Loading...
HomeMy WebLinkAboutSTETSON CREEK PUD, FIRST FILING - FINAL - 16-89F - REPORTS - RECOMMENDATION/REPORT W/ATTACHMENTSITEM NO. 8 MEETING DATE 1-24-94 STAFF --Te-dLShenard City of Fort Collins PLANNING AND ZONING BOARD STAFF REPORT PROJECT: Stetson Creek, First Filing, Final P.U.D., #16-89F (Formerly Brookside Village at Rock Creek P.U.D.) APPLICANT: Geneva Homes, Inc. c/o Cityscape Urban Design 3555 Stanford Road, Suite 105 Fort Collins, CO 80525 OWNER: Mr. T.J. Morroni et.al. P.O. Box 16383 Denver, CO. 80216 PROJECT DESCRIPTION: This is a request for Final P.U.D. for 50 single family lots on 16.99 acres. The site is located east of Timberline Road approximately one-half mile south of Harmony Road. The zoning is R-L-P, Low Density Planned Residential. EXECUTIVE SUMMARY: Stetson Creek is the renamed Brookside Village at Rock Creek P.U.D. The P.U.D. has satisfied the condition of approval that the property be rezoned from T, Transition, to R-L-P, Low Density Planned Residential. The request conforms to the Overall Development Plan and is in substantial conformance with the Preliminary P.U.D. The Final P.U.D. satisfies the All Development Criteria of the L.D.G.S. The project is feasible from a traffic engineering standpoint. COMMUNITY PLANNING AND ENVIRONMENTAL SERVICES 281 N. College Ave. P.O. Box 580 Fort Collins, CO 80522-0580 (303) 221-6750 PLANNING DEPARTMENT 0 :7 Stetson Creek P.U.D., First Filing - Final, #16-89F January 24, 1994 P & Z Meeting Page 2 COMMENTS: 1. Background• The surrounding zoning and land uses are as follows: N: E-P; Vacant (Hillside at Rock Creek Preliminary P.U.D.) S: R-L-P; Vacant (Brookside at Rock Creek Preliminary P.U.D.) E: FA-1 (County); Vacant W: R-L-P; Vacant (Dusbabek Property) Stetson Creek is the same project as Brookside Village at Rock Creek P.U.D. The name was changed due to a potential copyright infringement. Brookside Village at Rock Creek P.U.D. consisted of 93 single family lots 31 acres and was approved, with conditions, on November 15, 1993. It will be recalled that the McClelland -Mail Creek channel runs west to east and divides the P.U.D. The present request, being the first filing, represents the area north of the McClelland -Mail Creek channel. The first filing does not border the existing rural lots in the Schaller and Blehm County Subdivisions. Stetson Creek P.U.D. is part of the 134 acre Rock Creek Overall Development Plan, approved November 1, 1993. The northerly portion of this O.D.P. was approved as Hillside at Rock Creek Preliminary P.U.D., also approved on November 1, 1993. 2. Conditions of Approval: At the Preliminary stage, the P & Z Board attached three conditions to the approval of Brookside Village at Rock Creek P.U.D. Two of these conditions pertained to the treatment of the fence along the southerly property line and discharge of irrigation flows from the Schaller and Blehm Subdivisions. Since Stetson Creek First Filing does not include the southern area of the Preliminary P.U.D., these two conditions will be addressed in a future filing. The remaining condition reads as follows: By the time of consideration of the Final P.U.D., the City Council shall have passed, on second reading, the request to rezone the property from T, Transition, to R-L-P, Low Density Planned Residential. The City Council passed, on second reading, the request to rezone the property to R-L-P on October 19, 1993. Stetson Creek P.U.D., First Filing - Final, #16-89F January 24, 1994 P & Z Meeting Page 3 3. Land Use: The request for single family homes is in compliance with the approved Rock Creek Overall Development Plan. The Preliminary P.U.D. was evaluated by the Residential Uses Point Chart of the L.D.G.S. The project scored 50% which allowed the overall density of 3.02 dwelling units per acre. Stetson Creek First Filing represents a dwelling units per acre. The overall represents a density of 3.02 dwelling unit 4. Design: A. Streetscape Along Stetson Creek Drive gross density of 2.94 Preliminary, however, s per acre. Stetson Creek Drive is designed so that there will be a detached meandering sidewalk, parkway strip, and street trees. This is considered a superior design than a standard attached walk with rollover curb and gutter which does not allow a parkway strip for trees. In addition, there will be two "front access drives" which will act as private driveways for a cluster of homes. This allows greater flexibility in both house and garage placement which de- emphasizes the prominence of the garage as found in most modern subdivisions. B. Streetscape Along Timberline Road There will be street trees planted in the parkway strip between the sidewalk and curb along Timberline Road. Also, there will be alternating clusters of evergreen trees and ornamental trees between the sidewalk and the rear lot lines. Fencing along Timberline Road will be six feet in height with a uniform design as per the specifications noted on the landscape plan. C. Solar orientation The overall Preliminary P.U.D. was approved with 74.19% of the total lots being in compliance with the Solar Orientation Ordinance. This exceeds the required minimum of 65%. Although the First Filing has a compliance rate of only 54%, it is part of the overall approved Preliminary P.U.D., and, therefore, does not need a variance from the Planning and Zoning Board. 0 Stetson Creek P.U.D., First Filing - Final, #16-89F January 24, 1994 P & Z Meeting Page 4 5. Transportation: Stetson Creek Drive will be constructed to the collector street standard (50 feet of pavement) from the intersection with Timberline Road to the intersection with Mountain Creek Circle. From this point eastward, the street will be downsized to a local (36 feet of pavement). The access point on Timberline conforms with the planning for the Dusbabek parcel across the street to the west. The future local street extensions to the north conform to the Preliminary P.U.D. for Hillside at Rock Creek. The proposed street network and transportation impacts have been reviewed and are found acceptable by the Transportation Department. RECOMMENDATION: In review of the request for Stetson Creek, First Filing, Final P.U.D., Staff has made the following findings of fact: A. The request satisfies the Preliminary condition of approval. B. The Final P.U.D. is in substantial conformance with the Preliminary P.U.D. C. The request conforms to the Overall Development Plan. D. The request satisfies the criteria of the L.D.G.S. Staff, therefore, recommends approval of Stetson Creek, First Filing, Final P.U.D., #16-89F with the following condition: 1. The Planning and Zoning Board approves this planned unit development final plan upon the condition that the development agreement, final utility plans, and final P.O.D., plans for the planned unit development be negotiated between the developer and City staff and executed by the developer prior to the second monthly meeting (March 28, 1994) of the Planning and Zoning Board following the meeting at which this planned unit development final plan was conditionally approved; or, if not so executed, that the developer, at said subsequent monthly meeting, apply to the Board for an extension of time. The Board shall not grant any such extension of time unless it shall first find that there exists with respect to said planned unit development final plan certain specific unique and extraordinary circumstances which require the granting of the extension in order to Stetson Creek P.U.D., First Filing - Final, #16-89F January 24, 1994 P & Z Meeting Page 5 prevent exceptional and unique hardship upon the owner or developer of such property and provided that such extension can be granted without substantial detriment to the public good. If the staff and the developer disagree over the provisions to be included in the development agreement, the developer may present such dispute to the Board for resolution if such presentation is made at the next succeeding or second succeeding monthly meeting of the Board. The Board may table any such decision, until both the staff and the developer have had reasonable time to present sufficient information to the Board to enable it to make its decision. (If the Board elects to table the decision, it shall also extend the term of this condition until the date such decision is made). If this condition is not met within the time established herein (or as extended, as applicable), then the final approval of this planned unit development shall become null and void and of no effect. The date of final approval for this planned unit development shall be deemed to be the date that the condition is met, for purposes of determining the vesting of rights. For purposes of calculating the running of time for the filing of an appeal pursuant to Chapter 2, Article II, Division 3, of the City Code, the 11final decision" of the Board shall be deemed to have been made at the time of this conditional approval; however, in the event that the dispute is presented to the Board for resolution regarding provisions to be included in the development agreement, the running of time for the filing of an appeal of such 11final decisions, shall be counted from the date of the Board's decision resolving such dispute. 0 0 ITEM: NUMBER: I P Olxun Lunyon ! olerol � o r____ 4r I STETSON CREEK PUD Final North 16-89F UN LIATTID / UNPLATTED` R 0). STETSON ((BW 0)a �\ R — 5), TRAT A YPR un R ( )vr rIe« 60 ae0 ye•. u. / ss]ilar. >m a s so R [� ] ss. 11 •AA v. \ R).\\ \ (sPR •.,m u- cape +oxsc — ffi'b' i UNPLATTED oUNPLATTED TM R•a � � O R R Y) 0. (5) UNPLATTED R P M r m! i yp I Q ] (.PR i TRACT 0 ]F (3 L UNPLATTED �[I urban design, ina. L�s0r...:v4aaw fJa])ssa-a]a iL ki \&J lVdlN\ 1ST FILING LEGEND 6(���pp • SHADE TREES ORNAMENTAL TREES M1 /� (pI (�ry�U)IN� I!—OI1V/. L 39Il E A � W.Js'3520 UNDSCAPE PLAN CONIFEROUS TREES ® IDENTITY SIGN o.TE OF FPEPARA Mw 12—a8-93 R HANDICAP RAMP oec SIONSS LOTS MEETING SOLAR ACCESS REQUIREMENT t iem- •^^ +�, �*-- o — NOTE: SHEET 2 FOR NOTES, VICINITY MAP, AND PLANT LIST — O 50 100 150 SHEET NO. 1 - 2 0 • PLANT LIST 1:74. ,.,...,,,,<,�......,.. ..M. ,. — - Dq/V`5'� I PLANT�NOWTSM_ _ — — — - ............. ....�.W.. (3)F1 d ~....e.or......... n•.. ....��........... TMCTu FF . m .r.. ..... u..mmn.�.,.�...a. x..w.....w. w..we n (3)pAu n .a re.rn..,. r.......w �.. s..mw....es.u. � EA4lrtxr T iMrGTefD w— r — as,vrt.mn IT ,\ zxG TRM / 1X4 CEDAR FICKETS / GxG WOOD COST I / \ TYPICAL FENCE ALONG TIMBERLINE ROAD AND STETSON CREEK DRIVE PRELIMINARY DESIGN NOT TO wc) p (3)Ps LE(MEMDD SHADE TREES ORNAMENTAL TREES CONIFEROUS TREES IDENTITY SIGN HANDICAP RAMP LOTS MEETING SOLAR ACCESS REQUIREMENTS LAND USE BREAKDOWN _ Mm SIGNATURE RI'OCK,x wa..+.n.. x.r.w....... Cam u,ta�a1..4.e9rsou dy Ll LCd 11®A� �+LNLCe1CeL(1� 1ST FILING ACAD 35zo52-2 PROJECT N0. 352' I�GIMD�C�G1pC� p�Q�l SCALE i•=5D DATE OF PREPAMII(Nl 12-06-93 w�c swNs� rant_ .wr r� O 50 100 190 SHEET NO. 2 OE 2 0 • STETSON CREEK, 1ST FILING PROPERTY DESCRIPTION December 6, 1993 A tract of land located in the Southwest Quarter of Section 5, Township 6 North, Range 68 West of the 6th Principal Meridian, City of Fort Collins, County of Larimer, State of Colorado, being more particularly described as follows: Considering the West line of the Southwest Quarter of said Section 5 as bearing South 00008'46" East from a 1 1 /2" Steel Rod at the West Quarter corner of said Section 5 to a No. 4 rebar with aluminum cap at the Southwest corner of said Section 5 and with all bearings contained herein relative thereto: Commencing at the West Quarter corner; thence along said West line, South 00 °08'46" East, 474.54 feet to the POINT OF BEGINNING; thence North 89051'14" East, 50.00 feet to a point on a non -tangent curve concave to the Northeast having a central angle of 89059'52", a radius of 15.00 feet and the chord of which bears South 45 °08'42" East, 21.21 feet; thence along the arc of said curve 23.56 feet; thence, North 89151'22" East, 113.75 feet to a point on a curve concave to the Northwest having a central angle of 90101'04", a radius of 15.00 feet and the chord of which bears North 44050'50" East, 21.22 feet; thence along the arc of said curve 23.57 feet; thence, South 89 ° 50'01 " East, 54.00 feet to a point on a non -tangent curve concave to the Northeast having a central angle of 84010'21 ", a radius of 15.00 feet and the chord of which bears South 42014'52" East, 20.11 feet; thence along the arc of said curve 22.04 feet; thence, South 84120'03" East, 42.10 feet to a point on a curve concave to the North having a central angle of 06041'46", a radius of 491 .00 feet and the chord of which bears South 87040'56" East, 57.35 feet; thence along the arc of said curve 57.38 feet to a point on a curve concave to the North having a central angle of 02023'13", a radius of 583.00 feet and the chord of which bears North 87046'35" East, 24.29 feet; thence along the arc of said curve 24.29 feet; thence, North 86034'58" East, 84.96 feet to a point on a curve concave to the Northwest having a central angle of 103 047'11 ", a radius of 15.00 feet and the chord of which bears North 34041'23" East, 23.61 feet; thence along the arc of said curve 27.17 feet; thence, North 86034'58" East, 56.36 feet to a point on a non -tangent curve concave to the Northeast having a central angle of 103047" 1 ", a radius of 15.00 feet and the chord of which bears South 41 031'26" East, 23.61 feet; thence along the arc of said curve 27.17 feet; thence, North 86034'58" East, 81 .01 feet to a point on a curve concave to the South having a central angle of 1 1 026'36", a radius of 637.00 feet and the chord of which bears South 87041'44" East, 127.01 feet; thence along the arc of said curve 127.22 feet to a point on a curve concave to the Northwest having a central angle of 82025'25", a radius of 15.00 feet and the chord of which bears North 56048'51" East, 19.77 feet; thence along the arc of said curve 21.58 feet; thence, South 78 ° 25' 10" East, 54.18 feet to a point on a non -tangent curve concave to the Northeast having a central angle of 83032'43", a radius of 15.00 feet and the chord of which bears South 33044'06" East, 19.99 feet; thence along the arc of said curve 21.87 feet; thence, South 75030'27" East, 183.66 feet to a point on a curve concave to the Northwest having a central angle of 90000'00", a radius of 15.00 feet and the chord of which bears North 59 ° 29'33" East, 21.21 feet; thence along the arc of said curve 23.56 feet; thence, South 75030'27" East, 54.00 feet to a point on a non -tangent curve concave to the Northeast having a central angle of 90000'00", a radius of 15.00 feet and the chord of which bears South 30030'27"East, 21.21 feet; thence along the arc of said curve 23.56 feet; thence, South 75030'27" East, 177.84 feet to a point on a curve concave to the Northwest having a central angle of 90000'00", a radius of 15.00 feet and the chord of which bears North 59129'33" East, 21.21 feet; thence along the arc of said curve 23.56 feet; thence, South 75030'27" East, 54.00 feet to a point on a non -tangent curve concave to the Northeast having a central angle of 90000'00", a radius of 15.00 feet and the chord of which bears South 30030'27" East, 21.21 feet; thence along the arc of said curve 23.56 feet; thence, South 75030'27" East, 233.31 feet to a point on a curve concave to the Northwest having a central angle of 90000'00", a radius of 15.00 feet and the chord of which bears North 59029'33" East, 21.21 feet; thence along the arc of said curve 23.56 feet; thence, South 75030'27" East, 54.00 feet to a point on a non -tangent curve concave to the Northeast having a central angle of 90000'00", a radius of 15.00 feet and the chord of which bears North 30030'27" West, 21.21 feet; thence along the arc of said curve 23.56 feet; thence, South 75030'27" East, 52.67 feet to a point on a curve concave to the North having a central angle of 05042" 2", a radius of 473.00 feet and the chord of which bears North 78021'33" West, 47.06 feet; thence along the arc of said curve 47.08 feet; thence, South 08047'21" West, 54.00 feet; thence, South 06033'45" East, 111.51 feet; thence, South 21 040" 2" East, 65.85 feet; thence, South 30018'32" East, 81.62 feet; thence, South 42 °44' 17" East, 81.62 feet; thence, South 56 ° 17' 18" East, 81.46 feet; thence, South 17031'58" West, 20.00 feet; thence, North 72028'02" West, 683.52 feet; thence, South 86034'58" West, 1202.03 feet; thence, North 80032'27" West, 95.74 feet to a point on the West line of said Southwest Quarter; thence along said West line, North 00008'46" West, 531.51 feet to the Point of Beginning. The above described tract of land contains 18.292 acres and is subject to all easements and rights -of -way now on record or existing. so N STETSON CREEK FINAL PUD LAND USE BREAKDOWN DECEMBER 6,1993 Area Gross 740,085 sq.ft. 16.99 acres Net 576,820 sq.ft. 13.24 acres Dwelling Units Single Family 50 units Other 0 units TOTAL UNITS 50 units Solar Oriented Lots 27 units 54.00% Density Gross 3.02 du/ac Net 4.08 du/ac Coverage Buildings 115,000 sq.ft. 15.54% Street R.O.W. 163,265 sq.ft. 22.06% Parking & Drives 2,750 sq.ft. 0.37% Open Space: Common 139,314 sq.ft. 18.82% Private 319,756 sq.ft. 43.21 % TOTAL OPEN SPACE 459,070 sq.ft. 62.03% Floor Area Residential 130,000 sq.ft. Minimum Parking Provided Garage/Carport 100 spaces Other 0 spaces TOTAL VEHICLES 100 spaces 2 spaces/unit *note: Garages and/or driveways will accomodate handicap, motorcycle, and bicycle parking Maximum Building Height 36 ft. Setbacks (unless otherwise noted) Front* 20 ft. Side 5 ft. Corner Side 15 ft. Rear 15 ft. *note: 15' at Lots 44, 47, 48, and 50 n the 1st Filing; Garage doors to be 20' minimum from private drives 0 • SCHOOL PROJECTIONS PROPOSAL: STETSON CREEK PUD - Final DESCRIPTION: 50 single family units on 16.9 acres DENSITY: 2.94 du/acre General Population 50 (units) x 3.5 (persons/unit) = 175 School Age Population Elementary - 50 (units) x .450 (pupils/unit) = 22.5 Junior High - 50 (units) x .210 (pupils/unit) = 10.5 Senior High - 50 (units) x .185 (pupils/unit) = 9.25 Design Affected Schools Capaefty Enrollment Timnath Elementary 546 537 Boltz Junior High 900 1015 Fort Collins Senior High 1300 1418 STETsed Activity A: ALL CRITERIA CRITERION ALL DEVELOPMENT CRITERIA Al. COMMUNITY -WIDE CRITERIA 1.1 Solar Orientation 1.2 Ccmprehensive Plan 1.3 Wildlife Habitat 1.4 Mineral Deposit 1.5 Ecologically Sensitive Areas 1.6 Lands of Agricultural Importance 1.7 Enercv Conservation 1.8 Air Quality 1.9 Water Qualitv APPLICABLE CRITERIA ONLY the erdenon Wiu the ad appiicabie7 be satisfied? A 2. NEIGHBORHOOD COMPATIBILITY CRITER 2.1 Vehicular. Pedestrian, Bike Transoortation 2.2 Building Placement and Orientation 2.3 Natural Features 2.4 Vehicular Circulation and Parking 2.5 Emergency Access 2.6 Pedestrian Circulation I I✓ 2.7 Architecture 2.8 Building Height and Views 2.9 Shading 2.10 Solar Access 2.11 Historic Resources 2.12 Setbacks 2.13 Landscape V/ 2.14 Sians 2.15 Site Lighting 2.16 Noise and Vibration 2.17 Glare or Heat 2.18 Hazardous Materials A 3. ENGINEERING CRITERIA If no, please explain 3.1 Utility Capacity Iv/ 3.2 Design Standards 3.3 Water Hazards 3.4 Geologic Hazards 54