Loading...
HomeMy WebLinkAboutKUM & GO #0951 - PDP210013 - SUBMITTAL DOCUMENTS - ROUND 1 - SUPPORTING DOCUMENTATIONCompany:Company: Contact Name:Contact Name: Phone:515.457.6232 Phone: Email:Ryan.Halder@kumandgo.com Email: 1. Fill in the yellow fields in Microsoft Excel. 2. Print and have the Design Engineer stamp the form. Project Name: Project Address or Subdivision: Planning & Zoning # or Building Permit # (if known):Date: Type:Meter Type: Meter/Tap Size: Existing Fixture + Proposed Fixtures - Fixtures Removed = Total Fixtures x Fixture Unit Values = Total Fixture Unit Values Enter Qty Enter Qty Enter Qty Qty Load Values Load Values 0 3.60 0.00 0 8.00 0.00 0 1.40 0.00 0 4.00 0.00 0 2.00 0.00 0 3.00 0.00 0 1.40 0.00 0 0.25 0.00 0 1.40 0.00 0 4.00 0.00 0 1.40 0.00 0 0.70 0.00 4 4 2.00 8.00 2 2 3.00 6.00 0 4.00 0.00 0 1.40 0.00 0 10.00 0.00 2 2 5.00 10.00 0 3.00 0.00 0 1.40 0.00 0 3.00 0.00 0 4.00 0.00 0 6.00 0.00 0 2.20 0.00 5 5 10.00 50.00 0 5.00 0.00 0 2.00 0.00 4 4 10.00 40.00 Other:4 4 2.00 8.00 Other:1 1 2.00 2.00 1 1 4.00 4.00 1 1 1.00 1.00 4 4 0.50 2.00 Supply system is predominately for:131.00 (Per values in the 2018 IPC Table E103.3(3) included on page 2 of this form.) Fixture Count Flow (GPM)50.5 Will there be Irrigation?Yes Is building occupied 24/7?Yes Irrigation Flow (GPM)37.5 Is there a swimming pool?No (Irrigation flow is included in the total flow calculation.)Total Flow (GPM)*: 88.0 Lavatory (Public / Faucet) Service Sink (Offices, Etc. / Faucet) Shower Head (Public / Mixing Valve) Bathtub Only (Public / Faucet) Bidet (Private / Faucet) Combination Fixture (Private / Faucet) Dishwashing Machine (Private / Automatic) Drinking Fountain (Offices, etc. / 3/8" valve) Kitchen Sink (Private / Faucet) *Total flow should include all water uses (indoor, irrigation, swimming pool makeup water, etc.). Irrigation supplied off a meter to residential structures (multi- family and mixed use) and commercial structures occupied 24/7 must be included in total flow. Commercial structures not occupied 24/7 may exclude irrigation flow from the total flow calculation. Notes: Irrigation provided by separate tap Water Closet (Public / Flushometer Valve) Water Closet (Public / Flush Tank) Water Closet (Public or Private / Flushometer Tank) Shower Head (Private / Mixing Valve) Urinal (Public / 1" flushometer valve) Urinal (Public / 3/4" flushometer valve) Urinal (Public / 3/4" flush tank) Washing Machine - 8 lb (Private / Automatic) Washing Machine - 8 lb (Public / Automatic) Kitchen Sink (Hotel, Restaurant / Faucet) Laundry Trays - 1 to 3 (Private / Faucet) Lavatory (Private / Faucet) 2020 WATER METER JUSTIFICATION LETTER • 2018 International Plumbing Code Values Ryan Halder 1.5" WATER FIXTURE COUNTS & VALUES • Load Values from 2018 IPC Table E103.3(2) Fixture Type (Occupancy/Supply Control Type) Bathroom Group (Private / Flush Tank) Bathroom Group (Private / Flushometer Valve) Bathtub Only (Private / Faucet) WATER SERVICE (Tap, service and meter must be the same size.): Commercial Design Engineer Contact InfoCustomer Contact Info Erica Morton 707-419-9988 emorton@olsson.com Kum & Go LC Olsson Design Engineer Stamp Project Info Lot 5 East Acres (KG 951) 949 E. Prospect Road Sensus Omni C2 (1.5" and larger) Please reference the "Max Flow Rate per Meter" table on page 2. Other: Other: Other: Other: Instructions: Please contact Blake Hornung at (970) 962-3749 with questions. Water Demand Fixture Unit Total:Flush Tanks Washing Machine - 15 lb (Public / Automatic) Water Closet (Private / Flushometer Valve) Water Closet (Private / Flush Tank) Page 1 of 2 Supply Systems Predominately for:Meter Size Max Flow Rate Water Supply Fixture Units Inches GPM 1 3/4"30 2 1" 50 3 1.5" 100 4 2" 160 5 3" 400 6 4" 800 7 6" 1600 8 9 10 11 12 13 14 15 16 17 18 19 20 25 30 35 40 45 50 60 70 80 90 100 120 140 160 180 200 225 250 275 300 400 500 750 1000 1250 1500 1750 2000 2500 3000 4000 5000 Source: 2018 International Plumbing Code, Appendix E Sizing of Water Piping System, Table E103.3(3) 325.0 297.0 269.0 32.0 95.5 101.0 104.5 108.0 127.0 143.0 67.5 73.0 77.0 81.0 85.5 90.0 48.0 50.0 54.0 58.0 61.2 64.3 34.2 35.0 38.0 42.0 44.0 46.0 593.0 Gallons per Minute - - - - 15.0 17.4 269.0 297.0 325.0 380.0 433.0 525.0 85.0 105.0 124.0 170.0 208.0 239.0 57.0 61.0 65.0 70.0 75.0 80.0 35.0 38.0 41.0 43.5 48.0 52.5 23.3 24.9 26.3 27.7 29.1 18.4 18.8 19.2 19.6 21.5 380.0 433.0 525.0 593.0 170.0 208.0 239.0 30.2 31.0 31.8 32.6 33.4 19.8 22.2 24.6 27.0 27.8 28.6 29.4 Flushometer Valve Demand 14.6 15.4 16.0 16.5 11.8 12.8 18.0 17.0 17.5 13.7 Gallons per Minute 3.0 5.0 6.5 Flush Tank Demand Flow (GPM) Based on Water Supply Fixture Units Max Flow Rate per Meter Source: 10th Edition of the City of Loveland Water and Wastewater Development Standards Approved August 2007, Section 4.4.6.E.3. 8.0 9.4 10.7 Page 2 of 2