HomeMy WebLinkAboutPLANETSCALE LIVING - PDP200015 - SUBMITTAL DOCUMENTS - ROUND 4 - DRAINAGE REPORT
HCI Engineering, - 621 SouthPark Dr., Suite 1600, Littleton CO, 80120 - 720-252-3484
Page 1 of 9
HCI ENGINEERING
A division of
HABERER CARPENTRY INC.
DRAINAGE REPORT
FOR:
Planetscale Living – Affordable Housing Project
906 E. Stuart Street, Fort Collins, CO
Owner:
Planetscale Limited
ATTN: Serdar Badem
12933 Regan Lane, Saratoga, CA
Serdar.Badem@Gmail.com
Engineer Contact(s):
HCI Engineering
T. Garrett Goodlin, P.E.
621 Southpark Dr., Suite 1600
Littleton, CO 80120
PH: 303-979-3900
FX: 303-278-7814
7/30/2021
Estimated Project Dates:
Project Start Date: 10/1/2021 Project Completion Date: 4/30/2022
HCI Engineering, - 621 SouthPark Dr., Suite 1600, Littleton CO, 80120 - 720-252-3484
Page 2 of 9
Table of Contents:
I. General Location & Description ................................................................................................................3
A. Project Location .............................................................................................................................. 3
B. Description of Property .................................................................................................................. 3
C. Topographic Data............................................................................................................................ 4
D. FEMA and Flood Zone Data ......................................................................................................... 4
E. Soils Information ............................................................................................................................. 4
II. Drainage Facility Design ............................................................................................................................4
A. Hydrological Criteria ....................................................................................................................... 4
III. Stormwater Management Facility Design .................................................................................................5
A. Stormwater Conveyance Facilities ................................................................................................. 5
B. Easements ....................................................................................................................................... 5
C. Compliance with Standards ............................................................................................................ 5
D. Maintenance Plan ....................................................................................................................... 6
E. Conclusion ....................................................................................................................................... 6
IV. References .................................................................................................................................................6
Appendix – A, Maps & Reference Materials .............................................................................................................7
Appendix – B, Hydrology Calculations ......................................................................................................................8
Appendix – C, Drainage Plan .....................................................................................................................................9
HCI Engineering, - 621 SouthPark Dr., Suite 1600, Littleton CO, 80120 - 720-252-3484
Page 3 of 9
I. General Location & Description
A. Project Location
The Site, an area consisting of 0.32 acres, is located at 906 E. Stuart Street, Fort Collins, CO,
which is more precisely located in a part of Tract 7, East Acres Subdivision, lying in the NE
Quarter of Section 24, Township 7 North, Range 69 west of the 6th Principal Meridian, City of
Fort Collins, County of Larimer, State of Colorado. The Site is bordered by Stuart Street Right-of-
Way to the south, and existing residential land uses to the west, north and east. Refer to the
following map.
SITE MAP
The Site is approximately located at
Latitude, 40⁰ 33’ 49” N – Longitude, 105⁰ 03’ 40” W
B. Description of Property
The Site is currently developed with an existing two-story residence with associated driveway
and yard. Site improvements will consist of a proposed Four Unit townhome with associated
permeable paver drive and parking, with yard. As part of this development, construction
activities will consist of a new structure built on the existing foundation, utility installation, ,
paving, fine grading and landscaping. In addition to this, the site driveway and parking lot are
proposed to be constructed of permeable pavers. The Site disturbed area and construction
HCI Engineering, - 621 SouthPark Dr., Suite 1600, Littleton CO, 80120 - 720-252-3484
Page 4 of 9
limits total approximately 0.28 acres. The existing and developed Site and basin percent
impervious values are listed in Table 1 below:
Table 1
ONSITE % Impervious
Existing Site
Proposed Site
50.8% (0.32 acres)
40.5% (0.32 acres)
C. Topographic Data
The General Existing Site Topographic Conditions for The Site are itemized in Table 2 below:
Table 2
Description Result Location of Occurrence
Highest Elevation 4982 South of Site
Lowest Elevation 4980 North of Site
Steepest Slope 25% East limits
Average Slope 1 - 3% Most of The Site
D. FEMA and Flood Zone Data
According to the FEMA Flood Insurance Rate Map: Community-Panel No. 08069C0983H,
Effective May 2, 2012, The Site is located in Zone X unshaded. These are areas of 0.2% annual
chance of flood; areas of 1% annual chance flood with average depths of less than 1 foot or
with drainage areas less than 1 square mile; and areas protected by levees from 1% annual
chance flood. The Regulatory Flood Elevation adjacent to The Site is coincident with the project
survey elevation of 4953 (worst-case scenario).
E. Soils Information
Soil Classifications for The Site are reported by N.R.C.S. as consisting of Type C soil for 100% of
The Site (Santana loam, 1 to 3 percent slopes) Refer to Attachments for the included ‘N.R.C.S.
Websoil Survey Report’. With Kw value averaging 0.32, The Site has a high to susceptibility to
sheet and rill erosion by water. With a Wind erodibility group of 5 The Site has a low
susceptibility to erosion due to wind.
II. Drainage Facility Design
A. Hydrological Criteria
Due to the size of this site, the rational method was used to determine the runoff for the 5-yr
and 100-yr storm event. (See Appendix B) The rainfall intensities given in the Urban Storm
Drainage Criteria Manual (USDCM) are as follows:
TABLE 3
1-HOUR POINT RAINFALL VALUES FOR CITY OF COMMERCE CITY (INCHES)
2-YR 5-YR 10-YR 100-YR
0.83 1.09 1.40 2.86
HCI Engineering, - 621 SouthPark Dr., Suite 1600, Littleton CO, 80120 - 720-252-3484
Page 5 of 9
III. Stormwater Management Facility Design
A. Stormwater Conveyance Facilities
There are no existing drainage structures or features on the site. Flows are directed east away
from the building toward the existing concrete driveway, or west to the existing side yard.
Flows then sheet flow to the north or east off the property. These drainage patterns are
mimicked in the proposed condition. Flows produced on the west side of the property are
directed away from the building to a new landscape swale with underdrain to ensure adequate
slope away from the structure. Flows are directed north to the new permeable pavers. Flows
produced on the south and east of the building are directed to the permeable pavers where
they will either infiltrate or be directed to the north and east.
Historic Direct Runoff Comparison
The site has been evaluated as a single basin of 0.32 acres. The composite percent impervious
of the existing site is 50.8% and the 10-year and 100-year flows are 0.23 & 0.63 CFS,
respectively. The composite percent impervious of the proposed site is 40.5% (10.3% less) and
the 10-year and 100-year flows are 0.18 & 0.48 CFS (0.05 CFS and 0.15 CFS less), respectively.
The change in the Direct Peak Runoff values for The Site for the 5 and 100-year storm events
are shown in the following Table.
TABLE 4
DIRECT RUNOFF SUMMARY
Area Area % Imp.
Time of
Concentration
Runoff
Coefficient
Direct Basin
Runoff
Design (Acres) C10 C100 Q10 (cfs)
Q100
(cfs)
HISTORIC 0.32 50.8% 6.64 0.51 0.69 0.23 0.63
TOTAL PROPOSED 0.32 40.5% 7.60 0.40 0.52 0.18 0.48
B. Easements
There is an existing HOA easement directly east of this property, between Spring Meadow
Court ROW and The Site. The HOW has stated that it will not allow any construction and/or
stormwater work in this area and is also not willing to grant any drainage easements to
accommodate any increase in flows.
C. Compliance with Standards
The proposed Site has been evaluated using the rational method as set forth by UDSCM. Both
the 100-yr and 10-yr storms have been evaluated. The stormwater conveyance system has
been designed to comply with conveyance methods and capacities. This project will be
complying with the Low Impact Development drainage requirements set forth in the City of Fort
Collins Stormwater Criteria Manual – LID Implementation Manual. (See Appendix A) The project
will comply with both options for the implementation of LID systems, as all new private
impervious area will be treated by the proposed permeable pavers. The required detached
public sidewalk drains south to the Stuart Street ROW.
HCI Engineering, - 621 SouthPark Dr., Suite 1600, Littleton CO, 80120 - 720-252-3484
Page 6 of 9
D. Maintenance Plan
The owner will compete a monthly maintenance inspection to clean and remove and trash,
debris and vegetation that is restricting or not allowing permeable pavers, landscape areas and
underdrains to drain. This will include mowing or trimming of landscaped areas. Any repairs to
the grading because of washout and/or sedimentation will be removed.
E. Conclusion
The proposed project has been analyzed utilizing the City of Fort Collins Stormwater Criteria
Manual. This drainage letter and associated calculations are limited to the project shown by
the attached Drainage Plan. Based on the above findings and attached calculations HCI
Engineering finds the proposed development to be in compliance with the drainage criteria set
forth in Report 1. No negative impacts are anticipated as a result of this development to
adjacent properties or downstream.
Sincerely,
T. Garrett Goodlin, P.E.
HCI Engineering
IV. References
1. City of Fort Collins Stormwater Criteria Manual (December 2018), by The City of Fort Collins.
2. Drainage Criteria Manual (Volume 1, 2 & 3), by Mile High and Flood Control District, current
versions.
3. FEMA website Flood Insurance Rate Maps.
4. USDA, Web Soil Survey, Soil Map Data.
HCI Engineering, - 621 SouthPark Dr., Suite 1600, Littleton CO, 80120 - 720-252-3484
Page 7 of 9
Appendix – A, Maps & Reference Materials
• FEMA Firmette
• NRCS Soil Map
• NRCS Soil Data
• CFCSCM Excerpt
o Low Impact Development
o Runoff Coefficients
o Percent Impervious Values
National Flood Hazard Layer FIRMette
0 500 1,000 1,500 2,000250
Feet
Ü
SEE FIS REPORT FOR DETAILED LEGEND AND INDEX MAP FOR FIRM PANEL LAYOUT
SPECIAL FLOOD
HAZARD AREAS
Without Base Flood Elevation (BFE)
Zone A, V, A99
With BFE or DepthZone AE, AO, AH, VE, AR
Regulatory Floodway
0.2% Annual Chance Flood Hazard, Areas
of 1% annual chance flood with average
depth less than one foot or with drainage
areas of less than one square mileZone X
Future Conditions 1% Annual
Chance Flood HazardZone X
Area with Reduced Flood Risk due to
Levee. See Notes.Zone X
Area with Flood Risk due to LeveeZone D
NO SCREEN Area of Minimal Flood Hazard Zone X
Area of Undetermined Flood HazardZone D
Channel, Culvert, or Storm Sewer
Levee, Dike, or Floodwall
Cross Sections with 1% Annual Chance
17.5 Water Surface Elevation
Coastal Transect
Coastal Transect Baseline
Profile Baseline
Hydrographic Feature
Base Flood Elevation Line (BFE)
Effective LOMRs
Limit of Study
Jurisdiction Boundary
Digital Data Available
No Digital Data Available
Unmapped
This map complies with FEMA's standards for the use of
digital flood maps if it is not void as described below.
The basemap shown complies with FEMA's basemap
accuracy standards
The flood hazard information is derived directly from the
authoritative NFHL web services provided by FEMA. This map
was exported on 7/29/2021 at 11:43 AM and does not
reflect changes or amendments subsequent to this date and
time. The NFHL and effective information may change or
become superseded by new data over time.
This map image is void if the one or more of the following map
elements do not appear: basemap imagery, flood zone labels,
legend, scale bar, map creation date, community identifiers,
FIRM panel number, and FIRM effective date. Map images for
unmapped and unmodernized areas cannot be used for
regulatory purposes.
Legend
OTHER AREAS OF
FLOOD HAZARD
OTHER AREAS
GENERAL
STRUCTURES
OTHER
FEATURES
MAP PANELS
8
B 20.2
The pin displayed on the map is an approximate
point selected by the user and does not represent
an authoritative property location.
1:6,000
105°3'59"W 40°34'3"N
105°3'21"W 40°33'36"N
Basemap: USGS National Map: Orthoimagery: Data refreshed October, 2020
Soil Map—Larimer County Area, Colorado
Natural Resources
Conservation Service
Web Soil Survey
National Cooperative Soil Survey
7/29/2021
Page 1 of 3449029844903054490312449031944903264490333449034044903474490354449029844903054490312449031944903264490333449034044903474490354494808494815494822494829494836494843494850
494808 494815 494822 494829 494836 494843 494850
40° 33' 50'' N 105° 3' 40'' W40° 33' 50'' N105° 3' 38'' W40° 33' 48'' N
105° 3' 40'' W40° 33' 48'' N
105° 3' 38'' WN
Map projection: Web Mercator Corner coordinates: WGS84 Edge tics: UTM Zone 13N WGS84
0 10 20 40 60
Feet
0 4 8 16 24
Meters
Map Scale: 1:284 if printed on A portrait (8.5" x 11") sheet.
Soil Map may not be valid at this scale.
MAP LEGEND MAP INFORMATION
Area of Interest (AOI)
Area of Interest (AOI)
Soils
Soil Map Unit Polygons
Soil Map Unit Lines
Soil Map Unit Points
Special Point Features
Blowout
Borrow Pit
Clay Spot
Closed Depression
Gravel Pit
Gravelly Spot
Landfill
Lava Flow
Marsh or swamp
Mine or Quarry
Miscellaneous Water
Perennial Water
Rock Outcrop
Saline Spot
Sandy Spot
Severely Eroded Spot
Sinkhole
Slide or Slip
Sodic Spot
Spoil Area
Stony Spot
Very Stony Spot
Wet Spot
Other
Special Line Features
Water Features
Streams and Canals
Transportation
Rails
Interstate Highways
US Routes
Major Roads
Local Roads
Background
Aerial Photography
The soil surveys that comprise your AOI were mapped at
1:24,000.
Warning: Soil Map may not be valid at this scale.
Enlargement of maps beyond the scale of mapping can cause
misunderstanding of the detail of mapping and accuracy of soil
line placement. The maps do not show the small areas of
contrasting soils that could have been shown at a more detailed
scale.
Please rely on the bar scale on each map sheet for map
measurements.
Source of Map: Natural Resources Conservation Service
Web Soil Survey URL:
Coordinate System: Web Mercator (EPSG:3857)
Maps from the Web Soil Survey are based on the Web Mercator
projection, which preserves direction and shape but distorts
distance and area. A projection that preserves area, such as the
Albers equal-area conic projection, should be used if more
accurate calculations of distance or area are required.
This product is generated from the USDA-NRCS certified data as
of the version date(s) listed below.
Soil Survey Area: Larimer County Area, Colorado
Survey Area Data: Version 15, Jun 9, 2020
Soil map units are labeled (as space allows) for map scales
1:50,000 or larger.
Date(s) aerial images were photographed: Aug 11, 2018—Aug
12, 2018
The orthophoto or other base map on which the soil lines were
compiled and digitized probably differs from the background
imagery displayed on these maps. As a result, some minor
shifting of map unit boundaries may be evident.
Soil Map—Larimer County Area, Colorado
Natural Resources
Conservation Service
Web Soil Survey
National Cooperative Soil Survey
7/29/2021
Page 2 of 3
Map Unit Legend
Map Unit Symbol Map Unit Name Acres in AOI Percent of AOI
95 Satanta loam, 1 to 3 percent
slopes
0.4 100.0%
Totals for Area of Interest 0.4 100.0%
Soil Map—Larimer County Area, Colorado
Natural Resources
Conservation Service
Web Soil Survey
National Cooperative Soil Survey
7/29/2021
Page 3 of 3
RUSLE2 Related Attributes
This report summarizes those soil attributes used by the Revised Universal Soil
Loss Equation Version 2 (RUSLE2) for the map units in the selected area. The
report includes the map unit symbol, the component name, and the percent of
the component in the map unit. Soil property data for each map unit component
include the hydrologic soil group, erosion factor Kf for the surface horizon,
erosion factor T, and the representative percentage of sand, silt, and clay in the
mineral surface horizon. Missing surface data may indicate the presence of an
organic layer.
Report—RUSLE2 Related Attributes
Soil properties and interpretations for erosion runoff calculations. The surface
mineral horizon properties are displayed or the first mineral horizon below an
organic surface horizon. Organic horizons are not displayed.
RUSLE2 Related Attributes–Larimer County Area, Colorado
Map symbol and soil name Pct. of
map unit
Slope
length
(ft)
Hydrologic group Kf T factor Representative value
% Sand % Silt % Clay
95—Satanta loam, 1 to 3
percent slopes
Satanta 90 200 C .32 5 43.0 39.0 18.0
Data Source Information
Soil Survey Area: Larimer County Area, Colorado
Survey Area Data: Version 15, Jun 9, 2020
RUSLE2 Related Attributes---Larimer County Area, Colorado
Natural Resources
Conservation Service
Web Soil Survey
National Cooperative Soil Survey
7/29/2021
Page 1 of 1
(From Fort Collins Stormwater Criteria Manual - 6.0 Low Impact Development)
This Section of this Chapter presents information that is specific to the City of Fort Collins and may be a
significant deviation from the information presented in the UDFCD Manuals. Utilizing UDFCD
methodologies for Low Impact Development (LID) designs may not be accepted by FCU.
In February 2013, Fort Collins City Council adopted Ordinance No. 152, 2012, to incorporate provisions
implementing LID principles; with the goal to declare that the purpose of the City Stormwater Utility is
to provide an integrated, sustainable stormwater management program that reflects the community’s
values of protecting and restoring the City’s watersheds. This was subsequently modified and updated in
January 2016 with Ordinance No. 007, 2016 to allow for some added flexibility in the implementation of
the LID policy.
Reference: Both the initial LID ordinance, Ordinance No. 152, 2012, and the subsequent
ordinance, Ordinance No. 007, 2016, can be found on the City of Fort Collins website.
LID is simply defined as an integrated, sustainable stormwater management program that requires a
distributed, closer to the source stormwater runoff control that simulates natural processes and relies
mainly on filtration and infiltration to locally treat and manage stormwater runoff.
Integration of LID systems into the drainage design is required for all development projects in order to
comply with the City’s policies on LID, the requirements of this Manual, the City Code and the Land Use
Code. LID systems provide a higher degree of stormwater quality treatment than that provided with
standard water quality design. The implementation of LID systems requires one of the following two
options:
1) 50% of the newly added or modified impervious area must be treated by LID techniques and
25% of new paved (vehicle use) areas must be pervious.
2) 75% of all newly added or modified impervious area must be treated by LID techniques.
Impervious surfaces are defined as hardscape surfaces that do not allow stormwater to infiltrate into
the ground. Impervious surfaces include asphalt and concrete surfaces, concrete curbs, gutters,
sidewalks, patios and rooftops. (Impervious surface areas must be assumed for single family residential
lots when overall impervious areas are being determined for residential developments. The assumed
areas must then be included in LID calculations.) “Added” impervious area stated in the two options
above is further defined as existing vegetation (or pervious) areas becoming hardscape (or impervious)
areas. “Modified” impervious area stated in the two options above is further defined as existing
impervious areas on an existing site being removed and replaced with other impervious surfaces through
a redevelopment process (i.e. existing asphalt surface becoming a rooftop surface). Mill and overlay of
asphalt areas is not considered a “modified” impervious area. “Paved” areas, as stated in option 1 above
are generally considered to be private vehicle use areas only.
Reference: Refer to the City of Fort Collins LID Implementation Manual in Appendix C for
detailed information and requirements on LID systems.
(From Fort Collins Stormwater Criteria Manual - 6.2 Permeable Pavement)
The term “permeable pavement” is a general term to describe any one of several pavement systems that
allow infiltration of water into the layers below the pavement through openings within the pavement
surface. Use of permeable pavements is an accepted Low Impact Development (LID) practice in Fort
Collins and is often used in combination with other BMPs to provide full treatment and slow release of the
WQCV. In addition, there are some installations in Fort Collins that have also been designed with an outlet
control and increased depth of aggregate material in order to provide quantity detention in excess of the
water quality (80th percentile) storm event. Design considerations for permeable pavement systems are
presented in the LID Implementation Manual, included in Appendix C.
Included here are some general design requirements applicable for all types of LID system designs in
Fort Collins.
• Overall added or modified impervious areas that amount to less than 1000 square feet (<
1000 sf) on a site will not require LID system treatment for water quality.
• For development sites that are adding or modifying 1000 square feet of imperviousness or
more (≥ 1000 sf) are required to implement LID system treatment at the site. The LID system
is allowed to treat existing imperviousness in exchange for the newly added imperviousness
if the surface character is similar (e.g. existing pavement may be treated in lieu of newly
added rooftop)
• For single-family residential developments, LID must be placed in tracts or common areas
for ownership and maintenance by the HOA. LID systems installed as part of the
development requirement shall not be placed on single-family lots.
• LID is not required for private, single-family residential improvement projects that are not a
part of a larger subdivision project. (i.e. an existing lot in an older part of Fort Collins that is
being re-built)
FORT COLLINS STORMWATER CRITERIA MANUAL Hydrology Standards (Ch. 5)
3.0 Rational Method
3.2 Runoff Coefficients
Page 4
3.2 Runoff Coefficients
Runoff coefficients used for the Rational Method are determined based on either overall land use or
surface type across the drainage area. For Overall Drainage Plan (ODP) submittals, when surface types
may not yet be known, land use shall be used to estimate flow rates and volumes. Table 3.2-1 lists the
runoff coefficients for common types of land uses in the City.
Table 3.2-1. Zoning Classification - Runoff Coefficients
Land Use Runoff Coefficient (C)
Residential
Urban Estate 0.30
Low Density 0.55
Medium Density 0.65
High Density 0.85
Commercial
Commercial 0.85
Industrial 0.95
Undeveloped
Open Lands, Transition 0.20
Greenbelts, Agriculture 0.20
Reference: For further guidance regarding zoning classifications, refer to the Land Use
Code, Article 4.
For a Project Development Plan (PDP) or Final Plan (FP) submittals, runoff coefficients must be based on
the proposed land surface types. Since the actual runoff coefficients may be different from those
specified in Table 3.2-1, Table 3.2-2 lists coefficients for the specific types of land surfaces.
FORT COLLINS STORMWATER CRITERIA MANUAL Hydrology Standards (Ch. 5)
4.0 SWMM
4.1 Input Parameters
Page 11
Table 4.1-2. Land Use - Percent Impervious
Land Use
Percent Impervious
(%)
Residential
Urban Estate 30
Low Density 50
Medium Density 70
High Density 90
Commercial
Commercial 80
Industrial 90
Undeveloped
Open Lands, Transition 20
Greenbelts, Agriculture 2
Offsite Flow Analysis (when
Land Use not defined) 45
Reference: For further guidance regarding zoning classifications, refer to the Land Use
Code, Article 4.
For Final Plan (FP) submittals, impervious values must be based on the proposed land surface types.
Refer to Table 4.1-3 for recommended percent impervious values.
Table 4.1-3. Surface Type – Percent Impervious
Surface Type
Percent Impervious
(%)
Hardscape or Hard Surface
Asphalt, Concrete 100
Rooftop 90
Recycled Asphalt 80
Gravel 40
Pavers 40
Landscape or Pervious Surface
Playgrounds 25
Lawns, Sandy soil 2
Lawns, Clayey soil 2
HCI Engineering, - 621 SouthPark Dr., Suite 1600, Littleton CO, 80120 - 720-252-3484
Page 8 of 9
Appendix – B, Hydrology Calculations
• Rational Calculations
o Percent Impervious
o Time of Concentration
o Direct Runoff 10-Year Storm
o Direct Runoff 100-Year Storm
o Direct Runoff Summary & routed Runoff Summary
Project:906 E. Stuart Street Surface % Imp.C2 Value C5 Value C10 Value C100 Value
Project Number:21_23 Paved Streets 100%0.83 0.86 0.87 0.89
Date:7/30/2021 Roofs 90%0.74 0.77 0.80 0.85
Lawns, clayey soil 2%0.01 0.05 0.15 0.49
Permeable Pavers 40%0.29 0.32 0.38 0.61
Soil Type: C & D
Sub-basin I.D.
Formula: [(Area)(C Value)+(Area)(C Value)+(Area)(C Value)]/(Total Area)
Paved Roof Landscape Pavers
Existing Conditions 5267 1865 6806 0 13938 50.8%0.42 0.45 0.51 0.69
Proposed 3647 2116 4531 3644 13938 40.5%0.33 0.36 0.40 0.52
C10 C100
Surface Type Area (S.F.)
HCI ENGINEERING
A division of
HABERER CARPENTRY INC.
NRCS Hydrologic Soil Type (Per NRCS Web Soil Survey)
Basin I.D.Total Area
(S.F.)% Impervious C2 C5
Values per Figures 6-2 in Runoff Chapter of USDCM for Type C Soils
Project:
Project Number:
Date:
Final tc
Basin I.D.AREA
(Ac)C5
Length
(ft)
SLOPE
(%)ti
Length
(ft)
SLOPE
(%)Cv
Vel.
(FPS)tt COMP tc
Total
Length Ft
tc =
(26-17i)+Lt/(60(14i+9)St^(1/2))Min
Existing Conditions 0.32 0.45 65 3.0 6.64 0 1.0 20 2.0 0.00 6.64 65 17.36 6.64
Proposed 0.32 0.36 65 3.0 7.60 0 1.0 20 2.0 0.00 7.60 65 19.12 7.60
Table RO-2—Conveyance Coefficient, Cv
2.5
5
7
10
15
20
Short pasture and lawns
Nearly bare ground
Grassed waterway
Paved areas and shallow paved swales
Conveyance Coefficient, K
HCI ENGINEERING
A division of
HABERER CARPENTRY INC.
TIME OF CONCENTRATION
Type of Land Surface
Heavy meadow
Tillage/field
906 E. Stuart Street
21_23
7/30/2021
Initial / Overland Time (ti) Travel Time (tt) tc Check (Urbanized Basins)Basin Data
Project:906 E. Stuart StreetProject Number:21_23Date:7/30/2021AreaAreaRunofftcC x AIntensity (I)QDesign PointDesign(ac)Coeff(min)(AC)in/hr(cfs)Existing Conditions0.320.516.640.161.400.23Proposed0.320.407.600.131.400.181-Hour Rainfall Depths for Design StormsDesign Storm2-Year5-Year10-Year100-YearDepth (in)0.831.091.402.86Per NOAA Rainfall DataHCI ENGINEERING A division of HABERER CARPENTRY INC. DIRECT RUNOFF 10-YR STORM
Project:906 E. Stuart StreetProject Number:21_23Date:7/30/2021AreaAreaRunofftcC x AIntensity (I)QDesign PointDesign(ac)Coeff(min)(AC)in/hr(cfs)Existing Conditions0.320.696.640.222.860.63Proposed0.320.527.600.172.860.481-Hour Rainfall Depths for Design StormsDesign Storm2-Year5-Year10-Year100-YearDepth (in)0.831.091.402.86Per NOAA Rainfall DataHCI ENGINEERING A division of HABERER CARPENTRY INC. DIRECT RUNOFF 100-YR STORM
Project: 906 E. Stuart StreetProject Number: 21_23Date: 7/30/2021AreaArea% Imp.Design(Acres)C10 C100Q10 (cfs)Q100 (cfs)Existing Conditions0.3250.8%6.640.510.690.230.63Proposed0.3240.5%7.600.400.520.180.48HCI ENGINEERING A division of HABERER CARPENTRY INC. Runoff Coefficient Direct Basin RunoffDIRECT RUNOFF SUMMARYTime of Concentration
HCI Engineering, - 621 SouthPark Dr., Suite 1600, Littleton CO, 80120 - 720-252-3484
Page 9 of 9
Appendix – C, Drainage Plan
SS
M
CO
CO
80.75
80.75
80.51
80.24
MATCH EX.
4980.17
MATCH EX.
4980.01
MATCH EX.
4980.22
80.63
81.68
80.63
81.737.4%7.4%6.0%23.9%
1.1%
0.
5%
0.
5%
0.
5%0.5%3.6%0.8%1.5%FFE = 4980.75
80.27
80.36
80.66
81.6881.57
MATCH EX.
4981.62
MATCH EX.
4981.55 1.5%80.66
81.65 81.58
81.65
MATCH EX.
4981.7081.68
MATCH EX.
4981.64
MATCH EX.
4981.65
MATCH EX.
4981.09
MATCH EX.
4980.05
MATCH EX.
4980.12
MATCH EX.
4980.15 80.21 80.59
80.74
80.75
80.75
80.69
80.69
80.69
80.69
80.6980.69 80.69 80.59
80.73
81.72
80.70
80.75
80.7480.74
80.7480.7480.74
80.74
80.70
4981
1.5%1.1%1.3%1.4%1.4%7.4%0.5%0.5%0.9%0.1%0.1%0.3%1.1%1.6%
0.3%7.4%N
REVISIONS:
Drawn By:
Sheet
Sheet Name:
No.Date:Description:FILENAME: J:\2021\21_23 906 e. stuart st\CAD\Plans\21-23 - CD - GRADING PLAN.dwg PLOTDATE: 2021-07-30 Checked By:
Date Issued:
Project No:
CALL 811 2-BUSINESS DAYS IN
ADVANCE BEFORE YOU DIG,
GRADE, OR EXCAVATE FOR THE
MARKING OF UNDERGROUND
MEMBER UTILITIES.
Know what's below,
Call before you dig.
UTILITY PLANS
PLANETSCALE LIVING - AFFORDABLE HOUSING PROJECT
A PART OF TRACT 7, EAST ACRES LYING IN THE NORTHEAST 1/4 OF THE NORTHEAST 1/4 OF SECTION 24, TOWNSHIP 7
NORTH, RANGE 69 WEST OF THE 6TH P.M., COUNTY OF LARIMER, STATE OF COLORADO
906 E. STUART ST., FORT COLLINS
COLORADO
UTILITY PLANSPLANETSCALE LIVING - AFFORDABLE HOUSING PROJECT906 E. STUART ST., FORT COLLINS, CONumber:
A DIVISION OF
HABERER CARPENTRY INC.
621 SOUTHPARK DR., SUITE 1600
LITTLETON CO, 80120
PHONE: (303) 979-3900
INFO@HABERERGROUP.COM
HCI 21_23
1 07.30.21 1ST SUB
7/30/2021
KZH
TGG
N
30'20'10'0'
SCALE: 1" = 10'
GRADING PLAN
C2.1
DRAINAGE LEGEND
DRAINAGE BASIN
FLOW ARROW
BASIN ID
C100AREA (AC)
C10
MAJOR BASIN BOUNDARY
B3-6
2.8 0.47
0.76
PRO.
0.32 0.40
0.52
XXXX
5421
5420
XXXSLOPE
MAJOR CONTOUR
MINOR CONTOUR
SPOT ELEVATION