HomeMy WebLinkAboutTHE QUARRY BY WATERMARK - FDP210016 - DOCUMENT MARKUPS - ROUND 2 - UTILITY PLANS (3)PROSPECT ROADSHIELDS STREETLAKE STREET
PITKIN STREET
STUART STREET
HOBBIT ST.SHEELY DR
.
HILL POND R
D
.
CONNECTOR LOCAL STREET SECTION
MODIFIED - (HOBBIT STREET)EX. 8' PARKING LANE10' TRAVEL LANEEX. 10' TRAVEL LANEEXISTING DRIVE-OVER
CURB & GUTTER
VERTICAL
CURB & GUTTER
57' ROW
EX . 9'
UTIL.
ESMT.
9' UTIL.
ESMT.
4.5'
WALK
EX. 6'
PKWY.
36' -
6'
PKWY.
EX. 4.5'
WALK
8' PARKING LANECALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what's below.
before you dig.Call
R
JULY 2021
UTILITY PLANS FOR
CONTACT INFORMATION
PROJECT TEAM:
Ripley Design, Inc.
419 Canyon Avenue, Suite 200
Fort Collins, CO. 80521
(970) 224-5828
Watermark Residential
111 Monument Circle, Suite 1500
Indianapolis, IN. 46204
(317) 853-5459
UTILITY CONTACT LIST: *
UTILITY COMPANY
* This list is provided as a courtesy reference only. Northern Engineering Services assumes no responsibility for
the accuracy or completeness of this list. In no way shall this list relinquish the Contractor's responsibility for
locating all utilities prior to commencing any construction activity. Please contact the Utility Notification Center of
Colorado (UNCC) at 811 for additional information.
PHONE NUMBER
Northern Engineering Services, Inc.
Danny Weber, PE
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
(970) 221-4158
Northern Engineering Services, Inc.
Bob Tessely, PLS
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
(970) 221-4158
E N G I N E E R N GI
EHTRON R N
E N G I N E E R N GI
EHTRON R N
PLANNER/
LANDSCAPE ARCHITECT
I hereby affirm that these final
construction plans were prepared
under my direct supervision, in
accordance with all applicable City
of Fort Collins and State of
Colorado standards and statutes,
respectively; and that I am fully
responsible for the accuracy of all
design. revisions, and record
conditions that I have noted on
these plans.
These plans have been reviewed by the City of Fort Collins for concept only. The review does not imply responsibility
by the reviewing department, the City of Fort Collins Engineer, or the City of Fort Collins for accuracy and correctness
of the calculations. Furthermore, the review does not imply that quantities of items on the plans are the final quantities
required. The review shall not be construed for any reason as acceptance of financial responsibility by the City of Fort
Collins for additional quantities of items shown that may be required during the construction phase.
DISCLAIMER STATEMENT:
CERTIFICATION STATEMENT:
PROJECT
LOCATION
VICINITY MAP
NORTH
DEVELOPER/APPLICANT
SITE ENGINEER
SURVEYOR
ORIGINAL FIELD SURVEY BY:
SUBSURFACE EXPLORATION BY:
PROJECT BENCHMARKS:
SHEET INDEX
THE QUARRY BY WATERMARK
GAS-----------------------Xcel Energy-----------------------------Al Ermer (970) 225-7869
ELECTRIC--------------City of Fort Collins Light & Power--Luke Unruh (970) 416-2724
CABLE-------------------Comcast----------------------------------Don Kapperman (970) 567-0245
TELECOM.-------------Qwest Local Network------------------Bill Johnson (970) 377-6401
WATER------------------City of Fort Collins Utilities-----------Matt Simpson (970) 416-2754
WASTEWATER-------City of Fort Collins Utilities-----------Matt Simpson (970) 416-2754
STORMWATER-------City of Fort Collins Utilities-----------Matt Simpson (970) 416-2754
W/WW INSPECTOR--City of Fort Collins Utilities-----------Jim McChesney (970) 556-8179
Earth Engineering Consultants, LLC.
"GEOTECHNICAL EXPLORATION REPORT SHIELDS MIXED USE DEVELOPMENT SOUTH OF HOBBIT STREET,
EAST OF SOUTH SHIELDS STREET"
Soilogic Project No. 1152075
Date: August 21, 2015
PROJECT DATUM: NAVD88
BENCHMARK 29-92 APPROXIMATE 300 FEET SOUTH OF WEST PROSPECT ROAD AND
SHIELDS STREET, ON THE NORTH END OF THE WEST BRIDGE PARAPET WALL.
ELEVATION: 5025.67
BENCHMARK 28-92 SOUTHWEST CORNER OF WEST PROSPECT ROAD AND CENTER
AVENUE, ON A WATER VALVE PIT.
ELEVATION: 5010.65
PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM.
SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED DATUM (PRIOR
CITY OF FORT COLLINS DATUM) FOR THEIR VERTICAL DATUMS.
IF NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) IS REQUIRED
FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29
UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) = NAVD88 - 3.17'.
BASIS OF BEARINGS
WEST LINE OF THE NORTHWEST QUARTER OF SECTION 23 AS BEARING NORTH 00°
01' 50" EAST (ASSUMED BEARING), AND MONUMENTED AS SHOWN ON DRAWING.
1 C 001 COVER SHEET
2 C 100 GENERAL & CONSTRUCTION NOTES
3 C 200 EXISTING CONDITIONS & DEMOLITION PLAN
4 C 300 EROSION CONTROL PLAN
5 C 301 EROSION CONTROL DETAILS
6 - 9 C 400 - C 403 PAVING PLAN
10 C 410 INTERSECTION STRIPING PLAN
11 C 500 OVERALL GRADING PLAN
12 - 17 C 501 - C 506 GRADING PLAN
18 C 510 SUBGRADE PLAN
19 C 600 OVERALL UTILITY PLAN
20 - 23 C 601 - C 604 UTILITY PLAN
24 C 610 SANITARY SEWER LINES A & A3 PLAN & PROFILE
25 C 611 SANITARY SEWER LINES B & B3 PLAN & PROFILE
26 C 612 SANITARY SEWER LINES C & D PLAN & PROFILE
27 C 620 STORM DRAIN 1 PLAN & PROFILE
28 C 621 STORM DRAINS 1-5 & 1-6 PLAN & PROFILE
29 C 622 STORM DRAINS 1-8 & 1-9 PLAN & PROFILE
30 C 623 STORM DRAINS 2, 2A & 3 PLAN & PROFILE
31 C 624 STORM DRAINS 4, 4-4A, & 4-4 PLAN & PROFILE
32 C 625 STORM DRAINS 5 & 5-2 PLAN & PROFILE
33 C 626 STORM DRAIN 6 & UNDERDRAIN PLAN & PROFILE
34 C 700 HISTORIC DRAINAGE EXHIBIT
35 C 701 DRAINAGE EXHIBIT
36 - 37 C 800 - C 801 WATER DETAILS
38 C 802 SANITARY SEWER DETAILS
39 - 41 C 803 - C 805 DRAINAGE DETAILS
42 - 43 C 806 - C 807 SITE DETAILS
C 001COVER SHEET1
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 43
TYPICAL SECTIONS
BEING A REPLAT OF LOTS 1-5, TRACT "A", TRACT "B", ALABASTER COURT, COROMANDEL CIRCLE AND STUART STREET, PULSE P.U.D. FILING ONE, LOCATED IN THE NORTHWEST
QUARTER OF SECTION 23, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH PRINCIPAL MERIDIAN, CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO
Intermill Land Surveying, Inc.Northern Engineering Services, Inc.
Company Project No. P-11-6963 Company Project No. 838-016
Date: April 2011 Date: July 2015
King Surveyors
Company Project No. 20190806
Date: January 2020
City of Fort Collins, CO
UTILITY PLAN APPROVAL
APPROVED:
CITY ENGINEER,APPROVED SHEETS DATE
APPROVED:
WATER & WASTEWATER UTILITY,APPROVED SHEETS DATE
APPROVED:
STORMWATER UTILITY,APPROVED SHEETS DATE
APPROVED:
PARK PLANNING & DEVELOPMENT,APPROVED SHEETS DATE
APPROVED:
TRAFFIC OPERATIONS,APPROVED SHEETS DATE
APPROVED:
ENVIRONMENTAL PLANNER,APPROVED SHEETS DATE
■ land planning ■ landscape architecture ■
■ urban design ■ entitlement ■
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what's below.
before you dig.Call
R
A. GENERAL NOTES
1.All materials, workmanship, and construction of public improvements shall meet or exceed the standards and specifications set forth in the Larimer
County Urban Area Street Standards and applicable state and federal regulations. Where there is conflict between these plans and the specifications, or
any applicable standards, the most restrictive standard shall apply. All work shall be inspected and approved by the City of Fort Collins.
2.All references to any published standards shall refer to the latest revision of said standard, unless specifically stated otherwise.
3.These public improvement construction plans shall be valid for a period of three years from the date of approval by the City of Fort Collins Engineer. Use
of these plans after the expiration date will require a new review and approval process by the City of Fort Collins prior to commencement of any work
shown in these plans.
4.The engineer who has prepared these plans, by execution and/or seal hereof, does hereby affirm responsibility to the City of Fort Collins, as beneficiary
of said engineer's work, for any errors and omissions contained in these plans, and approval of these plans by the City of Fort Collins Engineer shall not
relieve the engineer who has prepared these plans of all such responsibility. Further, to the extent permitted by law, the engineer hereby agrees to hold
harmless and indemnify the City of Fort Collins, and its officers and employees, from and against all liabilities, claims, and demands which may arise
from any errors and omissions contained in these plans.
5.All sanitary sewer, storm sewer and water line construction, as well as power and other "dry" utility installations, shall conform to the City of Fort Collins
standards and specifications current at the date of approval of the plans by the City of Fort Collins Engineer.
6.The type, size, location and number of all known underground utilities are approximate when shown on the drawings. It shall be the responsibility of the
Developer to verify the existence and location of all underground utilities along the route of the work before commencing new construction. The
Developer shall be responsible for unknown underground utilities.
7.The Developer shall contact the Utility Notification Center of Colorado (UNCC) at 1-800-922-1987, at least 2 working days prior to beginning excavation
or grading, to have all registered utility locations marked. Other unregistered utility entities (i.e. ditch / irrigation company) are to be located by contacting
the respective representative. Utility service laterals are also to be located prior to beginning excavation or grading. It shall be the responsibility of the
Developer to relocate all existing utilities that conflict with the proposed improvements shown on these plans.
8.The Developer shall be responsible for protecting all utilities during construction and for coordinating with the appropriate utility company for any utility
crossings required.
9.If a conflict exists between existing and proposed utilities and/or a design modification is required, the Developer shall coordinate with the engineer to
modify the design. Design modification(s) must be approved by the City of Fort Collins prior to beginning construction.
10.The Developer shall coordinate and cooperate with the City of Fort Collins, and all utility companies involved, to assure that the work is accomplished in a
timely fashion and with a minimum disruption of service. The Developer shall be responsible for contacting, in advance, all parties affected by any
disruption of any utility service as well as the utility companies.
11.No work may commence within any public storm water, sanitary sewer or potable water system until the Developer notifies the utility provider. Notification
shall be a minimum of 2 working days prior to commencement of any work. At the discretion of the water utility provider, a pre-construction meeting may
be required prior to commencement of any work.
12.The Developer shall sequence installation of utilities in such a manner as to minimize potential utility conflicts. In general, storm sewer and sanitary
sewer should be constructed prior to installation of the water lines and dry utilities.
13.The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the Water Utility.
14.A State Construction Dewatering Wastewater Discharge Permit is required if dewatering is required in order to install utilities or if water is discharged into
a storm sewer, channel, irrigation ditch or any waters of the United States.
15.The Developer shall comply with all terms and conditions of the Colorado Permit for Storm Water Discharge (Contact Colorado Department of Health,
Water Quality Control Division, (303) 692-3590), the Storm Water Management Plan, and the Erosion Control Plan.
16.The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite
drainage facilities shall be the responsibility of the property owner(s).
17.Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must be submitted to
and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the
release of a certificate of occupancy for single family units. For commercial properties, certification shall be submitted to the Stormwater Utility
Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development
Agreement.
18.The City of Fort Collins shall not be responsible for any damages or injuries sustained in this Development as a result of groundwater seepage, whether
resulting from groundwater flooding, structural damage or other damage unless such damage or injuries are sustained as a result of the City of Fort
Collins failure to properly maintain its water, wastewater, and/or storm drainage facilities in the development.
19.All recommendations of the Final Drainage and Erosion Control Report for The Quarry by Watermark, dated July 14, 2021 by Northern Engineering
Services, Inc. shall be followed and implemented.
20.Temporary erosion control during construction shall be provided as shown on the Erosion Control Plan. All erosion control measures shall be maintained
in good repair by the Developer, until such time as the entire disturbed areas is stabilized with hard surface or landscaping.
21.The Developer shall be responsible for insuring that no mud or debris shall be tracked onto the existing public street system. Mud and debris must be
removed within 24 hours by an appropriate mechanical method (i.e. machine broom sweep, light duty front-end loader, etc.) or as approved by the the
City of Fort Collins street inspector.
22.No work may commence within any improved or unimproved public Right-of-Way until a Right-of-Way Permit or Development Construction Permit is
obtained, if applicable.
23.The Developer shall be responsible for obtaining all necessary permits for all applicable agencies prior to commencement of construction. The Developer
shall notify the the City of Fort Collins Inspector (Fort Collins - 221-6605) and the City of Fort Collins Erosion Control Inspector (Fort Collins - 221-6700)
at least 2 working days prior to the start of any earth disturbing activity, or construction on any and all public improvements. If the City of Fort Collins
Engineer is not available after proper notice of construction activity has been provided, the Developer may commence work in the Engineer absence.
However, the City of Fort Collins reserves the right not to accept the improvement if subsequent testing reveals an improper installation.
24.The Developer shall be responsible for obtaining soils tests within the Public Right-of-Way after right of way grading and all utility trench work is complete
and prior to the placement of curb, gutter, sidewalk and pavement. If the final soils/pavement design report does not correspond with the results of the
original geotechnical report, the Developer shall be responsible for a re-design of the subject pavement section or, the Developer may use the City of
Fort Collins' default pavement thickness section(s). Regardless of the option used, all final soils/pavement design reports shall be prepared by a licensed
Professional Engineer. The final report shall be submitted to the Inspector a minimum of 10 working days prior to placement of base and asphalt.
Placement of curb, gutter, sidewalk, base and asphalt shall not occur until the City of Fort Collins Engineer approves the final report.
25.The contractor shall hire a licensed engineer or land surveyor to survey the constructed elevations of the street subgrade and the gutter flowline at all
intersections, inlets, and other locations requested by the the City of Fort Collins inspector. The engineer or surveyor must certify in a letter to the City of
Fort Collins that these elevations conform to the approved plans and specifications. Any deviations shall be noted in the letter and then resolved with the
City of Fort Collins before installation of base course or asphalt will be allowed on the streets.
26.All utility installations within or across the roadbed of new residential roads must be completed prior to the final stages of road construction. For the
purposes of these standards, any work except c/g above the subgrade is considered final stage work. All service lines must be stubbed to the property
lines and marked so as to reduce the excavation necessary for building connections.
27.Portions of Larimer County are within overlay districts. The Larimer County Flood Plain Resolution should be referred to for additional criteria for roads
within these districts.
28.All road construction in areas designated as Wild Fire Hazard Areas shall be done in accordance with the construction criteria as established in the Wild
Fire Hazard Area Mitigation Regulations in force at the time of final plat approval.
29.Prior to the commencement of any construction, the contractor shall contact the Local Entity Forester to schedule a site inspection for any tree removal
requiring a permit.
30.The Developer shall be responsible for all aspects of safety including, but not limited to, excavation, trenching, shoring, traffic control, and security. Refer
to OSHA Publication 2226, Excavating and Trenching.
31.The Developer shall submit a Construction Traffic Control Plan, in accordance with MUTCD, to the appropriate Right-of-Way authority. (The the City of
Fort Collins, Larimer County, Colorado), for approval, prior to any construction activities within, or affecting, the Right-of-Way. The Developer shall be
responsible for providing any and all traffic control devices as may be required by the construction activities.
32.Prior to the commencement of any construction that will affect traffic signs of any type, the contractor shall contact the City of Fort Collins Traffic
Operations Department, who will temporarily remove or relocate the sign at no cost to the contractor, however, if the contractor moves the traffic sign
then the contractor will be charged for the labor, materials and equipment to reinstall the sign as needed.
33.The Developer is responsible for all costs for the initial installation of traffic signing and striping for the Development related to the Development's local
street operations. In addition, the Developer is responsible for all costs for traffic signing and striping related to directing traffic access to and from the
Development.
34.There shall be no site construction activities on Saturdays, unless specifically approved by the City of Fort Collins Engineer, and no site construction
activities on Sundays or holidays, unless there is prior written approval by the City of Fort collins.
35.The Developer is responsible for providing all labor and materials necessary for the completion of the intended improvements, shown on these drawings,
or designated to be provided, installed, or constructed, unless specifically noted otherwise.
36.Dimensions for layout and construction are not to be scaled from any drawing. If pertinent dimensions are not shown, contact the Designer for
clarification, and annotate the dimension on the as-built record drawings.
37.The Developer shall have, onsite at all times, one (1) signed copy of the approved plans, one (1) copy of the appropriate standards and specifications,
and a copy of any permits and extension agreements needed for the job.
38.If, during the construction process, conditions are encountered which could indicate a situation that is not identified in the plans or specifications, the
Developer shall contact the Designer and the City of Fort Collins Engineer immediately.
39.The Developer shall be responsible for recording as-built information on a set of record drawings kept on the construction site, and available to the
Larimer County's Inspector at all times. Upon completion of the work, the contractor(s) shall submit record drawings to the City of Fort Collins Engineer.
40.The Designer shall provide, in this location on the plan, the location and description of the nearest survey benchmarks (2) for the project as well as the
basis of bearings. The information shall be as follows:
PROJECT DATUM: NAVD88
BENCHMARK 29-92 APPROXIMATE 300 FEET SOUTH OF WEST PROSPECT ROAD AND SHIELDS STREET, ON THE NORTH END OF THE
WEST BRIDGE PARAPET WALL.
ELEVATION: 5025.67
BENCHMARK 28-92 SOUTHWEST CORNER OF WEST PROSPECT ROAD AND CENTER AVENUE, ON A WATER VALVE PIT.
ELEVATION: 5010.65
PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29
UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) FOR THEIR VERTICAL DATUMS.
IF NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION
SHOULD BE USED: NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) = NAVD88 - 3.17'.
BASIS OF BEARINGS
WEST LINE OF THE NORTHWEST QUARTER OF SECTION 23 AS BEARING NORTH 00° 01' 50" EAST (ASSUMED BEARING), AND
MONUMENTED AS SHOWN ON DRAWING.
41.All stationing is based on centerline of roadways unless otherwise noted.
42.Damaged curb, gutter and sidewalk existing prior to construction, as well as existing fences, trees, streets, sidewalks, curbs and gutters, landscaping,
structures, and improvements destroyed, damaged or removed due to construction of this project, shall be replaced or restored in like kind at the
Developer's expense, unless otherwise indicated on these plans, prior to the acceptance of completed improvements and/or prior to the issuance of the
first Certificate of Occupancy.
43.When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street
condition shall be documented by the City of Fort Collins Construction Inspector before any cuts are made. Patching shall be done in accordance with
the City of Fort Collins Street Repair Standards. The finished patch shall blend in smoothly into the existing surface. All large patches shall be paved with
an asphalt lay-down machine. In streets where more than one cut is made, an overlay of the entire street width, including the patched area, may be
required. The determination of need for a complete overlay shall be made by the Larimer County Engineer and/or the City of Fort Collins Inspector at the
time the cuts are made.
44.Upon completion of construction, the site shall be cleaned and restored to a condition equal to, or better than, that which existed before construction, or
to the grades and condition as required by these plans.
45.Standard Handicap ramps are to be constructed at all curb returns and at all "T" intersections.
46.After acceptance by the City of Fort Collins, public improvements depicted in these plans shall be guaranteed to be free from material and workmanship
defects for a minimum period of two years from the date of acceptance.
47.The City of Fort Collins shall not be responsible for the maintenance of roadway and appurtenant improvements, including storm drainage structures and
pipes, for the following private streets: N.A.
48.Portions of the property are within FEMA Floodplain Zone AE, Fort Collins designated Floodplain and Fort Collins designated floodway. A Floodplain
Use Permit is required for any development within the floodplain. See Grading Plan for detailed notes concerning construction within the floodplain and
floodway.
49.Approved Variances are listed as follows:
CONSTRUCTION NOTES
A. Grading and Erosion Control Notes
1.The erosion control inspector must be notified at least twenty-four (24) hours prior to any construction on this site.
2.There shall be no earth-disturbing activity outside the limits designated on the accepted plans.
3.All required perimeter silt and construction fencing shall be installed prior to any land disturbing activity (stockpiling, stripping, grading, etc). All other
required erosion control measures shall be installed at the appropriate time in the construction sequence as indicated in the approved project schedule,
construction plans, and erosion control report.
4.At all times during construction, the Developer shall be responsible for preventing and controlling on-site erosion including keeping the property
sufficiently watered so as to minimize wind blown sediment. The Developer shall also be responsible for installing and maintaining all erosion control
facilities shown herein.
5.Pre-disturbance vegetation shall be protected and retained wherever possible. Removal or disturbance of existing vegetation shall be limited to the
area(s) required for immediate construction operations, and for the shortest practical period of time.
6.All soils exposed during land disturbing activity (stripping, grading, utility installations, stockpiling, filling, etc.) shall be kept in a roughened condition by
ripping or disking along land contours until mulch, vegetation, or other permanent erosion control BMPs are installed. No soils in areas outside project
street rights-of-way shall remain exposed by land disturbing activity for more than thirty (30) days before required temporary or permanent erosion control
(e.g. seed/mulch, landscaping, etc.) is installed, unless otherwise approved by the City/County.
7.In order to minimize erosion potential, all temporary (structural) erosion control measures shall:
a.Be inspected at a minimum of once every two (2) weeks and after each significant storm event and repaired or reconstructed as necessary in order
to ensure the continued performance of their intended function.
b.Remain in place until such time as all the surrounding disturbed areas are sufficiently stabilized as determined by the erosion control inspector.
c.Be removed after the site has been sufficiently stabilized as determined by the erosion control inspector.
8.When temporary erosion control measures are removed, the Developer shall be responsible for the clean up and removal of all sediment and debris from
all drainage infrastructure and other public facilities.
9.The contractor shall immediately clean up any construction materials inadvertently deposited on existing streets, sidewalks, or other public rights of way,
and make sure streets and walkways are cleaned at the end of each working day.
10.All retained sediments, particularly those on paved roadway surfaces, shall be removed and disposed of in a manner and location so as not to cause
their release into any waters of the United States.
11.No soil stockpile shall exceed ten (10) feet in height. All soil stockpiles shall be protected from sediment transport by surface roughening, watering, and
perimeter silt fencing. Any soil stockpile remaining after thirty (30) days shall be seeded and mulched.
12.The stormwater volume capacity of detention ponds will be restored and storm sewer lines will be cleaned upon completion of the project and before
turning the maintenance over to the City/County or Homeowners Association (HOA).
13.City Ordinance and Colorado Discharge Permit System (CDPS) requirements make it unlawful to discharge or allow the discharge of any pollutant or
contaminated water from construction sites. Pollutants include, but are not limited to discarded building materials, concrete truck washout, chemicals, oil
and gas products, litter, and sanitary waste. The developer shall at all times take whatever measures are necessary to assure the proper containment
and disposal of pollutants on the site in accordance with any and all applicable local, state, and federal regulations.
14.A designated area shall be provided on site for concrete truck chute washout. The area shall be constructed so as to contain washout material and
located at least fifty (50) feet away from any waterway during construction. Upon completion of construction activities the concrete washout material will
be removed and properly disposed of prior to the area being restored.
15.Conditions in the field may warrant erosion control measures in addition to what is shown on these plans. The Developer shall implement whatever
measures are determined necessary, as directed by the City.
B. Street Improvement Notes
1.All street construction is subject to the General Notes on the cover sheet of these plans as well as the Street Improvements Notes listed here.
2.A paving section design, signed and stamped by a Colorado licensed Engineer, must be submitted to the City of Fort Collins Engineer for approval, prior
to any street construction activity, (full depth asphalt sections are not permitted at a depth greater than 8 inches of asphalt). The job mix shall be
submitted for approval prior to placement of any asphalt.
3.Where proposed paving adjoins existing asphalt, the existing asphalt shall be saw cut, a minimum distance of 12 inches from the existing edge, to create
a clean construction joint. The Developer shall be required to remove existing pavement to a distance where a clean construction joint can be made.
Wheel cuts shall not be allowed unless approved by the City of Fort Collins Engineer in Fort Collins.
4.Street subgrades shall be scarified the top 12 inches and re-compacted prior to subbase installation. No base material shall be laid until the subgrade has
been inspected and approved by the City of Fort Collins Engineer.
5.Ft. Collins only. Valve boxes and manholes are to be brought up to grade at the time of pavement placement or overlay. Valve box adjusting rings are not
allowed.
6.When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street
condition shall be documented by the Inspector before any cuts are made. Cutting and patching shall be done in conformance with Chapter 25,
Reconstruction and Repair. The finished patch shall blend smoothly into the existing surface. The determination of need for a complete overlay shall be
made by the City of Fort Collins Engineer. All overlay work shall be coordinated with adjacent landowners such that future projects do not cut the new
asphalt overlay work.
7.All traffic control devices shall be in conformance with these plans or as otherwise specified in M.U.T.C.D. (including Colorado supplement) and as per
the Right-of-Way Work Permit traffic control plan.
8.The Developer is required to perform a gutter water flow test in the presence of the City of Fort Collins Inspector and prior to installation of asphalt.
Gutters that hold more than 1/4 inch deep or 5 feet longitudinally, of water, shall be completely removed and reconstructed to drain properly.
9.Prior to placement of H.B.P. or concrete within the street and after moisture/density tests have been taken on the subgrade material (when a full depth
section is proposed) or on the subgrade and base material (when a composite section is proposed), a mechanical "proof roll" will be required. The entire
subgrade and/or base material shall be rolled with a heavily loaded vehicle having a total GVW of not less than 50,000 lbs. and a single axle weight of at
least 18,000 lbs. with pneumatic tires inflated to not less that 90 p.s.i.g. "Proof roll" vehicles shall not travel at speeds greater than 3 m.p.h. Any portion of
the subgrade or base material which exhibits excessive pumping or deformation, as determined by the City of Fort Collins Engineer, shall be reworked,
replaced or otherwise modified to form a smooth, non-yielding surface. The City of Fort Collins Engineer shall be notified at least 24 hours prior to the
"proof roll." All "proof rolls" shall be preformed in the presence of an Inspector.
C. Traffic Signing and Pavement Marking Construction Notes
1.All signage and marking is subject to the General Notes on the cover sheet of these plans, as well as the Traffic Signing and Marking Construction Notes
listed here.
2.All symbols, including arrows, ONLYS, crosswalks, stop bars, etc. shall be pre-formed thermo-plastic.
3.All signage shall be per the City of Fort Collins Standards and these plans or as otherwise specified in MUTCD.
4.All lane lines for asphalt pavement shall receive two coats of latex paint with glass beads.
5.All lane lines for concrete pavement should be epoxy paint.
6.Prior to permanent installation of traffic striping and symbols, the Developer shall place temporary tabs or tape depicting alignment and placement of the
same. Their placement shall be approved by the City of Fort Collins Traffic Engineer prior to permanent installation of striping and symbols.
7.Pre-formed thermo-plastic applications shall be as specified in these Plans and/or these Standards.
8.Epoxy applications shall be applied as specified in CDOT Standard Specifications for Road and Bridge Construction.
9.All surfaces shall be thoroughly cleaned prior to installation of striping or markings.
10.All sign posts shall utilize break-away assemblies and fasteners per the Standards.
11.A field inspection of location and installation of all signs shall be performed by the City of Fort Collins Traffic Engineer. All discrepancies identified during
the field inspection must be corrected before the 2-year warranty period will begin.
12.The Developer installing signs shall be responsible for locating and protecting all underground utilities.
13.Special care shall be taken in sign location to ensure an unobstructed view of each sign.
14.Signage and striping has been determined by information available at the time of review. Prior to initiation of the warranty period,the City of Fort Collins
Traffic Engineer reserves the right to require additional signage and/or striping if the City of Fort Collins Traffic Engineer determines that an unforeseen
condition warrants such signage according to the MUTCD or the CDOT M and S Standards. All signage and striping shall fall under the requirements of
the 2-year warranty period for new construction (except fair wear on traffic markings).
15.Sleeves for sign posts shall be required for use in islands/medians. Refer to Chapter 14, Traffic Control Devices, for additional detail.
D. Storm Drainage Notes
1.The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite
drainage facilities shall be the responsibility of the property owner(s).
2.Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must by submitted to
and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the
release of a certificate of occupancy for single family units. For commercial properties, certification shall by submitted to the Stormwater Utility
Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development
Agreement.
E. Utility Notes
1.All waterline and sanitary sewer construction shall conform to the City of Fort Collins Utility standards and specifications current to date of construction.
2.The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the water utility.
3.Water mains shall be poly-wrapped D.I.P, or PVC with tracer wire.
4.HDPE pipe may be used for 1-1/2 and 2 inch water services. The pipe shall meet the standards of AWWA 901, NSF Standard 61 and ASTM. The
HDPE pipe shall be SDR 9 having a pressure rating of 200 psi. Stiffeners shall be used at all fittings and connections.
F. Floodplain Notes
1.Portions of this property are located in the Cityregulated, 100year Canal Importation floodplain/floodway as well as the FEMA Regulated Spring Creek
100year floodplain/floodway. Any development within the floodplain must comply with the safety regulations of Chapter 10 of City Municipal Code. The
Developer shall obtain a Floodplain Use Permit from the City of Fort Collins and pay all applicable floodplain use permit fees prior to commencing any
construction activity (building of structures, grading, fill, detention ponds, bike paths, parking lots, utilities, landscaped areas, flood control channels, etc.)
within the City of Fort Collins floodplain limits as delineated on the Final Subdivision Plat
2.“Any construction activities, nonstructural development (bridges, sidewalks, culverts, vegetation, curbcuts, grading, etc.) in the regulatory floodway must
be preceded by a NoRise Certification, which must be prepared by a professional engineer licensed in the State of Colorado.
3.No storage of materials or equipment shall be allowed in the floodway, whether temporary (during construction) or permanent.
4.Any pedestrian bridges in the floodway that are not able to pass the 100 year flow are required to be “breakaway” and tethered.
C 100CONSTRUCTION NOTESGENERAL &2
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 43
V.P.
CABLE
F.O.
HY DVAULT
ELEC
VAULT
ELECVAULT
ELEC
T
E
S
S
MH
S
SSS
S
S
T S
H2O
TRAFFIC
VAULTT SVAULT
ELEC
S
VAULT
ELEC
VAULT
ELEC
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
ELEC
CONTROL
IRR
CONTROL
IRR
IRR W
V.P.
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
S
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
HY DS S
15" SS18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS
21" SS
21" SS21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS
8
"
S
S
8" SS 8" SS
8" SS
8" SS8" SS/ / / / / / / /EEEEEEEEEETTTTTTTTGGGGGGGGGGGWW W W W W W W
12" W12" W12" W12" W12" W12" WEFOEEEEEEEEEGGGGGGXXXXXXXXXXX30" W30" W30" W30" W30" W30" W30" W36" W36" W36" WFDC
FS E
E
E E
U
D
U
D
U
DUDUD
UD
UD UD UD UD UDSSWWW
S
S
UDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDD
F.O.
D
S
S
HY DMH
S
HY DMM
MH
ELEC
/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /XX30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W
XXXXXXXXXXXXSTSTSTSTSTSS
30" W
WINNE GRANT R/JOHNELLE S
1821 WALLENBERG DR
ERIKSEN CHRISTOPHER M
1825 WALLENBERG DR
MCCOY JOHN H/SHERRY P
1900 S SHIELDS ST
HILL POND CONDOMINIUMS
S
SSSSSSSSSSSSSS2
1
"
S
S
2
1
"
S
S
2
1
"
S
S
EXISTING 8" WATERLINE
EXISTING 21" CLAY
SANITARY SEWER
EXISTING 18" CLAY
SANITARY SEWER
EXISTING 8"
SANITARY SEWER
TO BE RELOCATED
EXISTING 12" WATERLINE
EXISTING 21" CLAY
SANITARY SEWER
EXISTING 30"
WATERLINE
FEMA 100-YR
HIGH RISK
FLOOD FRINGE
LANDMARK
APARTMENTS
TREES TO BE
REMOVED (TYP.)
EXIST
I
N
G
S
P
R
I
N
G
C
R
E
E
K
T
R
A
I
LS SHIELDS ST.HOBBIT ST.
CITY OF FORT COLLINS
100-YR FLOODPLAIN
FEMA 100-YR HIGH RISK
FLOOD FRINGE
EXISTING
UNDERDRAIN
EXISTING 40' ROW
EXISTING 40' ROWWALLENBERG DR
.
EXISTING 5' SIDEWALK
36' FL-FL
EXISTING
IRRIGATION
SERVICE
EXISTING FENCE TO
BE REMOVED
EXISTING12"
WATERLINE
40' UTILITY EASEMENT
TO BE VACATED
24' UTILITY &
ACCESS
EASEMENT TO BE
VACATED
28' UTILITY &
ACCESS EASEMENT
TO BE VACATED
28' UTILITY
EASEMENT TO BE
VACATED
15' UTILITY
EASEMENT TO BE
VACATED
40' UTILITY EASEMENT
TO BE VACATED
20' UTILITY EASEMENT
TO BE VACATED
10' UTILITY
EASEMENT TO BE
VACATED
8' UTILITY
EASEMENT TO BE
VACATED
20' DRAINAGE
EASEMENT TO BE
VACATED
20' UTILITY &
ACCESS EASEMENT
TO BE VACATED
8' UTILITY
EASEMENT TO
BE VACATED
15' UTILITY
EASEMENT TO
BE VACATED
40' UTILITY
EASEMENT TO
BE VACATED
8' UTILITY
EASEMENT TO BE
VACATED
8' UTILITY
EASEMENT TO
BE VACATED
DRAINAGE EASEMENT
REC. NO. 20200015504
20' UTILITY
EASEMENT TO
BE VACATED
120' DRAINAGE EASEMENT
TO BE VACATED
REC. NO. 87043454
25' TEMPORARY
CONSTRUCTION EASEMENT
TO BE VACATED
REC. NO. 90019873
80' DRAINAGE EASEMENT
TO BE VACATED
REC. NO. 87043454
15' SLOPE EASEMENT
TO BE VACATED
REC. NO. 90019873
28' UTILITY &
ACCESS EASEMENT
TO BE VACATED
EXISTING 8"
SANITARY SEWER
TO BE RELOCATED
EXISTING
UNDERDRAIN
54' ROW TO
BE VACATED
EXISTING ELECTRIC
VAULT (TYP.)EXIST
ING
8
'
TRA
IL
EXISTING CANAL
IMPORTATION
SPRIN
G
C
R
E
E
K
EASEMENT TO
BE VACATED
EXISTING SANITARY
SEWER MH
FEMA 100-YR
FLOODWAY
CITY OF FORT COLLINS
100-YR FLOODWAY
EXISTING
IRRIGATION METER
TO BE RELOCATED
W STUART ST.EXISTING PAVEMENT
TO BE REMOVED
EXISTING HOBBIT STREET ASPHALT
TO BE MILLED & OVERLAYED
PER CITY STANDARDS
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 43
C 200DEMOLITION PLANEXISTING CONDITIONS &3
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
NORTH
( IN FEET )
1 inch = ft.
Feet06060
60
120 180
EXISTING ELECTRIC E
LEGEND:
G
T
EXISTING STORM SEWER
EXISTING TELEPHONE
EXISTING GAS
EXISTING IRRIGATION BOX
EXISTING GAS METER
EXISTING TELEPHONE PEDESTAL
EXISTING TREES (TO REMAIN)
FIELD SURVEY BY:
SUBSURFACE EXPLORATION BY:
NOTES:
EXISTING SANITARY SEWER SS
EXISTING WATER W
EXISTING FENCE X
EXISTING WATER METER
EXISTING FIRE HYDRANT
EXISTING ELECTRIC VAULT
PROJECT BOUNDARY
EXISTING RIGHT-OF-WAY
EXISTING MAJOR CONTOUR
EXISTING MINOR CONTOUR
VAULT
ELEC
CONTROL
IRR
EXISTING TREES (TO BE REMOVED)
EXISTING CABLE CTV
EXISTING FIBER OPTIC FO
1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL,
REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL.
3.CONTRACTOR IS ENCOURAGED TO PERFORM DEMOLITION IN A MANNER THAT
MAXIMIZES SALVAGE, RE-USE, AND RECYCLING OF MATERIALS. THIS INCLUDES
APPROPRIATE SORTING AND STORING. IN PARTICULAR, DEMOLISHED CONCRETE,
ASPHALT, AND BASE COURSE SHOULD BE RECYCLED IF POSSIBLE.
4.ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE.
5.CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING
SITE SURVEY.
EXISTING OVERHEAD UTILITY OHE
Intermill Land Surveying, Inc.Northern Engineering Services, Inc.
Company Project No. P-11-6963 Company Project No. 838-016
Date: April 2011 Date: July 2015
King Surveyors
Company Project No. 20190806
Date: January 2020
Earth Engineering Consultants, LLC
Geotechnical Exploration Report Shields Mixed Use Development South of Hobbit
Street, East of South Shields Street.
Fort Collins, CO.
EEC Project No. 1152075
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
MHUDEE
U
D
U
D
U
DUDUD
UD
UD UD UD UD UD UD
S
S
UDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDD
D
MH
MM
MH
/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /XXXXXXXXXXXXXXXXXSTSTSTSTSTSTSTWINNE GRANT R/JOHNELLE S
1821 WALLENBERG DR
ERIKSEN CHRISTOPHER M
1825 WALLENBERG DR
MCCOY JOHN H/SHERRY P
1900 S SHIELDS ST
HILL POND CONDOMINIUMS
SSSSSSSSSSSSSSSSUDUDUDUD
UD
FDC
FDC FDCFDCFDC FDC
FDC
FDC
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBXXXBBBBBBBBBXXXXXXXIP
IP
IP
IP
IP
IP
IP
IP
IP
IP
IP
OP
SF
SFSFSFSFRS
SF
RS
RS
RS
RS RS
RS
RS
RS
RS
RS
VTC
VTC
RS
SF
CWA
LOT 1
TRACT B
TRACT A
TRACT C
LOT 1
LOT 1
SPRI
N
G
C
R
E
E
K CANAL IMPORTATIONSS
IP
HOBBIT ST
HOBBIT STEXISTING SIDEWALKEXISTING SIDEWALKIP
IP
OP
RS
RS
IP
IP
IP IP
DETENTION
POND 2
DETENTION
POND 1
IP
IP
IP
IP
RS
SW SW
SW
SW
PROPOSED 4'
CONCRETE PAN PROPOSED 4'
CONCRETE PAN
PROPOSED 4'
CONCRETE PAN
PROPOSED 4'
CONCRETE PAN
PROPOSED 4'
CONCRETE PAN
PROPOSED 6'
CONCRETE PAN
PROPOSED 4'
CONCRETE PAN
PROPOSED 4'
CONCRETE PAN
PROPOSED 4'
CONCRETE PAN
PROPOSED
STORM DRAIN
PROPOSED 2'
CONCRETE PAN
PROPOSED 2'
CONCRETE PAN
PROPOSED 2'
CONCRETE PAN
PROPOSED
RAIN GARDEN
PROPOSED 4'
CONCRETE PAN
PROPOSED OUTLET
STRUCTURE
PROPOSED 2'
SIDEWALK
CHASE
PROPOSED 2'
SIDEWALK CHASE
PROPOSED 8"
STORM CULVERTS
PROPOSED 8"
STORM CULVERTS
PROPOSED 12"
STORM CULVERTS
PROPOSED 2'
SIDEWALK CHASE
FEMA 100-YR
HIGH RISK
FLOOD FRINGE
CITY OF FORT COLLINS
100-YR FLOODPLAIN
PROPOSED 2'
CONCRETE PAN
PROPOSED 2'
CONCRETE PAN
PROPOSED 2'
CONCRETE PAN
RAIN GARDEN
BIOMEDIA AREA
PROPOSED 4'
SIDEWALK
CULVERT
PROPOSED 4'
SIDEWALK
CULVERT
PROPOSED 2'
CONCRETE PAN
FEMA 100-YR
FLOODWAY
CITY OF FORT COLLINS
100-YR FLOODWAY
PROPOSED 2'
SIDEWALK CHASE
STORM DRAIN 1
SEE SHEET C 620
STORM DRAIN 1-8
SEE SHEET C 622
STORM DRAIN 1-9
SEE SHEET C 622
STORM DRAIN 4
SEE SHEET C 624
STORM DRAIN 4-4B
SEE SHEET C 624 STORM DRAIN 4-4A
SEE SHEET C 624
STORM DRAIN 5
SEE SHEET C 625
STORM DRAIN 5-2
SEE SHEET C 625
STORM DRAIN 2
SEE SHEET C 623
PROPOSED STORMTECH
CHAMBERS
STORM DRAIN 3
SEE SHEET C 623
STORM DRAIN 6
SEE SHEET C 626
PROPOSED
STORMTECH
CHAMBERS
PROPOSED 2'
SIDEWALK CHASE
STORM DRAIN 1-5
SEE SHEET C 621
STORM DRAIN 1-6
SEE SHEET C 621
SS
SS
SS
SS
SS
FOREBAY
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 43
C 300PLANEROSION CONTROL4
( IN FEET )
0
1 INCH = 60 FEET
60 60 120 180
NORTH
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
LEGEND:
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPOSED STORM INLET
TEMPORARY BMP'S
SEEDING AND MULCHING MU
CONCRETE WASHOUT AREA CWA
RSROCK SOCK
OUTLET PROTECTION OP
SILT FENCE SF SF
1.THE LOCATION OF EROSION CONTROL MEASURES HAS BEEN SHOWN FOR
REFERENCE ONLY. THE CONTRACTOR MAY ALTER THE NUMBER OR LOCATION
OF THE EROSION CONTROL MEASURES AS REQUIRED.
2.ALL OFF-SITE AREAS DISTURBED DURING CONSTRUCTION SHALL BE
RESEEDED WITH A DRYLAND SEED MIX, AS SPECIFIED IN THE CITY OF
LOVELAND STORMWATER SPECIFICATION SECTION 02377, PART 3, TABLE 1.
3.TOTAL DISTURBED AREA OF CONSTRUCTION = 5.91 ACRES
4.SWMP ADMINISTRATOR:
Person ________________________________
Company ________________________________
Address ________________________________
Phone ________________________________
5.CONTRACTOR TO PROVIDE VEHICLE TRACKING CONTROL FOR CONCRETE
WASHOUT AREA IF ACCESS IS OFF PAVEMENT.
GENERAL NOTES:
1.IT SHOULD BE NOTED THAT ANY EROSION CONTROL PLAN SERVES ONLY AS A
GUIDELINE TO THE CONTRACTOR. STAGING AND/OR PHASING OF BEST
MANAGEMENT PRACTICES (BMPs) IS EXPECTED. ADDITIONAL AND/OR DIFFERENT
BMPs FROM THOSE ORIGINALLY DEPICTED MAY BE NECESSARY DURING
CONSTRUCTION DUE TO CHANGING SITE CONDITIONS OR AS REQUIRED BY LOCAL
AUTHORITIES.
2.THIS EROSION CONTROL PLAN IS SCHEMATIC IN NATURE. AS SUCH, GRAPHICAL
SYMBOLS MAY NOT BE TO SCALE, NOR ARE THEY NECESSARILY SHOWN IN THEIR
EXACT LOCATION.
3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL PERMITTING (CITY, STATE
DISCHARGE PERMIT, ETC.) AND COMPLIANCE WITH GOVERNING AUTHORITIES. IT
SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR (OR PERMIT HOLDER) TO
ENSURE EROSION CONTROL MEASURES ARE PROPERLY MAINTAINED AND
FOLLOWED.
4.CONTRACTOR SHALL IMPLEMENT THE APPROPRIATE EROSION CONTROL MEASURES
ACCORDING THE THE CONSTRUCTION SEQUENCING AND LEVEL OF SITE
STABILIZATION.
5.CONTRACTOR SHALL IMPLEMENT APPROPRIATE INLET PROTECTION FOR ALL
STORMWATER FACILITIES UNTIL SITE IS FULLY STABILIZED.
6.CONTRACTOR SHALL IMPLEMENT APPROPRIATE INLET PROTECTION FOR
DOWNSPOUT CONNECTIONS, TO THE STORM DRAIN SYSTEM, UNTIL CONNECTION IS
ESTABLISHED WITH DOWNSPOUT.
7.INLET PROTECTION SHALL BE ADAPTED, AS NECESSARY, TO THE SURROUNDING
SURFACE TYPE AND CONDITION (i.e., STAKE-DRIVEN WATTLES FOR BARE SOIL,
GRAVEL SOCKS FOR PAVEMENT, ETC.)
8.CONTRACTOR IS RESPONSIBLE FOR STABILIZING ALL SLOPES, PARTICULARLY
THOSE STEEPER THAN 6:1. CRIMP MULCHING, HYDRO MULCHING, EROSION MATS,
TEMPORARY IRRIGATION, AND ADDITIONAL WATTLES OR SILT FENCING MAY BE
NECESSARY TO ESTABLISH VEGETATIVE COVER AND STABILIZE THE SLOPE.
9.ADDITIONAL WATTLES, SILT FENCE, OR OTHER MEASURES, MAY BE NECESSARY TO
INSURE THAT EACH BUILDING PAD IS STABILIZED THROUGHOUT CONSTRUCTION. AT
NO TIME SHALL SEDIMENT BE ALLOWED TO CROSS THE PUBLIC SIDEWALKS.
10.CONTRACTOR SHALL IMPLEMENT APPROPRIATE PERIMETER PROTECTION FOR
AREAS DIRECTING DRAINAGE OFFSITE. PERIMETER PROTECTION SHALL BE
ADAPTED, AS NECESSARY, TO THE SURROUNDING SURFACE TYPE AND CONDITION
(i.e., STAKE-DRIVEN SEDIMENT CONTROL LOGS OR SILT FENCE FOR BARE SOIL, SAND
BAGS OR GRAVEL SOCKS FOR PAVEMENT, ETC.)
11.FUELING FACILITIES SHALL BE LOCATED AT LEAST ONE HUNDRED (100) FEET FROM
NATURAL BODY OF WATER, WETLAND, NATURAL DRAINAGE WAY OR MANMADE
DRAINAGE WAY. THE FUEL TANKS AND FUELING AREA MUST BE SET IN A
CONTAINMENT AREA THAT WILL NOT ALLOW A FUEL SPILL TO DIRECTLY FLOW, SEEP,
RUN OFF, OR BE WASHED INTO A BODY OF WATER, WETLAND OR DRAINAGE WAY.
12.CONSTRUCTION WASTE STORAGE (DUMPSTERS) AND PORTABLE SANITATION UNITS
(CONSTRUCTION TOILETS) SHALL BE LOCATED AT LEAST FIFTY (50) FEET FROM ANY
STORMWATER INLET, WETLAND, OR DRAINAGE WAY. SAID FACILITIES MUST BE SET
IN A CONTAINMENT AREA THAT WILL NOT ALLOW POLLUTANTS TO DIRECTLY FLOW,
SEEP, RUN OFF, OR BE WASHED INTO A BODY OF WATER, WETLAND OR DRAINAGE
WAY. DUMPSTERS SHALL BE LOCATED ON FLAT, STABLE GROUND, AND
CONSTRUCTION TOILETS SHALL BE STAKED DOWN.
13.THE CONTRACTOR AND ALL SUBCONTRACTORS WILL COOPERATE WITH THE CITY'S
CONSTRUCTION INSPECTORS BY CEASING OPERATIONS WHEN WINDS ARE OF
SUFFICIENT VELOCITY TO CREATE BLOWING DUST WHICH, IN THE INSPECTOR'S
OPINION, IS HAZARDOUS TO THE PUBLIC HEALTH AND WELFARE.
14.WHERE SEASONAL CONSTRAINTS (E.G., DURING SUMMER AND WINTER MONTHS)
INHIBIT PERMANENT SEEDING OPERATIONS, DISTURBED AREAS WILL BE TREATED
WITH MULCH AND MULCH TACKIFIER OR OTHER MATERIALS APPROVED BY EROSION
CONTROL STAFF TO PREVENT EROSION.
15.SEE LANDSCAPE PLANS FOR ADDITIONAL INFORMATION ON PLANTING,
REVEGETATION, HARDSCAPE AND OTHER PERMANENT SITE STABILIZATION
METHODS.
17.SLOPE PROTECTION SHALL BE PROVIDED FOR DISTURBED AREAS STEEPER THAN
6:1. SLOPE PROTECTION CAN BE ACCOMPLISHED THROUGH SLOPE TERRACING
USING A TRACKED VEHICLE, WINDROWING, HYDROMULCHING, EROSION CONTROL
FABRIC, OR ANY METHOD AS APPROVED BY THE ENGINEER OR INSPECTOR.
EROSION CONTROL NOTES:
INLET PROTECTION IP
VEHICLE TRACKING CONTROL PAD VTC
SCOURSTOP SS
TABLE OF CONSTRUCTION SEQUENCE AND BMP APPLICATION
Project: THE QUARRY BY WATERMARK
CONSTRUCTION PHASE MOBILIZATION DEMOLITION GRADING
BEST MANAGEMENT PRACTICES (BMPS)
STRUCTURAL "INSTALLATION"
Silt Fence Barriers *
Straw Wattles *
Inlet Protection *
Vegetative
Temporary Seeding Planting
Mulching / Sealant
Permanent Seeding Planting
Sod Installation
Rolled Products : Netting / Blankets / Mats
Concrete Washout Area*
Rock Socks *
UTILITIES
INSTALLATION
FLAT WORK
INSTALLATION
VERTICAL
INSTALLATION LANDSCAPE DEMOBILIZATION
Vehicle Tracking Pad *
* All Temporary BMPs to be Removed once Construction is Complete
Any prior inlets that could use protecting
Any prior inlets that could use protecting
Anytime the site will sit dormant longer than 30 Days
Anytime the site will sit dormant longer than 30 Days
Anytime the site will sit dormant longer than 30 Days
SWSTRAW WATTLE
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 43
C 301DETAILSEROSION CONTROL5
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
SF
1 OUTLET PROTECTION
2 CONCRETE WASHOUT AREA
3 TYPICAL ROCK SOCK
4 VEHICLE TRACKING CONTROL PAD
5 SILT FENCE
VTC
ROCK SOCK SECTION ROCK SOCK PLAN
ROCK SOCK JOINTING
GRADATION TABLE
SIEVE SIZE
MASS PERCENT
PASSING SQUARE
MESH SIEVES
NO. 4
2"100
1-1/2"90-100
1"20-55
3/4"0-15
3/8"0-5
MATCHES SPECIFICATIONS FOR NO. 4 COARSE AGGREGATE FOR
CONCRETE PER AASHTO M43. ALL ROCK SHALL BE FRACTURED FACE,
ALL SIDES
RS
CWA
AA
PLAN VIEW
SECTION A-A
2:1
OP
WQCV
9 CURB INLET PROTECTION
AT PIPE OUTLET AREAS OF STREAMS AND
DRAINAGE CHANNELS - DETAIL A
IN DIVERSION DITCH OR SMALL DITCH DRAINAGE WAY - DETAIL B
OUTSIDE OF STREAMS AND DRAINAGE CHANNELS - DETAIL C
ANCHOR DETAILS
PERIMETER ANCHOR TRENCH
JOINT ANCHOR TRENCH
INTERMEDIATE ANCHOR TRENCH
OVERLAPPING JOINT
WOOD STAKE DETAIL
MINIMUM THICKNESS 1"
USE 2x4 MATERIAL FOR STAKES
JOINT ANCHOR
TRENCH, TYP.
PERIMETER
ANCHOR
TRENCH, TYP.
TOP OF
CHANNEL BANK
TYPE OF BLANKET AS INDICATED IN PLAN VIEW, IN ALL DISTURBED AREAS OF
STREAMS AND DRAINAGE CHANNELS TO DEPTH "D" ABOVE CHANNEL INVERT.
BLANKET SHALL GENERALLY BE ORIENTED PARALLEL TO FLOW DIRECTION.
STAKING PATTERN SHALL MATCH BLANKET TYPE.
UNDISTURBED
SOIL
TYPE OF BLANKET,
INDICATED IN PLAN VIEW PER MANUFACTURER SPEC. OR TYPE 2 OR 3 STAKING
(MATCH SPECIFIED BLANKET TYPE) SEE THE STAKING
PATTERNS DETAIL ON NEXT SHEET
PERIMETER
ANCHOR TRENCH, TYP.
JOINT ANCHOR TRENCH, TYP.
COMPACTED
SUBGRADE
1
>3
THE BLANKET SHALL
BE EXTENDED TO THE
TOP OF CHANNEL
"D" 6"TOPSOIL"M"
OVERLAPPING JOINT, SEE
DETAIL ON THIS SHEET
STAGGER
OVERLAPS
PERIMETER ANCHOR TRENCH
SEE DETAIL ON THIS SHEET
PER MANUFACTURER SPEC.
OR TYPE 1 STAKING SEE
THE STAKING PATTERN
DETAIL ON NEXT SHEET
BLANKET SHALL BE
100% STRAW MIN.
DIVERSION DITCH
TYPICALLY AT
TOP OF SLOPE
6"TOPSOIL6" MIN.
(TYP.)
3" MIN.
(TYP.)
SINGLE EDGE
EROSION CONTROL
BLANKET (TYP.)
COMPACTED
BACKFILL (TYP.)
STAKE (TYP.)
TWO EDGES OF
TWO ADJACENT
ROLLS
LOOP FROM
MIDDLE OF
ROLL
FLOW 6"
3" MIN. 12"MIN. STAKING PATTERNS
SHALL BE IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATION. IF NO MANUFACTURER'S
SPECIFICATION IS AVAILABLE USE THE ACCEPTABLE STAKING PATTERN (AS SHOWN ABOVE)
PERIMETER ANCHOR
TRENCH OR JOINT
ANCHOR TRENCH, TYP.
STRAW-COCONUT
COCONUT OR EXCELSIOR
STRAW
ROLL WIDTH
"W" (TYP.)6'3'1/2 "W"
1/2 "W"
1/2 "W"
1/2 "W"
1/2 "W"4'3'2'ECB
EROSION CONTROL BLANKET TYPE
TYPE
STRAW*
STRAW-COCONUT
EXCELSIOR
COCONUT
CONTENT
-
30% MIN.
-
STRAW
CONTENT
100%
-
NETTING MIN.
DOUBLE/NATURAL
100%
-
-
EXCELSIOR
CONTENT
COCONUT --100%
* FOR OUTSIDE OF STREAMS AND DRAINAGE CHANNELS
DOUBLE/NATURAL
DOUBLE/NATURAL
DOUBLE/NATURAL
MAX.70%
IP
TURF REINFORCEMENT MAT - SCOUR STOP7
36" ANCHOR STRAP
BULLET ANCHOR
RECESSED LOCK
WASHER
TRANSITION MAT
TURF
REINFORCEMENT
MAT
ANCHOR PATTERN
ANCHOR ILLUSTRATION
MAX. 1"-2" DROP
FROM CULVERT FLOWLINE
ONTO SCOURSTOP MATS
PROFILE VIEW
SECTION VIEW AA
OUTLET AND CHANNEL SCOUR PROTECTION
(TRANSITION MATS)
DIRECTION OF FLOW
TURF REINFORCEMENT MAT
WIDTH OF
PROTECTION
LENGTH OF PROTECTION
D
D= CULVERT DIAMETER
TRAN
SI
TI
O
N
M
A
T
S
SOIL
C
O
V
E
R
A
A
CULVERT OUTLET PROTECTION - PLAN VIEW
INSTALL ANCHORS PER SCOURSTOP INSTALLATION GUIDELINES
MINIMUM DEPTH 24" IN COMPACTED, COHESIVE SOIL.
MINIMUM DEPTH 30" IN LOOSE, SANDY, OR WET SOIL
EXTRA ANCHORS AS NEEDED TO SECURE MAT TIGHTLY OVER SOIL
COVER
ABUT TRANSITIONS MATS TO END OF CULVERT OR CULVERT APRON.
ADJACENT MATS ABUT TOGETHER LATERALLY AND LONGITUDINALLY.
MINIMUM 8 ANCHORS PER MAT.
EXTRA ANCHORS AS NEEDED FOR LOOSE OR WET SOILS.
PROTECT BARE/ DISTURBED DOWNSTREAM
SOILS FROM EROSION WITH APPROPRIATE
SOIL COVER.
NOTE:
1.SCOUR STOP MAT PRODUCT UTILIZED FOR TURF REINFORCEMENT MAT DIMENSIONS. OTHER TURF REINFORCEMENT MAT
PRODUCTS EQUAL TO OR BETTER ALLOWED WITH APPROVAL OF THE ENGINEER AND CITY.
2.SEEDING AT OUTFALL OF STORM SEWER SHALL BE COMPLETED PRIOR TO INSTALLATION OF TURF REINFORCEMENT MAT.
SS
SEEDING TO OCCUR
PRIOR TO INSTALLATION
IP
FL
O
W
3'-4'
ADJACENT ROLLS SHALL
TIGHTLY ABUT
W1 NOTES:
INSTALLATION:
WHEN INSTALLING RUNNING LENGTHS OF WATTLES, BUTT
THE SECOND WATTLE TIGHTLY AGAINST THE FIRST, DO
NOT OVERLAP THE ENDS. STAKE THE WATTLES AT EACH
END AND FOUR FOOT ON CENTER. FOR EXAMPLE:
A 25 FOOT WATTLE USES 6 STAKES
A 20 FOOT WATTLE USES 5 STAKES
A 12 FOOT WATTLE USES 4 STAKES
STAKES SHOULD BE DRIVEN THROUGH THE MIDDLE OF
THE WATTLE. LEAVING 2 - 3 INCHES OF THE STAKE
PROTRUDING ABOVE THE WATTLE. A HEAVY SEDIMENT
LOAD WILL TEND TO PICK THE WATTLE UP AND COULD
PULL IT OFF THE STAKES IF THEY ARE DRIVEN DOWN TOO
LOW. IT MAY BE NECESSARY TO MAKE A HOLE IN THE
WATTLE WITH A PICK END OF YOUR MADDOX IN ORDER TO
GET THE STAKE THROUGH THE STRAW. WHEN STRAW
WATTLES ARE USED FOR FLAT GROUND APPLICATIONS,
DRIVE THE STAKES STRAIGHT DOWN; WHEN INSTALLING
WATTLES ON SLOPES, DRIVE THE STAKES
PERPENDICULAR TO THE SLOPE.
DRIVE THE FIRST END STAKE OF THE SECOND WATTLE AT
AN ANGLE TOWARD THE FIRST WATTLE IN ORDER TO HELP
ABUT THEM TIGHTLY TOGETHER. IF YOU HAVE DIFFICULTY
DRIVING THE STAKE INTO EXTREMELY HARD OR ROCKY
SLOPES, A PILOT BAR MAY BE NEEDED TO BEGIN THE
STAKE HOLE.
1"x 1" WOOD STAKES
18"-24"
BAILING WIRE OR
NYLON ROPE
WATTLE "A"WATTLE "B"
1'2'
TYP.
1'1'
W2 NOTES:
INSTALLATION:
STAKES SHOULD BE DRIVEN ACROSS
FROM EACH OTHER AND ON EACH
SIDE OF THE WATTLE. LEAVING 4"-6"
OF STAKE PROTRUDING ABOVE THE
WATTLE. BAILING WIRE OR NYLON
ROPE SHOULD BE TIED TO THE
STAKES ACROSS THE WATTLE.
STAKES SHOULD THEN BE DRIVEN
UNTIL THE BAILING WIRE OR NYLON
ROPE IS SUFFICIENTLY SNUG TO THE
WATTLE.
WHEN INSTALLING RUNNING LENGTHS
OF WATTLES, TO PREVENT SHIFTING,
BUTT THE SECOND WATTLE TIGHTLY
AGAINST THE FIRST. DO NOT
OVERLAP THE ENDS. STAKES
SHOULD BE DRIVEN 1 FT. FROM END,
ACROSS FROM AND ON EACH SIDE OF
WATTLE LEAVING 4"-6" OF STAKE
PROTRUDING ABOVE THE WATTLE.
BAILING WIRE OR NYLON ROPE
SHOULD BE TIED TO STAKES IN AN
HOUR GLASS FORMATION (FRONT TO
BACK OF WATTLE "A", ACROSS TO
FRONT OF WATTLE "B", ACROSS TO
BACK AND BACK TO FRONT OF
WATTLE "A"). STAKES SHOULD THEN
BE DRIVEN IN UNTIL BAILING WIRE OR
NYLON ROPE IS SUFFICIENTLY SNUG
TO THE WATTLE.
W1 & W2 INSTALLATION NOTES:
1. THE LOCATION AND LENGTH OF WATTLE IS DEPENDENT ON THE CONDITIONS OF EACH SITE.
2. WATTLES SHALL BE INSTALLED PRIOR TO ANY LAND-DISTURBING ACTIVITIES.
3. WATTLES SHALL CONSIST OF STRAW, COMPOST, EXCELSIOR, OR COCONUT FIBER.
4. NOT FOR USE IN CONCENTRATED FLOW AREAS.
5. THE WATTLES SHALL BE TRENCHED INTO THE GROUND A MINIMUM OF TWO (2) INCHES.
6. WATTLES SHALL BE INSTALLED PER MANUFACTURERS SPECIFICATIONS.
7. ON SLOPES, WATTLES SHOULD BE INSTALLED ON CONTOUR WITH A SLIGHT DOWNWARD ANGLE AT THE END OF THE ROW IN ORDER TO
PREVENT PONDING AT THE MID SECTION.
8. RUNNING LENGTHS OF WATTLES SHOULD BE ABUTTED FIRMLY TO ENSURE NO LEAKAGE AT THE ABUTMENTS.
9. SPACING - DOWNSLOPE:
VERTICAL SPACING FOR SLOPE INSTALLATIONS SHOULD BE DETERMINED BY SITE CONDITIONS. SLOPE GRADIENT AND SOIL TYPE ARE THE
MAIN FACTORS. A GOOD RULE OF THUMB IS:
1:1 SLOPES = 10 FEET APART
2:1 SLOPES = 20 FEET APART
3:1 SLOPES = 30 FEET APART
4:1 SLOPES = 40 FEET APART, ETC.
HOWEVER, ADJUSTMENTS MAY HAVE TO BE MADE FOR THE SOIL TYPE: FOR SOFT, LOAMY SOILS - ADJUST THE ROWS CLOSER
TOGETHER; FOR HARD, ROCKY SOILS - ADJUST THE ROWS FURTHER APART. A SECONDARY WATTLE PLACED BEHIND THE ABUTMENT OF TWO
WATTLES IS ENCOURAGED ON STEEP SLOPES OR WHERE JOINTS HAVE FAILED IN THE PAST.
10. STAKING: THE CITY RECOMMENDS USING WOOD STAKES TO SECURE THE WATTLES. 1/2" TO 5/8" REBAR IS ALSO ACCEPTABLE. BE SURE TO
USE A STAKE THAT IS LONG ENOUGH TO PROTRUDE SEVERAL INCHES ABOVE THE WATTLE: 18" IS A GOOD LENGTH FOR HARD, ROCKY SOIL.
FOR SOFT LOAMY SOIL USE A 24" STAKE.
4"-6" ABOVE WATTLE AFTER BAILING WIRE
OR NYLON ROPE IS ATTACHED. STAKES
NEED TO BE TAMPED UNTIL WIRE/ROPE IS
SNUG WITH WATTLE.
1"x 1" WOOD STAKES
18"-24"
ENDS OF ADJACENT WATTLES
SHALL BE TIGHTLY ABUTTED
TO PREVENT SEDIMENT BYPASS
W2 NOTE:
ONLY WATTLES MADE WITH COCONUT
FIBERS SHALL BE USED WHEN
INSTALLATION COMES IN CONTACT WITH A
WATER BODY.
SW
STRAW WATTLE6
8 INLET PROTECTION
10 CURB INLET PROTECTION
Scourstop Schedule
Storm
Line
Pipe
Diameter
(in)
Velocity
(cfs)
Transition Mat
W x L
2 & 2A 24 5*8'x8'
3 24 9.90 8'x8'
4 24 3.21 8'x8'
6 24 2.32 8'x8'
/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /6' SIDEWALK
6' SIDEWALK6' SIDEWALK
9' SIDEWALK6' SIDEWALK
9' SIDEWALKS SHIELDS ST.HOBBIT ST.
6' SIDEWALKEXISTING SIDEWALKLOT 1
8.5'8.5'
8'
8'
8'
17'
9'8'9'
8'
9'
9'
8'
8'
8.5'
8.5'
8.5'
8.5'8.5'
5'
8'
8.5'8.5'
8.5'
17'
17'17'17'
8.5'
8.5'
17'
17'
21'
17'
16.5'
15.5'15.5'
17'17'17'
17'
8.5'
8.5'
8.5'
8.5'
17'
15'
15'
17'
26'
FL-FL
31'
FL-FL
26'
FL-FL
26'
FL-FL
26'
FL-FL
26'
FL-FL
20'
FL-FL
26' EMERGENCY ACCESS EASEMENT
26' EMERGENCY ACCESS EASEMENT
26' EMERGENCY ACCESS EASEMENT
31' EMERGENCY ACCESS EASEMENT
33' WATER EASEMENT 8' SIDEWALK9' SIDEWALK5' SIDEWALK6' SIDEWALK
5' SIDEWALK9' SIDEWALK5' SIDEWALK
16.5'
17'
8.5'
5'
8'
23'
26'
FL-FL
26' EMERGENCY ACCESS EASEMENT
4.5' SIDEWALK4.5' SIDEWALK
R15'
R25'
R15'
R3'R3'R3'R3'
R25'
R25'R75'
R7'
R7'R7'
R15'
R15'R15'R15'
R7'
R7'R3'
R7'
R7'
R15'
R10'
R15'
R7'
R15'
R7'
BLDG 6
BLDG 7
BLDG 2
BLDG 3
BLDG 4 BLDG 5
N:1448979.06
E:3113213.44
N:1449042.86
E:3113153.80
N:1449260.66
E:3113202.71
N:1449362.97
E:3113148.87
N:1449415.10
E:3113338.48
N:1449419.74
E:3113376.26
N:1449360.75
E:3113602.30
N:1449210.25
E:3113641.62
N:1449020.70
E:3113589.30
N:1449020.72
E:3113543.88
N:1449210.33
E:3113491.75
N:1449027.58
E:3113288.82
N:1449076.29
E:3113452.99
MATCH INTO EXISTING
SIDEWALK, CURB,
AND GUTTER
EXISTING RAMP TO BE
UPDATED TO CURRENT
CITY STANDARDS
EXISTING
STRIPING (TYP.)
EXISTING HOBBIT STREET ASPHALT
TO BE MILLED & OVERLAYED
PER CITY STANDARDS
P P
D
C
D
D
D
C
D
PP
D
D
D
P
2
2
2 2
2
2
2
2
2 2
2
2
2 2
2
2
2
1 1
1
1
1
1
1
2
2
2
4
4
2
5 5
5
5 5
5
6
TRASH
ENCLOSURE
66
5
5
5
5
66556
5 6
6
6
P
7
PROPOSED
LANDSCAPE
WALL
PROPOSED 30" VERTICAL
CURB & GUTTER
7
7
7
7
7
7
7
7
6
6
7
7
PROPOSED
LANDSCAPE
WALL
7
8
8
4
4 4 4 4
4
44
444
4 4
7
7 7
PROPOSED 2' PAN
w/ 6" CURBS
4
4 4 4PARKING
STOP (TYP.)
11
1
1
1
P
1 1
2
2
2
2
2 22
2
PROPOSED
LANDSCAPE
WALL
7
7
7
7
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 43
C 400PAVING PLAN6
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
NORTH
( IN FEET )
1 inch = ft.
Feet03030
30
60 90
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
1
SEE SHEET C 402 SEE SHEET C 401EASEMENTS
NOTES:
1.SEE DETAIL SHEETS FOR ADDITIONAL INFORMATION REGARDING CURBS AND PAVEMENT SECTIONS.
2.PAVEMENT MARKINGS SHALL BE PER CITY OF FORT COLLINS STANDARDS AND PROJECT SPECIFICATION
MANUAL.
3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE
CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF
FORT COLLINS STREET REPAIR STANDARDS.
4.ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS,
SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS
PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE
DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO
THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY.
5.ALL PUBLIC CONCRETE PAVING SHALL BE 6" THICK.
6.REFER TO SITE AND LANDSCAPE PLANS (BY OTHERS) FOR ADDITIONAL INFORMATION RELATED TO
DECORATIVE PAVING, HARDSCAPES, AND OTHER SITE AMENITIES.
7.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE CITYREGULATED, 100YEAR CANAL IMPORTATION
FLOODPLAIN/FLOODWAY AS WELL AS THE FEMA REGULATED SPRING CREEK 100YEAR
FLOODPLAIN/FLOODWAY. ANY DEVELOPMENT WITHIN THE FLOODPLAIN MUST COMPLY WITH THE SAFETY
REGULATIONS OF CHAPTER 10 OF CITY MUNICIPAL CODE. THE DEVELOPER SHALL OBTAIN A FLOODPLAIN
USE PERMIT FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE PERMIT FEES
PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES, GRADING, FILL,
DETENTION PONDS, BIKE PATHS, PARKING LOTS, UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL
CHANNELS, ETC.) WITHIN THE CITY OF FORT COLLINS FLOODPLAIN LIMITS AS DELINEATED ON THE FINAL
SUBDIVISION PLAT
8.ANY CONSTRUCTION ACTIVITIES, NONSTRUCTURAL DEVELOPMENT (BRIDGES, SIDEWALKS, CULVERTS,
VEGETATION, CURBCUTS, GRADING, ETC.) IN THE REGULATORY FLOODWAY MUST BE PRECEDED BY A
NORISE CERTIFICATION, WHICH MUST BE PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN THE
STATE OF COLORADO.
9.NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE FLOODWAY, WHETHER
TEMPORARY (DURING CONSTRUCTION) OR PERMANENT.
8.ANY PEDESTRIAN BRIDGES IN THE FLOODWAY THAT ARE NOT ABLE TO PASS THE 100 YEAR FLOW ARE
REQUIRED TO BE “BREAKAWAY” AND TETHERED.
9.CURVES AND LINES ARE MEASURED AT FLOWLINE, CENTERLINE OR EDGE OF WALK.
10.ATTACHED WALK WIDTHS ARE FROM FLOWLINES.
11.SINGLE POINT CURB TRANSITIONS ARE 6'.
12.SIGN PLACEMENT SHALL BE PER THE LATEST EDITION OF MUTCD REGARDLESS OF PLAN LOCATION.
13.ALL CURB & GUTTER CALLS ARE UNLESS OTHERWISE NOTED.
PROPOSED VERTICAL CURB & GUTTER
PROPERTY BOUNDARY
EXISTING LOT LINE
PROPOSED LOT LINE
ASPHALT PAVING
PROPOSED OUTFALL VERTICAL CURB & GUTTER
LEGEND:
PRIVATE CONCRETE FLATWORK
SITE SIGN LEGEND
SIGNAGE NOTE:
SIGN LOCATIONS SHOWN ARE
APPROXIMATE. FINAL LOCATION
MAY VARY.
RESERVED
PARKING
2
P
D
C
2
3
4
5
6
7
18" VERTICAL INFLOW CURB & GUTTER
18" FLUSH CURB
30" OUTFALL DRIVE-OVER CURB & GUTTER
18" VERTICAL OUTFALL CURB & GUTTER
PARALLEL ACCESS RAMP
DIRECTIONAL ACCESS RAMP
COMBINATION ACCESS RAMP
8
X' CONCRETE PAN
8
PUBLIC CONCRETE FLATWORK
HEAVY DUTY PRIVATE CONCRETE PAVING
P
FIRE LANE
1' SIDEWALK CHASE
2' SIDEWALK CHASE
X
2' CONCRETE TRICKLE PAN
1
2' CURB CUT
1
C 402 C 403
C 401C 400
MHX/ / / / / / / /SUDUDUDE
E
E
E
E
E
E E E E
UD
UDUDU
D
U
D
U
D
U
D
U
D
U
D
U
D
U
D
U
DSSSSSSSS
S
S
UDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
MM
MHXXXXXXX XXXXXXXXXXX7' SIDEWALK4' SIDEWALK
5' SIDEWALK 10' SIDEWALK6' SIDEWALK
WALLENBERG DR.11' SIDEWALK EXIST
ING
8
'
TRA
IL
TRACT ACANAL IMPORTATIONXXXXXXXXXXXXXXXXXX9'
9'
9'
8.5'
8.5'
8.5'
8.5'
17'
8.5'
17'
17'
8.5'
17'
8.5'
17'
17'
17'
8.5'
8.5'
8.5'
8.5'
8.5'
17'
17'
26'
FL-FL
26'
FL-FL 26' EMERGENCYACCESS EASEMENT26' EMERGENCY ACCESS EASEMENT
26'
FL-FL9' SIDEWALK9' SIDEWALK6' SIDEWALK8'15'
8'
17'
9' SIDEWALK
6' SIDEWALK
8.5'
21'26' EMERGENCYACCESSEASEMENT4' SIDEWALK7' SIDEWALK4' SIDEWALK24' ACCESS
EASEMENT4' SIDEWALKR15'
R25'
R15'R25'R3'
R3'
R3'
R25'
R3'
R15'
R25'R25'
BLDG 8
BLDG 18 BLDG 17
BLDG 16
BLDG 15
BLDG 14
BLDG 13
BLDG 12
BLDG 11
BLDG 10
BLDG 9
N:1449428.97
E:3113756.99
N:1449355.66
E:3113828.72
N:1449423.88
E:3113850.13
N:1449356.76
E:3113786.90
N:1449427.88
E:3113798.81
N:1449351.67
E:3113880.04 N:1449350.57
E:3113921.86
N:1449423.77
E:3113921.89
N:1449293.66
E:3113889.03
N:1449263.68
E:3113961.22
N:1449251.84
E:3113890.08
N:1449221.85
E:3113962.27
N:1449206.88
E:3113891.16
N:1449178.49
E:3113959.75
N:1449162.08
E:3113891.15
N:1449133.77
E:3113959.77
N:1449104.57
E:3113891.11
N:1449076.18
E:3113959.70
N:1449059.81
E:3113891.08
N:1449031.46
E:3113959.71
N:1449040.88
E:3113740.67
N:1449266.93
E:3113799.65
EXISTING SIDEWALK
CULVERT
FEMA 100-YR
HIGH RISK
FLOOD FRINGE
CITY OF FORT
COLLINS 100-YR
FLOODPLAIN
RAIN GARDEN
BIOMEDIA AREA
PROPOSED
LANDSCAPE
WALL (TYP.)
CITY OF FORT COLLINS
100-YR FLOODWAY
PROPOSED 2' PAN
w/ 6" CURBS
PROPOSED 2' PAN
w/ 6" CURBS
EXPOSE BACK
OF CURB
D
D
D
PROPOSED
DRIVE-WAY PER
LCUASS STANDARDS
D
P
D
D
D
D
D
2
2 2
2
2
2
2
2
2
2
2
2
2
1
1
3
3
5
6
6
6
6
6
5
6
6
5
5
5 56
6
5
5
7
7
8
4 4
4
4
4
6
44
6
6
4
4
PROPOSED
LANDSCAPE
WALL
P
1
1
2
2
2
2
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 43
( IN FEET )
0
1 INCH = 30 FEET
30 30 60 90
NORTH
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
RSEE SHEET C 400C 401PAVING PLAN7SEE SHEET C 403
EASEMENTS
NOTES:
1.SEE DETAIL SHEETS FOR ADDITIONAL INFORMATION REGARDING CURBS AND PAVEMENT SECTIONS.
2.PAVEMENT MARKINGS SHALL BE PER CITY OF FORT COLLINS STANDARDS AND PROJECT SPECIFICATION
MANUAL.
3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE
CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF
FORT COLLINS STREET REPAIR STANDARDS.
4.ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS,
SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS
PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE
DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO
THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY.
5.ALL PUBLIC CONCRETE PAVING SHALL BE 6" THICK.
6.REFER TO SITE AND LANDSCAPE PLANS (BY OTHERS) FOR ADDITIONAL INFORMATION RELATED TO
DECORATIVE PAVING, HARDSCAPES, AND OTHER SITE AMENITIES.
7.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE CITYREGULATED, 100YEAR CANAL IMPORTATION
FLOODPLAIN/FLOODWAY AS WELL AS THE FEMA REGULATED SPRING CREEK 100YEAR
FLOODPLAIN/FLOODWAY. ANY DEVELOPMENT WITHIN THE FLOODPLAIN MUST COMPLY WITH THE SAFETY
REGULATIONS OF CHAPTER 10 OF CITY MUNICIPAL CODE. THE DEVELOPER SHALL OBTAIN A FLOODPLAIN
USE PERMIT FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE PERMIT FEES
PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES, GRADING, FILL,
DETENTION PONDS, BIKE PATHS, PARKING LOTS, UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL
CHANNELS, ETC.) WITHIN THE CITY OF FORT COLLINS FLOODPLAIN LIMITS AS DELINEATED ON THE FINAL
SUBDIVISION PLAT
8.ANY CONSTRUCTION ACTIVITIES, NONSTRUCTURAL DEVELOPMENT (BRIDGES, SIDEWALKS, CULVERTS,
VEGETATION, CURBCUTS, GRADING, ETC.) IN THE REGULATORY FLOODWAY MUST BE PRECEDED BY A
NORISE CERTIFICATION, WHICH MUST BE PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN THE
STATE OF COLORADO.
9.NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE FLOODWAY, WHETHER
TEMPORARY (DURING CONSTRUCTION) OR PERMANENT.
8.ANY PEDESTRIAN BRIDGES IN THE FLOODWAY THAT ARE NOT ABLE TO PASS THE 100 YEAR FLOW ARE
REQUIRED TO BE “BREAKAWAY” AND TETHERED.
9.CURVES AND LINES ARE MEASURED AT FLOWLINE, CENTERLINE OR EDGE OF WALK.
10.ATTACHED WALK WIDTHS ARE FROM FLOWLINES.
11.SINGLE POINT CURB TRANSITIONS ARE 6'.
12.SIGN PLACEMENT SHALL BE PER THE LATEST EDITION OF MUTCD REGARDLESS OF PLAN LOCATION.
13.ALL CURB & GUTTER CALLS ARE UNLESS OTHERWISE NOTED.
PROPOSED VERTICAL CURB & GUTTER
PROPERTY BOUNDARY
EXISTING LOT LINE
PROPOSED LOT LINE
ASPHALT PAVING
PROPOSED OUTFALL VERTICAL CURB & GUTTER
LEGEND:
PRIVATE CONCRETE FLATWORK
SITE SIGN LEGEND
SIGNAGE NOTE:
SIGN LOCATIONS SHOWN ARE
APPROXIMATE. FINAL LOCATION
MAY VARY.
RESERVED
PARKING
2
P
D
C
2
3
4
5
6
7
18" VERTICAL INFLOW CURB & GUTTER
18" FLUSH CURB
30" OUTFALL DRIVE-OVER CURB & GUTTER
18" VERTICAL OUTFALL CURB & GUTTER
PARALLEL ACCESS RAMP
DIRECTIONAL ACCESS RAMP
COMBINATION ACCESS RAMP
8
X' CONCRETE PAN
8
PUBLIC CONCRETE FLATWORK
HEAVY DUTY PRIVATE CONCRETE PAVING
P
FIRE LANE
1' SIDEWALK CHASE
2' SIDEWALK CHASE
X
2' CONCRETE TRICKLE PAN
1
2' CURB CUT
1
C 402 C 403
C 401C 400
CABLE
F.O.
T FOFOF.O./ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /HILL POND CONDOMINIUMS
6' SIDEWALK
9' SIDEWALK
6' SID
E
W
A
L
K
10' SI
D
E
W
A
L
K
10' SIDEWALK
SPRIN
G
C
R
E
E
K
EXIS
TI
N
G
S
P
RI
N
G
C
R
E
E
K
T
R
AI
L
TRACT C
9'
9'8'
9'
9'
8'
9'
17'
17'17'
17'17'
17'
8.5'
17'
17'
31'
FL-FL
26'
FL-FL
26'
FL-FL
60'
FL-FL
31' EMERGENCY ACCESS EASEMENT
21'
33' WATER EASEMENT
9' SIDEWALK
21'
8'
21'
50' PUBLIC ACCESS &
TRAIL EASEMENT
26' EMERGENCY
ACCESS
EASEMENT
9'
9'
9'
9'21'
9'EXISTING ±10' LANEEXISTING ±6' BIKE LANE w/ BUFFEREXISTING ±10' LANEPROPOSED ±9' TURN LANEEXISTING ±10' LANEEXISTING ±10' LANEEXISTING ±10' LANEEXISTING ±10' TURN LANEEXISTING ±10' LANEEXISTING ±6' BIKE LANE w/ BUFFEREXISTING ±10' LANEEXISTING ±6' BIKE LANE w/ BUFFEREXISTING ±6' BIKE LANE w/ BUFFEREXISTING ±10' LANER25'
R25'R75'
R3'
MATCH EXISTING
CURB RETURN
R25'
MATCH EXISTING
CURB RETURN
R25'
R3'
R15'
R3'
R75'
R3'
BLDG 1
21'
9'EXISTING SIDEWALKEXISTING SIDEWALKEXISTING SIDEWALKN:1448856.83
E:3113142.11
N:1448927.96
E:3113410.66
N:1448979.06
E:3113213.44
TRACT B
PROPOSED 4'
SIDEWALK CULVERTNATURAL AREA
BUFFER
EXISTING RAMPS TO BE
UPDATED TO CURRENT
CITY STANDARDS
EXISTING RAMPS TO BE
UPDATED TO CURRENT
CITY STANDARDS
PROPOSED
STRIPING (TYP.)
EXISTING
STRIPING (TYP.)
INTERSECTION
STRIPING DETAILS
SEE SHEET INT1
PROPOSED MAINTENANCE
ACCESS PATH
D
C
D
D
D
D
D
D
PROPOSED STRIPING
D
2 2
2
2
2
1
1
1
1
1 1
4 4
2
4
4
4
2
66556
6
7
7
7
7
4 4 4
4
PARKING
STOP (TYP.)
PARKING
STOP (TYP.)
PARKING
STOP (TYP.)
1
2
PROPOSED
LANDSCAPE
WALL
7
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 43
NORTH
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
( IN FEET )
0
1 INCH = 30 FEET
30 30 60 90
C 402PAVING PLAN8
EASEMENTS
NOTES:
1.SEE DETAIL SHEETS FOR ADDITIONAL INFORMATION REGARDING CURBS AND PAVEMENT SECTIONS.
2.PAVEMENT MARKINGS SHALL BE PER CITY OF FORT COLLINS STANDARDS AND PROJECT SPECIFICATION
MANUAL.
3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE
CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF
FORT COLLINS STREET REPAIR STANDARDS.
4.ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS,
SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS
PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE
DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO
THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY.
5.ALL PUBLIC CONCRETE PAVING SHALL BE 6" THICK.
6.REFER TO SITE AND LANDSCAPE PLANS (BY OTHERS) FOR ADDITIONAL INFORMATION RELATED TO
DECORATIVE PAVING, HARDSCAPES, AND OTHER SITE AMENITIES.
7.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE CITYREGULATED, 100YEAR CANAL IMPORTATION
FLOODPLAIN/FLOODWAY AS WELL AS THE FEMA REGULATED SPRING CREEK 100YEAR
FLOODPLAIN/FLOODWAY. ANY DEVELOPMENT WITHIN THE FLOODPLAIN MUST COMPLY WITH THE SAFETY
REGULATIONS OF CHAPTER 10 OF CITY MUNICIPAL CODE. THE DEVELOPER SHALL OBTAIN A FLOODPLAIN
USE PERMIT FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE PERMIT FEES
PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES, GRADING, FILL,
DETENTION PONDS, BIKE PATHS, PARKING LOTS, UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL
CHANNELS, ETC.) WITHIN THE CITY OF FORT COLLINS FLOODPLAIN LIMITS AS DELINEATED ON THE FINAL
SUBDIVISION PLAT
8.ANY CONSTRUCTION ACTIVITIES, NONSTRUCTURAL DEVELOPMENT (BRIDGES, SIDEWALKS, CULVERTS,
VEGETATION, CURBCUTS, GRADING, ETC.) IN THE REGULATORY FLOODWAY MUST BE PRECEDED BY A
NORISE CERTIFICATION, WHICH MUST BE PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN THE
STATE OF COLORADO.
9.NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE FLOODWAY, WHETHER
TEMPORARY (DURING CONSTRUCTION) OR PERMANENT.
8.ANY PEDESTRIAN BRIDGES IN THE FLOODWAY THAT ARE NOT ABLE TO PASS THE 100 YEAR FLOW ARE
REQUIRED TO BE “BREAKAWAY” AND TETHERED.
9.CURVES AND LINES ARE MEASURED AT FLOWLINE, CENTERLINE OR EDGE OF WALK.
10.ATTACHED WALK WIDTHS ARE FROM FLOWLINES.
11.SINGLE POINT CURB TRANSITIONS ARE 6'.
12.SIGN PLACEMENT SHALL BE PER THE LATEST EDITION OF MUTCD REGARDLESS OF PLAN LOCATION.
13.ALL CURB & GUTTER CALLS ARE UNLESS OTHERWISE NOTED.
PROPOSED VERTICAL CURB & GUTTER
PROPERTY BOUNDARY
EXISTING LOT LINE
PROPOSED LOT LINE
ASPHALT PAVING
PROPOSED OUTFALL VERTICAL CURB & GUTTER
LEGEND:
PRIVATE CONCRETE FLATWORK
SITE SIGN LEGEND
SIGNAGE NOTE:
SIGN LOCATIONS SHOWN ARE
APPROXIMATE. FINAL LOCATION
MAY VARY.
RESERVED
PARKING
2
P
D
C
2
3
4
5
6
7
18" VERTICAL INFLOW CURB & GUTTER
18" FLUSH CURB
30" OUTFALL DRIVE-OVER CURB & GUTTER
18" VERTICAL OUTFALL CURB & GUTTER
PARALLEL ACCESS RAMP
DIRECTIONAL ACCESS RAMP
COMBINATION ACCESS RAMP
8
X' CONCRETE PAN
8
PUBLIC CONCRETE FLATWORK
HEAVY DUTY PRIVATE CONCRETE PAVING
P
FIRE LANE
1' SIDEWALK CHASE
2' SIDEWALK CHASE
X
2' CONCRETE TRICKLE PAN
1
2' CURB CUT
1
C 402 C 403
C 401C 400
SEE SHEET C 400
SEE SHEET C 403
XUDUDUDUDUDUDUDUDUDUDUDXXXXXXXXXXXXXXXXWINNE GRANT R/JOHNELLE S
1821 WALLENBERG DR
ERIKSEN CHRISTOPHER M
1825 WALLENBERG DR
MCCOY JOHN H/SHERRY P
1900 S SHIELDS ST
10' SI
D
E
W
A
L
K
10' SIDEWALK
11' SIDEWALK
TRACT BBBBBBBBBBBBB BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB8'
8.5'
8.5'
8.5'
17'
8.5'
17'
8.5'
17'
17'
26'
FL-FL
8'15'
8'
17'
50' PUBLIC ACCESS &
TRAIL EASEMENT
12' ACCESS
EASEMENT
24' ACCESS
EASEMENT
R25'
R3'
R15'
R25'R25'
R25'
R25'
R75'
SPRING CREEK
EXISTI
N
G
S
P
R
I
N
G
C
R
E
E
K
T
R
A
I
L
FEMA 100-YR HIGH
RISK FLOOD FRINGE
PROPOSED LANDSCAPE
WALL (RE: LANDSCAPE)
FEMA 100-YR
FLOODWAY
NATURAL AREA
BUFFER
PROPOSED MAINTENANCE
ACCESS PATH
D
D
D
D
D
C
PROPOSED
OVERFLOW
WEIR
2
2
2 2
2
2
1
1
1
3
7
8
6
44
6
6
4
2
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 43
NORTH
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
( IN FEET )
0
1 INCH = 30 FEET
30 30 60 90
C 403PAVING PLAN9
EASEMENTS
NOTES:
1.SEE DETAIL SHEETS FOR ADDITIONAL INFORMATION REGARDING CURBS AND PAVEMENT SECTIONS.
2.PAVEMENT MARKINGS SHALL BE PER CITY OF FORT COLLINS STANDARDS AND PROJECT SPECIFICATION
MANUAL.
3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE
CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF
FORT COLLINS STREET REPAIR STANDARDS.
4.ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS,
SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS
PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE
DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO
THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY.
5.ALL PUBLIC CONCRETE PAVING SHALL BE 6" THICK.
6.REFER TO SITE AND LANDSCAPE PLANS (BY OTHERS) FOR ADDITIONAL INFORMATION RELATED TO
DECORATIVE PAVING, HARDSCAPES, AND OTHER SITE AMENITIES.
7.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE CITYREGULATED, 100YEAR CANAL IMPORTATION
FLOODPLAIN/FLOODWAY AS WELL AS THE FEMA REGULATED SPRING CREEK 100YEAR
FLOODPLAIN/FLOODWAY. ANY DEVELOPMENT WITHIN THE FLOODPLAIN MUST COMPLY WITH THE SAFETY
REGULATIONS OF CHAPTER 10 OF CITY MUNICIPAL CODE. THE DEVELOPER SHALL OBTAIN A FLOODPLAIN
USE PERMIT FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE PERMIT FEES
PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES, GRADING, FILL,
DETENTION PONDS, BIKE PATHS, PARKING LOTS, UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL
CHANNELS, ETC.) WITHIN THE CITY OF FORT COLLINS FLOODPLAIN LIMITS AS DELINEATED ON THE FINAL
SUBDIVISION PLAT
8.ANY CONSTRUCTION ACTIVITIES, NONSTRUCTURAL DEVELOPMENT (BRIDGES, SIDEWALKS, CULVERTS,
VEGETATION, CURBCUTS, GRADING, ETC.) IN THE REGULATORY FLOODWAY MUST BE PRECEDED BY A
NORISE CERTIFICATION, WHICH MUST BE PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN THE
STATE OF COLORADO.
9.NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE FLOODWAY, WHETHER
TEMPORARY (DURING CONSTRUCTION) OR PERMANENT.
8.ANY PEDESTRIAN BRIDGES IN THE FLOODWAY THAT ARE NOT ABLE TO PASS THE 100 YEAR FLOW ARE
REQUIRED TO BE “BREAKAWAY” AND TETHERED.
9.CURVES AND LINES ARE MEASURED AT FLOWLINE, CENTERLINE OR EDGE OF WALK.
10.ATTACHED WALK WIDTHS ARE FROM FLOWLINES.
11.SINGLE POINT CURB TRANSITIONS ARE 6'.
12.SIGN PLACEMENT SHALL BE PER THE LATEST EDITION OF MUTCD REGARDLESS OF PLAN LOCATION.
13.ALL CURB & GUTTER CALLS ARE UNLESS OTHERWISE NOTED.
PROPOSED VERTICAL CURB & GUTTER
PROPERTY BOUNDARY
EXISTING LOT LINE
PROPOSED LOT LINE
ASPHALT PAVING
PROPOSED OUTFALL VERTICAL CURB & GUTTER
LEGEND:
PRIVATE CONCRETE FLATWORK
SITE SIGN LEGEND
SIGNAGE NOTE:
SIGN LOCATIONS SHOWN ARE
APPROXIMATE. FINAL LOCATION
MAY VARY.
RESERVED
PARKING
2
P
D
C
2
3
4
5
6
7
18" VERTICAL INFLOW CURB & GUTTER
18" FLUSH CURB
30" OUTFALL DRIVE-OVER CURB & GUTTER
18" VERTICAL OUTFALL CURB & GUTTER
PARALLEL ACCESS RAMP
DIRECTIONAL ACCESS RAMP
COMBINATION ACCESS RAMP
8
X' CONCRETE PAN
8
PUBLIC CONCRETE FLATWORK
HEAVY DUTY PRIVATE CONCRETE PAVING
P
FIRE LANE
1' SIDEWALK CHASE
2' SIDEWALK CHASE
X
2' CONCRETE TRICKLE PAN
1
2' CURB CUT
1
C 402 C 403
C 401C 400
SEE SHEET C 401
SEE SHEET C 402
TTTTTTTTT/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /FDC
FDC
FDC
EXISTING STRIPING (TYP.)
14' RIGHT TURN LANE
7' BIKE LANE
3' BIKE LANE BUFFER
11' LEFT/THRU LANE
11' EASTBOUND THRU LANE
3' BIKE LANE BUFFER
7' BIKE LANE
WEST STUART STREET SHIELDS STREET100' STORAGE LENGTH180' BAY TAPEREXISTING 7' SIDEWALKFUTURE PEDESTRIAN
RAMPS (FOR
REFERENCE ONLY)
FUTURE PEDESTRIAN
RAMPS (FOR
REFERENCE ONLY)
PROPOSED
PEDESTRIAN RAMPS
9' SIDEWALK
10' SIDEWALK
EXISTING ±6' BIKE LANE
EXISTING ±12'RIGHT TURN LANE
±10' LEFT/THRU LANE
EXISTING ±12' THRU LANE
EXISTING ±8' PARKING
EXISTING ±3' BIKE LANE BUFFER
PROPOSED
PEDESTRIAN RAMPS
EXISTING ±7' BIKE LANE
EXISTING ±7' BIKE LANEEXISTING ±3' BIKE LANE BUFFEREXISTING ±10' THRU LANEEXISTING ±10' THRU LANEEXISTING ±9' BIKE LANEEXISTING ±10' TURN LANEEXISTING ±10' THRU LANEEXISTING ±10' THRU LANEEXISTING ±7' BIKE LANEEXISTING ±3' BIKE LANE BUFFEREXISTING ±10' THRU LANEEXISTING ±10' THRU LANEEXISTING ±7' BIKE LANEPROPOSED ±10' TURN LANEEXISTING ±10' THRU LANEEXISTING ±10' THRU LANEEXISTING ±3' BIKE LANE BUFFERPROPOSED
STRIPING
EXISTING
STRIPING (TYP.)
PROPOSED
PAVEMENT MARKINGS
EXISTING VERTICAL
CURB & GUTTER (TYP.)EXISTING ±7' SIDEWALKEXISTING ±7' SIDEWALKEXISTING ±8' SIDEWALKPROPOSED VERTICAL
CURB & GUTTER
PROPOSED
STRIPING
PROPOSED
PAVEMENT MARKINGS
APPROXIMATE EXISTING
STRIPING (TYP.)
PROPOSED RESTRIPING OF
EXISTING LEFT TURN LANE
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 43
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
C 410INTERSECTION STRIPING PLAN10
NORTH
( IN FEET )
1 inch = ft.
Feet02020
20
40 60
EXISTING RIGHT-OF-WAY
LEGEND:
PROPOSED STORM SEWER
EXISTING STORM SEWER
PROPOSED EDGE OF ASPHALT
PROPOSED STORM MANHOLE
/ / / / / / / /
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PEDESTRIAN ACCESS RAMPS
PROPOSED CONCRETE
CROSSPAN (TYP.)
PROPOSED RIGHT-OF-WAY
NOTES:
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND
RECOMMENDATIONS.
3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN
THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS
TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS.
4.SEE INTERSECTION DETAIL SHEETS FOR INTERSECTION DESIGNS.
5.EXISTING AND PROPOSED MANHOLE RIMS AND VALVE BOX LIDS TO BE ADJUSTED TO
1
4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO
PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
PROPERTY BOUNDARY
PROPOSED LOT LINE
EASEMENT LINE
SAWCUT LINE
EXISTING LOT LINE
PROPOSED STORM INLET
C 410
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
T
MH
U
D
S
S
UDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDD
D
MH
MM
MH
/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /XXXXXXXXXXXXXXXXXSTSTSTSTSTSTSTSTWINNE GRANT R/JOHNELLE S
1821 WALLENBERG DR
ERIKSEN CHRISTOPHER M
1825 WALLENBERG DR
MCCOY JOHN H/SHERRY P
1900 S SHIELDS ST
HILL POND CONDOMINIUMS BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBXXXBBBBBBBBBXXXXXXXUDUDUDUD
UD
FDC
FDC FDCFDCFDC FDC
FDC
FDCS SHIELDS ST.HOBBIT ST.WALLENBERG DR.FEMA 100-YR
HIGH RISK
FLOOD FRINGE
CITY OF FORT COLLINS
100-YR FLOODPLAIN
PROPOSED 4'
CONCRETE PAN
PROPOSED 4'
CONCRETE PAN
PROPOSED 4'
CONCRETE PAN
PROPOSED 4'
CONCRETE PAN
PROPOSED 4'
CONCRETE PAN
PROPOSED 4'
CONCRETE PAN
PROPOSED 6'
CONCRETE PAN
PROPOSED 4'
CONCRETE PAN
PROPOSED 4'
CONCRETE PAN
PROPOSED 4'
CONCRETE PAN
PROPOSED 4'
CONCRETE PAN
EXIST
I
N
G
S
P
R
I
N
G
C
R
E
E
K
T
R
A
I
L
PROPOSED 2'
CONCRETE PAN
PROPOSED 2'
CONCRETE PAN
PROPOSED
RAIN GARDEN
PROPOSED OUTLET
STRUCTURE
PROPOSED DRAINAGE
EASEMENT
LOT 1
TRACT B
TRACT A
TRACT C
SPRI
N
G
C
R
E
E
K
RAIN GARDEN
BIOMEDIA AREA
PROPOSED 2'
CONCRETE PAN
PROPOSED 4'
SIDEWALK
CULVERTEXISTING SIDEWALKEXISTING 8' TRAILPROPOSED
LANDSCAPE WALL
CANAL IMPORTATIONPROPOSED 2'
CONCRETE PAN
STORM DRAIN 1
SEE SHEET C 620
FEMA 100-YR
FLOODWAY
CITY OF FORT
COLLINS 100-YR
FLOODWAY
W STUART ST.
STORM DRAIN 1
SEE SHEET C 620
STORM DRAIN 4-4
SEE SHEET C 624
STORM DRAIN 4-4A
SEE SHEET C 624
STORM DRAIN 4
SEE SHEET C 624
STORM DRAIN 1-9
SEE SHEET C 622
STORM DRAIN 1-8
SEE SHEET C 622
STORM DRAIN 5
SEE SHEET C 625
STORM DRAIN 5
SEE SHEET C 625
STORM DRAIN 5-2
SEE SHEET C 625
STORM DRAIN 1
SEE SHEET C 620
STORM DRAIN 2
SEE SHEET C 623
STORM DRAIN 3
SEE SHEET C 623
STORM DRAIN 6
SEE SHEET C 626
UNDERDRAIN
SEE SHEET C 626
POND
OVERFLOW PATH
POND
OVERFLOW PATH
PROPOSED
STORM CHAMBERS
PROPOSED
STORM CHAMBERS
STORM DRAIN 1-5
SEE SHEET C 621
STORM DRAIN 1-6
SEE SHEET C 621
BLDG 6
BLDG 7
BLDG 2
BLDG 3
BLDG 4
BLDG 5
BLDG 8BLDG 18BLDG 17BLDG 16BLDG 15BLDG 14
BLDG 13
BLDG 12
BLDG 11
BLDG 10
BLDG 9
BLDG 1
EMERGENCY
OVERFLOW WEIR
PROPOSED
LANDSCAPE WALL
CULVERTS
SEE SHEET U1-U4
CULVERT
SEE SHEET U1-U4
CULVERTS
SEE SHEET U1-U4
CULVERT
SEE SHEET U1-U4
AREA DRAINS
SEE SHEET U1-U4
PROPOSED OUTLET
STRUCTURE
AREA DRAINS
SEE SHEET U1-U4
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 43
C 500OVERALL GRADING PLAN11
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
NORTH
( IN FEET )
1 inch = ft.
Feet05050
50
100 150
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
PROPOSED SLOPES
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL
UNKNOWN UNDERGROUND UTILITIES.
2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD 88. SEE COVER SHEET FOR
BENCHMARK REFERENCES.
4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE
FINISHED GRADE ELEVATIONS.
5.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE CITY REGULATED 100-YR
CANAL IMPORTATION FLOODPLAIN/FLOODWAY AS WELL AS THE FEMA REGULATED
SPRING CREEK 100-YR FLOODPLAIN/FLOODWAY. ANY DEVELOPMENT WITHIN THE
FLOODPLAIN MUST COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF
CITY MUNICIPAL CODE. THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT
FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE
PERMIT FEES PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF
STRUCTURES, GRADING, FILL, DETENTION PONDS, BIKE PATHS, PARKING LOTS,
UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE
CITY OF FORT COLLINS FLOODPLAIN LIMITS ARE DELINEATED ON THE FINAL
SUBDIVISION PLAT.
6.ANY CONSTRUCTION ACTIVITIES, NONSTRUCTURAL DEVELOPMENT (BRIDGES,
SIDEWALKS, CULVERTS, VEGETATION, CURB CUTS, GRADING, ETC.) IN THE
REGULATORY FLOODWAY MUST BE PRECEDED BY A NO RISE CERTIFICATION,
WHICH MUST BE PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN THE
STATE OF COLORADO.
7.NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE
FLOODWAY, WHETHER TEMPORARY (DURING CONSTRUCTION) OR PERMANENT.
8.ANY PEDESTRIAN BRIDGES IN THE FLOODWAY THAT AR NOT ABLE TO PASS THE
100-YR FLOW ARE REQUIRED TO BE "BREAKAWAY" AND TETHERED.
NOTES:
PROPOSED STORM INLET
2.0%
(47.45
)
EXISTING SPOT ELEVATION
EXISTING LOT LINE
PROPOSED CONCRETE
CROSS PAN (TYP.)
33.43
EXISTING RIGHT OF WAY
PROPOSED LOT LINE
PROPOSED RIGHT OF WAY
LEGEND:
PROPOSED GRADE BREAK
C 501 C 502
C 503 C 504
C 506 C 505C 505
/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /6' SIDEWALK
5' SIDEWALK
6' SIDEWALK
6' SIDEWALK6' SIDEWALK
6' SIDEWALK
4.5' SIDEWALK
S SHIELDS ST.HOBBIT ST.
4.5' SIDEWALK
5' SIDEWALKFDC
FDC FDCFDC17.7617.8417.59
17.5417.2917.5417.4517.32
1
7
.
0
2
16.91
1
8
.
6
4
17.9018.34
1
8
.
3
4
16.67
16.
5
2
16.0816.
2
0
17.40 15.2816.49
16.0516.07 15.821
8
.
0
517.6016.5117.7715.17
17.
3
9
19.00 18.3418.9919.
5
8
19.65
19.65
19.
6
5
2.3%2.8%4.2%3.9%3.0%2.0%2.3%2.0%
2.1%
2.0%2.4%2.4%2.4%0.5%0.2%2.0%2.0%2.0%
0.5%0.5%
LOT 1EXISTING SIDEWALK9' SIDEWALKLOT 1
LOT 1
1.3%1.7%2.0%0.5%0.5%1.5%17.8117.8117.631.6%0.5%9' SIDEWALK1.6%0.5%29' HALF ROW
FFE=16.50
FFE=19.00
FFE=19.65 FFE=17.50
FFE=17.49
PROPOSED 4'
CONCRETE PAN PROPOSED 4'
CONCRETE PAN
PROPOSED 4'
CONCRETE PANPROPOSED 4'
CONCRETE PAN
PROPOSED 2'
CONCRETE PAN
PROPOSED 2'
CONCRETE PAN
PROPOSED
AREA DRAIN
26' EMERGENCY ACCESS EASEMENT
26' EMERGENCY ACCESS EASEMENT
26' EMERGENCY ACCESS EASEMENT
26' EMERGENCY ACCESS EASEMENT
26' EMERGENCY ACCESS EASEMENT
48' SANITARY SEWER EASEMENT
PROPOSED 30" VERTICAL
CURB & GUTTER
PROPOSED
LANDSCAPE WALL PROPOSED
AREA DRAIN
PROPOSED
AREA DRAIN
STORM DRAIN 1
SEE SHEET C 620
STORM DRAIN 1-9
SEE SHEET C 622
17.
3
1
16.3216.
7
3
16.85 2.0%2.0%PROPOSED
AREA DRAIN
PROPOSED
AREA DRAIN2.8%BUILDING 6
BUILDING 7
BUILDING 2
BUILDING 3
BUILDING 416.0216.6615.
6
2 15.5816.24 16.37
15.
1
7
15.5316.0415.911
6
.
4
8
16.42 15.4115.
9
00.5%0.5%15.6316.
0
8
2.0%
2.0%
1.7%0.5%0.7%
1
7
.
8
4
15.
2
6
15.4115.5615.
7
3
15.
9
4 15.96
15.
4
2
15.05
14.88
15.9616.0316.0817.0717.07
17.
1
8
17.05
16.52
16.54
16.61
16.49
16.40
16.1815.80
1
5
.
3
0
15.
1
1
15.7015.6115.6315.70
16.23
16.
0
9
16.
1
9
16.2217.04
1
7
.
0
017.0417.1717.
1
0
16.9316.8416.8216.61
16.
5
416.1616.29
16.2815.5315.45
17.7817.7217.700.7%17.2117.35
17.19
1
7
.
3
2
17.12
17.43
17.28
17.2616.
8
2
16.8216.9017.1315.
1
817.0616.920.5%15.1715.0215.78
15.
6
8
15.70
16.3016.20
16.17
16.19
16.2817.76
17.6017.61
17.80
18.
3
2
15.70
16.170.5%6.2%15.100.5%PROPOSED 2'
SIDEWALK
CHASES
PROPOSED 2'
SIDEWALK CHASE
PROPOSED 2'
SIDEWALK
CHASE
PROPOSED 1'
SIDEWALK CHASE
PROPOSED 2'
SIDEWALK CHASE
PROPOSED 2'
SIDEWALK CHASE
PROPOSED 1' SIDEWALK
CHASEPROPOSED 1'
SIDEWALK CHASE
PROPOSED 2'
CURB CUT
PROPOSED 2'
CURB CUT
AREA DRAINS
SEE SHEET U1-U418.4618.41
18.
3
7
18.2918.4918.2218.2519.2019.5619.0019.
0
0
19.6518.991
8
.
9
2 18.901
8
.
3
4 18.8618.2518.3418.3318.8119.6519.5619.6518.9918.9918.89
18.9019.6519.
5
0 19.6518.9918.9918.9219.5619.6518.9919.6519.
5
6
1
9
.
4
0
17.
9
0
17.8017.30
16.98
16.
9
3
16.6916.66
17.1717.6017.5418.03
18.3417.4918.0017.6217.4916.6718.7618.6817.9718.0517.
2
2
19.
6
5
19.
6
2
1
9
.
4
9
18.3217.6017.
6
3
18.
1
8 18.1017.
3
0 17.2417.0216.9519.76(19.82)19.48
19.6519.5619.39 18.5618.5918.511
8
.
0
0
17.
9
718.1219.111
9
.
1
8
19.
4
619.2419.6519.55
1
9
.
6
2
19.65
19.56 19.5619.5018.2318.27
18.49
19.4520.2819.4219.56
1
9
.
6
5
18.
9
9 18.9918.991.5%2.0%18.2918.201
8
.
2
4
4.5%3.1%2.0%2.0%2.0%2.0%18.16
0.5%18.8918.4320.25MATCH EXISTING
PAVEMENT
PROPOSED
STAIRS
PROPOSED
STAIRS
PROPOSED
STAIRS
PROPOSED 2'
SIDEWALK CHASE
2.0%1.5%1.5%1.7%2.7%1.5%PROPOSED
STAIRS
PROPOSED
STAIRS
PROPOSED
STAIRS
1.6%0.6%1.0%1.8%1.5%0.5%
0.5%
1.3%2.0%1.5%1.3%1.5%1.5%2.0%0.6%0.6%17.5016.8716.8316.7516.751
6
.
7
5
1
6
.
2
8 16.2616.7516.6116.1416.1616.6716.1715.9216.3316.2416.2515.900.5%17.0715.8016.4316.3716.06
16.49
17.4117.40
17.5016.
8
3
15.37 15.7015.6515.67
17.42 17.4617.50
1
7
.
5
0
17.
3
3
15.5815.4215.3715.
0
3
15.08
14.
7
1
14.6514.981
5
.
0
3
14.99 15.53
15.59
17.34
17.4017.5017.5017.4617.40
15.65
15.59
14.76
14.
3
914.7317.
5
0
17.4017.5016.8316.7516.7517.4016.
8
317.5017.4017.5016.8316.8315.
3
3
17.
4
0
18.87
18.92AREA DRAINS
SEE SHEET U1-U4
AREA DRAINS
SEE SHEET U1-U4
CULVERTS
SEE SHEET U1-U4
CULVERTS
SEE SHEET U1-U4
CULVERTS
SEE SHEET U1-U4
CULVERTS
SEE SHEET U1-U4
PROPOSED 2'
CONCRETE PAN
PROPOSED 2'
CONCRETE PAN
PROPOSED 2'
CONCRETE PAN
(19.64)(19.62)(20
.
2
3
)
PROPOSED 2'
PAN w/ 6" CURB
17.27
16.41
16.
3
8
1
6
.
0
1
1
5
.
9
3 15.491
5
.
2
3 14.9416.08
14.9814.871
4
.
8
2
1
5
.
2
2 15.1317.101
7
.
1
0
16.39
16.4016.7716.90
17.4017.47
17.
6
8
18.05
18.02 17.03
16.15
16.41
15.0915.
0
6
14.97
14.94
15.1315.3016.
0
5
15.24
15.2815.6416.
0
916.2016.0717.11
17.9616.821
6
.
0
6 16.0315.6115.5915.1518.3417.9817.90
17.8118.121
8
.
1
6 17.9017.6217.731
7
.
2
0
17.11
1
7
.
1
2
17.03
17.1916.671
9
.
0
0
1
8
.
9
1
1
8
.
3
4
1
8
.
3
4
18.13
1
8
.
1
3
1
7
.
4
9
16.551
7
.
7
6 18.18(19.55)(19.54)
(19
.
3
0
)
(19
.
2
9
)
(19
.
2
5
)
(19.24)
(18.90)
(18.86)
(18
.
7
9
)
(18.77)
(18.46)
(18.45)
19.00
18.94
16.
6
9
18.3316.971
9
.
0
0
18.92
18.80
18.35
18.37
18.97
18.91
19.00
18.77
17.14
17.24
18.91
19.00
18.44
18.
3
6 18.91
18.97
19.00
18.86
1
7
.
4
1 18.34
18.
3
417.6918.95
19.00
18.81
1
8
.
1
7
1
8
.
3
4
19.
0
0
18.911
9
.
0
0
18.3418.14
17.
6
417.6817.7717.7318.1518.3317.69
19.00
18.91
19.00
18.34
18.10
1
8
.
1
5 17.5618.00
17.
9
0
18.34
2.0%
1.5%
1.1%1.5%3.3%2.0%0.6%15.201
5
.
5
0
2.0%0.6%0.6%4.5%0.5%0.5%1.7%2.0%1.4%15.46
0.8%2.0%1.5%15.83
2.0%1.2%2.0%
16.
4
5
16.32
17.30
17.
4
9
17.39
16.20
16.32
16.8216.7316.7016.7516.29
16.87
16.
3
3
16.1916.2416.32
16.2516.2516.35 16.32
16.82
16.
7
5
1
6
.
6
5
16.63
16.7516.4716.26
16.82
17.49
15.92
15.7315.34
15.
8
9
16.95
16.00
16.06
15.
9
3
15.
0
9
14.
9
7
15.
1
2
15.
8
315.8315.33
15.
3
3
15.
8
4
16.
5
015.2116.
5
0
15.
3
3
15.
8
3
15.
3
3
16.50
15.
5
7 16.5015.
9
3
16.
0
0
16.5015.8315.81
15.87
15.
9
5
15.24
15.76
16.5016.41
15.91
15.55 15.4615.8515.5415.6315.9216.6116.501
6
.
8
6
1.6%2.2%2.0%
1.5%
1.5%
PROPOSED 2'
CONCRETE PAN
PROPOSED 2'
CONCRETE PAN
PROPOSED
AREA DRAIN
PROPOSED
AREA DRAIN
PROPOSED
AREA DRAIN
PROPOSED
AREA DRAIN
PROPOSED
AREA DRAIN
PROPOSED
AREA DRAIN
18.75
18.85
CULVERTS
SEE SHEET U1-U4
18.07
17.53
1.1%4.2%2.0%17.4317.010.5%0.5%0.5%
0.5%0.5%0.5%0.5%1.5%3.7%
17.49
17.39
17.49 16.8216.9516.
3
3
3.
0%1.9%3.7%0.7%
PROPOSED 2'
CONCRETE PAN
PROPOSED 2'
CONCRETE PAN
16.
4
0
16.
0
3
17.
4
0
15.60
PROPOSED 1'
SIDEWALK CHASE
15.76
15.91
16.4115.7515.7815.83
15.
6
9
16.
4
115.8215.8316.13PROPOSED 2'
CURB CUT 2.0%2.0%2.3%1.8%2.2%2.3%1.3%1.0%
15.18
1.5%PROPOSED
AREA DRAIN
PROPOSED
AREA DRAINPROPOSED
AREA DRAIN
15.
7
1
PROPOSED
STAIR
16.50
PROPOSED
STAIR
PROPOSED
STAIR
16.50
2.0%1.8%1.6%1.8%1.8%2.0%2.0%2.0%2.9%2.0%0.5%2.6%1.7%2.7%2.0%0.5%
17.40
1
6
.
1
4
1
6
.
1
61.5%18.22
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 43
C 501GRADING PLAN12
( IN FEET )
0
1 INCH = 20 FEET
20 20 40 60
NORTH
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
PROPOSED SLOPES
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL
UNKNOWN UNDERGROUND UTILITIES.
2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD 88. SEE COVER SHEET FOR
BENCHMARK REFERENCES.
4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE
FINISHED GRADE ELEVATIONS.
5.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE CITY REGULATED 100-YR
CANAL IMPORTATION FLOODPLAIN/FLOODWAY AS WELL AS THE FEMA REGULATED
SPRING CREEK 100-YR FLOODPLAIN/FLOODWAY. ANY DEVELOPMENT WITHIN THE
FLOODPLAIN MUST COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF
CITY MUNICIPAL CODE. THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT
FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE
PERMIT FEES PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF
STRUCTURES, GRADING, FILL, DETENTION PONDS, BIKE PATHS, PARKING LOTS,
UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE
CITY OF FORT COLLINS FLOODPLAIN LIMITS ARE DELINEATED ON THE FINAL
SUBDIVISION PLAT.
6.ANY CONSTRUCTION ACTIVITIES, NONSTRUCTURAL DEVELOPMENT (BRIDGES,
SIDEWALKS, CULVERTS, VEGETATION, CURB CUTS, GRADING, ETC.) IN THE
REGULATORY FLOODWAY MUST BE PRECEDED BY A NO RISE CERTIFICATION,
WHICH MUST BE PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN THE
STATE OF COLORADO.
7.NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE
FLOODWAY, WHETHER TEMPORARY (DURING CONSTRUCTION) OR PERMANENT.
8.ANY PEDESTRIAN BRIDGES IN THE FLOODWAY THAT AR NOT ABLE TO PASS THE
100-YR FLOW ARE REQUIRED TO BE "BREAKAWAY" AND TETHERED.
NOTES:
PROPOSED STORM INLET
2.0%
(47.45
)
EXISTING SPOT ELEVATION
EXISTING LOT LINE
PROPOSED CONCRETE
CROSS PAN (TYP.)
33.43
EXISTING RIGHT OF WAY
PROPOSED LOT LINE
PROPOSED RIGHT OF WAY
LEGEND:
PROPOSED GRADE BREAK
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
SEE SHEET C 503 SEE SHEET C 502C 501 C 502
C 503 C 504
C 506 C 505C 505
XUDU
D
U
D
U
D
U
DUDUDUDUD
UD
UD
UD UD UD UD UD UD UD UD UD UD UD UD UD UD
UD S
S
UDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
XXXXXXXXX5' SIDEWALK
6' SIDEWALK
9' SIDEWALK9' SIDEWALK9' SIDEWALK9' SIDEWALK7' SIDEWALK7' SIDEWALK7' SIDEWALK7' SIDEWALK6' SIDEWALKUDUDUDUDUDUDUDFDCFDC FDC
FDC
13.3313.62
13.31
1
3
.
8
9 13.5415.1915.
2
6
14.71
15.
3
5
15.
0
6
15.43
15.4014.05
14.1914.39 14.23
14.3313.94
13.
9
114.1314.92
14.92
14.51
13.5414.1514.5312.
7
3
12.13
14.9115.
0
6
14.97
14.99
16.6716.1516.
4
0
15.90
14.76
14.
7
7
14.3314.33
14.28
1
4
.
1
8
4' SIDEWALK
4' SIDEWALK
5' SIDEWALK
0.7%1.5%2.9%
0.6%0.5%1.9%1.2%2.0%2.0%2.8%
2.3%
1.8%
2.0%
2.9%0.2%0.6%0.5%0.5%10' SIDEWALK4' SIDEWALKLOT 1
TRACT A
LOT 1 EXISTING 8' TRAIL(12.40)(11.88)HOBBIT ST
13.31
LOT 1
LOT 1
13.54
13.941
3
.
8
1
6' SIDEWALK
0.7%0.5%
13.90 12.913.8%2.0%
4.5%
1.5%
3.5%
FFE=16.50 FFE=16.67
FFE=15.65
FFE=15.00
FFE=15.00
FFE=14.83
FFE=14.83
FFE=15.00
FFE=15.00
FFE=15.43
FFE=15.43
FFE=15.82FFE=15.82
PROPOSED 4'
CONCRETE PAN
PROPOSED 4'
CONCRETE PAN
PROPOSED 4'
CONCRETE PAN
PROPOSED
AREA DRAIN
PROPOSED
AREA DRAIN 26' EMERGENCYACCESS EASEMENT26' EMERGENCY ACCESS EASEMENT
48' SANITARY SEWER EASEMENT
NATURAL AREA
BUFFER48' SANITARY SEWER EASEMENTPROPOSED 4'
CONCRETE PAN
STORM DRAIN 1
SEE SHEET C 620
TIE TO EXISTING
CURB & GUTTER
EXISTING
30" VERTICAL
CURB & GUTTER
STORM DRAIN 1-6
SEE SHEET C 622
PROPOSED 4'
CONCRETE PAN15.2615.38
PROPOSED 2'
SIDEWALK CHASE
13.63
10.52
2.0%
2.0%
PROPOSED
FOREBAY
1
6
.
6
0
BUILDING 18 BUILDING 17
BUILDING 16
BUILDING 15
BUILDING 14
BUILDING 13
BUILDING 12
BUILDING 11
BUILDING 10
BUILDING 9
BUILDING 4 BUILDING 5
BUILDING 812.9813.
8
3
15.
0
3 14.3216.061
5
.
7
0
1
5
.
6
22.0%2.0%2.0%2.8%
3.6%
14.44
10.409.72
9.87
13.53
14.
4
7
14.5012.2213.72
10.85
13.
7
2
10.
3
710.620.5%0.8%0.5%13.9815.2515.42
PROPOSED 2'
CONCRETE PAN
PROPOSED
AREA DRAIN
PROPOSED
AREA DRAIN
PROPOSED
AREA DRAIN
15.02
1
4
.
8
9
14.90
14.98
15.53
15.7215.0914.5614.3814.14
14.05
14.51 14.4515.3415.2115.23
15.
4
2
14.7414.66
14.6814.9114.
5
0
13.871
3
.
7
9
13.54
13.69
13.28
13.
1
7
13.62
13.60
13.65
13.75
12.
9
4
12.
8
8
13.1713.
0
2
13.03
13.22
12.9112.8513.34
13.41 13.611
3
.
5
5
13.5613.661
3
.
5
913.5214.2114.22
13.0614.11
13.95
1
4
.
5
6
13.01
14.83
11.59
STORM DRAIN 1-5
SEE SHEET C 621
STORM DRAIN 1-6
SEE SHEET C 621
PROPOSED 2'
SIDEWALK
CHASE
PROPOSED 1'
SIDEWALK CHASE
PROPOSED 1'
SIDEWALK CHASE
PROPOSED 1'
SIDEWALK CHASE
PROPOSED 2'
SIDEWALK CHASE
PROPOSED 1'
SIDEWALK CHASE
PROPOSED 1'
SIDEWALK CHASE
PROPOSED 2'
SIDEWALK CHASE
PROPOSED 2'
SIDEWALK CHASE
PROPOSED 1'
SIDEWALK CHASE
29' HALF ROW
PROPOSED
STAIRS
1.5%1.5%14.6514.9815.53
15.59
17.34
17.4017.5017.5017.4617.40
15.65
15.59
14.76
14.
3
914.7314.341
4
.
6
8
17.
5
0
17.4017.50
15.46
0.8%1.5%15.83
16.
5
0 15.921.8%PROPOSED
STAIRS
PROPOSED 2'
SIDEWALK CHASE
PROPOSED
LANDSCAPE WALL
PROPOSED 2'
CONCRETE PAN
(13.06)13.10MATCH EXISTING
PAVEMENT
AREA DRAINS
SEE SHEET U1-U4
PROPOSED 1'
SIDEWALK CHASE
PROPOSED 1'
SIDEWALK CHASE17.5016.8317.
4
0
15.5315.59 14.1315.
4
5
14.2014.0214.0214.5913.4215.2615.3815.751
6
.
8
3 15.9815.8915.7215.8215.3114.7014.46
15.101
5
.
1
6
15.0014.9014.7914.
9
1
13.
9
514.4914.3715.
0
5
15.1015.02
15.03
15.13
14.97
15.20
15.6415.7415.3216.7516.1716.75 16.8316.8315.3416.8316.8316.8316.8316.8314.2813.86MATCH EXISTING
SIDEWALK
(13.52)MATCH EXISTING
PAVEMENT
14.5214.2814.1416.0814.7315.6214.
5
6
1
4
.
0
214.1213.4112.73(12.86)12.6812.5812.2511.96 12.1812.15
12.06
12.40(12.48)(12.27)(12.22)(1
3
.
2
5
)12.9012.1012.8313.0113.0412.03 12.0512.8613.8613.9315.4315.4915.1610.7312.1411.1915.2715.4815.4615.4915.4915.4815.1515.5415.1715.0815.10
14.34 14.1614.2514.2714.701
4
.
9
6
14.1214.2614.9015.
3
6
15.
5
3
15.
1
7
14.
6
2 14.5814.0014.0113.
9
2
14.
0
5
13.
7
3
13.44
13.
4
5
13.
4
8
13.
7
1
12.
4
2
12.
3
4
12.
0
9
14.
8
9
14.
7
8
15.
1
0
15.
1
0
15.
1
0
15.
1
0
15.
0
7
15.
1
0
15.
1
0
14.
8
9
15.
1
0
15.
1
0
13.
9
4
14.
0
9
12.
6
9
12.
4
7
14.
7
7
15.
2
8
15.
4
9
15.
4
9
15.
4
9
15.
4
9
15.
1
6
14.
3
9
14.
8
114.9313.
7
7
13.85
14.3814.
6
3
15.
0
0 15.3615.4415.4915.
1
6
14.
4
4
14.
5
4
14.
3
9
14.
5
5
14.
6
4
13.
7
4
13.
7
4
13.
1
9
14.
2
6
14.09 14.01
13.74
13.14
14.41 13.88
13.79 13.77
13.86 14.32
14.5714.44
14.49 14.41
14.0413.61
14.15
14.10
14.
2
7
14.3213.64
13.7213.86
13.94
13.80
14.71
14.62
1
4
.
5
7
14.
6
6
15.1015.06
14.92
15.55
15.65
14.4114.9815.44
14.
7
1
14.8514.03
14.
7
0
15.3815.77
15.86
15.84
15.70
15.30
16.6716.02
15.8415.84
16.03
16.
5
714.9715.9315.3515.3515.2615.8416.5016.1416.161
6
.
5
0
1
6
.
0
5
1
5
.
3
3
14.8915.361
6
.
2
1
1
6
.
5
7
16.6715.8416.001
6
.
0
9
1
6
.
6
716.311
6
.
2
1
1
6
.
6
716.561
6
.
0
516.4116.5016.0516.1516.501
5
.
8
3 16.0016.5016.4116.051
6
.
0
5
1
6
.
1
5
1
6
.
5
0
15.831
3
.
9
215.1214.181
6
.
2
1
16.6716.5716.211
6
.
6
7
1
6
.
3
1
1
6
.
0
0
16.00
15.3815.4315.3816.0116.0116.1716.67
16.671
6
.
5
7
16.01
16.07
16.57
14.6314.07 14.9215.55
1
5
.
6
5
1
5
.
6
5
1
5
.
5
515.5515.6515.551
4
.
3
114.0514.67
14.62
12.
8
7
14.
6
7
14.62
12.
8
7
11.
2
2
13.7212.501
0
.
7
1
14.33
14.33 12.76
9.9211.0110.29
10.18
9.95
10.91
1
0
.
8
810.6816.01
16.
0
0
16.00
16.00
1
6
.
6
7
16.67 16.1716.01
16.01
16.62
16.07
1
6
.
5
716.671
6
.
0
016.0016.00
16.01
15.38
15.48
14.88 14.32
15.94
16.00
15.55
15.55
15.55
15.65
14.
0
2
14.03
1
4
.
0
3
15.55
15.6515.55
15.55
1
5
.
5
5
15.1513.5614.98
15.00
14.34
15.6515.5515.39
14.98
14.71
14.72
15.65
15.5515.31
15.18
15.31
15.65
15.00
14.68
14.69
14.08
15.3115.
6
5
15.5515.31
15.65 15.18 14.04
14.
2
5
14.40
15.
0
0
14.89
14.89
14.74
13.53
13.
5
4
14.51
15.40
15.
5
515.6513.00
14.50
14.30
14.50
14.48
14.50
14.50
14.50
14.50
14.30
14.5013.3012.52
13.36
13.8113.75
14.34 14.17
PROPOSED
RAIN GARDEN
UNDERDRAIN 1
SEE SHEET C 626
14.
6
7
14.
6
7
14.
6
7
14.
6
7
14.
6
4
14.
6
7
14.
6
7
14.
4
7
14.
6
7
14.
6
7
12.70
12.71
12.72
12.73
14.
3
3
14.
6
7
14.
3
3
14.67
14.58
14.
0
8
13.
7
6
13.70
13.
2
0
13.18
13.
4
8
13.79
14.
2
2 14.1614.
4
3
13.
8
4
12.41
8.50
8.50
8.5012.9112.1613.24
14.6714.3314.5613.74
14.
0
9
14.02
13.70
14.0714.0014.54
14.
5
314.5614.54
13.
8
3
14.32
14.67 14.6714.62
13.7913.79
13.73
14.33
14.3513.5514.06
14.0613.
5
4
13.5413.1013.6714.0914.14
14.33
14.33
14.12
14.33
14.30
14.33
14.33 14.33
14.33 14.33
14.12
14.33
8.
5
0
12.6112.79
8.50
12.79
8.50
12.79
8.5012.919.2412.79
8.26 (8.08)
9.54
9.749.979.77
11.
4
5
11.25
11.2411.44
11.4712.4712.01
12.0012.6413.2213.2815.0315.
1
0
11.6311.06
11.0111.22
10.9411.17
11.2212.4912.5112.6413.2313.2915.0215.
1
0 12.1512.129.77
10.60 10.47
10.1910.019.89
9.72
9.88
10.60
10.60
10.58 (9.62)(9.67)
12.
2
6
13.
7
3
12.
8
6
13.
5
4
14.
1
40.6%0.5%1.2%5.6%4.1%3.
2
%1.9%1.0%1.0%2.0%0.7%1.5%2.0%1.5%
1.5%
0.5%
2.1%
1.8%14.1814.
7
9
14.432.4%2.0%2.0%2.0%2.0%2.0%
3.2%2.0%
2.8%
4.0%
1.5%
2.0%1.5%
1.2%4.5%1.5%2.5%2.5%1.4%PROPOSED 2'
CONCRETE PAN
1.7%
2.0%
3.2%
1.5%
1.5%
2.0%2.0%
4.0%
2.0%
1.
6
%0.5%0.5%1.5%2.0%2.0%0.5%1.6%1.6%3.7%1.6%
10.00
10.20
10.
3
6
12.7711.779.00
0
.
5%
2.0%1.6%1.5%3.8%3.1%0.6%3.1%2.6%2.0%3.0%PROPOSED
STAIR
PROPOSED
STAIRS
PROPOSED
STAIR
PROPOSED
STAIRS
PROPOSED
STAIRS
PROPOSED
STAIRS
PROPOSED
STAIRS
PROPOSED
STAIRS
PROPOSED
STAIRS
PROPOSED
STAIRS
PROPOSED
STAIRS
PROPOSED
STAIRS
PROPOSED
STAIRS
PROPOSED
STAIRS
PROPOSED 4'
CONCRETE PAN
PROPOSED 1'
SIDEWALK CHASE
PROPOSED 2'
SIDEWALK CHASE
PROPOSED
LANDSCAPE WALL
PROPOSED
AREA DRAIN1.0%1.5%1.5%1.1%2.3%
2.7%
2.0%2.0%(10.82)PROPOSED 2'
SIDEWALK CHASE
PROPOSED 2'
SIDEWALK CHASE
PROPOSED 2'
SIDEWALK CHASE
0.5%
PROPOSED 2'
SIDEWALK CHASE 0.6%16.
5
7 13.5414.15
1
4
.
5
0 (8.13)(8.00)(11.89)
4:1
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 43
C 502GRADING PLAN13
( IN FEET )
0
1 INCH = 20 FEET
20 20 40 60
NORTH
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
PROPOSED SLOPES
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL
UNKNOWN UNDERGROUND UTILITIES.
2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD 88. SEE COVER SHEET FOR
BENCHMARK REFERENCES.
4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE
FINISHED GRADE ELEVATIONS.
5.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE CITY REGULATED 100-YR
CANAL IMPORTATION FLOODPLAIN/FLOODWAY AS WELL AS THE FEMA REGULATED
SPRING CREEK 100-YR FLOODPLAIN/FLOODWAY. ANY DEVELOPMENT WITHIN THE
FLOODPLAIN MUST COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF
CITY MUNICIPAL CODE. THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT
FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE
PERMIT FEES PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF
STRUCTURES, GRADING, FILL, DETENTION PONDS, BIKE PATHS, PARKING LOTS,
UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE
CITY OF FORT COLLINS FLOODPLAIN LIMITS ARE DELINEATED ON THE FINAL
SUBDIVISION PLAT.
6.ANY CONSTRUCTION ACTIVITIES, NONSTRUCTURAL DEVELOPMENT (BRIDGES,
SIDEWALKS, CULVERTS, VEGETATION, CURB CUTS, GRADING, ETC.) IN THE
REGULATORY FLOODWAY MUST BE PRECEDED BY A NO RISE CERTIFICATION,
WHICH MUST BE PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN THE
STATE OF COLORADO.
7.NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE
FLOODWAY, WHETHER TEMPORARY (DURING CONSTRUCTION) OR PERMANENT.
8.ANY PEDESTRIAN BRIDGES IN THE FLOODWAY THAT AR NOT ABLE TO PASS THE
100-YR FLOW ARE REQUIRED TO BE "BREAKAWAY" AND TETHERED.
NOTES:
PROPOSED STORM INLET
2.0%
(47.45
)
EXISTING SPOT ELEVATION
EXISTING LOT LINE
PROPOSED CONCRETE
CROSS PAN (TYP.)
33.43
EXISTING RIGHT OF WAY
PROPOSED LOT LINE
PROPOSED RIGHT OF WAY
LEGEND:
PROPOSED GRADE BREAK
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
SEE SHEET C 504SEE SHEET C 501SEE SHEET C 501C 501 C 502
C 503 C 504
C 506 C 505C 505PROPOSED 2' PAN
w/ 6" CURBS
D
/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /STSTSTSTSTSTSTSTSTST6' SIDEWALK6' SIDEWALK
9' SIDEWALK
6' SIDEWALK
6' SID
E
W
A
L
K
UD
UD
UD
UD
FDC
FDC
17.
2
8
17.1717.15
17.20
16.75
16.72
16.77
16.
7
8
17.11
17.10
16.32
16.66 16.1216.
0
4
16.13
16.1816.33
16.55
16.39
16.98
19.00
17.2717.58
15.5417.051.5%1.5%3.0%2.5%1.4%2.5%2.0%2.0%2.0%
0.9%S SHIELDS STTRACT C
LOT 1
SPRIN
G
C
R
E
E
K
EXIST
I
N
G
S
P
R
I
N
G
C
R
E
E
K
T
R
A
I
LEXISTING SIDEWALKEXISTING SIDEWALKTRACT B2.0%15.8517.16
5:16:19:14
:
1
7:1 6:1FFE=17.27
FFE=17.49
PROPOSED 4'
CONCRETE PAN
PROPOSED 2'
CONCRETE PAN
PROPOSED 2'
SIDEWALK CHASE
PROPOSED
AREA DRAIN
EXISTING 30"
STORM DRAIN
PROPOSED
AREA DRAIN
31' EMERGENCY
ACCESS EASEMENT
33' WATER EASEMENT
PROPOSED 4'
SIDEWALK CULVERT
PROPOSED 2'
SIDEWALK
CHASE
FEMA 100-YR
HIGH RISK
FLOOD FRINGE
PROPOSED 2'
CONCRETE PAN
PROPOSED STORM
CHAMBERS
STORM DRAIN 4-4A
SEE SHEET C 624
STORM DRAIN 4
SEE SHEET C 624
STORM DRAIN 4-4
SEE SHEET C 624
STORM DRAIN 5
SEE SHEET C 625
STORM DRAIN 4
SEE SHEET C 624
STORM DRAIN 6
SEE SHEET C 626
9' SIDEWALK 16.3016.362.0%2.0%2.0%1
6
.
7
0
BUILDING 3
POND OVERFLOW
CHANNEL
WQ ELEV. = 5012.20
100YR ELEV. = 5014.91
16.83
16.87
1
6
.
2
2
1
6
.
1
7
17.27
12.00
0.5%
17.
0
3 16.2716.23
BUILDING 1
16.14
15.99
15.83
15.65
15.
6
3
15.78 15.62
15.67
15.
7
0
15.91
15.90
16.0216.
5
0
16.46
16.49
16.
4
416.3816.
3
9
16.49
16.92
16.9416.8917.00
16.90
16.4316.46
16.23
16.8716.5116.16
16.
2
5
16.45
16.
0
0
15.84
0.5%
16.92
16.10
PROPOSED 2'
SIDEWALK CHASE
PROPOSED 2'
SIDEWALK CHASE
PROPOSED
AREA DRAIN
(18.46)
(18.45)
18.94
16.
6
9
18.80
17.
9
0
18.34
16.00
16.06
15.
9
3
15.
0
9
15.
1
2
15.
8
32.2%0.5%16.
3
3
17.
4
0 15.76
PROPOSED
AREA DRAIN
(18.41)
(18.40)
(18.32)
(18.34)(17.79)(17.08)
(17.43)(17.45)(17.90)(17.62)(18.47)
PROPOSED
LANDSCAPE WALL
PROPOSED 1'
SIDEWALK CHASE
CULVERTS
SEE SHEET U1-U4
PROPOSED 2'
CONCRETE PAN
PROPOSED 2'
CONCRETE PAN
16.
2
6
16.33
15.33
15.33
16.4116.5015.33
15.2816.6616.7416.4216.3216.54
17.
1
5
PROPOSED
STAIR
PROPOSED
STAIR
17.14
16.
7
4
16.
5
3
16.
0
0
15.
8
5
15.4315.
3
7
15.
2
6
15.
6
2
15.66
16.
2
3
16.
2
6
16.3116.3517.
1
5
17.
1
3
17.
0
6
16.
7
5
17.15
17.14
16.82
16.
1
2
16.
6
6
17.20
17.13
16.9116.
2
1
16.
2
6
16.
2
4
16.82
15.
9
8
17.40
16.78
17.
1
9
17.
2
717.
2
7
17.
2
7
17.
1
7
18.33
PROPOSED
STAIRS
17.
2
0
17.
2
1
17.
2
1
17.27 17.2017.
2
7
17.25
17.
2
7
17.
0
7
PROPOSED 2'
CONCRETE PAN
PROPOSED
FLUSH CURB
17.
2
2
17.
3
0
17.
1
9
17.
1
9
17.
2
7
17.
2
7
17.28 17.33
17.5616.94
17.28
17.26
17.27
17.27
17.27
17.75
1
7
.
5
9
17.38
17.42
16.28
16.
7
8
16.84
16.9417.57
16.98
17.27 17.2717.27
17.25
17.1316.58
17.27
17.27(17.73)17.22
17.27
17.27
17.2716.8817.19
16.2817.1417.10
18.09
18.13
16.71
18.21
18.32
17.2117.99 18.00
17.87
17.80
17.98
16.8317.76
18.22
16.24
16.51
1
7
.
0
1
15.9415.71
15.30
15.84
15.
1
8
15.09
14.
7
1
14.05
13.0015.0715.2215.4815.5315.4115.89
16.25 16.13
16.05
11.26
11.34
11.08
11.05 10.95
11.08
17.25
17.41
11.65
11.31
12.83
13.00
12.18
12.19
13.60
14.61
14.75
15.29
15.14
14.60
16.23
16.26
16.81
16.86
17.34
17.31
16.83
16.98
17.01 17.59
17.54
17.57
17.3917.27
17.25
17.39
17.33
17.
5
7
17.62
17.6017.39
17.43
17.47
17.
0
9
17.
1
4
17.52
17.52
16.89
16.88
17.28 0.5%17.550.5%1.5%2.0%0.5%0.9%1.6%1.5%2.0%2.5%2.0%
0.5%
0.5%
0.8%2.0%4.0%3.8%2.0%2.0%0.5%2.0%1.5%0.5%1.5%5.6%
0.5%
0.5%2.0%1.3%1.3%1.5
%1.3%0.5%
0.8%1.5%
1
.
5%
2.1%
1.6%2.2%
1.6
%
15.72
15.64 1.5%1.5%0.5
%1.0%2.0%0.5%0.5%0.5%3.0%0.
5
%0.5%0.5%0.5%
15.48
0.5%0.5%15.571.0%17.9917.8617.7517.72PROPOSED 2'
CONCRETE PAN
PROPOSED
LANDSCAPE
WALL
1.5%
1
8
.
3
4
2.7%1.9%(17.84)
EXISTING 30"
VERTICAL
CURB & GUTTER
EXISTING 30"
VERTICAL
CURB & GUTTER
TIE TO
EXISTING
TIE TO
EXISTING
MATCH
EXISTING
TIE TO
EXISTING
TIE TO
EXISTING 1.0%
0
.
6%
PROPOSED MAINTENANCE
ACCESS PATH 5:14:
1
7:1PROPOSED
FLUSH CURB
TIE TO
EXISTING
FEMA 100-YR
FLOODWAY
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 43
C 503GRADING PLAN14
( IN FEET )
0
1 INCH = 20 FEET
20 20 40 60
NORTH
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
PROPOSED SLOPES
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL
UNKNOWN UNDERGROUND UTILITIES.
2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD 88. SEE COVER SHEET FOR
BENCHMARK REFERENCES.
4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE
FINISHED GRADE ELEVATIONS.
5.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE CITY REGULATED 100-YR
CANAL IMPORTATION FLOODPLAIN/FLOODWAY AS WELL AS THE FEMA REGULATED
SPRING CREEK 100-YR FLOODPLAIN/FLOODWAY. ANY DEVELOPMENT WITHIN THE
FLOODPLAIN MUST COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF
CITY MUNICIPAL CODE. THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT
FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE
PERMIT FEES PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF
STRUCTURES, GRADING, FILL, DETENTION PONDS, BIKE PATHS, PARKING LOTS,
UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE
CITY OF FORT COLLINS FLOODPLAIN LIMITS ARE DELINEATED ON THE FINAL
SUBDIVISION PLAT.
6.ANY CONSTRUCTION ACTIVITIES, NONSTRUCTURAL DEVELOPMENT (BRIDGES,
SIDEWALKS, CULVERTS, VEGETATION, CURB CUTS, GRADING, ETC.) IN THE
REGULATORY FLOODWAY MUST BE PRECEDED BY A NO RISE CERTIFICATION,
WHICH MUST BE PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN THE
STATE OF COLORADO.
7.NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE
FLOODWAY, WHETHER TEMPORARY (DURING CONSTRUCTION) OR PERMANENT.
8.ANY PEDESTRIAN BRIDGES IN THE FLOODWAY THAT AR NOT ABLE TO PASS THE
100-YR FLOW ARE REQUIRED TO BE "BREAKAWAY" AND TETHERED.
NOTES:
PROPOSED STORM INLET
2.0%
(47.45
)
EXISTING SPOT ELEVATION
EXISTING LOT LINE
PROPOSED CONCRETE
CROSS PAN (TYP.)
33.43
EXISTING RIGHT OF WAY
PROPOSED LOT LINE
PROPOSED RIGHT OF WAY
LEGEND:
PROPOSED GRADE BREAK
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
SEE SHEET C 501
SEE SHEET C 504SEE SHEET C 505
C 501 C 502
C 503 C 504
C 506 C 505C 505
XXXXXMCCOY JOHN H/SHERRY P
1900 S SHIELDS STBBBBBBBBBBBBBB BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBXBBBBBB6' SIDEWALK
6' SID
E
W
A
L
K
10' SID
E
W
A
L
K
11' SIDEWALK
10' SIDEWALK
UD UD UD
UD
13.79
14.
7
2
14.72
16.
0
6
15.35
15.
7
6
16.47
16.5515.15
14.84
14.25
13.72
13.32
13.33
14.16
13.23
12.5514.5815.29
14.51
EXISTING
S
P
R
I
N
G
C
R
E
E
K
T
R
A
I
L
15.
0
6
14.97
15.
6
4
16.
4
0
8.1114.17
2.0%1.7%2.1%2.2%0.5%
1.9%
2
.
8%
0.6%
0.9%
SPRING CRE
E
K
TRACT B
LOT 1
LOT 1
0.5%15.853.2%2.0%9' SIDEWALK
2.0%10:16:14:1
6.
7
9
FFE=14.83
EXISTING FEMA
100-YR HIGH RISK
FLOOD PLAIN
PROPOSED 4'
CONCRETE PAN
PROPOSED 4'
CONCRETE PAN
PROPOSED 4'
CONCRETE PAN
PROPOSED
RAIN GARDEN
26' EMERGENCY ACCESS EASEMENT
33' WATER EASEMENT
NATURAL AREA
BUFFER
PROPOSED 4'
CONCRETE PAN
PROPOSED RETAINING
WALL (RE: LANDSCAPE)
PROPOSED 2'
CONCRETE PAN
PROPOSED STORM
CHAMBERS
STORM DRAIN 2
SEE SHEET C 623
FEMA 100-YR
FLOODWAY
PROPOSED 6'
CONCRETE PAN
NATURAL AREA
BUFFER
13.61
13.572.0%2.0%16.3016.
1
8 15.7416.362.0%2.0%2.0%BUILDING 9
100YR ELEV. = 5011.604:14:14:14:112.8612.97
12.53
1.9%1.9%14.6914.69
14.0414.3113.
8
2
12.95
12.
8
4
13.50
13.65
13.
4
3
1.9%0.5%
13.53
12.34
15.01
14.89
15.07
14.86
14.23
14.20
1
4
.
0
5
15.
9
0
15.86
15.90
16.02
16.27 16.1614.80
13.
8
8
14.04
13.33
13.23
13.28
13.22
12.79
12.57
12.
5
4
12.5913.0612.92
12.17
11.98
12.95
12.87
13.
2
9
13.74
13.80
14.59
14.82
16.
0
0
15.84
12.
5
9
12.59
12.70
14.1813.97
PROPOSED 2'
SIDEWALK CHASE
PROPOSED 2'
SIDEWALK CHASE
2.0%
16.00
15.94
16.00
13.002.0%2.8%
1.3%1.4%16.4216.321
7
.
5
9
16.51
1
7
.
0
1
15.9415.14
14.60 2.0%
0.5%1.5%
1
.
5%1.5%PROPOSED 6'
CONCRETE PAN
PROPOSED STAIRS
15.3316.0516.5014.
8
6
16.
2
1
16.
5
7
16.
6
7
15.
5
0
15.39
15.
1
8
14.
8
0
14.
3
9
14.
1
9
14.
3
1
14.
8
3
15.
4
6
15.
5
1
15.
4
6
15.
5
1
15.
7
0
15.
6
3
16.
1
9
16.
4
1
16.
4
7
16.
8
2
17.
0
7
16.
3
4 15.3814.28
14.7815.2116.57
15.38
16.67
PROPOSED
STAIRS
14.711
4
.
2
3
14.20
14.77
13.89 13.41
13.41
13.32
13.59 14.09
14.16 14.19
14.10
13.92
14.33
14.73
14.98
14.17
13.6513.6514.1113.5213.5113.57
13.4413.9513.6014.0214.0613.5414.15
13.35PROPOSED
CURB CUT 14.0013.4713.3913.4913.3713.
5
9
1
4
.
5
0
14.
4
6
13.4613.521
3
.
3
6
14.45
14.50
1
3
.
3
7
13.1713.
1
3
12.9612.4412.0012.0011.8311.8312.008.5012.8512.5012.7713.2413.14
12.9412.48
12.2813.
2
6
8.00 8.0012.13
7.
9
78.8310.1310.5812.58
12.429.979.9
7
1
2
.
4
2
10.42
8.65
10.1310.5812.5813.6212.6410.64
10.198.198.09
10.6412.5913.1410.9312.
9
3
10.48
8.488.30
8.3410.1910.488.5610.9312.
9
3
10.488.3610.7011.0012.9311.0014.
3
3 7.717.297.026.85STORM DRAIN 5
SEE SHEET C 625
14.55
14.00
14.7314.5615.51 14.9114.5813.9613.5314.4714.4214.48
15.2315.35 15.3215.
2
7
1
4
.
9
9
15.1015.2616.
1
2
15.50
16.89
15.67
16.50
15.36
13.90
16.38
13.04
14.52 14.39
13.8414.0013.1813.24
8.50
1.5%2.0%2.0%2.0%0.5%1.3%1.
6
%
0.6%0.5%1.9%0.5%2.0%2.0%2.0%0.5%
12.
6
2
12.7413.000.5%1.5%2.0%2.0%1.6%1.0%0.9%0.5%1.
2
%
1.5%
1.5%1.9%1.7%
0.9%1.8%7:10.5%
0.5
%
2.0
%2.0%
6.758.0012.1312.8013.
1
1
100YR ELEV. = 5011.37
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 43
C 504GRADING PLAN15
( IN FEET )
0
1 INCH = 20 FEET
20 20 40 60
NORTH
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
PROPOSED SLOPES
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL
UNKNOWN UNDERGROUND UTILITIES.
2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD 88. SEE COVER SHEET FOR
BENCHMARK REFERENCES.
4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE
FINISHED GRADE ELEVATIONS.
5.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE CITY REGULATED 100-YR
CANAL IMPORTATION FLOODPLAIN/FLOODWAY AS WELL AS THE FEMA REGULATED
SPRING CREEK 100-YR FLOODPLAIN/FLOODWAY. ANY DEVELOPMENT WITHIN THE
FLOODPLAIN MUST COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF
CITY MUNICIPAL CODE. THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT
FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE
PERMIT FEES PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF
STRUCTURES, GRADING, FILL, DETENTION PONDS, BIKE PATHS, PARKING LOTS,
UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE
CITY OF FORT COLLINS FLOODPLAIN LIMITS ARE DELINEATED ON THE FINAL
SUBDIVISION PLAT.
6.ANY CONSTRUCTION ACTIVITIES, NONSTRUCTURAL DEVELOPMENT (BRIDGES,
SIDEWALKS, CULVERTS, VEGETATION, CURB CUTS, GRADING, ETC.) IN THE
REGULATORY FLOODWAY MUST BE PRECEDED BY A NO RISE CERTIFICATION,
WHICH MUST BE PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN THE
STATE OF COLORADO.
7.NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE
FLOODWAY, WHETHER TEMPORARY (DURING CONSTRUCTION) OR PERMANENT.
8.ANY PEDESTRIAN BRIDGES IN THE FLOODWAY THAT AR NOT ABLE TO PASS THE
100-YR FLOW ARE REQUIRED TO BE "BREAKAWAY" AND TETHERED.
NOTES:
PROPOSED STORM INLET
2.0%
(47.45
)
EXISTING SPOT ELEVATION
EXISTING LOT LINE
PROPOSED CONCRETE
CROSS PAN (TYP.)
33.43
EXISTING RIGHT OF WAY
PROPOSED LOT LINE
PROPOSED RIGHT OF WAY
LEGEND:
PROPOSED GRADE BREAK
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
SEE SHEET C 502
SEE SHEET C 503SEE SHEET C 505C 501 C 502
C 503 C 504
C 506 C 505C 505
MH
UD
S
UDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMM
MHXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXUDUDUDUDUDUDUDUDTRACT AEXISTING 8' TRAILCANAL IMPORTATIONWALLENBERG DRPROPOSED
RAIN GARDEN
RAIN GARDEN BIOMEDIA AREA
(MIN. FLAT SURFACE = 4,353 SF)
CITY OF FORT COLLINS
100-YR FLOODWAY
UNDERDRAIN 1
SEE SHEET C 626
FEMA 100-YR
HIGH RISK
FLOOD FRINGE
CITY OF FORT
COLLINS 100-YR
FLOODPLAIN
8.50
8.50
8.26 (8.08)(9.62)(9.67)
10.00
(8.13)(8.00)(11.89)(11.83)(11.95)
8.50
4:1
UDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDXXXXXXXXXXXXXXXXXXXXXXXXSTWINNE GRANT R/JOHNELLE S
1821 WALLENBERG DR
ERIKSEN CHRISTOPHER M
1825 WALLENBERG DRBXBBBBBBBBBUDUD12.
7
7
EXISTING 8' TRAILCANAL IMPORTATIONTRACT A
0.5%6.79PROPOSED
RAIN GARDEN
PROPOSED 12' ACCESS ROAD
STORM DRAIN 5
SEE SHEET C 625
STORM DRAIN 5-2
SEE SHEET C 625
STORM DRAIN 3
SEE SHEET C 623
CITY OF FORT COLLINS
100-YR FLOODWAY
FEMA 100-YR
HIGH RISK
FLOOD FRINGE
CITY OF FORT
COLLINS 100-YR
FLOODPLAIN
12.
2
2
POND
OVERFLOW PATH
1
6
:
112.8612.53
12.
8
2
1.9%12.34
12.
5
912.0011.8311.8312.008.5012.8512.5012.7713.2413.14
12.9412.48
12.288.0012.13
6.858.50
2.0%0.5
%(11.95)
PROPOSED
MAINTENANCE
ACCESS PATH EMERGENCY
OVERFLOW
WEIR1.8%TIE TO EXISTING
CONCRETE TRAIL (6.76)(6.91)8.229.108.2612.806.75
12.8011.3411.529.3511.8012.8011.8011.6611.8412.4412.1912.2712.2012.357.267.8
512.0012.
1
38.0012.138.508.5012.5812.3412.8012.
7
4
12.
9
5
13.
1
0
13.
1
1
1.5%1.5%1.1%2.5%2.0%4.5%0.5%2.4%2.4%10.0%5:1
6:1
7:112.805.0%EXI
S
T
I
N
G
S
P
R
I
N
G
C
R
E
E
K
T
R
A
I
L
EX
I
S
T
I
N
G
S
P
R
I
N
G
C
R
E
E
K
T
R
A
I
L
FEMA 100-YR
FLOODWAY
EXISTING FEMA
100-YR HIGH RISK
FLOOD PLAIN
SPR
I
N
G
C
R
E
E
K
100YR ELEV. = 5011.37
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 43
C 505GRADING PLAN16
( IN FEET )
0
1 INCH = 20 FEET
20 20 40 60
NORTH
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
PROPOSED SLOPES
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL
UNKNOWN UNDERGROUND UTILITIES.
2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD 88. SEE COVER SHEET FOR
BENCHMARK REFERENCES.
4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE
FINISHED GRADE ELEVATIONS.
5.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE CITY REGULATED 100-YR
CANAL IMPORTATION FLOODPLAIN/FLOODWAY AS WELL AS THE FEMA REGULATED
SPRING CREEK 100-YR FLOODPLAIN/FLOODWAY. ANY DEVELOPMENT WITHIN THE
FLOODPLAIN MUST COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF
CITY MUNICIPAL CODE. THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT
FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE
PERMIT FEES PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF
STRUCTURES, GRADING, FILL, DETENTION PONDS, BIKE PATHS, PARKING LOTS,
UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE
CITY OF FORT COLLINS FLOODPLAIN LIMITS ARE DELINEATED ON THE FINAL
SUBDIVISION PLAT.
6.ANY CONSTRUCTION ACTIVITIES, NONSTRUCTURAL DEVELOPMENT (BRIDGES,
SIDEWALKS, CULVERTS, VEGETATION, CURB CUTS, GRADING, ETC.) IN THE
REGULATORY FLOODWAY MUST BE PRECEDED BY A NO RISE CERTIFICATION,
WHICH MUST BE PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN THE
STATE OF COLORADO.
7.NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE
FLOODWAY, WHETHER TEMPORARY (DURING CONSTRUCTION) OR PERMANENT.
8.ANY PEDESTRIAN BRIDGES IN THE FLOODWAY THAT AR NOT ABLE TO PASS THE
100-YR FLOW ARE REQUIRED TO BE "BREAKAWAY" AND TETHERED.
NOTES:
PROPOSED STORM INLET
2.0%
(47.45
)
EXISTING SPOT ELEVATION
EXISTING LOT LINE
PROPOSED CONCRETE
CROSS PAN (TYP.)
33.43
EXISTING RIGHT OF WAY
PROPOSED LOT LINE
PROPOSED RIGHT OF WAY
LEGEND:
PROPOSED GRADE BREAK
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
SEE THIS SHEET RIGHTSEE SHEET C 502SEE SHEET C 504SEE THIS SHEET LEFT
C 501 C 502
C 503 C 504
C 506 C 505C 505
CABLE
TFO FOFOFOD / / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /XSTSTSTSTSTSTSTSTSTSTSTHILL POND CONDOMINIUMS
TRACT B
FEMA 100-YR
FLOODWAY
(18.47)
EXISTING
STORM
DRAIN EXISTING SIDEWALKSPRIN
G
C
RE
EK
EXI
STI
N
G
S
P
RI
N
G
C
R
E
E
K T
R
AIL
EXISTING FEMA
100-YR HIGH RISK
FLOOD PLAIN
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 43
C 506GRADING PLAN17
( IN FEET )
0
1 INCH = 20 FEET
20 20 40 60
NORTH
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
PROPOSED SLOPES
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL
UNKNOWN UNDERGROUND UTILITIES.
2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD 88. SEE COVER SHEET FOR
BENCHMARK REFERENCES.
4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE
FINISHED GRADE ELEVATIONS.
5.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE CITY REGULATED 100-YR
CANAL IMPORTATION FLOODPLAIN/FLOODWAY AS WELL AS THE FEMA REGULATED
SPRING CREEK 100-YR FLOODPLAIN/FLOODWAY. ANY DEVELOPMENT WITHIN THE
FLOODPLAIN MUST COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF
CITY MUNICIPAL CODE. THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT
FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE
PERMIT FEES PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF
STRUCTURES, GRADING, FILL, DETENTION PONDS, BIKE PATHS, PARKING LOTS,
UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE
CITY OF FORT COLLINS FLOODPLAIN LIMITS ARE DELINEATED ON THE FINAL
SUBDIVISION PLAT.
6.ANY CONSTRUCTION ACTIVITIES, NONSTRUCTURAL DEVELOPMENT (BRIDGES,
SIDEWALKS, CULVERTS, VEGETATION, CURB CUTS, GRADING, ETC.) IN THE
REGULATORY FLOODWAY MUST BE PRECEDED BY A NO RISE CERTIFICATION,
WHICH MUST BE PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN THE
STATE OF COLORADO.
7.NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE
FLOODWAY, WHETHER TEMPORARY (DURING CONSTRUCTION) OR PERMANENT.
8.ANY PEDESTRIAN BRIDGES IN THE FLOODWAY THAT AR NOT ABLE TO PASS THE
100-YR FLOW ARE REQUIRED TO BE "BREAKAWAY" AND TETHERED.
NOTES:
PROPOSED STORM INLET
2.0%
(47.45
)
EXISTING SPOT ELEVATION
EXISTING LOT LINE
PROPOSED CONCRETE
CROSS PAN (TYP.)
33.43
EXISTING RIGHT OF WAY
PROPOSED LOT LINE
PROPOSED RIGHT OF WAY
LEGEND:
PROPOSED GRADE BREAK
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
SEE SHEET C 503
C 501 C 502
C 503 C 504
C 506 C 505C 505
E
E
E
E
E
E
E
G
G
G
G
G
G
UD
UD
UD
UD
UD
UD
UD
UD
UD
BASIN F-3.1-4
INV. OUT=5012.63 (W)
INV. OUT=5012.63 (S)
FG=5016.59
UD CO 4-3.2
INV. OUT=5012.46 (W)
FG=5016.49
BASIN 4-3 (w WEIR)
INV. IN=5011.77 (N)
INV. IN=5012.25 (E)
INV. IN=5012.33 (E)
INV. OUT=5011.77 (W)
FG=5016.34
END CHAMBER 4-3.1-3
INV. IN=5012.62 (E)
INV. OUT=5012.62 (W)
FG=5016.64
END CHAMBER 4-3.2
INV. IN=5012.52 (E)
INV. OUT=5012.52 (W)
FG=5016.54
BEGIN CHAMBER 4-3.1-2
INV. IN=5012.43 (E)
INV. OUT=5012.43 (W)
FG=5016.59
BEGIN CHAMBER 4-3.2
INV. IN=5012.34 (E)
INV. OUT=5012.34 (W)
FG=5016.45
90° BEND 4-3.3
INV. IN=5012.58 (N)
INV. OUT=5012.58 (W)
FG=5016.50
90° BEND 4-3.1-1
INV. IN=5012.42 (E)
INV. OUT=5012.42 (S)
FG=5016.57
TEE 4-3.1
INV. IN=5012.33 (E)
INV. IN=5012.33 (N)
INV. OUT=5012.35 (W)
FG=5016.43
UD BEND 4-3.1
INV. IN=5012.26 (E)
INV. OUT=5012.26 (W)
FG=5016.30
5.16 LF
4" HDPE
@ 0.20%
98.65 LF
4" PERF HDPE
@ 0.20%7.70 LF 12" HDPE @ 0.20%
1.70 LF 12" HDPE @ 0.20%
94.12 LF
SC-740 CHAMBER
@ 0.20%
4.61 LF 12" HDPE @ 1.10%
4.75 LF 12" HDPE @ 1.85%
2.54 LF
12" HDPE
@ 0.50%
92.47 LF
SC-740 CHAMBER
@ 0.20%
5.38 LF
12" HDPE
@ 0.20%
4.75 LF
12" HDPE
@ 1.10%
STORM DRAIN 4
SEE SHEET C 624
PROPOSED 8"
PVC WATER16.66FG16.68FG16.45FG16.32
FG11.99SG11.75
SG
11.95
SG
12.18
SG
0.2%
0.2%2.0%2.0%
INSPECTION PORT
INSPECTION PORT
UD UD UD UD UD UD UD
G G G G G G G G G GE
E
E E E E E E E E
G GGGEEEEEG30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W
BBBBBBBBBBBBBBBBBBBBBBBBBBASIN 2-2 (w WEIR)
INV. IN=5008.11 (N)
INV. IN=5008.52 (W)
INV. OUT=5008.11 (S)
FG=5012.84
BASIN 2-3
INV. IN=5008.12 (N)
INV. IN=5008.51 (W)
INV. OUT=5008.12 (S)
FG=5012.73
BASIN 2-4
INV. IN=5008.13 (NE)
INV. IN=5008.56 (W)
INV. OUT=5008.13 (S)
FG=5012.63
END CHAMBER 2-4.2
INV. OUT=5008.98 (E)
FG=5013.05
END CHAMBER 2-2.2
INV. OUT=5008.97 (E)
FG=5013.29
BEGIN CHAMBER 2-4.1
INV. IN=5008.59 (W)
INV. OUT=5008.59 (E)
FG=5012.67
BEGIN CHAMBER 2-2.1
INV. IN=5008.54 (W)
INV. OUT=5008.54 (E)
FG=5012.87
4.75 LF 18" RCP @ 0.20%
4.75 LF 18" RCP @ 0.20%
5.38 LF 12" HDPE @ 0.50%
64.05 LF
SC-740 CHAMBER
@ 0.60%
5.38 LF
12" HDPE
@ 0.50%
71.17 LF
SC-740 CHAMBER
@ 0.60%
STORM DRAIN 2
SEE SHEET C 623
EXISTING 30"
WATER
INSPECTION PORT
INSPECTION PORT
INSPECTION PORT
UD CO 2-3
INV. OUT=5008.96 (E)
FG=5013.35
UD TEE w CO 2-2
INV. IN=5008.57 (E)
INV. IN=5008.57 (W)
INV. OUT=5008.57 (S)
FG=5012.99
UD CO 2-2A
INV. OUT=5008.60 (W)
FG=5012.95
UD PIPE END 2-1
INV. IN=5008.07 (N)
FG=5008.07
25.39 LF
4" HDPE
@ 1.95%
5.53 LF
4" PERF HDPE
@ 0.50%
65.08 LF
4" PERF HDPE
@ 0.60%0.5%0.5%0.6%
0.6%
13.05
FG
1
2
.
5
9FG
13.00FG13.43
FG 8.46SG8.
0
0
SG8.09SG8.55SG71.17 LF
SC-740 CHAMBER
@ 0.60%
END CHAMBER 2-3.2
INV. OUT=5008.97 (E)
FG=5013.19
BEGIN CHAMBER 2-3.1
INV. IN=5008.54 (W)
INV. OUT=5008.54 (E)
FG=5012.77
5.38 LF
12" HDPE
@ 0.50%
PROPOSED SUBGRADE SPOT ELEVATION 33.43
PROPOSED SUBGRADE SLOPES 2.0%
PROPOSED SUBDRAIN UD
PROPOSED FINISHED GRADE SPOT ELEVATION 33.43
SG
1.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
2.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY
OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN
THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE
CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES
AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES.
3.CONTRACTOR SHALL NOTIFY THE DESIGN ENGINEER AND THE CITY OF FORT COLLINS
STORMWATER UTILITY A MINIMUM OF ONE WEEK IN ADVANCE SO AS TO ALLOW FOR
FIELD OBSERVATION AND DOCUMENTATION OF THE FOLLOWING SYSTEM ITEMS IN THE
SUBGRADE AREA:
- SUBGRADE
- INSTALLATION OF GEOTEXTILE FABRIC
- INSTALLATION OF UNDERDRAIN
- PLACEMENT AND COMPACTION OF SUB-BASE MATERIAL
- PLACEMENT AND COMPACTION OF BASE MATERIAL
4.STORMTECH CONTRACTOR SHALL MEET WITH SUPPLIER PRIOR TO INSTALLATION.
5.SUBGRADE AREAS ARE TO BE FIELD SURVEYED BY A LICENSED PROFESSIONAL. THE
DESIGN ENGINEER MUST CONFIRM THE SUBGRADE ELEVATIONS AND DIMENSIONS
PRIOR TO PLACEMENT OF GEOTEXTILE FABRIC, SUB-BASE, OR ANY OTHER MATERIAL.
6.THE CONTRACTOR SHOULD PROVIDE SLACK IN GEOTEXTILE FABRIC TO ENSURE
PROPER INSTALLATION AND AGGREGATE PLACEMENT WITHOUT DAMAGE. PROVIDE
SUFFICIENT SLACK SO THE FABRIC IS NOT TORN WHEN ROCK IS PLACED. IF TEARS
ARE SEEN OR DISCOVERED, REPAIR THEM AS RECOMMENDED BY MANUFACTURER
WITH NO LESS THAN 18 INCHES OF OVERLAP ON ALL SIDES OF THE TEAR.
7.THE CONTRACTOR SHALL, AT ALL TIMES DURING AND AFTER SYSTEM INSTALLATION,
PREVENT SEDIMENT, DEBRIS, AND DIRT FROM ANY SOURCE FROM ENTERING THE
VAULT SYSTEM.
8.SEE DETAIL SHEETS FOR ADDITIONAL DESIGN INFORMATION.
9.CONTRACTOR SHALL COORDINATE ANY NECESSARY TELEPHONE, CABLE, ELECTRIC,
GAS, IRRIGATION, ECT. LOWERINGS (OR RE-ROUTING) WITH THE RESPECTIVE UTILITY
PROVIDERS TO FACILITATE THE INSTALLATION OF THE PROPOSED STORM DRAIN AND
UTILITY SERVICES.
10.VAULT LAYOUT SHOWN IN THESE PLANS IS FOR REFERENCE ONLY. FINAL VAULT
LAYOUT AND DESIGN SHALL BE PER MANUFACTURER.
STORMTECH CHAMBER DETAILS
STORMTECH CHAMBER ISOLATOR ROW
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
NOTES:
W
PROPOSED CURB & GUTTER
PROPOSED FIRE HYDRANT
PROPOSED LOT LINE
PROJECT BOUNDARY
EASEMENT LINE
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 43
C 510SUBGRADE PLAN18
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
NORTH
( IN FEET )
1 inch = ft.
Feet01010
10
20 30
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
STORM
CHAMBERS 2
SHEETOFDATE:
PROJECT #:
DRAWN:
CHECKED:
THIS DRAWING HAS BEEN PREPARED BASED ON INFORMATION PROVIDED TO ADS UNDER THE DIRECTION OF THE SITE DESIGN ENGINEER OR OTHER PROJECT REPRESENTATIVE. THE SITE DESIGN ENGINEER SHALL REVIEW THIS DRAWING PRIOR TO CONSTRUCTION. IT IS THE ULTIMATE
RESPONSIBILITY OF THE SITE DESIGN ENGINEER TO ENSURE THAT THE PRODUCT(S) DEPICTED AND ALL ASSOCIATED DETAILS MEET ALL APPLICABLE LAWS, REGULATIONS, AND PROJECT REQUIREMENTS.
4640 TRUEMAN BLVD
HILLIARD, OH 43026
1-800-733-7473
ADVANCED DRAINAGE SYSTEMS, INC.
R
REV DRW CHK DESCRIPTION
01/19/16 JLM JLM UPDATE SC-740
STANDARD CROSS SECTION
11/18/14 JLM1
1JLM
70 INWOOD ROAD, SUITE 3 | ROCKY HILL | CT | 06067
860-529-8188 |888-892-2694 | WWW.STORMTECH.COM
Detention Retention Water Quality ACCEPTABLE FILL MATERIALS: STORMTECH SC-740 CHAMBER SYSTEMSPLEASE NOTE:1.THE LISTED AASHTO DESIGNATIONS ARE FOR GRADATIONS ONLY. THE STONE MUST ALSO BE CLEAN, CRUSHED, ANGULAR. FOR EXAMPLE, A SPECIFICATION FOR #4 STONE WOULD STATE: "CLEAN, CRUSHED,ANGULAR NO. 4 (AASHTO M43) STONE".2.STORMTECH COMPACTION REQUIREMENTS ARE MET FOR 'A' LOCATION MATERIALS WHEN PLACED AND COMPACTED IN 6" (150 mm) (MAX) LIFTS USING TWO FULL COVERAGES WITH A VIBRATORY COMPACTOR.3.WHERE INFILTRATION SURFACES MAY BE COMPROMISED BY COMPACTION, FOR STANDARD DESIGN LOAD CONDITIONS, A FLAT SURFACE MAY BE ACHIEVED BY RAKING OR DRAGGING WITHOUT COMPACTIONEQUIPMENT. FOR SPECIAL LOAD DESIGNS, CONTACT STORMTECH FOR COMPACTION REQUIREMENTS.NOTES:1.SC-740 CHAMBERS SHALL CONFORM TO THE REQUIREMENTS OF ASTM F2418 "STANDARD SPECIFICATION FOR POLYPROPYLENE (PP) CORRUGATED WALL STORMWATER COLLECTION CHAMBERS",OR ASTM F2922 "STANDARD SPECIFICATION FOR POLYETHYLENE (PE) CORRUGATED WALL STORMWATER COLLECTION CHAMBERS".2.SC-740 CHAMBERS SHALL BE DESIGNED IN ACCORDANCE WITH ASTM F2787 "STANDARD PRACTICE FOR STRUCTURAL DESIGN OF THERMOPLASTIC CORRUGATED WALL STORMWATER COLLECTIONCHAMBERS".3."ACCEPTABLE FILL MATERIALS" TABLE ABOVE PROVIDES MATERIAL LOCATIONS, DESCRIPTIONS, GRADATIONS, AND COMPACTION REQUIREMENTS FOR FOUNDATION, EMBEDMENT, AND FILLMATERIALS.4.THE SITE DESIGN ENGINEER IS RESPONSIBLE FOR ASSESSING THE BEARING RESISTANCE (ALLOWABLE BEARING CAPACITY) OF THE SUBGRADE SOILS AND THE DEPTH OF FOUNDATION STONEWITH CONSIDERATION FOR THE RANGE OF EXPECTED SOIL MOISTURE CONDITIONS.5.PERIMETER STONE MUST BE EXTENDED HORIZONTALLY TO THE EXCAVATION WALL FOR BOTH VERTICAL AND SLOPED EXCAVATION WALLS.6.ONCE LAYER 'C' IS PLACED, ANY SOIL/MATERIAL CAN BE PLACED IN LAYER 'D' UP TO THE FINISHED GRADE. MOST PAVEMENT SUBBASE SOILS CAN BE USED TO REPLACE THE MATERIALREQUIREMENTS OF LAYER 'C' OR 'D' AT THE SITE DESIGN ENGINEER'S DISCRETION.MATERIAL LOCATIONDESCRIPTIONAASHTO MATERIALCLASSIFICATIONSCOMPACTION / DENSITYREQUIREMENTDFINAL FILL: FILL MATERIAL FOR LAYER 'D' STARTSFROM THE TOP OF THE 'C' LAYER TO THE BOTTOMOF FLEXIBLE PAVEMENT OR UNPAVED FINISHEDGRADE ABOVE. NOTE THAT PAVEMENT SUBBASEMAY BE PART OF THE 'D' LAYERANY SOIL/ROCK MATERIALS, NATIVE SOILS, OR PERENGINEER'S PLANS. CHECK PLANS FOR PAVEMENTSUBGRADE REQUIREMENTS.N/APREPARE PER SITE DESIGN ENGINEER'S PLANS.PAVED INSTALLATIONS MAY HAVE STRINGENTMATERIAL AND PREPARATION REQUIREMENTS.CINITIAL FILL: FILL MATERIAL FOR LAYER 'C'STARTS FROM THE TOP OF THE EMBEDMENTSTONE ('B' LAYER) TO 18" (450 mm) ABOVE THETOP OF THE CHAMBER. NOTE THAT PAVEMENTSUBBASE MAY BE A PART OF THE 'C' LAYER.GRANULAR WELL-GRADED SOIL/AGGREGATE MIXTURES, <35%FINES OR PROCESSED AGGREGATE. MOST PAVEMENT SUBBASE MATERIALS CAN BE USED IN LIEUOF THIS LAYER.AASHTO M145¹A-1, A-2-4, A-3ORAASHTO M43¹3, 357, 4, 467, 5, 56, 57, 6, 67, 68, 7, 78, 8, 89,9, 10BEGIN COMPACTIONS AFTER 12" (300 mm) OFMATERIAL OVER THE CHAMBERS IS REACHED.COMPACT ADDITIONAL LAYERS IN 6" (150 mm) MAXLIFTS TO A MIN. 95% PROCTOR DENSITY FORWELL GRADED MATERIAL AND 95% RELATIVEDENSITY FOR PROCESSED AGGREGATEMATERIALS. ROLLER GROSS VEHICLE WEIGHTNOT TO EXCEED 12,000 lbs (53 kN). DYNAMICFORCE NOT TO EXCEED 20,000 lbs (89 kN).BEMBEDMENT STONE: FILL SURROUNDING THECHAMBERS FROM THE FOUNDATION STONE ('A'LAYER) TO THE 'C' LAYER ABOVE.CLEAN, CRUSHED, ANGULAR STONEAASHTO M43¹3, 357, 4, 467, 5, 56, 57NO COMPACTION REQUIRED.AFOUNDATION STONE: FILL BELOW CHAMBERSFROM THE SUBGRADE UP TO THE FOOT (BOTTOM)OF THE CHAMBER.CLEAN, CRUSHED, ANGULAR STONEAASHTO M43¹3, 357, 4, 467, 5, 56, 57PLATE COMPACT OR ROLL TO ACHIEVE A FLATSURFACE. ² ³18"(450 mm) MIN*8'(2.4 m)MAXSUBGRADE SOILS(SEE NOTE 4)PAVEMENT LAYER (DESIGNEDBY SITE DESIGN ENGINEER)SC-740END CAP6" (150 mm) MINDCBAPERIMETER STONE(SEE NOTE 6)EXCAVATION WALL(CAN BE SLOPED OR VERTICAL)12" (300 mm) MINADS GEOSYNTHETICS 601T NON-WOVEN GEOTEXTILE ALLAROUND CLEAN, CRUSHED, ANGULAR STONE IN A & B LAYERS12" (300 mm) TYP51" (1295 mm)6"(150 mm) MIN30"(760 mm)DEPTH OF STONE TO BE DETERMINEDBY SITE DESIGN ENGINEER 6" (150 mm) MIN*TO BOTTOM OF FLEXIBLE PAVEMENT. FOR UNPAVEDINSTALLATIONS WHERE RUTTING FROM VEHICLES MAY OCCUR,INCREASE COVER TO 24" (600 mm).SHEETOFDATE:
PROJECT #:
DRAWN:
CHECKED:
THIS DRAWING HAS BEEN PREPARED BASED ON INFORMATION PROVIDED TO ADS UNDER THE DIRECTION OF THE SITE DESIGN ENGINEER OR OTHER PROJECT REPRESENTATIVE. THE SITE DESIGN ENGINEER SHALL REVIEW THIS DRAWING PRIOR TO CONSTRUCTION. IT IS THE ULTIMATE
RESPONSIBILITY OF THE SITE DESIGN ENGINEER TO ENSURE THAT THE PRODUCT(S) DEPICTED AND ALL ASSOCIATED DETAILS MEET ALL APPLICABLE LAWS, REGULATIONS, AND PROJECT REQUIREMENTS.
4640 TRUEMAN BLVD
HILLIARD, OH 43026
1-800-733-7473
ADVANCED DRAINAGE SYSTEMS, INC.
R
REV DRW CHK DESCRIPTION
01/19/16 JLM JLM UPDATE SC-740
ISOLATOR ROW DETAILS
11/18/14 JLM1
1JLM
70 INWOOD ROAD, SUITE 3 | ROCKY HILL | CT | 06067
860-529-8188 |888-892-2694 | WWW.STORMTECH.COM
Detention Retention Water QualityINSPECTION & MAINTENANCESTEP 1)INSPECT ISOLATOR ROW FOR SEDIMENTA.INSPECTION PORTS (IF PRESENT)A.1.REMOVE/OPEN LID ON NYLOPLAST INLINE DRAINA.2.REMOVE AND CLEAN FLEXSTORM FILTER IF INSTALLEDA.3.USING A FLASHLIGHT AND STADIA ROD, MEASURE DEPTH OF SEDIMENT AND RECORD ON MAINTENANCE LOGA.4.LOWER A CAMERA INTO ISOLATOR ROW FOR VISUAL INSPECTION OF SEDIMENT LEVELS (OPTIONAL)A.5.IF SEDIMENT IS AT, OR ABOVE, 3" (80 mm) PROCEED TO STEP 2. IF NOT, PROCEED TO STEP 3.B.ALL ISOLATOR ROWSB.1.REMOVE COVER FROM STRUCTURE AT UPSTREAM END OF ISOLATOR ROWB.2.USING A FLASHLIGHT, INSPECT DOWN THE ISOLATOR ROW THROUGH OUTLET PIPEi)MIRRORS ON POLES OR CAMERAS MAY BE USED TO AVOID A CONFINED SPACE ENTRYii)FOLLOW OSHA REGULATIONS FOR CONFINED SPACE ENTRY IF ENTERING MANHOLEB.3.IF SEDIMENT IS AT, OR ABOVE, 3" (80 mm) PROCEED TO STEP 2. IF NOT, PROCEED TO STEP 3.STEP 2)CLEAN OUT ISOLATOR ROW USING THE JETVAC PROCESSA.A FIXED CULVERT CLEANING NOZZLE WITH REAR FACING SPREAD OF 45" (1.1 m) OR MORE IS PREFERREDB.APPLY MULTIPLE PASSES OF JETVAC UNTIL BACKFLUSH WATER IS CLEANC.VACUUM STRUCTURE SUMP AS REQUIREDSTEP 3)REPLACE ALL COVERS, GRATES, FILTERS, AND LIDS; RECORD OBSERVATIONS AND ACTIONS.STEP 4)INSPECT AND CLEAN BASINS AND MANHOLES UPSTREAM OF THE STORMTECH SYSTEM.NOTES1.INSPECT EVERY 6 MONTHS DURING THE FIRST YEAR OF OPERATION. ADJUST THE INSPECTION INTERVAL BASED ON PREVIOUSOBSERVATIONS OF SEDIMENT ACCUMULATION AND HIGH WATER ELEVATIONS.2.CONDUCT JETTING AND VACTORING ANNUALLY OR WHEN INSPECTION SHOWS THAT MAINTENANCE IS NECESSARY.SUMP DEPTH TBD BYSITE DESIGN ENGINEER(24" [600 mm] MIN RECOMMENDED)24" (600 mm) HDPE ACCESS PIPE REQUIREDUSE FACTORY PRE-FABRICATED END CAPPART #: SC740EPE24BTWO LAYERS OF ADS GEOSYNTHETICS 315WTK WOVENGEOTEXTILE BETWEEN FOUNDATION STONE AND CHAMBERS5' (1.5 m) MIN WIDE CONTINUOUS FABRIC WITHOUT SEAMSCATCH BASINORMANHOLECOVER ENTIRE ISOLATOR ROW WITH ADSGEOSYNTHETICS 601T NON-WOVEN GEOTEXTILE8' (2.4 m) MIN WIDESC-740 CHAMBERSC-740 END CAPSC-740 ISOLATOR ROW DETAILNTSOPTIONAL INSPECTION PORTSTORMTECH HIGHLY RECOMMENDSFLEXSTORM PURE INSERTS IN ANY UPSTREAMSTRUCTURES WITH OPEN GRATESSC-740 6" INSPECTION PORT DETAILNTSSC-740 CHAMBERFLEXSTORM CATCH ITPART# 6212NYFXWITH USE OF OPEN GRATE12" (300 mm) NYLOPLAST INLINEDRAIN BODY W/SOLID HINGEDCOVER OR GRATEPART# 2712AG6NIPSOLID COVER: 1299CGCGRATE: 1299CGS6" (150 mm) INSERTA TEEPART#6IPSSWST74IPINSERTA TEE TO BE CENTEREDON CORRUGATION CREST6" (150 mm) DWV SCH40PIPE (BY OTHERS)18" (450 mm) MIN WIDTHCONCRETE SLAB8" (200 mm) MIN THICKNESSPAVEMENTCONCRETE COLLAR NOT REQUIREDFOR UNPAVED APPLICATIONSCONCRETE COLLARPART #STUB A B C
SC740EPE06T / SC740EPE06TPC 6" (150 mm)10.9" (277 mm)18.5" (470 mm)---
SC740EPE06B / SC740EPE06BPC ---0.5" (13 mm)
SC740EPE08T /SC740EPE08TPC 8" (200 mm)12.2" (310 mm)16.5" (419 mm)---
SC740EPE08B / SC740EPE08BPC ---0.6" (15 mm)
SC740EPE10T / SC740EPE10TPC 10" (250 mm)13.4" (340 mm)14.5" (368 mm)---
SC740EPE10B / SC740EPE10BPC ---0.7" (18 mm)
SC740EPE12T / SC740EPE12TPC 12" (300 mm)14.7" (373 mm)12.5" (318 mm)---
SC740EPE12B / SC740EPE12BPC ---1.2" (30 mm)
SC740EPE15T / SC740EPE15TPC 15" (375 mm)18.4" (467 mm)9.0" (229 mm)---
SC740EPE15B / SC740EPE15BPC ---1.3" (33 mm)
SC740EPE18T / SC740EPE18TPC 18" (450 mm)19.7" (500 mm)5.0" (127 mm)---
SC740EPE18B / SC740EPE18BPC ---1.6" (41 mm)
SC740EPE24B*24" (600 mm)18.5" (470 mm)---0.1" (3 mm)
ALL STUBS, EXCEPT FOR THE SC740EPE24B ARE PLACED AT BOTTOM OF END CAP SUCH THAT THE OUTSIDE DIAMETER OF
THE STUB IS FLUSH WITH THE BOTTOM OF THE END CAP. FOR ADDITIONAL INFORMATION CONTACT STORMTECH AT
1-888-892-2694.
* FOR THE SC740EPE24B THE 24" (600 mm) STUB LIES BELOW THE BOTTOM OF THE END CAP APPROXIMATELY 1.75" (44 mm).
BACKFILL MATERIAL SHOULD BE REMOVED FROM BELOW THE N-12 STUB SO THAT THE FITTING SITS LEVEL.
NOTE: ALL DIMENSIONS ARE NOMINAL
NOMINAL CHAMBER SPECIFICATIONS
SIZE (W X H X INSTALLED LENGTH)51.0" X 30.0" X 85.4" (1295 mm X 762 mm X 2169 mm)
CHAMBER STORAGE 45.9 CUBIC FEET (1.30 m³)
MINIMUM INSTALLED STORAGE*74.9 CUBIC FEET (2.12 m³)
WEIGHT 75.0 lbs.(33.6 kg)
*ASSUMES 6" (152 mm) STONE ABOVE, BELOW, AND BETWEEN CHAMBERS
STUBS AT BOTTOM OF END CAP FOR PART NUMBERS ENDING WITH "B"
STUBS AT TOP OF END CAP FOR PART NUMBERS ENDING WITH "T"
SC-740 TECHNICAL SPECIFICATION
NTS
90.7" (2304 mm) ACTUAL LENGTH 85.4" (2169 mm)
INSTALLED LENGTH
OVERLAP NEXT CHAMBER HERE
(OVER SMALL CORRUGATION)
BUILD ROW IN THIS DIRECTION
START END
A A
C
B
51.0"
(1295 mm)
30.0"
(762 mm)
ACCEPTS 4" (100 mm) SCH 40 PVC PIPE FOR INSPECTION
PORT. FOR PIPE SIZES LARGER THAN 4" (100 mm) UP TO
10" (250 mm) USE INSERTA TEE CONNECTION CENTERED
ON A CHAMBER CREST CORRUGATION
45.9" (1166 mm)12.2"
(310 mm)
29.3"
(744 mm)
STORM CHAMBERS 2 STORM CHAMBERS 1
FG
STORM
CHAMBERS 1
V.P.
CABLE
F.O.HY DVAULT
ELEC
VAULT
ELECVAULT
ELEC
T
E
S
S
MH
S
SSS
S
S
T S
H2O
TRAFFIC
VAULTT SVAULT
ELEC
S
VAULT
ELEC
VAULT
ELEC
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
ELEC
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
S
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR HY DS
15" SS18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS
21" SS
21" SS21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS8" SS8" SS 8" SS 8" SSEEEEEEEEEETTTTTTTTGGGGGGGGGGGWW W W W W W W
12" W12" W12" W12" W12" W12" WEFOEEEEEEEEEGGGGGG30" W30" W30" W30" W30" W30" W30" W36" W36" W36" WFDC
FS UDE
E
E
E E UDU
D
U
D
U
D
U
DUDUD
UD
UD UD UD UD UDSSSSWWW
S
S
UDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDD
F.O.
D
S
S
HY DMH
S
HY DMM
MH
ELEC
/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /XX30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W
XXXXXXXXXXXXSTSTSTSTSTSS
30" W
S
SSSSSSSSSSSSSS2
1
"
S
S
2
1
"
S
S
2
1
"
S
S
BBBBBBBBBBBBBB BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBXXBBBBBBBBBXXXXXE
E
E
E
G G G G G
G
G
G
G GEEETTGTE E
TTG
TT
TE
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELECEEEEEEE UDUDUDUD
G GEEE
G G G
UD
EEEE E E E EE E
E E E
G
GGGGE E E E
EEEEEE E E
G G G G G G
ETEE E
TE E
FDC
FDC FDCFDCFDC FDC
FDC
FDC GGGGGGGGGGGGGGGG G G G
G GTS SHIELDS ST.HOBBIT ST.WALLENBERG DR.FEMA 100-YR
HIGH RISK
FLOOD FRINGE
EXISTING 21" CLAY
SANITARY SEWER
EXISTING 18" CLAY
SANITARY SEWER
PROPOSED 8"
PVC WATER
(PHASE 1)
EXISTING WATERLINEEXISTING 12" WATERLINE
EXISTING 12" WATERLINE
EXISTING 36" WATERLINE
EXISTING ELECTRIC
VAULT (TYP.)
EXISTING 8" PVC
SANITARY SEWER
EXISTING 15"
SANITARY SEWER
EXISTING
UNDERDRAIN
4' SANITARY
MANHOLE (TYP.)
PROPOSED FIRE
HYDRANT
(PHASE 1)
PROPOSED FIRE
HYDRANT
PROPOSED FIRE
HYDRANT
PROPOSED FIRE
HYDRANT
33' WATERLINE EASEMENT
48' SANITARY SEWER EASEMENT
PROPOSED 2'
CONCRETE PAN
PROPOSED 2'
CONCRETE PAN
PROPOSED 2'
SIDEWALK
CHASE PROPOSED 2'
SIDEWALK CHASE
PROPOSED FIRE
HYDRANT
(PHASE 1)
PROPOSED OUTLET
STRUCTURE
RAIN GARDEN
BIOMEDIA AREA
SPRING CREEK EXIST
ING
8
'
TRA
IL
EXISTI
N
G
S
P
R
I
N
G
C
R
E
E
K
T
R
A
I
L
NATURAL AREA
BUFFER
LOT 1
TRACT B
TRACT A
TRACT C
PROPOSED FIRE
HYDRANT
(PHASE 1)CANAL IMPORTATIONCONNECT TO EXISTING
WATER LINE
(PHASE 1)
CONNECT TO
EXISTING
WATER LINE
(PHASE 1)
CONNECT TO EXISTING
WATER LINE
CONNECT TO EXISTING
WATER LINE
EXISTING FIRE HYDRANT
PROPOSED 8" PVC
WATER (PHASE 1)
EXISTING FIRE HYDRANT
CONNECT TO
EXISTING SANITARY
(PHASE 1)
CONNECT TO
EXISTING SANITARY CONNECT TO
EXISTING SANITARY
EXISTING FIRE HYDRANT
CONNECT TO
EXISTING SANITARYCONNECT TO
EXISTING SANITARY
EXISTING 26" STORM
EXISTING 30" STORM
EXISTING 18" CLAY
SANITARY SEWER
PROPOSED FIRE
HYDRANT
PROPOSED 2'
CONCRETE PAN
PROPOSED 2'
CONCRETE PAN
PROPOSED RETAINING
WALL (TYP.)
SANITARY LINE A
SEE SHEET C 610
(PHASE 1)
SANITARY LINE D
SEE SHEET C 612
SANITARY LINE C
SEE SHEET C 612
STORM DRAIN 1
SEE SHEET C 620
PROPOSED 4'
SIDEWALK
CULVERT
FEMA 100-YR
FLOODWAY
CITY OF FORT COLLINS
100-YR FLOODWAY
FEMA 100-YR
HIGH RISK
FLOOD FRINGE
CITY OF FORT
COLLINS 100-YR
FLOODPLAIN
SANITARY LINE A3
SEE SHEET C 610
(PHASE 1)
STORM DRAIN 4-4
SEE SHEET C 624
STORM DRAIN 4-4A
SEE SHEET C 624
STORM DRAIN 4
SEE SHEET C 624
STORM DRAIN 1-9
SEE SHEET C 622 STORM DRAIN 1-8
SEE SHEET C 622
STORM DRAIN 5
SEE SHEET C 625
STORM DRAIN 5
SEE SHEET C 625
STORM DRAIN 5-2
SEE SHEET C 625
PROPOSED 8"
PVC WATER
STORM DRAIN 2
SEE SHEET C 623
STORM DRAIN 3
SEE SHEET C 623
STORM DRAIN 6
SEE SHEET C 626
UNDERDRAIN
SEE SHEET C 626
PROPOSED 2'
CONCRETE PAN
CONNECT TO
EXISTING
WATER LINE
(PHASE 1)
W STUART ST.
STORM DRAIN 1-5
SEE SHEET C 621
STORM DRAIN 1-6
SEE SHEET C 621
BUILDING 6 BUILDING 7
BUILDING 2
BUILDING 3
BUILDING 4
BUILDING 5
BUILDING 8BUILDING 18BUILDING 17BUILDING 16BUILDING 15BUILDING 14
BUILDING 13
BUILDING 12
BUILDING 11
BUILDING 10
BUILDING 9
BUILDING 1
PROPOSED 2'
SIDEWALK CHASE
PROPOSED STORM
CHAMBERS 2
END PHASE
1 WATER
SANITARY LINE B
SEE SHEET C 611
SANITARY LINE B3
SEE SHEET C 611
CULVERTS
SEE SHEET U1-U4
CULVERT
SEE SHEET U1-U4
CULVERTS
SEE SHEET U1-U4
CULVERT
SEE SHEET U1-U4
AREA DRAINS
SEE SHEET U1-U4
AREA DRAINS
SEE SHEET U1-U4
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 43
C 600OVERALL UTILITY PLAN19CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
NORTH
( IN FEET )
1 inch = ft.
Feet06060
60
120 180
NOTES:
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY
OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN
THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE
CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES
AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES.
2.ALL WATER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITIES
SPECIFICATIONS , LATEST EDITION, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS
ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR
AS REQUIRED FOR ABNORMAL DEFLECTIONS.
3.ALL SEWER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY
SPECIFICATIONS SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST
EDITION.
4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE
NOT TO SCALE.
5.ALL WATERLINES SHALL HAVE A 4.5'-5' COVER FROM FINISHED GRADE TO TOP OF PIPE.
6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS
SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND
ARE SUBJECT TO CHANGE IN THE FIELD.
7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
SANITARY SEWER MAINS, WATER MAINS & SERVICES.
8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN
THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO
BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS.
10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 1 4"
BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO
PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
11.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE CITYREGULATED, 100YEAR
CANAL IMPORTATION FLOODPLAIN/FLOODWAY AS WELL AS THE FEMA REGULATED
SPRING CREEK 100YEAR FLOODPLAIN/FLOODWAY. ANY DEVELOPMENT WITHIN THE
FLOODPLAIN MUST COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF CITY
MUNICIPAL CODE. THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM
THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE PERMIT FEES
PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES,
GRADING, FILL, DETENTION PONDS, BIKE PATHS, PARKING LOTS, UTILITIES,
LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE CITY OF FORT
COLLINS FLOODPLAIN LIMITS AS DELINEATED ON THE FINAL SUBDIVISION PLAT
12.ANY CONSTRUCTION ACTIVITIES, NONSTRUCTURAL DEVELOPMENT (BRIDGES,
SIDEWALKS, CULVERTS, VEGETATION, CURBCUTS, GRADING, ETC.) IN THE
REGULATORY FLOODWAY MUST BE PRECEDED BY A NORISE CERTIFICATION, WHICH
MUST BE PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF
COLORADO.
13.NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE FLOODWAY,
WHETHER TEMPORARY (DURING CONSTRUCTION) OR PERMANENT.
14. ANY PEDESTRIAN BRIDGES IN THE FLOODWAY THAT ARE NOT ABLE TO PASS THE 100
YEAR FLOW ARE REQUIRED TO BE “BREAKAWAY” AND TETHERED.
15. A BLANKET UTILITY EASEMENT EXISTS ACROSS THE PROJECT BOUNDARY WHERE
OTHER EASEMENTS ARE NOT PRESENT.
16. WATER AND FIRE SERVICES MUST HAVE A MINIMUM OF 4.5 FET OF COVER AND A
MINIMUM OF 18" VERTICAL CLEARANCE FROM STORM SEWERS. ANY STORM SEWER
SHALLOWER THAN 5.0 FET WILL REQUIRE THE WATER SERVICE TO BE INSTALLED
UNDER THE PROPOSED STORM SEWER.
EXISTING LOT LINE
EASEMENT LINE
SPROPOSED SEWER SERVICE
WPROPOSED WATER SERVICE
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
G
T
EXISTING STORM SEWER
EXISTING TELEPHONE
EXISTING GAS
EXISTING SANITARY SEWER
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPERTY BOUNDARY
EXISTING TELEPHONE PEDESTAL
PROPOSED STREET LIGHT
W
SS
PROPOSED LOT LINE
PROPOSED ROW
EXISTING ROW
EXISTING CABLE CTV
PROPOSED WATER MAIN (PHASE 1)
PROPOSED SANITARY SEWER (PHASE 1)
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
C 601 C 602
C 603 C 604
HY DVAULT
ELEC
SS
SSS
TRAFFIC
VAULTT SVAULT
ELEC
S
VAULT
ELEC
VAULT
ELEC
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
ELEC
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
S
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR HY DS
15" SS15" SS18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS
21" SS 21" SS 21" SS
21" SS21" SS21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS8" SS8
"
S
S
8" SS 8" SS 8" SS 8" SS 8" SS8" SSEEEEEEEEEEEEEEEEEEEEETTTTTTTTTTTTTTTTTGGGGGGGGGGGGGGGGGGGGGWWEW W W W W W W W W W W W W W WW
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WWEEEEEEE15" SS30" W36" W36" W36" W36" WWWWUDUDUDUD
W W W W W
/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W
EXISTING 8" WATERLINE
EXISTING 18" CLAY
SANITARY SEWER
EXISTING 12" WATERLINE
EXISTING 12" WATERLINE
EXISTING 36" WATERLINE
EXISTING ELECTRIC
VAULT (TYP.)
28.5' HALF ROW
EXISTING 8" PVC
SANITARY SEWER
SSSS
SSWWWFFFFFFE
E
E
E
G
G
G GEGG
GTEE
E
TTGG G
TT
TSEEE
E
VAULT
ELEC
VAULT
ELEC
EEEEEE E E E E E
EEEEWUD EE E E E
E E E E E
E E E E E E E E
EEEEWE
E E E E E E
G G G G G G G
G G G G G G G
SSEEFDC
FDC FDCFDCFDC FDC
FDCIR W
G GGGGGGGGGGGGGGGGGGGGGGGGG G G G G G G G GG G GTEPROPOSED 8"
PVC WATER
(PHASE 1)
EXISTING 15"
SANITARY SEWER
PROPOSED SANITARY
SERVICE (TYP.)
PROPOSED FIRE
SERVICE (TYP.)
PROPOSED WATER
SERVICE (TYP.)
31'
FL-FL
26'
FL-FL
26'
FL-FL
26'
FL-FL
26'
FL-FL
26'
FL-FL
EXISTING 30" WATERLINE
PROPOSED 2'
CONCRETE PAN
PROPOSED 2'
CONCRETE PAN
PROPOSED 2'
CONCRETE PAN
EXISTING 21" CLAY
SANITARY SEWER
PROPOSED
FIRE HYDRANT
PROPOSED 2'
SIDEWALK
CHASE
PROPOSED 2'
SIDEWALK CHASE
26' EMERGENCY
ACCESS
EASEMENT
26' EMERGENCY
ACCESS
EASEMENT
26' EMERGENCY
ACCESS
EASEMENT
26' EMERGENCY
ACCESS
EASEMENT
31' EMERGENCY
ACCESS
EASEMENT
26' EMERGENCY
ACCESS
EASEMENT
33' WATERLINE
EASEMENT
PROPOSED FIRE
HYDRANT (PHASE 1)
PROPOSED FIRE
HYDRANT
PROPOSED FIRE
HYDRANT
EXISTING 8" PVC
WATER
EXISTING
UNDERDRAIN
EXISTING FIRE
HYDRANT
EXISTING
SERVICES
INSTALL NEW MANHOLE
CONNECT TO EXISTING
SANITARY SEWER
NEW MH CONNECTIONS TO
EXISTING SANITARY SHALL
BE MADE W/ PRECAST MH
(PHASE 1)
PROPOSED 2'
CONCRETE PAN
SANITARY LINE A
SEE SHEET C 610
(PHASE 1)
STORM DRAIN 1
SEE SHEET C 620
PROPOSED
IRRIGATION SERVICE
PROPOSED
STORM CHAMBERS 2
STORM DRAIN 4-4
SEE SHEET C 624
STORM DRAIN 4-4A
SEE SHEET C 624
STORM DRAIN 4
SEE SHEET C 624
STORM DRAIN 1-9
SEE SHEET C 622
STORM DRAIN 1-8
SEE SHEET C 622
SANITARY LINE A3
SEE SHEET C 610
(PHASE 1)
SANITARY LINE B3
SEE SHEET C 611
BUILDING 6 BUILDING 7
BUILDING 2
BUILDING 3
BUILDING 4 BUILDING 5
BUILDING 1
PROPOSED 2'
SIDEWALK CHASE
PROPOSED 2'
SIDEWALK CHASE
PROPOSED 2'
CONCRETE PAN
PROPOSED 2'
SIDEWALK CHASE
8" x 6" SWIVEL TEE
1 - 6" GV (E)
END PHASE 1 WATER
STA.=12+28.56
N: 1449222.36
E: 3113257.18
90° BEND w/ TB
STA.=12+58.72
N: 1449252.53
E: 3113257.19
8" x 6" TEE
1 - 6" GV (S)
STA.=14+38.64
N: 1449252.43
E: 3113437.12
8" TEE w/ TB
2 - 8" GV (E, S)
STA.=17+41.42
N: 1449296.99
E: 3113695.22
8" x 6" TEE w/ TB
1 - 6" GV (W)
STA.=10+45.61
N: 1449039.41
E: 3113257.08
8" x 6" TEE w/ TB
1 - 6" GV (E)
STA.=10+55.61
N: 1449049.41
E: 3113257.09
8" x 6" SWIVEL TEE
1 - 6" GV (W)
STA.=10+22.56
N: 1449016.36
E: 3113257.07
8" x 6" TEE w/ TB
1 - 6" GV (S)
STA.=15+22.10
N: 1449252.39
E: 3113520.57
8" x 6" TEE w/ TB
1 - 6" GV (S)
STA.=16+22.28
N: 1449252.34
E: 3113620.75
PROPOSED 1'
SIDEWALK CHASE
PROPOSED 1'
SIDEWALK CHASE
PROPOSED 2'
SIDEWALK CHASE
PROPOSED 1'
SIDEWALK CHASE
PROPOSED 2'
SIDEWALK CHASE
6' SIDEWALK6' SIDEWALK
6' SIDEWALK6' SIDEWALK 6' SIDEWALK
6' SIDEWALK 9' SIDEWALK9' SIDEWALK
8' SIDEWALK
4.5' SIDEWALK
S SHIELDS ST.HOBBIT ST.
4.5' SIDEWALK
5' SIDEWALK9' SIDEWALK6' SID
E
W
A
L
K
6' SIDEWALKEXISTING SIDEWALKLOT 1
LOT 1 9' SIDEWALK9' SIDEWALKPROPOSED 2'
SIDEWALK CHASE
PROPOSED 1'
SIDEWALK CHASE
PROPOSED 1'
SIDEWALK CHASE
TEE 1-9.4
INV.=5011.12
FG=5015.49
12.56 LF
6" HDPE
@ 0.53%
INLET 1-9.4.1
INV.=5011.13
FG=5015.10
11.86 LF
8" HDPE
@ 0.49%
PIPE END B4
INV.=5018.27
FG=5018.27
PIPE END B3
FG=5018.23
PIPE END B2
INV.=5018.16
FG=5018.16
PIPE END B1
FG=5018.12
19.14 LF
12" HDPE
@ 0.50%
14.85 LF
12" HDPE
@ 2.15%
17.02 LF
12" HDPE
@ 0.50%
17.37 LF
12" HDPE
@ 0.50%
0.00 LF8" HDPE@ 0.00%
17.49 LF
8" HDPE
@ 0.50%
16.73 LF
8" HDPE
@ 0.50%
13.41 LF
8" HDPE
@ 0.50%
8.01 LF
8" HDPE
@ 0.50%
TEE 1-9.3
INV.=5010.98
FG=5015.21
INLET 1-9.3-1
INV.=5011.51
FG=5015.24
TEE 1-9.2
INV.=5010.89
FG=5015.08 13.78 LF
8" HDPE
@ 0.45%
INLET 1-9.2-1
INV.=5011.08
FG=5015.17
2.05 LF
8" HDPE
@ 0.50%
INLET 1-9.7-1
INV.=5011.61
FG=5015.33
TEE 1-9.7
INV.=5011.34
FG=5015.58
3.04 LF
8" HDPE
@ 0.50%
INLET 1-9.8-1
INV.=5011.61
FG=5015.33
TEE 1-9.8
INV.=5011.44
FG=5015.68
3.96 LF
8" HDPE
@ 0.50%
INLET 1-9.10-1
INV.=5011.48
FG=5015.21
TEE 1-9.10
INV.=5011.69
FG=5015.35
31.29 LF
8" HDPE
@ 0.50%
INLET 1-9.11
INV.=5011.85
FG=5014.97
PIPE END A11
INV.=5017.76
FG=5017.76
PIPE END A10
FG=5017.69
PIPE END A9
INV.=5017.41
FG=5017.41
INLET A8
INV.=5017.32
FG=5018.36
PIPE END A7
INV.=5013.49
FG=5017.24
PIPE END A6
INV.=5017.14
FG=5017.14
INLET A5
INV.=5017.06
FG=5018.37
PIPE END A4
FG=5016.97
PIPE END A3
INV.=5016.69
FG=5016.69
INLET A2
INV.=5016.37
FG=5017.76
PIPE END A1
FG=5016.27
TEE 4-4.1
INV.=5013.22
FG=5016.30
42.93 LF
8" HDPE
@ 0.50%
INLET 4-4.1-1
INV.=5013.43
FG=5016.21
23.65 LF
8" HDPE
@ 0.50%
INLET 4-4.1-2
INV.=5013.55
FG=5016.26
INLET 1-6.2-4
INV.=5010.60
FG=5013.01
36.72 LF 8" HDPE @ 0.40%
BEND 1-6.2-3
INV.=5010.46
FG=5014.83
16.77 LF 8" HDPE @ 0.40%
BEND 1-6.2-2
INV.=5010.39
FG=5014.85
11.67 LF 8" HDPE @ 0.40%
BEND 1-6.2-1
INV.=5010.34
FG=5014.88
87.57 LF 8" HDPE @ 1.00%
TEE 1-9.9-1
INV.=5012.54
FG=5016.61
4.51 LF
8" HDPE
@ 2.00%
INLET 1-9.9-1.1
INV.=5012.63
FG=5016.25
39.23 LF
8" HDPE
@ 1.00%
4.51 LF
8" HDPE
@ 2.00%
INLET 1-9.9-2.1
INV.=5013.02
FG=5016.25
TEE 1-9.9-2
INV.=5012.93
FG=5016.60
54.74 LF 8" HDPE @ 1.00%
BEND 1-9.9-3
INV.=5013.48
FG=5016.90
12.06 LF
8" HDPE
@ 1.00%
INLET 1-9.9-4
INV.=5013.60
FG=5016.20
PROPOSED 1'
SIDEWALK CHASE PROPOSED 2'
SIDEWALK CHASE
PROPOSED 2'
SIDEWALK CHASE
PROPOSED 1'
SIDEWALK CHASE
3.79 LF 8" HDPE @ 2.00%
INLET 1-12.1
INV.=5013.14
FG=5016.17
TEE 1-12
INV.=5013.06
FG=5016.88
8.01 LF
8" HDPE
@ 0.50%
INLET 4-4.6-1
INV.=5014.04
FG=5016.92
4.08 LF 6" HDPE @ 0.50%
4.86 LF 8" PVC
S23°40'29"W
38.44 LF 8" PVCS23°40'29"W22.56 LF 8" PVC
N00°01'50"E 206.00 LF 8" PVCN00°01'50"E30.17 LF 8" PVC
N00°01'50"E
179.92 LF 8" PVC
S89°58'10"E
258.08 LF 8" PVC
S89°58'10"E
44.69 LF 8" PVC
N00°01'50"E
STORM DRAIN 1
SEE SHEET C 620
PROPOSED 2'
CONCRETE PAN
13.50 LF 6" PVC
N89°56'33"E
28.56 LF 6" PVC
S00°00'00"E
35.31 LF 6" PVC
N00°00'00"E
CONNECT TO EXISTING 8" WATER
8"x6" TAPPING SADDLE w/ 6" GV (S) & TB
N:1449454.28
E:3113341.26
CONNECT TO EXISTING 8" WATER
8"x6" TAPPING SADDLE w/ 6" GV (S) & TB
N:1449452.76
E:3113606.06
35.31 LF 6" PVC
S00°00'00"E
WATER
LOWERING
28.58 LF 6" PVC
S00°00'00"E
68.57 LF 6" PVC
N90°00'00"E
SANITARY LINE A
SEE SHEET C 610
(PHASE 1)
22.15 LF 6" PVC
N90°00'00"E
WATER
LOWERING
CONNECT TO EXISTING 30" WATER
30"x8" TAPPING SADDLE w/ 8" GV (N) & TB
(PHASE 1)
STA.=10+00.00
N: 1448993.81
E: 3113257.06
CONNECT NEW
IRRIGATION SERVICE
TO EXISTING CITY
PARKWAY SYSTEM
34.85 LF 6" PVC
S00°00'00"E
NOTES:
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY
OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN
THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE
CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES
AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES.
2.ALL WATER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITIES
SPECIFICATIONS , LATEST EDITION, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS
ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR
AS REQUIRED FOR ABNORMAL DEFLECTIONS.
3.ALL SEWER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY
SPECIFICATIONS SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST
EDITION.
4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE
NOT TO SCALE.
5.ALL WATERLINES SHALL HAVE A 4.5'-5' COVER FROM FINISHED GRADE TO TOP OF PIPE.
6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS
SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND
ARE SUBJECT TO CHANGE IN THE FIELD.
7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
SANITARY SEWER MAINS, WATER MAINS & SERVICES.
8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN
THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO
BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS.
10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 1 4"
BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO
PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
11.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE CITYREGULATED, 100YEAR
CANAL IMPORTATION FLOODPLAIN/FLOODWAY AS WELL AS THE FEMA REGULATED
SPRING CREEK 100YEAR FLOODPLAIN/FLOODWAY. ANY DEVELOPMENT WITHIN THE
FLOODPLAIN MUST COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF CITY
MUNICIPAL CODE. THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM
THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE PERMIT FEES
PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES,
GRADING, FILL, DETENTION PONDS, BIKE PATHS, PARKING LOTS, UTILITIES,
LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE CITY OF FORT
COLLINS FLOODPLAIN LIMITS AS DELINEATED ON THE FINAL SUBDIVISION PLAT
12.ANY CONSTRUCTION ACTIVITIES, NONSTRUCTURAL DEVELOPMENT (BRIDGES,
SIDEWALKS, CULVERTS, VEGETATION, CURBCUTS, GRADING, ETC.) IN THE
REGULATORY FLOODWAY MUST BE PRECEDED BY A NORISE CERTIFICATION, WHICH
MUST BE PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF
COLORADO.
13.NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE FLOODWAY,
WHETHER TEMPORARY (DURING CONSTRUCTION) OR PERMANENT.
14. ANY PEDESTRIAN BRIDGES IN THE FLOODWAY THAT ARE NOT ABLE TO PASS THE 100
YEAR FLOW ARE REQUIRED TO BE “BREAKAWAY” AND TETHERED.
15. A BLANKET UTILITY EASEMENT EXISTS ACROSS THE PROJECT BOUNDARY WHERE
OTHER EASEMENTS ARE NOT PRESENT.
16. WATER AND FIRE SERVICES MUST HAVE A MINIMUM OF 4.5 FET OF COVER AND A
MINIMUM OF 18" VERTICAL CLEARANCE FROM STORM SEWERS. ANY STORM SEWER
SHALLOWER THAN 5.0 FET WILL REQUIRE THE WATER SERVICE TO BE INSTALLED
UNDER THE PROPOSED STORM SEWER.
EXISTING LOT LINE
EASEMENT LINE
SPROPOSED SEWER SERVICE
WPROPOSED WATER SERVICE
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
G
T
EXISTING STORM SEWER
EXISTING TELEPHONE
EXISTING GAS
EXISTING SANITARY SEWER
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPERTY BOUNDARY
EXISTING TELEPHONE PEDESTAL
PROPOSED STREET LIGHT
W
SS
PROPOSED LOT LINE
PROPOSED ROW
EXISTING ROW
EXISTING CABLE CTV
PROPOSED WATER MAIN (PHASE 1)
PROPOSED SANITARY SEWER (PHASE 1)
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 43
C 601UTILITY PLAN20
( IN FEET )
0
1 INCH = 30 FEET
30 30 60 90
NORTH
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
C 601 C 602
C 603 C 604
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
SEE SHEET C 603 SEE SHEET C 602
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBXXXXXXBBBBBBBBBXXXXXXXXXXXXV.P.
S
S
MH
S
S18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS
21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SS 21" SSXFDC
F UDE E E E
U
D
U
D
U
D
U
D
U
DUDUDUD
UD
UD
UD UD UD UD UD UD UD UD UD UDSS
W W W W
S
S
UDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDS
HY DMH
S
HY D
MM
MH
30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W
XXXXXXXXXXXXXXXXXXXXXSSSS
30" W 30" W
WINNE GRANT R/JOHNELLE S
1821 WALLENBERG DR
2
1
"
S
S
2
1
"
S
S
2
1
"
S
S
2
1
"
S
S
2
1
"
S
S
2
1
"
S
SSSSWWFF
E
E
E
G
G
G GGEEEEEETTGG
GEE
E E
E
TES
WWWW
WFSS
VAULT
ELECEEEE UDUDUDUDUDUDW
UD UD
G G G GEEEE
E E
G G G G G G
EEE E E E E GG G G
GGGGGGGGGW
GEEEEEEE18" SS
WE E
W
WSTE EEE E E
TE E E E E E
FDCFDC
FDCGG FFFFG
GGG
SSSFSFFFSFWFGGGGGGGG G G G
PROPOSED SANITARY
SERVICE (TYP.)
PROPOSED SANITARY
SERVICE (TYP.)
26'
FL-FL
26'
FL-FL
26'
FL-FL
PROPOSED
RAIN GARDEN
PROPOSED
FIRE HYDRANT
PROPOSED
FIRE HYDRANT
26' EMERGENCY
ACCESS
EASEMENT
26' EMERGENCY
ACCESS
EASEMENT
26' EMERGENCY
ACCESS
EASEMENT
33' WATERLINE
EASEMENT
RAIN GARDEN
BIOMEDIA AREA
FEMA 100-YR
HIGH RISK
FLOOD FRINGE
CITY OF FORT
COLLINS 100-YR
FLOODPLAIN
NATURAL AREA
BUFFER
EXISTING 8" PVC
WATER
EXISTING
UNDERDRAIN
PROPOSED 8"
PVC WATER
(PHASE 1)
CONNECT TO EXISTING
SANITARY SEWER MANHOLE
EXISTING FH
EXISTING FH
EXISTING 30"
WATERLINE
CONNECT TO
EXISTING
WATERLINE
PROPOSED 2'
SIDEWALK CHASE
PROPOSED 2'
CONCRETE PAN w/
6" CURBS
NEW MH CONNECTIONS TO
EXISTING SANITARY SHALL
BE MADE W/ PRECAST MH
NEW MH CONNECTIONS TO
EXISTING SANITARY SHALL
BE MADE W/ PRECAST MH
SANITARY LINE D
SEE SHEET C 612
SANITARY LINE C
SEE SHEET C 612
STORM DRAIN 1
SEE SHEET C 620
PROPOSED 2'
CONCRETE PAN
PROPOSED
RETAINING WALL
(TYP.)
PROPOSED
RETAINING WALL
(TYP.)
PROPOSED WATER SERVICE
w/ INTERNAL METER (TYP.)
PROPOSED WATER SERVICE
w/ INTERNAL METER (TYP.)
PROPOSED STORM
CHAMBERS 1
NATURAL AREA
BUFFER
CITY OF FORT COLLINS
100-YR FLOODWAY
STORM DRAIN 3
SEE SHEET C 623
STORM DRAIN 2
SEE SHEET C 623
STORM DRAIN 5
SEE SHEET C 625
STORM DRAIN 5-2
SEE SHEET C 625
UNDERDRAIN
SEE SHEET C 626
SANITARY LINE B
SEE SHEET C 611
SANITARY LINE B3
SEE SHEET C 611
BENCH TO BE
CHANNELIZED
FOR SERVICE
PROPOSED 2'
CONCRETE PAN w/
6" CURBS
UTILITY EASEMENT
EXCLUSION
UTILITY EASEMENT
EXCLUSION
BUILDING 5 BUILDING 8
BUILDING 18 BUILDING 17
BUILDING 16 BUILDING 15
BUILDING 14
BUILDING 13
BUILDING 12
BUILDING 11
BUILDING 10
BUILDING 9
PROPOSED
FOREBAY
PROPOSED 2'
CONCRETE PAN
STORM DRAIN 1-5
SEE SHEET C 621
STORM DRAIN 1-6
SEE SHEET C 621
90° BEND w/ TB
STA.=16+96.72
N: 1449252.30
E: 3113695.19
8" TEE w/ TB
2 - 8" GV (E, S)
STA.=17+41.42
N: 1449296.99
E: 3113695.22
8" x 6" SWIVEL TEE
1 - 6" GV (W)
STA.=18+18.53
N: 1449374.10
E: 3113695.27
8" TEE
1 - 8" GV (S)
STA.=18+96.24
N: 1449451.81
E: 3113695.30
90° BEND
STA.=11+56.78
N: 1449296.91
E: 3113851.99
8" x 6" SWIVEL TEE
1 - 6" GV (W)
STA.=12+57.14
N: 1449196.54
E: 3113851.94
CONNECT TO EXISTING 8" WATER
30"x8" TAPPING SADDLE w/ 8" GV (N) & TB
STA.=14+60.34
N: 1448993.34
E: 3113851.83
CONNECT TO EXISTING 30" WATER
30"x8" TAPPING SADDLE w/ 8" GV (S) & TB
(PHASE 1)
STA.=10+00.00
N: 1448993.18
E: 3113684.25
22.5° BEND w/ TB
STA.=10+45.07
N: 1448948.07
E: 3113683.89
8" x 6" SWIVEL TEE
1 - 6" GV (NW)
STA.=10+53.12
N: 1448940.65
E: 3113680.64
45° BEND w/ TB
STA.=10+91.57
N: 1448905.44
E: 3113665.20
8" x 6" TEE w/ TB
1 - 6" GV (S)
STA.=16+22.28
N: 1449252.34
E: 3113620.75
8" x 6" TEE w/ TB
1 - 6" GV (S)
STA.=10+77.16
N: 1449296.95
E: 3113772.37
8" x 4" TEE w/ TB
1 - 4" GV (E)
STA.=11+93.58
N: 1449260.10
E: 3113851.97
8" x 4" TEE w/ TB
1 - 4" GV (E)
STA.=12+23.20
N: 1449230.48
E: 3113851.96
8" x 4" TEE w/ TB
1 - 4" GV (E)
STA.=12+66.75
N: 1449186.93
E: 3113851.94
8" x 4" TEE w/ TB
1 - 4" GV (E)
STA.=13+10.14
N: 1449143.54
E: 3113851.91
8" x 6" SWIVEL TEE
1 - 6" GV (E)
STA.=13+77.20
N: 1449076.48
E: 3113851.88
8" x 4" TEE w/ TB
1 - 4" GV (E)
STA.=14+12.83
N: 1449040.85
E: 3113851.86
PROPOSED 1'
SIDEWALK CHASE
PROPOSED 1'
SIDEWALK CHASE
PROPOSED 2'
SIDEWALK CHASE
PROPOSED 1'
SIDEWALK CHASE
PROPOSED 2'
SIDEWALK CHASE
PROPOSED 1'
SIDEWALK CHASE
PROPOSED 1'
SIDEWALK CHASE
PROPOSED 2'
SIDEWALK CHASE9' SIDEWALK9' SIDEWALK9' SIDEWALK9' SIDEWALK7' SIDEWALK6' SIDEWALK9' SIDEWALK
10' SIDEWALK WALLENBERG DR.6' SID
E
W
A
L
K
4' SIDEWALK
4' SIDEWALK4' SIDEWALKEXIST
ING
8
' TRAIL
TRACT A
CANAL
IMPORTAT
ION
CANAL IMPORTATIONLOT 1
LOT 1 10' SIDEWALK6' SIDEWALK
12' ACCESS TRAIL10' SIDEWALK4' SIDEWALKPROPOSED 2'
SIDEWALK CHASE
PROPOSED 2'
SIDEWALK CHASE
INLET 1-6.2-4
INV.=5010.60
FG=5013.01
BEND 1-6.2-3
INV.=5010.46
FG=5014.83
BEND 1-6.2-2
INV.=5010.39
FG=5014.85
BEND 1-6.2-1
INV.=5010.34
FG=5014.88
43.50 LF
8" HDPE
@ 0.40%
PROPOSED 1'
SIDEWALK CHASE
STORM DRAIN 2A
SEE SHEET C 623
41.87 LF 8" PVC
S00°26'56"W
4.86 LF 8" PVC
S23°40'29"W
38.44 LF 8" PVCS23°40'29"W44.69 LF 8" PVC
N00°01'50"E 77.11 LF 8" PVCN00°02'10"E77.71 LF 8" PVC
N00°01'30"E
156.78 LF 8" PVC
S89°58'10"E
100.37 LF 8" PVC
S00°01'50"W
203.20 LF 8" PVCS00°01'50"WPROPOSED
FIRE HYDRANT
CONNECT TO EXISTING 8" WATER
8"x6" TAPPING SADDLE w/ 6" GV (S) & TB
N:1449452.76
E:3113606.06
CONNECT TO EXISTING 8" WATER
8"x6" TAPPING SADDLE w/ 6" GV (S) & TB
N:1449440.78
E:3113695.29
WATER
LOWERING
WATER
LOWERING
17.51 LF 6" PVC
S00°01'50"W
11.31 LF 4" PVC
S44°39'07"E
45.00 LF 4" PVC
S89°39'07"E
103.45 LF 6" PVC
S89°39'07"E
9.91 LF 6" PVC
N42°49'06"E
54.49 LF 6" PVC
N90°00'00"E
13.94 LF 4" PVC
S00°20'53"W
13.78 LF 4" PVC
S00°20'53"W
18.66 LF 4" PVC
S00°20'53"W
45° BEND w/ TB
N:1449448.05
E:3113756.52
45° BEND w/ TB
N:1449440.78
E:3113749.79
8" x 6" TEE w/ TB
1 - 6" GV (E)
STA.=18+85.21
N: 1449440.78
E: 3113695.29
WATER
LOWERING
37.54 LF 4" PVC
S89°58'10"E
29.74 LF 4" PVC
S89°58'10"E
32.27 LF 4" PVC
S89°58'10"E
31.91 LF 4" PVC
S89°58'10"E
10.37 LF 4" PVC
S00°20'53"W
WATER
LOWERING
29.74 LF 4" PVC
S89°58'10"E
PROPOSED 2'
CONCRETE PAN 37.54 LF 4" PVC
S89°58'10"E
SEE NOTE #16
SEE NOTE #16
SEE NOTE #16
SEE NOTE #16
SEE NOTE #16
PIPE END C1
FG=5009.09
INLET C2
INV.=5009.33
FG=5012.20
11.82 LF
8" HDPE
@ 2.00%
EMERGENCY
OVERFLOW WEIR
NOTES:
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY
OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN
THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE
CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES
AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES.
2.ALL WATER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITIES
SPECIFICATIONS , LATEST EDITION, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS
ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR
AS REQUIRED FOR ABNORMAL DEFLECTIONS.
3.ALL SEWER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY
SPECIFICATIONS SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST
EDITION.
4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE
NOT TO SCALE.
5.ALL WATERLINES SHALL HAVE A 4.5'-5' COVER FROM FINISHED GRADE TO TOP OF PIPE.
6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS
SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND
ARE SUBJECT TO CHANGE IN THE FIELD.
7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
SANITARY SEWER MAINS, WATER MAINS & SERVICES.
8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN
THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO
BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS.
10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 1 4"
BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO
PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
11.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE CITYREGULATED, 100YEAR
CANAL IMPORTATION FLOODPLAIN/FLOODWAY AS WELL AS THE FEMA REGULATED
SPRING CREEK 100YEAR FLOODPLAIN/FLOODWAY. ANY DEVELOPMENT WITHIN THE
FLOODPLAIN MUST COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF CITY
MUNICIPAL CODE. THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM
THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE PERMIT FEES
PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES,
GRADING, FILL, DETENTION PONDS, BIKE PATHS, PARKING LOTS, UTILITIES,
LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE CITY OF FORT
COLLINS FLOODPLAIN LIMITS AS DELINEATED ON THE FINAL SUBDIVISION PLAT
12.ANY CONSTRUCTION ACTIVITIES, NONSTRUCTURAL DEVELOPMENT (BRIDGES,
SIDEWALKS, CULVERTS, VEGETATION, CURBCUTS, GRADING, ETC.) IN THE
REGULATORY FLOODWAY MUST BE PRECEDED BY A NORISE CERTIFICATION, WHICH
MUST BE PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF
COLORADO.
13.NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE FLOODWAY,
WHETHER TEMPORARY (DURING CONSTRUCTION) OR PERMANENT.
14. ANY PEDESTRIAN BRIDGES IN THE FLOODWAY THAT ARE NOT ABLE TO PASS THE 100
YEAR FLOW ARE REQUIRED TO BE “BREAKAWAY” AND TETHERED.
15. A BLANKET UTILITY EASEMENT EXISTS ACROSS THE PROJECT BOUNDARY WHERE
OTHER EASEMENTS ARE NOT PRESENT.
16. WATER AND FIRE SERVICES MUST HAVE A MINIMUM OF 4.5 FET OF COVER AND A
MINIMUM OF 18" VERTICAL CLEARANCE FROM STORM SEWERS. ANY STORM SEWER
SHALLOWER THAN 5.0 FET WILL REQUIRE THE WATER SERVICE TO BE INSTALLED
UNDER THE PROPOSED STORM SEWER.
EXISTING LOT LINE
EASEMENT LINE
SPROPOSED SEWER SERVICE
WPROPOSED WATER SERVICE
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
G
T
EXISTING STORM SEWER
EXISTING TELEPHONE
EXISTING GAS
EXISTING SANITARY SEWER
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPERTY BOUNDARY
EXISTING TELEPHONE PEDESTAL
PROPOSED STREET LIGHT
W
SS
PROPOSED LOT LINE
PROPOSED ROW
EXISTING ROW
EXISTING CABLE CTV
PROPOSED WATER MAIN (PHASE 1)
PROPOSED SANITARY SEWER (PHASE 1)
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 43
C 602UTILITY PLAN21
( IN FEET )
0
1 INCH = 30 FEET
30 30 60 90
NORTH
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
C
601
C
602
C
603
C
604
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
SEE SHEET C 604SEE SHEET C 601
CABLE
F.O.
VAULT
ELECVAULT
ELEC
T
E
T S
H2O
TRAFFIC
VAULTT SVAULT
ELEC
CONTROL
IRR
CONTROL
IRR
GGGGEEFOFOEEEEEEEEEEEEEEEEEEGGGGGGGGGGGGG30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W36" W36" W36" W36" W36" WD
F.O.
D
S
ELEC
/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /STSTSTSTSTSTSTSTSTSTSTSTSS SS STHILL POND CONDOMINIUMS
S
SSSSSSSSSSSSSSSSSSSSSSSSSSSSEXISTING 36" WATERLINE
E
E
E
E
E
E
E
E
E
G G G G G G G G G
G
G
G
G
G
G
G
G
G GF TSVAULT
ELEC
WW
UD
UD
UD
EEEEEEEEE E E E E E E E EE E E E
SSFDC
G G G G G G G G
PROPOSED 8"
PVC WATER
60'
FL-FL
PROPOSED 2'
CONCRETE CHASE
26' EMERGENCY
ACCESS
EASEMENT
EXISTING 26"
STORM DRAIN
EXISTING 30"
STORM DRAIN
PROPOSED
FIRE HYDRANT
PROPOSED 4'
SIDEWALK CULVERT
NATURAL AREA
BUFFER
EXISTING 30"
WATERLINE
FEMA 100-YR
HIGH RISK
FLOOD FRINGE
EXISTING 18" CLAY
SANITARY SEWER
PROPOSED
POND OUTLET
STRUCTURE
PROPOSED
STORM CHAMBERS 2
PROPOSED 2'
CONCRETE PAN
FEMA 100-YR
FLOODWAY
STORM DRAIN 4
SEE SHEET C 624
STORM DRAIN 5
SEE SHEET C 625
STORM DRAIN 6
SEE SHEET C 626
UTILIT
Y
E
A
S
E
M
E
N
T
EXCL
U
SI
O
N
BUILDING 1
22.5° BEND w/ TB
STA.=13+37.79
N: 1448815.90
E: 3113435.84
8" x 6" SWIVEL TEE
1 - 6" GV (S)
STA.=14+71.37
N: 1448815.97
E: 3113302.26
8" x 6" TEE w/ TB
1 - 6" GV (N)
STA.=15+30.23
N: 1448816.01
E: 3113243.40
6' SIDEWALK 6' SIDEWALK
10' SIDE
W
A
L
K
S SHIELDS ST.6' SID
E
W
A
L
K
EXIS
TI
N
G
S
P
RI
N
G
C
R
E
E
K
T
R
AI
L
SPRI
N
G
C
R
E
E
K
TRACT C
LOT 1
EXISTING SIDEWALKLOT 1
TRACT B
9' SIDEWALK
10' SIDEWALK
W STUART ST.38.44 LF 8" PVCS23°40'29"W246.22
L
F
8
"
P
V
C
S68°4
0'
2
9
"
W
133.58 LF 8" PVC
N89°58'10"W
196.76 LF 8" PVC
N89°58'10"W
34.85 LF 6" PVC
S00°00'00"E
NOTES:
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY
OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN
THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE
CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES
AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES.
2.ALL WATER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITIES
SPECIFICATIONS , LATEST EDITION, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS
ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR
AS REQUIRED FOR ABNORMAL DEFLECTIONS.
3.ALL SEWER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY
SPECIFICATIONS SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST
EDITION.
4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE
NOT TO SCALE.
5.ALL WATERLINES SHALL HAVE A 4.5'-5' COVER FROM FINISHED GRADE TO TOP OF PIPE.
6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS
SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND
ARE SUBJECT TO CHANGE IN THE FIELD.
7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
SANITARY SEWER MAINS, WATER MAINS & SERVICES.
8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN
THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO
BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS.
10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 1 4"
BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO
PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
11.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE CITYREGULATED, 100YEAR
CANAL IMPORTATION FLOODPLAIN/FLOODWAY AS WELL AS THE FEMA REGULATED
SPRING CREEK 100YEAR FLOODPLAIN/FLOODWAY. ANY DEVELOPMENT WITHIN THE
FLOODPLAIN MUST COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF CITY
MUNICIPAL CODE. THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM
THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE PERMIT FEES
PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES,
GRADING, FILL, DETENTION PONDS, BIKE PATHS, PARKING LOTS, UTILITIES,
LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE CITY OF FORT
COLLINS FLOODPLAIN LIMITS AS DELINEATED ON THE FINAL SUBDIVISION PLAT
12.ANY CONSTRUCTION ACTIVITIES, NONSTRUCTURAL DEVELOPMENT (BRIDGES,
SIDEWALKS, CULVERTS, VEGETATION, CURBCUTS, GRADING, ETC.) IN THE
REGULATORY FLOODWAY MUST BE PRECEDED BY A NORISE CERTIFICATION, WHICH
MUST BE PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF
COLORADO.
13.NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE FLOODWAY,
WHETHER TEMPORARY (DURING CONSTRUCTION) OR PERMANENT.
14. ANY PEDESTRIAN BRIDGES IN THE FLOODWAY THAT ARE NOT ABLE TO PASS THE 100
YEAR FLOW ARE REQUIRED TO BE “BREAKAWAY” AND TETHERED.
15. A BLANKET UTILITY EASEMENT EXISTS ACROSS THE PROJECT BOUNDARY WHERE
OTHER EASEMENTS ARE NOT PRESENT.
16. WATER AND FIRE SERVICES MUST HAVE A MINIMUM OF 4.5 FET OF COVER AND A
MINIMUM OF 18" VERTICAL CLEARANCE FROM STORM SEWERS. ANY STORM SEWER
SHALLOWER THAN 5.0 FET WILL REQUIRE THE WATER SERVICE TO BE INSTALLED
UNDER THE PROPOSED STORM SEWER.
EXISTING LOT LINE
EASEMENT LINE
SPROPOSED SEWER SERVICE
WPROPOSED WATER SERVICE
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
G
T
EXISTING STORM SEWER
EXISTING TELEPHONE
EXISTING GAS
EXISTING SANITARY SEWER
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPERTY BOUNDARY
EXISTING TELEPHONE PEDESTAL
PROPOSED STREET LIGHT
W
SS
PROPOSED LOT LINE
PROPOSED ROW
EXISTING ROW
EXISTING CABLE CTV
PROPOSED WATER MAIN (PHASE 1)
PROPOSED SANITARY SEWER (PHASE 1)
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 43
C 603UTILITY PLAN22
( IN FEET )
0
1 INCH = 30 FEET
30 30 60 90
NORTH
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
C 601 C 602
C 603 C 604
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
SEE SHEET C 601
SEE SHEET C 60450' PUBLIC ACCESS &
TRAIL EASEMENT
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBXUDUDUDUDUDUDUDUDELEC
XXXXXXXXXXXXXWINNE GRANT R/JOHNELLE S
1821 WALLENBERG DR
ERIKSEN CHRISTOPHER M
1825 WALLENBERG DR
MCCOY JOHN H/SHERRY P
1900 S SHIELDS ST
2
1
"
S
S
2
1
"
S
S
E
E
E
G
G
G GGEETEXISTING 6"
CMP STORM
DRAIN
EXISTING
UNDERDRAIN
26' EMERGENCY
ACCESS
EASEMENT
FEMA 100-YR
HIGH RISK
FLOOD FRINGE
CITY OF FORT
COLLINS 100-YR
FLOODPLAIN
NATURAL AREA
BUFFER
FEMA 100-YR
HIGH RISK
FLOOD FRINGE
PROPOSED 2'
CONCRETE PAN
PROPOSED
RETAINING WALL
(TYP.)
50' PUBLIC ACCESS &
TRAIL EASEMENT
FEMA 100-YR
FLOODWAY CITY OF FORT COLLINS
100-YR FLOODWAY
STORM DRAIN 5
SEE SHEET C 625
STORM DRAIN 5-2
SEE SHEET C 625
E: 3113683.89
10' SIDE
W
A
L
K
6' SID
E
W
A
L
K
SPRING CREEK
EXISTING
S
P
R
I
N
G
C
R
E
E
K
T
R
A
I
L
TRACT B CANAL IMPORTATIONLOT 1
TRACT A12' ACCESS TRAIL10' SIDEWALK38.44 LF 8" PVCS23°40'29"WEMERGENCY
OVERFLOW WEIR
PROPOSED
POND OUTLET
STRUCTURE
NOTES:
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY
OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN
THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE
CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES
AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES.
2.ALL WATER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITIES
SPECIFICATIONS , LATEST EDITION, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS
ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR
AS REQUIRED FOR ABNORMAL DEFLECTIONS.
3.ALL SEWER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY
SPECIFICATIONS SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST
EDITION.
4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE
NOT TO SCALE.
5.ALL WATERLINES SHALL HAVE A 4.5'-5' COVER FROM FINISHED GRADE TO TOP OF PIPE.
6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS
SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND
ARE SUBJECT TO CHANGE IN THE FIELD.
7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
SANITARY SEWER MAINS, WATER MAINS & SERVICES.
8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN
THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO
BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS.
10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 1 4"
BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO
PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
11.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE CITYREGULATED, 100YEAR
CANAL IMPORTATION FLOODPLAIN/FLOODWAY AS WELL AS THE FEMA REGULATED
SPRING CREEK 100YEAR FLOODPLAIN/FLOODWAY. ANY DEVELOPMENT WITHIN THE
FLOODPLAIN MUST COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF CITY
MUNICIPAL CODE. THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM
THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE PERMIT FEES
PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES,
GRADING, FILL, DETENTION PONDS, BIKE PATHS, PARKING LOTS, UTILITIES,
LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE CITY OF FORT
COLLINS FLOODPLAIN LIMITS AS DELINEATED ON THE FINAL SUBDIVISION PLAT
12.ANY CONSTRUCTION ACTIVITIES, NONSTRUCTURAL DEVELOPMENT (BRIDGES,
SIDEWALKS, CULVERTS, VEGETATION, CURBCUTS, GRADING, ETC.) IN THE
REGULATORY FLOODWAY MUST BE PRECEDED BY A NORISE CERTIFICATION, WHICH
MUST BE PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF
COLORADO.
13.NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE FLOODWAY,
WHETHER TEMPORARY (DURING CONSTRUCTION) OR PERMANENT.
14. ANY PEDESTRIAN BRIDGES IN THE FLOODWAY THAT ARE NOT ABLE TO PASS THE 100
YEAR FLOW ARE REQUIRED TO BE “BREAKAWAY” AND TETHERED.
15. A BLANKET UTILITY EASEMENT EXISTS ACROSS THE PROJECT BOUNDARY WHERE
OTHER EASEMENTS ARE NOT PRESENT.
16. WATER AND FIRE SERVICES MUST HAVE A MINIMUM OF 4.5 FET OF COVER AND A
MINIMUM OF 18" VERTICAL CLEARANCE FROM STORM SEWERS. ANY STORM SEWER
SHALLOWER THAN 5.0 FET WILL REQUIRE THE WATER SERVICE TO BE INSTALLED
UNDER THE PROPOSED STORM SEWER.
EXISTING LOT LINE
EASEMENT LINE
SPROPOSED SEWER SERVICE
WPROPOSED WATER SERVICE
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
G
T
EXISTING STORM SEWER
EXISTING TELEPHONE
EXISTING GAS
EXISTING SANITARY SEWER
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPERTY BOUNDARY
EXISTING TELEPHONE PEDESTAL
PROPOSED STREET LIGHT
W
SS
PROPOSED LOT LINE
PROPOSED ROW
EXISTING ROW
EXISTING CABLE CTV
PROPOSED WATER MAIN (PHASE 1)
PROPOSED SANITARY SEWER (PHASE 1)
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 43
C 604UTILITY PLAN23
( IN FEET )
0
1 INCH = 30 FEET
30 30 60 90
NORTH
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
C 601 C 602
C 603 C 604
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
SEE SHEET C 602
SEE SHEET C 603
SSST SH2OTRAFFICVAULTT SVAULTELECSVAULTELECVAULTELECCONTROLIRRCONTROLIRRCONTROLIRRELECCONTROLIRRCONTROLIRRCONTROLIRRCONTROLIRRCONTROLIRRSCONTROLIRRCONTROLIRRCONTROLIRRCONTROLIRRS15" SS 18" SS18" SS18" SS18" SS18" SS18" SS21" SS21" SS 21" SS21" SS21" SS21" SS21" SS8" SSEEEEEEEEEEEETTTTTTTTTTGGGGGGGGGGGGGWWWWWWWW12" W12" W12" W12" W12" W12" W12" WEEEEEEEG30" W30" W36" W 36" W
36" WD/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /30" W30" W30" W30" W30" W30" WSSSSSSSSWWFF
FEGGGGGGFTT
GTTSEVAULTELECVAULTELECEEEEEEWWEEEEEEEEGGGGGGSSEFDCFDCFDCFDCIRWG G
GGGGG G G G GGGS SHIELDS STREET
SSMH A1
STA 10+00.00
N: 1449316.39
E: 3113247.23
166.84 LF 8" PVC @ 0.50%
SSMH A3
STA 11+94.79
N: 1449121.61
E: 3113247.13
158.39 LF 8" PVC @ 0.50%
SSMH A4
STA 13+53.18
N: 1448963.21
E: 3113247.04
EXISTING 12"
WATERHOBBIT STREETPROPOSED
FIRE HYDRANT
EXISTING 18"
SANITARY SEWER
EXISTING 21"
SANITARY SEWER
EXISTING 8"
WATER LINE
EXISTING 30"
WATER LINE
PROPOSED
FIRE HYDRANT
CONNECT TO
EXISTING SANITARY
SEWER LINE w/
PRECAST MH 6' SIDEWALK6' SIDEWALK6' SIDEWALK9' SIDEWALK6' SIDEWALK9' SIDEWALKPROPOSED 4'
CONCRETE PAN
PROPOSED 4'
CONCRETE PAN
PROPOSED 8"
PVC WATER
PROPOSED 4'
SIDEWALK CULVERT
SANITARY LINE A2
SEE THIS SHEET - RIGHT
STORM DRAIN 4
SEE SHEET C 624
STORM DRAIN 4-4B
SEE SHEET C 624
STORM DRAIN 1
SEE SHEET C 620
STORM DRAIN 4-4A
SEE SHEET C 624
PROPOSED
FIRE HYDRANT
PROPOSED
FIRE HYDRANT
STORM DRAIN 6
SEE SHEET C 626
49.21 LF 8" PVC @ 0.50%
SSMH A8
STA 14+96.22
N: 1448962.60
E: 3113390.08
BUILDING
6
BUILDING
7
BUILDING
3
BUILDING
2
27.95 LF 8" PVC @ 0.50%
81.83 LF 8" PVC @ 0.50%
6.00 LF 8" PVC @ 0.50%
6.00 LF 8" PVC @ 0.50%
SSERV A2
STA 11+66.84
N: 1449149.55
E: 3113247.14
BLDG 2 SSERV
INV. OUT=5009.66 (E)
32.06 LF 6" @ 2.00%
SSERV A5
STA 14+02.39
N: 1448962.99
E: 3113296.25
32.45 LF 6" PVC @ 2.00%
BLDG 1 SSERV 1
INV. OUT=5011.06 (N)
SSERV A6
STA 14+84.22
N: 1448962.63
E: 3113378.08
32.13 LF 6" PVC @ 2.00%
BLDG 1 SSERV 2
INV. OUT=5011.47 (N)
BLDG 1 SSERV 3
INV. OUT=5011.76 (NW)
45.23 LF 8" PVC @ 2.00%
SSERV A7
STA 11+36.95
N: 1448962.60
E: 3113384.08
BLDG 6 SSERV
INV. OUT=5012.85 (S)
35.95 LF
6" PVC
@ 2.00%
BUILDING
1
4995
5000
5005
5010
5015
5020
5025
5030
5035
4995
5000
5005
5010
5015
5020
5025
5030
5035
9+50 10+00 11+00 12+00 13+00 14+00 15+00 15+50SSMH A1STA 10+00.00RIM 5020.0±INV. IN 5006.52 (W)INV. IN 5008.01 (S)INV. IN 5012.13 (N)INV. OUT 5006.51 (E)SSMH A3STA 11+94.79RIM 5016.6±INV. IN 5009.19 (S)INV. IN 5009.19 (E)INV. OUT 5008.99 (N)158.39 LF 8" PVC @ 0.50%SSMH A4STA 13+53.18RIM 5016.7±INV. IN 5010.17 (E)INV. OUT 5009.97 (N)PROPOSED
GROUND
EXISTING
GROUND
18" MIN.SSMH A8STA 11+42.95RIM 5016.3±INV. OUT 5010.88 (W)SERVICE A2STA 10+00.01RIM 5009.6±INV. IN 5009.02 (W)INV. IN 5008.85 (S)INV. OUT 5008.85 (N)SVC.SSERV A5STA 10+49.12INV. 5010.41 (S)INV. 5010.41 (E)INV. 5010.41 (W)SSERV A6STA 11+30.95INV. 5010.82 (E)INV. 5010.82 (S)INV. 5010.82 (W)SSERV A7STA 11+36.95INV. 5010.85 (E)INV. 5010.85 (SE)INV. 5010.85 (W)166.84 LF 8" PVC @ 0.50%
27.95 LF 8" PVC @ 0.50%
49.21 LF 8" PVC @ 0.50%
81.83 LF
8" PVC
@ 0.50%
6.00 LF
8" PVC
@ 0.50%
12" HDPE STORM
STA.=13+41.80
INV.=5013.41
6" PVC WATER
STA.=13+00.02
TOP=5012.20
30" WATER
STA.=13+22.58
TOP=5007.49
6.00 LF
8" PVC
@ 0.50%
S
S
VAULT
ELEC
VAULT
ELEC
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
ELEC
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
S
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS21" SS21" SS 21" SS 21" SS 21" SS 21" SS 21" SS
EEEEEEEEEETTTTTTTTGGGGGGGGG12" W12" W12" W12" W12" W12" W/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" WSSSSSWFFFTG
TT
EE
VAULT
ELEC
EEEE E E
WEEEE E
EFDC
FDC FDCFDC
IRW GGGGGGGGGGGGGTE6' SIDEWALK6' SIDEWALK6' SIDEWALK
9' SIDEWALK
SSMH A3
STA 10+00.00
N: 1449121.61
E: 3113247.13
125.17 LF 8" PVC @ 0.50%
SSMH A2-2
STA 11+92.91
N: 1449121.61
E: 3113440.04SANITARY LINE A
SEE THIS SHEET - LEFT
STORM DRAIN 4-4B
SEE SHEET C 624
STORM DRAIN 4-4A
SEE SHEET C 624
STORM DRAIN 1-6
SEE SHEET C 622
STORM DRAIN 1-7
SEE SHEET C 622
PROPOSED 4'
CONCRETE PAN
EXISTING 18"
SANITARY SEWER
STORM DRAIN 1
SEE SHEET C 620
PROPOSED
ELECTRIC
EXISTING 21"
SANITARY SEWER
PROPOSED
FIRE HYDRANT
PROPOSED
FIRE HYDRANT
PROPOSED
FIRE HYDRANT
EXISTING 30"
WATER LINE
PROPOSED
GAS
BUILDING
6
BUILDING
2
BUILDING
3
BUILDING
7
BUILDING
4
67.74 LF 8" PVC @ 0.50%
SSERV A2-1
STA 11+25.17
N: 1449121.61
E: 3113372.30
BLDG 3 SSERV
INV. OUT=5010.48 (N)
33.23 LF 6" PVC @ 2.00%
BLDG 4 SSERV
INV. OUT=5011.10 (W)
37.60 LF 6" @ 2.00%
4995
5000
5005
5010
5015
5020
5025
5030
5035
4995
5000
5005
5010
5015
5020
5025
5030
5035
9+50 10+00 11+00 12+00 12+50SSMH A3STA 10+00.00RIM 5016.6±INV. IN 5009.19 (S)INV. IN 5009.19 (E)INV. OUT 5008.99 (N)125.17 LF 8" PVC @ 0.50%SSMH A2-2STA 11+92.91RIM 5015.5±INV. IN 5010.35 (E)INV. OUT 5010.15 (W)PROPOSED
GROUND
EXISTING
GROUND
67.74 LF 8" PVC @ 0.50%SSERV A2-1STA 11+25.17INV. 5009.81 (E)INV. 5009.81 (S)INV. 5009.81 (W)SVC.8" PVC WATER
STA.=10+10.00
TOP=5011.91
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 43
C 610PLAN & PROFILESANITARY SEWER LINES A & A324
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
( IN FEET )
1 inch = ft.
Feet05050
50
100 150
PROFILE SCALE:
SANITARY LINE A
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
NOTES:
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.ALL SANITARY CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS WATER AND
WASTEWATER DESIGN CRITERIA.
3.MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF
NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED
WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS
SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND
ARE SUBJECT TO CHANGE IN THE FIELD.
5.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
STROM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES.
6.ALL SINGLE-FAMILY SANITARY SEWER SERVICES TO BE 4" PVC.
7.ALL SANITARY MANHOLES TO BE 4'Ø UNLESS NOTED OTHERWISE.
8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
W
EXISTING STORM SEWER
SPROPOSED SEWER SERVICE
EXISTING SANITARY SEWER SS
PROPOSED AREA STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPOSED LOT LINE
PROJECT BOUNDARY
EXISTING RIGHT OF WAY
W
EASEMENT LINE
PROPOSED RIGHT OF WAY
PROPOSED COMBO STORM INLET
PROPOSED TYPE-R STORM INLET
PROPOSED WATER SERVICE
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
NORTH
PROFILE SCALE:
SANITARY LINE A3
SANITARY
LINE A
SANITARY
LINE A2
NORTH
V.P.VAULTELECSSS18" SS18" SS18" SS18" SS18" SS18" SS18" SS18" SS21" SS21" SS21" SS21" SS21" SS21" SS21" SS8" SS8" SS8" SSWWWFDCFS EEEUDUD
UDUDUDUDUD
UD
UD UDUDUDUDUDSSSSWWWSHYDPROPOSED 4'
PROPOSED
FIRE HYDRANT
S SSSSWWFFF EEEEE
T
T
GEETSWWW
WFSVAULTELECVAULTELECEEEEEWWGGG G G G
EEEE18" SSWEEEEWGGGW
EEEEEEFDCFDCFDCFDCGFFFSSFSF
F
SF WF
GG
GGGGGG G TPROPOSED 8"
PVC WATER
SANITARY LINE C
SEE SHEET C 612
SANITARY LINE A2
SEE SHEET C 610
STORM DRAIN 1
SEE SHEET C 620
27.44 LF
8" PVC
@ 5.84%
EXMH B4
STA 11+59.90
N: 1449489.95
E: 3113685.33
STORM LINE 1
SEE SHEET C 620
STORM DRAIN 1-8
SEE SHEET C 622
STORM DRAIN 1-9
SEE SHEET C 622
EXISTING 8"
SANITARY SEWER
EXISTING 8"
WATER LINE
EXISTING
UNDERDRAIN
EXISTING 18"
SANITARY SEWER
EXISTING 21"
SANITARY SEWER
PROPOSED
FIRE HYDRANT PROPOSED 4'
CONCRETE PAN
PROPOSED
FIRE HYDRANT
NEW MH CONNECTIONS TO
EXISTING SANITARY SHALL
BE MADE w/ PRECAST MH
CONNECT TO
EXISTING MH
RESHAPE BASE
INSTALL NEW
PRECAST MANHOLE
CONNECT TO
EXISTING SANITARY
SANITARY LINE B1
SEE THIS SHEET-RIGHT
SSMH B3
STA 11+32.47
N: 1449462.51
E: 3113685.31
SANITARY LINE D
SEE SHEET C 612
SSMH B1
STA 10+00.00
N: 1449330.04
E: 3113685.24
EXISTING 244.98 LF @ 0.58%
67.36 LF
8" PVC
@ 0.50%
STORM LINE 1-5
SEE SHEET C 621
STORM LINE 1-6
SEE SHEET C 621
65.11 LF
8" PVC
@ 0.50%
63.96 LF
4" PVC
@ 2.00%
SSERV B2
STA 10+65.11
N: 1449395.15
E: 3113685.27
BLDG 18 SSERV
INV. OUT=5003.82 (W)
BUILDING 7
BUILDING 4
BUILDING 5
BUILDING 8
BUILDING 18
BUILDING 17
BUILDING 16BUILDING 1527.44 LF
8" PVC
@ 5.84%
4990
4995
5000
5005
5010
5015
5020
5025
5030
4990
4995
5000
5005
5010
5015
5020
5025
5030
9+5010+0011+0012+00
PROPOSED
GROUND
8" PVC WATER
STA.=11+21.69
TOP=5008.29
EXISTING
GROUND
67.36 LF 8" PVC @ 0.50%SSMH B1STA 10+00.00RIM 5014.1±INV. IN 5002.22 (N)INV. IN 5000.99 (E)INV. OUT 5000.99 (W)EXMH B4STA 11+59.90RIM 5012.5±INV. IN 5004.99 (N)INV. OUT 5004.79 (S)SSMH B3STA 11+32.47RIM 5012.8±INV. IN 5003.19 (N)INV. IN 5003.19 (W)INV. OUT 5002.88 (S)65.11 LF 8" PVC @ 0.50%SSERV B2STA 10+65.11INV. 5002.55 (N)INV. 5002.54 (E)INV. 5002.55 (S)27.44 LF
8" PVC
@ 5.84%
V.P.
VAULT
ELEC
S
S
S
18" SS 18" SS 18" SS 18" SS 18" SS 18" SS
21" SS 21" SS 21" SS 21" SS
8" SS 8" SS 8" SSW WW / / / / / / / // / / / / / / /FDC
FS
E E
UDU
D
U
D
UDUDUDUD
UD UDSSSSSSSS
W W W
S
HY DSSWWFETG
E E
TW
FVAULT
ELEC
EEEWG
E E E
E E E E
G G G
EEE
FDCFDCG FGG126.55 LF 8" PVC @ 0.50%
SSMH B3-1
STA 11+26.55
N: 1449464.13
E: 3113558.77
EXISTING 8"
SANITARY SEWER
EXISTING 8"
WATER LINE
EXISTING
UNDERDRAIN
EXISTING 21"
SANITARY SEWER
PROPOSED
FIRE HYDRANT
PROPOSED 4'
CONCRETE PAN
CONNECT TO
EXISTING MH
CONNECT TO
EXISTING MH
EXISTING 18"
SANITARY SEWERPROPOSED 8"
PVC WATER
STORM LINE 1-9
SEE SHEET C 622
STORM LINE 1
SEE SHEET C 620
SANITARY LINE B
SEE THIS SHEET-LEFT
SSMH B3
STA 10+00.00
N: 1449462.51
E: 3113685.31
BUILDING 7
BUILDING 18
BUILDING 8
149.55 LF 8" PVC @ 1.60%
INSTALL NEW
PRECAST MANHOLE
CONNECT TO
EXISTING SANITARY
4990
4995
5000
5005
5010
5015
5020
5025
5030
4990
4995
5000
5005
5010
5015
5020
5025
5030
9+5010+0011+0012+00 SSMH B3STA 10+00.00RIM 5012.8±INV. IN 5003.19 (N)INV. IN 5003.19 (W)INV. OUT 5002.88 (S)SSMH B3-1STA 11+26.55RIM 5014.0±EX. INV. IN 5003.90 (N)EX. INV. IN 5003.97 (W)PROP. INV. OUT 5003.82 (E)126.55 LF 8" PVC @ 0.50%
EXISTING
GROUND
2" HDPE WATER
STA.=10+05.91
INV.=5008.05
2" HDPE WATER
STA.=10+09.52
INV.=5008.00EX. INV. OUT 5003.76 (S, TOBE ABANDONED)SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 43
C 611PLAN & PROFILESANITARY SEWER LINES B & B325CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
( IN FEET )
1 inch = ft.
Feet05050
50
100 150
PROFILE SCALE:
SANITARY LINE B
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
NOTES:
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.ALL SANITARY CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS WATER AND
WASTEWATER DESIGN CRITERIA.
3.MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF
NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED
WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS
SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND
ARE SUBJECT TO CHANGE IN THE FIELD.
5.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
STROM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES.
6.ALL SINGLE-FAMILY SANITARY SEWER SERVICES TO BE 4" PVC.
7.ALL SANITARY MANHOLES TO BE 4'Ø UNLESS NOTED OTHERWISE.
8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
W
EXISTING STORM SEWER
SPROPOSED SEWER SERVICE
EXISTING SANITARY SEWER SS
PROPOSED AREA STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPOSED LOT LINE
PROJECT BOUNDARY
EXISTING RIGHT OF WAY
W
EASEMENT LINE
PROPOSED RIGHT OF WAY
PROPOSED COMBO STORM INLET
PROPOSED TYPE-R STORM INLET
PROPOSED WATER SERVICE
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
NORTH
SANITARY LINE B3
PROFILE SCALE:
NORTH
SANITARY
LINE B
SANITARY
LINE B1
S SSWWFFEEGGGEEEET
T
GEETSWWW
WW
FSSVAULTELECEEUD
UD
UD
WUDGGEEEGGGEEEGGG G G G G
W
EEE18" SSWEWW S TEEETEEE
FDCFDCFDCGFFFFGGS SSFSF
F F
SF WF
GG
GGGB
B
B
B
B
B
B
B
B
B
B
BBB
B
B
BB
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
BBB
B
B
BB
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
BB BBB
B
B
B
BBB
B
B
B
BB B
B
B
B BB
BB
B
B
B
BB
B
BB
B
B
B BB
B BB
B
B
B
B
B BB
B BB
XXX BBBBB
B
B
B
B
X
X
X
X
SS18" SS18" SS18" SS18" SS18" SS18" SS18" SS18" SS21" SS21" SS21" SS21" SS21" SS21" SS21" SSUDSUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMHHYDMM30" W30" W30" W30" W30" W30" W30" W30" WX
X
X
X
SSMH C1
STA 10+65.27
N: 1449313.92
E: 3113839.00
SSMH C8
STA 12+55.87
N: 1449123.32
E: 3113838.90
PROPOSED 8"
PVC WATER
SANITARY LINE D
SEE THIS SHEET - RIGHT
EXISTING 18"
SANITARY SEWER
PROPOSED
FIRE HYDRANT PROPOSED
FIRE HYDRANT
PROPOSED
RAIN GARDEN
PROPOSED 2'
CONCRETE PAN
CANAL I
M
P
O
R
T
A
T
I
O
N
EXISTING SANITARY
SEWER MANHOLE
PROPOSED 2'
CONCRETE PAN
EXISTING 30"
WATER LINE
NEW MH CONNECTIONS TO
EXISTING SANITARY SHALL
BE MADE W/ PRECAST MH
SANITARY LINE B
SEE SHEET C 611
STORM DRAIN 5
SEE SHEET C 625
EXISTING 21"
SANITARY SEWER
UNDERDRAIN
SEE SHEET C 626
STORM DRAIN 3
SEE SHEET C 623
STORM DRAIN 2
SEE SHEET C 623
BLDG 8
BLDG
4
BLDG 17
BLDG 18
BLDG 16
BLDG 15
BLDG 13 BLDG 12 BLDG 11
BLDG 10 BLDG 9
STORM DRAIN 1-5
SEE SHEET C 621
STORM DRAIN 1-6
SEE SHEET C 621
38.81 LF
8" PVC
@ 0.50%
BLDG 14
BLDG 9 SSERV
INV. OUT=5008.53 (W)
49.42 LF
4" PVC
@ 2.00%
SS BEND w CO C8-2
INV. IN=5007.54 (E)
INV. OUT=5007.54 (N)
52.07 LF
4" PVC
@ 2.00%
SS BEND w CO C8-1
INV. IN=5006.50 (S)
INV. OUT=5006.50 (N)
12.71 LF
4" PVC
@ 2.00%
7.22 LF
8" PVC
@ 0.50%
34.93 LF
4" PVC
@ 2.00%
SS BEND w CO C7-1
INV. IN=5006.58 (SE)
INV. OUT=5006.58 (W)
32.16 LF
4" PVC
@ 2.00%
BLDG 10 SSERV
INV. OUT=5007.22 (NW)
SSMH C
STA 9+99.96
N: 1449313.73
E: 3113904.31
32.17 LF
4" PVC
@ 9.00%
40.13 LF
4" PVC
@ 9.00%
BLDG 15 SSERV
INV. OUT=5007.64 (S)
BLDG 16 SSERV
INV. OUT=5008.35 (SE)
65.30 LF
18" PVC
@ 0.18%
43.48 LF
4" PVC
@ 8.50%
BLDG 17 SSERV
INV. OUT=5008.66 (SE)
SSERV C2
STA 11+04.08
N: 1449275.11
E: 3113838.98
54.62 LF
8" PVC
@ 0.50%
42.74 LF
4" PVC
@ 2.00%
BLDG 14 SSERV
INV. OUT=5006.01 (W)
SSERV C3
STA 11+58.71
N: 1449220.49
E: 3113838.95
43.55 LF
8" PVC
@ 0.50%
42.74 LF
4" PVC
@ 2.00%
BLDG 13 SSERV
INV. OUT=5006.28 (W)
SSERV C4
STA 12+02.26
N: 1449176.94
E: 3113838.93
45.09 LF
4" PVC
@ 2.00%
35.39 LF
8" PVC
@ 0.50%
SSERV C7
STA 12+48.65
N: 1449130.54
E: 3113838.91
SSERV C6
STA 12+43.65
N: 1449135.54
E: 3113838.91
44.91 LF
4" PVC
@ 2.00%
BLDG 11 SSERV
INV. OUT=5006.75 (W)
BLDG 12 SSERV
INV. OUT=5006.55 (W)
SSERV C5
STA 12+37.65
N: 1449141.54
E: 3113838.91
26.76 LF
6" PVC
@ 2.00%
5.00 LF
8" PVC
@ 0.50%
6.00 LF
8" PVC
@ 0.50%
BLDG 8 SSERV
INV. OUT=5006.36 (E)
4990
4995
5000
5005
5010
5015
5020
5025
5030
4990
4995
5000
5005
5010
5015
5020
5025
5030
10+0010+00 11+00 12+00 13+00 13+50SSMH C1STA 10+65.27RIM 5013.3±INV. IN 5003.46 (W)INV. IN 5004.96 (S)INV. IN 5004.96 (NW)INV. OUT 5003.36 (E)38.81 LF
8" PVC
@ 0.50%SSMH C8STA 12+55.87RIM 5013.1±INV. IN 5006.25 (S)INV. OUT 5005.91 (N)8" PVC WATER
STA.=13+30.66
TOP=5008.6124" RCP STORM
STA.=10+93.53
INV.=5009.11
PROPOSED
GROUND
EXISTING
GROUND
8" PVC WATER
STA.=10+82.28
TOP=5008.70 SSERV C2STA 11+04.08INV. 5005.16 (S)INV. 5005.16 (E)INV. 5005.16 (N)SSERV C3STA 11+58.71INV. 5005.43 (S)INV. 5005.43 (E)INV. 5005.43 (N)SSERV C4STA 12+02.26INV. 5005.65 (S)INV. 5005.65 (E)INV. 5005.65 (N)SSERV C5STA 12+37.65INV. 5005.82 (S)INV. 5005.82 (W)INV. 5005.82 (N)SSERV C6STA 12+43.65INV. 5005.85 (S)INV. 5005.85 (E)INV. 5005.85 (N)SSERV C7STA 12+48.65INV. 5005.88 (S)INV. 5005.88 (E)INV. 5005.88 (N)6" PVC WATER
STA.=11+82.65
TOP=5008.86
54.62 LF
8" PVC
@ 0.50%
43.55 LF
8" PVC
@ 0.50%
35.39 LF
8" PVC
@ 0.50%
6.00 LF
8" PVC
@ 0.50%
7.22 LF
8" PVC
@ 0.50%
5.00 LF
8" PVC
@ 0.50%
S SSWWFFEEGGGEEEET
T
GEETTSWWW
EWW
FSSVAULTELECEEUD
WWUDGGEEEGGGEEEEEEGGG G G G GW
EEEE18" SSWEEEWGW S TEEETEEE
FDCFDCFDCGFFFFGGS SSFSF
F F
SF WF
GG
GGGGGGGB
B
B
B
BBBB
B
B
BB
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
BBB
B
B
BB
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B BBB
B
B
B
BB
B
B
B
B
B
B
B
B
B BBBBB
B
B
B
BBB
B
B
B
B BBB
B BB
B
B
B
B
B BB
B BB
XXX
SSS18" SS18" SS18" SS18" SS18" SS18" SS18" SS21" SS21" SS21" SS21" SS21" SS21" SSUDUD UDUDUDUDUDUDUDWWWSUDUDHYDMH30" W30" W30" W30" W30" W30" W30" W30" WPROPOSED 8"
PVC WATER
EXISTING 21"
SANITARY SEWER
PROPOSED
FIRE HYDRANT PROPOSED
FIRE HYDRANT
PROPOSED 2'
CONCRETE PAN
PROPOSED 4'
CONCRETE PAN
EXISTING SANITARY
SEWER MANHOLE
PROPOSED 2'
CONCRETE PAN
EXISTING 30"
WATER LINE
STORM DRAIN 1
SEE SHEET C 620
SANITARY LINE B
SEE SHEET C 611
EXISTING 21"
SANITARY SEWER
183.88 LF 8" PVC @ 2.00%
SSMH D3
STA 11+90.27
N: 1449124.21
E: 3113685.13
SSMH D1
STA 10+00.00
N: 1449314.48
E: 3113685.23
BLDG 17
BLDG 18
BLDG 16
BLDG 15
BLDG
4
BLDG
7
BLDG 13 BLDG 12 BLDG 11
BLDG 10 BLDG 9
BLDG 14
BLDG 8
BLDG
5
6.39 LF 8" PVC @ 2.00%
SSERV D2
STA 11+83.88
N: 1449130.60
E: 3113685.13
35.88 LF 6" PVC @ 2.00%
BLDG 5 SSERV
INV. OUT=5010.12 (NE)
NEW MH CONNECTIONS TO
EXISTING SANITARY SHALL
BE MADE W/ PRECAST MH
STORM DRAIN 1-5
SEE SHEET C 621
STORM DRAIN 1-8
SEE SHEET C 620
SANITARY LINE C
SEE THIS SHEET - LEFT
4990
4995
5000
5005
5010
5015
5020
5025
5030
4990
4995
5000
5005
5010
5015
5020
5025
5030
9+50 10+00 11+00 12+00 12+50SSMH D1STA 10+00.00RIM 5014.0±INV. IN 5005.72 (S)INV. IN 5004.22 (W)INV. OUT 5004.22 (E)183.88 LF
8
"
P
V
C
@
2
.
0
0
%SSMH D3STA 11+90.27RIM 5015.0±INV. OUT 5009.53 (N)PROPOSED
GROUND
EXISTING
GROUND
8" PVC WATER
STA.=10+62.18
TOP=5010.26
24" RCP STORM
STA.=10+35.75
INV.=5009.53
6.39 LF
8" PVC
@ 2.00%SSERV D2STA 11+83.88INV. 5009.40 (S)INV. 5009.40 (SW)INV. 5009.40 (N)SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 43
C 612PLAN & PROFILESANITARY SEWER LINES C & D26CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
( IN FEET )
1 inch = ft.
Feet05050
50
100 150
PROFILE SCALE:
SANITARY LINE C
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
NOTES:
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.ALL SANITARY CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS WATER AND
WASTEWATER DESIGN CRITERIA.
3.MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF
NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED
WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS
SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND
ARE SUBJECT TO CHANGE IN THE FIELD.
5.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
STROM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES.
6.ALL SINGLE-FAMILY SANITARY SEWER SERVICES TO BE 4" PVC.
7.ALL SANITARY MANHOLES TO BE 4'Ø UNLESS NOTED OTHERWISE.
8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
W
EXISTING STORM SEWER
SPROPOSED SEWER SERVICE
EXISTING SANITARY SEWER SS
PROPOSED AREA STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPOSED LOT LINE
PROJECT BOUNDARY
EXISTING RIGHT OF WAY
W
EASEMENT LINE
PROPOSED RIGHT OF WAY
PROPOSED COMBO STORM INLET
PROPOSED TYPE-R STORM INLET
PROPOSED WATER SERVICE
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
SANITARY
LINES
C & D
SANITARY LINE D
PROFILE SCALE:
SSSSSS
SSWWWFF
FFFEEEEETTGTE E
TTG
S
WWWW
WFSS
E
VAULT
ELEC
VAULT
ELEC
EEEE E E EEUDUDUDWWG G
GGGGGW
E E E E
EEEE18" SS
WE E E E
W
G G G G G G G G
WSEE EEE E
FDC FDCFDCFDC FDC
FDCG FFFFGG
SSSFSFFSFWFGGGGGGGGGGGGGGGTXXXXXXXXXXINLET 1-14
STA 19+28.91
N: 1449427.58
E: 3113371.58
STMH 1-9
STA 16+77.43
N: 1449263.33
E: 3113468.37
STMH 1-7
STA 15+40.54
N: 1449263.59
E: 3113605.26
STMH 1-5
STA 14+21.50
N: 1449285.73
E: 3113722.21
INLET 1-3
STA 11+12.59
N: 1449118.06
E: 3113863.44
INLET 1-4
STA 12+80.19
N: 1449285.65
E: 3113863.53
BEND 1-13
STA 19+09.45
N: 1449411.75
E: 3113360.26
TEE 1-12
STA 18+77.04
N: 1449379.34
E: 3113360.25
BEND 1-11
STA 18+39.01
N: 1449341.31
E: 3113360.23
BEND 1-10
STA 17+60.97
N: 1449341.27
E: 3113438.27
TEE 1-8
STA 15+79.71
N: 1449263.61
E: 3113566.09
FES 1-1
STA 10+00.00
N: 1449118.00
E: 3113976.04
99.98 LF 30" RCP @ 0.20%167.59 LF 30" RCP @ 0.20%141.32 LF 24" RCP @ 0.20%
105.46 LF 24" RCP @ 0.50%
39.17 LF 24" RCP @ 0.50%
97.72 LF 24" RCP @ 0.50%
83.54 LF 8" HDPE @ 0.50%
78.04 LF 8" HDPE @ 0.50%
38.03 LF 8" HDPE @ 0.50%
32.41 LF 8" HDPE @ 0.50%
19.46 LF 8" HDPE @ 0.50%
HOBBIT STREET
LANDMARK
APARTMENTS
EXISTING 18"
SANITARY SEWER
EXISTING 21"
SANITARY SEWER
EXISTING 8" PVC
WATER
PROPOSED FH
PROPOSED FH
PROPOSED FH
PROPOSED FH
PROPOSED
RAIN GARDEN
SANITARY LINE A
SEE SHEET C 610
SANITARY LINE D
SEE SHEET C 612
SANITARY LINE C
SEE SHEET C 612
PROPOSED
GAS PROPOSED
ELECTRIC
SANITARY LINE B
SEE SHEET C 611
SANITARY LINE B1
SEE SHEET C 611
UNDERDRAIN
SEE SHEET C 626
STORM DRAIN 1-9
SEE SHEET C 622
STORM DRAIN 1-8
SEE SHEET C 622
BUILDING 6 BUILDING 7
BUILDING 2
BUILDING 3
BUILDING 4 BUILDING 5 BUILDING 8
BUILDING 18 BUILDING 17
BUILDING 16 BUILDING 15
BUILDING 14
BUILDING 13
BUILDING 12
BUILDING 11
BUILDING 10
BUILDING 9
TEE 1-6
STA 14+35.08
N: 1449283.20
E: 3113708.87
4995
5000
5005
5010
5015
5020
5025
5030
4995
5000
5005
5010
5015
5020
5025
5030
9+5010+0011+0012+0013+0014+0015+0016+0017+0018+0019+0020+0020+50 INLET 1-14STA 19+28.91RIM 5015.7±INV. OUT 5013.32 (SW)19.46 LF
8" HDPE
@ 0.50%
32.41 LF
8" HDPE
@ 0.50%
38.03 LF
8" HDPE
@ 0.50%BEND 1-11STA 18+39.01RIM 5013.6±INV. IN 5012.87 (N)INV. OUT 5012.87 (E)78.04 LF
8" HDPE
@ 0.50%BEND 1-10STA 17+60.97RIM 5013.3±INV. IN 5012.48 (W)INV. OUT 5012.48 (S)83.54 LF
8" HDPE
@ 0.50%STMH 1-9STA 16+77.43RIM 5015.5±INV. IN 5012.06 (N)INV. IN 5010.63 (S)INV. OUT 5010.63 (E)97.72 LF 24" RCP @ 0.50%TEE 1-8STA 15+79.71RIM 5012.5±INV. IN 5010.14 (W)INV. IN 5010.81 (S)INV. OUT 5010.14 (E)39.17 LF
24" RCP
@ 0.50%STMH 1-7STA 15+40.54RIM 5015.3±INV. IN 5009.94 (W)INV. OUT 5009.94 (E)105.46 LF
24" RCP
@ 0.50%STMH 1-5STA 14+21.50RIM 5014.2±INV. IN 5009.34 (W)INV. IN 5009.34 (S)INV. OUT 5009.34 (E)141.32 LF 24" RCP @ 0.20%INLET 1-4STA 12+80.19RIM 5012.9±INV. IN 5009.06 (W)INV. OUT 5009.06 (S)167.59 LF 30" RCP @ 0.20%INLET 1-3STA 11+12.59RIM 5012.5±INV. IN 5008.73 (N)INV. OUT 5008.73 (E)99.98 LF 30" RCP @ 0.20%FES 1-1STA 10+00.00RIM 5011.3±INV. IN 5008.50 (W)PROPOSED
GROUND EXISTING
GROUND
21" CLAY SANITARY
STA.=17+50.13
INV.=5002.79TEE 1-12STA 18+77.04RIM 5013.8±INV. IN 5013.06 (N)INV. IN 5013.06 (E)INV. OUT 5013.06 (S)8" PVC WATER
STA.=14+48.99
TOP=5007.73
18" MIN.
8" PVC WATER
STA.=12+91.73
TOP=5007.33
18" MIN.
18" CLAY SANITARY
STA.=17+33.69
INV.=5005.41
8" PVC SANITARY
STA.=14+59.16
INV.=5006.44
PRIVATE
BEND 1-13STA 19+09.45RIM 5014.0±INV. IN 5013.22 (NE)INV. OUT 5013.22 (S)TEE 1-2STA 10+12.61INV. 5008.53 (W)INV. 5008.64 (S)INV. 5008.53 (E)TEE 1-6STA 14+35.08INV. 5009.41 (W)INV. 5009.78 (N)INV. 5009.41 (E)4" PVC WATER
STA.=12+54.63
TOP=5008.48
4" PVC WATER
STA.=12+25.01
TOP=5008.58
4" PVC WATER
STA.=11+81.46
TOP=5006.19
4" PVC WATER
STA.=11+38.07
TOP=5005.98
4" PVC SANITARY
STA.=12+69.63
INV.=5005.65
4" PVC SANITARY
STA.=12+15.01
INV.=5005.92
4" PVC SANITARY
STA.=11+71.46
INV.=5006.14
4" PVC SANITARY
STA.=11+30.07
INV.=5006.34
4" PVC SANITARY
STA.=10+89.76
INV.=5006.93
4" PVC SANITARY
STA.=11+25.05
INV.=5006.37
13.58 LF 24" RCP @ 0.50%
12.61 LF
30" RCP
@ 0.20%
2-YR HGL
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 43
C 620PLAN & PROFILESTORM DRAIN 127
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
NORTH
( IN FEET )
1 inch = ft.
Feet05050
50
100 150
PROFILE SCALE:
STORM DRAIN 1
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
NOTES:
W
EXISTING SANITARY SEWER SS
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPOSED LOT LINE
PROJECT BOUNDARY
EXISTING RIGHT OF WAY
EXISTING STORM SEWER
EASEMENT LINE
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES.
3.PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND
STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF
FLARED END SECTIONS.
4.ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND
INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY CITY OF
FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE
R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE
'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443
FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE).
5.CONTRACTOR SHALL CONFIRM THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR
THEIR PROPOSED METHODS OF INSTALLATION (i.e., WITHIN PRE-CASTER'S
TOLERANCES, ETC.).
6.CONTRACTOR SHALL DEFLECT SERVICE LINES TO AVOID STORM DRAIN LINES.
PROPOSED RIGHT OF WAY
INLET SUMMARY TABLE
DESIGN
POINT
DESIGN INLET
LABEL INLET TYPE INLET SIZE
A2 INLET 2-5 Area Inlet 2' X 15'
B1 INLET 3-4 Nyoplast 30 in.30"
B2 INLET 1-3 Area Inlet 2' X 1.35'
B3 INLET 1-4 Area Inlet 2' X 1.35'
B6 INLET 1-9.5 Type R 5'
B7 INLET 1-9.1 Type R 5'
B9 INLET 1-5.1 Type R 5'
B10 INLET 1-6.3 Type R 5'
D3 INLET 6-2 Type R 5'
D5 INLET 4-4A Area Inlet 4' X 1.35'
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
STORM
DRAIN 1
S SSWWFFFEEEEE
T
T
GEETTSWWW
EWW
FSSVAULTELECVAULTELECEEWWUDGGGEEEGGG G G G G
W
EEEEE18" SSWEEEWGGW S
EEETEEE
FDCFDCFDCFDCGFFFFGGS SSFSF
F F
SF WF
GG
GGGGGGV.P.VAULTELECSSS18" SS18" SS18" SS18" SS18" SS18" SS21" SS21" SS21" SS21" SS21" SS21" SS8" SS8" SSWFDCEEUDUDUDUD
UD UDUDUDUDUDUDWWWSH YD30" W30" W30" W30" W30" W30" W30" WLANDMARK
APARTMENTS
EXISTING 21"
SANITARY SEWER
EXISTING 8" PVC
WATER
PROPOSED FH
SANITARY LINE D
SEE SHEET C 612
PROPOSED GAS
PROPOSED
ELECTRIC
STORM DRAIN 1
SEE SHEET C 620
EXISTING 18"
SANITARY SEWER
EXISTING 30"
WATER
STORM DRAIN 1-8
SEE SHEET C 622
119.72 LF 15
"
R
C
P
@
1
.
0
0
%
STMH 1-5
STA 10+00.00
N: 1449285.73
E: 3113722.21
INLET 1-5.1
STA 11+19.72
N: 1449167.00
E: 3113706.82
BUILDING 7
BUILDING 4
BUILDING 5
BUILDING 8
BUILDING 18
BUILDING 17
BUILDING 16
BUILDING 15 BUILDING 14
BUILDING 13
BUILDING 12
BUILDING 11
BUILDING 10
PROPOSED FH
STORM DRAIN 1-6
SEE THIS SHEET - RIGHT
SANITARY LINE C
SEE SHEET C 612
4995
5000
5005
5010
5015
5020
5025
5030
4995
5000
5005
5010
5015
5020
5025
5030
9+50 10+00 11+00 11+50
PRIVATE
STMH 1-5STA 10+00.00RIM 5014.2±INV. IN 5009.34 (W)INV. IN 5009.34 (S)INV. OUT 5009.34 (E)119.72 LF 15" RCP
@
1
.
0
0
%INLET 1-5.1STA 11+19.72RIM 5014.1±INV. OUT 5010.54 (N)EXISTING
GROUND
PROPOSED
GROUND
S SSWWFFFEEEEE
T
T
GEETSWWW
WW
FSSVAULTELECEEWWGGG G G G GW
EEEE18" SSWEEEWGGW S
EEEEEEFDCFDCFDCFDCGFFFFGGS SSFSF
F F
SF WF
GG
GGGGV.P.VAULTELECSSS18" SS18" SS18" SS18" SS18" SS18" SS18" SS21" SS21" SS21" SS21" SS21" SS8" SS8" SSWFDCS EEEEUDUD
UDUDUDUDUDUD
UD
UD UDUDUDUDUDUDSSSSWWWSHYDLANDMARK
APARTMENTS
EXISTING 21"
SANITARY SEWER
EXISTING 8" PVC
WATER
PROPOSED FH
SANITARY LINE D
SEE SHEET C 612
PROPOSED GAS
PROPOSED
ELECTRIC
STORM DRAIN 1
SEE SHEET C 620
EXISTING 18"
SANITARY SEWER
EXISTING 30"
STORM DRAIN 1-8
SEE SHEET C 622
49.05 LF
8" HDPE
@ 0.40%
TEE 1-6.2
STA 10+64.67
N: 1449347.60
E: 3113706.00
23.81 LF
8" HDPE
@ 0.40%
INLET 1-6.3
STA 10+88.48
N: 1449371.37
E: 3113707.43
26.35 LF
8" HDPE
@ 0.40%
INLET 1-6.4
STA 11+14.83
N: 1449385.12
E: 3113729.90
BEND 1-6.1
STA 10+15.62
N: 1449298.55
E: 3113705.97
15.62 LF 8" HDPE @ 0.40%
TEE 1-6
STA 10+00.00
N: 1449283.20
E: 3113708.87
STORM DRAIN 1-5
SEE THIS SHEET - LEFT
BUILDING 7
BUILDING 4
BUILDING 5
BUILDING 8
BUILDING 18
BUILDING 17
BUILDING 16
BUILDING 15 BUILDING 14
BUILDING 13
BUILDING 12
BUILDING 11
BUILDING 10
PROPOSED FH
SANITARY LINE C
SEE SHEET C 612
4995
5000
5005
5010
5015
5020
5025
5030
4995
5000
5005
5010
5015
5020
5025
5030
9+009+00 10+00 11+00 12+00
PRIVATE
EXISTING
GROUND
PROPOSED
GROUNDTEE 1-6STA 10+00.00INV. 5009.41 (W)INV. 5009.78 (N)INV. 5009.41 (E)15.62 LF
8" HDPE
@ 0.40%BEND 1-6.1STA 10+15.62INV. 5009.85 (N)INV. 5009.85 (S)49.05 LF
8" HDPE
@ 0.40%TEE 1-6.2STA 10+64.67INV. 5010.04 (N)INV. 5010.17 (W)INV. 5010.04 (S)23.81 LF
8" HDPE
@ 0.40%INLET 1-6.3STA 10+88.48RIM 5013.1±INV. IN 5010.14 (NE)INV. OUT 5010.14 (S)26.35 LF
8" HDPE
@ 0.40%INLET 1-6.4STA 11+14.83RIM 5011.6±INV. OUT 5010.24 (SW)SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 43
C 621PLAN & PROFILESTORM DRAINS 1-5 & 1-628
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
( IN FEET )
1 inch = ft.
Feet05050
50
100 150
PROFILE SCALE:
STORM DRAIN 1-5
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
NOTES:
W
EXISTING SANITARY SEWER SS
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPOSED LOT LINE
PROJECT BOUNDARY
EXISTING RIGHT OF WAY
EXISTING STORM SEWER
EASEMENT LINE
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES.
3.PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND
STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF
FLARED END SECTIONS.
4.ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND
INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY CITY OF
FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE
R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE
'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443
FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE).
5.CONTRACTOR SHALL CONFIRM THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR
THEIR PROPOSED METHODS OF INSTALLATION (i.e., WITHIN PRE-CASTER'S
TOLERANCES, ETC.).
6.CONTRACTOR SHALL DEFLECT SERVICE LINES TO AVOID STORM DRAIN LINES.
PROPOSED RIGHT OF WAY
INLET SUMMARY TABLE
DESIGN
POINT
DESIGN INLET
LABEL INLET TYPE INLET SIZE
A2 INLET 2-5 Area Inlet 2' X 15'
B1 INLET 3-4 Nyoplast 30 in.30"
B2 INLET 1-3 Area Inlet 2' X 1.35'
B3 INLET 1-4 Area Inlet 2' X 1.35'
B6 INLET 1-9.5 Type R 5'
B7 INLET 1-9.1 Type R 5'
B9 INLET 1-5.1 Type R 5'
B10 INLET 1-6.3 Type R 5'
D3 INLET 6-2 Type R 5'
D5 INLET 4-4A Area Inlet 4' X 1.35'
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
STORM
DRAINS
1-5 & 1-6
PROFILE SCALE:
STORM DRAIN 1-6
NORTH
S
SSS
SWWFFEEEGGGGGEETTTTEFVAULTELECVAULTELECEEEEEEEWWEGGUDEEEEEEEGEEEWEEEESSET
FDCFDCFDCFDCGGG
GGGGGG G
GGGGGGGGGTESSS
S18" SS18" SS18" SS18" SS18" SS18" SS21" SS21" SS21" SS21" SS21" SS21" SS30" W30" W30" W30" W30" W30" W30" W30" WB
B
B
B
B
B
B
B
B
B
B
BB
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
BB
B
B
B
B
B
B
B
B
B
B
B
EXISTING 21"
SANITARY SEWER
PROPOSED FH SANITARY LINE B
SEE SHEET C 612
TEE 1-8
STA 10+00.00
N: 1449263.61
E: 3113566.09
86.73 LF 8" HDPE @ 0.50%
BASIN 1-8.1
STA 10+86.73
N: 1449176.89
E: 3113565.94
107.78 LF 8" HDPE @ 0.50%
BASIN 1-8.2
STA 11+94.51
N: 1449069.11
E: 3113565.89
STORM DRAIN 4
SEE SHEET C 624
STORM DRAIN 4-4A
SEE SHEET C 624
STORM DRAIN 4-4B
SEE SHEET C 624
6'
T
R
A
I
L
STORM DRAIN 5
SEE SHEET C 625
PROPOSED GAS
PROPOSED
ELECTRIC
STORM DRAIN 1
SEE SHEET C 620
EXISTING 18"
SANITARY SEWER
PROPOSED
RETAINING WALL
EXISTING 30"
WATER
STORM DRAIN 1-9
SEE THIS SHEET - RIGHT
BUILDING
7
BUILDING
6
BUILDING
5
BUILDING
4
BUILDING
2
STORM DRAIN
SEE SHEET C 612
4995
5000
5005
5010
5015
5020
5025
5030
4995
5000
5005
5010
5015
5020
5025
5030
9+50 10+00 11+00 12+00 12+50TEE 1-8STA 10+00.00RIM 5012.5±INV. IN 5010.14 (W)INV. IN 5010.81 (S)INV. OUT 5010.14 (E)86.73 LF 8" HDPE @ 0.50%BASIN 1-8.1STA 10+86.73RIM 5014.2±INV. IN 5011.24 (S)INV. OUT 5011.24 (N)107.78 LF 8" HDPE @ 0.50%BASIN 1-8.2STA 11+94.51RIM 5013.9±INV. OUT 5011.78 (N)EXISTING
GROUND
PROPOSED
GROUND
8" PVC WATER
STA.=10+11.25
TOP=5009.30
PRIVATE
S
SSS
SWWFFEEEGGGGGEETTTTEFVAULTELECVAULTELECEEEEEEEWWEGGUDEEEEEEEGEEEWEEEESSET
FDCFDCFDCFDCGGG
GGGGGG G
GGGGGGGGGTESSS
S18" SS18" SS18" SS18" SS18" SS18" SS21" SS21" SS21" SS21" SS21" SS21" SS30" W30" W30" W30" W30" W30" W30" W30" WB
B
B
B
B
B
B
B
B
B
B
BBB
B
B
BB
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
BBB
B
B
BB
B
B
B
B
B
B
EXISTING 21"
SANITARY SEWER
PROPOSED FH SANITARY LINE B
SEE SHEET C 612
STORM DRAIN 4
SEE SHEET C 624
STORM DRAIN 4-4A
SEE SHEET C 624
STORM DRAIN 4-4B
SEE SHEET C 624
6'
T
R
A
I
L
STORM DRAIN 5
SEE SHEET C 625
PROPOSED GAS
PROPOSED
ELECTRIC
STMH 1-9
STA 10+00.00
N: 1449263.33
E: 3113468.37
31.29 LF
24" RCP
@ 0.50%
TEE 1-9.2
STA 10+51.45
N: 1449211.97
E: 3113468.34
19.31 LF
15" HDPE
@ 0.50%
TEE 1-9.4
STA 10+97.80
N: 1449165.61
E: 3113468.32
30.03 LF
15" HDPE
@ 0.50%
STORM DRAIN 1
SEE SHEET C 620
EXISTING 18"
SANITARY SEWER
PROPOSED
RETAINING WALL
EXISTING 30"
WATER
STORM DRAIN 1-8
SEE THIS SHEET - LEFT
BUILDING
7
BUILDING
6
BUILDING
5
BUILDING
4
BUILDING
2
STORM DRAIN
SEE SHEET C 612
INLET 1-9.5
STA 11+27.84
N: 1449135.62
E: 3113469.80
9.78 LF
12" HDPE
@ 0.50%
BEND 1-9.6
STA 11+37.62
N: 1449130.47
E: 3113478.11
5.56 LF
12" HDPE
@ 0.50%
TEE 1-9.7
STA 11+43.19
N: 1449124.91
E: 3113478.11
18.86 LF
12" HDPE
@ 0.50%
TEE 1-9.8
STA 11+62.04
N: 1449106.05
E: 3113478.10
11.80 LF 12" HDPE @ 0.50%
TEE 1-9.9
STA 11+69.40
N: 1449094.25
E: 3113478.09
TEE 1-9.3
STA 10+71.13
N: 1449192.66
E: 3113468.33
INLET 1-9.1
STA 10+31.70
N: 1449232.08
E: 3113469.85
20.17 LF
15" HDPE
@ 0.50%
4995
5000
5005
5010
5015
5020
5025
5030
4995
5000
5005
5010
5015
5020
5025
5030
9+009+00 10+00 11+00 12+00 13+00
EXISTING
GROUND
PROPOSED
GROUND
30.03 LF
15" HDPE
@ 0.50%
19.31 LF
15" HDPE
@ 0.50%
31.29 LF
24" RCP
@ 0.50%
20.17 LF
15" HDPE
@ 0.50%
9.78 LF
12" HDPE
@ 0.50%
5.56 LF
12" HDPE
@ 0.50%
8" PVC WATER
STA.=10+10.93
TOP=5008.93
PRIVATE
STMH 1-9STA 10+00.00RIM 5015.5±INV. IN 5012.06 (N)INV. IN 5010.63 (S)INV. OUT 5010.63 (E)INLET 1-9.1STA 10+31.29RIM 5015.4±INV. IN 5010.79 (S)INV. OUT 5010.79 (N)TEE 1-9.2STA 10+51.45INV. 5010.89 (S)INV. 5011.02 (E)INV. 5010.89 (N)TEE 1-9.3STA 10+70.75INV. 5010.98 (S)INV. 5011.45 (E)INV. 5010.98 (N)TEE 1-9.4STA 10+97.80INV. 5011.12 (S)INV. 5011.06 (E)INV. 5011.12 (N)INLET 1-9.5STA 11+27.84RIM 5015.4±INV. IN 5011.27 (SE)INV. OUT 5011.27 (N)BEND 1-9.6STA 11+37.62INV. 5011.32 (S)INV. 5011.32 (NW)TEE 1-9.7STA 11+43.19INV. 5011.60 (E)INV. 5011.34 (S)INV. 5011.34 (N)TEE 1-9.8STA 11+62.04INV. 5011.44 (S)INV. 5011.59 (E)INV. 5011.44 (N)TEE 1-9.10STA 11+79.51INV. 5011.46 (E)INV. 5011.69 (S)INV. 5011.69 (N)INLET 1-9.11STA 12+10.79RIM 5015.0±INV. OUT 5011.85 (N)27.04 LF
15" HDPE
@ 0.50%
18.86 LF
12" HDPE
@ 0.50%
11.80 LF
12" HDPE
@ 0.50%
5.67 LF
8" HDPE
@ 0.50%
31.29 LF
8" HDPE
@ 0.50%
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 43
C 622PLAN & PROFILESTORM DRAINS 1-8 & 1-929
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
( IN FEET )
1 inch = ft.
Feet05050
50
100 150
PROFILE SCALE:
STORM DRAIN 1-8
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
NOTES:
W
EXISTING SANITARY SEWER SS
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPOSED LOT LINE
PROJECT BOUNDARY
EXISTING RIGHT OF WAY
EXISTING STORM SEWER
EASEMENT LINE
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES.
3.PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND
STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF
FLARED END SECTIONS.
4.ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND
INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY CITY OF
FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE
R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE
'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443
FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE).
5.CONTRACTOR SHALL CONFIRM THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR
THEIR PROPOSED METHODS OF INSTALLATION (i.e., WITHIN PRE-CASTER'S
TOLERANCES, ETC.).
6.CONTRACTOR SHALL DEFLECT SERVICE LINES TO AVOID STORM DRAIN LINES.
PROPOSED RIGHT OF WAY
INLET SUMMARY TABLE
DESIGN
POINT
DESIGN INLET
LABEL INLET TYPE INLET SIZE
A2 INLET 2-5 Area Inlet 2' X 15'
B1 INLET 3-4 Nyoplast 30 in.30"
B2 INLET 1-3 Area Inlet 2' X 1.35'
B3 INLET 1-4 Area Inlet 2' X 1.35'
B6 INLET 1-9.5 Type R 5'
B7 INLET 1-9.1 Type R 5'
B9 INLET 1-5.1 Type R 5'
B10 INLET 1-6.3 Type R 5'
D3 INLET 6-2 Type R 5'
D5 INLET 4-4A Area Inlet 4' X 1.35'
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
STORM
DRAINS
1-8 & 1-9
PROFILE SCALE:
STORM DRAIN 1-9
NORTH
4995
5000
5005
5010
5015
5020
5025
5030
4995
5000
5005
5010
5015
5020
5025
5030
9+5010+0011+0011+50
40.32 LF
18" RCP
@ 1.20%
4.75 LF
18" RCP
@ 0.20%BASIN 2-2 (w WEIR)STA 10+30.08RIM 5012.8±INV. IN 5008.11 (N)INV. IN 5008.52 (W)INV. OUT 5008.11 (S)30.08 LF
18" HDPE
@ 0.20%PIPE END 2-1STA 10+00.00RIM 5009.8±INV. IN 5008.05 (N)30" WATER
STA.=10+63.94
TOP=5006.68
18" MIN.
4.75 LF
18" RCP
@ 0.20%BASIN 2-3STA 10+34.83RIM 5012.7±INV. IN 5008.12 (N)INV. IN 5008.51 (W)INV. OUT 5008.12 (S)PRIVATE
INLET 2-5STA 10+79.90RIM 5011.8±INV. OUT 5008.62 (SW)BASIN 2-4STA 10+39.58RIM 5012.6±INV. IN 5008.13 (NE)INV. IN 5008.56 (W)INV. OUT 5008.13 (S)PROPOSED
GROUND
EXISTING
GROUND
2-YR HGL MHUDUDUDUDUDUDUDUDUDUDMHX30" W30" W30" W30" WX
X
X
X
X
X
X X
X
30" W21" SS 21" SS21" SS
EW
UD
UD
UDGGEEGG G
EEW S TS SF F
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B BB
B
B
B
B
B
B
B
B
B
B
BB B
B
B
B BB
BB
B
B
B
B
B
B
B
B
B
B
B BB
B BB
B
B
B
B
B BB
B BB
X BBBBB
B
B
B
B
X
X
OVERFLOW BASIN 3-4
STA 11+30.88
N: 1449013.73
E: 3114045.32
45.71 LF 24" HDPE @ 0.50%
STMH 3-3
STA 10+85.18
N: 1448971.00
E: 3114061.55
47.07 LF 24" HDPE @ 0.50%
STYMH 3-2
STA 10+38.11
N: 1448924.04
E: 3114064.79
39.74 LF
24" HDPE
@ 0.50%
FES 3-1
STA 9+98.37
N: 1448911.11
E: 3114027.21
CANAL IMPOR
T
A
T
I
O
N
SPRING CREEKWALL
E
N
B
E
R
G
D
R
BUILDING 10
BUILDING 9
PROPOSED 2'
CONCRETE PAN
PROPOSED GAS
EXISTING 30"
WATER
STORM DRAIN 1
SEE SHEET C 620
STORM DRAIN 5
SEE SHEET C 625
STORM DRAIN 5-2
SEE SHEET C 625
PROPOSED STORM
CHAMBERS 1
FIRE HYDRANT
UNDERDRAIN
SEE SHEET C 626
RAIN
GARDEN
4995
5000
5005
5010
5015
5020
5025
5030
4995
5000
5005
5010
5015
5020
5025
5030
9+5010+0011+0012+00 OVERFLOW BASIN 3-4STA 11+30.88RIM 5010.7±INV. OUT 5008.31 (S)45.71 LF
24" HDPE
@ 0.50%STMH 3-3STA 10+85.18RIM 5013.2±INV. IN 5008.08 (N)INV. OUT 5008.08 (S)47.07 LF
24" HDPE
@ 0.50%STYMH 3-2STA 10+38.11RIM 5012.0±INV. IN 5007.84 (N)INV. OUT 5007.84 (W)39.74 LF
24" HDPE
@ 0.50%FES 3-1STA 9+98.37RIM 5009.1±INV. IN 5007.64 (E)30" WATER
STA.=11+07.89
TOP=5006.18
18" MIN.
PRIVATE
PROPOSED
GROUND
EXISTING
GROUND 100-YR
HGLMHUDUDUDUDUDUDUDUDUDUDMHX30" W30" W30" W30" WX
X
X
X
X
X
X X
X
30" WWINNE GRANT R/JOHNELLE S1821 WALLENBERG DRERIKSEN CHRISTOPHER M1825 WALLENBERG DR21" SS 21" SS 21" SS
EW
UD
UD
UDGGEEGG G
EEW S TS SF F
B
B
B
B
B
B
B
B
B
B
B
BB B
B BB
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B BBBB
B
B
B
B
B
B
B
B
B
B
B BB
B BB
B
B
B
B
B BB
B BB
X BBBBBB
B
B
B
X
X
CANAL IMPOR
T
A
T
I
O
N
SPRING CREEKWALL
E
N
B
E
R
G
D
R
BUILDING 10
BUILDING 9
PROPOSED 2'
CONCRETE PAN
PROPOSED GAS
EXISTING 30"
WATER
STORM DRAIN 1
SEE SHEET C 620
STORM DRAIN 5
SEE SHEET C 625
STORM DRAIN 5-2
SEE SHEET C 625
PROPOSED STORM
CHAMBERS 1
FIRE HYDRANT
UNDERDRAIN
SEE SHEET C 626
3 - 78.12 LF 30"x19" CONCRETE ELLIPTICAL PIPE @ 1.75%
STORM DRAIN 2
SEE THIS SHEET - LEFT
STORM DRAIN 3
SEE THIS SHEET - RIGHT
PIPE END 2-1A
STA 10+00.00
N: 1448934.16
E: 3113964.02
INLET 2-5A
STA 10+76.32
N: 1449003.52
E: 3113996.34
RAIN
GARDEN
4990
4995
5000
5005
5010
5015
5020
5025
4990
4995
5000
5005
5010
5015
5020
5025
9+50 10+00 11+00 11+50
3 - 76.52 LF 30"x19" CONCRETE
ELLIPTICAL PIPE @ 1.79%PIPE END 2-1ASTA 10+00.00RIM 5009.9±INV. IN 5007.97 (NE)INLET 2-5ASTA 10+76.32RIM 5011.3±INV. OUT 5009.34 (SW)PRIVATE
PROPOSED
GROUND
EXISTING
GROUND
100-YR
HGL
30" WATER
STA.=10+67.95
TOP=5006.58MHUDUDUDUDUDUDUDUDUDUDMHX30" W30" W30" W30" WX
X
X
X
X
X
X X
X
30" WWINNE GRANT R/JOHNELLE S1821 WALLENBERG DRERIKSEN CHRISTOPHER M1825 WALLENBERG DR21" SS 21" SS 21" SS
EW
UD
UD
UDGGEEGG G
EEW S TS SF F
B
B
B
B
B
B
B
B
B
B
B
BB B
B BB
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B BBBB
B
B
B
B
B
B
B
B
B
B
B BB
B BB
B
B
B
B
B BB
B BB
X BBBBBB
B
B
B
X
X
INLET 2-5
STA 10+79.90
N: 1449004.76
E: 3113993.09
40.32 LF 18" RCP @ 1.20%
BASIN 2-4
STA 10+39.58
N: 1448973.97
E: 3113967.05
4.75 LF 18" RCP @ 0.20%
BASIN 2-2 (w WEIR)
STA 10+30.08
N: 1448964.47
E: 3113967.05
30.08 LF 18" HDPE @ 0.20%
PIPE END 2-1
STA 10+00.00
N: 1448935.08
E: 3113960.64
CANAL IMPOR
T
A
T
I
O
N
SPRING CREEKWALL
E
N
B
E
R
G
D
R
BUILDING 10
BUILDING 9
PROPOSED 2'
CONCRETE PAN
PROPOSED GAS
EXISTING 30"
WATER
STORM DRAIN 1
SEE SHEET C 620
STORM DRAIN 5
SEE SHEET C 625
STORM DRAIN 5-2
SEE SHEET C 625
PROPOSED STORM
CHAMBERS 1
FIRE HYDRANT
STORM DRAIN 3
SEE THIS SHEET - RIGHT
UNDERDRAIN
SEE SHEET C 626
BASIN 2-3
STA 10+34.83
N: 1448969.22
E: 3113967.05
4.75 LF 18" RCP @ 0.20%
RAIN
GARDEN
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 43
C 623PLAN & PROFILESTORM DRAIN 2, 2A, & 330
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
NORTH
( IN FEET )
1 inch = ft.
Feet05050
50
100 150
PROFILE SCALE:
STORM DRAIN 2
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
NOTES:
W
EXISTING SANITARY SEWER SS
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPOSED LOT LINE
PROJECT BOUNDARY
EXISTING RIGHT OF WAY
EXISTING STORM SEWER
EASEMENT LINE
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES.
3.PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND
STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF
FLARED END SECTIONS.
4.ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND
INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY CITY OF
FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE
R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE
'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443
FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE).
5.CONTRACTOR SHALL CONFIRM THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR
THEIR PROPOSED METHODS OF INSTALLATION (i.e., WITHIN PRE-CASTER'S
TOLERANCES, ETC.).
6.CONTRACTOR SHALL DEFLECT SERVICE LINES TO AVOID STORM DRAIN LINES.
PROPOSED RIGHT OF WAY
INLET SUMMARY TABLE
DESIGN
POINT
DESIGN INLET
LABEL INLET TYPE INLET SIZE
A2 INLET 2-5 Area Inlet 2' X 15'
B1 INLET 3-4 Nyoplast 30 in.30"
B2 INLET 1-3 Area Inlet 2' X 1.35'
B3 INLET 1-4 Area Inlet 2' X 1.35'
B6 INLET 1-9.5 Type R 5'
B7 INLET 1-9.1 Type R 5'
B9 INLET 1-5.1 Type R 5'
B10 INLET 1-6.3 Type R 5'
D3 INLET 6-2 Type R 5'
D5 INLET 4-4A Area Inlet 4' X 1.35'
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
STORM DRAIN 3
PROFILE SCALE:
STORM
DRAIN
2 & 3
STORM DRAIN 2A
PROFILE SCALE:
SWFFE
E
E
E
E
E
G G G G G
G
G
G
G
G GF
G
TT
TSEWW
UD
E E E E EE E EE EEE
SSEFDC
FDC
FDC
WG
GGG G G G GG GE
ELEC
30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W
BINLET 1-7
STA 13+65.00
N: 1449021.27
E: 3113479.34
FES 4-1
STA 10+00.00
N: 1448734.73
E: 3113345.36 145.20 LF 18" HDPE @ 0.50%BASIN 4-3 (w WEIR)
STA 11+37.27
N: 1448828.58
E: 3113428.48
STMH 4-4
STA 12+82.47
N: 1448973.78
E: 3113428.56
75.80 LF 24" RCP @ 0.50%
STMH 4-2
STA 10+75.80
N: 1448805.94
E: 3113371.34
61.47 LF 24" RCP @ 0.50%
STORM DRAIN 4-4B
SEE THIS SHEET - RIGHT
STORM DRAIN 4-4A
SEE THIS SHEET - MIDDLE
SANITARY LINE A
SEE SHEET C 610
PROPOSED 8"
PVC WATER
PROPOSED 8"
PVC WATER
10' TR
A
I
L
STORM DRAIN 6
SEE SHEET C 626
PROPOSED
STORMTECH
CHAMBERS
26.20 LF 8" HDPE @ 0.50%
21.52 LF 8" HDPE @ 0.50%
BEND 4-5
STA 13+08.67
N: 1448973.65
E: 3113454.76
BEND 4-6
STA 13+30.19
N: 1448988.79
E: 3113470.05
23.20 LF 8" HDPE @ 0.50%
BUILDING 3
BUILDING 4 BUILDING 5
5000
5005
5010
5015
5020
5025
5030
5000
5005
5010
5015
5020
5025
5030
9+50 10+00 11+00 12+00 13+00 14+00 14+50
PROPOSED
GROUND
EXISTING
GROUND STMH 4-4STA 12+82.47RIM 5015.5±INV. IN 5012.50 (E)INV. IN 5012.50 (N)INV. IN 5012.50 (W)INV. OUT 5012.50 (S)145.20 LF 18" HDPE @ 0.50%BASIN 4-3 (w WEIR)STA 11+37.27RIM 5016.3±INV. IN 5011.77 (N)INV. IN 5012.25 (E)INV. IN 5012.33 (E)INV. OUT 5011.77 (W)61.47 LF 24" RCP @ 0.50%
75.80 LF 24" RCP @ 0.50%STMH 4-2STA 10+75.80RIM 5015.9±INV. IN 5011.46 (E)INV. OUT 5011.46 (S)FES 4-1STA 10+00.00RIM 5013.5±INV. IN 5011.08 (N)26.20 LF 8" HDPE @ 0.50%
30" WATER
STA.=13+35.07
TOP=5008.36
8" PVC WATER
STA.=11+02.96
TOP=5009.85 BEND 4-5STA 13+08.67INV. 5012.63 (NE)INV. 5012.63 (W)21.52 LF 8" HDPE @ 0.50%
23.20 LF 8" HDPE @ 0.50%BEND 4-7STA 13+53.39INV. 5012.85 (NE)INV. 5012.85 (S)PUBLIC
100-YR
HGL BEND 4-6STA 13+30.19INV. 5012.73 (N)INV. 5012.73 (SW)SSWFFF
G
T
TSEEWW SSEFDC
FDC
FDCIR W GGGGGGGGGGG G
H2O
TRAFFIC
VAULTT SVAULT
ELEC
VAULT
ELEC
VAULT
ELEC
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
ELEC
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
EEEEEETTTTTGGGGGGGGEEEEE30" W30" W 30" W 30" W 30" W 30" W 30" W
PROPOSED
GAS
143.18 LF 12" HDPE @ 0.50%
BEND 4-4.3
STA 12+01.45
N: 1448981.69
E: 3113230.05
19.64 LF 12" HDPE @ 0.50%
BEND 4-4.5
STA 12+38.22
N: 1449012.73
E: 3113216.19
13.31 LF
12" HDPE
@ 0.50%
INLET 4-4.7
STA 12+87.08
N: 1449012.95
E: 3113167.33
STMH 4-4
STA 10+00.00
N: 1448973.78
E: 3113428.56
EXISTING 30"
WATER
SANITARY LINE A
SEE SHEET C 610
PROPOSED 8"
PVC WATER
STORM DRAIN 4-4A
SEE THIS SHEET - MIDDLE
STORM DRAIN 4
SEE THIS SHEET - LEFT
SANITARY LINE A2
SEE SHEET C 610
BUILDING 2
BUILDING 3
BUILDING 1
9.94 LF 12" HDPE @ 0.50%
BEND 4-4.2
STA 11+91.51
N: 1448974.63
E: 3113237.05
48.33 LF
12" HDPE
@ 0.50%
TEE 4-4.1
STA 11+43.18
N: 1448974.42
E: 3113285.38
17.13 LF 12" HDPE @ 0.50%
BEND 4-4.4
STA 12+18.58
N: 1448998.82
E: 3113230.06
SF EGGTTTSEEEEEEESSEFDCWGGGGGGE
30" W30" W30" W30" W30" W30" W30" WSTMH 4-4
STA 10+00.00
N: 1448973.78
E: 3113428.56
6.66 LF 15" RCP @ 0.50%
INLET 4-4A
STA 10+00.03
N: 1448980.44
E: 3113428.56
STORM DRAIN 4
SEE THIS SHEET - LEFT
STORM DRAIN 4-4B
SEE THIS SHEET - RIGHT
PROPOSED GAS
PROPOSED
ELECTRIC
PROPOSED 8"
PVC WATER
EXISTING
30" WATER
BUILDING 3
BUILDING 4
BUILDING 5
5000
5005
5010
5015
5020
5025
5030
5000
5005
5010
5015
5020
5025
5030
9+5010+0011+0012+0013+0013+50
PROPOSED
GROUND
EXISTING
GROUND STMH 4-4STA 10+00.00RIM 5015.5±INV. IN 5012.50 (E)INV. IN 5012.50 (N)INV. IN 5012.50 (W)INV. OUT 5012.50 (S)143.18 LF 12" HDPE @ 0.50%BEND 4-4.3STA 12+01.45INV. 5013.51 (N)INV. 5013.51 (SE)19.64 LF
12" HDPE
@ 0.50%BEND 4-4.5STA 12+38.22INV. 5013.70 (W)INV. 5013.70 (SE)INLET 4-4.7STA 12+87.08RIM 5016.1±INV. OUT 5013.95 (E)30" WATER
STA.=12+13.58
TOP=5007.42TEE 4-4.6STA 12+51.53INV. 5014.02 (N)INV. 5013.77 (W)INV. 5013.77 (E)13.31 LF
12" HDPE
@ 0.50%
35.55 LF
12" HDPE
@ 0.50%BEND 4-4.4STA 12+18.58INV. 5013.60 (NW)INV. 5013.60 (S)17.13 LF
12" HDPE
@ 0.50%
PRIVATE
48.33 LF
12" HDPE
@ 0.50%TEE 4-4.1STA 11+43.18INV. 5013.22 (W)INV. 5013.22 (N)INV. 5013.22 (E)BEND 4-4.2STA 11+91.51INV. 5013.46 (NW)INV. 5013.46 (E)5000
5005
5010
5015
5020
5025
5030
5000
5005
5010
5015
5020
5025
5030
9+50 10+00 11+00STMH 4-4STA 10+11.51RIM 5015.5±INV. IN 5012.50 (E)INV. IN 5012.50 (N)INV. IN 5012.50 (W)INV. OUT 5012.50 (S)6.66 LF
15" RCP
@ 0.50%INLET 4-4ASTA 10+18.17RIM 5015.3±INV. OUT 5012.53 (S)PROPOSED
GROUND
EXISTING
GROUND
PRIVATE
100-YR
HGL
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 43
C 624PLAN & PROFILESTORM DRAINS 4, 4-4A, & 4-431
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
( IN FEET )
1 inch = ft.
Feet05050
50
100 150
PROFILE SCALE:
STORM DRAIN 4
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
NOTES:
W
EXISTING SANITARY SEWER SS
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPOSED LOT LINE
PROJECT BOUNDARY
EXISTING RIGHT OF WAY
EXISTING STORM SEWER
EASEMENT LINE
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES.
3.PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND
STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF
FLARED END SECTIONS.
4.ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND
INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY CITY OF
FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE
R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE
'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443
FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE).
5.CONTRACTOR SHALL CONFIRM THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR
THEIR PROPOSED METHODS OF INSTALLATION (i.e., WITHIN PRE-CASTER'S
TOLERANCES, ETC.).
6.CONTRACTOR SHALL DEFLECT SERVICE LINES TO AVOID STORM DRAIN LINES.
PROPOSED RIGHT OF WAY
INLET SUMMARY TABLE
DESIGN
POINT
DESIGN INLET
LABEL INLET TYPE INLET SIZE
A2 INLET 2-5 Area Inlet 2' X 15'
B1 INLET 3-4 Nyoplast 30 in.30"
B2 INLET 1-3 Area Inlet 2' X 1.35'
B3 INLET 1-4 Area Inlet 2' X 1.35'
B6 INLET 1-9.5 Type R 5'
B7 INLET 1-9.1 Type R 5'
B9 INLET 1-5.1 Type R 5'
B10 INLET 1-6.3 Type R 5'
D3 INLET 6-2 Type R 5'
D5 INLET 4-4A Area Inlet 4' X 1.35'
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
PROFILE SCALE:
STORM DRAIN 4-4A STORM DRAIN 4-4
PROFILE SCALE:
NORTH NORTHNORTH
STORM 4
STORM 4-4B
STORM 4-4A
E
E
E
E
E
E
G G
G
G
G
G
G
G GTT
TSEWVAULT
ELEC UDUD
G GEE
E
G G G
UD
E E EE E EE E E ESSETTFW
G G G G GG GE
UDUDUDUDUDUDUDELEC
XX30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W
XXXXXXX30" W
WINNE GRANT R/JOHNELLE S
1821 WALLENBERG DR
ERIKSEN CHRISTOPHER M
1825 WALLENBERG DR
MCCOY JOHN H/SHERRY P
1900 S SHIELDS ST
2
1
"
S
S
2
1
"
S
S
2
1
"
S
S
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBSTMH 5-6
STA 17+18.99
N: 1448744.40
E: 3113441.50
STMH 5-5
STA 15+30.02
N: 1448824.98
E: 3113612.44
STMH 5-4
STA 13+57.85
N: 1448853.68
E: 3113782.20
OUTLET 5-7
STA 18+18.38
N: 1448717.70
E: 3113345.77
STMH 5-2
STA 10+80.18
N: 1448859.30
E: 3114045.64
STMH 5-3
STA 11+02.44
N: 1448838.71
E: 3114037.16
FES 5-1
STA 10+00.00
N: 1448864.84
E: 3114125.62
22.27 LF
18" HDPE
@ 0.60%
255.40 LF 18" HDPE @ 1.05
%
172.17 LF 1
8
"
H
D
P
E
@
0
.
5
0
%
188.9
8
L
F
1
8
"
H
D
P
E
@
0.
5
0
%
99.39 L
F
1
8
"
H
D
P
E
@
0
.
5
0
%
PROPOSED 2'
CONCRETE PAN CANAL IMPORTATIONSPRI
N
G
C
R
E
E
K
STORM DRAIN 4
SEE SHEET C 624
STORM DRAIN 4-4A
SEE SHEET C 624
STORM DRAIN 4-4B
SEE SHEET C 624
STORM DRAIN 2
SEE SHEET C 623
STORM DRAIN 3
SEE SHEET C 623
EXISTING 30"
WATERPROPOSED
ELECTRIC
PROPOSED
GAS
PROPOSED 8'
PVC WATER
SP
R
I
N
G
C
R
E
E
K
80.18 LF
24" RCP
@ 0.50%
UNDERDRAIN
SEE SHEET C 626
STORM DRAIN 5-2
SEE THIS SHEET-RIGHT
PROPOSED
FIRE HYDRANT
SANITARY LINE A
SEE SHEET C 610
BUILDING 3 BUILDING 4 BUILDING 5
BUILDING 1
4995
5000
5005
5010
5015
5020
5025
5030
4995
5000
5005
5010
5015
5020
5025
5030
9+5010+0011+0012+0013+0014+0015+0016+0017+0018+0018+50
22.27 LF
18" HDPE
@ 0.60%
255.40 LF 18"
H
D
P
E
@
1
.
0
5
%
172.17 LF 18" HDPE @ 0.50%
188.98 LF 18" HDPE @ 0.50%
99.39 LF 18" HDPE @ 0.50%STMH 5-6STA 17+18.99RIM 5014.8±INV. IN 5010.41 (W)INV. OUT 5010.41 (NE)STMH 5-5STA 15+30.02RIM 5014.9±INV. IN 5009.47 (SW)INV. OUT 5009.47 (E)STMH 5-4STA 13+57.85RIM 5014.6±INV. IN 5008.61 (W)INV. OUT 5008.61 (E)OUTLET 5-7STA 18+18.38RIM 5013.4±INV. OUT 5010.91 (E)STMH 5-2STA 10+80.18RIM 5010.5±INV. IN 5005.78 (S)INV. IN 5005.78 (W)INV. OUT 5004.87 (E)FES 5-1STA 10+00.00RIM 5006.3±INV. IN 5004.47 (W)EXISTING
GROUND
PROPOSED
GROUND
80.18 LF
24" RCP
@ 0.50%STMH 5-3STA 11+02.44RIM 5011.5±INV. IN 5005.91 (W)INV. OUT 5005.91 (N)PRIVATE UDG
TUDUDUDUDUDUDUDXX30" W 30" W
XXX30" W
BBBBBBBBBBBBBBBBBBBBBBBBBPROPOSED 2'
CONCRETE PAN CANAL IMPORTATIONSTORM DRAIN 2
SEE SHEET C 623
STORM DRAIN 3
SEE SHEET C 623
29.50 LF
15" HDPE
@ 3.30%
STMH 5-2
STA 10+00.00
N: 1448859.30
E: 3114045.64
OUTLET 5-2.1
STA 10+29.50
N: 1448849.58
E: 3114017.78
SP
R
I
N
G
C
R
E
E
K
UNDERDRAIN
SEE SHEET C 626
STORM DRAIN 5
SEE THIS SHEET-LEFT
4995
5000
5005
5010
5015
5020
5025
5030
4995
5000
5005
5010
5015
5020
5025
5030
9+5010+0011+00 STMH 5-2STA 10+00.00RIM 5010.5±INV. IN 5005.78 (S)INV. IN 5005.78 (W)INV. OUT 5004.87 (E)29.50 LF
15" HDPE
@ 3.30%OUTLET 5-2.1STA 10+29.50RIM 5009.5±INV. OUT 5006.75 (E)EXISTING
GROUND
PROPOSED
GROUND
PRIVATE
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 43
C 625PLAN & PROFILESTORM DRAINS 5 & 5-232
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
NORTH
( IN FEET )
1 inch = ft.
Feet05050
50
100 150
PROFILE SCALE:
STORM DRAIN 5
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
NOTES:
W
EXISTING SANITARY SEWER SS
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPOSED LOT LINE
PROJECT BOUNDARY
EXISTING RIGHT OF WAY
EXISTING STORM SEWER
EASEMENT LINE
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES.
3.PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND
STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF
FLARED END SECTIONS.
4.ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND
INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY CITY OF
FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE
R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE
'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443
FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE).
5.CONTRACTOR SHALL CONFIRM THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR
THEIR PROPOSED METHODS OF INSTALLATION (i.e., WITHIN PRE-CASTER'S
TOLERANCES, ETC.).
6.CONTRACTOR SHALL DEFLECT SERVICE LINES TO AVOID STORM DRAIN LINES.
PROPOSED RIGHT OF WAY
INLET SUMMARY TABLE
DESIGN
POINT
DESIGN INLET
LABEL INLET TYPE INLET SIZE
A2 INLET 2-5 Area Inlet 2' X 15'
B1 INLET 3-4 Nyoplast 30 in.30"
B2 INLET 1-3 Area Inlet 2' X 1.35'
B3 INLET 1-4 Area Inlet 2' X 1.35'
B6 INLET 1-9.5 Type R 5'
B7 INLET 1-9.1 Type R 5'
B9 INLET 1-5.1 Type R 5'
B10 INLET 1-6.3 Type R 5'
D3 INLET 6-2 Type R 5'
D5 INLET 4-4A Area Inlet 4' X 1.35'
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
STORM
DRAIN 5
STORM DRAIN 5-2
PROFILE SCALE:
STORM DRAIN 5-2
SEEEET
SWWW
WWS
SUD
UD
UD
UDGGEEGGG G G G GW
EE18" SSWW S TGGS SSFSF
F F
SF WF MHSS18" SS18" SS18" SS18" SS18" SS21" SS21" SS21" SS21" SSUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMHXX30" W30" W30" W30" WX
X
X
X
X
X
X
X
X
X
X
X X
X
30" W21" SS 21" SS
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
BB BBB
B
B
B
BB
B
BB
B
B
B
B
B
B BBBBB
B
B
B
BBB
B
B
B
B BBB
B BB
B
B
B
B
B BB
B BB
XXX
B
B BBB
B
B
B
B
X
X
X
X
X
X
PROPOSED 2'
CONCRETE PAN
CANAL IMPORT
A
T
I
O
N
STORM DRAIN 2
SEE SHEET C 623
STORM DRAIN 3
SEE SHEET C 623
EXISTING 30"
WATER SPRING CREEKSTORM DRAIN 5-2
SEE SHEET C 625
STORM DRAIN 5
SEE SHEET C 625
SANITARY LINE C
SEE SHEET C 612
PROPOSED 8"
PVC WATER
EXISTING 18"
SANITARY
EXISTING 21"
SANITARY
STORM DRAIN 1
SEE SHEET C 620
48'
SANITARY
SEWER
EASEMENT
WALL
E
N
B
E
R
G
D
R
47.44 LF 6" HDPE @ 0.20%
RG UD BASIN 2
STA 10+47.44
N: 1449016.23
E: 3114055.00
189.97 LF 4" HDPE @ 0.20%
RG UD CO 3
STA 12+37.41
N: 1449184.94
E: 3113981.90
RG UD PIPE END 1
STA 10+00.00
N: 1449029.22
E: 3114100.63
PROPOSED
RAIN GARDEN
BUILDING 14 BUILDING 13 BUILDING 12 BUILDING 11 BUILDING 10 BUILDING 9
4995
5000
5005
5010
5015
5020
5025
5030
4995
5000
5005
5010
5015
5020
5025
5030
9+5010+0011+0012+0013+00
EXISTING
GROUND
PROPOSED
GROUND RG UD PIPE END 1STA 10+00.00RIM 5006.5±INV. IN 5005.86 (W)47.44 LF
6" HDPE
@ 0.20%RG UD BASIN 2STA 10+47.44RIM 5010.4±INV. IN 5005.95 (NW)INV. OUT 5005.95 (E)189.97 LF
4" HDPE
@ 0.20%RG UD CO 3STA 12+37.41RIM 5008.6±INV. OUT 5006.33 (S)PROPOSED
SUBGRADEEGGGGGGFSVAULTELECWWEEEEEEEESSFDCIRGGGGT SH2OTRAFFICVAULTT SVAULTELECCONTROLIRRCONTROLIRRELECCONTROLIRRCONTROLIRREETGGGGEEEEEEEEEGGGG30" W30" W30" W30" W30" W36" W 36" W
36" WD/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /30" W30" W30" W30" W30" W30" WSTSTSTSTSSSSSSSSSSSSTORM DRAIN 4
SEE SHEET C 624STORM DRAIN 4-4B
SEE SHEET C 624
INLET 6-2
STA 11+07.91
N: 1448843.05
E: 3113202.86
107.91 LF 18" RCP @ 0.20%
FES 6-1
STA 10+00.00
N: 1448735.14
E: 3113201.88
S SHIELDS STREET
SANITARY LINE A
SEE SHEET C 610
BUILDING 1
5000
5005
5010
5015
5020
5025
5030
5035
5000
5005
5010
5015
5020
5025
5030
5035
9+5010+0011+0012+00 INLET 6-2STA 11+07.91RIM 5016.3±INV. OUT 5013.04 (S)107.91 LF 18" RCP @ 0.20%FES 6-1STA 10+00.00RIM 5015.2±INV. IN 5012.83 (N)EXISTING
GROUND
PROPOSED
GROUND
8" PVC WATER
STA.=10+80.89
TOP=5011.24
PRIVATE
100-YR
HGL
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 43
C 626PLAN & PROFILESTORM DRAIN 6 & UNDERDRAIN33
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
NORTH
( IN FEET )
1 inch = ft.
Feet05050
50
100 150
PROFILE SCALE:
UNDERDRAIN
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
NOTES:
W
EXISTING SANITARY SEWER SS
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPOSED LOT LINE
PROJECT BOUNDARY
EXISTING RIGHT OF WAY
EXISTING STORM SEWER
EASEMENT LINE
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES.
3.PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND
STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF
FLARED END SECTIONS.
4.ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND
INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY CITY OF
FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE
R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE
'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443
FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE).
5.CONTRACTOR SHALL CONFIRM THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR
THEIR PROPOSED METHODS OF INSTALLATION (i.e., WITHIN PRE-CASTER'S
TOLERANCES, ETC.).
6.CONTRACTOR SHALL DEFLECT SERVICE LINES TO AVOID STORM DRAIN LINES.
PROPOSED RIGHT OF WAY
INLET SUMMARY TABLE
DESIGN
POINT
DESIGN INLET
LABEL INLET TYPE INLET SIZE
A2 INLET 2-5 Area Inlet 2' X 15'
B1 INLET 3-4 Nyoplast 30 in.30"
B2 INLET 1-3 Area Inlet 2' X 1.35'
B3 INLET 1-4 Area Inlet 2' X 1.35'
B6 INLET 1-9.5 Type R 5'
B7 INLET 1-9.1 Type R 5'
B9 INLET 1-5.1 Type R 5'
B10 INLET 1-6.3 Type R 5'
D3 INLET 6-2 Type R 5'
D5 INLET 4-4A Area Inlet 4' X 1.35'
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
UNDERDRAIN
STORM DRAIN 6
PROFILE SCALE:
STORM
DRAIN 6
CABLE
F.O.
MH
TTTTTTTTTT5015 (NAVD88)
A
M
5
0
1
4
(
N
A
V
D
8
8
)5014
(NAVD88
)5013 (NAVD88)5011 (NAVD88)5010 (NAVD88)5008 (NAVD88)179
178
177
176
175
174
173
172171170169168
5010 (NAV
D
8
8
)
5011 (NAVD
8
8
)5012 (NAVD88)5013 (NAVD88)/ / / / / / / /SUDUDS
S
D
F.O.
MH
MM
MH
/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /STSTSTSTSTSTWINNE GRANT R/JOHNELLE S
1821 WALLENBERG DR
ERIKSEN CHRISTOPHER M
1825 WALLENBERG DR
MCCOY JOHN H/SHERRY P
1900 S SHIELDS ST
HILL POND CONDOMINIUMS
STA: 83 ELEV: 50
0
9
.
1
7
STA: 200 ELEV
:
5
0
0
9
.
5
7
STA: 319 EL
E
V
:
5
0
1
0
.
0
5
STA: 3
7
2
E
L
E
V
:
5
0
1
0
.
1
5
STA: 4
2
3
E
L
E
V:
5
0
1
0.
3
3
STA: 5
2
2
E
L
E
V
:
5
0
1
0.
6
2
STA: 720 EL
E
V
:
5
0
1
1
.
1
5
STA: 80
5
E
L
E
V
:
5
0
1
1
.
4
2STA: 905 ELEV: 5011.89STA: 983 ELEV: 5012.08STA: 1075 ELEV: 5012.31STA: 1136 ELEV: 5012.53SSSSSSSSSSSSSS/ / / / / / / /SUDUDh-a1
h-b2
h-b1
h-c1
h-d1
2.53 ac.
H-B1
1.01 ac.
H-A1
3.92 ac.
H-B2
0.74 ac.
H-C1
h-a20.16 ac.
H-A2
0.17 ac.
H-D1
os2
os3
1.80 ac.
OS2
0.47 ac.
OS3
0.44 ac.
H-B3
h-b3
h-c2
5.47 ac.
H-C2
3.38 ac.
H-E1
1.38 ac.
H-E2
h-e1
h-e2
0.48 ac.
OS1
os1
0.04 ac.
H-F1
h-f1
h-f2
0.18 ac.
H-F2
S SHIELDS ST.HOBBIT ST.WALLENBERG DR.FEMA 100-YR
HIGH RISK
FLOOD FRINGE
CITY OF FORT COLLINS
100-YR FLOODPLAIN
EXIST
I
N
G
S
P
R
I
N
G
C
R
E
E
K
T
R
A
I
L
SPRI
N
G
C
R
E
E
KEXISTING SIDEWALKEXISTING 8' TRAILCANAL IMPORTATIONWINNE GRANT
R/JOHNELLE S
1821 WALLENBERG
DR
ERIKSEN
CHRISTOPHER M
1825
WALLENBERG
DR
MCCOY JOHN H/SHERRY P
1900 S SHIELDS ST
HILL POND CONDOMINIUMS
FEMA XSEC #22186
5014.4 FT (NAVD 88)
FEMA 100-YR
FLOODWAY
CITY OF FORT
COLLINS 100-YR
FLOODWAY
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 43
LEGEND:
NORTH
( IN FEET )
0
1 INCH = 50 FEET
50 50 100 150
C 700EXHIBITHISTORIC DRAINAGE 34
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
INTERMILL LAND SURVEYING, INC.NORTHERN ENGINEERING SERVICES, INC.
COMPANY PROJECT NO. P-11-6963 COMPANY PROJECT NO. 838-016
DATE: APRIL 2011 DATE: JULY 2015
KING SURVEYORS
COMPANY PROJECT NO. 20190806
DATE: JANUARY 2020
PROJECT DATUM: NAVD88
BENCHMARK 29-92 APPROXIMATE 300 FEET SOUTH OF WEST PROSPECT ROAD AND
SHIELDS STREET, ON THE NORTH END OF THE WEST BRIDGE PARAPET WALL.
ELEVATION: 5025.67
BENCHMARK 28-92 SOUTHWEST CORNER OF WEST PROSPECT ROAD AND CENTER
AVENUE, ON A WATER VALVE PIT.
ELEVATION: 5010.65
PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM.
SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED DATUM (PRIOR
CITY OF FORT COLLINS DATUM) FOR THEIR VERTICAL DATUMS.
IF NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) IS REQUIRED
FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29
UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) = NAVD88 - 3.17'.
BASIS OF BEARINGS
WEST LINE OF THE NORTHWEST QUARTER OF SECTION 23 AS BEARING NORTH 00° 01'
50" EAST (ASSUMED BEARING), AND MONUMENTED AS SHOWN ON DRAWING.
PROPOSED CONTOUR
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROPOSED INLET
A
DESIGN POINT
FLOW ARROW
DRAINAGE BASIN LABEL
DRAINAGE BASIN BOUNDARY
PROPOSED SWALE SECTION
11
NOTES:
1.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION
2.ALL ELEVATIONS DEPICTED IN PLAN VIEW AND BENCHMARKS LISTED HEREON ARE
PER THE CITY OF FORT COLLINS VERTICAL CONTROL DATUM (NAVD 88).
3.NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE FLOODWAY,
WHETHER TEMPORARY (DURING CONSTRUCTION) OR PERMANENT. LANDSCAPING
SHALL ALSO MEET THE REQUIREMENTS FOR NO RISE IN THE FLOODWAY.
4.REFER TO THE FINAL DRAINAGE AND EROSION CONTROL REPORT FOR THE QUARRY
BY WATERMARK, DATED JULY 14, 2021 BY NORTHERN ENGINEERING FOR ADDITIONAL
INFORMATION.
5.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE CITYREGULATED, 100YEAR
CANAL IMPORTATION FLOODPLAIN/FLOODWAY AS WELL AS THE FEMA REGULATED
SPRING CREEK 100YEAR FLOODPLAIN/FLOODWAY. ANY DEVELOPMENT WITHIN THE
FLOODPLAIN MUST COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF CITY
MUNICIPAL CODE. THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM
THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE PERMIT FEES
PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES,
GRADING, FILL, DETENTION PONDS, BIKE PATHS, PARKING LOTS, UTILITIES,
LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE CITY OF FORT
COLLINS FLOODPLAIN LIMITS AS DELINEATED ON THE FINAL SUBDIVISION PLAT
6.ANY CONSTRUCTION ACTIVITIES, NONSTRUCTURAL DEVELOPMENT (BRIDGES,
SIDEWALKS, CULVERTS, VEGETATION, CURBCUTS, GRADING, ETC.) IN THE
REGULATORY FLOODWAY MUST BE PRECEDED BY A NORISE CERTIFICATION, WHICH
MUST BE PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF
COLORADO.
7.NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE FLOODWAY,
WHETHER TEMPORARY (DURING CONSTRUCTION) OR PERMANENT.
8.ANY PEDESTRIAN BRIDGES IN THE FLOODWAY THAT ARE NOT ABLE TO PASS THE 100
YEAR FLOW ARE REQUIRED TO BE “BREAKAWAY” AND TETHERED.
A
CROSS-SECTION (CSL)XS#: 2446
FIELD SURVEY BY:
CORRECTED EFFECTIVE BASE FLOOD
ELEVATION (BFE)
5003 (NAVD88)ELEVATION NAVD 88
BENCHMARK
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
FOR DRAINAGE REVIEW ONLY
NOT FOR CONSTRUCTION
CABLE
F.O.
T
MH
B M
TTTTTTA
M
AL179
178
177
176
175
174
173
172171170169168/ / / / / / / // / / / / / / /
W WWWSS
SSUDUDS
S
D
F.O.
D
MH
MM
MH
/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /STSTSTSTSSSSSSSSSSUDUDUD
FDC
FDC FDCFDCFDC FDC
FDC
FDC / / / / / / / // / / / / / / /
W WWWSS
SSUDUDBBBBBBBBBBBBB BBBBBBBBBBBBBBBBBBBBBBBBBBBBB BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBXXXXTRACT B
TRACT A
RAIN GARDEN A
EXISTING DRAINAGE
DITCH (DITCH C)
DETENTION
POND 2
100-YR WSEL =
5014.91
1.32 ac.
A1
0.98 ac.
D1
0.22 ac.
D2
0.61 ac.
B1
1.75 ac.
A2
0.70 ac.
B2
0.64 ac.
D7
0.48 ac.
B5
0.29 ac.
B4
0.21 ac.
B10
0.11 ac.
C1
0.16 ac.
C2
0.79 ac.
B7
0.47 ac.
OS3
3.38 ac.
E1
1.38 ac.
E2
0.48 ac.
OS1
1.80 ac.
OS2
0.18 ac.
F2
0.04 ac.
F1
d7
d1
a1
b1
b2
b4
b5
b6
b7
b3
c1
d2
os2
os3
e1
e2
os1
c2
CITY OF FORT COLLINS
100-YR FLOODWAY
S SHIELDS ST.HOBBIT ST.WALLENBERG DR.CITY OF FORT COLLINS
100-YR FLOODPLAIN
EXIST
I
N
G
S
P
R
I
N
G
C
R
E
E
K
T
R
A
I
L
SPRI
N
G
C
R
E
E
KEXISTING SIDEWALKCANAL IMPORTATIONWINNE GRANT R/JOHNELLE S
1821 WALLENBERG DR
ERIKSEN CHRISTOPHER M
1825 WALLENBERG DR
MCCOY JOHN H/SHERRY P
1900 S SHIELDS ST
HILL POND CONDOMINIUMS
f2
f1
PROPOSED
STORM DRAIN
PROPOSED
STORM DRAIN
PROPOSED
OUTFALL PIPE
PROPOSED
STORM DRAIN
PROPOSED OUTLET
STRUCTURE 5:15:15:15:112:1a2
PROPOSED
STORM DRAIN
DETENTION
POND 1
100-YR WSEL =
5011.37
1.05 ac.
D5
PROPOSED
STORM DRAIN
PROPOSED
STORM DRAIN 0.21 ac.
D3
0.77 ac.
D4
0.07 ac.
D6
d4
d3
d5
d6
PROPOSED OUTLET
STRUCTURE
PROPOSED
STORM
CHAMBERS
PROPOSED
STORM
CHAMBERS
FEMA XSEC #22186
5014.4 FT (NAVD 88)
FEMA 100-YR
FLOODWAY
CITY OF FORT
COLLINS 100-YR
FLOODWAY
PROPOSED
STORM DRAIN
PROPOSED
STORM DRAIN
BLDG 6 BLDG 7
BLDG 2
BLDG 3
BLDG 4 BLDG 5 BLDG 8
BLDG 18
BLDG 17
BLDG 16
BLDG 15
BLDG 14
BLDG 13
BLDG 12
BLDG 11
BLDG 10
BLDG 9
POND
OVERFLOW PATH
POND 2 OVERFLOW
CHANNEL TO POND 1 EXISTING 8' TRAILW PROSPECT RD.
W STUART ST.
BLDG 1
b8
0.43 ac.
B8
0.87 ac.
B6
FEMA 100-YR
HIGH RISK
FLOOD FRINGE
PROPOSED
STORM DRAIN
0.46 ac.
B9
b9
b10
2.31 ac.
B3
1
3
.
0
0
STORM 1
OVERFLOW PATH STORM 1
OVERFLOW PATH
STORM 1
OVERFLOW PATH
OVERTOPPING
WEIR B2
OVERTOPPING
WEIR B3
INLET 1-4
INLET 1-3
INLET 1-5.1
INLET 1-6.3
INLET 1-9.1
INLET 1-9.4
INLET 4-4A
INLET 6-2
INLET 2-3
SIDEWALK
CHASE D4
INTERMILL LAND SURVEYING, INC.NORTHERN ENGINEERING SERVICES, INC.
COMPANY PROJECT NO. P-11-6963 COMPANY PROJECT NO. 838-016
DATE: APRIL 2011 DATE: JULY 2015
KING SURVEYORS
COMPANY PROJECT NO. 20190806
DATE: JANUARY 2020
PROJECT DATUM: NAVD88
BENCHMARK 29-92 APPROXIMATE 300 FEET SOUTH OF WEST PROSPECT ROAD AND
SHIELDS STREET, ON THE NORTH END OF THE WEST BRIDGE PARAPET WALL.
ELEVATION: 5025.67
BENCHMARK 28-92 SOUTHWEST CORNER OF WEST PROSPECT ROAD AND CENTER
AVENUE, ON A WATER VALVE PIT.
ELEVATION: 5010.65
PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM.
SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED DATUM (PRIOR
CITY OF FORT COLLINS DATUM) FOR THEIR VERTICAL DATUMS.
IF NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) IS REQUIRED
FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29
UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) = NAVD88 - 3.17'.
BASIS OF BEARINGS
WEST LINE OF THE NORTHWEST QUARTER OF SECTION 23 AS BEARING NORTH 00° 01'
50" EAST (ASSUMED BEARING), AND MONUMENTED AS SHOWN ON DRAWING.
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 43
PROPOSED CONTOUR
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROPOSED INLET
A
DESIGN POINT
FLOW ARROW
DRAINAGE BASIN LABEL
DRAINAGE BASIN BOUNDARY
PROPOSED SWALE SECTION
11
NOTES:
A
LEGEND:
NORTH
( IN FEET )
0
1 INCH = 80 FEET
80 80 160 240
C 701DRAINAGE EXHIBIT35
KEYMAP
CABLE
F.O.
TE
MH
24" SS 24" SS 24" SS 24" SS
24" SS24" SS24" SS24" SS
24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS
EEE
EEEEEEEEE
EEEEE
EEEEE
EEEEE
EEEE
TT
T
T
T
T
T
TTTTTTTTTTTTTTTTTTTTTTT GW W W W W W W W W W W W W W W W W W W W W W W W W W
12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" W12" WEEEEEEEEEEEEEEEEEEEEE
GGGGGGGG
G
G
GG GGGGGGGGGX
X
XXXXX
X
X
XXX
XX
XX
XXXX
X
X
X
X
XXXXXXXX
X
X
X
X
XXX30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" W30" WUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDUDMH
/ / / / / / / // / / / / / / // / / / / / / /30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W XSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST
CROSS-SECTION (CSL)XS#: 2446
FIELD SURVEY BY:
CORRECTED EFFECTIVE BASE FLOOD
ELEVATION (BFE)
5003 (NAVD88)ELEVATION NAVD 88
BENCHMARK
1.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION
2.ALL ELEVATIONS DEPICTED IN PLAN VIEW AND BENCHMARKS LISTED HEREON ARE
PER THE CITY OF FORT COLLINS VERTICAL CONTROL DATUM (NAVD 88).
3.NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE FLOODWAY,
WHETHER TEMPORARY (DURING CONSTRUCTION) OR PERMANENT. LANDSCAPING
SHALL ALSO MEET THE REQUIREMENTS FOR NO RISE IN THE FLOODWAY.
4.REFER TO THE FINAL DRAINAGE AND EROSION CONTROL REPORT FOR THE QUARRY
BY WATERMARK, DATED JULY 14, 2021 BY NORTHERN ENGINEERING FOR ADDITIONAL
INFORMATION.
5.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE CITYREGULATED, 100YEAR
CANAL IMPORTATION FLOODPLAIN/FLOODWAY AS WELL AS THE FEMA REGULATED
SPRING CREEK 100YEAR FLOODPLAIN/FLOODWAY. ANY DEVELOPMENT WITHIN THE
FLOODPLAIN MUST COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF CITY
MUNICIPAL CODE. THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM
THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE PERMIT FEES
PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES,
GRADING, FILL, DETENTION PONDS, BIKE PATHS, PARKING LOTS, UTILITIES,
LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE CITY OF FORT
COLLINS FLOODPLAIN LIMITS AS DELINEATED ON THE FINAL SUBDIVISION PLAT
6.ANY CONSTRUCTION ACTIVITIES, NONSTRUCTURAL DEVELOPMENT (BRIDGES,
SIDEWALKS, CULVERTS, VEGETATION, CURBCUTS, GRADING, ETC.) IN THE
REGULATORY FLOODWAY MUST BE PRECEDED BY A NORISE CERTIFICATION, WHICH
MUST BE PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF
COLORADO.
7.NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE FLOODWAY,
WHETHER TEMPORARY (DURING CONSTRUCTION) OR PERMANENT.
8.ANY PEDESTRIAN BRIDGES IN THE FLOODWAY THAT ARE NOT ABLE TO PASS THE 100
YEAR FLOW ARE REQUIRED TO BE “BREAKAWAY” AND TETHERED.
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
FOR DRAINAGE REVIEW ONLY
NOT FOR CONSTRUCTION
LID Summary per LID Structure
LID ID
Area Weighted %
Impervious Subbasin ID Treatment Type Volume per
UD-BMP (ft3)
Vol. w/20%
Increase per Fort
Collins Manual
(ft3)
Impervious
Area (ft2)
Sq. Ft.Acres
Rain Garden A 318,413 7.31 71%B1 Rain Garden 5,621 6,745 225,001
Stormtech 1 76,238 1.75 77%A2 Stormtech 1,578 1,894 58,703
Stormtech 2 81,341 1.87 58%D5,6,7 Stormtech 1,247 1,496 47,552
Total 475,992 10.93 10,135 331,257
Rational Flow Summary | Developed Basin Flow Rates
BASIN
TOTAL
AREA
(acres)
Tc2
(min)
Tc100
(min)
C2 C100 Q2
(cfs)
Q100
(cfs)
A1 1.32 5.0 5.0 0.27 0.34 1.02 4.47
A2 1.75 5.0 5.0 0.79 0.99 3.94 17.24
B1 0.61 10.7 10.7 0.48 0.60 0.64 2.78
B2 0.70 5.0 5.0 0.69 0.86 1.37 5.95
B3 2.31 5.0 5.0 0.92 1.00 6.07 23.03
B4 0.24 5.0 5.0 1.00 1.00 0.70 2.43
B5 0.48 5.0 5.0 0.65 0.82 0.89 3.92
B6 0.87 5.0 5.0 0.95 1.00 2.35 8.64
B7 0.84 5.0 5.0 0.86 1.00 2.05 8.32
B8 0.43 5.0 5.0 0.75 0.93 0.91 3.94
B9 0.46 5.0 5.0 0.95 1.00 1.24 4.57
B10 0.21 5.2 5.2 0.49 0.61 0.29 1.25
C1 0.11 5.0 5.0 0.25 0.31 0.08 0.33
C2 0.16 5.0 5.0 0.63 0.78 0.29 1.26
D1 0.98 5.0 5.0 0.29 0.37 0.81 3.60
D2 0.22 10.6 10.6 0.25 0.31 0.12 0.51
D3 0.21 5.0 5.0 0.85 1.00 0.52 2.13
D4 0.77 5.0 5.0 0.92 1.00 2.01 7.64
D5 1.05 5.0 5.0 0.91 1.00 2.73 10.49
D6 0.07 5.0 5.0 0.68 0.85 0.13 0.58
D7 0.64 6.1 6.1 0.36 0.45 0.61 2.68
E1 3.38 12.8 12.8 0.16 0.19 1.09 4.53
E2 1.38 8.8 8.8 0.11 0.14 0.36 1.59
F1 0.05 5.0 5.0 0.72 0.90 0.09 0.40
F2 0.18 7.3 7.3 0.62 0.78 0.28 1.21
OS1 0.48 5.0 5.0 0.84 1.00 1.16 4.82
OS2 1.80 9.3 9.3 0.91 1.00 3.77 14.45
OS3 0.87 5.0 5.0 0.86 1.00 2.14 8.69
LID Site Summary - New Impervious Area
Total Area of Current Development 642,773 ft2
Total Impervious Area 385,987 ft2
Total Impervious Area without LID Treatment 51,223 ft2
A1,C,D1-4,E,F
75% Requried Minium Area to be Treated 289,490
Total Treated Area 331,257 ft2
Percent Impervious Treated by LID 85.82%
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 43
C 800WATER DETAILS36
100 TYPICAL WATER MAIN
106 TYPICAL WATER SERVICE
107 TYPICAL SETTING FOR 1-1/2 IN. AND 2 IN.
WATER METERS
103 TYPICAL SETTING FOR 1-1/2 IN. AND 2 IN.
WATER METERS
102 TYPICAL MAIN LOWERING ANCHOR BLOCKS
101 TYPICAL FIRE HYDRANT
105 TYPICAL WATER MAIN LOWERING
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
6"6"6"6"6"6"6"6"6"6"6"6"6"6"6"6"6"6"6"6"STREET STREET6"
104 TYPICAL TRACER WIRE
200 CONCRETE THRUST BLOCKS
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 43
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
C 801WATER DETAILS37
201 TRAFFIC-RATED CURB STOP INSTALLATION 202 3
4 IN. AND 1 IN. WATER METER 203 3
4 IN. AND 1 IN. WATER METER
303
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 43
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
C 802SANITARY SEWER DETAILS38
TRAFFIC RATED CLEANOUT300TYPICAL WASTEWATER BEDDING
301 TYPICAL MANHOLE (WASTEWATER)
COMPACTED GRANULAR MATERIAL
CONFORMING TO CDDH #67
LOWER LIMIT OF
TRENCH WALL
SLOPING
INITIAL LIFT *
12 IN. MIN.
PIPE O.D.
4 IN. MIN.
TRENCH WIDTH AS SPECIFIED
IN SECTION 02221
COMPACTED GRANULAR MATERIAL
CONFORMING TO CDDH #67
*
BEDDING REQUIRMENTS
WW-1
ALTERNATE BASE
POURED INVERT
PRECAST MANHOLE BASE2 IN. MIN.SLOPE
1 IN. MIN.
8 IN. MIN.
6 IN.
15 IN. OR LESS 48 IN.
60 IN.18 IN. TO 30 IN.
72 IN.OVER 30 INCHES
MIN. MANHOLE
MINIMUM INSIDE DIAMETER OF
DIAMETER
MANHOLE SHALL BE AS FOLLOWS:
PIPE SIZE5 FT. MIN. DEPTHCONCRETE ADJUSTMENT SHIMS
GROUTED INSIDE
ASTM C-478 ECCENTRIC CONE
PRE-FORMED PLASTIC GASKET
ASTM C-478 MANHOLE SECTIONS
GROUT BASE TO BARREL
SECTION ON INSIDE
PRE-FORMED PLASTIC GASKET
CAST-IN-PLACE CONCRETE BASE
16 IN. MAX.
FINISHED GRADE
30 IN. MIN.48 IN. MAX.VARIABLE28 IN. MAX.
24 IN.
SEE TABLE
6 IN.
12 IN.
SLOPE
1 IN./FT.
18 IN.
MAX.
MANHOLE RUNGS
12 IN. O.C.
8 IN. MIN
STANDARD MANHOLE
WW-3
302 TYPICAL SANITARY SERVICE
PLAN VIEW
CROSS VIEW
45 ELBOW
SERVICE WYE
8 IN. PVC SEWER PIPE
COMPACTED GRANULAR MATERIAL
AIR-TIGHT PLUG WITH
4 IN. X 4 IN. MARKER
UNYIELDING PIPE BEDDING
OF COMPACTED ROCK OR
LEAN CONCRETE
PVC SEWER PIPE
NOTE: WYE CONNECTION NOT
ALLOWED ON VCP
LEAN CONCRETE
o
20 MIN.o
45 MAX.o
TRENCH
UNYIELDING PIPE BEDDING
OF COMPACTED ROCK OR
4 IN. X 4 IN.
MARKER
AIR-TIGHT PLUG
SERVICE WYE DETAIL
WW-9
FLOW DIRECTION
TRAFFIC RATED CLEANOUT
WW-15
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 43
C 803DRAINAGE DETAILS39
400 TYPICAL STORMWATER BEDDING
401 TYPICAL MANHOLE (STORM)
404 TYPICAL MANHOLE CHANNELING (STORM)
o
402 TYPICAL SHALLOW MANHOLE WITH
FLAT TOP
407 TYPICAL 4-FT. CURB INLET
REINFORCEMENT
401
402
403
404
405
406
407
408
501
502
503
504
8 8.5
8 IN.
12 IN.
9 IN.
6 IN.
24 IN.
9 IN.
9 IN.
12 IN.
12 IN.
12 IN.
12 IN.
12 IN.
12 IN.
601
5/8 IN.
5/8 IN.
5/8 IN.
5/8 IN.
3/4 IN.
1/2 IN.
1/2 IN.
TABLE 1
BAR LIST FOR CURB INLET
-
II
VIII
II
VII
II
II
II
II
II
IV
II
III
2
1
2
1
4
2
2
4
*
14
6
4
*
1 FT. 6 IN.
4 FT. 8 IN.
4 FT. 8 IN.
9 FT. 0 IN.
3 FT. 4 IN.
9 FT. 0 IN.
9 FT. 0 IN.
*
3 FT. 2 IN.
*
7 FT. 4 IN.
3 FT. 10 IN.
7 FT. 10 IN.
-
MARK DIA.O.C.TYPE NO.LENGHTIN.REQ'DSPACING
ANCHOR
8 FT. 10 IN.
5 FT. 0 IN.-
-1
1-
-
*VARIBLE WITH HIGHT, REFER TO TABLE 2.
11 FT.
3 FT.5 FT.3 FT.
8 8.5 WITH 1 1/2 IN.
DIA. HOLE IN CENTER2 FT.
4 FT. 6 IN.
8 IN. O.C.
9 IN. O.C.
6 IN. O.C.12 IN.12 IN.
ANCHOR
BACK OF CURB
FLOW LINE
503
504
502
501
401
601
407
407
408
ANCHOR 601
2 FT.4 FT. - 6 IN.
601
501
ADD 1
#4 BAR
(402)
404
504
503
ADD 1
#4 BAR(402)
402 406
12 IN. LAP
402 403
402
#4 BAR
3 IN CIR.
OUT
SI
D
E
PIPE
DIA.
SECTION A-A
408
2 FT.5 FT.2 FT.1 FT.1 FT.
#4 ANCHORS402
404
405
402
405402
403
SECTION B-B
A
B
A
B
PLAN VIEW
NTS
3 FT. 6 IN.
4 FT. 0 IN.
4 FT. 6 IN.
5 FT. 0 IN.
5 FT. 6 IN.
6 FT. 0 IN.
6 FT. 6 IN.
7 FT. 0 IN.
7 FT. 6 IN.
8 FT. 6 IN.
8 FT. 6 IN.
9 FT. 0 IN.
9 FT. 6 IN.
10 FT. 0 IN.
TYPE IV
TYPE VII
TYPE VIII
TYPE III
"U"
"U"
BENT
LOOP
20 IN.
20 IN.
54 IN.
48 IN.
8 IN.
11 IN.
30 IN.
12 IN.
LAP
LENGHT
STRAIGHT
TYPE II
LENGHT
402 405 404 406 CONC.STEEL
LB.C.Y.
3 FT. 2 IN.
3 FT. 8 IN.
4 FT. 2 IN.
4 FT. 8 IN.
5 FT. 2 IN.
5 FT. 8 IN.
6 FT. 2 IN.
6 FT. 8 IN.
7 FT. 2 IN.
7 FT. 8 IN.
8 FT. 2 IN.
8 FT. 8 IN.
9 FT. 2 IN.
9 FT. 8 IN.
2 FT. 1 IN.
2 FT. 7 IN.
10
12
12
14
14
16
16
18
18
20
20
22
22
24 24
18
22
16
16
14
14
12
12
10
10
8
8
6 6
8
8
10
10
12
12
14
14
16
16
22
18
2424
22
22
20
20
18
18
16
16
14
14
12
12
10
3 FT. 1 IN.
3 FT. 7 IN.
4 FT. 1 IN.
4 FT. 7 IN.
5 FT. 1 IN.
5 FT. 7 IN.
6 FT. 1 IN.
6 FT. 7 IN.
7 FT. 1 IN.
7 FT. 7 IN.
8 FT. 1 IN.
8 FT. 7 IN.
H
QUANITIES VARIBLES WITH HEIGHT
TABLE 2
BAR BENDING DIAGRAM
(DIMENSION ARE OUT TO OUT OF BAR)GENERAL NOTES:
1. QUANTITIES INCLUD VOLUMES OCCUPIED BY PIPES.
STRUCTURAL STEEL REINFORCEMENT AROUND
PIPES ARE NOT INCLUDED.
2. KEY JOINTS WHERE WALSS CONNECT TO TOP
SLAB AND BASE.
3. REINFORCEMENT IN WALLS AND BASE SHALL BE
3 IN. FROM THE SIDES EXPOSED TO EARTH.
REINFORCEMENT IN TOP SLAB SHALL BE 1 1/2 IN CLEAR.
29 I
N
.
NTS
NTS
405 TYPICAL CURB, GUTTER, AND SIDEWALK
406 TYPICAL 4-FT. CURB INLET
A
A
B B
SECTION A-A
DETAIL "A"
SECTION B-B
CURB FACE ASSEMBLY DETAIL
GENERAL NOTES
PLAN VIEW
6 IN. STEEL DECK RING WITH
24 IN. HEAVY DENVER COVER BY
MACLEAR OR APPROVED EQUAL.
6 IN. THICK
SIDEWALL (TYP.
BOTH SIDES)
3 FT.5 FT.3 FT.
6 IN.6 IN.
BACK OF
CURB
FLOW LINESEE DETAIL "A"
4 FT. OPENING
WARPED CURB &
GUTTER (TYP.
BOTH SIDES)
6 IN.
3 FT.-6 IN.
6 IN.
2 FT.
11 FT.
6 IN.
2 FT.4 FT.- 6 IN.
6 IN.
SEE CURB FACE
ASSEMBLY DETAIL
MANHOLE
RUNGS-12 IN. O.C.
1% SLOPE FOR
DRAINAGE
6 IN.
3 FT.-6 IN.4 FT.
WARPED
GUTTER
DEPRESSED GUTTER
NORMAL FLOW LINE
TOP OF GUTTER
ALTERED
FLOW LINE
6 IN.6 IN.
1% SLOPE FOR
DRAINAGE
6 IN.
WALL
3 IN.
RAD.6 IN.
EXTEND CHANNEL
TO OUTSIDE
EDGE OF WALL
10 IN.
EMBEDMENT
8 8.5 FLUSH
WITH CURB FACE
NTS
1 1/2 IN. R
#4 BAR
18 IN. LONG
2 IN.
2 IN.4:16 IN.
MAX/MIN.
8 IN.
2:1 #5 BAR
6 IN.
1 1/2 IN. PIPE SPACER
AND 1 1/4 IN. LOCK NUT
4 IN.
1/4 IN.
1 1/4 IN. DIA. X 24 IN. GALV.
3 1/2 IN. AT TOP.
3 IN. X 3 IN. X 3/8 IN.
PLATE
6 IN.
1/4 IN.-1 IN. LEG
WARPED
GUTTER
VARIABLEMAX. HEIGHT-10 FT.2 FT. -6 IN. MIN.(UNLESS SQUASH PIPEIS USED)STEEL ROD - THREADED
3 FT.-6 IN.
6 IN.
1. SEE D-7B FOR REINFORCEMENT.
2. FLOOR OF INLET SHALL BE SHAPED WITH
ADDITION CONCRETE TO FORM INVERT
TO PIPE CONNECTIONS.
3. MANHOLE RUNGS SHALL BE REQUIRED FOR
INLET HEIGHT 4 FT. AND GREATER.
4. SIDEWALK SHALL BE 6 IN. THICK FOR 3 FT.
ON EITHER SIDE OF INLET.
5. TOP SLAB OF INLET SHALL BE SLOPE TO
MATCH SIDEWALK. SEE D-6.
6. EXPOSED STEEL SHALL BE GALVANIZED IN
ACCORDANCE WITH AASHTO M-111.
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
403 AREA INLET
503 TYPICAL SIDEWALK CULVERT FOR DETACHED WALK - INFALL TO SITE
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 43
C 804DRAINAGE DETAILS40
500 TYPICAL AREA INLET
501 TYPICAL CULVERT, ATTACHED SIDEWALK
DETAIL "A"
PLAN VIEW
505 TYPICAL FLARED END SECTIONS
E
C B
E
E
C
D
PLAN
502 TYPICAL SIDEWALK CULVERT FOR DETACHED WALK - OUTFALL TO CURB
BACK OF CURB
EDGE OF STREET
5 8" GALV. STEEL PLATE
2
1
2
1
3"x2"x3 8" GALV. ANGLE
SEE DETAIL 1
#4@12"
O.C.
#4@12"
O.C.
#4@12"
O.C.
3"x2"x3 8"
GALV. ANGLE
5 8" GALV.
STEEL PLATE
#3 REBAR
ANCHOR
18 O.C.
3 8" BRASS SCREW
18 O.C. WITH
COUNTERSUNK HEAD
FLUSH WITH PLATE6"6"VARIES
2'
3'
SECTION B-B
DETAIL 1
SECTION A-A
PLAN
SECTION C-C
SLOPE
VARIES 0.5% SLOPE (MIN.)
VARIES VARIES
2' DEPRESSED GUTTER
VARIESEXPANSION
MATERIAL
5 8" GALV.
STEEL
PLATE
EDGE OF
STREET
12" R 12" R
2' OPENING 3'-3"3'-3"6" (TYP.)BACK
OF
CURB
3" (TYP.)
3' (TYP.)
SIDEWALK
(TYP.)
EXTEND WALK 6" ON
BOTH SIDES OF WALKVARIES
VARIESSLOPECC
BB
A
A
8'-6"
EXPANSION
MATERIAL
3 8" BRASS SCREW 18" O.C.
WITH COUNTERSINK
HEAD FLUSH WITH PLATE2'6"
504 TYPICAL STREET CROSS PAN
GENERAL NOTES:
1. 6 IN. X 6 IN. X 10/10 WWF SHALL BE INSTALLED
IN RADIUS AND PAN.
2. MINIMUM 6 IN. WIDE PAN FOR RESIDENTIAL
STREET.
3. MINIMUM 10 FT. WIDE PAN FOR ARTERIAL AND
COLLECTOR STREETS.
EXPANSION
MATERIAL
5 8" GALV.
STEEL
PLATE
EDGE OF
STREET
12" R 12" R
2' OPENING 3'-3.0000"3'-3.0000"
6.0000" (TYP.)
BACK
OF
CURB
SLOPE PLATE TO
MATCH SIDEWALK
BACK OF CURB
EDGE OF STREET
5 8" GALV. STEEL PLATE
2
1
2
1
3"x2"x3 8" GALV. ANGLE
SEE DETAIL 1
#4@12"
O.C.
#4@12"
O.C.
#4@12"
O.C.
3"x2"x3 8"
GALV. ANGLE
5 8" GALV.
STEEL PLATE
#3 REBAR
ANCHOR
18 O.C.
3 8" BRASS SCREW
18 O.C. WITH
COUNTERSUNK HEAD
FLUSH WITH PLATE
6.0000"
VARIES
2'
3'
SECTION B-B
DETAIL 1
SECTION A-A
PLAN
SECTION C-C
SLOPE
VARIES 0.5% SLOPE (MIN.)
3.0000" (TYP.)
3' (TYP.)
SIDEWALK
(TYP.)
EXTEND WALK 6" ON
BOTH SIDES OF WALK
VARIES
VARIES
SLOPECC
BB
A
A
2' DEPRESSED GUTTER
VARIES
8'-6.0000"
EXPANSION
MATERIAL
3 8" BRASS SCREW 18" O.C.
WITH COUNTERSINK
HEAD FLUSH WITH PLATE 1'-11.9831"1.9658" MIN.
VARIES VARIES
2'
6.0000"
5.9991"
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
C 805DRAINAGE DETAILS41
600 TYPICAL CONCRETE PAN
602 TYPICAL CONCRETE FOREBAY
601 CURB INLET
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 43
A A
SECTION A-A
PLAN VIEW
DIRECTION OF FLOW
PROPOSED NATIVE
MATERIAL SUBBASE
FLOWLINE OF NOTCH
FINISH GROUND
6"
W
6.0"
DIRECTION OF FLOW
NOTE:
1.SEE GRADING PLAN FOR ELEVATIONS AND
SLOPES.
2" NOTCH
6" TYP.
REV C7001-110-042DWG NO.1 OF 1SHEET1:40SCALEDWG SIZE A
3130 VERONA AVE
BUFORD, GA 30518
PHN (770) 932-2443
FAX (770) 932-2490
www.nyloplast-us.com
8 IN - 30 IN TYPICAL INSTALLATION OPTIONS
TITLE
PROJECT NO./NAME
MATERIAL
DATE
APPD BY
8-10-00DATE
AWADRAWN BYTHIS PRINT DISCLOSES SUBJECT MATTER IN WHICH
NYLOPLAST HAS PROPRIETARY RIGHTS. THE RECEIPT
OR POSSESSION OF THIS PRINT DOES NOT CONFER,
TRANSFER, OR LICENSE THE USE OF THE DESIGN OR
TECHNICAL INFORMATION SHOWN HEREIN
REPRODUCTION OF THIS PRINT OR ANY INFORMATION
CONTAINED HEREIN, OR MANUFACTURE OF ANY
ARTICLE HEREFROM, FOR THE DISCLOSURE TO OTHERS
IS FORBIDDEN, EXCEPT BY SPECIFIC WRITTEN
PERMISSION FROM NYLOPLAST.
8-10-00
CJA DUCTILE IRONDO NOT POLLUTE DRAINS TO WATERWAYSNYLOPLASTTSALPOLYN
DUC
TI L E IR O N
TSALPOLYNDUCTILEIRONDUCTILE IRONDO NOT POLLUTE DRAINS TO WATERWAYSNYLOPLASTWHEN ARE DRAIN BASINS USED?
2808AG _ _ X
2810AG _ _ X
2812AG _ _ X
2815AG _ _ X
2818AG _ _ X
2824AG _ _ X
2830AG _ _ X
WHEN ARE INLINE DRAINS USED?
2708AG _ _ X
2710AG _ _ X
2712AG _ _ X
2715AG _ _ X
2718AG _ _ X
2724AG _ _ X
2730AG _ _ X
TYPICAL INSTALLATIONS
TYPICAL INSTALLATION OF NYLOPLAST
DRAIN BASIN AND INLINE DRAIN
1: TO ENTER AN EXISTING LINE
USING A TEE & RISER
2: AT THE BEGINNING OF A DRAIN LINE
USING AN ELBOW & RISER
TEE ELBOW
12" DRAIN BASIN
2 INLET & OUTLET
ADAPTERS CAN BE
PUT ON ANY ANGLE
1: TO CHANGE ELEVATION 2: TO CHANGE PIPE DIAMETER 3: TO CHANGE PIPE TYPE 4: FOR SHALLOW
APPLICATIONS 5: TO CHANGE DIRECTION
A°
RISER
DRAIN BASIN
INLINE DRAIN
10" INLINE DRAIN
10" INLINE DRAIN
3 VARIABLE ELEVATION
WATERTIGHT ADAPTERS AVAILABLE
FOR MOST COMMON PLASTIC PIPING SYSTEMS
8"6"
CORRUGATED
HDPE PIPE SMOOTH WALL
PVC
1 - STRUCTURES & ADAPTERS AVAILABLE IN SIZES 8" - 30"
2 - ADAPTERS CAN BE MOUNTED ON ANY ANGLE 0° TO 360°, TO DETERMINE
MINIMUM ANGLE BETWEEN ADAPTERS SEE DRAWING NO. 7001-110-012,
7001-110-013, & 7001-110-014
3 - DRAIN BASIN TO BE CUSTOM MANUFACTURED ACCORDING TO PLAN DETAILS
RISERS ARE NEEDED FOR BASINS OVER 84" DUE TO SHIPPING RESTRICTIONS
SEE DRAWING NO. 7001-110-065
CAD FILE NAME:
DRAWN BY:T. COX
D46.dwg
8/15/05DATE DRAWN:
CC
A
A
B
B
3'-6"Ls1'
6"Ws6"6"VARIESVARIES6"Ws/2Ws/2SECTION C-C
SECTION A-A SECTION B-B
WELL SCREEN FLOW CONTROL PLATE
2'-6"6"WoWo
Wo
Wp
4"(TYP.)1'(MAX.)PLAN
6"3"CLR.D1
GENERAL NOTES
SECTION D-D
WQD
D
A A
OPP.
CLR.
ABBREVIATIONS
@
#
Wp
Wo
TYP.
DIA.
O.C.
MAX.
MIN.
LEGEND
WQINV.
ELEV.6"6"Ls
Ws
DETAIL
LAST DATE REVISED:4/7/11
POND 1 POND 2
ELEV A 5011.60 5015.40
ELEV B 5008.75 5012.95
ELEV C 5009.75 5013.925
D wq (FT)N/A 1.60
LS (FT)4.00 4.00
WS (FT)4.00 4.00
WO (FT)N/A 1.00
HOLE DIA (INCH)N/A 13/16
# ROWS N/A 5
# COLUMNS N/A 1
100-YEAR ORIFICE DIA (INCH)4 9 3/4
604 OUTLET STRUCTURE
AA
B
B
A A
DATE DRAWN:3/3/05
D43.dwg
T. COXDRAWN BY:
CAD FILE NAME:
DETAIL
603 TYPICAL BASIN INSTALLATION
700 TYPICAL CURB AND GUTTER
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 43
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
C 806SITE DETAILS426"2"R.2"6"6"12"1 1/2"R.
2'-6"
6"
4 1/2"
30"
9"
R 0.5"
4.5"
18"
3.63"
21.75"
R 0.13"
7"
2"
3.75"
12"
ROLL-OVER
VERTICAL
(LOVELAND)
Gutter edge may be
tapered or battered.
(Typical for all Curb &
& Gutter Types)7 3/8" (L)1 3/8"17"6"3 3/8"14"
FL
R 16"R 16"DRIVE-OVER CURB, GUTTER AND DETACHED SIDEWALK
31"
See Drawing 1601
10 3/4"(L)R 16"DRIVE-OVER CURB, GUTTER AND ATTACHED SIDEWALK
18"18"3 3/8"1 3/8"6"R 16"FL
14"6"17"
1 1/2"
5' (L)8 5/8" (F.C.)7 1/4" F.C.12" (F.C.)Slope to curb 1/4"/Ft.
1' min. (F.C.)
48:1 min.
4:1 max.
Excavation
Fill
1' min.
2' min.
1/4"/Ft.
CURB & GUTTER IN A CUT OR FILL
6"3'-9" (F.C.)
For Thickness
2' min. (L)
701 TYPICAL DRIVE-OVER CURB AND GUTTER AND SIDEWALK
702 TYPICAL MEDIAN ISLAND CURBS
6"1"1 1/2"R.
1'-6"
2" R.
4-1/2"12"6"OUT FALL CURB & GUTTER
8" BARRIER CURB
6"1'-0"a.) Bottom of curb shall be poured to a depth no less than on the compacted subgrade of the pavement.
6"6"6"1'-6"18"10"8"ROADWAY
PAVEMENT
FL LF
6" MOUNTABLE CURB
1 1/4"
BARRIER CURB (KEY WAY OR EPOXY)
1/8" TO 1/4"R.
1"± 1/4"
CONCRETE PAVEMENT
(SECTION B)
1 1/2"3"ASPHALT OR
6"
1 1/2"R.
1 1/2"
(SECTION M)
MOUNTABLE CURB (KEY WAY OR EPOXY)
3 1/2"3"
1"± 1/4"
1"R.
6"4"
1/8" TO 1/4"R.
6" w/concrete pavement
8" w/asphalt
*
*
6"
1-1/2"
b.) Raised center medians shall be 8" barrier curb or 8" epoxy curb only.
Notes:REVEAL(CDOT TYPE 2 SECTION B M-609-1 CURB W/8" REVEAL)6"(FORT COLLINS ONLY)
1-1/2" TO
Final asphalt lift,
overlay or grade
adjustment
Depress ring 1/4" to 5/8" below
adjacent finished street grade
Slope up to match
finished pavement
Straight cut
around ring
Concrete grade ring
to match slope or
finished grade
Grade ring
Existing base course
Manhole
Shim / Grout 16" max.NOTE:
1. Grout shall be a mixture of 100 lbs Grout mix, 26 lbs
water (3.12 Gal), and 100 lbs of sand conforming to ASTM C-35.
2. Manholes shall not be located in crosspans, gutters, or wheel path.
3. Shim and grout to make ring and cover flush with the finished
pavement surface.
Cover
Support with Steel Shims
and pack with High Strength
Grout
703 TYPICAL MANHOLE COVER
706 TYPICAL PAVEMENT MARKINGS
WITH TURN LANE
704 TYPICAL SIGN POST
705 TYPICAL PAVEMENT MARKINGS
Max. Sign Panel
1. Attach the sign panels tightly to the post and use oversized washers to keep the sign from breaking loose
from the post when hit by a vehicle.
2. Sign panels should be mounted a minimum of 7 feet above the pavement or ground.
Cross section of post
3" - 6" ABOVE GRADE
2 1/4" Anchor
3. Signs larger than 36 inches in length or width require wind bracing and special post design.
NOTES:
4. Anchor Stub and post are square steel tube (perforated).
Anchor/Stub Post Size
CRITERIA FOR SINGLE POST
36" x 36"2.25" x 2.25" x 3'-0"2" x 2" x 12'-0"
5. All "No Parking" signs shall be installed at 45° from Flow Line.
**
2" x 2" x 10' OR 12'
12 GAUGE TELESPAR POST
(22F12A31)7'-0" MIN. CLEARANCE2' - 3'
FROM F
Street Curb
See Figure 16-1
SW SAMPLEAVE
2400
R1-1 "STOP" SIGN 30" HIGH DENSITY/DIAMOND
GRADE. SIGN MOUNTED TO POST WITH 1 EACH
DRIVE RIVET WITH NYLON WASHER AGAINST SIGN
FACE (ON TOP OF THE SIGN). THE BOTTOM OF THE
SIGN SHALL BE MOUNTED WITH 1 EACH
5/16"x2-1/2" HEW BOLT WITH METAL AND FROM
NYLON WASHERS (NYLON WASHER AGAINST SIGN
FACE) AND SECURED WITH 1 EACH 5/16" HEX NUT
ON THE BACK SIDE OF POST.L
2-1/4" x 2-1/4" x 3'
ANCHOR/STUB
2 EACH 8" BLADES
MOUNTED TO POST
WITH 4 EACH DRIVE
RIVETS WITH
NYLON WASHERS
*12 Gauge 30"8"8"Double Lines
Normal Width Line
4" White
4" Yellow
4" Space
4" White
Preferential lane symbol
(6' X 4') for designated
bikeways. White pavement
marking placed 65' (min) from
the projected flowline and
Projected Flowline (FL)NO CROSSPAN
Continental bars (9' X 1.5'):NO CROSSPAN OR EXISTING CROSSPANWhite Stop Bar (1.5' X Length)
30' Gaps
3:1 Ratio
10' Segments
4" White
Broken Line STANDARDNO STOP BAR SPECIFIEDSTOP BAR SPECIFIED
STOP BAR SPECIFIED
EXISTING CROSSPAN
Crosspan exits (no stop bar) -- shall
No crosspan -- shall be positioned
along projected flowline.
match the edge of the pan.
Crosspan exits (stop bar specified) --
shall be positioned along projected
flowline overlapping 4' of crosspan.12
3
CROSSWALK MARKINGS
FL to stop bar
14.5' Projected
14.5' Stop
Bar to FL 13'9'1.5'
6' Crosspan
4'
4'
4'
NOTES:
Continental crosswalk bars shall be placed
centered on each lane line & in the center of
each lane. (Lanes 5' wide or less shall not
receive a bar centered in the lane.) Both outside
Continental bars shall be centered on the curb &
gutter when possible.
If 6' crosspan exists, bars to
match pan edge to 13' from
projected FL.
Exception: The downstream bike lane line shall
terminate at the curb return.
NOTE:
All longitudinal (lane) striping shall terminate at the
continental crosswalk bars when no stop bar exists.
If a stop bar is specified, the striping shall terminate
at the stop bar.
65' (min)
centered on bike lane.
PAVEMENT MARKINGS
Projected Flowline (FL)
Broken line 4" white
10' Segments
30' Gaps
(3:1 Ratio)
Wide Lane
1.5'x9'
8" White
Line 4" white
Double Line
4" Yellow
4" Space
CROSSWALK MARKINGS:
STRIPING:
PREFERENTIAL LANE SYMBOL:
STOP LINES:
MANDATORY MOVEMENT:
1.5'x9
100' Taper (min.).2L L = Turn Bay Storage Length.4L
10'
.4L
10'
4" Ywllow
4" White Extension Line
An Engineering study should be required before crosswalk markings are installed in locations away
from traffic signals or stop signs. Continental crosswalk bars (1.5' x 9' typ.) shall be placed adjacent
to the projected flowline or abutting to existing crosspan. A bar shall be placed centered on each
lane line and in the center of each lane. Lanes 5' wide or less shall not receive a bar centered in
the lane. It is important that the markings are in alignment with the access ramps / sidewalks.
On curves:
Dotted extension of lane edge with same
as solid downstream line, 2' segments, 4'
gaps.
Mandatory movement lanes shall
use a lane-use arrow marking, the
word marking "only", another
lane-use arrow marking
(accompanied by signs). Symbols
& words are 8' of more in height --
use CDOT specification sizes.
Place stop lines (1.5' x Variable typ.)
only when inportant to indicate the
point behind which vehicles are
required to stop (more often on main
arterials) -- placement should
ordinarily be 4' in advance of and
parallel to the nearest crosswalk line
in the absence of a marked
crosswalk, the stop line should be
placed at the desired stopping point
no more than 30' or less than 4' from
the nearest edge of the intersecting
roadway.PLS shall be used for designated
bikeways. Intersection placement
-- the symbol shall be placed
downstream to convey to turning
traffic that the bike lane exists. It
shall be placed 4" down from the
PCR & centered on the bike lane.
Frequency of placement between
blocks is a matter for Engineering
judgement.
All Longitudinal (lane) striping shall
terminate at the Continental crosswalk
bars -- except the downstream bike
lane which shall terminate at the curb
return. If a stop line is in place --
upstream stripping shall terminate at
the stop line.
Not Required with lane
lengths less than 100'.
Not Required with lane
lengths less than 100'.
8" White Line
8" White Extension Line8" White
Extension
4" White Line
65' (min)
4'
C 807SITE DETAILS43
800 TYPICAL BICYCLE LANE
PAVEMENT MARKINGS
804 TYPICAL ADA HANDICAP PARKING
REQUIREMENTS
801 TYPICAL STREET NAME SIGN
805 TYPICAL ACCESS RAMPS -
RESIDENTIAL LOCAL STREETS
806 TYPICAL TRUNCATED DOME PANEL
FOR ACCESS RAMPS
807 TYPICAL FIRE ACCESS ROAD SIGNS
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
SheetTHE QUARRY BY WATERMARKThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 43
20'
4" White Line
20'
4'
6'
Flow Line
Curb
2'VAN-ACCESSIBLEPARKINGMIN.MIN.ONE IN EVERYEIGHT ACCESSIBLESPACES, BUT NOTLESS THAN ONE,SHALL BE VANACCESSIBLE.ONE SIGNPER SPACEREQUIREDREQUIREDPER SPACEONE SIGNREQUIREDPER SPACEONE SIGNCAR ACCESSIBLEVAN ACCESSIBLE"UNIVERSAL DESIGN"CAR & VAN ACCESSIBLEORA "UNIVERSAL" PARKING SPACE DESIGN MAY BE USED.THIS DESIGN IS USED TO ACCOMMODATE CAR & VANACCESSIBLE PARKING SPACES, WHICH ELIMINATES THENEED FOR TWO SIGN TYPES.8'5'8'8'8'8'11'5'11'11'5'RESERVEDRESERVEDPARKINGRESERVEDPARKINGR7-8R7-8R7-8SW SAMPLEAVE
NOTES:
1. Street name must be 6" (min.) capital white letters, FHWA Series "B".
2. Prefix must be 2" letters, FHWA Series "B" and placed on the upper left.
3. Suffix must be 2" (min.) letters and block number must be 2" (min.) numbers, FHWA Series "B".
4. Overall sign length dimension varies according to length of street name.
5. All sign lettering and green background material must be at least Diamond Grade
sheeting per FHWA; No silk screened signs will be permitted.
6. Street numbers shall always point to higher block number.
7. Aluminum sign blank shall be 0.10 thickness with 3/4" radius corners.
8. Loveland only, signalized intersection signs shall be 18" (min.) in height.
9. All street name signs shall be retroreflective.
2400
Length Varies by Street Name
8"
1/2"
2-1/4"1/2"
2-3/4"
1/2"
2-1/2" Hwy B Series1" min.
2" max.
6" Hwy B Series
2-1/2" Hwy B Series,
Centered on Logo
3-3/4"
2-3/4"
1" min.
2" max.
1/2"
1/2"1/2"
FORT COLLINS ONLY
Notes: 1. Set ramp slopes using the center of theramp. 2. Truncated dome warning panel: Install panels along with the concrete pour for theramp. Specifications for the panel materialwill be provided upon request. 3. Each ramp shall align perpendicular to thestreet in which the ramp is provided to cross. 4. Refer to standard drawing 1606 in the Laimer County urban area street standardsfor other necessary criteria needed to construct these ramps that is not specifiedon this drawing. 5. Construct the ramps and walk so the cornerarea all drains to the street. 6. If curb and gutter are poured monolithic withramp, place dome edge at back of curb asshown. If not poured monolithic, place dome edge 6" from back of curb.PLAN VIEWNTSRamp
FlareGutterRampRampFlareCurbCurbConc. FlarePanelsPanelsTruncated domepanels:1-2'x2.5'1-2'x2'Truncated Dome WarningDetection Plan LocationsLEGEND:BOC- Back of curb⅊ Property LinePT - Point of TangencyFlow line Section A-A NTS4'-6"2'-0"2'-6"2'-0"t
Varies
Varies 4.5'6.0'.5'1.5'4.5'1.5 '12.0'12.0'4.5'.5'6.0'4.5'L
a
n
d
s
c
a
p
e
d
A
r
e
a
PT CurbAA6" Curb(TYP)0" CurbFull heightcurbTruncated domewarning detection⅊PT of walkR15.0'⅊⅊ & BOW5'-6" BOC to walk w/ vertical curb5'-7" BOC to walk w/ drive over curbConc. SidewalkArea to be landscapedConc. walkGutterorApronTruncate DomeWarning Panel1:12 Max slope1:20SlopePT of curbreturn6"Conc. Flare6" Curb(TYP)See note 6
CurbFlareVaries
CurbFlareRampCurbCurb
FlareRampVaries PanelsPanels6"RampWidth:4.5'5.0'6.0'7.0'8.0'Note:Truncated dome panels areavailable in 2'x2' squaresand 2'x2.5' rectangles.Combine the widths to fitthe ramp. Panels may becut to no less than a 2'x1.5'size.Panel WidthCombinations:2'+2.5'2.5'+2.5'2'+2'+2'2.5'+2'+2.5'2'+2'+2'+2'Notes: 1. Truncated dome warning panel: Install panels along with the concrete pour for the ramp. Specifications for the panel and installation instructions will be provided upon request. 2. This drawing shows vertical curb.For Drive Over Curb the warning detection location shall be placed inthe same position 6" back from theback of curb. 3. If curb and gutter are poured monolithic with ramp, place domeedge at back of curb as shown. Ifnot poured monolithic, place domeedge 6" from back of curb.Case 1-Directional RampsCase 2-Non-Directional RampsVaries
PanelsRampPanelsFlareCurbCase 3-Mid-Block Ramps6"PanelsPanelsFlare6"FlareVaries
FORT COLLINS ONLY
Aligned with
Pedestrian flow
GutterorApron℄Center line of rampBOC-Back of CurbFOC -Face of Curb-Flow lineVaries
2'-0"
2'-0"AAFOC or ℄
2'-0"BOCBOC1:12 max slope1:20slopePanels embedded in theconcrete ramps Section A-A (Center line of ramp)NTSFlow line Curb
and Gutter
BOC
See Note 3
NOTES:
1. THE SIGN PLATE SHALL BE A MINIMUM OF 12"X18" WITH A THICKNESS OF .080
ALUMINUM CONSTRUCTION.
2. THE SIGN FACE SHALL HAVE A WHITE REFLECTIVE BACKGROUND WITH A RED
LEGEND. USE THE STANDARD 3M SCOTCHLITE SIGN FACE NUMBER R7-32 OR
EQUIVALENT, WITH RED LETTERING AS SHOWN ABOVE.
3. ARROWS MAY BE NEEDED (LEFT, RIGHT OR DOUBLE), TO DESIGNATE BEGIN AND END OF
NO PARKING AREA.
FIRE
LANE
NO
PARKING
BY ORDER OF THE
FIRE MARSHAL
STANDARD
FIRE LANE SIGN DETAIL
UNIVERSAL
FIRE LANE SIGN DETAIL
18"
2"
1 1/2"
3/4"
12"12"
FIRE LANE
COLOR SCHEDULE
BACKGROUND
"P"
RED
WHITE
BLACK
LEGEND, CIRCLE DIAGONAL, BORDER,
"ARROW", "FIRE LANE"
(FORT COLLINS ONLY)
803 12' CONCRETE TRAIL/
ACCESS ROAD SECTION
PAVEMENT CROSS-SECTIONS
802
LOCATION COMPOSITE ASHPALT SECTION
(INCHES ASPHALT / INCHES ABC)
FULL DEPTH ASPHALT
SECTION
(INCHES ASPHALT)
RIGID PAVEMENT
(INCHES PCCP/INCHES ABC or SCS)
PARKING AREAS 4.0 / 7 6.0 -
DRIVE AISLES 4.5 / 9 7.0 5 / 5 (ABC)
HEAVY DUTY 6 / 6 (ABC)
ABC = AGGERGATE BASE COURSE, PCCP = PORTLAND CEMENT CONCRETE PAVEMENT
SCS = SCARIFIED/COMPACTED SUBGRADE
--