YR
CANAL IMPORTATION FLOODPLAIN/FLOODWAY AS WELL AS THE FEMA REGULATED
SPRING CREEK 100-YR FLOODPLAIN/FLOODWAY. ANY DEVELOPMENT WITHIN THE
FLOODPLAIN MUST COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF
CITY MUNICIPAL CODE. THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT
FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE
PERMIT FEES PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF
STRUCTURES, GRADING, FILL, DETENTION PONDS, BIKE PATHS, PARKING LOTS,
UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE
CITY OF FORT COLLINS FLOODPLAIN LIMITS AS DELINEATED ON THE FINAL
SUBDIVISION PLAT.
6.ANY CONSTRUCTION ACTIVITIES, NONSTRUCTURAL DEVELOPMENT (BRIDGES,
SIDEWALKS, CULVERTS, VEGETATION, CURB CUTS, GRADING, ETC.) IN THE
REGULATORY FLOODWAY MUST BE PRECEDED BY A NO RISE CERTIFICATION,
WHICH MUST BE PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN THE
STATE OF COLORADO.
7.NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE
FLOODWAY, WHETHER TEMPORARY (DURING CONSTRUCTION) OR PERMANENT.
8.ANY PEDESTRIAN BRIDGES IN THE FLOODWAY THAT ARE NOT ABLE TO PASS THE
100-YR FLOW ARE REQUIRED TO BE "BREAKAWAY" AND TETHERED.
NOTES:
PROPOSED STORM INLET
2.0%
(47.45
)
EXISTING SPOT ELEVATION
EXISTING LOT LINE
PROPOSED CONCRETE
CROSS PAN (TYP.)
33.43
EXISTING RIGHT OF WAY
PROPOSED LOT LINE
PROPOSED RIGHT OF WAY
LEGEND:
PROPOSED GRADE BREAK
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
SEE SHEET C 502
SEE SHEET C 503SEE SHEET C 505C 501 C 502
C 503 C 504
C 506 C 505C 505
MH
UD
S
UDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMM
MHXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXUDUDUDUDUDUDUDUDTRACT AEXISTING 8' TRAILCANAL IMPORTATIONWALLENBERG DRPROPOSED
RAIN GARDEN
RAIN GARDEN BIOMEDIA AREA
(MIN. FLAT SURFACE = 4,353 SF
DESIGN FLAT SURFACE = 6,646 SF)
CITY OF FORT COLLINS
100-YR FLOODWAY
UNDERDRAIN 1
SEE SHEET C 626
FEMA 100-YR
HIGH RISK
FLOOD FRINGE
CITY OF FORT
COLLINS 100-YR
FLOODPLAIN
8.50
8.50
8.26 (8.08)(9.62)(9.67)
10.00
(8.13)(8.00)(11.89)(11.83)(11.92)
8.50
4:1
UDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDXXXXXXXXXXXXXXXXXXXXXXXXSTWINNE GRANT R/JOHNELLE S
1821 WALLENBERG DR
ERIKSEN CHRISTOPHER M
1825 WALLENBERG DRBXBBBBBBBBBUDUD12.
7
7
EXISTING 8' TRAILCANAL IMPORTATIONTRACT A
0.5%6.79PROPOSED
RAIN GARDEN
PROPOSED 12' ACCESS ROAD
STORM DRAIN 5
SEE SHEET C 625
STORM DRAIN 5-2
SEE SHEET C 625
STORM DRAIN 3
SEE SHEET C 623
CITY OF FORT COLLINS
100-YR FLOODWAY
FEMA 100-YR
HIGH RISK
FLOOD FRINGE
CITY OF FORT
COLLINS 100-YR
FLOODPLAIN
12.
2
2
POND
OVERFLOW PATH
1
6
:
112.8612.53
12.
8
2
1.9%12.34
12.
5
911.9011.40
11.40
11.958.5012.8512.5012.7713.2413.14
12.9412.48
12.288.0012.13
6.858.50
2.0%0.5
%(11.92)
PROPOSED
MAINTENANCE
ACCESS PATH EMERGENCY
OVERFLOW
WEIR1.8%TIE TO EXISTING
CONCRETE TRAIL (6.76)(6.91)8.229.108.2612.806.75
12.8011.3411.529.3511.8012.8011.8011.6611.8412.4412.1912.2712.2012.357.267.8
512.0012.
1
38.0012.138.508.5012.5812.3412.8012.
7
4
12.
6
8
13.
1
0
13.
1
1
1.5%1.5%1.1%2.5%2.0%4.5%0.5%2.4%0.8%10.0%5:1
6:1
7:112.805.0%EXI
S
T
I
N
G
S
P
R
I
N
G
C
R
E
E
K
T
R
A
I
L
EX
I
S
T
I
N
G
S
P
R
I
N
G
C
R
E
E
K
T
R
A
I
L
FEMA 100-YR
FLOODWAY
EXISTING FEMA
100-YR HIGH RISK
FLOOD PLAIN
SPR
I
N
G
C
R
E
E
K
100YR ELEV. = 5011.37
GARAGE 6
12" CURB
12.40TBC12.40TBCPROPOSED
FLUSH CURB
PROPOSED
COVERED BIKE
PARKING
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
C 505GRADING PLAN17
( IN FEET )
0
1 INCH = 20 FEET
20 20 40 60
NORTH
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
PROPOSED SLOPES
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL
UNKNOWN UNDERGROUND UTILITIES.
2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD 88. SEE COVER SHEET FOR
BENCHMARK REFERENCES.
4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE
FINISHED GRADE ELEVATIONS.
5.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE CITY REGULATED 100-YR
CANAL IMPORTATION FLOODPLAIN/FLOODWAY AS WELL AS THE FEMA REGULATED
SPRING CREEK 100-YR FLOODPLAIN/FLOODWAY. ANY DEVELOPMENT WITHIN THE
FLOODPLAIN MUST COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF
CITY MUNICIPAL CODE. THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT
FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE
PERMIT FEES PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF
STRUCTURES, GRADING, FILL, DETENTION PONDS, BIKE PATHS, PARKING LOTS,
UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE
CITY OF FORT COLLINS FLOODPLAIN LIMITS AS DELINEATED ON THE FINAL
SUBDIVISION PLAT.
6.ANY CONSTRUCTION ACTIVITIES, NONSTRUCTURAL DEVELOPMENT (BRIDGES,
SIDEWALKS, CULVERTS, VEGETATION, CURB CUTS, GRADING, ETC.) IN THE
REGULATORY FLOODWAY MUST BE PRECEDED BY A NO RISE CERTIFICATION,
WHICH MUST BE PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN THE
STATE OF COLORADO.
7.NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE
FLOODWAY, WHETHER TEMPORARY (DURING CONSTRUCTION) OR PERMANENT.
8.ANY PEDESTRIAN BRIDGES IN THE FLOODWAY THAT ARE NOT ABLE TO PASS THE
100-YR FLOW ARE REQUIRED TO BE "BREAKAWAY" AND TETHERED.
NOTES:
PROPOSED STORM INLET
2.0%
(47.45
)
EXISTING SPOT ELEVATION
EXISTING LOT LINE
PROPOSED CONCRETE
CROSS PAN (TYP.)
33.43
EXISTING RIGHT OF WAY
PROPOSED LOT LINE
PROPOSED RIGHT OF WAY
LEGEND:
PROPOSED GRADE BREAK
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
SEE THIS SHEET RIGHTSEE SHEET C 502SEE SHEET C 504SEE THIS SHEET LEFT
C 501 C 502
C 503 C 504
C 506 C 505C 505
CABLE
TFO FOFOFOD / / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /XSTSTSTSTSTSTSTSTSTSTSTHILL POND CONDOMINIUMS
TRACT B
FEMA 100-YR
FLOODWAY
(18.47)
EXISTING
STORM
DRAIN EXISTING SIDEWALKSPRIN
G
C
RE
EK
EXI
STI
N
G
S
P
RI
N
G
C
R
E
E
K T
R
AIL
EXISTING FEMA
100-YR HIGH RISK
FLOOD PLAIN
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
C 506GRADING PLAN18
( IN FEET )
0
1 INCH = 20 FEET
20 20 40 60
NORTH
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
PROPOSED SLOPES
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL
UNKNOWN UNDERGROUND UTILITIES.
2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD 88. SEE COVER SHEET FOR
BENCHMARK REFERENCES.
4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE
FINISHED GRADE ELEVATIONS.
5.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE CITY REGULATED 100-YR
CANAL IMPORTATION FLOODPLAIN/FLOODWAY AS WELL AS THE FEMA REGULATED
SPRING CREEK 100-YR FLOODPLAIN/FLOODWAY. ANY DEVELOPMENT WITHIN THE
FLOODPLAIN MUST COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF
CITY MUNICIPAL CODE. THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT
FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE
PERMIT FEES PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF
STRUCTURES, GRADING, FILL, DETENTION PONDS, BIKE PATHS, PARKING LOTS,
UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE
CITY OF FORT COLLINS FLOODPLAIN LIMITS AS DELINEATED ON THE FINAL
SUBDIVISION PLAT.
6.ANY CONSTRUCTION ACTIVITIES, NONSTRUCTURAL DEVELOPMENT (BRIDGES,
SIDEWALKS, CULVERTS, VEGETATION, CURB CUTS, GRADING, ETC.) IN THE
REGULATORY FLOODWAY MUST BE PRECEDED BY A NO RISE CERTIFICATION,
WHICH MUST BE PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN THE
STATE OF COLORADO.
7.NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE
FLOODWAY, WHETHER TEMPORARY (DURING CONSTRUCTION) OR PERMANENT.
8.ANY PEDESTRIAN BRIDGES IN THE FLOODWAY THAT ARE NOT ABLE TO PASS THE
100-YR FLOW ARE REQUIRED TO BE "BREAKAWAY" AND TETHERED.
NOTES:
PROPOSED STORM INLET
2.0%
(47.45
)
EXISTING SPOT ELEVATION
EXISTING LOT LINE
PROPOSED CONCRETE
CROSS PAN (TYP.)
33.43
EXISTING RIGHT OF WAY
PROPOSED LOT LINE
PROPOSED RIGHT OF WAY
LEGEND:
PROPOSED GRADE BREAK
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
SEE SHEET C 503
C 501 C 502
C 503 C 504
C 506 C 505C 505
E
E
E
E
E
E
E
G
G
G
G
G
G
UD
UD
UD
UD
UD
UD
UD
UD
UD
BASIN F-3.1-4
INV. OUT=5012.63 (W)
INV. OUT=5012.63 (S)
FG=5016.59
UD CO 4-3.2
INV. OUT=5012.46 (W)
FG=5016.49
BASIN 4-3 (w WEIR)
INV. IN=5011.77 (N)
INV. IN=5012.25 (E)
INV. IN=5012.33 (E)
INV. OUT=5011.77 (W)
FG=5016.34
END CHAMBER 4-3.1-3
INV. IN=5012.62 (E)
INV. OUT=5012.62 (W)
FG=5016.64
END CHAMBER 4-3.2
INV. IN=5012.52 (E)
INV. OUT=5012.52 (W)
FG=5016.54
BEGIN CHAMBER 4-3.1-2
INV. IN=5012.43 (E)
INV. OUT=5012.43 (W)
FG=5016.59
BEGIN CHAMBER 4-3.2
INV. IN=5012.34 (E)
INV. OUT=5012.34 (W)
FG=5016.45
90° BEND 4-3.3
INV. IN=5012.58 (N)
INV. OUT=5012.58 (W)
FG=5016.50
90° BEND 4-3.1-1
INV. IN=5012.42 (E)
INV. OUT=5012.42 (S)
FG=5016.57
TEE 4-3.1
INV. IN=5012.33 (E)
INV. IN=5012.33 (N)
INV. OUT=5012.35 (W)
FG=5016.43
UD BEND 4-3.1
INV. IN=5012.26 (E)
INV. OUT=5012.26 (W)
FG=5016.3013.92 LF18" HDPE@ 0.50%5.16 LF
4" HDPE
@ 0.20%
98.65 LF
4" PERF HDPE
@ 0.20%7.70 LF 12" HDPE @ 0.20%
1.70 LF 12" HDPE @ 0.20%
94.12 LF
SC-740 CHAMBER
@ 0.20%
4.61 LF 12" HDPE @ 1.10%
4.75 LF 12" HDPE @ 1.85%
2.54 LF
12" HDPE
@ 0.50%
92.47 LF
SC-740 CHAMBER
@ 0.20%
5.38 LF
12" HDPE
@ 0.20%
4.75 LF
12" HDPE
@ 1.10%
STORM DRAIN 4
SEE SHEET C 624
PROPOSED 8"
PVC WATER16.66FG16.68FG16.45FG16.32
FG11.99SG11.75
SG
11.95
SG
12.18
SG
0.2%
0.2%2.0%2.0%
INSPECTION PORT
INSPECTION PORT
W STU
A
R
T
S
T
UD UD UD UD UD UD UDEEEGGG30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W
BBBBBBBBBBBBBBBBBBBBBBBBBBASIN 2-2 (w WEIR)
INV. IN=5008.11 (N)
INV. IN=5008.52 (W)
INV. OUT=5008.11 (S)
FG=5012.84
BASIN 2-3
INV. IN=5008.12 (N)
INV. IN=5008.51 (W)
INV. OUT=5008.12 (S)
FG=5012.73
BASIN 2-4
INV. IN=5008.13 (NE)
INV. IN=5008.56 (W)
INV. OUT=5008.13 (S)
FG=5012.63
END CHAMBER 2-4.2
INV. OUT=5008.98 (E)
FG=5013.05
END CHAMBER 2-2.2
INV. OUT=5008.97 (E)
FG=5013.29
BEGIN CHAMBER 2-4.1
INV. IN=5008.59 (W)
INV. OUT=5008.59 (E)
FG=5012.67
BEGIN CHAMBER 2-2.1
INV. IN=5008.54 (W)
INV. OUT=5008.54 (E)
FG=5012.87
4.75 LF 18" RCP @ 0.20%
4.75 LF 18" RCP @ 0.20%
5.38 LF
12" HDPE
@ 0.50%
64.05 LF
SC-740 CHAMBER
@ 0.60%
5.38 LF
12" HDPE
@ 0.50%
71.17 LF
SC-740 CHAMBER
@ 0.60%
STORM DRAIN 2
SEE SHEET C 623
EXISTING 30"
WATER
INSPECTION PORT
INSPECTION PORT
INSPECTION PORT
UD CO 2-3
INV. OUT=5008.96 (E)
FG=5013.35
UD TEE w CO 2-2
INV. IN=5008.57 (E)
INV. IN=5008.57 (W)
INV. OUT=5008.57 (S)
FG=5012.99
UD CO 2-2A
INV. OUT=5008.60 (W)
FG=5012.95
UD PIPE END 2-1
INV. IN=5008.07 (N)
FG=5008.07
25.39 LF
4" HDPE
@ 1.95%
5.53 LF
4" PERF HDPE
@ 0.50%
65.08 LF
4" PERF HDPE
@ 0.60%0.5%0.5%0.6%
0.6%
13.05
FG
1
2
.
5
9FG
13.00FG13.43
FG 8.46SG8.
0
0
SG8.09SG8.55SG71.17 LF
SC-740 CHAMBER
@ 0.60%
END CHAMBER 2-3.2
INV. OUT=5008.97 (E)
FG=5013.19
BEGIN CHAMBER 2-3.1
INV. IN=5008.54 (W)
INV. OUT=5008.54 (E)
FG=5012.77
5.38 LF
12" HDPE
@ 0.50%
INSPECTION PORT
PROPOSED SUBGRADE SPOT ELEVATION 33.43
PROPOSED SUBGRADE SLOPES 2.0%
PROPOSED SUBDRAIN UD
PROPOSED FINISHED GRADE SPOT ELEVATION 33.43
SG
1.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
2.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY
OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN
THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE
CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES
AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES.
3.CONTRACTOR SHALL NOTIFY THE DESIGN ENGINEER AND THE CITY OF FORT COLLINS
STORMWATER UTILITY A MINIMUM OF ONE WEEK IN ADVANCE SO AS TO ALLOW FOR
FIELD OBSERVATION AND DOCUMENTATION OF THE FOLLOWING SYSTEM ITEMS IN THE
SUBGRADE AREA:
- SUBGRADE
- INSTALLATION OF GEOTEXTILE FABRIC
- INSTALLATION OF UNDERDRAIN
- PLACEMENT AND COMPACTION OF SUB-BASE MATERIAL
- PLACEMENT AND COMPACTION OF BASE MATERIAL
4.STORMTECH CONTRACTOR SHALL MEET WITH SUPPLIER PRIOR TO INSTALLATION.
5.SUBGRADE AREAS ARE TO BE FIELD SURVEYED BY A LICENSED PROFESSIONAL. THE
DESIGN ENGINEER MUST CONFIRM THE SUBGRADE ELEVATIONS AND DIMENSIONS
PRIOR TO PLACEMENT OF GEOTEXTILE FABRIC, SUB-BASE, OR ANY OTHER MATERIAL.
6.THE CONTRACTOR SHOULD PROVIDE SLACK IN GEOTEXTILE FABRIC TO ENSURE
PROPER INSTALLATION AND AGGREGATE PLACEMENT WITHOUT DAMAGE. PROVIDE
SUFFICIENT SLACK SO THE FABRIC IS NOT TORN WHEN ROCK IS PLACED. IF TEARS
ARE SEEN OR DISCOVERED, REPAIR THEM AS RECOMMENDED BY MANUFACTURER
WITH NO LESS THAN 18 INCHES OF OVERLAP ON ALL SIDES OF THE TEAR.
7.THE CONTRACTOR SHALL, AT ALL TIMES DURING AND AFTER SYSTEM INSTALLATION,
PREVENT SEDIMENT, DEBRIS, AND DIRT FROM ANY SOURCE FROM ENTERING THE
VAULT SYSTEM.
8.SEE DETAIL SHEETS FOR ADDITIONAL DESIGN INFORMATION.
9.CONTRACTOR SHALL COORDINATE ANY NECESSARY TELEPHONE, CABLE, ELECTRIC,
GAS, IRRIGATION, ECT. LOWERINGS (OR RE-ROUTING) WITH THE RESPECTIVE UTILITY
PROVIDERS TO FACILITATE THE INSTALLATION OF THE PROPOSED STORM DRAIN AND
UTILITY SERVICES.
10.VAULT LAYOUT SHOWN IN THESE PLANS IS FOR REFERENCE ONLY. FINAL VAULT
LAYOUT AND DESIGN SHALL BE PER MANUFACTURER.
STORMTECH CHAMBER DETAILS
STORMTECH CHAMBER ISOLATOR ROW
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
NOTES:
W
PROPOSED CURB & GUTTER
PROPOSED FIRE HYDRANT
PROPOSED LOT LINE
PROJECT BOUNDARY
EASEMENT LINE
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
C 510SUBGRADE PLAN19
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
NORTH
( IN FEET )
1 inch = ft.
Feet01010
10
20 30
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
STORM
CHAMBERS 2
SHEET
OFDATE:PROJECT #:DRAWN:CHECKED:THIS DRAWING HAS BEEN PREPARED BASED ON INFORMATION PROVIDED TO ADS UNDER THE DIRECTION OF THE SITE DESIGN ENGINEER OR OTHER PROJECT REPRESENTATIVE. THE SITE DESIGN ENGINEER SHALL REVIEW THIS DRAWING PRIOR TO CONSTRUCTION. IT IS THE ULTIMATERESPONSIBILITY OF THE SITE DESIGN ENGINEER TO ENSURE THAT THE PRODUCT(S) DEPICTED AND ALL ASSOCIATED DETAILS MEET ALL APPLICABLE LAWS, REGULATIONS, AND PROJECT REQUIREMENTS.4640 TRUEMAN BLVDHILLIARD, OH 430261-800-733-7473ADVANCED DRAINAGE SYSTEMS, INC.RREVDRWCHKDESCRIPTION01/19/16JLMJLMUPDATESC-740STANDARD CROSS SECTION11/18/14JLM1 1JLM70 INWOOD ROAD, SUITE 3 | ROCKY HILL | CT | 06067860-529-8188 |888-892-2694 | WWW.STORMTECH.COMDetention Retention Water QualityACCEPTABLE FILL MATERIALS: STORMTECH SC-740 CHAMBER SYSTEMS
PLEASE NOTE:
1.THE LISTED AASHTO DESIGNATIONS ARE FOR GRADATIONS ONLY. THE STONE MUST ALSO BE CLEAN, CRUSHED, ANGULAR. FOR EXAMPLE, A SPECIFICATION FOR #4 STONE WOULD STATE: "CLEAN, CRUSHED,
ANGULAR NO. 4 (AASHTO M43) STONE".
2.STORMTECH COMPACTION REQUIREMENTS ARE MET FOR 'A' LOCATION MATERIALS WHEN PLACED AND COMPACTED IN 6" (150 mm) (MAX) LIFTS USING TWO FULL COVERAGES WITH A VIBRATORY COMPACTOR.
3.WHERE INFILTRATION SURFACES MAY BE COMPROMISED BY COMPACTION, FOR STANDARD DESIGN LOAD CONDITIONS, A FLAT SURFACE MAY BE ACHIEVED BY RAKING OR DRAGGING WITHOUT COMPACTION
EQUIPMENT. FOR SPECIAL LOAD DESIGNS, CONTACT STORMTECH FOR COMPACTION REQUIREMENTS.
NOTES:
1.SC-740 CHAMBERS SHALL CONFORM TO THE REQUIREMENTS OF ASTM F2418 "STANDARD SPECIFICATION FOR POLYPROPYLENE (PP) CORRUGATED WALL STORMWATER
COLLECTION CHAMBERS", OR ASTM F2922 "STANDARD SPECIFICATION FOR POLYETHYLENE (PE) CORRUGATED WALL STORMWATER COLLECTION CHAMBERS".
2.SC-740 CHAMBERS SHALL BE DESIGNED IN ACCORDANCE WITH ASTM F2787 "STANDARD PRACTICE FOR STRUCTURAL DESIGN OF THERMOPLASTIC CORRUGATED WALL
STORMWATER COLLECTION CHAMBERS".
3."ACCEPTABLE FILL MATERIALS" TABLE ABOVE PROVIDES MATERIAL LOCATIONS, DESCRIPTIONS, GRADATIONS, AND COMPACTION REQUIREMENTS FOR FOUNDATION,
EMBEDMENT, AND FILL MATERIALS.
4.THE SITE DESIGN ENGINEER IS RESPONSIBLE FOR ASSESSING THE BEARING RESISTANCE (ALLOWABLE BEARING CAPACITY) OF THE SUBGRADE SOILS AND THE DEPTH OF
FOUNDATION STONE WITH CONSIDERATION FOR THE RANGE OF EXPECTED SOIL MOISTURE CONDITIONS.
5.PERIMETER STONE MUST BE EXTENDED HORIZONTALLY TO THE EXCAVATION WALL FOR BOTH VERTICAL AND SLOPED EXCAVATION WALLS.
6.ONCE LAYER 'C' IS PLACED, ANY SOIL/MATERIAL CAN BE PLACED IN LAYER 'D' UP TO THE FINISHED GRADE. MOST PAVEMENT SUBBASE SOILS CAN BE USED TO REPLACE THE
MATERIAL REQUIREMENTS OF LAYER 'C' OR 'D' AT THE SITE DESIGN ENGINEER'S DISCRETION.
MATERIAL LOCATION DESCRIPTION AASHTO MATERIAL
CLASSIFICATIONS
COMPACTION / DENSITY
REQUIREMENT
D
FINAL FILL: FILL MATERIAL FOR LAYER 'D' STARTS
FROM THE TOP OF THE 'C' LAYER TO THE BOTTOM
OF FLEXIBLE PAVEMENT OR UNPAVED FINISHED
GRADE ABOVE. NOTE THAT PAVEMENT SUBBASE
MAY BE PART OF THE 'D' LAYER
ANY SOIL/ROCK MATERIALS, NATIVE SOILS, OR PER
ENGINEER'S PLANS. CHECK PLANS FOR PAVEMENT
SUBGRADE REQUIREMENTS.
N/A
PREPARE PER SITE DESIGN ENGINEER'S PLANS.
PAVED INSTALLATIONS MAY HAVE STRINGENT
MATERIAL AND PREPARATION REQUIREMENTS.
C
INITIAL FILL: FILL MATERIAL FOR LAYER 'C'
STARTS FROM THE TOP OF THE EMBEDMENT
STONE ('B' LAYER) TO 18" (450 mm) ABOVE THE
TOP OF THE CHAMBER. NOTE THAT PAVEMENT
SUBBASE MAY BE A PART OF THE 'C' LAYER.
GRANULAR WELL-GRADED SOIL/AGGREGATE MIXTURES, <35%
FINES OR PROCESSED AGGREGATE.
MOST PAVEMENT SUBBASE MATERIALS CAN BE USED IN LIEU
OF THIS LAYER.
AASHTO M145¹
A-1, A-2-4, A-3
OR
AASHTO M43¹
3, 357, 4, 467, 5, 56, 57, 6, 67, 68, 7, 78, 8, 89,
9, 10
BEGIN COMPACTIONS AFTER 12" (300 mm) OF
MATERIAL OVER THE CHAMBERS IS REACHED.
COMPACT ADDITIONAL LAYERS IN 6" (150 mm) MAX
LIFTS TO A MIN. 95% PROCTOR DENSITY FOR
WELL GRADED MATERIAL AND 95% RELATIVE
DENSITY FOR PROCESSED AGGREGATE
MATERIALS. ROLLER GROSS VEHICLE WEIGHT
NOT TO EXCEED 12,000 lbs (53 kN). DYNAMIC
FORCE NOT TO EXCEED 20,000 lbs (89 kN).
B
EMBEDMENT STONE: FILL SURROUNDING THE
CHAMBERS FROM THE FOUNDATION STONE ('A'
LAYER) TO THE 'C' LAYER ABOVE.
CLEAN, CRUSHED, ANGULAR STONE AASHTO M43¹
3, 357, 4, 467, 5, 56, 57 NO COMPACTION REQUIRED.
A
FOUNDATION STONE: FILL BELOW CHAMBERS
FROM THE SUBGRADE UP TO THE FOOT (BOTTOM)
OF THE CHAMBER.
CLEAN, CRUSHED, ANGULAR STONE AASHTO M43¹
3, 357, 4, 467, 5, 56, 57
PLATE COMPACT OR ROLL TO ACHIEVE A FLAT
SURFACE. ² ³
18"
(450 mm) MIN*
8'
(2.4 m)
MAX
SUBGRADE SOILS
(SEE NOTE 4)
PAVEMENT LAYER (DESIGNED
BY SITE DESIGN ENGINEER)
SC-740
END CAP
6" (150 mm) MIN
D
C
B
A
PERIMETER STONE
(SEE NOTE 6)
EXCAVATION WALL
(CAN BE SLOPED OR VERTICAL)
12" (300 mm) MIN
ADS GEOSYNTHETICS 601T NON-WOVEN GEOTEXTILE ALL
AROUND CLEAN, CRUSHED, ANGULAR STONE IN A & B LAYERS
12" (300 mm) TYP51" (1295 mm)6"
(150 mm) MIN
30"
(760 mm)
DEPTH OF STONE TO BE DETERMINED
BY SITE DESIGN ENGINEER 6" (150 mm) MIN
*TO BOTTOM OF FLEXIBLE PAVEMENT. FOR UNPAVED
INSTALLATIONS WHERE RUTTING FROM VEHICLES MAY OCCUR,
INCREASE COVER TO 24" (600 mm).
SHEET
OFDATE:PROJECT #:DRAWN:CHECKED:THIS DRAWING HAS BEEN PREPARED BASED ON INFORMATION PROVIDED TO ADS UNDER THE DIRECTION OF THE SITE DESIGN ENGINEER OR OTHER PROJECT REPRESENTATIVE. THE SITE DESIGN ENGINEER SHALL REVIEW THIS DRAWING PRIOR TO CONSTRUCTION. IT IS THE ULTIMATERESPONSIBILITY OF THE SITE DESIGN ENGINEER TO ENSURE THAT THE PRODUCT(S) DEPICTED AND ALL ASSOCIATED DETAILS MEET ALL APPLICABLE LAWS, REGULATIONS, AND PROJECT REQUIREMENTS.4640 TRUEMAN BLVDHILLIARD, OH 430261-800-733-7473ADVANCED DRAINAGE SYSTEMS, INC.RREVDRWCHKDESCRIPTION01/19/16JLMJLMUPDATESC-740ISOLATOR ROW DETAILS11/18/14JLM1 1JLM70 INWOOD ROAD, SUITE 3 | ROCKY HILL | CT | 06067860-529-8188 |888-892-2694 | WWW.STORMTECH.COMDetention Retention Water QualityINSPECTION & MAINTENANCE
STEP 1)INSPECT ISOLATOR ROW FOR SEDIMENT
A.INSPECTION PORTS (IF PRESENT)
A.1.REMOVE/OPEN LID ON NYLOPLAST INLINE DRAIN
A.2.REMOVE AND CLEAN FLEXSTORM FILTER IF INSTALLED
A.3.USING A FLASHLIGHT AND STADIA ROD, MEASURE DEPTH OF SEDIMENT AND RECORD ON
MAINTENANCE LOG
A.4.LOWER A CAMERA INTO ISOLATOR ROW FOR VISUAL INSPECTION OF SEDIMENT LEVELS (OPTIONAL)
A.5.IF SEDIMENT IS AT, OR ABOVE, 3" (80 mm) PROCEED TO STEP 2. IF NOT, PROCEED TO STEP 3.
B.ALL ISOLATOR ROWS
B.1.REMOVE COVER FROM STRUCTURE AT UPSTREAM END OF ISOLATOR ROW
B.2.USING A FLASHLIGHT, INSPECT DOWN THE ISOLATOR ROW THROUGH OUTLET PIPE
i)MIRRORS ON POLES OR CAMERAS MAY BE USED TO AVOID A CONFINED SPACE ENTRY
ii)FOLLOW OSHA REGULATIONS FOR CONFINED SPACE ENTRY IF ENTERING MANHOLE
B.3.IF SEDIMENT IS AT, OR ABOVE, 3" (80 mm) PROCEED TO STEP 2. IF NOT, PROCEED TO STEP 3.
STEP 2)CLEAN OUT ISOLATOR ROW USING THE JETVAC PROCESS
A.A FIXED CULVERT CLEANING NOZZLE WITH REAR FACING SPREAD OF 45" (1.1 m) OR MORE IS PREFERRED
B.APPLY MULTIPLE PASSES OF JETVAC UNTIL BACKFLUSH WATER IS CLEAN
C.VACUUM STRUCTURE SUMP AS REQUIRED
STEP 3)REPLACE ALL COVERS, GRATES, FILTERS, AND LIDS; RECORD OBSERVATIONS AND ACTIONS.
STEP 4)INSPECT AND CLEAN BASINS AND MANHOLES UPSTREAM OF THE STORMTECH SYSTEM.
NOTES
1.INSPECT EVERY 6 MONTHS DURING THE FIRST YEAR OF OPERATION. ADJUST THE INSPECTION INTERVAL BASED ON
PREVIOUS OBSERVATIONS OF SEDIMENT ACCUMULATION AND HIGH WATER ELEVATIONS.
2.CONDUCT JETTING AND VACTORING ANNUALLY OR WHEN INSPECTION SHOWS THAT MAINTENANCE IS NECESSARY.
SUMP DEPTH TBD BY
SITE DESIGN ENGINEER
(24" [600 mm] MIN RECOMMENDED)
24" (600 mm) HDPE ACCESS PIPE REQUIRED
USE FACTORY PRE-FABRICATED END CAP
PART #: SC740EPE24B
TWO LAYERS OF ADS GEOSYNTHETICS 315WTK WOVEN
GEOTEXTILE BETWEEN FOUNDATION STONE AND CHAMBERS
5' (1.5 m) MIN WIDE CONTINUOUS FABRIC WITHOUT SEAMS
CATCH BASIN
OR
MANHOLE
COVER ENTIRE ISOLATOR ROW WITH ADS
GEOSYNTHETICS 601T NON-WOVEN GEOTEXTILE
8' (2.4 m) MIN WIDE
SC-740 CHAMBER
SC-740 END CAP
SC-740 ISOLATOR ROW DETAIL
NTS
OPTIONAL INSPECTION PORT
STORMTECH HIGHLY RECOMMENDS
FLEXSTORM PURE INSERTS IN ANY UPSTREAM
STRUCTURES WITH OPEN GRATES
SC-740 6" INSPECTION PORT DETAIL
NTS
SC-740 CHAMBER
FLEXSTORM CATCH IT
PART# 6212NYFX
WITH USE OF OPEN GRATE
12" (300 mm) NYLOPLAST INLINE
DRAIN BODY W/SOLID HINGED
COVER OR GRATE
PART# 2712AG6NIP
SOLID COVER: 1299CGC
GRATE: 1299CGS
6" (150 mm) INSERTA TEE
PART#6IPSSWST74IP
INSERTA TEE TO BE CENTERED
ON CORRUGATION CREST
6" (150 mm) DWV SCH40
PIPE (BY OTHERS)
18" (450 mm) MIN WIDTH
CONCRETE SLAB
8" (200 mm) MIN THICKNESS
PAVEMENT CONCRETE COLLAR NOT REQUIRED
FOR UNPAVED APPLICATIONS
CONCRETE COLLAR
PART #STUB A B C
SC740EPE06T / SC740EPE06TPC 6" (150 mm)10.9" (277 mm)18.5" (470 mm)---
SC740EPE06B / SC740EPE06BPC ---0.5" (13 mm)
SC740EPE08T /SC740EPE08TPC 8" (200 mm)12.2" (310 mm)16.5" (419 mm)---
SC740EPE08B / SC740EPE08BPC ---0.6" (15 mm)
SC740EPE10T / SC740EPE10TPC 10" (250 mm)13.4" (340 mm)14.5" (368 mm)---
SC740EPE10B / SC740EPE10BPC ---0.7" (18 mm)
SC740EPE12T / SC740EPE12TPC 12" (300 mm)14.7" (373 mm)12.5" (318 mm)---
SC740EPE12B / SC740EPE12BPC ---1.2" (30 mm)
SC740EPE15T / SC740EPE15TPC 15" (375 mm)18.4" (467 mm)9.0" (229 mm)---
SC740EPE15B / SC740EPE15BPC ---1.3" (33 mm)
SC740EPE18T / SC740EPE18TPC 18" (450 mm)19.7" (500 mm)5.0" (127 mm)---
SC740EPE18B / SC740EPE18BPC ---1.6" (41 mm)
SC740EPE24B*24" (600 mm)18.5" (470 mm)---0.1" (3 mm)
ALL STUBS, EXCEPT FOR THE SC740EPE24B ARE PLACED AT BOTTOM OF END CAP SUCH THAT THE OUTSIDE DIAMETER OF
THE STUB IS FLUSH WITH THE BOTTOM OF THE END CAP. FOR ADDITIONAL INFORMATION CONTACT STORMTECH AT
1-888-892-2694.
* FOR THE SC740EPE24B THE 24" (600 mm) STUB LIES BELOW THE BOTTOM OF THE END CAP APPROXIMATELY 1.75" (44 mm).
BACKFILL MATERIAL SHOULD BE REMOVED FROM BELOW THE N-12 STUB SO THAT THE FITTING SITS LEVEL.
NOTE: ALL DIMENSIONS ARE NOMINAL
NOMINAL CHAMBER SPECIFICATIONS
SIZE (W X H X INSTALLED LENGTH)51.0" X 30.0" X 85.4" (1295 mm X 762 mm X 2169 mm)
CHAMBER STORAGE 45.9 CUBIC FEET (1.30 m³)
MINIMUM INSTALLED STORAGE*74.9 CUBIC FEET (2.12 m³)
WEIGHT 75.0 lbs.(33.6 kg)
*ASSUMES 6" (152 mm) STONE ABOVE, BELOW, AND BETWEEN CHAMBERS
STUBS AT BOTTOM OF END CAP FOR PART NUMBERS ENDING WITH "B"
STUBS AT TOP OF END CAP FOR PART NUMBERS ENDING WITH "T"
SC-740 TECHNICAL SPECIFICATION
NTS
90.7" (2304 mm) ACTUAL LENGTH 85.4" (2169 mm)
INSTALLED LENGTH
OVERLAP NEXT CHAMBER HERE
(OVER SMALL CORRUGATION)
BUILD ROW IN THIS DIRECTION
START END
A A
C
B
51.0"
(1295 mm)
30.0"
(762 mm)
ACCEPTS 4" (100 mm) SCH 40 PVC PIPE FOR INSPECTION
PORT. FOR PIPE SIZES LARGER THAN 4" (100 mm) UP TO
10" (250 mm) USE INSERTA TEE CONNECTION CENTERED
ON A CHAMBER CREST CORRUGATION
45.9" (1166 mm)12.2"
(310 mm)
29.3"
(744 mm)
STORM CHAMBERS 2 STORM CHAMBERS 1
FG
STORM
CHAMBERS 1
V.P.
CABLE
F.O.HY DVAULT
ELEC
VAULT
ELECVAULT
ELEC
T
E
S
S
MH
S
SSS
S
S
T S
H2O
TRAFFIC
VAULTT SVAULT
ELEC
S
VAULT
ELEC
VAULT
ELEC
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
ELEC
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
S
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR HY DS
15" SS18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS
21" SS
21" SS21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS8" SS8" SS 8" SS 8" SSEEEEEEEEEETTTTTTTTGGGGGGGGGGGWW W W W W W W
12" W12" W12" W12" W12" W12" WEFOEEEEEEEEEGGGGGG30" W30" W30" W30" W30" W30" W30" W36" W36" W36" WFDC
FS UDE
E
E
E E UDU
D
U
D
U
D
U
DUDUD
UD
UD UD UD UD UDSSSSWWW
S
S
UDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDD
F.O.
D
S HY DMH
S
HY DMM
MH
ELEC
/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /XX30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W
XXXXXXXXXXXXSTSTSTSTSTSS
30" W
S
SSSSSSSSSSSSSS2
1
"
S
S
2
1
"
S
S
2
1
"
S
S
BBBBBBBBBBBBBB BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBXXBBBBBBBBBXXXXXE
E
E
E
G G G G G
G
G
G
G GTTGTE E
TTT
TVAULT
ELEC
VAULT
ELEC
E E E E
VAULT
ELECEEEEEE UDUDUDUD
E EGG
UD
EEEEE EE E
G
GGGGE E E E
EEEEE E E
G G G G G G
ETFDC
FDCFDC FDC
FDCFDCFDCFDC GGGGG G G GG G G
G G G G G
G GT NYLOPLAST
DO NOT POLLUTE DRAINS TO WATERWAYS
NYLOPLAST
DO NOT POLLUTE DRAINS TO WATERWAYS
VAULT
ELEC VAULTELECNYLOPLAST
DO NOT POLLUTE DRAINS TO WATERWAYSS SHIELDS ST.HOBBIT ST.WALLENBERG DR.FEMA 100-YR
HIGH RISK
FLOOD FRINGE
EXISTING 21" CLAY
SANITARY SEWER
EXISTING 18" CLAY
SANITARY SEWER
PROPOSED 8"
PVC WATER
EXISTING WATERLINEEXISTING 12" WATERLINE
EXISTING 12" WATERLINE
EXISTING 36" WATERLINE
EXISTING ELECTRIC
VAULT (TYP.)
EXISTING 8" PVC
SANITARY SEWER
EXISTING 15"
SANITARY SEWER
EXISTING
UNDERDRAIN
4' SANITARY
MANHOLE (TYP.)
PROPOSED FIRE
HYDRANT
PROPOSED FIRE
HYDRANT
PROPOSED FIRE
HYDRANT
PROPOSED FIRE
HYDRANT
33' WATERLINE EASEMENT
48' SANITARY SEWER EASEMENT
PROPOSED 2'
CONCRETE PAN
PROPOSED 2'
CONCRETE PAN
PROPOSED 2'
SIDEWALK
CHASE PROPOSED 1'
SIDEWALK CHASE
PROPOSED FIRE
HYDRANT
PROPOSED OUTLET
STRUCTURE
RAIN GARDEN
BIOMEDIA AREA
SPRING CREEK EXIST
ING
8
'
TRA
IL
EXISTI
N
G
S
P
R
I
N
G
C
R
E
E
K
T
R
A
I
L
NATURAL AREA
BUFFER
LOT 1
TRACT B
TRACT A
TRACT C
PROPOSED FIRE
HYDRANT CANAL IMPORTATIONCONNECT TO EXISTING
WATER LINE
CONNECT TO
EXISTING
WATER LINE
CONNECT TO EXISTING
WATER LINE
CONNECT TO EXISTING
WATER LINE
EXISTING FIRE HYDRANT
PROPOSED 8" PVC
WATER
EXISTING FIRE HYDRANT
CONNECT TO
EXISTING SANITARY
CONNECT TO
EXISTING SANITARY CONNECT TO
EXISTING SANITARY
EXISTING FIRE HYDRANT
REMOVE MANHOLE
CONNECT TO
EXISTING SANITARY
CONNECT TO
EXISTING SANITARY
EXISTING 26" STORM
EXISTING 30" STORM
EXISTING 18" CLAY
SANITARY SEWER
PROPOSED FIRE
HYDRANT
PROPOSED 2'
CONCRETE PAN
PROPOSED 2'
CONCRETE PAN
PROPOSED RETAINING
WALL (TYP.)
SANITARY LINE A
SEE SHEET C 610
SANITARY LINE D
SEE SHEET C 612
SANITARY LINE C
SEE SHEET C 612
STORM DRAIN 1
SEE SHEET C 620
PROPOSED 4'
SIDEWALK
CULVERT
FEMA 100-YR
FLOODWAY
CITY OF FORT COLLINS
100-YR FLOODWAY
FEMA 100-YR
HIGH RISK
FLOOD FRINGE
CITY OF FORT
COLLINS 100-YR
FLOODPLAIN
SANITARY LINE A3
SEE SHEET C 610
STORM DRAIN 4-4
SEE SHEET C 624
STORM DRAIN 4-4A
SEE SHEET C 624
STORM DRAIN 4
SEE SHEET C 624
STORM DRAIN 1-9
SEE SHEET C 622
STORM DRAIN 1-8
SEE SHEET C 622
STORM DRAIN 5
SEE SHEET C 625
STORM DRAIN 5
SEE SHEET C 625
STORM DRAIN 5-2
SEE SHEET C 625
PROPOSED 8"
PVC WATER
STORM DRAIN 2
SEE SHEET C 623
STORM DRAIN 3
SEE SHEET C 623
STORM DRAIN 6
SEE SHEET C 626
UNDERDRAIN
SEE SHEET C 626
PROPOSED 2'
CONCRETE PAN
CONNECT TO
EXISTING
WATER LINE
W STUART ST.
STORM DRAIN 1-5
SEE SHEET C 621
STORM DRAIN 1-6
SEE SHEET C 621
BUILDING 6
BUILDING 7
BUILDING 2
BUILDING 3
BUILDING 4
BUILDING 5
BUILDING 8BUILDING 18BUILDING 17BUILDING 16BUILDING 15BUILDING 14
BUILDING 13
BUILDING 12
BUILDING 11
BUILDING 10
BUILDING 9
BUILDING 1
PROPOSED 1'
SIDEWALK CHASE
PROPOSED STORM
CHAMBERS 2
SANITARY LINE B
SEE SHEET C 611
SANITARY LINE B3
SEE SHEET C 611
CULVERTS
SEE SHEET C 601-C 606
CULVERT
SEE SHEET C 601-C 606
CULVERTS
SEE SHEET U1-U4
CULVERT
SEE SHEET C 601-C 606
AREA DRAINS
SEE SHEET C 601-C 606
AREA DRAINS
SEE SHEET C 601-C 606
ROOF DRAINS
SEE SHEET C 607-C 608 ASHLAR DRW STU
A
R
T
S
T
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
C 600OVERALL UTILITY PLAN20CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
NORTH
( IN FEET )
1 inch = ft.
Feet06060
60
120 180
NOTES:
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY
OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN
THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE
CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES
AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES.
2.ALL WATER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITIES
SPECIFICATIONS , LATEST EDITION, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS
ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR
AS REQUIRED FOR ABNORMAL DEFLECTIONS.
3.ALL SEWER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY
SPECIFICATIONS SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST
EDITION.
4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE
NOT TO SCALE.
5.ALL WATERLINES SHALL HAVE A 4.5'-5.5' COVER FROM FINISHED GRADE TO TOP OF
PIPE.
6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS
SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND
ARE SUBJECT TO CHANGE IN THE FIELD.
7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
SANITARY SEWER MAINS, WATER MAINS & SERVICES.
8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN
THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO
BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS.
10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 1 4"
BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO
PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
11.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE CITYREGULATED, 100YEAR
CANAL IMPORTATION FLOODPLAIN/FLOODWAY AS WELL AS THE FEMA REGULATED
SPRING CREEK 100YEAR FLOODPLAIN/FLOODWAY. ANY DEVELOPMENT WITHIN THE
FLOODPLAIN MUST COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF CITY
MUNICIPAL CODE. THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM
THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE PERMIT FEES
PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES,
GRADING, FILL, DETENTION PONDS, BIKE PATHS, PARKING LOTS, UTILITIES,
LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE CITY OF FORT
COLLINS FLOODPLAIN LIMITS AS DELINEATED ON THE FINAL SUBDIVISION PLAT
12.ANY CONSTRUCTION ACTIVITIES, NONSTRUCTURAL DEVELOPMENT (BRIDGES,
SIDEWALKS, CULVERTS, VEGETATION, CURBCUTS, GRADING, ETC.) IN THE
REGULATORY FLOODWAY MUST BE PRECEDED BY A NORISE CERTIFICATION, WHICH
MUST BE PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF
COLORADO.
13.NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE FLOODWAY,
WHETHER TEMPORARY (DURING CONSTRUCTION) OR PERMANENT.
14. ANY PEDESTRIAN BRIDGES IN THE FLOODWAY THAT ARE NOT ABLE TO PASS THE 100
YEAR FLOW ARE REQUIRED TO BE “BREAKAWAY” AND TETHERED.
15. A BLANKET UTILITY EASEMENT EXISTS ACROSS THE PROJECT BOUNDARY WHERE
OTHER EASEMENTS ARE NOT PRESENT.
16. WATER AND FIRE SERVICES MUST HAVE A MINIMUM OF 4.5 FEET OF COVER AND A
MINIMUM OF 18" VERTICAL CLEARANCE FROM STORM SEWERS. ANY STORM SEWER
SHALLOWER THAN 5 FEET WILL REQUIRE THE WATER SERVICE TO BE INSTALLED
UNDER THE PROPOSED STORM SEWER WITH A MINIMUM OF 18 INCHES VERTICAL
SEPARATION.
EXISTING LOT LINE
EASEMENT LINE
SPROPOSED SEWER SERVICE
WPROPOSED WATER SERVICE
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
G
T
EXISTING STORM SEWER
EXISTING TELEPHONE
EXISTING GAS
EXISTING SANITARY SEWER
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPERTY BOUNDARY
EXISTING TELEPHONE PEDESTAL
PROPOSED STREET LIGHT
W
SS
PROPOSED LOT LINE
PROPOSED ROW
EXISTING ROW
EXISTING CABLE CTV
PROPOSED GAS PRIMARY G
PROPOSED GAS SECONDARY G
PROPOSED ELECTRIC PRIMARY E
EPROPOSED ELECTRIC SECONDARY
EEXISTING ELECTRIC
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
C 601 C 602
C 603 C 604
SSS
S
VAULT
ELEC
VAULT
ELEC
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
S
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
S
15" SS15" SS15" SS18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS
21" SS 21" SS 21" SS 21" SS
21" SS21" SS21" SS21" SS21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS8" SS8" SS 8" SS 8" SS 8" SS 8" SS
EEEEEEEEEEEEEEEEEEEEEEEEETTTTTTTTTTTTTTTTTTTTTTTGGGGGGGGGGGGGGGGGGGGGGWEEW W W W W W W W W W W W W W W W W W W W W W WW
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WW15" SSWWW/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /EXISTING 8" WATERLINE
EXISTING 18" CLAY
SANITARY SEWER
EXISTING 12" WATERLINE
EXISTING 12" WATERLINE
28.5' HALF ROW
EEEEEEEEEEEEE
E
EEEEEE E
E
SSS
SSWFFFEETTEEEEEEEEEEEEEEEEGE E
E
E
VAULT
ELEC
EEEEEEEEE E E E E E E E E
WE E E E E E E E E
EEEEEEEEE
E E E
G G G G G G G G G G G
G G G G G G G G
FDC
FDCFDC
FDCWGGGGGGG G G G G G G G GGGG
G G
TEG GE E E E E E E E E E E EEEEEEEVAULT
ELEC
EEGG G
G
GPROPOSED 8"
PVC WATER
EXISTING 15"
SANITARY SEWER
26'
FL-FL
26'
FL-FL
26'
FL-FL
26'
FL-FL
PROPOSED 2'
CONCRETE PAN
PROPOSED 2'
CONCRETE PAN
PROPOSED 2'
CONCRETE PAN
EXISTING 21" CLAY
SANITARY SEWER
PROPOSED 2'
SIDEWALK
CHASE
PROPOSED 1'
SIDEWALK CHASE
26' EMERGENCY ACCESS EASEMENT
26' EMERGENCY ACCESS EASEMENT
26' EMERGENCY ACCESS EASEMENT
26' EMERGENCY ACCESS EASEMENT
PROPOSED FIRE
HYDRANT
PROPOSED FIRE
HYDRANT
NEW MH CONNECTIONS TO
EXISTING SANITARY SHALL
BE MADE W/ PRECAST MH
PROPOSED 2'
CONCRETE PAN
SANITARY LINE A
SEE SHEET C 610
STORM DRAIN 1
SEE SHEET C 620
STORM DRAIN 1-9
SEE SHEET C 622
SANITARY LINE A3
SEE SHEET C 610
BUILDING 6 BUILDING 7
BUILDING 2
BUILDING 3
BUILDING 4
PROPOSED 1'
SIDEWALK CHASE
8" x 6" SWIVEL TEE
1 - 6" GV (E)
STA.=12+28.56
N: 1449222.36
E: 3113257.18
90° BEND w/ MRJ
STA.=12+58.72
N: 1449252.53
E: 3113257.19
8" x 6" SWIVEL TEE
1 - 6" GV (S)
1 - 8" GV (W)
STA.=14+38.64
N: 1449252.43
E: 3113437.12
8" x 6" TEE w/ MRJ
1 - 6" GV (E)
STA.=10+64.01
N: 1449057.82
E: 3113257.09
8" x 6" TEE w/ MRJ
1 - 6" GV (S)
STA.=15+22.10
N: 1449252.39
E: 3113520.57
PROPOSED 1'
SIDEWALK CHASE
PROPOSED 2'
SIDEWALK CHASE
6' SIDEWALK6' SIDEWALK
6' SIDEWALK6' SIDEWALK
4.5' SIDEWALK
S SHIELDS ST.HOBBIT ST.5' SIDEWALKEXISTING SIDEWALKLOT 19' SIDEWALKPROPOSED 2'
SIDEWALK CHASE
PROPOSED 1'
SIDEWALK CHASE
PROPOSED 1'
SIDEWALK CHASE
TEE 1-9.4
INV.=5011.12
FG=5015.49
12.56 LF
6" HDPE
@ 2.00%
INLET 1-9.4.1
INV.=5011.74
FG=5015.10
11.86 LF
8" HDPE
@ 2.00%
PIPE END B4
INV.=5018.27
FG=5018.27
PIPE END B3
FG=5018.23
PIPE END B2
INV.=5018.16
FG=5018.16
PIPE END B1
FG=5018.12
14.85 LF
12" HDPE
@ 2.15%
17.02 LF
12" HDPE
@ 0.50%
17.37 LF
12" HDPE
@ 0.50%
0.00 LF8" HDPE@ 0.00%
17.49 LF
8" HDPE
@ 0.50%
16.73 LF
8" HDPE
@ 0.50%
13.41 LF
8" HDPE
@ 0.50%
8.01 LF
8" HDPE
@ 0.50%
TEE 1-9.3
INV.=5010.98
FG=5015.21
INLET 1-9.3-1
INV.=5011.51
FG=5015.24
TEE 1-9.2
INV.=5010.89
FG=5015.08 13.78 LF
8" HDPE
@ 2.00%
INLET 1-9.2-1
INV.=5011.45
FG=5015.17
2.05 LF
8" HDPE
@ 0.50%
INLET 1-9.7-1
INV.=5011.61
FG=5015.33
TEE 1-9.7
INV.=5011.34
FG=5015.58
3.04 LF
8" HDPE
@ 0.50%
INLET 1-9.8-1
INV.=5011.61
FG=5015.33
TEE 1-9.8
INV.=5011.44
FG=5015.68
3.96 LF
8" HDPE
@ 0.50%
INLET 1-9.10-1
INV.=5011.48
FG=5015.21
TEE 1-9.10
INV.=5011.69
FG=5015.35
31.29 LF
8" HDPE
@ 0.50%
INLET 1-9.11
INV.=5011.85
FG=5014.97
PIPE END A11
INV.=5017.76
FG=5017.76
PIPE END A10
FG=5017.69
PIPE END A9
INV.=5017.41
FG=5017.41
INLET A8
INV.=5017.32
FG=5018.36
PIPE END A7
INV.=5013.49
FG=5017.24
PIPE END A6
INV.=5017.14
FG=5017.14
INLET A5
INV.=5017.06
FG=5018.37
PIPE END A4
FG=5016.97
PIPE END A3
INV.=5016.69
FG=5016.69
94.12 LF 8" HDPE @ 1.00%
TEE 1-9.9-1
INV.=5012.61
FG=5016.69
4.51 LF
8" HDPE
@ 2.00%
INLET 1-9.9-1.1
INV.=5012.70
FG=5016.32
26.04 LF
8" HDPE
@ 1.00%
4.51 LF
8" HDPE
@ 2.00%
INLET 1-9.9-2.1
INV.=5012.96
FG=5016.32
TEE 1-9.9-2
INV.=5012.87
FG=5016.61
65.17 LF 8" HDPE @ 1.00%
BEND 1-9.9-3
INV.=5013.52
FG=5016.93
8.69 LF
8" HDPE
@ 1.00%
INLET 1-9.9-4
INV.=5013.61
FG=5016.25
3.79 LF 8" HDPE @ 2.00%
INLET 1-12.1
INV.=5013.02
FG=5016.17
TEE 1-12
INV.=5012.82
FG=5016.88
8.01 LF
8" HDPE
@ 0.50%206.00 LF 8" PVCN00°01'50"E30.17 LF 8" PVCN00°01'50"E179.92 LF 8" PVC
S89°58'10"E
STORM DRAIN 1
SEE SHEET C 620
13.50 LF 6" PVC
N89°56'33"E 28.56 LF 6" PVCS00°00'00"E35.31 LF 6" PVC
N00°00'00"E
CONNECT TO EXISTING 8" WATER
8"x6" TAPPING SADDLE w/ 6" GV (S) & MTJ
N:1449454.28
E:3113341.26
WATER
LOWERING 1
SANITARY LINE A
SEE SHEET C 610
22.15 LF 6" PVC
N90°00'00"E
GARAGE 1
GARAGE 2
GARAGE 3
4.5' SIDEWALK
PROPOSED 1'
SIDEWALK CHASE
PROPOSED 1'
SIDEWALK CHASE
PROPOSED
CURB CUT
PROPOSED
CURB CUT
PROPOSED 1.5"
WATER SERVICE
AND METER
PROPOSED 6"
PROPOSED 6"
FIRE SERVICE
PROPOSED 6"
FIRE SERVICE
PROPOSED 6"
FIRE SERVICE
30.06 LF
8" HDPE
@ 2.00%
INLET 1-9.4-1
INV.=5012.01
FG=5015.98
PROPOSED 6"
SANITARY
SERVICE
PROPOSED 6"
SANITARY SERVICE
PROPOSED 6"
SANITARY SERVICE
PROPOSED 6"
SANITARY
SERVICE
PROPOSED 2'
CONCRETE PAN
PROPOSED
AC CONDENSER (TYP.)
PROPOSED
AC CONDENSER (TYP.)
NOTES:
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY
OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN
THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE
CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES
AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES.
2.ALL WATER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITIES
SPECIFICATIONS , LATEST EDITION, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS
ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR
AS REQUIRED FOR ABNORMAL DEFLECTIONS.
3.ALL SEWER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY
SPECIFICATIONS SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST
EDITION.
4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE
NOT TO SCALE.
5.ALL WATERLINES SHALL HAVE A 4.5'-5.5' COVER FROM FINISHED GRADE TO TOP OF
PIPE.
6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS
SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND
ARE SUBJECT TO CHANGE IN THE FIELD.
7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
SANITARY SEWER MAINS, WATER MAINS & SERVICES.
8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN
THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO
BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS.
10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 1 4"
BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO
PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
11.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE CITYREGULATED, 100YEAR
CANAL IMPORTATION FLOODPLAIN/FLOODWAY AS WELL AS THE FEMA REGULATED
SPRING CREEK 100YEAR FLOODPLAIN/FLOODWAY. ANY DEVELOPMENT WITHIN THE
FLOODPLAIN MUST COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF CITY
MUNICIPAL CODE. THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM
THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE PERMIT FEES
PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES,
GRADING, FILL, DETENTION PONDS, BIKE PATHS, PARKING LOTS, UTILITIES,
LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE CITY OF FORT
COLLINS FLOODPLAIN LIMITS AS DELINEATED ON THE FINAL SUBDIVISION PLAT
12.ANY CONSTRUCTION ACTIVITIES, NONSTRUCTURAL DEVELOPMENT (BRIDGES,
SIDEWALKS, CULVERTS, VEGETATION, CURBCUTS, GRADING, ETC.) IN THE
REGULATORY FLOODWAY MUST BE PRECEDED BY A NORISE CERTIFICATION, WHICH
MUST BE PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF
COLORADO.
13.NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE FLOODWAY,
WHETHER TEMPORARY (DURING CONSTRUCTION) OR PERMANENT.
14. ANY PEDESTRIAN BRIDGES IN THE FLOODWAY THAT ARE NOT ABLE TO PASS THE 100
YEAR FLOW ARE REQUIRED TO BE “BREAKAWAY” AND TETHERED.
15. A BLANKET UTILITY EASEMENT EXISTS ACROSS THE PROJECT BOUNDARY WHERE
OTHER EASEMENTS ARE NOT PRESENT.
16. WATER AND FIRE SERVICES MUST HAVE A MINIMUM OF 4.5 FEET OF COVER AND A
MINIMUM OF 18" VERTICAL CLEARANCE FROM STORM SEWERS. ANY STORM SEWER
SHALLOWER THAN 5 FEET WILL REQUIRE THE WATER SERVICE TO BE INSTALLED
UNDER THE PROPOSED STORM SEWER WITH A MINIMUM OF 18 INCHES VERTICAL
SEPARATION.
EXISTING LOT LINE
EASEMENT LINE
SPROPOSED SEWER SERVICE
WPROPOSED WATER SERVICE
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
G
T
EXISTING STORM SEWER
EXISTING TELEPHONE
EXISTING GAS
EXISTING SANITARY SEWER
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPERTY BOUNDARY
EXISTING TELEPHONE PEDESTAL
PROPOSED STREET LIGHT
W
SS
PROPOSED LOT LINE
PROPOSED ROW
EXISTING ROW
EXISTING CABLE CTV
PROPOSED GAS PRIMARY G
PROPOSED GAS SECONDARY G
PROPOSED ELECTRIC PRIMARY E
EPROPOSED ELECTRIC SECONDARY
EEXISTING ELECTRIC
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
C 601UTILITY PLAN21
( IN FEET )
0
1 INCH = 20 FEET
20 20 40 60
NORTH
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
SEE SHEET C 603 SEE SHEET C 602C 501 C 502
C 503 C 504
C 506 C 505C 505C 601 C 602
C 603 C 604
C 606 C 605C 605CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
XXXXXXXXXS
S
S
18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS
21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS
8" SS 8" SS 8" SSEEW W
XUDU
D
U
D
U
D
U
DUDUDUDUD
UD
UD
UD UD UD UD UD UD UD UD UD UD UD UD UD UD
UD
W W W W W W W W W
S
S
UDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDHY DMH
SSSWWF
FFEEEEEEEEEEEETTGGG
G GEEEE
E E
E EEEEEEES
WWWW
WFSS
VAULT
ELEC
EEEEEEEEUDUDUDUDUDUDUDWWGG G G G G
GGGGGGGGGGGGGWE E E E E
EEEEE18" SS 18" SS
WE E E E E E E E E
W
G G G G G
WSE
E E EEEE E E EEEEEEEE E E
EFDC
FDCFDCGGGEFFFFG
GGG GGG
SSSFSFFFSFFG G G G G G G G G GGG
SWNYLOPLAST
DO NOT POLLUTE DRAINS TO WATERWAYS
NYLOPLAST
DO NOT POLLUTE DRAINS TO WATERWAYS
EEEEEEEEEEVAULTELECE
EGEEEEEEEEEEEEEEEE
E
WPROPOSED SANITARY
SERVICE (TYP.)
PROPOSED SANITARY
SERVICE (TYP.)
26'
FL-FL
PROPOSED
RAIN GARDEN
PROPOSED
FIRE HYDRANT
26' EMERGENCY ACCESS EASEMENT
26' EMERGENCY ACCESS EASEMENT
RAIN GARDEN
BIOMEDIA AREA
EXISTING 8" PVC
WATER
INSTALL NEW MANHOLE
CONNECT TO EXISTING
SANITARY SEWER
EXISTING FH
CONNECT TO
EXISTING
WATERLINE
PROPOSED 2'
SIDEWALK CHASE
PROPOSED 2'
CONCRETE PAN w/
6" CURBS
NEW MH CONNECTIONS TO
EXISTING SANITARY SHALL
BE MADE W/ PRECAST MH
NEW MH CONNECTIONS TO
EXISTING SANITARY SHALL
BE MADE W/ PRECAST MH
SANITARY LINE D
SEE SHEET C 612
SANITARY LINE C
SEE SHEET C 612
STORM DRAIN 1
SEE SHEET C 620
PROPOSED
RETAINING WALL
(TYP.)
PROPOSED WATER SERVICE
w/ INTERNAL METER (TYP.)
PROPOSED WATER SERVICE
w/ INTERNAL METER (TYP.)
NATURAL AREA
BUFFER
STORM DRAIN 1-8
SEE SHEET C 622
UNDERDRAIN
SEE SHEET C 626
SANITARY LINE B
SEE SHEET C 611
SANITARY LINE B3
SEE SHEET C 611
BENCH TO BE
CHANNELIZED
FOR SERVICE
PROPOSED 2'
CONCRETE PAN w/
6" CURBS
UTILITY EASEMENT
EXCLUSION
BUILDING 4 BUILDING 5 BUILDING 8
BUILDING 18 BUILDING 17
BUILDING 16
BUILDING 15
BUILDING 14
BUILDING 13
BUILDING 12
BUILDING 11
BUILDING 10
BUILDING 9
PROPOSED
FOREBAY
PROPOSED 1'
SIDEWALK CHASE
PROPOSED 2'
SIDEWALK CHASE
PROPOSED 2'
CONCRETE PAN
STORM DRAIN 1-5
SEE SHEET C 621
STORM DRAIN 1-6
SEE SHEET C 621
90° BEND w/ MRJ
STA.=16+96.72
N: 1449252.30
E: 3113695.19
8" TEE w/ MRJ
2 - 8" GV (E, S)
STA.=17+41.42
N: 1449296.99
E: 3113695.22
8" x 6" SWIVEL TEE
1 - 6" GV (W)
STA.=18+18.53
N: 1449374.10
E: 3113695.27
8" TEE
1 - 8" GV (S)
STA.=18+96.24
N: 1449451.81
E: 3113695.30
90° BEND w/ MRJ
STA.=11+56.78
N: 1449296.91
E: 3113851.99
8" x 6" SWIVEL TEE
1 - 6" GV (W)
STA.=12+57.14
N: 1449196.54
E: 3113851.94
8" x 6" TEE w/ MRJ
1 - 6" GV (S)
STA.=15+22.10
N: 1449252.39
E: 3113520.57
8" x 6" TEE w/ MRJ
1 - 6" GV (S)
STA.=16+22.28
N: 1449252.34
E: 3113620.75
8" x 6" TEE w/ MRJ
1 - 6" GV (S)
STA.=10+77.16
N: 1449296.95
E: 3113772.37
8" x 4" TEE w/ MRJ
1 - 4" GV (E)
STA.=11+93.58
N: 1449260.10
E: 3113851.97
8" x 4" TEE w/ MRJ
1 - 4" GV (E)
STA.=12+23.20
N: 1449230.48
E: 3113851.96
8" x 4" TEE w/ MRJ
1 - 4" GV (E)
STA.=12+66.75
N: 1449186.93
E: 3113851.94
8" x 4" TEE w/ MRJ
1 - 4" GV (E)
STA.=13+10.14
N: 1449143.54
E: 3113851.91
8" x 6" TEE w/ MRJ
1 - 6" GV (E)
STA.=13+77.20
N: 1449076.48
E: 3113851.88
PROPOSED 1'
SIDEWALK CHASE
PROPOSED
1' SIDEWALK
CHASE
PROPOSED 1'
SIDEWALK CHASE
PROPOSED 2'
SIDEWALK CHASE
PROPOSED 1'
SIDEWALK CHASE
PROPOSED 2'
SIDEWALK CHASE
PROPOSED 1'
SIDEWALK CHASE9' SIDEWALK4.5' SIDEWALK
9' SIDEWALK9' SIDEWALK9' SIDEWALK7' SIDEWALK6' SIDEWALK4' SIDEWALK
4' SIDEWALK
6' SIDEWALK 4' SIDEWALKLOT 1
TRACT A
LOT 1 10' SIDEWALK6' SIDEWALK 4' SIDEWALKPROPOSED 2'
SIDEWALK CHASE
PROPOSED 1'
SIDEWALK CHASE
INLET 1-6.2-4
INV.=5010.60
FG=5012.61
BEND 1-6.2-3 w CO
INV.=5010.46
FG=5014.30
BEND 1-6.2-2
INV.=5010.39
FG=5014.51
BEND 1-6.2-1 w CO
INV.=5010.34
FG=5014.50
43.50 LF
8" HDPE
@ 0.40%
PROPOSED 1'
SIDEWALK CHASE
258.08 LF 8" PVC
S89°58'10"E
44.69 LF 8" PVC
N00°01'50"E 77.11 LF 8" PVCN00°02'10"E77.71 LF 8" PVC
N00°01'30"E
156.78 LF 8" PVC
S89°58'10"E
100.37 LF 8" PVC
S00°01'50"W
203.20 LF 8" PVCS00°01'50"WPROPOSED
FIRE HYDRANT
28.56 LF 6" PVCS00°00'00"EWATER
LOWERING 3
17.51 LF 6" PVC
S00°01'50"W
54.49 LF 1.5" PVC
N90°00'00"E
13.94 LF 1" PVC
S00°20'53"W
13.78 LF 1" PVC
S00°20'53"W
18.66 LF 1" PVC
S00°20'53"W
8" x 1.5" TEE w/ TB
1 - 1.5" GV (E)
STA.=18+85.21
N: 1449440.78
E: 3113695.29
WATER
LOWERING 4
29.74 LF 1" PVC
S89°58'10"E
32.27 LF 1" PVC
S89°58'10"E
31.91 LF 1" PVC
S89°58'10"E
WATER
LOWERING 5
29.74 LF 1" PVC
S89°58'10"E
37.54 LF 1" PVC
S89°58'10"E
SEE NOTE #16
SEE NOTE #16
SEE NOTE #16
SEE NOTE #16
SEE NOTE #16
PIPE END C1
FG=5009.05
INLET C2
INV.=5009.21
FG=5012.16
11.78 LF
8" HDPE
@ 1.00%
GARAGE 4
GARAGE 5
STA. 11+66.85
1.5" x 1" TEE w/ MRJ
N:1449445.41
E:3113859.96
STA. 11+17.67
1.5" x 1" TEE w/ MRJ
N:1449445.71
E:3113810.78
STA. 10+89.61
1.5" x 1" TEE w/ MRJ
N:1449445.88
E:3113782.72
STA. 12+12.13
45.00° BEND w/ MRJ
N:1449445.13
E:3113905.24
STA. 12+23.44
45.00° BEND w/ MRJ
N:1449437.09
E:3113913.19
STA. 10+54.49
45.00° BEND w/ MRJ
N:1449440.78
E:3113749.79
FIRE SERVICE LINE
SEE PROFILE - SHEET C 606
STA. 10+61.93
45.00° BEND w/ MRJ
N:1449446.04
E:3113755.05
PROPOSED 1'
SIDEWALK CHASE
WATER
LOWERING 2
10.63 LF 8" HDPE @ 1.00%
BEND C3
INV.=5009.31
FG=5013.50
30.02 LF
8" HDPE
@ 1.00%
TEE C4
INV.=5009.61
FG=5014.25
2.52 LF
8" HDPE
@ 0.50%
INLET C4-1
INV.=5009.63
FG=5013.71
2.69 LF
8" HDPE
@ 0.50%
INLET C5
INV.=5009.63
FG=5013.74
PROPOSED 6"
FIRE SERVICE
PROPOSED 1.5"
WATER SERVICE
AND METER
PROPOSED 1.5"
WATER SERVICE
AND METER
PROPOSED 6"
FIRE SERVICE
PROPOSED 1"
FIRE SERVICE
PROPOSED 1"
FIRE SERVICE
PROPOSED 1"
FIRE SERVICE
PROPOSED 1"
FIRE SERVICE
PROPOSED 6"
FIRE SERVICE
PROPOSED 1.5"
WATER SERVICE
AND METER
PROPOSED 6"
FIRE SERVICE
PROPOSED 1.5"
WATER SERVICE
AND METER
PROPOSED 6"
SANITARY
SERVICE
PROPOSED 6"
SANITARY
SERVICE
PROPOSED 6"
SANITARY
SERVICE
PROPOSED
TRENCH DRAIN
59.16 LF
4" HDPE
@ 4.00%BLDG 5 RD 1
INV.=5013.14
FG=5016.00
58.65 LF
4" HDPE
@ 3.00%
BLDG 5 RD 2
INV.=5013.16
FG=5016.29
22.84 LF
4" HDPE
@ 3.00%BLDG 8 RD 1
INV.=5011.46
FG=5015.54BLDG 8 RD TEE 1
INV.=5009.86
FG=5014.52
BLDG 5 RD TEE 1
INV.=5010.28
FG=5014.24
BLDG 5 RD TEE 2
INV.=5010.48
FG=5014.14
27.69 LF
4" HDPE
@ 2.00%
BLDG 8 RD 2
INV.=5012.01
FG=5015.54
33.44 LF8" HDPE@ 0.50%RD 1-5 BEND 1
INV.=5010.71
FG=5014.45
26.54 LF8" HDPE@ 0.50%RD 1-5 TEE 2 w CO
INV.=5010.84
FG=5014.58
25.13 LF
6" HDPE
@ 2.00%
RD 1-5 TEE 2.1 w CO
INV.=5011.43
FG=5015.08
21.53 LF
4" HDPE
@ 2.00%21.19 LF4" HDPE@ 2.00%RD 1-5 BEND 2.2 w CO
INV.=5011.94
FG=5015.03
20.45 LF
4" HDPE
@ 2.00%
BLDG 5 RD 3
INV.=5012.34
FG=5016.00
BLDG 5 RD 4
INV.=5011.94
FG=5016.30
52.69 LF
4" HDPE
@ 1.50%
RD 1-5 BEND 4 w CO
INV.=5011.26
FG=5014.3314.56 LF4" HDPE@ 0.50%39.34 LF
4" HDPE
@ 2.00%14.56 LF4" HDPE@ 0.50%RD 1-5 TEE 3
INV.=5011.10
FG=5014.41 35.07 LF6" HDPE@ 0.50%BLDG 8 RD 3
INV.=5011.97
FG=5015.54
PROPOSED
1' SIDEWALK
CHASE
7.44 LF 1.5" PVC
N45°00'00"E
27.67 LF 1.5" PVC
S89°39'07"E
28.06 LF 1.5" PVC
S89°39'07"E
49.18 LF 1.5" PVC
S89°39'07"E
45.28 LF 1" PVC
S89°39'07"E 11.31 LF 1" PVC
S44°39'07"E
7.24 LF 1" PVC
S00°20'53"W
18.66 LF 1" PVC
S00°20'53"W
ASHLAR DRPROPOSED
AC CONDENSER (TYP.)
PROPOSED
AC CONDENSER (TYP.)
PROPOSED
AC CONDENSER
(TYP.)
PROPOSED
AC CONDENSER (TYP.)
NOTES:
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY
OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN
THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE
CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES
AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES.
2.ALL WATER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITIES
SPECIFICATIONS , LATEST EDITION, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS
ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR
AS REQUIRED FOR ABNORMAL DEFLECTIONS.
3.ALL SEWER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY
SPECIFICATIONS SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST
EDITION.
4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE
NOT TO SCALE.
5.ALL WATERLINES SHALL HAVE A 4.5'-5.5' COVER FROM FINISHED GRADE TO TOP OF
PIPE.
6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS
SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND
ARE SUBJECT TO CHANGE IN THE FIELD.
7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
SANITARY SEWER MAINS, WATER MAINS & SERVICES.
8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN
THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO
BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS.
10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 1 4"
BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO
PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
11.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE CITYREGULATED, 100YEAR
CANAL IMPORTATION FLOODPLAIN/FLOODWAY AS WELL AS THE FEMA REGULATED
SPRING CREEK 100YEAR FLOODPLAIN/FLOODWAY. ANY DEVELOPMENT WITHIN THE
FLOODPLAIN MUST COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF CITY
MUNICIPAL CODE. THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM
THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE PERMIT FEES
PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES,
GRADING, FILL, DETENTION PONDS, BIKE PATHS, PARKING LOTS, UTILITIES,
LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE CITY OF FORT
COLLINS FLOODPLAIN LIMITS AS DELINEATED ON THE FINAL SUBDIVISION PLAT
12.ANY CONSTRUCTION ACTIVITIES, NONSTRUCTURAL DEVELOPMENT (BRIDGES,
SIDEWALKS, CULVERTS, VEGETATION, CURBCUTS, GRADING, ETC.) IN THE
REGULATORY FLOODWAY MUST BE PRECEDED BY A NORISE CERTIFICATION, WHICH
MUST BE PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF
COLORADO.
13.NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE FLOODWAY,
WHETHER TEMPORARY (DURING CONSTRUCTION) OR PERMANENT.
14. ANY PEDESTRIAN BRIDGES IN THE FLOODWAY THAT ARE NOT ABLE TO PASS THE 100
YEAR FLOW ARE REQUIRED TO BE “BREAKAWAY” AND TETHERED.
15. A BLANKET UTILITY EASEMENT EXISTS ACROSS THE PROJECT BOUNDARY WHERE
OTHER EASEMENTS ARE NOT PRESENT.
16. WATER AND FIRE SERVICES MUST HAVE A MINIMUM OF 4.5 FEET OF COVER AND A
MINIMUM OF 18" VERTICAL CLEARANCE FROM STORM SEWERS. ANY STORM SEWER
SHALLOWER THAN 5 FEET WILL REQUIRE THE WATER SERVICE TO BE INSTALLED
UNDER THE PROPOSED STORM SEWER WITH A MINIMUM OF 18 INCHES VERTICAL
SEPARATION.
EXISTING LOT LINE
EASEMENT LINE
SPROPOSED SEWER SERVICE
WPROPOSED WATER SERVICE
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
G
T
EXISTING STORM SEWER
EXISTING TELEPHONE
EXISTING GAS
EXISTING SANITARY SEWER
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPERTY BOUNDARY
EXISTING TELEPHONE PEDESTAL
PROPOSED STREET LIGHT
W
SS
PROPOSED LOT LINE
PROPOSED ROW
EXISTING ROW
EXISTING CABLE CTV
PROPOSED GAS PRIMARY G
PROPOSED GAS SECONDARY G
PROPOSED ELECTRIC PRIMARY E
EPROPOSED ELECTRIC SECONDARY
EEXISTING ELECTRIC
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
C 602UTILITY PLAN22
( IN FEET )
0
1 INCH = 20 FEET
20 20 40 60
NORTH
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
SEE SHEET C 604SEE SHEET C 601C 601 C 602
C 603 C 604
C 606 C 605C 605SEE SHEET C 605CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
T S
H2O
TRAFFIC
VAULTT SVAULT
ELEC
CONTROL
IRR
CONTROL
IRR
ELEC
CONTROL
IRR
CONTROL
IRR EEEEEEEETTTTGGGGGGGGGGGG12" W12" WEEEEEEEEEEEEEEEEEEEEEEEEGGGGGGGGGGG30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W36" W36" W36" W36" W36" W36" W36" W36" W36" WD
/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W
STSTSTSTSTSTSTSTSTS
SSSSSSSSSSSSSSSSSSSSSSSSEXISTING 36" WATERLINE EWFE
E
E
E
E
E
E
G G G G G G G G G G G G G G
G
G
G
G
G
G
T
TVAULT
ELEC
EEEE E E E E E E E E E E E
WW
UD
UD
UD
UD
EEEEEEEEE E E EEEEEEEEEEEEEEEEE
SSEEEEFDCW
G
GGGGGGG G G G G G G G G G G G G G GEE
EG G
G
GGGGGGIRIRNYLOPLAST
DO NOT POLLUTE DRAINS TO WATERWAYS
FPROPOSED 8"
PVC WATER
PROPOSED 1.5" WATER
SERVICE AND METER
31'
FL-FL
26'
FL-FL
60'
FL-FL
EXISTING 30" WATERLINE
PROPOSED 2'
CONCRETE CHASE
31' EMERGENCY ACCESS EASEMENT
EXISTING 26"
STORM DRAIN
EXISTING 30"
STORM DRAIN
33' WATERLINE
EASEMENT
PROPOSED
FIRE HYDRANT
PROPOSED FIRE
HYDRANT
PROPOSED 4'
SIDEWALK CULVERT
NATURAL
AREA BUFFER
EXISTING 30"
WATERLINE
FEMA 100-YR
HIGH RISK
FLOOD FRINGE
PROPOSED
POND OUTLET
STRUCTURE
PROPOSED 1.5"
IRRIGATION METER
AND SERVICE
PROPOSED 2'
CONCRETE PAN
STORM DRAIN 4
SEE SHEET C 624
STORM DRAIN 4-4
SEE SHEET C 624
STORM DRAIN 4-4A
SEE SHEET C 624
STORM DRAIN 4
SEE SHEET C 624
STORM DRAIN 5
SEE SHEET C 625
UTILIT
Y
E
A
S
E
M
E
N
T
EXCL
U
SI
O
N
BUILDING 3
BUILDING 1
50' PUBLIC ACCESS &
TRAIL EASEMENT
PROPOSED 2'
SIDEWALK CHASE
22.5° BEND w/ MRJ
STA.=13+37.79
N: 1448815.90
E: 3113435.84
8" x 6" SWIVEL TEE
1 - 8" GV (E)
1 - 6" GV (S)
STA.=14+32.31
N: 1448815.96
E: 3113341.32
8" x 6" TEE w/ MRJ
1 - 6" GV (W)
STA.=10+44.01
N: 1449037.82
E: 3113257.08
8" x 6" SWIVEL TEE
1 - 6" GV (W)
STA.=10+22.56
N: 1449016.36
E: 3113257.07
8" x 6" TEE w/ MRJ
1 - 6" GV (N)
STA.=13+56.07
N: 1448815.91
E: 3113417.56
PROPOSED 2'
SIDEWALK CHASE
6' SIDEWALK 6' SIDEWALK
9' SIDEWALK
8' SIDEWALK
S SHIELDS ST.EXIS
TI
N
G
S
P
RI
N
G
C
R
E
E
K
T
R
AI
L
SPRI
N
G
C
R
E
E
K
TRACT C
EXISTING SIDEWALKTRACT B 9' SIDEWALK9' SIDEWALK
10' SIDEWALK
W STUART ST.
19.14 LF
12" HDPE
@ 0.50%
14.85 LF
12" HDPE
@ 2.15%
INLET A2
INV.=5016.37
FG=5017.76
PIPE END A1
FG=5016.27
TEE 4-4.1
INV.=5013.22
FG=5016.30
42.93 LF
8" HDPE
@ 0.50%
INLET 4-4.1-1
INV.=5013.43
FG=5016.02
23.65 LF
8" HDPE
@ 0.50%
INLET 4-4.1-2
INV.=5013.55
FG=5016.26 PROPOSED 1'
SIDEWALK CHASE
PROPOSED 2'
SIDEWALK CHASE
INLET 4-4.6-1
INV.=5014.04
FG=5016.92
4.08 LF 6" HDPE @ 0.50%
246.22
L
F
8
"
P
V
C
S68°4
0'
2
9
"
W
22.56 LF 8" PVC
N00°01'50"E
68.57 LF 6" PVC
N90°00'00"E
CONNECT TO EXISTING 30" WATER
30"x8" TAPPING SADDLE w/ 8" GV (N) & MRJ
STA.=10+00.00
N: 1448993.81
E: 3113257.06
1.95 LF 6" PVC
S89°58'15"E
FEMA 100-YR
FLOODWAY
PROPOSED
STORM CHAMBERS 2
CITY IRRIGATION TAP
FOR FUTURE USE
WATER
LOWERING 7
WATER
LOWERING 6
PROPOSED 6"
FIRE SERVICE
PROPOSED 1.5"
WATER SERVICE
AND METER
PROPOSED 8"
SANITARY
SERVICE
PROPOSED 6"
SANITARY
SERVICE
PROPOSED
POND DEPTH
GAUGE
BENCH TO BE
CHANNELIZED
FOR SERVICE
PROPOSED 2"
WATER
SERVICE
& METER
ROOF DRAIN
SEE SHEET C 607-C 608
ROOF DRAIN
SEE SHEET C 607-C 608
ROOF DRAIN
SEE SHEET C 607-C 608
SERVICE CONNECTION
N: 1448816.06
E: 3113136.90
W STUART ST
LOT 1
PROPOSED 1"
WATER SERVICE
& METER
STORM DRAIN 6
SEE SHEET C 626
PROPOSED
TRENCH DRAIN
PROPOSED
AC CONDENSER (TYP.)103.41 LF 6" PVCS00°01'45"WNOTES:
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY
OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN
THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE
CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES
AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES.
2.ALL WATER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITIES
SPECIFICATIONS, LATEST EDITION, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS
ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR
AS REQUIRED FOR ABNORMAL DEFLECTIONS.
3.ALL SEWER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY
SPECIFICATIONS SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST
EDITION.
4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE
NOT TO SCALE.
5.ALL WATERLINES SHALL HAVE A 4.5'-5.5' COVER FROM FINISHED GRADE TO TOP OF
PIPE.
6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS
SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND
ARE SUBJECT TO CHANGE IN THE FIELD.
7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
SANITARY SEWER MAINS, WATER MAINS & SERVICES.
8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN
THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO
BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS.
10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 14"
BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO
PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
11.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE CITYREGULATED, 100YEAR
CANAL IMPORTATION FLOODPLAIN/FLOODWAY AS WELL AS THE FEMA REGULATED
SPRING CREEK 100YEAR FLOODPLAIN/FLOODWAY. ANY DEVELOPMENT WITHIN THE
FLOODPLAIN MUST COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF CITY
MUNICIPAL CODE. THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM
THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE PERMIT FEES
PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES,
GRADING, FILL, DETENTION PONDS, BIKE PATHS, PARKING LOTS, UTILITIES,
LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE CITY OF FORT
COLLINS FLOODPLAIN LIMITS AS DELINEATED ON THE FINAL SUBDIVISION PLAT
12.ANY CONSTRUCTION ACTIVITIES, NONSTRUCTURAL DEVELOPMENT (BRIDGES,
SIDEWALKS, CULVERTS, VEGETATION, CURBCUTS, GRADING, ETC.) IN THE
REGULATORY FLOODWAY MUST BE PRECEDED BY A NORISE CERTIFICATION, WHICH
MUST BE PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF
COLORADO.
13.NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE FLOODWAY,
WHETHER TEMPORARY (DURING CONSTRUCTION) OR PERMANENT.
14. ANY PEDESTRIAN BRIDGES IN THE FLOODWAY THAT ARE NOT ABLE TO PASS THE 100
YEAR FLOW ARE REQUIRED TO BE “BREAKAWAY” AND TETHERED.
15. A BLANKET UTILITY EASEMENT EXISTS ACROSS THE PROJECT BOUNDARY WHERE
OTHER EASEMENTS ARE NOT PRESENT.
16. WATER AND FIRE SERVICES MUST HAVE A MINIMUM OF 4.5 FEET OF COVER AND A
MINIMUM OF 18" VERTICAL CLEARANCE FROM STORM SEWERS. ANY STORM SEWER
SHALLOWER THAN 5 FEET WILL REQUIRE THE WATER SERVICE TO BE INSTALLED
UNDER THE PROPOSED STORM SEWER WITH A MINIMUM OF 18 INCHES VERTICAL
SEPARATION.
EXISTING LOT LINE
EASEMENT LINE
SPROPOSED SEWER SERVICE
WPROPOSED WATER SERVICE
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
G
T
EXISTING STORM SEWER
EXISTING TELEPHONE
EXISTING GAS
EXISTING SANITARY SEWER
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPERTY BOUNDARY
EXISTING TELEPHONE PEDESTAL
PROPOSED STREET LIGHT
W
SS
PROPOSED LOT LINE
PROPOSED ROW
EXISTING ROW
EXISTING CABLE CTV
PROPOSED GAS PRIMARY G
PROPOSED GAS SECONDARY G
PROPOSED ELECTRIC PRIMARY E
EPROPOSED ELECTRIC SECONDARY
EEXISTING ELECTRIC
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
C 603UTILITY PLAN23
( IN FEET )
0
1 INCH = 20 FEET
20 20 40 60
NORTH
KEYMAP
CABLEF.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24"
SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEEEEEEEEEE EEEEEEEEEEEEEEEEEEEETTTTTTTTTTTTTTTTTTTTTTTTTTTTTTGW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEE EEEEEEEEEEEEEEEEEEEGGGGGGGGGGG GGGGGG GGGGX
X
X
X
X
X
XX
X
X
X
XX
X
X
XXXX
X
XX
X
XXX
X
X
X
XXXX
X
X
X
X
XX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUD
UDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUD
MH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTST ST STSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSEE SHEET C 601
SEE SHEET C 604C 601 C 602
C 603 C 604
C 606 C 605C 605SEE SHEET C 606
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBXBBBBBBXELEC
XXXX30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W
MCCOY JOHN H/SHERRY P
1900 S SHIELDS ST
E
E
E
E
E
E
E
E
E
G
G
G
G
G
G
G
G
G
G GGGT
EEWVAULT
ELEC
EEUD UD UD
E E E E E E EG G G G G G G G
UD EEEE E E EE E E E E E E E GGGEEEEETFG G G GG G G G G G
E
E E EE
E E E
E EEGGGGGGGGGGE E EEEE E EEG G G
26'
FL-FL
26'
FL-FL
PROPOSED
FIRE HYDRANT
26' EMERGENCY ACCESS EASEMENT
33' WATERLINE
EASEMENT 33' WATERLINE EASEMENT
NATURAL AREA
BUFFER
NATURAL
AREA BUFFER
PROPOSED 8"
PVC WATER
FEMA 100-YR
HIGH RISK
FLOOD FRINGE
EXISTING 30"
WATERLINE
PROPOSED 2'
CONCRETE PAN
PROPOSED
RETAINING WALL
(TYP.)
PROPOSED WATER SERVICE
w/ INTERNAL METER (TYP.)
PROPOSED STORM
CHAMBERS 1
PROPOSED
STORM CHAMBERS 2
FEMA 100-YR
FLOODWAY
STORM DRAIN 2
SEE SHEET C 623
STORM DRAIN 4
UTILITY EASEMENT
EXCLUSION
UTILITY EASEMENT
EXCLUSION
BUILDING 9
CONNECT TO EXISTING 8" WATER
30"x8" TAPPING SADDLE w/ 8" GV (N) & MRJ
STA.=14+60.34
N: 1448993.34
E: 3113851.83
CONNECT TO EXISTING 30" WATER
30"x8" TAPPING SADDLE w/ 8" GV (S) & MRJ
STA.=10+00.00
N: 1448993.18
E: 3113684.25
22.5° BEND w/ MRJ
STA.=10+45.07
N: 1448948.07
E: 3113683.89
8" x 6" SWIVEL TEE
1 - 6" GV (NW)
STA.=10+53.12
N: 1448940.65
E: 3113680.64
45° BEND w/ MRJ
STA.=10+91.57
N: 1448905.44
E: 3113665.20
8" x 4" TEE w/ MRJ
1 - 4" GV (E)
STA.=14+12.83
N: 1449040.85
E: 3113851.86
PROPOSED
TRENCH DRAIN
10' SID
E
W
A
L
K
9' SIDEWALK
10' SIDEWALK
6' SID
E
W
A
L
K
SPRING CREEK
EXISTING
S
P
R
I
N
G
C
R
E
E
K
T
R
A
I
L
TRACT B
LOT 1
LOT 1 10' SIDEWALKPROPOSED 2'
SIDEWALK CHASE
STORM DRAIN 2A
SEE SHEET C 623
41.87 LF 8" PVC
S00°26'56"W
4.86 LF 8" PVC
S23°40'29"W
38.44 LF 8" PVCS23°40'29"W246.22
L
F
8
"
P
V
C
S68°4
0'
2
9
"
W
37.54 LF 1" PVC
S89°58'10"E
PROPOSED
POND OUTLET
STRUCTURE
STORM DRAIN 5
SEE SHEET C 625
6' SIDE
W
A
L
K
50' PUBLIC ACCESS &
TRAIL EASEMENT
STORM CHAMBERS 2
PROPOSED 1"
FIRE SERVICE
52.69 LF
4" HDPE
@ 1.50%
BLDG 5 RD 5
INV.=5012.05
FG=5015.43
W STU
A
R
T
S
T
PROPOSED
AC CONDENSER (TYP.)
NOTES:
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY
OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN
THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE
CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES
AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES.
2.ALL WATER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITIES
SPECIFICATIONS , LATEST EDITION, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS
ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR
AS REQUIRED FOR ABNORMAL DEFLECTIONS.
3.ALL SEWER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY
SPECIFICATIONS SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST
EDITION.
4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE
NOT TO SCALE.
5.ALL WATERLINES SHALL HAVE A 4.5'-5.5' COVER FROM FINISHED GRADE TO TOP OF
PIPE.
6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS
SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND
ARE SUBJECT TO CHANGE IN THE FIELD.
7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
SANITARY SEWER MAINS, WATER MAINS & SERVICES.
8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN
THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO
BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS.
10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 1 4"
BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO
PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
11.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE CITYREGULATED, 100YEAR
CANAL IMPORTATION FLOODPLAIN/FLOODWAY AS WELL AS THE FEMA REGULATED
SPRING CREEK 100YEAR FLOODPLAIN/FLOODWAY. ANY DEVELOPMENT WITHIN THE
FLOODPLAIN MUST COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF CITY
MUNICIPAL CODE. THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM
THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE PERMIT FEES
PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES,
GRADING, FILL, DETENTION PONDS, BIKE PATHS, PARKING LOTS, UTILITIES,
LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE CITY OF FORT
COLLINS FLOODPLAIN LIMITS AS DELINEATED ON THE FINAL SUBDIVISION PLAT
12.ANY CONSTRUCTION ACTIVITIES, NONSTRUCTURAL DEVELOPMENT (BRIDGES,
SIDEWALKS, CULVERTS, VEGETATION, CURBCUTS, GRADING, ETC.) IN THE
REGULATORY FLOODWAY MUST BE PRECEDED BY A NORISE CERTIFICATION, WHICH
MUST BE PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF
COLORADO.
13.NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE FLOODWAY,
WHETHER TEMPORARY (DURING CONSTRUCTION) OR PERMANENT.
14. ANY PEDESTRIAN BRIDGES IN THE FLOODWAY THAT ARE NOT ABLE TO PASS THE 100
YEAR FLOW ARE REQUIRED TO BE “BREAKAWAY” AND TETHERED.
15. A BLANKET UTILITY EASEMENT EXISTS ACROSS THE PROJECT BOUNDARY WHERE
OTHER EASEMENTS ARE NOT PRESENT.
16. WATER AND FIRE SERVICES MUST HAVE A MINIMUM OF 4.5 FEET OF COVER AND A
MINIMUM OF 18" VERTICAL CLEARANCE FROM STORM SEWERS. ANY STORM SEWER
SHALLOWER THAN 5 FEET WILL REQUIRE THE WATER SERVICE TO BE INSTALLED
UNDER THE PROPOSED STORM SEWER WITH A MINIMUM OF 18 INCHES VERTICAL
SEPARATION.
EXISTING LOT LINE
EASEMENT LINE
SPROPOSED SEWER SERVICE
WPROPOSED WATER SERVICE
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
G
T
EXISTING STORM SEWER
EXISTING TELEPHONE
EXISTING GAS
EXISTING SANITARY SEWER
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPERTY BOUNDARY
EXISTING TELEPHONE PEDESTAL
PROPOSED STREET LIGHT
W
SS
PROPOSED LOT LINE
PROPOSED ROW
EXISTING ROW
EXISTING CABLE CTV
PROPOSED GAS PRIMARY G
PROPOSED GAS SECONDARY G
PROPOSED ELECTRIC PRIMARY E
EPROPOSED ELECTRIC SECONDARY
EEXISTING ELECTRIC
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
C 604UTILITY PLAN24
( IN FEET )
0
1 INCH = 20 FEET
20 20 40 60
NORTH
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
SEE SHEET C 602
SEE SHEET C 603C 601 C 602
C 603 C 604
C 606 C 605C 605SEE SHEET C 605CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
XXXXXXXXXXXXXXXXXXXXMH
S
S18" SS 18" SS 18" SS 18" SS
18" SS21" SS 21" SS 21" SS
UD
S
UDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDS
HY DMM
MHXXXXXXXXXXX XXXXXXXXXXXSSSS SS
2
1
"
S
SUDUDUDUDUDUD
UDUDPROPOSED
RAIN GARDEN
RAIN GARDEN
BIOMEDIA AREA
FEMA 100-YR
HIGH RISK
FLOOD FRINGE
CITY OF FORT
COLLINS 100-YR
FLOODPLAIN
EXISTING FH
CITY OF FORT COLLINS
100-YR FLOODWAY
UNDERDRAIN
SEE SHEET C 626
UTILITY EASEMENT
EXCLUSION
PROPOSED
FOREBAY WALLENBERG DR.EXISTING 8'
TRA
IL
TRACT A
CANAL
IMPORTAT
ION
PIPE END C1
FG=5009.05
11.78 LF
8" HDPE
@ 1.00%BXBBBBBBBBBUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDXXXXX30" W 30" W 30" W
XXXXXXXXXXXXXXXXXXXST30" W 30" W 30" W
WINNE GRANT R/JOHNELLE S
1821 WALLENBERG DR
ERIKSEN CHRISTOPHER M
1825 WALLENBERG DR
2
1
"
S
S
2
1
"
S
S
2
1
"
S
S
2
1
"
S
S
2
1
"
S
SUDUD
EXISTING 6"
CMP STORM
DRAIN
EXISTING
UNDERDRAIN
FEMA 100-YR
HIGH RISK
FLOOD FRINGE
CITY OF FORT
COLLINS 100-YR
FLOODPLAIN
CITY OF FORT COLLINS
100-YR FLOODWAY
STORM DRAIN 3
SEE SHEET C 623
STORM DRAIN 2
SEE SHEET C 623
STORM DRAIN 5
SEE SHEET C 625
STORM DRAIN 5-2
SEE SHEET C 625
UTILITY EASEMENT
EXCLUSION
CANAL IMPORTATIONTRACT A12' ACCESS TRAILSTORM DRAIN 2A
SEE SHEET C 623
EMERGENCY
OVERFLOW WEIR
PROPOSED
POND OUTLET
STRUCTURE
GARAGE 6
EXI
S
T
I
N
G
S
P
R
I
N
G
C
R
E
E
K
T
R
A
I
L
50' PUBLIC ACCESS &
TRAIL EASEMENT
PROPOSED
POND DEPTH
GAUGE
NOTES:
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY
OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN
THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE
CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES
AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES.
2.ALL WATER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITIES
SPECIFICATIONS , LATEST EDITION, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS
ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR
AS REQUIRED FOR ABNORMAL DEFLECTIONS.
3.ALL SEWER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY
SPECIFICATIONS SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST
EDITION.
4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE
NOT TO SCALE.
5.ALL WATERLINES SHALL HAVE A 4.5'-5.5' COVER FROM FINISHED GRADE TO TOP OF
PIPE.
6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS
SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND
ARE SUBJECT TO CHANGE IN THE FIELD.
7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
SANITARY SEWER MAINS, WATER MAINS & SERVICES.
8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN
THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO
BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS.
10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 1 4"
BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO
PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
11.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE CITYREGULATED, 100YEAR
CANAL IMPORTATION FLOODPLAIN/FLOODWAY AS WELL AS THE FEMA REGULATED
SPRING CREEK 100YEAR FLOODPLAIN/FLOODWAY. ANY DEVELOPMENT WITHIN THE
FLOODPLAIN MUST COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF CITY
MUNICIPAL CODE. THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM
THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE PERMIT FEES
PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES,
GRADING, FILL, DETENTION PONDS, BIKE PATHS, PARKING LOTS, UTILITIES,
LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE CITY OF FORT
COLLINS FLOODPLAIN LIMITS AS DELINEATED ON THE FINAL SUBDIVISION PLAT
12.ANY CONSTRUCTION ACTIVITIES, NONSTRUCTURAL DEVELOPMENT (BRIDGES,
SIDEWALKS, CULVERTS, VEGETATION, CURBCUTS, GRADING, ETC.) IN THE
REGULATORY FLOODWAY MUST BE PRECEDED BY A NORISE CERTIFICATION, WHICH
MUST BE PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF
COLORADO.
13.NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE FLOODWAY,
WHETHER TEMPORARY (DURING CONSTRUCTION) OR PERMANENT.
14. ANY PEDESTRIAN BRIDGES IN THE FLOODWAY THAT ARE NOT ABLE TO PASS THE 100
YEAR FLOW ARE REQUIRED TO BE “BREAKAWAY” AND TETHERED.
15. A BLANKET UTILITY EASEMENT EXISTS ACROSS THE PROJECT BOUNDARY WHERE
OTHER EASEMENTS ARE NOT PRESENT.
16. WATER AND FIRE SERVICES MUST HAVE A MINIMUM OF 4.5 FEET OF COVER AND A
MINIMUM OF 18" VERTICAL CLEARANCE FROM STORM SEWERS. ANY STORM SEWER
SHALLOWER THAN 5 FEET WILL REQUIRE THE WATER SERVICE TO BE INSTALLED
UNDER THE PROPOSED STORM SEWER WITH A MINIMUM OF 18 INCHES VERTICAL
SEPARATION.
EXISTING LOT LINE
EASEMENT LINE
SPROPOSED SEWER SERVICE
WPROPOSED WATER SERVICE
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
G
T
EXISTING STORM SEWER
EXISTING TELEPHONE
EXISTING GAS
EXISTING SANITARY SEWER
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPERTY BOUNDARY
EXISTING TELEPHONE PEDESTAL
PROPOSED STREET LIGHT
W
SS
PROPOSED LOT LINE
PROPOSED ROW
EXISTING ROW
EXISTING CABLE CTV
PROPOSED GAS PRIMARY G
PROPOSED GAS SECONDARY G
PROPOSED ELECTRIC PRIMARY E
EPROPOSED ELECTRIC SECONDARY
EEXISTING ELECTRIC
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
C 605UTILITY PLAN25
( IN FEET )
0
1 INCH = 20 FEET
20 20 40 60
NORTH
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
SEE THIS SHEET RIGHTSEE SHEET C 602SEE SHEET C 604SEE THIS SHEET LEFT
C 601 C 602
C 603 C 604
C 606 C 605C 605CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
CABLE
F.O.
VAULT
ELECVAULT
ELEC
T
E EEEFOFOFOFOEEEEEEEEGGGGGGGGG30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WF.O.
D
S / / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /XSTSTSTSTSTSTSTSTSTSTSTHILL POND CONDOMINIUMS
SSSSSSSSSSSSSSSSSSSSEEEEEXISTING 18" CLAY
SANITARY SEWER
FEMA 100-YR
FLOODWAY
4995
5000
5005
5010
5015
5020
5025
4995
5000
5005
5010
5015
5020
5025
9+75 10+00 11+00 12+00 12+50
PROPOSED
GROUND
EXISTING
GROUND
5005.995006.075006.145006.225006.305006.385006.455006.535006.615007.911.5" PVC
STA. 10+00.08" x 1.5" TEET.O.P.=5005.99STA. 12+20.011.25° VERTICAL BENDT.O.P.=5006.67STA. 12+30.7BLDG 15 SERVICET.O.P.=5009.33STA. 12+23.441" x 1" TEET.O.P.=5007.52STA. 12+12.131" x 1" TEET.O.P.=5006.64STA. 11+66.851.5" x 1" x 1" TEET.O.P.=5006.50STA. 11+17.671.5" x 1" TEET.O.P.=5006.35STA. 10+89.611.5" x 1" TEET.O.P.=5006.27STA. 10+61.9345° BENDT.O.P.=5006.18STA. 10+54.4945° BENDT.O.P.=5006.161" PVC
PROPOSED
GROUND
PROPOSED
TOP OF PIPE
NOTES:
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY
OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN
THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE
CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES
AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES.
2.ALL WATER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITIES
SPECIFICATIONS , LATEST EDITION, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS
ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR
AS REQUIRED FOR ABNORMAL DEFLECTIONS.
3.ALL SEWER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY
SPECIFICATIONS SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST
EDITION.
4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE
NOT TO SCALE.
5.ALL WATERLINES SHALL HAVE A 4.5'-5.5' COVER FROM FINISHED GRADE TO TOP OF
PIPE.
6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS
SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND
ARE SUBJECT TO CHANGE IN THE FIELD.
7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
SANITARY SEWER MAINS, WATER MAINS & SERVICES.
8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN
THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO
BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS.
10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 1 4"
BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO
PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
11.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE CITYREGULATED, 100YEAR
CANAL IMPORTATION FLOODPLAIN/FLOODWAY AS WELL AS THE FEMA REGULATED
SPRING CREEK 100YEAR FLOODPLAIN/FLOODWAY. ANY DEVELOPMENT WITHIN THE
FLOODPLAIN MUST COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF CITY
MUNICIPAL CODE. THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM
THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE PERMIT FEES
PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES,
GRADING, FILL, DETENTION PONDS, BIKE PATHS, PARKING LOTS, UTILITIES,
LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE CITY OF FORT
COLLINS FLOODPLAIN LIMITS AS DELINEATED ON THE FINAL SUBDIVISION PLAT
12.ANY CONSTRUCTION ACTIVITIES, NONSTRUCTURAL DEVELOPMENT (BRIDGES,
SIDEWALKS, CULVERTS, VEGETATION, CURBCUTS, GRADING, ETC.) IN THE
REGULATORY FLOODWAY MUST BE PRECEDED BY A NORISE CERTIFICATION, WHICH
MUST BE PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF
COLORADO.
13.NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE FLOODWAY,
WHETHER TEMPORARY (DURING CONSTRUCTION) OR PERMANENT.
14. ANY PEDESTRIAN BRIDGES IN THE FLOODWAY THAT ARE NOT ABLE TO PASS THE 100
YEAR FLOW ARE REQUIRED TO BE “BREAKAWAY” AND TETHERED.
15. A BLANKET UTILITY EASEMENT EXISTS ACROSS THE PROJECT BOUNDARY WHERE
OTHER EASEMENTS ARE NOT PRESENT.
16. WATER AND FIRE SERVICES MUST HAVE A MINIMUM OF 4.5 FEET OF COVER AND A
MINIMUM OF 18" VERTICAL CLEARANCE FROM STORM SEWERS. ANY STORM SEWER
SHALLOWER THAN 5 FEET WILL REQUIRE THE WATER SERVICE TO BE INSTALLED
UNDER THE PROPOSED STORM SEWER WITH A MINIMUM OF 18 INCHES VERTICAL
SEPARATION.
EXISTING LOT LINE
EASEMENT LINE
SPROPOSED SEWER SERVICE
WPROPOSED WATER SERVICE
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
G
T
EXISTING STORM SEWER
EXISTING TELEPHONE
EXISTING GAS
EXISTING SANITARY SEWER
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPERTY BOUNDARY
EXISTING TELEPHONE PEDESTAL
PROPOSED STREET LIGHT
W
SS
PROPOSED LOT LINE
PROPOSED ROW
EXISTING ROW
EXISTING CABLE CTV
PROPOSED GAS PRIMARY G
PROPOSED GAS SECONDARY G
PROPOSED ELECTRIC PRIMARY E
EPROPOSED ELECTRIC SECONDARY
EEXISTING ELECTRIC
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
C 606UTILITY PLAN26
( IN FEET )
0
1 INCH = 20 FEET
20 20 40 60
NORTH
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
SEE SHEET C 604
C 601 C 602
C 603 C 604
C 606 C 605C 605100 NORTHEAST DUPLEX FIRE SERVICE LINE
H2O
TRAFFIC
VAULTT SVAULT
ELEC
CONTROL
ELEC
CONTROL
IRR
CONTROL
IRR EEEEEETTTTGGGGGGGGGGGGGGGGGGG12" WEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEGGGGG30" W30" W30" W30" W30" W30" W30" W30" W36" W36" W36" W36" W36" W36" W36" W36" W36" W36" W36" W36" W36" W36" W36" W/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W
EXISTING 36" WATERLINE
G G G G G G G G G G G G G G G G G G
F
EEEE E E E E E E E E E E E E E E E E
WW
FDCGGGGGGGG G G G G G G G G
PROPOSED 8"
PVC WATER
FL-FL
60'
FL-FL
EXISTING 30" WATERLINE
PROPOSED FIRE HYDRANT
EXISTING 30"
WATERLINE
STORM DRAIN 4-4
SEE SHEET C 624
STORM DRAIN 6
SEE SHEET C 626
8" x 6" TEE w/ MRJ
1 - 6" GV (N)
STA.=15+30.23
N: 1448816.01
E: 3113243.40
6' SIDEWALK
LOT 1
9' SIDEWALK
TEE 4-4.1
INV.=5013.22
FG=5016.30
4.08 LF 6" HDPE @ 0.50%
22.56 LF 8" PVC
N00°01'50"E
CONNECT TO EXISTING 30" WATER
30"x8" TAPPING SADDLE w/ 8" GV (N) & MRJ
STA.=10+00.00
N: 1448993.81
E: 3113257.06
34.85 LF 6" PVC
S00°00'00"E
RD 6-2W BEND 5 w CO
INV.=5013.39
FG=5017.25
RD 6-2E BEND 6 w CO
INV.=5013.74
FG=5017.09
RD 6-2W BEND 12 w CO
INV.=5014.22
FG=5017.05
RD 6-2W TEE 7
INV.=5013.56
FG=5017.31
RD 6-2W TEE 11
INV.=5014.08
FG=5017.10
RD 6-2W TEE 9
INV.=5013.87
FG=5017.30
BLDG 1 RD 1
INV.=5014.25
FG=5017.27
RD 6-2W TEE 10
INV.=5014.01
FG=5017.21
RD 6-2W TEE 6
INV.=5013.42
FG=5017.27
RD 6-2W TEE 8
INV.=5013.80
FG=5017.41
BLDG 1 RD 2
INV.=5014.20
FG=5017.25
BLDG 1 RD 3
INV.=5014.13
FG=5017.25
BLDG 1 RD 4
INV.=5014.10
FG=5017.25
BLDG 1 RD 5
INV.=5014.03
FG=5017.29
RD 6-2E TEE 7
INV.=5013.79
FG=5017.19
BLDG 1 RD 6
INV.=5014.01
FG=5017.27
RD 6-2W TEE 4
INV.=5013.22
FG=5017.13
RD 6-2W TEE 3
INV.=5013.16
FG=5017.09
BLDG 1 RD 14
INV.=5013.95
FG=5017.27
RD 6-2E TEE 4
INV.=5013.55
FG=5017.10
BLDG 1 RD 15
INV.=5013.94
FG=5017.26
BLDG 1 RD 12
INV.=5013.92
FG=5017.26
RD 6-2E TEE 2
INV.=5013.12
FG=5017.08
BLDG 1 RD 17
INV.=5013.92
FG=5017.27
RD 6-2W TEE 2
INV.=5013.12
FG=5017.09
RD 6-2E TEE 5
INV.=5013.68
FG=5017.10
BLDG 1 RD 16
INV.=5013.91
FG=5017.26
RD 6-2W TEE 1
INV.=5013.11
FG=5017.07
BLDG 1 RD 13
INV.=5013.90
FG=5017.27
RD 6-2E BEND 1
INV.=5013.10
FG=5017.06
BLDG 1 RD 7
INV.=5013.86
FG=5017.27
RD 6-2E TEE 3
INV.=5013.44
FG=5017.12
BLDG 1 RD 8
INV.=5013.81
FG=5017.27
RD 6-2E WYE 2.1
INV.=5013.54
FG=5017.21
BLDG 1 RD 10
INV.=5013.76
FG=5017.26
BLDG 1 RD 9
INV.=5013.75
FG=5017.25
RD 6-2E BEND 3.1
INV.=5013.73
FG=5017.19
BLDG 1 RD 11
INV.=5013.69
FG=5017.26
13
.
1
4
L
F
12
"
H
D
P
E
@
0
.
5
0
%
2.39 LF
12" HDPE
@ 0.50%
8.59 LF
12" HDPE
@ 0.50%
10.50 LF
12" HDPE
@ 0.50%
34.14 LF
12" HDPE
@ 0.50%
6.82 LF 12" HDPE @ 0.50%27.28 LF 12" HDPE @ 0.50%15.67 LF 8" HDPE @ 0.50%
14.58 LF 8" HDPE @ 0.50%
10.75 LF 6" HDPE @ 0.50%
14.58 LF 6" HDPE @ 0.50%
10.83 LF 4" HDPE @ 0.50%
6.32 LF 4" HDPE @ 0.50%
6.25 LF 4" HDPE @ 0.50%
6.25 LF 4" HDPE @ 0.50%
6.25 LF 4" HDPE @ 1.00%
6.25 LF 4" HDPE @ 1.00%
6.25 LF 4" HDPE @ 2.00%
5.25 LF 4" HDPE @ 2.00%
6.44 LF
4" HDPE
@ 4.00%6.44 LF
4" HDPE
@ 4.00%
7.95 LF
4" HDPE
@ 4.00%
11.16 LF
12" HDPE
@ 0.50%
5.02 LF
12" HDPE
@ 0.50%
30.77 LF
8" HDPE
@ 0.50%
21.09 LF
8" HDPE
@ 0.50%
10.50 LF
6" HDPE
@ 0.50%
10.96 LF
6" HDPE
@ 0.50%10.58 LF
6" HDP
E
@ 0.50
%
8.10 LF 4" HDPE @ 0.50%
6.47 LF 4" HDPE @ 0.50%11.75 LF4" HDPE@ 2.00%11.75 LF
4" HDPE
@ 1.50%5.78 LF4" HDPE@ 2.00%8.44 LF 4" HDPE @ 2.00%
8.16 LF
6" HDPE
@ 2.00%
3.59 LF
4" HDPE
@ 2.00%15.15 LF
4" HDPE
@ 2.00%
WATER
LOWERING 6
PROPOSED 2"
WATER
SERVICE
& METER PROPOSED 1"
WATER SERVICE
& METER
BUILDING 1
SERVICE CONNECTION
N: 1448816.06
E: 3113136.90
97.91 LF 8" PVC
N89°58'11"W
106.50 LF 8" PVC
N89°58'11"W
W STUART ST
NOTES:
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY
OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN
THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE
CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES
AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES.
2.ALL WATER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITIES
SPECIFICATIONS , LATEST EDITION, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS
ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR
AS REQUIRED FOR ABNORMAL DEFLECTIONS.
3.ALL SEWER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY
SPECIFICATIONS SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST
EDITION.
4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE
NOT TO SCALE.
5.ALL WATERLINES SHALL HAVE A 4.5'-5.5' COVER FROM FINISHED GRADE TO TOP OF
PIPE.
6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS
SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND
ARE SUBJECT TO CHANGE IN THE FIELD.
7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
SANITARY SEWER MAINS, WATER MAINS & SERVICES.
8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN
THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO
BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS.
10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 1 4"
BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO
PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
11.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE CITYREGULATED, 100YEAR
CANAL IMPORTATION FLOODPLAIN/FLOODWAY AS WELL AS THE FEMA REGULATED
SPRING CREEK 100YEAR FLOODPLAIN/FLOODWAY. ANY DEVELOPMENT WITHIN THE
FLOODPLAIN MUST COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF CITY
MUNICIPAL CODE. THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM
THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE PERMIT FEES
PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES,
GRADING, FILL, DETENTION PONDS, BIKE PATHS, PARKING LOTS, UTILITIES,
LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE CITY OF FORT
COLLINS FLOODPLAIN LIMITS AS DELINEATED ON THE FINAL SUBDIVISION PLAT
12.ANY CONSTRUCTION ACTIVITIES, NONSTRUCTURAL DEVELOPMENT (BRIDGES,
SIDEWALKS, CULVERTS, VEGETATION, CURBCUTS, GRADING, ETC.) IN THE
REGULATORY FLOODWAY MUST BE PRECEDED BY A NORISE CERTIFICATION, WHICH
MUST BE PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF
COLORADO.
13.NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE FLOODWAY,
WHETHER TEMPORARY (DURING CONSTRUCTION) OR PERMANENT.
14. ANY PEDESTRIAN BRIDGES IN THE FLOODWAY THAT ARE NOT ABLE TO PASS THE 100
YEAR FLOW ARE REQUIRED TO BE “BREAKAWAY” AND TETHERED.
15. A BLANKET UTILITY EASEMENT EXISTS ACROSS THE PROJECT BOUNDARY WHERE
OTHER EASEMENTS ARE NOT PRESENT.
16. WATER AND FIRE SERVICES MUST HAVE A MINIMUM OF 4.5 FEET OF COVER AND A
MINIMUM OF 18" VERTICAL CLEARANCE FROM STORM SEWERS. ANY STORM SEWER
SHALLOWER THAN 5 FEET WILL REQUIRE THE WATER SERVICE TO BE INSTALLED
UNDER THE PROPOSED STORM SEWER WITH A MINIMUM OF 18 INCHES VERTICAL
SEPARATION.
EXISTING LOT LINE
EASEMENT LINE
SPROPOSED SEWER SERVICE
WPROPOSED WATER SERVICE
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
G
T
EXISTING STORM SEWER
EXISTING TELEPHONE
EXISTING GAS
EXISTING SANITARY SEWER
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPERTY BOUNDARY
EXISTING TELEPHONE PEDESTAL
PROPOSED STREET LIGHT
W
SS
PROPOSED LOT LINE
PROPOSED ROW
EXISTING ROW
EXISTING CABLE CTV
PROPOSED GAS PRIMARY G
PROPOSED GAS SECONDARY G
PROPOSED ELECTRIC PRIMARY E
EPROPOSED ELECTRIC SECONDARY
EEXISTING ELECTRIC
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
C607ROOF DRAIN PLANBUILDING 127
( IN FEET )
010 10 20 30
1 INCH = 10 FEET
NORTH
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R SEE SHEET C 608C 607
C 608
30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W
E
E
E
E
E
E
E
E
E
E
E
E
E
G G G G G G G G G G G G G G G
G
G
G
G
G
G
G
G
G
G
G
GEET
E E E E E E E E E E E E
UD
UD
UD
UD
UD
UD
UD
UD
UD
E E E E E E EEEE
SSEEEEEEEEG G G G G G G G G G G G G G G G G G G G G G G G G G G
EEEGGGGGGGNYLOPLAST
DO NOT POLLUTE DRAINS TO WATERWAYS
PROPOSED 8"
PVC WATER
31'
FL-FL
31' EMERGENCY ACCESS EASEMENT
33' WATERLINE
EASEMENT
STORM DRAIN 4-4
SEE SHEET C 624
STORM DRAIN 4-4A
SEE SHEET C 624
STORM DRAIN 4
SEE SHEET C 624
UTILIT
Y
E
A
S
E
M
E
N
T
EXCL
U
S
I
O
N
22.5° BEND w/ MRJ
STA.=13+37.79
N: 1448815.90
E: 3113435.84
8" x 6" SWIVEL TEE
1 - 8" GV (E)
1 - 6" GV (S)
STA.=14+32.31
N: 1448815.96
E: 3113341.32
6' SIDEWALK
9' SIDEWALK
LOT 1
9' SIDEWALK
TEE 4-4.1
INV.=5013.22
FG=5016.30
246.22
L
F
8
"
P
V
C
S68°4
0'
2
9
"
W
94.53 LF 8" PVC
N89°58'08"W
PROPOSED
STORM CHAMBERS 2
17.11 LF
4" HDPE
@ 2.50%
BLDG 1 RD 25
INV.=5013.86
FG=5017.27
18.11 LF
4" HDPE
@ 3.00%
BLDG 1 RD 24
INV.=5013.84
FG=5017.27
18.11 LF
4" HDPE
@ 3.00%
BLDG 1 RD 23
INV.=5013.93
FG=5017.27
11.53 LF
8" HDPE
@ 3.00%
8.02 LF 6" HDPE @ 3.00%
1.35 LF 8" HDPE @ 3.00%
TR DRAIN INLET 3.2
INV.=5012.77
FG=5016.77
TR DRAIN TEE 3.1
INV.=5012.73
FG=5017.17
TR DRAIN CONNECTION 3.1-1
INV.=5013.06
FG=5017.24
BLDG 1 RD 22
INV.=5013.76
FG=5017.27
17.11 LF
4" HDPE
@ 4.00%
45.97 LF 8" HDPE @ 0.50%14.44 LF4" HDPE@ 4.00%BLDG 1 RD 21
INV.=5013.23
FG=5017.27
RD 4-1 TEE 1
INV.=5012.49
FG=5016.93
10.50 LF
6" HDPE
@ 0.50%14.44 LF4" HDPE@ 4.00%BLDG 1 RD 20
INV.=5013.28
FG=5017.26
14.00 LF
6" HDPE
@ 0.50%
RD 4-1 TEE 3
INV.=5012.69
FG=5016.9614.44 LF4" HDPE@ 3.00%BLDG 1 RD 19
INV.=5013.21
FG=5017.26
9.56 LF
4" HDPE
@ 0.50%
RD 4-1 BEND 4 w CO
INV.=5012.82
FG=5016.97
2
0
.
1
8
L
F
4
"
H
D
P
E@
3
.
0
0%
RD 4-1 TEE 5
INV.=5013.43
FG=5017.27
RD 4-1 TEE 2
INV.=5012.62
FG=5016.95
RD 6-2E BEND 6 w CO
INV.=5013.74
FG=5017.09
RD 6-2E TEE 7
INV.=5013.79
FG=5017.19
BLDG 1 RD 14
INV.=5013.95
FG=5017.27
RD 6-2E TEE 4
INV.=5013.55
FG=5017.10
BLDG 1 RD 15
INV.=5013.94
FG=5017.26
BLDG 1 RD 17
INV.=5013.92
FG=5017.27
RD 6-2E TEE 5
INV.=5013.68
FG=5017.10
BLDG 1 RD 16
INV.=5013.91
FG=5017.26
RD 6-2E TEE 3
21.09 LF
8" HDPE
@ 0.50%
10.50 LF
6" HDPE
@ 0.50%
10.96 LF
6" HDPE
@ 0.50%10.58 LF6" HDP
E
@ 0.50
%
8.10 LF 4" HDPE @ 0.50%
6.47 LF 4" HDPE @ 0.50%11.75 LF4" HDPE@ 2.00%11.75 LF
4" HDPE
@ 1.50%
WATER
LOWERING 7
19.01 LF
6" HDPE
@ 2.00%
BLDG 1 CONNECTION
INV.=5012.97
FG=5017.27
PROPOSED 8"
SANITARY
SERVICE
PROPOSED 6"
SANITARY
SERVICE
PROPOSED
TRENCH DRAIN
BUILDING 1
97.91 LF 8" PVC
N89°58'11"W
W STUART ST
RD 4 TEE 2
INV.=5011.91
FG=5017.17
TR DRAIN TEE 3
INV.=5011.97
FG=5017.48
RD 4 TEE 4
INV.=5012.05
FG=5017.48
BLDG CONN. TEE 5
INV.=5012.09
FG=5017.48
RD 4 TEE 6
INV.=5012.13
FG=5017.48
RD 4 TEE 7
INV.=5012.26
FG=5017.43
RD 4 TEE 1
INV.=5011.84
FG=5016.79
NOTES:
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY
OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN
THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE
CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES
AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES.
2.ALL WATER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITIES
SPECIFICATIONS , LATEST EDITION, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS
ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR
AS REQUIRED FOR ABNORMAL DEFLECTIONS.
3.ALL SEWER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY
SPECIFICATIONS SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST
EDITION.
4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE
NOT TO SCALE.
5.ALL WATERLINES SHALL HAVE A 4.5'-5.5' COVER FROM FINISHED GRADE TO TOP OF
PIPE.
6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS
SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND
ARE SUBJECT TO CHANGE IN THE FIELD.
7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
SANITARY SEWER MAINS, WATER MAINS & SERVICES.
8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN
THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO
BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS.
10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 1 4"
BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO
PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
11.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE CITYREGULATED, 100YEAR
CANAL IMPORTATION FLOODPLAIN/FLOODWAY AS WELL AS THE FEMA REGULATED
SPRING CREEK 100YEAR FLOODPLAIN/FLOODWAY. ANY DEVELOPMENT WITHIN THE
FLOODPLAIN MUST COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF CITY
MUNICIPAL CODE. THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM
THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE PERMIT FEES
PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES,
GRADING, FILL, DETENTION PONDS, BIKE PATHS, PARKING LOTS, UTILITIES,
LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE CITY OF FORT
COLLINS FLOODPLAIN LIMITS AS DELINEATED ON THE FINAL SUBDIVISION PLAT
12.ANY CONSTRUCTION ACTIVITIES, NONSTRUCTURAL DEVELOPMENT (BRIDGES,
SIDEWALKS, CULVERTS, VEGETATION, CURBCUTS, GRADING, ETC.) IN THE
REGULATORY FLOODWAY MUST BE PRECEDED BY A NORISE CERTIFICATION, WHICH
MUST BE PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF
COLORADO.
13.NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE FLOODWAY,
WHETHER TEMPORARY (DURING CONSTRUCTION) OR PERMANENT.
14. ANY PEDESTRIAN BRIDGES IN THE FLOODWAY THAT ARE NOT ABLE TO PASS THE 100
YEAR FLOW ARE REQUIRED TO BE “BREAKAWAY” AND TETHERED.
15. A BLANKET UTILITY EASEMENT EXISTS ACROSS THE PROJECT BOUNDARY WHERE
OTHER EASEMENTS ARE NOT PRESENT.
16. WATER AND FIRE SERVICES MUST HAVE A MINIMUM OF 4.5 FEET OF COVER AND A
MINIMUM OF 18" VERTICAL CLEARANCE FROM STORM SEWERS. ANY STORM SEWER
SHALLOWER THAN 5 FEET WILL REQUIRE THE WATER SERVICE TO BE INSTALLED
UNDER THE PROPOSED STORM SEWER WITH A MINIMUM OF 18 INCHES VERTICAL
SEPARATION.
EXISTING LOT LINE
EASEMENT LINE
SPROPOSED SEWER SERVICE
WPROPOSED WATER SERVICE
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
G
T
EXISTING STORM SEWER
EXISTING TELEPHONE
EXISTING GAS
EXISTING SANITARY SEWER
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPERTY BOUNDARY
EXISTING TELEPHONE PEDESTAL
PROPOSED STREET LIGHT
W
SS
PROPOSED LOT LINE
PROPOSED ROW
EXISTING ROW
EXISTING CABLE CTV
PROPOSED GAS PRIMARY G
PROPOSED GAS SECONDARY G
PROPOSED ELECTRIC PRIMARY E
EPROPOSED ELECTRIC SECONDARY
EEXISTING ELECTRIC
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
C608ROOF DRAIN PLANBUILDING 128
( IN FEET )
010 10 20 30
1 INCH = 10 FEET
NORTH
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
RSEE SHEET C 607C 607
C 608
SSST SH2OTRAFFICVAULTT SVAULTELECSVAULTELECVAULTELECCONTROLIRRCONTROLIRRCONTROLIRRELECCONTROLIRRCONTROLIRRCONTROLIRRCONTROLIRRCONTROLIRRSCONTROLIRRCONTROLIRRCONTROLIRRCONTROLIRRS15" SS 18" SS18" SS18" SS18" SS18" SS18" SS21" SS21" SS 21" SS21" SS21" SS21" SS21" SS8" SSEEEEEEEEEEEETTTTTTTTTTGGGGGGGGGGGGGWWWWWWWW12" W12" W12" W12" W12" W12" W12" WEEEEEEEG30" W30" W36" W 36" W
36" WD/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /30" W30" W30" W30" W30" W30" WSSSSSEEEEEEESSSWWFF
FEGGGGGGFTTEEEEE TTEVAULTELECEEEEEEEEEWWEEEE EEEGGGGGGSSEFDCFDCFDCFDCWGGGGGGGGGGGGEEEEEEEVAULTELECGIRIRNYLOPLASTDO NOT POLLUTE DRAINS TO WATERWAYSS SHIELDS STREET
SSMH A1
STA 10+00.00
N: 1449316.39
E: 3113247.23
166.84 LF 8" PVC @ 0.50%
SSMH A3
STA 11+94.79
N: 1449121.61
E: 3113247.13
158.39 LF 8" PVC @ 0.50%
SSMH A4
STA 13+53.18
N: 1448963.21
E: 3113247.04
EXISTING 12"
WATERHOBBIT STREETPROPOSED
FIRE HYDRANT
EXISTING 18"
SANITARY SEWER
EXISTING 21"
SANITARY SEWER
EXISTING 8"
WATER LINE
EXISTING 30"
WATER LINE
PROPOSED
FIRE HYDRANT
CONNECT TO
EXISTING SANITARY
SEWER LINE w/
PRECAST MH 6' SIDEWALK6' SIDEWALK6' SIDEWALK9' SIDEWALK6' SIDEWALK9' SIDEWALKPROPOSED 4'
CONCRETE PAN
PROPOSED 4'
CONCRETE PAN
PROPOSED 8"
PVC WATER
PROPOSED 4'
SIDEWALK CULVERT
SANITARY LINE A2
SEE THIS SHEET - RIGHT
STORM DRAIN 4
SEE SHEET C 624
STORM DRAIN 4-4B
SEE SHEET C 624
STORM DRAIN 1
SEE SHEET C 620
STORM DRAIN 4-4A
SEE SHEET C 624
PROPOSED
FIRE HYDRANT
PROPOSED
FIRE HYDRANT
STORM DRAIN 6
SEE SHEET C 626
131.04 LF 8" PVC @ 0.50%
SSMH A8
STA 14+84.22
N: 1448962.65
E: 3113378.08
BUILDING
6
BUILDING
7
BUILDING
3
BUILDING
2
27.95 LF 8" PVC @ 0.50%
SSERV A2
STA 11+66.84
N: 1449149.55
E: 3113247.14
BLDG 2 SSERV
INV. OUT=5009.66 (E)
32.06 LF 6" @ 2.00%
32.15 LF 8" PVC @ 0.50%
BLDG 1 SSERV 2
INV. OUT=5011.18 (N)
BLDG 1 SSERV 3
INV. OUT=5011.52 (NW)
49.67 LF 6" PVC @ 1.00%
BLDG 6 SSERV
INV. OUT=5012.50 (S)
37.22 LF
6" PVC
@ 1.00%
BUILDING
1 W STUART ST4995
5000
5005
5010
5015
5020
5025
5030
5035
4995
5000
5005
5010
5015
5020
5025
5030
5035
9+50 10+00 11+00 12+00 13+00 14+00 15+00 15+50SSMH A1STA 10+00.00RIM 5017.3±INV. IN 5006.52 (W)INV. IN 5008.01 (S)INV. IN 5012.13 (N)INV. OUT 5006.51 (E)SSMH A3STA 11+94.79RIM 5016.6±INV. IN 5009.19 (S)INV. IN 5009.19 (E)INV. OUT 5008.99 (N)158.39 LF 8" PVC @ 0.50%SSMH A4STA 13+53.18RIM 5016.7±INV. IN 5010.17 (E)INV. OUT 5009.97 (N)PROPOSED
GROUND
EXISTING
GROUND SSMH A8STA 11+30.95RIM 5016.0±INV. IN 5011.02 (S)INV. IN 5011.02 (SE)INV. OUT 5010.82 (W)SERVICE A2STA 10+00.01RIM 5009.6±INV. IN 5009.02 (W)INV. IN 5008.85 (S)INV. OUT 5008.85 (N)SVC.166.84 LF 8" PVC @ 0.50%
27.95 LF 8" PVC @ 0.50%
131.04 LF 8" PVC @ 0.50%
12" HDPE STORM
STA.=13+41.80
INV.=5013.41
6" PVC WATER
STA.=13+00.02
TOP=5012.20
30" WATER
STA.=13+22.58
TOP=5007.49
6" PVC WATER
STA.=12+76.98
TOP=5012.32
18" MIN.ALL CROSSINGS SHALL BE
WRAPPED 10 FT EACH
SIDE PER DETAIL 205
FLOW
FILL CROSSING
S
S
VAULT
ELEC
VAULT
ELEC
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
ELEC
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
S
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS21" SS21" SS 21" SS 21" SS 21" SS 21" SS 21" SS
EEEEEEEEEETTTTTTTTGGGGGGGGG12" W12" W12" W12" W12" W12" W/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" WEEEEEEEESSSSSWFFFT EEEEEETT
EE
EEE E E
WEEEEEEEE
E E
EFDC
FDCFDC FDC
FDCW
GGGG G G G GG
GTEGE E E E E
VAULT
ELEC
G
GGIRNYLOPLAST
DO NOT POLLUTE DRAINS TO WATERWAYS
6' SIDEWALK6' SIDEWALK6' SIDEWALK
9' SIDEWALK
SSMH A3
STA 10+00.00
N: 1449121.61
E: 3113247.13
82.95 LF 8" PVC @ 0.50%
SSMH A2-2
STA 11+92.91
N: 1449121.61
E: 3113440.04SANITARY LINE A
SEE THIS SHEET - LEFT
STORM DRAIN 4-4B
SEE SHEET C 624
STORM DRAIN 4-4A
SEE SHEET C 624
STORM DRAIN 1-6
SEE SHEET C 622
STORM DRAIN 1-7
SEE SHEET C 622
PROPOSED 4'
CONCRETE PAN
EXISTING 18"
SANITARY SEWER
STORM DRAIN 1
SEE SHEET C 620
PROPOSED
ELECTRIC
EXISTING 21"
SANITARY SEWER
PROPOSED
FIRE HYDRANT
PROPOSED
FIRE HYDRANT
PROPOSED
FIRE HYDRANT
EXISTING 30"
WATER LINE
PROPOSED
GAS
BUILDING
6
BUILDING
2
BUILDING
3
BUILDING
7
BUILDING
4
109.97 LF 8" PVC @ 0.50%
SSERV A2-1
STA 10+82.95
N: 1449121.61
E: 3113330.07
BLDG 3 SSERV
INV. OUT=5009.90 (N)
29.78 LF 6" PVC @ 1.00%
BLDG 4 SSERV
INV. OUT=5010.73 (W)
37.60 LF 6" @ 1.00%
4995
5000
5005
5010
5015
5020
5025
5030
5035
4995
5000
5005
5010
5015
5020
5025
5030
5035
9+50 10+00 11+00 12+00 12+50SSMH A3STA 10+00.00RIM 5016.6±INV. IN 5009.19 (S)INV. IN 5009.19 (E)INV. OUT 5008.99 (N)82.95 LF 8" PVC @ 0.50%SSMH A2-2STA 11+92.91RIM 5015.5±INV. IN 5010.35 (E)INV. OUT 5010.15 (W)PROPOSED
GROUND
EXISTING
GROUND
109.97 LF 8" PVC @ 0.50%SSERV A2-1STA 10+82.95INV. 5009.60 (E)INV. 5009.60 (S)INV. 5009.60 (W)SVC.8" PVC WATER
STA.=10+10.00
TOP=5011.91
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
C 610PLAN & PROFILESANITARY SEWER LINES A & A329
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
( IN FEET )
1 inch = ft.
Feet05050
50
100 150
PROFILE SCALE:
SANITARY LINE A
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
NOTES:
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.ALL SANITARY CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS WATER AND
WASTEWATER DESIGN CRITERIA.
3.MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF
NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED
WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS
SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND
ARE SUBJECT TO CHANGE IN THE FIELD.
5.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
STROM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES.
6.ALL SINGLE-FAMILY SANITARY SEWER SERVICES TO BE 4" PVC.
7.ALL SANITARY MANHOLES TO BE 4'Ø UNLESS NOTED OTHERWISE.
8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
W
EXISTING STORM SEWER
SPROPOSED SEWER SERVICE
EXISTING SANITARY SEWER SS
PROPOSED AREA STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPOSED LOT LINE
PROJECT BOUNDARY
EXISTING RIGHT OF WAY
W
EASEMENT LINE
PROPOSED RIGHT OF WAY
PROPOSED COMBO STORM INLET
PROPOSED TYPE-R STORM INLET
PROPOSED WATER SERVICE
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
NORTH
PROFILE SCALE:
SANITARY LINE A3
SANITARY
LINE A
SANITARY
LINE A3
NORTH
V.P.VAULTELECSSS18" SS18" SS18" SS18" SS18" SS18" SS21" SS21" SS21" SS21" SS21" SS21" SS21" SS8" SS8" SS8" SSWWWFDCFS EEEUDUD
UDUDUDUDUD
UD
UD UDUDUDUDUDSSSSWWWHYDPROPOSED 4'EEES SSSSWWFFF EEEEE
T
T
GEEEEEESWWW
WFSVAULTELECEEEEWWGGG G G G
EEEEE18" SSWEEEEWGGGW
EEEEEEFDCFDCFDCFDCGFFFSSFSF
F
SF F
GGGGTSWNYLOPLASTDO NOT P
O
L
L
U
T
E
D
R
A
I
N
S
T
O
W
A
T
E
R
W
A
Y
S
NYLOPLASTDO NOT POLLUTE DRAINS TO WATERWAYSEEEVAULTELECVAULTELECEEEEEEW
PROPOSED 8"
PVC WATER
SANITARY LINE C
SEE SHEET C 612
SANITARY LINE A2
SEE SHEET C 610
STORM DRAIN 1
SEE SHEET C 620
27.44 LF
8" PVC
@ 0.58%
PIPE END B4
STA 11+59.90
N: 1449489.95
E: 3113685.33
STORM LINE 1
SEE SHEET C 620
STORM DRAIN 1-8
SEE SHEET C 622
STORM DRAIN 1-9
SEE SHEET C 622
EXISTING 8"
SANITARY SEWER
EXISTING 8"
WATER LINE
EXISTING
UNDERDRAIN
EXISTING 18"
SANITARY SEWER
EXISTING 21"
SANITARY SEWER
PROPOSED
FIRE HYDRANT PROPOSED 4'
CONCRETE PAN
PROPOSED
FIRE HYDRANT
NEW MH CONNECTIONS TO
EXISTING SANITARY SHALL
BE MADE w/ PRECAST MH
CONNECT TO
EXISTING MH
RESHAPE BASE
INSTALL NEW
PRECAST MANHOLE
CONNECT TO
EXISTING SANITARY
SANITARY LINE B1
SEE THIS SHEET-RIGHT
SSMH B3 (OUTSIDE DROP)
STA 11+32.47
N: 1449462.51
E: 3113685.31
SANITARY LINE D
SEE SHEET C 612
SSMH B1
STA 10+00.00
N: 1449330.04
E: 3113685.24
EXISTING 244.98 LF @ 0.58%
67.36 LF
8" PVC
@ 0.40%
STORM LINE 1-5
SEE SHEET C 621
STORM LINE 1-6
SEE SHEET C 621
65.11 LF
8" PVC
@ 0.40%
63.96 LF
4" PVC
@ 2.00%
SSERV B2
STA 10+65.11
N: 1449395.15
E: 3113685.27
BLDG 18 SSERV
INV. OUT=5004.12 (W)
BUILDING 7
BUILDING 4
BUILDING 5
BUILDING 8
BUILDING 18
BUILDING 17
BUILDING 16BUILDING 1527.44 LF
8" PVC
@ 0.58%
PROPOSED
FIRE HYDRANT
ASHLAR DR
4990
4995
5000
5005
5010
5015
5020
5025
5030
4990
4995
5000
5005
5010
5015
5020
5025
5030
9+5010+0011+0012+00
PROPOSED
GROUND
8" PVC WATER
STA.=11+21.69
TOP=5008.29
EXISTING
GROUND
67.36 LF 8" PVC @ 0.40%SSMH B1STA 10+00.00RIM 5014.1±INV. IN 5002.58 (N)INV. IN 5000.99 (E)INV. OUT 5000.99 (W)PIPE END B4STA 11+59.90RIM 5005.7±INV. IN 5004.99 (N)INV. OUT 5004.99 (S)SSMH B3 (OUTSIDE DROP)STA 11+32.47RIM 5012.8±INV. IN 5004.83 (N)INV. IN 5003.31 (W)INV. OUT 5003.11 (S)65.11 LF 8" PVC @ 0.40%SSERV B2STA 10+65.11INV. 5002.84 (N)INV. 5002.84 (E)INV. 5002.84 (S)27.44 LF
8" PVC
@ 0.58%
EXISTING 8" PVC
UNDERDRAIN
STA.=11+18.82
APPROX. INV.=5006.40
V.P.
VAULT
ELEC
S
S
S
18" SS 18" SS 18" SS 18" SS 18" SS
21" SS 21" SS 21" SS 21" SS 21" SS
8" SS 8" SS 8" SSW WW / / / / / / / // / / / / / / /FDC
FS
E E
UD
UDU
D
U
D
U
DUD
UDUDUD
UD UD UDSSSSSSSS
W W W
HY DSSWWFETG
E E
EEEESW
FVAULT
ELEC
EEWG G
E E E
E E E
G G G
EE EEE
FDC
FDCGFFVAULTELECE126.55 LF 8" PVC @ 0.40%
SSMH B3-1
STA 11+26.55
N: 1449464.13
E: 3113558.77
EXISTING 8"
SANITARY SEWER
EXISTING 8"
WATER LINE
EXISTING
UNDERDRAIN
EXISTING 21"
SANITARY SEWER
PROPOSED
FIRE HYDRANT
PROPOSED 4'
CONCRETE PAN
CONNECT TO
EXISTING MH
EXISTING 18"
SANITARY SEWERPROPOSED 8"
PVC WATER
STORM LINE 1-9
SEE SHEET C 622
STORM LINE 1
SEE SHEET C 620
SANITARY LINE B
SEE THIS SHEET-LEFT
SSMH B3 (OUTSIDE DROP)
STA 10+00.00
N: 1449462.51
E: 3113685.31
BUILDING 7
BUILDING 18
BUILDING 8
149.55 LF 8" PVC @ 1.60%
INSTALL NEW
PRECAST MANHOLE
CONNECT TO
EXISTING SANITARY
ASHLAR DR4990
4995
5000
5005
5010
5015
5020
5025
5030
4990
4995
5000
5005
5010
5015
5020
5025
5030
9+5010+0011+0012+00 SSMH B3 (OUTSIDE DROP)STA 10+00.00RIM 5012.8±INV. IN 5004.83 (N)INV. IN 5003.31 (W)INV. OUT 5003.11 (S)SSMH B3-1STA 11+26.55RIM 5014.0±EX. INV. IN 5003.90 (N)EX. INV. IN 5003.97 (W)PROP. INV. OUT 5003.82 (E)126.55 LF 8" PVC @ 0.40%
EXISTING
GROUND
2" HDPE WATER
STA.=10+05.91
INV.=5008.05
2" HDPE WATER
STA.=10+09.52
INV.=5008.00EX. INV. OUT 5003.76 (S, TOBE ABANDONED)EXISTING 8" PVC
UNDERDRAIN
STA.=10+51.96
APPROX. INV.=5007.00
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
C 611PLAN & PROFILESANITARY SEWER LINES B & B330CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
( IN FEET )
1 inch = ft.
Feet05050
50
100 150
PROFILE SCALE:
SANITARY LINE B
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
NOTES:
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.ALL SANITARY CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS WATER AND
WASTEWATER DESIGN CRITERIA.
3.MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF
NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED
WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS
SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND
ARE SUBJECT TO CHANGE IN THE FIELD.
5.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
STROM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES.
6.ALL SINGLE-FAMILY SANITARY SEWER SERVICES TO BE 4" PVC.
7.ALL SANITARY MANHOLES TO BE 4'Ø UNLESS NOTED OTHERWISE.
8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
W
EXISTING STORM SEWER
SPROPOSED SEWER SERVICE
EXISTING SANITARY SEWER SS
PROPOSED AREA STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPOSED LOT LINE
PROJECT BOUNDARY
EXISTING RIGHT OF WAY
W
EASEMENT LINE
PROPOSED RIGHT OF WAY
PROPOSED COMBO STORM INLET
PROPOSED TYPE-R STORM INLET
PROPOSED WATER SERVICE
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
NORTH
SANITARY LINE B3
PROFILE SCALE:
NORTH
SANITARY
LINE B
SANITARY
LINE B3
S SSWWFFEEGGGEEEET
T
GEESWWW
WW
FSSVAULTELECEEUD
UD
UD
WUDEEGGGEEEGGG G G G G
W
EEE18" SSWEWW S
EEETEEE
FDCFDCGFFFFGGS SSFSF
F F
SF F
GGGSWNYLOPLASTDO NOT P
O
L
L
U
T
E
D
R
A
I
N
S
T
O
W
A
T
E
R
W
A
Y
S
NYLOPLASTDO NOT P
O
L
L
U
T
E
D
R
A
I
N
S
T
O
W
A
T
E
R
W
A
Y
S
EEEEEEVAULTELECGEEEEEEEEGEW
B
B
B
B
B
B
B
B
B
B
B
BBB
B
B
BB
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
BBB
B
B
BB
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
BB BBB
B
B
B
BBB
B
B
B
BB B
B
B
B BB
BB
B
B
B
BB
B
BB
B
B
B BB
B BB
B
B
B
B
B BB
B BB
XXX BBBBB
B
B
B
B
X
X
X
X
SS18" SS18" SS18" SS18" SS18" SS18" SS21" SS21" SS21" SS21" SS21" SS21" SS21" SSUDSUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMHHYDMM30" W30" W30" W30" W30" W30" W30" W30" WX
X
X
X
SSMH C1
STA 10+65.27
N: 1449313.92
E: 3113839.00
SSMH C8
STA 12+55.87
N: 1449123.32
E: 3113838.90
PROPOSED 8"
PVC WATER
SANITARY LINE D
SEE THIS SHEET - RIGHT
EXISTING 18"
SANITARY SEWER
PROPOSED
FIRE HYDRANT PROPOSED
FIRE HYDRANT
PROPOSED
RAIN GARDEN
PROPOSED 2'
CONCRETE PAN
CANAL I
M
P
O
R
T
A
T
I
O
N
EXISTING SANITARY
SEWER MANHOLE
PROPOSED 2'
CONCRETE PAN
EXISTING 30"
WATER LINE
NEW MH CONNECTIONS TO
EXISTING SANITARY SHALL
BE MADE W/ PRECAST MH
SANITARY LINE B
SEE SHEET C 611
STORM DRAIN 5
SEE SHEET C 625
EXISTING 21"
SANITARY SEWER
UNDERDRAIN
SEE SHEET C 626
STORM DRAIN 3
SEE SHEET C 623
STORM DRAIN 2
SEE SHEET C 623
BLDG 8
BLDG
4
BLDG 17
BLDG 18
BLDG 16
BLDG 15
BLDG 13 BLDG 12 BLDG 11
BLDG 10 BLDG 9
STORM DRAIN 1-5
SEE SHEET C 621
STORM DRAIN 1-6
SEE SHEET C 621
38.81 LF
8" PVC
@ 0.50%
BLDG 14
BLDG 9 SSERV
INV. OUT=5008.40 (W)
49.42 LF
4" PVC
@ 2.00%
SS BEND w CO C8-3
INV. IN=5007.41 (E)
INV. OUT=5007.41 (N)
11.75 LF
4" PVC
@ 2.00%
SS BEND w CO C8-1
INV. IN=5006.42 (S)
INV. OUT=5006.42 (N)
15.38 LF
4" PVC
@ 2.00%
5.22 LF
8" PVC
@ 0.50%
34.93 LF
4" PVC
@ 2.00%
SS BEND w CO C7-1
INV. IN=5006.58 (SE)
INV. OUT=5006.58 (W)
32.16 LF
4" PVC
@ 2.00%
BLDG 10 SSERV
INV. OUT=5007.23 (NW)
SSMH C
STA 9+99.96
N: 1449313.73
E: 3113904.31
32.17 LF
4" PVC
@ 9.00%
40.13 LF
4" PVC
@ 9.00%
BLDG 15 SSERV
INV. OUT=5007.64 (S)
BLDG 16 SSERV
INV. OUT=5008.35 (SE)
65.30 LF
18" PVC
@ 0.18%
43.48 LF
4" PVC
@ 8.50%
BLDG 17 SSERV
INV. OUT=5008.66 (SE)
SSERV C2
STA 11+04.08
N: 1449275.11
E: 3113838.98
54.62 LF
8" PVC
@ 0.50%
42.74 LF
4" PVC
@ 2.00%
BLDG 14 SSERV
INV. OUT=5006.01 (W)
SSERV C3
STA 11+58.71
N: 1449220.49
E: 3113838.95
43.55 LF
8" PVC
@ 0.50%
42.74 LF
4" PVC
@ 2.00%
BLDG 13 SSERV
INV. OUT=5006.28 (W)
SSERV C4
STA 12+02.26
N: 1449176.94
E: 3113838.93
45.09 LF
4" PVC
@ 2.00%
22.94 LF
8" PVC
@ 0.50%
SSERV C7
STA 12+50.65
N: 1449128.54
E: 3113838.90
SSERV C6
STA 12+45.65
N: 1449133.54
E: 3113838.91
44.91 LF
4" PVC
@ 2.00%
BLDG 11 SSERV
INV. OUT=5006.76 (W)
BLDG 12 SSERV
INV. OUT=5006.55 (W)
SSERV C5
STA 12+25.20
N: 1449153.99
E: 3113838.92
26.76 LF
6" PVC
@ 1.00%
5.00 LF
8" PVC
@ 0.50%
20.45 LF
8" PVC
@ 0.50%
BLDG 8 SSERV
INV. OUT=5006.03 (E)
PROPOSED
FIRE HYDRANT
ASHLAR DR
4990
4995
5000
5005
5010
5015
5020
5025
5030
4990
4995
5000
5005
5010
5015
5020
5025
5030
10+0010+00 11+00 12+00 13+00 13+50SSMH C1STA 10+65.27RIM 5013.3±INV. IN 5003.46 (W)INV. IN 5004.96 (S)INV. IN 5004.96 (NW)INV. OUT 5003.36 (E)38.81 LF
8" PVC
@ 0.50%SSMH C8STA 12+55.87RIM 5013.1±INV. IN 5006.11 (S)INV. OUT 5005.91 (N)8" PVC WATER
STA.=13+30.59
TOP=5008.6124" RCP STORM
STA.=10+93.53
INV.=5009.11
PROPOSED
GROUND
EXISTING
GROUND
8" PVC WATER
STA.=10+82.28
TOP=5008.70 SSERV C2STA 11+04.08INV. 5005.16 (S)INV. 5005.16 (E)INV. 5005.16 (N)SSERV C3STA 11+58.71INV. 5005.43 (S)INV. 5005.43 (E)INV. 5005.43 (N)SSERV C4STA 12+02.26INV. 5005.65 (S)INV. 5005.65 (E)INV. 5005.65 (N)SSERV C5STA 12+25.20INV. 5005.76 (S)INV. 5005.76 (W)INV. 5005.76 (N)SSERV C6STA 12+45.65INV. 5005.86 (S)INV. 5005.86 (E)INV. 5005.86 (N)SSERV C7STA 12+50.65INV. 5005.89 (S)INV. 5005.89 (E)INV. 5005.89 (N)6" PVC WATER
STA.=11+82.65
TOP=5008.86
54.62 LF
8" PVC
@ 0.50%
43.55 LF
8" PVC
@ 0.50%
22.94 LF
8" PVC
@ 0.50%
20.45 LF
8" PVC
@ 0.50%
5.22 LF
8" PVC
@ 0.50%
5.00 LF
8" PVC
@ 0.50%
PROPOSED 20 LF
STEEL CASING PIPE
S SSWWFFEEGGGEEEET
T
GEEEETSWWW
EWW
FSSVAULTELECEEUD
WWUDEEGGGEEEEEGGG G G G GW
EEEE18" SSWEEEWGW S
EEETEEE
FDCFDCFDCGFFFFGGS SSFSF
F F
SF F
GGGGGGSWNYLOPLASTDO NOT POLLUTE DRAINS TO WATERWAYSNYLOPLASTDO NOT POLL
U
T
E
D
R
A
I
N
S
T
O
W
A
T
E
R
W
A
Y
S
EEEEEEEGGVAULTELECGEEEEEEEEGEW
B
B
B
B
BBBB
B
B
BB
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
BBB
B
B
BB
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B BBB
B
B
B
BB
B
B
B
B
B
B
B
B
B BBBBB
B
B
B
BBB
B
B
B
B BBB
B BB
B
B
B
B
B BB
B BB
XXX
SSS18" SS18" SS18" SS18" SS18" SS21" SS21" SS21" SS21" SS21" SS21" SSUDUD UDUDUDUDUDUDUDWWWSUDUDHYDMH30" W30" W30" W30" W30" W30" W30" W30" WPROPOSED 8"
PVC WATER
EXISTING 21"
SANITARY SEWER
PROPOSED
FIRE HYDRANT PROPOSED
FIRE HYDRANT
PROPOSED 2'
CONCRETE PAN
PROPOSED 4'
CONCRETE PAN
EXISTING SANITARY
SEWER MANHOLE
PROPOSED 2'
CONCRETE PAN
EXISTING 30"
WATER LINE
STORM DRAIN 1
SEE SHEET C 620
SANITARY LINE B
SEE SHEET C 611
EXISTING 21"
SANITARY SEWER
183.88 LF 8" PVC @ 2.00%
SSMH D3
STA 11+90.27
N: 1449124.21
E: 3113685.13
SSMH D1
STA 10+00.00
N: 1449314.48
E: 3113685.23
BLDG 17
BLDG 18
BLDG 16
BLDG 15
BLDG
4
BLDG
7
BLDG 13 BLDG 12 BLDG 11
BLDG 10 BLDG 9
BLDG 14
BLDG 8
BLDG
5
6.39 LF 8" PVC @ 2.00%
SSERV D2
STA 11+83.88
N: 1449130.60
E: 3113685.13
34.55 LF 6" PVC @ 1.00%
BLDG 5 SSERV
INV. OUT=5009.75 (NE)
NEW MH CONNECTIONS TO
EXISTING SANITARY SHALL
BE MADE W/ PRECAST MH
STORM DRAIN 1-5
SEE SHEET C 621
STORM DRAIN 1-8
SEE SHEET C 620
SANITARY LINE C
SEE THIS SHEET - LEFT
PROPOSED
FIRE HYDRANT
ASHLAR DR
4990
4995
5000
5005
5010
5015
5020
5025
5030
4990
4995
5000
5005
5010
5015
5020
5025
5030
9+50 10+00 11+00 12+00 12+50SSMH D1STA 10+00.00RIM 5014.0±INV. IN 5005.72 (S)INV. IN 5004.22 (W)INV. OUT 5004.22 (E)183.88 LF
8
"
P
V
C
@
2
.
0
0
%SSMH D3STA 11+90.27RIM 5014.7±INV. OUT 5009.53 (N)PROPOSED
GROUND
EXISTING
GROUND
8" PVC WATER
STA.=10+62.18
TOP=5010.26
24" RCP STORM
STA.=10+34.79
INV.=5009.51
6.39 LF
8" PVC
@ 2.00%SSERV D2STA 11+83.88INV. 5009.40 (S)INV. 5009.40 (SW)INV. 5009.40 (N)PROPOSED 20 LF
STEEL CASING PIPE
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
C 612PLAN & PROFILESANITARY SEWER LINES C & D31CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
( IN FEET )
1 inch = ft.
Feet05050
50
100 150
PROFILE SCALE:
SANITARY LINE C
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
NOTES:
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.ALL SANITARY CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS WATER AND
WASTEWATER DESIGN CRITERIA.
3.MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF
NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED
WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS
SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND
ARE SUBJECT TO CHANGE IN THE FIELD.
5.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
STROM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES.
6.ALL SINGLE-FAMILY SANITARY SEWER SERVICES TO BE 4" PVC.
7.ALL SANITARY MANHOLES TO BE 4'Ø UNLESS NOTED OTHERWISE.
8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
W
EXISTING STORM SEWER
SPROPOSED SEWER SERVICE
EXISTING SANITARY SEWER SS
PROPOSED AREA STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPOSED LOT LINE
PROJECT BOUNDARY
EXISTING RIGHT OF WAY
W
EASEMENT LINE
PROPOSED RIGHT OF WAY
PROPOSED COMBO STORM INLET
PROPOSED TYPE-R STORM INLET
PROPOSED WATER SERVICE
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
SANITARY
LINES
C & D
SANITARY LINE D
PROFILE SCALE:
EEEEE
EEE SSSSSS
SSWWWFF
FFFEEEEETTGTE E
TEEEEEEEES
WWWW
WFSS
E
VAULT
ELEC
EEE E E EEUDUDUDWWG G
GGGGGW
E E E E
EEEE18" SS
WE E E E
W
G G G G G G G G
WSEE EEE E
FDC
FDCFDC FDC
FDCFDCFDCGFFFFGG
SSSFSFFSFFGG G G G GG G G
TSWNYLOPLAST
DO NOT POLLUTE DRAINS TO WATERWAYS
NYLOPLAST
DO NOT POLLUTE DRAINS TO WATERWAYS
EEEEE E E E E EEVAULT
ELEC VAULTELECG EEEEEE
WV.P.
HY D
VAULT
ELEC
S
S
MH
S
S
S
S
S
CONTROL
S HY DS
18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS21" SS21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS
8
"
S
S
8" SS 8" SS 8" SSEGGGGGGGGGW W W W W W W WWWWW FDC
FS UDE
E
E E UDU
D
U
D
U
D
U
DUDUDUD
UD
UD UD UD UD UD UDSSWWW
S
S
UDUDUDUDUDUDUDUDUDUDUDUDUDUDUDHY DMH
S
HY D
MM
MHXXXX XXXXSSSS
2
1
"
S
SXXXXXXXXXXINLET 1-14
STA 19+05.65
N: 1449427.58
E: 3113371.58
STMH 1-9
STA 16+77.56
N: 1449263.33
E: 3113468.37
STMH 1-7
STA 15+40.67
N: 1449263.59
E: 3113605.26
STMH 1-5
STA 14+28.50
N: 1449285.73
E: 3113715.21
INLET 1-3
STA 11+12.59
N: 1449118.06
E: 3113863.44
INLET 1-4
STA 12+80.19
N: 1449285.65
E: 3113863.53
BEND 1-13
STA 18+86.19
N: 1449411.75
E: 3113360.26
TEE 1-12
STA 18+53.78
N: 1449379.34
E: 3113360.25
BEND 1-11
STA 18+15.75
N: 1449341.31
E: 3113360.23
BEND 1-10
STA 17+23.15
N: 1449274.27
E: 3113424.10
TEE 1-8
STA 15+79.84
N: 1449263.61
E: 3113566.09
FES 1-1
STA 10+00.00
N: 1449118.00
E: 3113976.04
99.98 LF 30" HDPE @ 0.20%167.59 LF 30" RCP @ 0.20%148.32 LF 24" RCP @ 0.20%
112.16 LF 24" RCP @ 0.50%
39.17 LF 24" RCP @ 0.50%
97.72 LF 24" RCP @ 0.50%
45.60 LF 8" HDPE @ 0.50%
92.59 LF 8" HDPE @ 0.50%
38.03 LF 8" HDPE @ 0.50%
32.41 LF 8" HDPE @ 0.50%
19.46 LF 8" HDPE @ 0.50%
HOBBIT STREET
LANDMARK
APARTMENTS
EXISTING 18"
SANITARY SEWER
EXISTING 21"
SANITARY SEWER
EXISTING 8" PVC
WATER
PROPOSED FH
PROPOSED FH
PROPOSED FH
PROPOSED FH
PROPOSED
RAIN GARDEN
SANITARY LINE A
SEE SHEET C 610
SANITARY LINE D
SEE SHEET C 612
SANITARY LINE C
SEE SHEET C 612
PROPOSED
GAS PROPOSED
ELECTRIC
SANITARY LINE B
SEE SHEET C 611
SANITARY LINE B1
SEE SHEET C 611
UNDERDRAIN
SEE SHEET C 626
STORM DRAIN 1-9
SEE SHEET C 622
STORM DRAIN 1-8
SEE SHEET C 622
BUILDING 6 BUILDING 7
BUILDING 2
BUILDING 3
BUILDING 4 BUILDING 5 BUILDING 8
BUILDING 18 BUILDING 17
BUILDING 16 BUILDING 15
BUILDING 14
BUILDING 13
BUILDING 12
BUILDING 11
BUILDING 10
BUILDING 9
STORM JOINTS NEED TO
BE WRAPPED 10 FT ON
EITHER SIDE OF WATER
CROSSING
PROPOSED
FOREBAYASHLAR DR4995
5000
5005
5010
5015
5020
5025
5030
4995
5000
5005
5010
5015
5020
5025
5030
9+5010+0011+0012+0013+0014+0015+0016+0017+0018+0019+0020+0020+50
19.46 LF
8" HDPE
@ 0.50%
32.41 LF
8" HDPE
@ 0.50%
38.03 LF
8" HDPE
@ 0.50%BEND 1-11STA 18+15.75RIM 5013.4±INV. IN 5012.63 (N)INV. OUT 5012.63 (SE)92.59 LF
8" HDPE
@ 0.50%BEND 1-10STA 17+23.15RIM 5012.9±INV. IN 5012.16 (NW)INV. OUT 5012.16 (E)45.60 LF
8" HDPE
@ 0.50%STMH 1-9STA 16+77.56RIM 5015.5±INV. IN 5011.94 (W)INV. IN 5010.63 (S)INV. OUT 5010.60 (E)97.72 LF 24" RCP @ 0.50%TEE 1-8STA 15+79.84RIM 5012.5±INV. IN 5010.11 (W)INV. IN 5010.81 (S)INV. OUT 5010.11 (E)39.17 LF
24" RCP
@ 0.50%STMH 1-7STA 15+40.67RIM 5015.3±INV. IN 5009.92 (W)INV. OUT 5009.92 (E)112.16 LF
24" RCP
@ 0.50%STMH 1-5STA 14+28.50RIM 5014.1±INV. IN 5009.78 (NW)INV. IN 5009.36 (S)INV. IN 5009.36 (W)INV. OUT 5009.36 (E)148.32 LF 24" RCP @ 0.20%INLET 1-4STA 12+80.19RIM 5012.9±INV. IN 5009.06 (W)INV. OUT 5009.06 (S)167.59 LF 30" RCP @ 0.20%INLET 1-3STA 11+12.59RIM 5012.5±INV. IN 5008.73 (N)INV. OUT 5008.73 (E)99.98 LF 30" HDPE @ 0.20%FES 1-1STA 10+00.00RIM 5011.3±INV. IN 5008.50 (W)PROPOSED
GROUND EXISTING
GROUND
21" CLAY SANITARY
STA.=18+01.56
INV.=5003.31TEE 1-12STA 18+53.78RIM 5013.7±INV. IN 5012.82 (N)INV. IN 5012.94 (E)INV. OUT 5012.82 (S)8" PVC WATER
STA.=14+48.90
TOP=5007.73
18" MIN.
8" PVC WATER
STA.=12+91.73
TOP=5007.33
18" MIN.
18" CLAY SANITARY
STA.=17+81.04
INV.=5005.73
8" PVC SANITARY
STA.=14+59.11
INV.=5006.42
PRIVATE
BEND 1-13STA 18+86.19RIM 5013.7±INV. IN 5012.98 (NE)INV. OUT 5012.98 (S)TEE 1-2STA 10+12.61INV. 5008.53 (W)INV. 5008.64 (S)INV. 5008.53 (E)4" PVC WATER
STA.=12+54.63
TOP=5007.30
4" PVC WATER
STA.=12+25.01
TOP=5007.25
4" PVC WATER
STA.=11+81.46
TOP=5006.19
4" PVC WATER
STA.=11+38.07
TOP=5005.98
4" PVC SANITARY
STA.=12+69.63
INV.=5005.65
4" PVC SANITARY
STA.=12+15.01
INV.=5005.92
4" PVC SANITARY
STA.=11+71.46
INV.=5006.14
4" PVC SANITARY
STA.=11+28.07
INV.=5006.35
4" PVC SANITARY
STA.=10+91.76
INV.=5006.88
4" PVC SANITARY
STA.=11+23.05
INV.=5006.38
12.61 LF
30" HDPE
@ 0.20%
2-YR HGL
8" PVC SANITARY
STA.=13+04.73
INV.=5005.10
FLOW FILL
BETWEEN PIPES
ALL CROSSINGS SHALL BE
WRAPPED 10 FT EACH
SIDE PER DETAIL 205
STEEL CASING PIPE
STA.=14+59.11
INV.=5006.00INLET 1-14STA 19+05.65RIM 5015.7±INV. OUT 5013.08 (SW)SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
C 620PLAN & PROFILESTORM DRAIN 132
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
NORTH
( IN FEET )
1 inch = ft.
Feet05050
50
100 150
PROFILE SCALE:
STORM DRAIN 1
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
NOTES:
W
EXISTING SANITARY SEWER SS
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPOSED LOT LINE
PROJECT BOUNDARY
EXISTING RIGHT OF WAY
EXISTING STORM SEWER
EASEMENT LINE
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES.
3.PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND
STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF
FLARED END SECTIONS.
4.ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND
INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY CITY OF
FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE
R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE
'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443
FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE).
5.CONTRACTOR SHALL CONFIRM THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR
THEIR PROPOSED METHODS OF INSTALLATION (i.e., WITHIN PRE-CASTER'S
TOLERANCES, ETC.).
6.CONTRACTOR SHALL DEFLECT SERVICE LINES TO AVOID STORM DRAIN LINES BY 18"
VERTICALLY.
PROPOSED RIGHT OF WAY
INLET SUMMARY TABLE
DESIGN
POINT
DESIGN INLET
LABEL INLET TYPE INLET SIZE
A2 INLET 2-5 Area Inlet 2' X 15'
B1 INLET 3-4 Nyoplast 30 in.30"
B2 INLET 1-3 Nyloplast 3'X3' (36"
basin)3' X 3'
B3 INLET 1-4 Nyloplast 3'X3' (36"
basin)3' X 3'
B6 INLET 1-9.5 Type R 5'
B7 INLET 1-9.1 Type R 5'
B9 INLET 1-5.1 Type R 5'
B10 INLET 1-6.3 Type R 5'
D3 INLET 6-2 Type R 5'
D5 INLET 4-4A Nyloplast 3'X3' (30"
basin)3' X 3'
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
STORM
DRAIN 1
S SSWWFFFEEEEE
T
T
GEEEEETSWWW
EWW
FSSVAULTELECVAULTELECEEWWUDGGGEEEGGG G G G G
W
EEEEE18" SSWEEEWGGW S
EEETEEE
FDCFDCFDCGFFFFGGS SSFSF
F F
SF F
GGGGGSWNYLOPLASTDO NOT P
O
L
L
U
T
E
D
R
A
I
N
S
T
O
W
A
T
E
R
W
A
Y
S
NYLOPLASTDO NOT POLL
U
T
E
D
R
A
I
N
S
T
O
W
A
T
E
R
W
A
Y
S
EEEEEEEGGVAULTELECGEEEEEEEEGEWV.P.VAULTELECSSS18" SS18" SS18" SS18" SS21" SS21" SS21" SS21" SS21" SS21" SS8" SS8" SSWFDCEEUDUDUDUD
UD UDUDUDUDUDUDWWWH YD30" W30" W30" W30" W30" W30" W30" WLANDMARK
APARTMENTS
EXISTING 21"
SANITARY SEWER
EXISTING 8" PVC
WATER
PROPOSED FH
SANITARY LINE D
SEE SHEET C 612
PROPOSED GAS
PROPOSED
ELECTRIC
STORM DRAIN 1
SEE SHEET C 620
EXISTING 18"
SANITARY SEWER
EXISTING 30"
WATER
STORM DRAIN 1-8
SEE SHEET C 622
50.16 LF 15" RCP @ 1.
0
0
%
STMH 1-5
STA 10+00.00
N: 1449285.73
E: 3113715.21
INLET 1-5.1
STA 11+19.02
N: 1449167.00
E: 3113706.82
BUILDING 7
BUILDING 4
BUILDING 5
BUILDING 8
BUILDING 18
BUILDING 17
BUILDING 16
BUILDING 15 BUILDING 14
BUILDING 13
BUILDING 12
BUILDING 11
BUILDING 10
PROPOSED FH
STORM DRAIN 1-6
SEE THIS SHEET - RIGHT
SANITARY LINE C
SEE SHEET C 612
ALL CROSSINGS SHALL BE
WRAPPED 10 FT EACH
SIDE PER DETAIL 205 ASHLAR DR
4995
5000
5005
5010
5015
5020
5025
5030
4995
5000
5005
5010
5015
5020
5025
5030
9+50 10+00 11+00 11+50
PRIVATE
STMH 1-5STA 10+00.00RIM 5014.1±INV. IN 5009.78 (NW)INV. IN 5009.36 (S)INV. IN 5009.36 (W)INV. OUT 5009.36 (E)50.16 LF
15" RCP
@ 1.00%INLET 1-5.1STA 11+19.02RIM 5014.1±INV. IN 5011.46 (E)INV. IN 5010.54 (S)INV. OUT 5010.54 (N)EXISTING
GROUND
PROPOSED
GROUND BLDG 8 RD TEE 1STA 10+50.16RIM 5011.4±INV. IN 5009.86 (S)INV. IN 5010.78 (E)INV. OUT 5009.86 (N)41.93 LF
15" RCP
@ 1.00%BLDG 5 RD TEE 1STA 10+92.09RIM 5011.8±INV. IN 5010.28 (S)INV. IN 5010.78 (W)INV. OUT 5010.28 (N)21.27 LF
15" RCP
@ 0.97%BLDG 5 RD TEE 2STA 11+13.37RIM 5012.0±INV. IN 5010.48 (S)INV. IN 5011.40 (W)INV. OUT 5010.48 (N)5.66 LF
15" RCP
@ 1.00%
S SSWWFFFEEEEE
T
T
GEEEEESWWW
WW
FSSVAULTELECEEWWGGG G G G GW
EEEE18" SSWEEEWGGW S
EEEEEEFDCFDCFDCGFFFFGGS SSFSF
F F
SF F
GGGSWNYLOPLASTDO NOT P
O
L
L
U
T
E
D
R
A
I
N
S
T
O
W
A
T
E
R
W
A
Y
S
NYLOPLASTDO NOT POLLUTE DRAINS TO WATERWAYSEEEEVAULTELECEEEEEEW
V.P.VAULTELECSSS18" SS18" SS18" SS18" SS18" SS21" SS21" SS21" SS21" SS21" SS8" SS8" SSWFDCS EEEEUDUD
UDUDUDUDUDUD
UD
UD UDUDUDUDUDUDSSSSWWWHYDLANDMARK
APARTMENTS
EXISTING 21"
SANITARY SEWER
EXISTING 8" PVC
WATER
PROPOSED FH
SANITARY LINE D
SEE SHEET C 612
PROPOSED GAS
PROPOSED
ELECTRIC
STORM DRAIN 1
SEE SHEET C 620
EXISTING 18"
SANITARY SEWER
EXISTING 30"
STORM DRAIN 1-8
SEE SHEET C 622
52.61 LF
8" HDPE
@ 0.37%
TEE 1-6.2
STA 10+65.70
N: 1449347.60
E: 3113706.00
23.81 LF
8" HDPE
@ 0.40%
INLET 1-6.3
STA 10+89.51
N: 1449371.37
E: 3113707.43
26.35 LF
8" HDPE
@ 0.40%
INLET 1-6.4
STA 11+15.85
N: 1449385.12
E: 3113729.90
BEND 1-6.1
STA 10+13.08
N: 1449294.98
E: 3113705.97
13.08 LF 8" HDPE @ 0.48%
STORM DRAIN 1-5
SEE THIS SHEET - LEFT
BUILDING 7
BUILDING 4
BUILDING 5
BUILDING 8
BUILDING 18
BUILDING 17
BUILDING 16
BUILDING 15 BUILDING 14
BUILDING 13
BUILDING 12
BUILDING 11
BUILDING 10
PROPOSED FH
SANITARY LINE C
SEE SHEET C 612
ALL CROSSINGS SHALL BE
WRAPPED 10 FT EACH
SIDE PER DETAIL 205 ASHLAR DR
4995
5000
5005
5010
5015
5020
5025
5030
4995
5000
5005
5010
5015
5020
5025
5030
9+009+0010+0011+0012+00
PRIVATE
EXISTING
GROUND
PROPOSED
GROUND
13.08 LF
8" HDPE
@ 0.48%BEND 1-6.1STA 10+13.08INV. 5009.85 (N)INV. 5009.85 (SE)52.61 LF
8" HDPE
@ 0.37%TEE 1-6.2STA 10+65.70INV. 5010.04 (N)INV. 5010.17 (W)INV. 5010.04 (S)23.81 LF
8" HDPE
@ 0.40%INLET 1-6.3STA 10+89.51RIM 5013.0±INV. IN 5010.14 (NE)INV. OUT 5010.14 (S)26.35 LF
8" HDPE
@ 0.40%INLET 1-6.4STA 11+15.85RIM 5011.6±INV. OUT 5010.24 (SW)EXISTING 24" PVC SANITARY
STA.=10+47.94
INV.=5000.86
8" PVC WATER
STA.=10+15.08
TOP=5008.24
EXISTING 18" PVC SANITARY
STA.=10+32.46
INV.=5004.12
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
C 621PLAN & PROFILESTORM DRAINS 1-5 & 1-633
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
( IN FEET )
1 inch = ft.
Feet05050
50
100 150
PROFILE SCALE:
STORM DRAIN 1-5
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
NOTES:
W
EXISTING SANITARY SEWER SS
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPOSED LOT LINE
PROJECT BOUNDARY
EXISTING RIGHT OF WAY
EXISTING STORM SEWER
EASEMENT LINE
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES.
3.PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND
STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF
FLARED END SECTIONS.
4.ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND
INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY CITY OF
FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE
R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE
'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443
FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE).
5.CONTRACTOR SHALL CONFIRM THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR
THEIR PROPOSED METHODS OF INSTALLATION (i.e., WITHIN PRE-CASTER'S
TOLERANCES, ETC.).
6.CONTRACTOR SHALL DEFLECT SERVICE LINES TO AVOID STORM DRAIN LINES BY 18"
VERTICALLY.
PROPOSED RIGHT OF WAY
INLET SUMMARY TABLE
DESIGN
POINT
DESIGN INLET
LABEL INLET TYPE INLET SIZE
A2 INLET 2-5 Area Inlet 2' X 15'
B1 INLET 3-4 Nyoplast 30 in.30"
B2 INLET 1-3 Nyloplast 3'X3' (36"
basin)3' X 3'
B3 INLET 1-4 Nyloplast 3'X3' (36"
basin)3' X 3'
B6 INLET 1-9.5 Type R 5'
B7 INLET 1-9.1 Type R 5'
B9 INLET 1-5.1 Type R 5'
B10 INLET 1-6.3 Type R 5'
D3 INLET 6-2 Type R 5'
D5 INLET 4-4A Nyloplast 3'X3' (30"
basin)3' X 3'
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
STORM
DRAINS
1-5 & 1-6
PROFILE SCALE:
STORM DRAIN 1-6
NORTH
EEES
SSSWWFF EEEGGGGGEEEEEEEEEETTTEFVAULTELECEEEEEEWWEGGUDEEEEEEGEEEEEEWEEEES
SET
FDCFDCFDCGGGGGGGGGGGGGGTE EEEEEEEGGVAULTELECVAULTELECGGGEE
NYLOPLASTDO NOT P
O
L
L
U
T
E
D
R
A
I
N
S
T
O
W
A
T
E
R
W
A
Y
SSSS
S18" SS18" SS18" SS18" SS18" SS18" SS21" SS21" SS21" SS21" SS21" SS21" SS30" W30" W30" W30" W30" W30" W30" W30" WB
B
B
B
B
B
B
B
B
B
B
BB
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
BB
B
B
B
B
B
B
B
B
B
B
B
EXISTING 21"
SANITARY SEWER
PROPOSED FH SANITARY LINE B
SEE SHEET C 612
TEE 1-8
STA 10+00.00
N: 1449263.61
E: 3113566.09
86.73 LF 8" HDPE @ 0.50%
BASIN 1-8.1
STA 10+86.73
N: 1449176.89
E: 3113565.94
107.78 LF 8" HDPE @ 0.50%
BASIN 1-8.2
STA 11+94.51
N: 1449069.11
E: 3113565.89
STORM DRAIN 4
SEE SHEET C 624
STORM DRAIN 4-4A
SEE SHEET C 624
STORM DRAIN 4-4B
SEE SHEET C 624
6'
T
R
A
I
L
STORM DRAIN 5
SEE SHEET C 625
PROPOSED GAS
PROPOSED
ELECTRIC
STORM DRAIN 1
SEE SHEET C 620
EXISTING 18"
SANITARY SEWER
PROPOSED
RETAINING WALL
EXISTING 30"
WATER
STORM DRAIN 1-9
SEE THIS SHEET - RIGHT
BUILDING
7
BUILDING
6
BUILDING
5
BUILDING
4
BUILDING
2
STORM DRAIN 1-5
SEE SHEET C 621
STORM JOINTS NEED TO
BE WRAPPED 10 FT EACH
SIDE OF CROSSING
PROPOSED FIRE
HYDRANT
ASHLAR DR
4995
5000
5005
5010
5015
5020
5025
5030
4995
5000
5005
5010
5015
5020
5025
5030
9+50 10+00 11+00 12+00 12+50TEE 1-8STA 10+00.00RIM 5012.5±INV. IN 5010.11 (W)INV. IN 5010.81 (S)INV. OUT 5010.11 (E)86.73 LF 8" HDPE @ 0.50%BASIN 1-8.1STA 10+86.73RIM 5014.2±INV. IN 5011.24 (S)INV. OUT 5011.24 (N)107.78 LF 8" HDPE @ 0.50%BASIN 1-8.2STA 11+94.51RIM 5013.9±INV. OUT 5011.78 (N)EXISTING
GROUND
PROPOSED
GROUND
8" PVC WATER
STA.=10+11.25
TOP=5009.30
PRIVATE
18" MIN.EEES
SSSWWFF EEEGGGGGEEEEEEEEEETTTEFVAULTELECEEEEEEWWEGGUDEEEEEEGEEEEEEWEEEES
SET
FDCFDCFDCGGGGGGGGGGGGGGTE EEEEEEEGGVAULTELECVAULTELECGGGEE
NYLOPLASTDO NOT P
O
L
L
U
T
E
D
R
A
I
N
S
T
O
W
A
T
E
R
W
A
Y
SSSS
S18" SS18" SS18" SS18" SS18" SS18" SS21" SS21" SS21" SS21" SS21" SS21" SS30" W30" W30" W30" W30" W30" W30" W30" WB
B
B
B
B
B
B
B
B
B
B
BBB
B
B
BB
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
BBB
B
B
BB
B
B
B
B
B
B
EXISTING 21"
SANITARY SEWER
PROPOSED FH SANITARY LINE B
SEE SHEET C 612
STORM DRAIN 4
SEE SHEET C 624
STORM DRAIN 4-4A
SEE SHEET C 624
STORM DRAIN 4-4B
SEE SHEET C 624
6'
T
R
A
I
L
STORM DRAIN 5
SEE SHEET C 625
PROPOSED GAS
PROPOSED
ELECTRIC
STMH 1-9
STA 10+00.00
N: 1449263.33
E: 3113468.37
31.29 LF
24" RCP
@ 0.50%
TEE 1-9.2
STA 10+51.45
N: 1449211.97
E: 3113468.34
19.31 LF
15" HDPE
@ 0.50%
TEE 1-9.4
STA 10+97.80
N: 1449165.61
E: 3113468.32
30.03 LF
15" HDPE
@ 0.50%
STORM DRAIN 1
SEE SHEET C 620
EXISTING 18"
SANITARY SEWER
PROPOSED
RETAINING WALL
EXISTING 30"
WATER
STORM DRAIN 1-8
SEE THIS SHEET - LEFT
BUILDING
7
BUILDING
6
BUILDING
5
BUILDING
4
BUILDING
2
STORM DRAIN 1-5
SEE SHEET C 621
INLET 1-9.5
STA 11+27.84
N: 1449135.62
E: 3113469.80
9.78 LF
12" HDPE
@ 0.50%
BEND 1-9.6
STA 11+37.62
N: 1449130.47
E: 3113478.11
5.56 LF
12" HDPE
@ 0.50%
TEE 1-9.7
STA 11+43.19
N: 1449124.91
E: 3113478.11
18.86 LF
12" HDPE
@ 0.50%
TEE 1-9.8
STA 11+62.04
N: 1449106.05
E: 3113478.10
11.80 LF 12" HDPE @ 0.50%
TEE 1-9.9
STA 11+69.40
N: 1449094.25
E: 3113478.09
TEE 1-9.3
STA 10+71.13
N: 1449192.66
E: 3113468.33
INLET 1-9.1
STA 10+31.70
N: 1449232.08
E: 3113469.85
20.17 LF
15" HDPE
@ 0.50%
STORM JOINTS NEED TO
BE WRAPPED 10 FT EACH
SIDE OF CROSSING
PROPOSED FIRE
HYDRANT
ASHLAR DR
4995
5000
5005
5010
5015
5020
5025
5030
4995
5000
5005
5010
5015
5020
5025
5030
9+009+00 10+00 11+00 12+00 13+00
EXISTING
GROUND
PROPOSED
GROUND
30.03 LF
15" HDPE
@ 0.50%
19.31 LF
15" HDPE
@ 0.50%
31.29 LF
24" RCP
@ 0.50%
20.17 LF
15" HDPE
@ 0.50%
9.78 LF
12" HDPE
@ 0.50%
5.56 LF
12" HDPE
@ 0.50%
8" PVC WATER
STA.=10+10.93
TOP=5008.93
PRIVATE
STMH 1-9STA 10+00.00RIM 5015.5±INV. IN 5011.94 (W)INV. IN 5010.63 (S)INV. OUT 5010.60 (E)INLET 1-9.1STA 10+31.29RIM 5015.4±INV. IN 5010.79 (S)INV. OUT 5010.79 (N)TEE 1-9.2STA 10+51.45INV. 5010.89 (S)INV. 5011.18 (E)INV. 5010.89 (N)TEE 1-9.3STA 10+70.75INV. 5010.98 (S)INV. 5011.27 (E)INV. 5010.98 (N)TEE 1-9.4STA 10+97.80INV. 5011.12 (S)INV. 5011.49 (E)INV. 5011.41 (W)INV. 5011.12 (N)INLET 1-9.5STA 11+27.84RIM 5015.4±INV. IN 5011.27 (SE)INV. OUT 5011.27 (N)BEND 1-9.6STA 11+37.62INV. 5011.32 (S)INV. 5011.32 (NW)TEE 1-9.7STA 11+43.19INV. 5011.60 (E)INV. 5011.34 (S)INV. 5011.34 (N)TEE 1-9.8STA 11+62.04INV. 5011.44 (S)INV. 5011.59 (E)INV. 5011.44 (N)TEE 1-9.10STA 11+79.51INV. 5011.46 (E)INV. 5011.69 (S)INV. 5011.69 (N)INLET 1-9.11STA 12+10.79RIM 5015.0±INV. OUT 5011.85 (N)27.04 LF
15" HDPE
@ 0.50%
18.86 LF
12" HDPE
@ 0.50%
11.80 LF
12" HDPE
@ 0.50%
5.67 LF
8" HDPE
@ 0.50%
31.29 LF
8" HDPE
@ 0.50%
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
C 622PLAN & PROFILESTORM DRAINS 1-8 & 1-934
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
( IN FEET )
1 inch = ft.
Feet05050
50
100 150
PROFILE SCALE:
STORM DRAIN 1-8
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
NOTES:
W
EXISTING SANITARY SEWER SS
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPOSED LOT LINE
PROJECT BOUNDARY
EXISTING RIGHT OF WAY
EXISTING STORM SEWER
EASEMENT LINE
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES.
3.PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND
STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF
FLARED END SECTIONS.
4.ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND
INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY CITY OF
FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE
R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE
'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443
FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE).
5.CONTRACTOR SHALL CONFIRM THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR
THEIR PROPOSED METHODS OF INSTALLATION (i.e., WITHIN PRE-CASTER'S
TOLERANCES, ETC.).
6.CONTRACTOR SHALL DEFLECT SERVICE LINES TO AVOID STORM DRAIN LINES BY 18"
VERTICALLY.
PROPOSED RIGHT OF WAY
INLET SUMMARY TABLE
DESIGN
POINT
DESIGN INLET
LABEL INLET TYPE INLET SIZE
A2 INLET 2-5 Area Inlet 2' X 15'
B1 INLET 3-4 Nyoplast 30 in.30"
B2 INLET 1-3 Nyloplast 3'X3' (36"
basin)3' X 3'
B3 INLET 1-4 Nyloplast 3'X3' (36"
basin)3' X 3'
B6 INLET 1-9.5 Type R 5'
B7 INLET 1-9.1 Type R 5'
B9 INLET 1-5.1 Type R 5'
B10 INLET 1-6.3 Type R 5'
D3 INLET 6-2 Type R 5'
D5 INLET 4-4A Nyloplast 3'X3' (30"
basin)3' X 3'
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
STORM
DRAINS
1-8 & 1-9
PROFILE SCALE:
STORM DRAIN 1-9
NORTH
4995
5000
5005
5010
5015
5020
5025
5030
4995
5000
5005
5010
5015
5020
5025
5030
9+5010+0011+0011+50
40.32 LF
18" RCP
@ 1.20%
4.75 LF
18" RCP
@ 0.20%BASIN 2-2 (w WEIR)STA 10+30.08RIM 5012.8±INV. IN 5008.11 (N)INV. IN 5008.52 (W)INV. OUT 5008.11 (S)30.08 LF
18" HDPE
@ 0.20%PIPE END 2-1STA 10+00.00RIM 5009.8±INV. IN 5008.05 (N)4.75 LF
18" RCP
@ 0.20%BASIN 2-3STA 10+34.83RIM 5012.7±INV. IN 5008.12 (N)INV. IN 5008.51 (W)INV. OUT 5008.12 (S)PRIVATE
INLET 2-5STA 10+79.90RIM 5011.5±INV. OUT 5008.62 (SW)BASIN 2-4STA 10+39.58RIM 5012.6±INV. IN 5008.13 (NE)INV. IN 5008.56 (W)INV. OUT 5008.13 (S)PROPOSED
GROUND
EXISTING
GROUND
2-YR HGL
18" MIN.
FLOW FILL OVER
30" WATER MAIN
30" WATER
STA.=10+63.94
TOP=5006.68
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B BB
B
B
B
B
B
B
B
B
B
B
BB B
B
B
B BB
BB
B
B
B
B
B
B
B
B
B
B
B BB
B BB
B
B
B
B
B BB
B BB
X BBBBB
B
B
B
B
X
X
MHUDUDUDUDUDUDUDUDUDUDMHX30" W30" W30" W30" WX
X
X
X
X
X
X X
X
30" W21" SS 21" SS21" SS
EW
UD
UD
UDEGG G
EEW S
S SF F
SWNYLOPLASTDO NOT POLLUTE DRAINS TO WATERWAYSEEEGOVERFLOW BASIN 3-4
STA 11+30.88
N: 1449013.73
E: 3114045.32
45.71 LF 24" HDPE @ 0.50%
STMH 3-3
STA 10+85.18
N: 1448971.00
E: 3114061.55
47.07 LF 24" HDPE @ 0.50%
STMH 3-2
STA 10+38.11
N: 1448924.04
E: 3114064.79
39.74 LF
24" HDPE
@ 0.50%
FES 3-1
STA 9+98.37
N: 1448911.11
E: 3114027.21
CANAL IMPOR
T
A
T
I
O
N
SPRING CREEKWALL
E
N
B
E
R
G
D
R
BUILDING 10
BUILDING 9
PROPOSED 2'
CONCRETE PAN
PROPOSED GAS
EXISTING 30"
WATER
STORM DRAIN 5
SEE SHEET C 625
STORM DRAIN 5-2
SEE SHEET C 625
PROPOSED STORM
CHAMBERS 1
FIRE HYDRANT
UNDERDRAIN
SEE SHEET C 626
RAIN
GARDEN
STORM DRAIN 1
SEE SHEET C 620
STORM JOINTS NEED TO
BE WRAPPED 10 FT ON
EITHER SIDE OF CROSSING
4995
5000
5005
5010
5015
5020
5025
5030
4995
5000
5005
5010
5015
5020
5025
5030
9+5010+0011+0012+00
PROPOSED
GROUND
EXISTING
GROUND 100-YR
HGL
18" MIN.
45.71 LF
24" HDPE
@ 0.50%
47.07 LF
24" HDPE
@ 0.50%
39.74 LF
24" HDPE
@ 0.50%OVERFLOW BASIN 3-4STA 11+30.88RIM 5010.5±INV. IN 5008.31 (W)INV. OUT 5008.31 (S)STMH 3-3STA 10+85.18RIM 5012.8±INV. IN 5008.08 (N)INV. OUT 5008.08 (S)STMH 3-2STA 10+38.11RIM 5012.0±INV. IN 5007.84 (N)INV. OUT 5007.84 (W)FES 3-1STA 9+98.37RIM 5009.1±INV. IN 5007.64 (E)PRIVATE
FLOW FILL OVER
30" WATER MAIN
30" WATER
STA.=11+07.89
TOP=5006.18
B
B
B
B
B
B
B
B
B
B
B
BB B
B BB
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B BBBB
B
B
B
B
B
B
B
B
B
B
B BB
B BB
B
B
B
B
B BB
B BB
X BBBBBB
B
B
B
X
X
MHUDUDUDUDUDUDUDUDUDUDMHX30" W30" W30" W30" WX
X
X
X
X
X
X X
X
30" WWINNE GRANT R/JOHNELLE S1821 WALLENBERG DRERIKSEN CHRISTOPHER M1825 WALLENBERG DR21" SS 21" SS 21" SS
EW
UD
UD
UDEGG G
EEW S
S SF F
SWNYLOPLASTDO NOT POLLUTE DRAINS TO WATERWAYSEEEGCANAL IMPOR
T
A
T
I
O
N
SPRING CREEKWALL
E
N
B
E
R
G
D
R
BUILDING 10
BUILDING 9
PROPOSED 2'
CONCRETE PAN
PROPOSED GAS
EXISTING 30"
WATER
STORM DRAIN 5
SEE SHEET C 625
STORM DRAIN 5-2
SEE SHEET C 625
PROPOSED STORM
CHAMBERS 1
FIRE HYDRANT
UNDERDRAIN
SEE SHEET C 626
3 - 78.12 LF 30"x19" CONCRETE ELLIPTICAL PIPE @ 1.75%
STORM DRAIN 2
SEE THIS SHEET - LEFT
STORM DRAIN 3
SEE THIS SHEET - RIGHT
PIPE END 2-1A
STA 10+00.00
N: 1448934.16
E: 3113964.02
INLET 2-5A
STA 10+76.32
N: 1449003.52
E: 3113996.34
RAIN
GARDEN
STORM JOINTS NEED TO
BE WRAPPED 10 FT EACH
SIDE OF CROSSING
STORM DRAIN 1
SEE SHEET C 620
4990
4995
5000
5005
5010
5015
5020
5025
4990
4995
5000
5005
5010
5015
5020
5025
9+5010+0011+0011+50
3 - 76.52 LF 30"x19" CONCRETE
ELLIPTICAL PIPE @ 1.79%PIPE END 2-1ASTA 10+00.00RIM 5009.9±INV. IN 5007.97 (NE)INLET 2-5ASTA 10+76.32RIM 5011.3±INV. OUT 5009.34 (SW)PRIVATE
PROPOSED
GROUND
EXISTING
GROUND
100-YR
HGL
18" MIN.
FLOW FILL OVER
30" WATER MAIN
30" WATER
STA.=10+67.95
TOP=5006.58
B
B
B
B
B
B
B
B
B
B
B
BB B
B BB
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B BBBB
B
B
B
B
B
B
B
B
B
B
B BB
B BB
B
B
B
B
B BB
B BB
X BBBBBB
B
B
B
X
X
MHUDUDUDUDUDUDUDUDUDUDMHX30" W30" W30" W30" WX
X
X
X
X
X
X X
X
30" WWINNE GRANT R/JOHNELLE S1821 WALLENBERG DRERIKSEN CHRISTOPHER M1825 WALLENBERG DR21" SS 21" SS 21" SS
EW
UD
UD
UDEGG G
EEW S
S SF F
SWNYLOPLASTDO NOT POLLUTE DRAINS TO WATERWAYSEEEGINLET 2-5
STA 10+79.90
N: 1449004.76
E: 3113993.09
40.32 LF 18" RCP @ 1.20%
BASIN 2-4
STA 10+39.58
N: 1448973.97
E: 3113967.05
4.75 LF 18" RCP @ 0.20%
BASIN 2-2 (w WEIR)
STA 10+30.08
N: 1448964.47
E: 3113967.05
30.08 LF 18" HDPE @ 0.20%
PIPE END 2-1
STA 10+00.00
N: 1448935.08
E: 3113960.64
CANAL IMPOR
T
A
T
I
O
N
SPRING CREEKWALL
E
N
B
E
R
G
D
R
BUILDING 10
BUILDING 9
PROPOSED 2'
CONCRETE PAN
PROPOSED GAS
EXISTING 30"
WATER
STORM DRAIN 5
SEE SHEET C 625
STORM DRAIN 5-2
SEE SHEET C 625
PROPOSED STORM
CHAMBERS 1
FIRE HYDRANT
STORM DRAIN 3
SEE THIS SHEET - RIGHT
UNDERDRAIN
SEE SHEET C 626
BASIN 2-3
STA 10+34.83
N: 1448969.22
E: 3113967.05
4.75 LF 18" RCP @ 0.20%
RAIN
GARDEN
STORM JOINTS NEED TO
BE WRAPPED 10 FT EACH
SIDE OF CROSSING
STORM DRAIN 1
SEE SHEET C 620
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
C 623PLAN & PROFILESTORM DRAIN 2, 2A, & 335
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
NORTH
( IN FEET )
1 inch = ft.
Feet05050
50
100 150
PROFILE SCALE:
STORM DRAIN 2
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
NOTES:
W
EXISTING SANITARY SEWER SS
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPOSED LOT LINE
PROJECT BOUNDARY
EXISTING RIGHT OF WAY
EXISTING STORM SEWER
EASEMENT LINE
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES.
3.PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND
STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF
FLARED END SECTIONS.
4.ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND
INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY CITY OF
FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE
R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE
'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443
FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE).
5.CONTRACTOR SHALL CONFIRM THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR
THEIR PROPOSED METHODS OF INSTALLATION (i.e., WITHIN PRE-CASTER'S
TOLERANCES, ETC.).
6.CONTRACTOR SHALL DEFLECT SERVICE LINES TO AVOID STORM DRAIN LINES BY 18"
VERTICALLY.
PROPOSED RIGHT OF WAY
INLET SUMMARY TABLE
DESIGN
POINT
DESIGN INLET
LABEL INLET TYPE INLET SIZE
A2 INLET 2-5 Area Inlet 2' X 15'
B1 INLET 3-4 Nyoplast 30 in.30"
B2 INLET 1-3 Nyloplast 3'X3' (36"
basin)3' X 3'
B3 INLET 1-4 Nyloplast 3'X3' (36"
basin)3' X 3'
B6 INLET 1-9.5 Type R 5'
B7 INLET 1-9.1 Type R 5'
B9 INLET 1-5.1 Type R 5'
B10 INLET 1-6.3 Type R 5'
D3 INLET 6-2 Type R 5'
D5 INLET 4-4A Nyloplast 3'X3' (30"
basin)3' X 3'
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
STORM DRAIN 3
PROFILE SCALE:
STORM
DRAIN
2 & 3
STORM DRAIN 2A
PROFILE SCALE:
ESWFFE
E
E
E
E
E
G G G G G
G
G
G
G
G GF
TT
TEE E E E
WW
UD EE E
E E EEEEEEEE
SSEFDC
FDCFDC
W
GGGG G G G G G GG GEEE
E EEGGG
GGIRNYLOPLAST
DO NOT POLLUTE DRAINS TO WATERWAYS
ELEC
30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W
BFES 4-1
STA 10+00.00
N: 1448734.73
E: 3113345.36
13.92 LF 18" HDPE @ 0.50%
BASIN 4-3 (w WEIR)
STA 11+37.27
N: 1448828.58
E: 3113428.48
STMH 4-4
STA 12+82.47
N: 1448973.78
E: 3113428.56
75.80 LF 24" RCP @ 0.50%
STMH 4-2
STA 10+75.80
N: 1448805.94
E: 3113371.34
61.47 LF 24" RCP @ 0.50%
STORM DRAIN 4-4B
SEE THIS SHEET - RIGHT
STORM DRAIN 4-4A
SEE THIS SHEET - MIDDLE
SANITARY LINE A
SEE SHEET C 610
PROPOSED 8"
PVC WATER
PROPOSED 8"
PVC WATER
10' TR
A
I
L
STORM DRAIN 6
SEE SHEET C 626
PROPOSED
STORMTECH
CHAMBERS
26.20 LF 8" HDPE @ 0.50%
21.52 LF 8" HDPE @ 0.50%
BEND 4-5 w CO
STA 13+08.67
N: 1448973.65
E: 3113454.76
BEND 4-6
STA 13+30.19
N: 1448988.79
E: 3113470.05
23.20 LF 8" HDPE @ 0.50%
BUILDING 3
BUILDING 4 BUILDING 5
STORM JOINTS NEED TO BE
WRAPPED 10 FT ON EITHER
SIDE OF CROSSING
RD 4 TEE 2
STA 11+65.97
N: 1448857.28
E: 3113428.50
11.17 LF 18" HDPE @ 0.50%
TR DRAIN TEE 3
STA 11+77.14
N: 1448868.45
E: 3113428.50
16.18 LF 18" HDPE @ 0.50%
RD 4 TEE 4
STA 11+93.32
N: 1448884.63
E: 3113428.51
7.53 LF
18" HDPE
@ 0.50%
RD 4 TEE 6
STA 12+08.81
N: 1448900.12
E: 3113428.52
27.20 LF 18" HDPE @ 0.50%
RD 4 TEE 7
STA 12+36.00
N: 1448927.32
E: 3113428.53
46.46 LF 18" HDPE @ 0.50%
35.55 LF
12" HDPE
@ 0.50%
BLDG CONN. TEE 5
STA 12+00.84
N: 1448892.16
E: 3113428.51
7.96 LF 18" HDPE @ 0.50%
BEND 4-7 w CO
STA 13+53.39
N: 1449011.99
E: 3113470.07
7.98 LF 8" HDPE @ 0.50%
BEND 4-8
STA 13+61.37
N: 1449017.63
E: 3113475.71
8.53 LF 8" HDPE @ 0.50%INLET 4-9
STA 13+69.90
N: 1449017.62
E: 3113484.24
W STUART ST
5000
5005
5010
5015
5020
5025
5030
5000
5005
5010
5015
5020
5025
5030
9+50 10+00 11+00 12+00 13+00 14+00 14+50
PROPOSED
GROUND
EXISTING
GROUNDSTMH 4-4STA 12+82.47RIM 5015.5±INV. IN 5012.50 (E)INV. IN 5012.50 (N)INV. IN 5012.50 (W)INV. OUT 5012.50 (S)13.92 LF
18" HDPE
@ 0.50%BASIN 4-3 (w WEIR)STA 11+37.27RIM 5016.3±INV. IN 5011.77 (N)INV. IN 5012.25 (E)INV. IN 5012.33 (E)INV. OUT 5011.77 (W)61.47 LF 24" RCP @ 0.50%
75.80 LF 24" RCP @ 0.50%STMH 4-2STA 10+75.80RIM 5015.9±INV. IN 5011.46 (E)INV. OUT 5011.46 (S)FES 4-1STA 10+00.00RIM 5013.5±INV. IN 5011.08 (N)26.20 LF 8" HDPE @ 0.50%
30" WATER
STA.=13+35.07
TOP=5008.36
8" PVC WATER
STA.=11+02.96
TOP=5009.85 BEND 4-5 w COSTA 13+08.67INV. 5012.63 (NE)INV. 5012.63 (W)21.52 LF 8" HDPE @ 0.50%
23.20 LF 8" HDPE @ 0.50%BEND 4-7 w COSTA 13+53.39INV. 5012.85 (NE)INV. 5012.85 (S)PRIVATE
100-YR
HGL BEND 4-6STA 13+30.19INV. 5012.73 (N)INV. 5012.73 (SW)18" MIN.RD 4 TEE 1STA 11+51.18RIM 5013.6±INV. IN 5011.84 (N)INV. IN 5012.26 (W)INV. OUT 5011.84 (S)TR DRAIN TEE 3STA 11+77.14RIM 5013.7±INV. IN 5011.97 (N)INV. IN 5012.39 (W)INV. OUT 5011.97 (S)RD 4 TEE 4STA 11+93.32RIM 5013.8±INV. IN 5012.05 (N)INV. IN 5013.38 (W)INV. OUT 5012.05 (S)RD 4 TEE 7STA 12+36.00RIM 5014.0±INV. IN 5012.26 (N)INV. IN 5013.43 (W)INV. OUT 5012.26 (S)RD 4 TEE 6STA 12+08.81RIM 5013.9±INV. IN 5012.13 (N)INV. IN 5013.29 (W)INV. OUT 5012.13 (S)RD 4 TEE 2STA 11+65.97RIM 5013.7±INV. IN 5011.91 (N)INV. IN 5013.08 (W)INV. OUT 5011.91 (S)BLDG CONN. TEE 5STA 12+00.84RIM 5013.8±INV. IN 5012.09 (N)INV. IN 5012.59 (W)INV. OUT 5012.09 (S)EEEEESSWFFF
T
TEWW EE E E
SSEFDC
FDCFDC
W
GGGG G G G GG G G G
VAULT
ELEC
G
IRNYLOPLAST
DO NOT POLLUTE DRAINS TO WATERWAYS
H2O
TRAFFIC
VAULTT SVAULT
ELEC
VAULT
ELEC
VAULT
ELEC
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
ELEC
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
EEEEEETTTTTGGGGGGGGEEEEE30" W30" W 30" W 30" W 30" W 30" W 30" W
PROPOSED
GAS
143.18 LF 12" HDPE @ 0.50%
BEND 4-4.3
STA 12+01.45
N: 1448981.69
E: 3113230.05
19.64 LF 12" HDPE @ 0.50%
BEND 4-4.5
STA 12+38.22
N: 1449012.73
E: 3113216.1913.31 LF
12" HDPE
@ 0.50%
INLET 4-4.7
STA 12+87.08
N: 1449012.95
E: 3113167.33
STMH 4-4
STA 10+00.00
N: 1448973.78
E: 3113428.56
EXISTING 30"
WATER
SANITARY LINE A
SEE SHEET C 610
PROPOSED 8"
PVC WATER
STORM DRAIN 4-4A
SEE THIS SHEET - MIDDLE
STORM DRAIN 4
SEE THIS SHEET - LEFT
SANITARY LINE A2
SEE SHEET C 610
BUILDING 2
BUILDING 3
BUILDING 1
9.94 LF 12" HDPE @ 0.50%
BEND 4-4.2 w CO
STA 11+91.51
N: 1448974.63
E: 3113237.05
48.33 LF
12" HDPE
@ 0.50%
TEE 4-4.1
STA 11+43.18
N: 1448974.42
E: 3113285.38
17.13 LF 12" HDPE @ 0.50%
BEND 4-4.4 w CO
STA 12+18.58
N: 1448998.82
E: 3113230.06
STORM JOINTS NEED TO BE
WRAPPED 10 FT ON EITHER
SIDE OF CROSSING
TEE 4-4.6
STA 12+51.53
N: 1449012.79
E: 3113202.88
35.55 LF
12" HDPE
@ 0.50%
W STUART STSFEGTTTEEEEEEEEEEEESSEFDCWGGGGGGGGEEEGGGGGNYLOPLASTDO NOT POLLUTE DRAINS TO WATERWAYS30" W30" W30" W30" W30" W30" W30" WSTMH 4-4
STA 10+00.00
N: 1448973.78
E: 3113428.56
6.66 LF 15" RCP @ 0.50%
INLET 4-4A
STA 10+00.03
N: 1448980.44
E: 3113428.56
STORM DRAIN 4
SEE THIS SHEET - LEFT
STORM DRAIN 4-4B
SEE THIS SHEET - RIGHT
PROPOSED GAS
PROPOSED
ELECTRIC
PROPOSED 8"
PVC WATER
EXISTING
30" WATER
BUILDING 3
BUILDING 4
BUILDING 5
5000
5005
5010
5015
5020
5025
5030
5000
5005
5010
5015
5020
5025
5030
9+5010+0011+0012+0013+0013+50
PROPOSED
GROUND
EXISTING
GROUND STMH 4-4STA 10+00.00RIM 5015.5±INV. IN 5012.50 (E)INV. IN 5012.50 (N)INV. IN 5012.50 (W)INV. OUT 5012.50 (S)143.18 LF 12" HDPE @ 0.50%BEND 4-4.3STA 12+01.45INV. 5013.51 (N)INV. 5013.51 (SE)19.64 LF
12" HDPE
@ 0.50%BEND 4-4.5STA 12+38.22INV. 5013.70 (W)INV. 5013.70 (SE)INLET 4-4.7STA 12+87.08RIM 5016.1±INV. OUT 5013.95 (E)30" WATER
STA.=12+13.58
TOP=5007.42TEE 4-4.6STA 12+51.53INV. 5014.02 (N)INV. 5013.77 (W)INV. 5013.77 (E)13.31 LF
12" HDPE
@ 0.50%
35.55 LF
12" HDPE
@ 0.50%BEND 4-4.4 w COSTA 12+18.58INV. 5013.60 (NW)INV. 5013.60 (S)17.13 LF
12" HDPE
@ 0.50%
PRIVATE
48.33 LF
12" HDPE
@ 0.50%TEE 4-4.1STA 11+43.18INV. 5013.22 (W)INV. 5013.22 (N)INV. 5013.22 (E)BEND 4-4.2 w COSTA 11+91.51INV. 5013.46 (NW)INV. 5013.46 (E)5000
5005
5010
5015
5020
5025
5030
5000
5005
5010
5015
5020
5025
5030
9+50 10+00 11+00STMH 4-4STA 10+11.51RIM 5015.5±INV. IN 5012.50 (E)INV. IN 5012.50 (N)INV. IN 5012.50 (W)INV. OUT 5012.50 (S)6.66 LF
15" RCP
@ 0.50%INLET 4-4ASTA 10+18.17RIM 5015.3±INV. OUT 5012.53 (S)PROPOSED
GROUND
EXISTING
GROUND
PRIVATE
100-YR
HGL
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
C 624PLAN & PROFILESTORM DRAINS 4, 4-4A, & 4-436
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
( IN FEET )
1 inch = ft.
Feet05050
50
100 150
PROFILE SCALE:
STORM DRAIN 4
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
NOTES:
W
EXISTING SANITARY SEWER SS
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPOSED LOT LINE
PROJECT BOUNDARY
EXISTING RIGHT OF WAY
EXISTING STORM SEWER
EASEMENT LINE
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES.
3.PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND
STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF
FLARED END SECTIONS.
4.ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND
INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY CITY OF
FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE
R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE
'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443
FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE).
5.CONTRACTOR SHALL CONFIRM THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR
THEIR PROPOSED METHODS OF INSTALLATION (i.e., WITHIN PRE-CASTER'S
TOLERANCES, ETC.).
6.CONTRACTOR SHALL DEFLECT SERVICE LINES TO AVOID STORM DRAIN LINES BY 18"
VERTICALLY.
PROPOSED RIGHT OF WAY
INLET SUMMARY TABLE
DESIGN
POINT
DESIGN INLET
LABEL INLET TYPE INLET SIZE
A2 INLET 2-5 Area Inlet 2' X 15'
B1 INLET 3-4 Nyoplast 30 in.30"
B2 INLET 1-3 Nyloplast 3'X3' (36"
basin)3' X 3'
B3 INLET 1-4 Nyloplast 3'X3' (36"
basin)3' X 3'
B6 INLET 1-9.5 Type R 5'
B7 INLET 1-9.1 Type R 5'
B9 INLET 1-5.1 Type R 5'
B10 INLET 1-6.3 Type R 5'
D3 INLET 6-2 Type R 5'
D5 INLET 4-4A Nyloplast 3'X3' (30"
basin)3' X 3'
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
PROFILE SCALE:
STORM DRAIN 4-4A STORM DRAIN 4-4
PROFILE SCALE:
NORTH NORTHNORTH
STORM 4
STORM 4-4B
STORM 4-4A
E
E
E
E
E
E
G G
G
G
G
G
G
G GTT
TEWE E
VAULT
ELEC UDUD
E EGG G
UD EE E
E E EE EE E E
SSETFW
G G G G G GG GEEE
E
GGGGGEE E G
NYLOPLAST
DO NOT POLLUTE DRAINS TO WATERWAYS
UDUDUDUDUDUDUDELEC
XX30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W
XXXXXXX30" W
WINNE GRANT R/JOHNELLE S
1821 WALLENBERG DR
ERIKSEN CHRISTOPHER M
1825 WALLENBERG DR
MCCOY JOHN H/SHERRY P
1900 S SHIELDS ST
2
1
"
S
S
2
1
"
S
S
2
1
"
S
S
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBSTMH 5-6
STA 17+18.99
N: 1448744.40
E: 3113441.50
STMH 5-5
STA 15+30.02
N: 1448824.98
E: 3113612.44
STMH 5-4
STA 13+57.85
N: 1448853.68
E: 3113782.20
OUTLET 5-7
STA 18+18.38
N: 1448717.70
E: 3113345.77
STMH 5-2
STA 10+80.18
N: 1448859.30
E: 3114045.64
STMH 5-3
STA 11+02.44
N: 1448838.71
E: 3114037.16
FES 5-1
STA 10+00.00
N: 1448864.84
E: 3114125.62
22.27 LF
18" HDPE
@ 0.60%
255.40 LF 18" HDPE @ 1.05
%
172.17 LF 1
8
"
H
D
P
E
@
0
.
5
0
%
188.9
8
L
F
1
8
"
H
D
P
E
@
0.
5
0
%
99.39 L
F
1
8
"
H
D
P
E
@
0
.
5
0
%
PROPOSED 2'
CONCRETE PAN CANAL IMPORTATIONSPRI
N
G
C
R
E
E
K
STORM DRAIN 4
SEE SHEET C 624
STORM DRAIN 4-4A
SEE SHEET C 624
STORM DRAIN 4-4B
SEE SHEET C 624
STORM DRAIN 2
SEE SHEET C 623
STORM DRAIN 3
SEE SHEET C 623
EXISTING 30"
WATERPROPOSED
ELECTRIC
PROPOSED
GAS
PROPOSED 8'
PVC WATER
SP
R
I
N
G
C
R
E
E
K
80.18 LF
24" RCP
@ 0.50%
UNDERDRAIN
SEE SHEET C 626
STORM DRAIN 5-2
SEE THIS SHEET-RIGHT
PROPOSED
FIRE HYDRANT
SANITARY LINE A
SEE SHEET C 610
BUILDING 3 BUILDING 4 BUILDING 5
BUILDING 1
4995
5000
5005
5010
5015
5020
5025
5030
4995
5000
5005
5010
5015
5020
5025
5030
9+5010+0011+0012+0013+0014+0015+0016+0017+0018+0018+50
22.27 LF
18" HDPE
@ 0.60%
255.40 LF
18" HDPE
@ 1.05%
172.17 LF
18" HDPE
@ 0.50%188.98 LF
18" HDPE
@ 0.50%
99.39 LF
18" HDPE
@ 0.50%STMH 5-6STA 17+18.99RIM 5014.8±INV. IN 5010.41 (W)INV. OUT 5010.41 (NE)STMH 5-5STA 15+30.02RIM 5014.9±INV. IN 5009.47 (SW)INV. OUT 5009.47 (E)STMH 5-4STA 13+57.85RIM 5014.6±INV. IN 5008.61 (W)INV. OUT 5008.61 (E)OUTLET 5-7STA 18+18.38RIM 5013.4±INV. OUT 5010.91 (E)STMH 5-2STA 10+80.18RIM 5010.5±INV. IN 5005.78 (S)INV. IN 5005.78 (W)INV. OUT 5004.87 (E)FES 5-1STA 10+00.00RIM 5006.3±INV. IN 5004.47 (W)EXISTING
GROUND
PROPOSED
GROUND
80.18 LF
24" RCP
@ 0.50%STMH 5-3STA 11+02.44RIM 5011.5±INV. IN 5005.91 (W)INV. OUT 5005.91 (N)PRIVATE
2-YR HISTORIC
RELEASE UDUDUDUDUDUDUDUDXX30" W 30" W
XXX30" W
BBBBBBBBBBBBBBBBBBBBBBBBBPROPOSED 2'
CONCRETE PAN CANAL IMPORTATIONSTORM DRAIN 2
SEE SHEET C 623
STORM DRAIN 3
SEE SHEET C 623
29.50 LF
15" HDPE
@ 3.30%
STMH 5-2
STA 10+00.00
N: 1448859.30
E: 3114045.64
OUTLET 5-2.1
STA 10+29.50
N: 1448849.58
E: 3114017.78
SP
R
I
N
G
C
R
E
E
K
UNDERDRAIN
SEE SHEET C 626
STORM DRAIN 5
SEE THIS SHEET-LEFT
4995
5000
5005
5010
5015
5020
5025
5030
4995
5000
5005
5010
5015
5020
5025
5030
9+5010+0011+00 STMH 5-2STA 10+00.00RIM 5010.5±INV. IN 5005.78 (S)INV. IN 5005.78 (W)INV. OUT 5004.87 (E)29.50 LF
15" HDPE
@ 3.30%OUTLET 5-2.1STA 10+29.50RIM 5009.5±INV. OUT 5006.75 (E)EXISTING
GROUND
PROPOSED
GROUND
PRIVATE
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
C 625PLAN & PROFILESTORM DRAINS 5 & 5-237
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
NORTH
( IN FEET )
1 inch = ft.
Feet05050
50
100 150
PROFILE SCALE:
STORM DRAIN 5
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
NOTES:
W
EXISTING SANITARY SEWER SS
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPOSED LOT LINE
PROJECT BOUNDARY
EXISTING RIGHT OF WAY
EXISTING STORM SEWER
EASEMENT LINE
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES.
3.PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND
STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF
FLARED END SECTIONS.
4.ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND
INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY CITY OF
FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE
R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE
'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443
FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE).
5.CONTRACTOR SHALL CONFIRM THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR
THEIR PROPOSED METHODS OF INSTALLATION (i.e., WITHIN PRE-CASTER'S
TOLERANCES, ETC.).
6.CONTRACTOR SHALL DEFLECT SERVICE LINES TO AVOID STORM DRAIN LINES BY 18"
VERTICALLY.
PROPOSED RIGHT OF WAY
INLET SUMMARY TABLE
DESIGN
POINT
DESIGN INLET
LABEL INLET TYPE INLET SIZE
A2 INLET 2-5 Area Inlet 2' X 15'
B1 INLET 3-4 Nyoplast 30 in.30"
B2 INLET 1-3 Nyloplast 3'X3' (36"
basin)3' X 3'
B3 INLET 1-4 Nyloplast 3'X3' (36"
basin)3' X 3'
B6 INLET 1-9.5 Type R 5'
B7 INLET 1-9.1 Type R 5'
B9 INLET 1-5.1 Type R 5'
B10 INLET 1-6.3 Type R 5'
D3 INLET 6-2 Type R 5'
D5 INLET 4-4A Nyloplast 3'X3' (30"
basin)3' X 3'
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
STORM
DRAIN 5
STORM DRAIN 5-2
PROFILE SCALE:
STORM DRAIN 5-2
SEEEET
SWWW
WWS
SUD
UD
UD
UDEGGG G G G GW
EE18" SSWW S
FDCS SSFSF
F F
SF F
SWNYLOPLASTDO NOT POLLUTE DRAINS TO WATERWAYSNYLOPLASTDO NOT POLL
U
T
E
D
R
A
I
N
S
T
O
W
A
T
E
R
W
A
Y
S
EEEEEEEW MHSS18" SS18" SS18" SS21" SS21" SS21" SS21" SSUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMHXX30" W30" W30" W30" WX
X
X
X
X
X
X
X
X
X
X
X X
X
30" W21" SS 21" SS
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
BB BBB
B
B
B
BB
B
BB
B
B
B
B
B
B BBBBB
B
B
B
BBB
B
B
B
B BBB
B BB
B
B
B
B
B BB
B BB
XXX
B
B BBB
B
B
B
B
X
X
X
X
X
X
PROPOSED 2'
CONCRETE PAN
CANAL IMPORT
A
T
I
O
N
STORM DRAIN 2
SEE SHEET C 623
STORM DRAIN 3
SEE SHEET C 623
EXISTING 30"
WATER SPRING CREEKSTORM DRAIN 5-2
SEE SHEET C 625
STORM DRAIN 5
SEE SHEET C 625
SANITARY LINE C
SEE SHEET C 612
PROPOSED 8"
PVC WATER
EXISTING 18"
SANITARY
EXISTING 21"
SANITARY
STORM DRAIN 1
SEE SHEET C 620
48'
SANITARY
SEWER
EASEMENT
WALL
E
N
B
E
R
G
D
R
47.44 LF 6" HDPE @ 0.20%
RG UD BASIN 2
STA 10+47.44
N: 1449016.23
E: 3114055.00
189.97 LF 4" HDPE @ 0.20%
RG UD CO 3
STA 12+37.41
N: 1449184.94
E: 3113981.90
RG UD PIPE END 1
STA 10+00.00
N: 1449029.22
E: 3114100.63
PROPOSED
RAIN GARDEN
BUILDING 14 BUILDING 13 BUILDING 12 BUILDING 11 BUILDING 10 BUILDING 9
4995
5000
5005
5010
5015
5020
5025
5030
4995
5000
5005
5010
5015
5020
5025
5030
9+5010+0011+0012+0013+00
EXISTING
GROUND
PROPOSED
GROUND RG UD PIPE END 1STA 10+00.00RIM 5006.5±INV. IN 5005.86 (W)47.44 LF
6" HDPE
@ 0.20%RG UD BASIN 2STA 10+47.44RIM 5010.6±INV. IN 5005.95 (NW)INV. OUT 5005.95 (E)189.97 LF
4" HDPE
@ 0.20%RG UD CO 3STA 12+37.41RIM 5008.6±INV. OUT 5006.33 (S)PROPOSED
SUBGRADEEGGGGGGFVAULTELECEEEEWWEEEEEESSFDCGGGGGIRIRT SH2OTRAFFICVAULTT SVAULTELECCONTROLIRRCONTROLIRRELECCONTROLIRRCONTROLIRREETGGGGEEEEEEEEEGGGG30" W30" W30" W30" W30" W36" W 36" W
36" WD/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /30" W30" W30" W30" W30" W30" WSTSTSTSTSSSSSSSSSSSSTORM DRAIN 4
SEE SHEET C 624STORM DRAIN 4-4B
SEE SHEET C 624
INLET 6-2
STA 11+07.91
N: 1448843.05
E: 3113202.86
107.91 LF 18" RCP @ 0.20%
FES 6-1
STA 10+00.00
N: 1448735.14
E: 3113201.88
S SHIELDS STREET
SANITARY LINE A
SEE SHEET C 610
BUILDING 1
STORM JOINTS TO
BE WRAPPED 10 FT
ON EITHER SIDE OF
CROSSING
BUILDING 1 ROOF DRAIN PLAN
SEE SHEET C 607-C 608
5000
5005
5010
5015
5020
5025
5030
5035
5000
5005
5010
5015
5020
5025
5030
5035
9+5010+0011+0012+00 INLET 6-2STA 11+07.91RIM 5016.3±INV. IN 5013.04 (NW)INV. IN 5013.04 (E)INV. OUT 5013.04 (S)107.91 LF 18" RCP @ 0.20%FES 6-1STA 10+00.00RIM 5015.2±INV. IN 5012.83 (N)EXISTING
GROUND
PROPOSED
GROUND
8" PVC WATER
STA.=10+80.89
TOP=5011.24
PRIVATE
100-YR
HGL
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
C 626PLAN & PROFILESTORM DRAIN 6 & UNDERDRAIN38
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
NORTH
( IN FEET )
1 inch = ft.
Feet05050
50
100 150
PROFILE SCALE:
UNDERDRAIN
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
NOTES:
W
EXISTING SANITARY SEWER SS
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPOSED LOT LINE
PROJECT BOUNDARY
EXISTING RIGHT OF WAY
EXISTING STORM SEWER
EASEMENT LINE
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES.
3.PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND
STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF
FLARED END SECTIONS.
4.ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND
INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY CITY OF
FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE
R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE
'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443
FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE).
5.CONTRACTOR SHALL CONFIRM THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR
THEIR PROPOSED METHODS OF INSTALLATION (i.e., WITHIN PRE-CASTER'S
TOLERANCES, ETC.).
6.CONTRACTOR SHALL DEFLECT SERVICE LINES TO AVOID STORM DRAIN LINES BY 18"
VERTICALLY.
PROPOSED RIGHT OF WAY
INLET SUMMARY TABLE
DESIGN
POINT
DESIGN INLET
LABEL INLET TYPE INLET SIZE
A2 INLET 2-5 Area Inlet 2' X 15'
B1 INLET 3-4 Nyoplast 30 in.30"
B2 INLET 1-3 Nyloplast 3'X3' (36"
basin)3' X 3'
B3 INLET 1-4 Nyloplast 3'X3' (36"
basin)3' X 3'
B6 INLET 1-9.5 Type R 5'
B7 INLET 1-9.1 Type R 5'
B9 INLET 1-5.1 Type R 5'
B10 INLET 1-6.3 Type R 5'
D3 INLET 6-2 Type R 5'
D5 INLET 4-4A Nyloplast 3'X3' (30"
basin)3' X 3'
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
UNDERDRAIN
STORM DRAIN 6
PROFILE SCALE:
STORM
DRAIN 6
CABLE
F.O.
MH
TTTTTTTTTT5015 (NAVD88)
A
M
5
0
1
4
(
N
A
V
D
8
8
)5014
(NAVD88
)5013 (NAVD88)5011 (NAVD88)5010 (NAVD88)5008 (NAVD88)179
178
177
176
175
174
173
172171170169168
5010 (NAV
D
8
8
)
5011 (NAVD
8
8
)5012 (NAVD88)5013 (NAVD88)S
S
D
F.O.
MH
MM
MH
/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /STSTSTSTSTSTWINNE GRANT R/JOHNELLE S
1821 WALLENBERG DR
ERIKSEN CHRISTOPHER M
1825 WALLENBERG DR
MCCOY JOHN H/SHERRY P
1900 S SHIELDS ST
HILL POND CONDOMINIUMS
STA: 83 ELEV: 50
0
9
.
1
7
STA: 200 ELEV
:
5
0
0
9
.
5
7
STA: 319 EL
E
V
:
5
0
1
0
.
0
5
STA: 3
7
2
E
L
E
V
:
5
0
1
0
.
1
5
STA: 4
2
3
E
L
E
V:
5
0
1
0.
3
3
STA: 5
2
2
E
L
E
V
:
5
0
1
0.
6
2
STA: 720 EL
E
V
:
5
0
1
1
.
1
5
STA: 80
5
E
L
E
V
:
5
0
1
1
.
4
2STA: 905 ELEV: 5011.89STA: 983 ELEV: 5012.08STA: 1075 ELEV: 5012.31STA: 1136 ELEV: 5012.53SSSSSSSSSSSSSSh-a1
h-b2
h-b1
h-c1
h-d1
2.53 ac.
H-B1
1.01 ac.
H-A1
3.92 ac.
H-B2
0.74 ac.
H-C1
h-a20.16 ac.
H-A2
0.17 ac.
H-D1
os2
os3
1.80 ac.
OS2
0.47 ac.
OS3
0.44 ac.
H-B3
h-b3
h-c2
5.47 ac.
H-C2
3.38 ac.
H-E1
1.38 ac.
H-E2
h-e1
h-e2
0.48 ac.
OS1
os1
0.04 ac.
H-F1
h-f1
h-f2
0.18 ac.
H-F2
S SHIELDS ST.HOBBIT ST.WALLENBERG DR.FEMA 100-YR
HIGH RISK
FLOOD FRINGE
CITY OF FORT COLLINS
100-YR FLOODPLAIN
EXIST
I
N
G
S
P
R
I
N
G
C
R
E
E
K
T
R
A
I
L
SPRI
N
G
C
R
E
E
KEXISTING SIDEWALKEXISTING 8' TRAILCANAL IMPORTATIONWINNE GRANT
R/JOHNELLE S
1821 WALLENBERG
DR
ERIKSEN
CHRISTOPHER M
1825
WALLENBERG
DR
MCCOY JOHN H/SHERRY P
1900 S SHIELDS ST
HILL POND CONDOMINIUMS
FEMA XSEC #22186
5014.4 FT (NAVD 88)
FEMA 100-YR
FLOODWAY
CITY OF FORT
COLLINS 100-YR
FLOODWAY
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
LEGEND:
NORTH
( IN FEET )
0
1 INCH = 50 FEET
50 50 100 150
C 700EXHIBITHISTORIC DRAINAGE 39
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
INTERMILL LAND SURVEYING, INC.NORTHERN ENGINEERING SERVICES, INC.
COMPANY PROJECT NO. P-11-6963 COMPANY PROJECT NO. 838-016
DATE: APRIL 2011 DATE: JULY 2015
KING SURVEYORS
COMPANY PROJECT NO. 20190806
DATE: JANUARY 2020
PROJECT DATUM: NAVD88
BENCHMARK 29-92 APPROXIMATE 300 FEET SOUTH OF WEST PROSPECT ROAD AND
SHIELDS STREET, ON THE NORTH END OF THE WEST BRIDGE PARAPET WALL.
ELEVATION: 5025.67
BENCHMARK 28-92 SOUTHWEST CORNER OF WEST PROSPECT ROAD AND CENTER
AVENUE, ON A WATER VALVE PIT.
ELEVATION: 5010.65
PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM.
SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED DATUM (PRIOR
CITY OF FORT COLLINS DATUM) FOR THEIR VERTICAL DATUMS.
IF NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) IS REQUIRED
FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29
UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) = NAVD88 - 3.17'.
BASIS OF BEARINGS
WEST LINE OF THE NORTHWEST QUARTER OF SECTION 23 AS BEARING NORTH 00° 01'
50" EAST (ASSUMED BEARING), AND MONUMENTED AS SHOWN ON DRAWING.
PROPOSED CONTOUR
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROPOSED INLET
A
DESIGN POINT
FLOW ARROW
DRAINAGE BASIN LABEL
DRAINAGE BASIN BOUNDARY
PROPOSED SWALE SECTION
11
NOTES:
1.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION
2.ALL ELEVATIONS DEPICTED IN PLAN VIEW AND BENCHMARKS LISTED HEREON ARE
PER THE CITY OF FORT COLLINS VERTICAL CONTROL DATUM (NAVD 88).
3.NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE FLOODWAY,
WHETHER TEMPORARY (DURING CONSTRUCTION) OR PERMANENT. LANDSCAPING
SHALL ALSO MEET THE REQUIREMENTS FOR NO RISE IN THE FLOODWAY.
4.REFER TO THE FINAL DRAINAGE AND EROSION CONTROL REPORT FOR THE QUARRY
BY WATERMARK, DATED SEPTEMBER 1, 2021 BY NORTHERN ENGINEERING FOR
ADDITIONAL INFORMATION.
5.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE CITYREGULATED, 100YEAR
CANAL IMPORTATION FLOODPLAIN/FLOODWAY AS WELL AS THE FEMA REGULATED
SPRING CREEK 100YEAR FLOODPLAIN/FLOODWAY. ANY DEVELOPMENT WITHIN THE
FLOODPLAIN MUST COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF CITY
MUNICIPAL CODE. THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM
THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE PERMIT FEES
PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES,
GRADING, FILL, DETENTION PONDS, BIKE PATHS, PARKING LOTS, UTILITIES,
LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE CITY OF FORT
COLLINS FLOODPLAIN LIMITS AS DELINEATED ON THE FINAL SUBDIVISION PLAT
6.ANY CONSTRUCTION ACTIVITIES, NONSTRUCTURAL DEVELOPMENT (BRIDGES,
SIDEWALKS, CULVERTS, VEGETATION, CURBCUTS, GRADING, ETC.) IN THE
REGULATORY FLOODWAY MUST BE PRECEDED BY A NORISE CERTIFICATION, WHICH
MUST BE PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF
COLORADO.
7.NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE FLOODWAY,
WHETHER TEMPORARY (DURING CONSTRUCTION) OR PERMANENT.
8.ANY PEDESTRIAN BRIDGES IN THE FLOODWAY THAT ARE NOT ABLE TO PASS THE 100
YEAR FLOW ARE REQUIRED TO BE “BREAKAWAY” AND TETHERED.
A
CROSS-SECTION (CSL)XS#: 2446
FIELD SURVEY BY:
CORRECTED EFFECTIVE BASE FLOOD
ELEVATION (BFE)
5003 (NAVD88)ELEVATION NAVD 88
BENCHMARK
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
FOR DRAINAGE REVIEW ONLY
NOT FOR CONSTRUCTION
CABLEF.O.
T
MH
B M
TTTTTTA
M
AL179
178
177
176
175
174
173
172171170169168/ / / / / / / // / / / / / / /
W WWWSS
SSUDUDS
S
D
F.O.
D
MH
MM
MH
/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /STSTSTSTSSSSSSSSSSUDUDUD
FDC
FDCFDC FDC
FDCFDCFDCFDC
NYLOPLAST
DO NOT POLLUTE DRAINS TO WATERWAYS
NYLOPLAST
DO NOT POLLUTE DRAINS TO WATERWAYS
NYLOPLAST
DO NOT POLLUTE DRAINS TO WATERWAYS / / / / / / / // / / / / / / /
W WWWSS
SSUDUDBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBXXXXTRACT B
TRACT A
RAIN GARDEN A
EXISTING DRAINAGE
DITCH (DITCH C)
DETENTION
POND 2
100-YR WSEL =
5014.91
1.32 ac.
A1
0.98 ac.
D1
0.22 ac.
D2
0.61 ac.
B1
1.75 ac.
A2
0.70 ac.
B2
0.64 ac.
D7
0.48 ac.
B5
0.29 ac.
B4
0.21 ac.
B10
0.11 ac.
C1
0.16 ac.
C2
0.79 ac.
B7
0.47 ac.
OS3
3.38 ac.
E1
1.38 ac.
E2
0.48 ac.
OS1
1.80 ac.
OS2
0.18 ac.
F2
0.04 ac.
F1
d7
d1
a1
b1
b2
b4
b5
b6
b7
b3
c1
d2
os2
os3
e1
e2
os1
c2
CITY OF FORT COLLINS
100-YR FLOODWAY
S SHIELDS ST.HOBBIT ST.WALLENBERG DR.CITY OF FORT COLLINS
100-YR FLOODPLAIN
EXIST
I
N
G
S
P
R
I
N
G
C
R
E
E
K
T
R
A
I
L
SPRI
N
G
C
R
E
E
KEXISTING SIDEWALKCANAL IMPORTATIONWINNE GRANT R/JOHNELLE S
1821 WALLENBERG DR
ERIKSEN CHRISTOPHER M
1825 WALLENBERG DR
MCCOY JOHN H/SHERRY P
1900 S SHIELDS ST
HILL POND CONDOMINIUMS
f2
f1
PROPOSED
STORM DRAIN
PROPOSED
STORM DRAIN
PROPOSED
OUTFALL PIPE
PROPOSED
STORM DRAIN
PROPOSED OUTLET
STRUCTURE 5:15:15:15:112:1a2
PROPOSED
STORM DRAIN
DETENTION
POND 1
100-YR WSEL =
5011.37
1.05 ac.
D5
PROPOSED
STORM DRAIN
PROPOSED
STORM DRAIN 0.21 ac.
D3
0.77 ac.
D4
0.07 ac.
D6
d4
d3
d5
d6
PROPOSED OUTLET
STRUCTURE
PROPOSED
STORM
CHAMBERS 2
PROPOSED
STORM
CHAMBERS 1
FEMA XSEC #22186
5014.4 FT (NAVD 88)
FEMA 100-YR
FLOODWAY
CITY OF FORT
COLLINS 100-YR
FLOODWAY
PROPOSED
STORM DRAIN
PROPOSED
STORM DRAIN
BLDG 6 BLDG 7
BLDG 2
BLDG 3
BLDG 4 BLDG 5 BLDG 8
BLDG 17
BLDG 16
BLDG 15
BLDG 14
BLDG 13
BLDG 12
BLDG 11
BLDG 10
BLDG 9
POND
OVERFLOW PATH
POND 2 OVERFLOW
CHANNEL TO POND 1 EXISTING 8' TRAILW PROSPECT RD.
W STUART ST.
BLDG 1
b8
0.43 ac.
B8
0.87 ac.
B6
FEMA 100-YR
HIGH RISK
FLOOD FRINGE
PROPOSED
STORM DRAIN
0.46 ac.
B9
b9
b10
2.31 ac.
B3
INLET 1-4
INLET 1-3
INLET 1-5.1
INLET 1-6.3
INLET 1-9.1
INLET 1-9.4
INLET 4-4A
INLET 6-2
INLET 2-5
SIDEWALK
CHASE D4
PROPOSED
TRENCH DRAIN
BLDG 18
ASHLAR DRW STUART ST
INTERMILL LAND SURVEYING, INC.NORTHERN ENGINEERING SERVICES, INC.
COMPANY PROJECT NO. P-11-6963 COMPANY PROJECT NO. 838-016
DATE: APRIL 2011 DATE: JULY 2015
KING SURVEYORS
COMPANY PROJECT NO. 20190806
DATE: JANUARY 2020
PROJECT DATUM: NAVD88
BENCHMARK 29-92 APPROXIMATE 300 FEET SOUTH OF WEST PROSPECT ROAD AND
SHIELDS STREET, ON THE NORTH END OF THE WEST BRIDGE PARAPET WALL.
ELEVATION: 5025.67
BENCHMARK 28-92 SOUTHWEST CORNER OF WEST PROSPECT ROAD AND CENTER
AVENUE, ON A WATER VALVE PIT.
ELEVATION: 5010.65
PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM.
SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED DATUM (PRIOR
CITY OF FORT COLLINS DATUM) FOR THEIR VERTICAL DATUMS.
IF NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) IS REQUIRED
FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29
UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) = NAVD88 - 3.17'.
BASIS OF BEARINGS
WEST LINE OF THE NORTHWEST QUARTER OF SECTION 23 AS BEARING NORTH 00° 01'
50" EAST (ASSUMED BEARING), AND MONUMENTED AS SHOWN ON DRAWING.
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
PROPOSED CONTOUR
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROPOSED INLET
A
DESIGN POINT
FLOW ARROW
DRAINAGE BASIN LABEL
DRAINAGE BASIN BOUNDARY
PROPOSED SWALE SECTION
11
NOTES:
A
LEGEND:
NORTH
( IN FEET )
0
1 INCH = 80 FEET
80 80 160 240
C 701DRAINAGE EXHIBIT40
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
CROSS-SECTION (CSL)XS#: 2446
FIELD SURVEY BY:
CORRECTED EFFECTIVE BASE FLOOD
ELEVATION (BFE)
5003 (NAVD88)ELEVATION NAVD 88
BENCHMARK
1.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION
2.ALL ELEVATIONS DEPICTED IN PLAN VIEW AND BENCHMARKS LISTED HEREON ARE
PER THE CITY OF FORT COLLINS VERTICAL CONTROL DATUM (NAVD 88).
3.NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE FLOODWAY,
WHETHER TEMPORARY (DURING CONSTRUCTION) OR PERMANENT. LANDSCAPING
SHALL ALSO MEET THE REQUIREMENTS FOR NO RISE IN THE FLOODWAY.
4.REFER TO THE FINAL DRAINAGE AND EROSION CONTROL REPORT FOR THE QUARRY
BY WATERMARK, DATED SEPTEMBER 1, 2021 BY NORTHERN ENGINEERING FOR
ADDITIONAL INFORMATION.
5.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE CITYREGULATED, 100YEAR
CANAL IMPORTATION FLOODPLAIN/FLOODWAY AS WELL AS THE FEMA REGULATED
SPRING CREEK 100YEAR FLOODPLAIN/FLOODWAY. ANY DEVELOPMENT WITHIN THE
FLOODPLAIN MUST COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF CITY
MUNICIPAL CODE. THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM
THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE PERMIT FEES
PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES,
GRADING, FILL, DETENTION PONDS, BIKE PATHS, PARKING LOTS, UTILITIES,
LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE CITY OF FORT
COLLINS FLOODPLAIN LIMITS AS DELINEATED ON THE FINAL SUBDIVISION PLAT
6.ANY CONSTRUCTION ACTIVITIES, NONSTRUCTURAL DEVELOPMENT (BRIDGES,
SIDEWALKS, CULVERTS, VEGETATION, CURBCUTS, GRADING, ETC.) IN THE
REGULATORY FLOODWAY MUST BE PRECEDED BY A NORISE CERTIFICATION, WHICH
MUST BE PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF
COLORADO.
7.NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE FLOODWAY,
WHETHER TEMPORARY (DURING CONSTRUCTION) OR PERMANENT.
8.ANY PEDESTRIAN BRIDGES IN THE FLOODWAY THAT ARE NOT ABLE TO PASS THE 100
YEAR FLOW ARE REQUIRED TO BE “BREAKAWAY” AND TETHERED.
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
FOR DRAINAGE REVIEW ONLY
NOT FOR CONSTRUCTION
LID Summary per LID Structure
LID ID
Area Weighted %
Impervious Subbasin ID Treatment Type Volume per
UD-BMP (ft3)
Vol. w/20%
Increase per Fort
Collins Manual
(ft3)
Impervious
Area (ft2)
Sq. Ft.Acres
Rain Garden A 318,413 7.31 72%B1 Rain Garden 7,104 8,525 228,508
Stormtech 1 76,238 1.75 77%A2 Stormtech 1,578 1,894 58,703
Stormtech 2 81,341 1.87 58%D5,6,7 Stormtech 1,247 1,496 47,552
Total 475,992 10.93 11,915 334,763
Rational Flow Summary | Developed Basin Flow Rates
BASIN
TOTAL
AREA
(acres)
Tc2
(min)
Tc100
(min)
C2 C100 Q2
(cfs)
Q100
(cfs)
A1 1.32 5.0 5.0 0.27 0.34 1.02 4.47
A2 1.75 5.0 5.0 0.79 0.99 3.94 17.24
B1 0.61 10.7 10.7 0.48 0.60 0.64 2.78
B2 0.70 5.0 5.0 0.69 0.86 1.37 5.95
B3 2.31 5.0 5.0 0.92 1.00 6.07 23.03
B4 0.24 5.0 5.0 1.00 1.00 0.70 2.43
B5 0.48 5.0 5.0 0.65 0.82 0.89 3.92
B6 0.87 5.0 5.0 0.95 1.00 2.35 8.64
B7 0.84 5.0 5.0 0.86 1.00 2.05 8.32
B8 0.43 5.0 5.0 0.75 0.93 0.91 3.94
B9 0.46 5.0 5.0 0.95 1.00 1.24 4.57
B10 0.21 5.2 5.2 0.49 0.61 0.29 1.25
C1 0.11 5.0 5.0 0.25 0.31 0.08 0.33
C2 0.16 5.0 5.0 0.63 0.78 0.29 1.26
D1 0.98 5.0 5.0 0.29 0.37 0.81 3.60
D2 0.22 10.6 10.6 0.25 0.31 0.12 0.51
D3 0.21 5.0 5.0 0.85 1.00 0.52 2.13
D4 0.77 5.0 5.0 0.92 1.00 2.01 7.64
D5 1.05 5.0 5.0 0.91 1.00 2.73 10.49
D6 0.07 5.0 5.0 0.68 0.85 0.13 0.58
D7 0.64 6.1 6.1 0.36 0.45 0.61 2.68
E1 3.38 12.8 12.8 0.16 0.19 1.09 4.53
E2 1.38 8.8 8.8 0.11 0.14 0.36 1.59
F1 0.05 5.0 5.0 0.72 0.90 0.09 0.40
F2 0.18 7.3 7.3 0.62 0.78 0.28 1.21
OS1 0.48 5.0 5.0 0.84 1.00 1.16 4.82
OS2 1.80 9.3 9.3 0.91 1.00 3.77 14.45
OS3 0.87 5.0 5.0 0.86 1.00 2.14 8.69
LID Site Summary - New Impervious Area
Total Area of Current Development 642,773 ft2
Total Impervious Area 385,987 ft2
Total Impervious Area without LID Treatment 51,223 ft2
A1,C,D1-4,E,F
75% Requried Minium Area to be Treated 289,490
Total Treated Area 334,763 ft2
Percent Impervious Treated by LID 86.73%
INLET CAPACITY SUMMARY
Project:1791-001
Calculations By:Cassandra Ungerman
Date:August 27, 2021
Design
Point Design Inlet Label Q2 Q100 Q100 Total Q100 Intercepted Q100 Unintercepted Inlet Type Inlet Size NotesA2INLET 2-5 3.97 17.17 48.60*48.60 0.00 Area Inlet 2' X 15'Captures 100-yr for A2 and Q100 unintercepted for all B basins
B1 INLET 3-4 25.24 n/a n/a n/a Nyoplast 30 in.30"30" basin will capture 2-yr flows(16.83 cfs) + 50% clogging factor
B2 INLET 1-3 1.25 5.33 4.47 0.86 Nyloplast 3'X3' (36" basin)3' X 3'Overflow continues to DP A2
B3 INLET 1-4 6.20 24.03 6.20 17.83 Nyloplast 3'X3' (36" basin)3' X 3'Captures 2-yr flow - Overflow continues to DP A2
B6 INLET 1-9.5 2.35 8.64 2.80 5.84 Type R 5'Captures 2-yr flow w/ 4" ponding - Overflow continues to DP A2
B7 INLET 1-9.1 2.04 7.92 2.80 5.12 Type R 5'Can capture 2-yr w/ 4" ponding - Overflow continues to DP A2
B9 INLET 1-5.1 1.24 4.57 2.80 1.77 Type R 5'Captures 2-yr flow w/ 4" ponding- Overflow continues to DP A2
B10 INLET 1-6.3 0.29 1.25 1.25 0.00 Type R 5'Captures 100-yr flow
D3 INLET 6-2 4.57**2.13 17.79**5.90 11.89 Type R 5'Captures 2-yr flow - Overflow will continue to sidewalk chase
D5 INLET 4-4A 2.75 10.67 10.67 0.00 Nyloplast 3'X3' (30" basin)3' X 3'Captures 100-yr flow w/ ~6" ponding
Notes:*Q100 for Inlet 2-5 (DP A2) includes the Q100 value for A2 (17.24 cfs) AND the sum of the Q100 Intercepted values for basins B1-B10
**Q values for Inlet 6-2 (DP D3) include the Q value for D3 (2.13 cfs) AND the sum of the Q values for basins OS2 and F2
***All landscape area drains shall be minimum 8" Nyloplast dome grate or determined by pipe size. Landscape flows accounted for at the main.
POND SUMMARY TABLE
Pond ID
Tributary Area
(Ac)
Ave Percent
Imperviousness
(%)
100-Yr. Detention
Vol. (Ac-Ft)
100-Yr. Detention
WSEL(Ft)Peak Release (cfs)
Pond 1 8.51 57 1.82 5011.37 0.94
Pond 2 6.33 68 0.83 5014.91 5.15
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
C 800WATER DETAILS41
100 TYPICAL WATER MAIN
106 TYPICAL WATER SERVICE
107 TYPICAL SETTING FOR 1-1/2 IN. AND 2 IN.
WATER METERS
103 TYPICAL SETTING FOR 1-1/2 IN. AND 2 IN.
WATER METERS
102 TYPICAL MAIN LOWERING ANCHOR BLOCKS
101 TYPICAL FIRE HYDRANT
105 TYPICAL WATER MAIN LOWERING
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
6"6"6"6"6"6"6"6"6"6"6"6"6"6"6"6"6"6"6"6"STREET STREET6"
104 TYPICAL TRACER WIRE
WATER LOWERING ELEVATIONS (TOP OF PIPE)
CROSSING 1 2 3 4 D (FT)T (FT)
WATER LOWERING 1 5010.75 5008.93 5008.93 5010.75 2 N/A
WATER LOWERING 2 5010.88 5009.3 5009.3 5010.88 0.67 N/A
WATER LOWERING 3 5009.69 5007.73 5007.73 5009.69 2 N/A
WATER LOWERING 4 5009.25 5008.24 5008.24 5009.25 0.67 N/A
WATER LOWERING 5 5008.62 5007.8 5007.8 5008.62 2 N/A
WATER LOWERING 6 5012.38 5011.24 5011.24 5012.38 1.5 N/A
WATER LOWERING 7 5011.51 5011.01 5011.01 5011.51 2 N/A
6" No-Hub
Bottom Outlet
Closed End
Cap
6" - 90° Bend
6" HDPE STORM
DRIAN
6" PVC Pipe
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
C 801WATER DETAILS42
201 TRAFFIC-RATED CURB STOP INSTALLATION 202 3
4 IN. AND 1 IN. WATER METER 203 3
4 IN. AND 1 IN. WATER METER TRENCH DRAIN DETAIL
NOTE: + Actual Channel length is 81 1
4" to allow for overlap.
204
205 POLYETHYLENE AWWA C-105 WRAP
POLYETHYLENE TUBE
POLYETHYLENE TUBEPIPE
PLASTIC TAPE
PIPE
PIPE
EXCESS MATERIAL SHALL BE
PIPE BARREL, FOLDED ON
TOP OF PIPE AND TAPED IN
MATERIAL ON PIPE PRIOR TO
LOWERING IT INTO TRENCH.
AROUND THE ADJACENT SPIGOT
END AND WRAP WITH TAPE TO HOLD
THE PLASTIC TUBE IN PLACE.
NEATLY DRAWN UP AROUND THE
PLACE TUBE OF 8 MIL POLYETHYLENE
PULL THE TUBE OVER THE LENGTH
OF THE PIPE. TAPE TUBE TO
PIPE AT JOINT. FOLD MATERIAL
MACHINE AREA. INSTALL
AND POLYETHYLENE.
MAKE TAPS BY WRAPPING THREE
THE PIPE TO COVER THE TAPPING
CORPORATION STOP THROUGH THE TAPE
LAYERS OF COMPATIBLE TAPE AROUND
PLACE.
PIPE AND TAPED IN PLACE.
CLEAN MATERIAL THAT WILL
NOT DAMAGE ENCASEMENT.
CAREFULLY BACKFILL WITH
PIPE BARREL, FOLDED ON TOP OF
OVERLAP FIRST TUBE WITH
ADJACENT TUBE AND SECURE WITH
PLASTIC ADHESIVE TAPE. THE
POLYETHYLENE TUBE MATERIAL
COVERING THE PIPE SHALL BE
LOOSE. EXCESS MATERIAL SHALL
BE NEATLY DRAWN UP AROUND THE
POLYETHYLENE TUBE
PLASTIC TAPE
Restraint Calculations
Location Total Restraint
Length
22.5 Degree Bend 10 ft
45 Degree Bend 20 ft
90 Degree Bend 48 ft
Water Lowering 1 76 ft
Water Lowering 2 76 ft
Water Lowering 3 76 ft
Water Lowering 4 76 ft
Water Lowering 5 76 ft
Water Lowering 6 76 ft
Water Lowering 7 76 ft
207 JOINT RESTRAINT TABLE
WATER LOWERING ELEVATIONS (TOP OF PIPE)
CROSSING 1 2 3 4 D (FT)T (FT)
WATER LOWERING 1 5010.75 5008.93 5008.93 5010.75 2 N/A
WATER LOWERING 2 5010.88 5009.3 5009.3 5010.88 0.67 N/A
WATER LOWERING 3 5009.69 5007.73 5007.73 5009.69 2 N/A
WATER LOWERING
4 5009.25 5008.24 5008.24 5009.25 0.67 N/A
WATER LOWERING 5 5008.62 5007.8 5007.8 5008.62 2 N/A
WATER LOWERING 6 5012.38 5011.24 5011.24 5012.38 1.5 N/A
WATER LOWERING 7 5011.51 5011.01 5011.01 5011.51 2 N/A
206 WATER LOWERING TABLE
304
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
C 802DETAILSSANITARY SEWER43
SERVICE WYE CLEANOUT
300 TYPICAL WASTEWATER BEDDING
302 TYPICAL MANHOLE (WASTEWATER)
COMPACTED GRANULAR MATERIAL
CONFORMING TO CDDH #67
LOWER LIMIT OF
TRENCH WALL
SLOPING
INITIAL LIFT *
12 IN. MIN.
PIPE O.D.
4 IN. MIN.
TRENCH WIDTH AS SPECIFIED
IN SECTION 02221
COMPACTED GRANULAR MATERIAL
CONFORMING TO CDDH #67
*
BEDDING REQUIRMENTS
WW-1
ALTERNATE BASE
POURED INVERT
PRECAST MANHOLE BASE2 IN. MIN.SLOPE
1 IN. MIN.
8 IN. MIN.
6 IN.
15 IN. OR LESS 48 IN.
60 IN.18 IN. TO 30 IN.
72 IN.OVER 30 INCHES
MIN. MANHOLE
MINIMUM INSIDE DIAMETER OF
DIAMETER
MANHOLE SHALL BE AS FOLLOWS:
PIPE SIZE5 FT. MIN. DEPTHCONCRETE ADJUSTMENT SHIMS
GROUTED INSIDE
ASTM C-478 ECCENTRIC CONE
PRE-FORMED PLASTIC GASKET
ASTM C-478 MANHOLE SECTIONS
GROUT BASE TO BARREL
SECTION ON INSIDE
PRE-FORMED PLASTIC GASKET
CAST-IN-PLACE CONCRETE BASE
16 IN. MAX.
FINISHED GRADE
30 IN. MIN.48 IN. MAX.VARIABLE28 IN. MAX.
24 IN.
SEE TABLE
6 IN.
12 IN.
SLOPE
1 IN./FT.
18 IN.
MAX.
MANHOLE RUNGS
12 IN. O.C.
8 IN. MIN
STANDARD MANHOLE
WW-3
303 DROP MANHOLE DETAIL
PLAN VIEW
CROSS VIEW
45 ELBOW
SERVICE WYE
8 IN. PVC SEWER PIPE
COMPACTED GRANULAR MATERIAL
AIR-TIGHT PLUG WITH
4 IN. X 4 IN. MARKER
UNYIELDING PIPE BEDDING
OF COMPACTED ROCK OR
LEAN CONCRETE
PVC SEWER PIPE
NOTE: WYE CONNECTION NOT
ALLOWED ON VCP
LEAN CONCRETE
o
20 MIN.o
45 MAX.o
TRENCH
UNYIELDING PIPE BEDDING
OF COMPACTED ROCK OR
4 IN. X 4 IN.
MARKER
AIR-TIGHT PLUG
SERVICE WYE DETAIL
WW-9
FLOW DIRECTION
TRAFFIC RATED CLEANOUT
WW-15
0.015 STAINLESS STEEL STRAPS
(TO BE USED WITH REDWOOD SKIDS)
NOTE: CASING SPACERS MAY BE EITHER REDWOOD OR
STAINLESS STEEL WITH POLYMER RUNNERS.
TRANSMISSION LINE SUPPORTED
BY CASING SPACERS.
CASING SEAL CARRIER PIPE
STEEL CASING
1/4 IN. MIN.
CARRIER PIPE
CASING SPACERS
BELL OF PIPE
STEEL CASING
STEEL CASING DETAIL
WW-2
301 STEEL CASING DETAIL
REMOVABLE
EXPANSION PLUG
HAND-COMPACTED
GRANULAR BACKFILL
2 FT. MIN.
DROP MANHOLE
WW-4
305 TRAFFIC RATED CLEANOUT
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
C 803DRAINAGE DETAILS44
400 TYPICAL STORMWATER BEDDING
401 TYPICAL MANHOLE (STORM)
403 TYPICAL MANHOLE CHANNELING (STORM)
o
402 TYPICAL SHALLOW MANHOLE WITH
FLAT TOP
404 TYPICAL CURB, GUTTER, AND SIDEWALK
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
405 TYPICAL CULVERT, ATTACHED SIDEWALK
DETAIL "A"
PLAN VIEW
406 TYPICAL SIDEWALK CULVERT FOR DETACHED WALK - OUTFALL TO CURB
BACK OF CURB
EDGE OF STREET
5 8" GALV. STEEL PLATE
2
1
2
1
3"x2"x3 8" GALV. ANGLE
SEE DETAIL 1
#4@12"
O.C.
#4@12"
O.C.
#4@12"
O.C.
3"x2"x3 8"
GALV. ANGLE
5 8" GALV.
STEEL PLATE
#3 REBAR
ANCHOR
18 O.C.
3 8" BRASS SCREW
18 O.C. WITH
COUNTERSUNK HEAD
FLUSH WITH PLATE6"6"VARIES
2'
3'
SECTION B-B
DETAIL 1
SECTION A-A
PLAN
SECTION C-C
SLOPE
VARIES 0.5% SLOPE (MIN.)
VARIES VARIES
2' DEPRESSED GUTTER
VARIESEXPANSION
MATERIAL
5 8" GALV.
STEEL
PLATE
EDGE OF
STREET
12" R 12" R
2' OPENING 3'-3"3'-3"6" (TYP.)BACK
OF
CURB
3" (TYP.)
3' (TYP.)
SIDEWALK
(TYP.)
EXTEND WALK 6" ON
BOTH SIDES OF WALKVARIES
VARIESSLOPECC
BB
A
A
8'-6"
EXPANSION
MATERIAL
3 8" BRASS SCREW 18" O.C.
WITH COUNTERSINK
HEAD FLUSH WITH PLATE2'6"
500 TYPICAL SIDEWALK CULVERT FOR DETACHED WALK - INFALL TO SITE
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
C 804DRAINAGE DETAILS45
502 TYPICAL FLARED END SECTIONS
E
C B
E
E
C
D
PLAN
501 TYPICAL STREET CROSS PAN
GENERAL NOTES:
1. 6 IN. X 6 IN. X 10/10 WWF SHALL BE INSTALLED
IN RADIUS AND PAN.
2. MINIMUM 6 IN. WIDE PAN FOR RESIDENTIAL
STREET.
3. MINIMUM 10 FT. WIDE PAN FOR ARTERIAL AND
COLLECTOR STREETS.
EXPANSION
MATERIAL
5 8" GALV.
STEEL
PLATE
EDGE OF
STREET
12" R 12" R
2' OPENING 3'-3.0000"3'-3.0000"
6.0000" (TYP.)
BACK
OF
CURB
SLOPE PLATE TO
MATCH SIDEWALK
BACK OF CURB
EDGE OF STREET
5 8" GALV. STEEL PLATE
2
1
2
1
3"x2"x3 8" GALV. ANGLE
SEE DETAIL 1
#4@12"
O.C.
#4@12"
O.C.
#4@12"
O.C.
3"x2"x3 8"
GALV. ANGLE
5 8" GALV.
STEEL PLATE
#3 REBAR
ANCHOR
18 O.C.
3 8" BRASS SCREW
18 O.C. WITH
COUNTERSUNK HEAD
FLUSH WITH PLATE
6.0000"
VARIES
2'
3'
SECTION B-B
DETAIL 1
SECTION A-A
PLAN
SECTION C-C
SLOPE
VARIES
0.5% SLOPE (MIN.)
3.0000" (TYP.)
3' (TYP.)
SIDEWALK
(TYP.)
EXTEND WALK 6" ON
BOTH SIDES OF WALK
VARIES
VARIES
SLOPECC
BB
A
A
2' DEPRESSED GUTTER
VARIES
8'-6.0000"
EXPANSION
MATERIAL
3 8" BRASS SCREW 18" O.C.
WITH COUNTERSINK
HEAD FLUSH WITH PLATE 1'-11.9831"1.9658" MIN.
VARIES VARIES
2'
6.0000"
5.9991"
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
REV A7001-110-527DWG NO.1 OF 1SHEET1:30SCALEDWG SIZE A
DRAIN BASIN WITH 3 FT X 3 FT ROAD & HIGHWAY GRATE
QUICK SPEC INSTALLATION DETAIL
TITLE
PROJECT NO./NAME
MATERIAL
DATE
APPD BY
12-19-17DATE
NMHDRAWN BYTHIS PRINT DISCLOSES SUBJECT MATTER IN WHICH
NYLOPLAST HAS PROPRIETARY RIGHTS. THE RECEIPT
OR POSSESSION OF THIS PRINT DOES NOT CONFER,
TRANSFER, OR LICENSE THE USE OF THE DESIGN OR
TECHNICAL INFORMATION SHOWN HEREIN
REPRODUCTION OF THIS PRINT OR ANY INFORMATION
CONTAINED HEREIN, OR MANUFACTURE OF ANY
ARTICLE HEREFROM, FOR THE DISCLOSURE TO OTHERS
IS FORBIDDEN, EXCEPT BY SPECIFIC WRITTEN
PERMISSION FROM NYLOPLAST.
12-19-17
NMH
3130 VERONA AVE
BUFORD, GA 30518
PHN (770) 932-2443
FAX (770) 932-2490
www.nyloplast-us.com
®
©2007 NYLOPLAST
MINIMUM PIPE BURIAL
DEPTH PER PIPE
MANUFACTURER
RECOMMENDATION
(MIN. MANUFACTURING
REQ. SAME AS MIN. SUMP)
(2) VARIABLE INVERT HEIGHTS
AVAILABLE (ACCORDING TO
PLANS/TAKE OFF)
3 FT X 3 FT DUCTILE IRON FRAME &
GRATE TO MATCH BASIN O.D.
18" MIN WIDTH GUIDELINE
8" MIN THICKNESS GUIDELINE
TRAFFIC LOADS: CONCRETE SLAB DIMENSIONS ARE
FOR GUIDELINE PURPOSES ONLY. ACTUAL CONCRETE
SLAB MUST BE DESIGNED TAKING INTO CONSIDERATION
LOCAL SOIL CONDITIONS, TRAFFIC LOADING, & OTHER
APPLICABLE DESIGN FACTORS.
(4) ADAPTER
ANGLES
VARIABLE
0° - 360°
ACCORDING TO
PLANS
(2) VARIABLE SUMP DEPTH
ACCORDING TO PLANS
(6" MIN ON 24", 10" MIN ON 30" & 36"
BASED ON MANUFACTURING REQ.)
4" MIN ON 24" & 6" MIN ON 30" & 36"
24", 30" & 36"
(3) VARIOUS TYPES OF INLET & OUTLET ADAPTERS
AVAILABLE: 4" - 30" FOR CORRUGATED HDPE
(ADS N-12/HANCOR DUAL WALL, ADS/HANCOR
SINGLE WALL), N-12 HP, PVC SEWER (EX: SDR 35),
PVC DWV (EX: SCH 40), PVC C900/C905,
CORRUGATED & RIBBED PVC
WATERTIGHT JOINT
(CORRUGATED HDPE SHOWN)
NYLOPLAST 3 FT X 3FT ROAD & HIGHWAY STRUCTURE
1 - 24" - 30" FRAMES & 3 FT X 3 FT GRATES SHALL BE DUCTILE IRON PER ASTM A536
GRADE 70-50-05.
2 - DRAIN BASIN TO BE CUSTOM MANUFACTURED ACCORDING TO PLAN DETAILS.
3 - DRAINAGE CONNECTION STUB JOINT TIGHTNESS SHALL CONFORM TO
ASTM D3212 FOR CORRUGATED HDPE (ADS N-12/HANCOR DUAL WALL),
N-12 HP, & PVC SEWER.
4 - ADAPTERS CAN BE MOUNTED ON ANY ANGLE 0° TO 360°. TO
DETERMINE MINIMUM ANGLE BETWEEN ADAPTERS SEE DRAWING
NO. 7001-110-012.
5 - 3 FT X 3 FT ROAD & HIGHWAY GRATE SHALL MEET H-20 LOAD RATING.
503 NYLOPLAST 3 FT X 3 FT ROAD AND HIGHWAY GRATE
ROOF DRAIN CONNECTION505
REV C7001-110-042DWG NO.1 OF 1SHEET1:40SCALEDWG SIZE A
3130 VERONA AVE
BUFORD, GA 30518
PHN (770) 932-2443
FAX (770) 932-2490
www.nyloplast-us.com
8 IN - 30 IN TYPICAL INSTALLATION OPTIONS
TITLE
PROJECT NO./NAME
MATERIAL
DATE
APPD BY
8-10-00DATE
AWADRAWN BYTHIS PRINT DISCLOSES SUBJECT MATTER IN WHICH
NYLOPLAST HAS PROPRIETARY RIGHTS. THE RECEIPT
OR POSSESSION OF THIS PRINT DOES NOT CONFER,
TRANSFER, OR LICENSE THE USE OF THE DESIGN OR
TECHNICAL INFORMATION SHOWN HEREIN
REPRODUCTION OF THIS PRINT OR ANY INFORMATION
CONTAINED HEREIN, OR MANUFACTURE OF ANY
ARTICLE HEREFROM, FOR THE DISCLOSURE TO OTHERS
IS FORBIDDEN, EXCEPT BY SPECIFIC WRITTEN
PERMISSION FROM NYLOPLAST.
8-10-00
CJA DUCTILE IRONDO NOT POLLUTE DRAINS TO WATERWAYSNYLOPLASTTSALPOLYN
DU
CT I L E I R ONTSALPOLYNDUCTIL EIRONDUCTILE IRONDO NOT POLLUTE DRAINS TO WATERWAYSNYLOPLASTWHEN ARE DRAIN BASINS USED?
2808AG _ _ X
2810AG _ _ X
2812AG _ _ X
2815AG _ _ X
2818AG _ _ X
2824AG _ _ X
2830AG _ _ X
WHEN ARE INLINE DRAINS USED?
2708AG _ _ X
2710AG _ _ X
2712AG _ _ X
2715AG _ _ X
2718AG _ _ X
2724AG _ _ X
2730AG _ _ X
TYPICAL INSTALLATIONS
TYPICAL INSTALLATION OF NYLOPLAST
DRAIN BASIN AND INLINE DRAIN
1: TO ENTER AN EXISTING LINE
USING A TEE & RISER
2: AT THE BEGINNING OF A DRAIN LINE
USING AN ELBOW & RISER
TEE ELBOW
12" DRAIN BASIN
2 INLET & OUTLET
ADAPTERS CAN BE
PUT ON ANY ANGLE
1: TO CHANGE ELEVATION 2: TO CHANGE PIPE DIAMETER 3: TO CHANGE PIPE TYPE 4: FOR SHALLOW
APPLICATIONS 5: TO CHANGE DIRECTION
A°
RISER
DRAIN BASIN
INLINE DRAIN
10" INLINE DRAIN
10" INLINE DRAIN
3 VARIABLE ELEVATION
WATERTIGHT ADAPTERS AVAILABLE
FOR MOST COMMON PLASTIC PIPING SYSTEMS
8"6"
CORRUGATED
HDPE PIPE SMOOTH WALL
PVC
1 - STRUCTURES & ADAPTERS AVAILABLE IN SIZES 8" - 30"
2 - ADAPTERS CAN BE MOUNTED ON ANY ANGLE 0° TO 360°, TO DETERMINE
MINIMUM ANGLE BETWEEN ADAPTERS SEE DRAWING NO. 7001-110-012,
7001-110-013, & 7001-110-014
3 - DRAIN BASIN TO BE CUSTOM MANUFACTURED ACCORDING TO PLAN DETAILS
RISERS ARE NEEDED FOR BASINS OVER 84" DUE TO SHIPPING RESTRICTIONS
SEE DRAWING NO. 7001-110-065
504 TYPICAL BASIN INSTALLATION
C 805DRAINAGE DETAILS46
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
CAD FILE NAME:
DRAWN BY:T. COX
D46.dwg
8/15/05DATE DRAWN:
CC
A
A
B
B
3'-6"Ls1'
6"Ws6"6"VARIESVARIES6"Ws/2Ws/2SECTION C-C
SECTION A-A SECTION B-B
WELL SCREEN FLOW CONTROL PLATE
2'-6"6"WoWo
Wo
Wp
4"(TYP.)1'(MAX.)PLAN
6"3"CLR.D1
GENERAL NOTES
SECTION D-D
WQD
D
A A
OPP.
CLR.
ABBREVIATIONS
@
#
Wp
Wo
TYP.
DIA.
O.C.
MAX.
MIN.
LEGEND
WQINV.
ELEV.6"6"Ls
Ws
DETAIL
LAST DATE REVISED:4/7/11
POND 1 POND 2
ELEV A 5011.60 5015.40
ELEV B 5008.75 5012.95
ELEV C 5009.75 5013.925
D wq (FT)N/A 1.60
LS (FT)4.00 4.00
WS (FT)4.00 4.00
WO (FT)N/A 1.00
HOLE DIA (INCH)N/A 13/16
# ROWS N/A 5
# COLUMNS N/A 1
100-YEAR
ORIFICE DIA
(INCH)
4 9 3/4
602 OUTLET STRUCTURE
600 CURB INLET TYPE R (1 OF 2)601 CURB INLET TYPE R (2 OF 2)
603 QUINTUPLE COMBINATION CURB INLET
2-5 DETAIL
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
6"
5'-8" MAX
3'-0" MIN
5'-8" MAX
3'-0" MIN
6"
B
B
A A
14'-21
2"
2'-0"
SHIP-LAP JOINT
SEE GRATING DETAIL (RIGHT)
6"
6"
83
8"
18" RCP
3 - 19"X30"
ELLIPTICAL RCP
1'-23
8"
6"
6"
2'3'
14'-3 5
16"
6"6"
15'-3 5
16"
12"
FL-TBC
12" TAPERED CURB
12" TAPERED CURB
AA
4-TON P-52 SL
ANCHORS FOR SETTING
SUPPORT BEAM POCKET
(SEE BELOW)
SUPPORT BEAM POCKET
(SEE BELOW)
6" THICK
CONCRETE WALL
4-TON P-52 SL
ANCHORS FOR SETTING
M.A. STEPS @12" O.C.
(QUANTITY VARIES
WITH HEIGHT)
SEE GRATING
DETAIL (RIGHT)
800 TYPICAL CURB AND GUTTER
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
C 807SITE DETAILS476"2"R.2"6"6"12"1 1/2"R.
2'-6"
6"
4 1/2"
30"
9"
R 0.5"
4.5"
18"
3.63"
21.75"
R 0.13"
7"
2"
3.75"
12"
ROLL-OVER
VERTICAL
(LOVELAND)
Gutter edge may be
tapered or battered.
(Typical for all Curb &
& Gutter Types)7 3/8" (L)1 3/8"17"6"3 3/8"14"
FL
R 16"R 16"DRIVE-OVER CURB, GUTTER AND DETACHED SIDEWALK
31"
See Drawing 1601
10 3/4"(L)R 16"DRIVE-OVER CURB, GUTTER AND ATTACHED SIDEWALK
18"18"3 3/8"1 3/8"6"R 16"FL
14"6"17"
1 1/2"
5' (L)8 5/8" (F.C.)7 1/4" F.C.12" (F.C.)Slope to curb 1/4"/Ft.
1' min. (F.C.)
48:1 min.
4:1 max.
Excavation
Fill
1' min.
2' min.
1/4"/Ft.
CURB & GUTTER IN A CUT OR FILL
6"3'-9" (F.C.)
For Thickness
2' min. (L)
801 TYPICAL DRIVE-OVER CURB AND GUTTER AND SIDEWALK
802 TYPICAL MEDIAN ISLAND CURBS
6"1"1 1/2"R.
1'-6"
2" R.
4-1/2"12"6"OUT FALL CURB & GUTTER
8" BARRIER CURB
6"1'-0"a.) Bottom of curb shall be poured to a depth no less than on the compacted subgrade of the pavement.
6"6"6"1'-6"18"10"8"ROADWAY
PAVEMENT
FL LF
6" MOUNTABLE CURB
1 1/4"
BARRIER CURB (KEY WAY OR EPOXY)
1/8" TO 1/4"R.
1"± 1/4"
CONCRETE PAVEMENT
(SECTION B)
1 1/2"3"ASPHALT OR
6"
1 1/2"R.
1 1/2"
(SECTION M)
MOUNTABLE CURB (KEY WAY OR EPOXY)
3 1/2"3"
1"± 1/4"
1"R.
6"4"
1/8" TO 1/4"R.
6" w/concrete pavement
8" w/asphalt
*
*
6"
1-1/2"
b.) Raised center medians shall be 8" barrier curb or 8" epoxy curb only.
Notes:REVEAL(CDOT TYPE 2 SECTION B M-609-1 CURB W/8" REVEAL)6"(FORT COLLINS ONLY)
1-1/2" TO
Final asphalt lift,
overlay or grade
adjustment
Depress ring 1/4" to 5/8" below
adjacent finished street grade
Slope up to match
finished pavement
Straight cut
around ring
Concrete grade ring
to match slope or
finished grade
Grade ring
Existing base course
Manhole
Shim / Grout 16" max.NOTE:
1. Grout shall be a mixture of 100 lbs Grout mix, 26 lbs
water (3.12 Gal), and 100 lbs of sand conforming to ASTM C-35.
2. Manholes shall not be located in crosspans, gutters, or wheel path.
3. Shim and grout to make ring and cover flush with the finished
pavement surface.
Cover
Support with Steel Shims
and pack with High Strength
Grout
803 TYPICAL MANHOLE COVER
806 TYPICAL PAVEMENT MARKINGS
WITH TURN LANE
804 TYPICAL SIGN POST
805 TYPICAL PAVEMENT MARKINGS
Max. Sign Panel
1. Attach the sign panels tightly to the post and use oversized washers to keep the sign from breaking loose
from the post when hit by a vehicle.
2. Sign panels should be mounted a minimum of 7 feet above the pavement or ground.
Cross section of post
3" - 6" ABOVE GRADE
2 1/4" Anchor
3. Signs larger than 36 inches in length or width require wind bracing and special post design.
NOTES:
4. Anchor Stub and post are square steel tube (perforated).
Anchor/Stub Post Size
CRITERIA FOR SINGLE POST
36" x 36"2.25" x 2.25" x 3'-0"2" x 2" x 12'-0"
5. All "No Parking" signs shall be installed at 45° from Flow Line.
**
2" x 2" x 10' OR 12'
12 GAUGE TELESPAR POST
(22F12A31)7'-0" MIN. CLEARANCE2' - 3'
FROM F
Street Curb
See Figure 16-1
SW SAMPLEAVE
2400
R1-1 "STOP" SIGN 30" HIGH DENSITY/DIAMOND
GRADE. SIGN MOUNTED TO POST WITH 1 EACH
DRIVE RIVET WITH NYLON WASHER AGAINST SIGN
FACE (ON TOP OF THE SIGN). THE BOTTOM OF THE
SIGN SHALL BE MOUNTED WITH 1 EACH
5/16"x2-1/2" HEW BOLT WITH METAL AND FROM
NYLON WASHERS (NYLON WASHER AGAINST SIGN
FACE) AND SECURED WITH 1 EACH 5/16" HEX NUT
ON THE BACK SIDE OF POST.L
2-1/4" x 2-1/4" x 3'
ANCHOR/STUB
2 EACH 8" BLADES
MOUNTED TO POST
WITH 4 EACH DRIVE
RIVETS WITH
NYLON WASHERS
*12 Gauge 30"8"8"Double Lines
Normal Width Line
4" White
4" Yellow
4" Space
4" White
Preferential lane symbol
(6' X 4') for designated
bikeways. White pavement
marking placed 65' (min) from
the projected flowline and
Projected Flowline (FL)NO CROSSPAN
Continental bars (9' X 1.5'):NO CROSSPAN OR EXISTING CROSSPANWhite Stop Bar (1.5' X Length)
30' Gaps
3:1 Ratio
10' Segments
4" White
Broken Line STANDARDNO STOP BAR SPECIFIEDSTOP BAR SPECIFIED
STOP BAR SPECIFIED
EXISTING CROSSPAN
Crosspan exits (no stop bar) -- shall
No crosspan -- shall be positioned
along projected flowline.
match the edge of the pan.
Crosspan exits (stop bar specified) --
shall be positioned along projected
flowline overlapping 4' of crosspan.12
3
CROSSWALK MARKINGS
FL to stop bar
14.5' Projected
14.5' Stop
Bar to FL 13'9'1.5'
6' Crosspan
4'
4'
4'
NOTES:
Continental crosswalk bars shall be placed
centered on each lane line & in the center of
each lane. (Lanes 5' wide or less shall not
receive a bar centered in the lane.) Both outside
Continental bars shall be centered on the curb &
gutter when possible.
If 6' crosspan exists, bars to
match pan edge to 13' from
projected FL.
Exception: The downstream bike lane line shall
terminate at the curb return.
NOTE:
All longitudinal (lane) striping shall terminate at the
continental crosswalk bars when no stop bar exists.
If a stop bar is specified, the striping shall terminate
at the stop bar.
65' (min)
centered on bike lane.
PAVEMENT MARKINGS
Projected Flowline (FL)
Broken line 4" white
10' Segments
30' Gaps
(3:1 Ratio)
Wide Lane
1.5'x9'
8" White
Line 4" white
Double Line
4" Yellow
4" Space
CROSSWALK MARKINGS:
STRIPING:
PREFERENTIAL LANE SYMBOL:
STOP LINES:
MANDATORY MOVEMENT:
1.5'x9
100' Taper (min.).2L L = Turn Bay Storage Length.4L
10'
.4L
10'
4" Ywllow
4" White Extension Line
An Engineering study should be required before crosswalk markings are installed in locations away
from traffic signals or stop signs. Continental crosswalk bars (1.5' x 9' typ.) shall be placed adjacent
to the projected flowline or abutting to existing crosspan. A bar shall be placed centered on each
lane line and in the center of each lane. Lanes 5' wide or less shall not receive a bar centered in
the lane. It is important that the markings are in alignment with the access ramps / sidewalks.
On curves:
Dotted extension of lane edge with same
as solid downstream line, 2' segments, 4'
gaps.
Mandatory movement lanes shall
use a lane-use arrow marking, the
word marking "only", another
lane-use arrow marking
(accompanied by signs). Symbols
& words are 8' of more in height --
use CDOT specification sizes.
Place stop lines (1.5' x Variable typ.)
only when inportant to indicate the
point behind which vehicles are
required to stop (more often on main
arterials) -- placement should
ordinarily be 4' in advance of and
parallel to the nearest crosswalk line
in the absence of a marked
crosswalk, the stop line should be
placed at the desired stopping point
no more than 30' or less than 4' from
the nearest edge of the intersecting
roadway.PLS shall be used for designated
bikeways. Intersection placement
-- the symbol shall be placed
downstream to convey to turning
traffic that the bike lane exists. It
shall be placed 4" down from the
PCR & centered on the bike lane.
Frequency of placement between
blocks is a matter for Engineering
judgement.
All Longitudinal (lane) striping shall
terminate at the Continental crosswalk
bars -- except the downstream bike
lane which shall terminate at the curb
return. If a stop line is in place --
upstream stripping shall terminate at
the stop line.
Not Required with lane
lengths less than 100'.
Not Required with lane
lengths less than 100'.
8" White Line
8" White Extension Line8" White
Extension
4" White Line
65' (min)
4'
C 808SITE DETAILS48
900 TYPICAL BICYCLE LANE
PAVEMENT MARKINGS
904 TYPICAL ADA HANDICAP PARKING
REQUIREMENTS
901 TYPICAL STREET NAME SIGN
905 TYPICAL ACCESS RAMPS -
RESIDENTIAL LOCAL STREETS
906 TYPICAL TRUNCATED DOME PANEL
FOR ACCESS RAMPS
907 TYPICAL FIRE ACCESS ROAD SIGNS
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 48
20'
4" White Line
20'
4'
6'
Flow Line
Curb
2'VAN-ACCESSIBLEPARKINGMIN.MIN.ONE IN EVERYEIGHT ACCESSIBLESPACES, BUT NOTLESS THAN ONE,SHALL BE VANACCESSIBLE.ONE SIGNPER SPACEREQUIREDREQUIREDPER SPACEONE SIGNREQUIREDPER SPACEONE SIGNCAR ACCESSIBLEVAN ACCESSIBLE"UNIVERSAL DESIGN"CAR & VAN ACCESSIBLEORA "UNIVERSAL" PARKING SPACE DESIGN MAY BE USED.THIS DESIGN IS USED TO ACCOMMODATE CAR & VANACCESSIBLE PARKING SPACES, WHICH ELIMINATES THENEED FOR TWO SIGN TYPES.8'5'8'8'8'8'11'5'11'11'5'RESERVEDRESERVEDPARKINGRESERVEDPARKINGR7-8R7-8R7-8SW SAMPLEAVE
NOTES:
1. Street name must be 6" (min.) capital white letters, FHWA Series "B".
2. Prefix must be 2" letters, FHWA Series "B" and placed on the upper left.
3. Suffix must be 2" (min.) letters and block number must be 2" (min.) numbers, FHWA Series "B".
4. Overall sign length dimension varies according to length of street name.
5. All sign lettering and green background material must be at least Diamond Grade
sheeting per FHWA; No silk screened signs will be permitted.
6. Street numbers shall always point to higher block number.
7. Aluminum sign blank shall be 0.10 thickness with 3/4" radius corners.
8. Loveland only, signalized intersection signs shall be 18" (min.) in height.
9. All street name signs shall be retroreflective.
2400
Length Varies by Street Name
8"
1/2"
2-1/4"1/2"
2-3/4"
1/2"
2-1/2" Hwy B Series1" min.
2" max.
6" Hwy B Series
2-1/2" Hwy B Series,
Centered on Logo
3-3/4"
2-3/4"
1" min.
2" max.
1/2"
1/2"1/2"
FORT COLLINS ONLY
Notes: 1. Set ramp slopes using the center of theramp. 2. Truncated dome warning panel: Install panels along with the concrete pour for theramp. Specifications for the panel materialwill be provided upon request. 3. Each ramp shall align perpendicular to thestreet in which the ramp is provided to cross. 4. Refer to standard drawing 1606 in the Laimer County urban area street standardsfor other necessary criteria needed to construct these ramps that is not specifiedon this drawing. 5. Construct the ramps and walk so the cornerarea all drains to the street. 6. If curb and gutter are poured monolithic withramp, place dome edge at back of curb asshown. If not poured monolithic, place dome edge 6" from back of curb.PLAN VIEWNTSRamp
FlareGutterRampRampFlareCurbCurbConc. FlarePanelsPanelsTruncated domepanels:1-2'x2.5'1-2'x2'Truncated Dome WarningDetection Plan LocationsLEGEND:BOC- Back of curb⅊ Property LinePT - Point of TangencyFlow line Section A-A NTS4'-6"2'-0"2'-6"2'-0"t
Varies
Varies 4.5'6.0'.5'1.5'4.5'1.5 '12.0'12.0'4.5'.5'6.0'4.5'L
a
n
d
s
c
a
p
e
d
A
r
e
a
PT CurbAA6" Curb(TYP)0" CurbFull heightcurbTruncated domewarning detection⅊PT of walkR15.0'⅊⅊ & BOW5'-6" BOC to walk w/ vertical curb5'-7" BOC to walk w/ drive over curbConc. SidewalkArea to be landscapedConc. walkGutterorApronTruncate DomeWarning Panel1:12 Max slope1:20SlopePT of curbreturn6"Conc. Flare6" Curb(TYP)See note 6
CurbFlareVaries
CurbFlareRampCurbCurb
FlareRampVaries PanelsPanels6"RampWidth:4.5'5.0'6.0'7.0'8.0'Note:Truncated dome panels areavailable in 2'x2' squaresand 2'x2.5' rectangles.Combine the widths to fitthe ramp. Panels may becut to no less than a 2'x1.5'size.Panel WidthCombinations:2'+2.5'2.5'+2.5'2'+2'+2'2.5'+2'+2.5'2'+2'+2'+2'Notes: 1. Truncated dome warning panel: Install panels along with the concrete pour for the ramp. Specifications for the panel and installation instructions will be provided upon request. 2. This drawing shows vertical curb.For Drive Over Curb the warning detection location shall be placed inthe same position 6" back from theback of curb. 3. If curb and gutter are poured monolithic with ramp, place domeedge at back of curb as shown. Ifnot poured monolithic, place domeedge 6" from back of curb.Case 1-Directional RampsCase 2-Non-Directional RampsVaries
PanelsRampPanelsFlareCurbCase 3-Mid-Block Ramps6"PanelsPanelsFlare6"FlareVaries
FORT COLLINS ONLY
Aligned with
Pedestrian flow
GutterorApron℄Center line of rampBOC-Back of CurbFOC -Face of Curb-Flow lineVaries
2'-0"
2'-0"AAFOC or ℄
2'-0"BOCBOC1:12 max slope1:20slopePanels embedded in theconcrete ramps Section A-A (Center line of ramp)NTSFlow line Curb
and Gutter
BOC
See Note 3
NOTES:
1. THE SIGN PLATE SHALL BE A MINIMUM OF 12"X18" WITH A THICKNESS OF .080
ALUMINUM CONSTRUCTION.
2. THE SIGN FACE SHALL HAVE A WHITE REFLECTIVE BACKGROUND WITH A RED
LEGEND. USE THE STANDARD 3M SCOTCHLITE SIGN FACE NUMBER R7-32 OR
EQUIVALENT, WITH RED LETTERING AS SHOWN ABOVE.
3. ARROWS MAY BE NEEDED (LEFT, RIGHT OR DOUBLE), TO DESIGNATE BEGIN AND END OF
NO PARKING AREA.
FIRE
LANE
NO
PARKING
BY ORDER OF THE
FIRE MARSHAL
STANDARD
FIRE LANE SIGN DETAIL
UNIVERSAL
FIRE LANE SIGN DETAIL
18"
2"
1 1/2"
3/4"
12"12"
FIRE LANE
COLOR SCHEDULE
BACKGROUND
"P"
RED
WHITE
BLACK
LEGEND, CIRCLE DIAGONAL, BORDER,
"ARROW", "FIRE LANE"
(FORT COLLINS ONLY)
903 12' CONCRETE TRAIL/
ACCESS ROAD SECTION
PAVEMENT CROSS-SECTIONS
902
LOCATION COMPOSITE ASHPALT SECTION
(INCHES ASPHALT / INCHES ABC)
FULL DEPTH ASPHALT
SECTION
(INCHES ASPHALT)
RIGID PAVEMENT
(INCHES PCCP/INCHES ABC or SCS)
PARKING AREAS 4.0 / 7 6.0 -
DRIVE AISLES 4.5 / 9 7.0 5 / 5 (ABC)
HEAVY DUTY 6 / 6 (ABC)
ABC = AGGERGATE BASE COURSE, PCCP = PORTLAND CEMENT CONCRETE PAVEMENT
SCS = SCARIFIED/COMPACTED SUBGRADE
--
412 PAVER EDGE RESTRAINT