Loading...
HomeMy WebLinkAboutMAVERIK - FDP210003 - SUBMITTAL DOCUMENTS - ROUND 4 - PLANS6815COTG2RD4"12114"ODDS122"G79144102"CW5161"CW1500 GALLON GREASEINTERCEPTORSAMPLING MANHOLETO CITYSEWERSYSTEM2COTG1P154"4"3COTG24"GR3"V132COTG(2)2"V3COTG23"V2"VPIPE SPECIFICATIONS2. WASTE & VENT,4. CONDENSATE DRAINS:3. GAS RAIN WATERBELOW GRADE:1. DOMESTIC WATER:TYPE 'K' SOFT COPPER BELOW FLOOR OR GRADE w/ WROUGHT COPPER FITTINGS (BRAZED). TYPE 'L' HARD DRAWN COPPER TUBING w/ WROUGHT COPPER (95/5 SOLDER). FITTINGS ABOVE FLOOR OR GRADE.3/4" - 2 1/2" TYPE "K" SOFT COPPER 3" + DUCTILE IRON OR PVC CONFORMING TO AWWA STANDARDSSERVICE WEIGHT NO-HUB CAST IRON w/ MG' OR 'IDEAL' FITTINGS. SCHEDULE 40 GALV. STEEL FOR EXPOSED VENT LINES. ALL DRAINS & TRAPS TO BE CAST BRASS, CAST IRON OR GALV, STEEL. PLASTIC PIPING CONFORMING TO IAPMO AND ASTM SPECIFICATIONS IS ACCEPTABLE WHERE PERMITTED BY LOCAL CODES. NO PLASTIC PIPE ISPERMITTED IN RETURN PLENUM ATTIC.SCHEDULE 40 BLACK STEEL w/ BLACK MALLEABLE IRON SCREWED FITTINGS, OR WELD FITTINGS.TYPE 'L' HARD DRAWN COPPER w/ WROUGHT COPPER SOLDER JOINT FITTINGS. WALK-IN COOLERS/FREEZERS: MINIMUM OF TYPE M COPPER PIPE WITH 95/5 SOLDER FITTING AND MEET NSF STANDARDS.NO COMBUSTIBLE PIPING OR MATERIAL SHALL BE RUN IN RETURN AIR PLENUM SPACE ABOVE CEILING. ALL UNDERGROUND WATER PIPING SHALL BE WRAPPED &/OR INSULATED PER SPECIFICATIONS.8"SD8"WGSAN4"8"WATER MOTOR GONGWMGPOST INDICATOR VALVEPOINT OF CONNECTIONUTILITY WATER MAIN - SIZEUTILITY GAS MAIN - SIZEFIRE SPRINKLER ZONE VALVEUTILITY STORM DRAIN - SIZESANITARY SEWER MAIN - SIZESDFSZVWGSANPIVPOCPIPE RISER UP (VIEWED CEILING TO FLOOR)'Y' STRAINERPRESSURE GAUGECHECK VALVEFIRE DEPT. CONNECTIONLIQUID PROPANE LINEFIRE HYDRANTWATER METERGAS METERSHUT-OFF VALVE / GATE VALVESHUT-OFF VALVE / BALL VALVESOV / GV (NORMALLY CLOSED)SOV / BV (NORMALLY CLOSED)SHUT-OFF VALVE /GAS COCKPRESSURE REGULATING VALVETEMP. & PRESS. RELIEF VALVERAIN WATER LINE (ABOVE FLOOR)SHUT-OFF VALVE IN YARD BOXPIPE RISER DOWN (VIEWED CEILING TO FLOORPRVSOV IN YBFHFDCRWLPPR GAWTR MTRGAS MTRT&PSTRSOV / GV (NC)SOV /BV (NC)ABBREVIATIONSOV / BVSOV / GCCK VUNSOV / GVDNUPUNIONDESCRIPTIONPLUMBING SYMBOL SCHEDULESYMBOLNOTE: FOR PIPE SIZES 1 1/4" & SMALLER, USEINSULATION SIZED FOR A 1/4" LARGER PIPE TO ALLOWROOM FOR INSULATION OVER HEAT TRACE CABLE.NOTE: ALL UNDERGROUND AIR, HOT & COLD WATER, HOT WATER RETURN & SUPPLY, REFRIGERANT,STEAM & CONENSATE PIPING TO BE INSULATED, ALSO SEE SPECIFICATIONS.INSULATION SCHEDULE(° F)40° - 180°40° - 180°FLUID TEMP.RANGE100° - 140°35° - 140°35° - 100°REFRIGERANTDOMESTIC HOT & COLD WATER ABOVE FLOORDOMESTIC HOT & COLD WATER BELOW SLABROOF DRAIN & OVERFLOW DRAINHEAT TRACED DOMESTIC HOT WATER ABOVE FLOORSYSTEM TYPE1/2" ARMAFLEX OR IMCOA1/2" - 1"2"1 1/4" - 1 1/2"PIPE SIZES1"1 1/2"2"FIBERGLASS INS. THICKNESSFIBERGLASS w/ VAPOR BARRIER1/2" ARMAFLEX OR IMCOAINSULATION TYPEDOMESTIC HOT WATER ABOVE FLOOR WITH HEAT TRACEDOMESTIC COLD WATER ABOVE FLOORALL1"ROOF DRAIN & OVERFLOW DRAIN ABOVE FLOORALL1"FIBERGLASS w/ VAPOR BARRIER2 1/2"2 1/2"3" OR LARGERSAME SIZE AS PIPE1/2" - 1"2" OR LARGER1 1/4" - 2"1"1 1/2"2"DOMESTIC HOT WATER ABOVE FLOOR WITHOUT HEAT TRACEP1REFERENCE SYMBOL LEGENDAP-31P-311100RT11K1KEY NOTE SYMBOLSPECIAL NOTE SYMBOLREFERENCEMECHANICAL EQUIPMENT SYMBOL(EXAMPLE: DETAIL 1, SHEET P-3)SECTION SYMBOL(EXAMPLE: NOTE #1)(EXAMPLE: NOTE #1)DETAIL SYMBOLSYMBOL(EXAMPLE: NOTE #1)(EXAMPLE: ROOM #100)GENERAL NOTE SYMBOL(EXAMPLE: ITEM K-1)ROOM NUMBER SYMBOLPLUMBING EQUIPMENT SYMBOL(EXAMPLE: FIXTURE #1)OWNER SUPPLIED EQUIPMENT SYMBOL(EXAMPLE: ROOFTOP UNIT #1)(EXAMPLE: SECTION A, SHEET P-3)HEATERMAXIMUMINVERT ELEVATIONINDIRECT WASTEMANHOLEPSI LOSSREQUIREDVELOCITYMECHANICALMECHANICAL CONTRACTORREGULATORROOF DRAINPOUNDS PER SQUARE INCHOVERFLOW DRAINNOT IN CONTRACTPOINT OF CONNECTIONPOST INDICATOR VALVEPLUMBING CONTRACTORVENT THRU ROOFROUGH-IN AND CONNECTTHOUSAND BTU'S PER HOURVTRVELODPCPOCPIVPSIPSILREGSTARI & CREQ'DRDSTATIONMAXMBHMECHMCMINMHNIC(N)IWIENEWMINIMUMAVERAGECLEANOUTCONCRETECONTINUEDELEVATIONEXISTINGEXISTINGAIR CONDITIONINGDESCRIPTIONCATCH BASINCONTRACTORCENTERLINECUBIC FEET PER HOURBRITISH THERMAL UNITSBACKFLOW PREVENTERAUTOMATIC SPRINKLER RISERDOWNSPOUTCLEANOUT TO GRADEELECTRICAL CONTRACTORHOSE BIBBHUB DRAINFLOOR DRAINEXISTING TO BE REMOVEDFLOOR CLEANOUTFE & CABINETFIXTURE UNITFEET OF HEADFLOOR SINKGALLONS PER MINUTEGENERAL CONTRACTORFLOOR HOSE BOXFLUE THRU ROOFFEET PER SECONDFIRE HOSE AND CABINETFIRE EXTINGUISHERFLOORFLFT.HDFPSGCHBGPMHDHTRFTRGRFUFSGRADEELEV(E)EXISTFCOFECFHCFHB(ER)FEFDECBTUCFHCOCONCCOTGCONTRCONT'DDSDNCLCBDOWNAVGASRA/CBFPSYMBOLWALL FAUCETWALL CLEANOUTw/WCOWTRWFWATERWITHABBREVIATION SCHEDULEP-2.1P-1.0P-2.0P-2.2P-2.3LIST OF PLUMBING PLANSPLUMBING COLD & HOT WATER PLANPLUMBING SITE PLANPLUMBING WASTE & VENT PLANPLUMBING FILTERED WATER PLANPLUMBING HEAT TRACE & GAS PLANP-3.0P-3.1P-3.2PLUMBING ISOMETRICS & ROOF DRAINSPLUMBING DETAILSPLUMBING NOTES, SCHEDULES & DETAILSP-3.3EQUIPMENT SCHEDULE & PLUMBING DETAILSP-2.3APLUMBING 2 PSI GAS, HW RECIRC. PLAN & PEX PIPING ALTERNATE6'-6" MAX.5'-0"3"6"TROUGH4"2"SLOPE 1/2"/FTTROUGH: 1/2 OF THE DIAMETER OF INLET PIPE = DEPTH AND THE WIDTH SAME AS INLET PIPE DIAMETER6" BED 0F 1" CLEANANGULAR GRAVEL#4 BAR 12" O.C. BOTHWAYS BOTTOM & SIDESSLOPE PAVEMENT AWAYFROM MANHOLES20' X 12' X 6'REINFORCEDCONCRETE PADC.I. MANHOLE COVER AND RING(TYP. OF 1), PATTERN TO SUITLOCAL STANDARDS. (EXTRA HEAVYDUTY TRAFFIC)REINFORCED CONCRETEEXTENSIONS (24" DIA,)#4 BAR 12" O.C. LONG.#6 BAR 6" O.C. LAT.ENTIRE LENGTH OF COVERNOTE:PROVIDE ONE SAMPLING MANHOLE 3' TO 7' DEEP. MUST BE INSTALLED INACCORDANCE WITH LOCAL REGULATIONS. IF DEEPER MANHOLE REQUIRED, VERIFY WITH THE LOCAL AUTHORITY. NOTES:1. PREFABRICATED UNIT SUCH AS AMCOR OR SITE-BUILT OF SIMILAR CONSTRUCTION AND CAPACITY ARE ACCEPTABLE. PROVIDE SHOP DRAWINGS PRIOR TO ORDERING. 1,500 GALLON/MIN.2. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO ADMINISTRATIVE AUTHORITIES FOR APPROVAL PRIOR TO ORDERING OR FABRICATING. EODNEAROLOCIGNELAOISSEFDERETSIGER NORP R27241A.NIEL SONGORDON PROJECT NUMBER:185 S. State Street | Salt Lake City, Utah 84111SHEET NUMBERSHEET NAMEDRAWN BY:APPROVED BY:DRAWING ISSUEPROTOTYPE VERSION:THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC.DESCRIPTIONARCHITECT:ENGINEER:STAMP:ISSUANCEDATEConsulting EngineersThis document and the ideas and designs incorporated herein, as an instrument of professional service, is the property of NIELSON ENGINEERING, INC. and is not to be used, in whole or in part,for any other project without the written authorization of an authorized representative of NIELSON ENGINEERING, INC. Unauthorized use will be prosecuted to the fullest extent of the Law.Copyright c 2021 by: NIELSON ENGINEERING, INC.Nielson Engineering, Inc.OWNERSHIP OF DOCUMENTS156 North Twelfth AvenuePocatello, Idaho 83201PHONE (208) 232-2577FAX (208) 234-09184/30/2021 1:54:50 PMPLUMBING SITEPLAN19335PERMIT SET4/30/21BHApproverP-1.0MAVERIK, INC.I-25 & E. COUNTY ROAD 32FT COLLINS, COMAVERIK C-STORE1/16" = 1'-0"P-1.01PLUMBING SITE PLANNP-1.0 KEY NOTES1 PLUMBING CONTRACTOR IS TO STUB BUILDING SEWER AND BUILDING GREASE WASTELINES 5'-0" OUT PAST THE DISCHARGE POINT OF THE GREASE INTERCEPTOR.CONNECT THE BUILDING SEWER LINE INTO THE DISCHARGE LINE FROM THE GREASEINTERCEPTOR AND THEN THIS LINE WILL RUN OUT TO THE CITY SEWER SYSTEM. THEP.C. SHALL FIELD VERIFY THE LOCATION AND THE INVERT OF THE BUILDING SEWERLINE BROUGHT TO WITHIN 5'-0" OF THE GREASE INTERCEPTOR BY THE SITECONTRACTOR. THE SITE CONTRACTOR SHALL PAY ALL CONNECTION FEE'S NEEDEDTO CONNECT TO THE BUILDING SEWER LINE TO THE CITY SEWER UTILITIES.2 INSTALL A C.O.T.G. ON THE BUILDING GREASE, ROOF DRAIN AND SEWER LINES ASSHOWN ON THE DRAWINGS. RISE EACH C.O.T.G. LEVEL WITH FINISH GRADE. INSTALLA NICKEL BRONZE CLEANOUT (J.R. SMITH 4220) ON EACH RISER. POUR A 16" X 16" x 4"CONCRETE PAD AROUND EACH CLEANOUT, UNLESS THE CLEANOUT IS LOCATED IN ASIDEWALK OR DRIVEWAY.3 SEE SHEET P-2.0 FOR CONTINUATION OF THE BUILDING DRAIN LINES INSIDE OF THEBUILDING.4 PLUMBING CONTRACTOR IS TO RUN 5'-0" OUTSIDE OF HOUSEKEEPING PAD TOCONNECTION ONTO THE NEW BUILDING WATER SERVICE BROUGHT TO THISLOCATION BY THE SITE CONTRACTOR. IF BACKFLOW PROTECTION IS REQUIREDINSIDE OF BUILDING, THE P.C. SHALL PROVIDE AND INSTALL THE BACKFLOW DEVICE.THE SITE CONTRACTOR SHALL PROVIDE THE NEW WATER SERVICE TO 5'-0" OUTSIDEOF HOUSEKEEPING PAD, NEW WATER METER WITH ACCESSORIES (IF REQUIRED), ALLBACKFLOW PROTECTION (IF REQUIRED TO BE OUTSIDE OF BUILDING) AND PAY ALLCOSTS AND FEES ASSOCIATED WITH THE CONNECTION OF THIS WATER SERVICE TOTHE LOCAL WATER PROVIDER WATER SYSTEM. KEEP THE WATER LINES 1'-0" BELOWTHE FROST LEVEL AT ALL TIMES.5 SEE SHEET P-2.1 FOR CONTINUATION OF THE WATER LINES INSIDE OF THE BUILDINGAND THE COMPLETE BUILDING WATER SYSTEM.6 THE LOCAL GAS UTILITY COMPANY SHALL PROVIDE THE GAS SERVICE TO THEBUILDING. PROVIDE GAS LINE PRESSURE OF 6 TO 11 INCHES OF WATER COLUMN, THEGAS METER, AND GAS METER POST. THIS EXISTING OR UPGRADED SERVICE SHALLPROVIDE GAS TO ALL THE GAS APPLIANCES IN THE BUILDING.7 THE GAS CONTRACTOR SHALL CONNECT ONTO THE DISCHARGE SIDE OF THE GASMETER OUTSIDE OF THE BUILDING AT THIS APPROXIMATE LOCATION.8 THE GAS CONTRACTOR SHALL RUN THE GAS PIPING FROM THE DISCHARGE SIDE OFMETER TO EACH GAS APPLIANCE INSIDE OF BUILDING (NFPA 54). PROVIDE AT EACHPIECE OF EQUIPMENT AS GAS SHUTOFF VALVE, 6" DIRT LEG, AND UNION. HARD PIPEALL GAS APPLIANCE.9 THE GAS CONTRACTOR SHALL PAINT ALL EXPOSED GAS PIPING WITH ONE COAT OFPRIMER AND ONE COAT OF PAINT. LABEL EACH PIECE OF EQUIPMENT, TO IT'SFUNCTION AND IT'S LOAD.10 THE 2" DOMESTIC WATER SERVICE LINE SHALL BE ENCASED IN A PIPE SLEEVE (4"MINIMUM SIZE PIPE, PVC OR ABS), FROM 18" OUT PAST THE HOUSEKEEPING PAD TO AMINIMUM OF 6" ABOVE THE SLAB INSIDE OF THE BUILDING. THE JOINTS IN THE SLEEVESHALL BE SEALED TIGHT. SEE DETAIL FOR MORE INFORMATION.11 THE P.C. SHALL PROVIDE A J. R. SMITH 1770 DOWNSPOUT NOZZLE WITH RING ON THEOVERFLOW DRAIN ON THE OUTSIDE OF THE BUILDING. SEAL ALL PENETRATIONSTHRU OUTSIDE BUILDING WALL WEATHER-TIGHT. SECURE THE RING TO THEBUILDING.12 SEE SHEET P-3.2 (PLUMBING ROOF DRAIN PLAN) FOR THE LOCATIONS OF THE ROOFDRAINS AND OVERFLOW DRAINS. OVERFLOW DRAINS WILL DAYLIGHT HIGH THRU THEEXTERIOR WALL/PARAPET OR LOW (18" A.F.G.) THRU THE EXTERIOR WALL. THE ROOFDRAINS WILL DROP DOWN THRU THE BUILDING SLAB AND OUT TO THE STORM SEWERPROVIDED BY THE SITE CONTRACTOR.13 RUN THE GREASE INTERCEPTOR VENTS UNDERGROUND TO INSIDE OF THE BUILDINGAND CONNECT TO THE BUILDING VENTING SYSTEM. THESE LINES SHALL BESEPARATE LINES COMING INTO THE BUILDING, THEY MAY BE CONNECTED TOGETHERABOVE THE CEILING OF THE BUILDING. PROVIDE 2" VENT LINE (INSIDE OF TANK) AND3" VENT LINE (VENT THE SYSTEM).14 THE GAS CONTRACTOR SHALL PROTECT THE GAS LINE/GAS METER AGAINST DAMAGE.IF REQUIRED BY LOCAL AUTHORITY, PROVIDE MINIMUM 4" STEEL BOLLARDS ON EACHSIDE OF THE GAS METER ASSEMBLY.15 THE P.C. SHALL RUN THE ROOF DRAIN PIPING IN WALL OR FURRED SPACE DOWNTHRU THE BUILDING SLAB ON THE INTERIOR OF THE BUILDING AND RUN THE PIPINGHORIZONTALLY (1/8"/FT. SLOPE) OUT TO CONNECT ONTO THE BUILDING STORMSEWER PROVIDED BY THE SITE CONTRACTOR. PROVIDE A C.O.T.G. JUST OUTSIDE OFTHE BUILDING. THE SITE CONTRACTOR SHALL PROVIDE A STORM SEWER ORRETENTION POND FOR THE STORM WATER. FIELD VERIFY ALL INVERTS ANDLOCATIONS BEFORE RUNNING ANY PIPE ON THE INSIDE OF THE BUILDING.16 THE P.C. SHALL PROVIDE A 1" WATER LINE FROM INSIDE THE BUILDING FOR POSTHYDRANT. THE WATER LINE SHALL BE STUBBED OUT TO 5'-0" OUTISDE OF THEBUILDING FOR FUTURE CONNECTION BY THE SITE CONTRACTOR. THE 3" DOMESTICWATER SERVICE LINE SHALL BE ENCASED IN A PIPE SLEEVE (4" MINIMUM SIZE PIPE,PVC OR ABS), FROM 18" OUT PAST THE HOUSEKEEPING PAD TO A MINIMUM OF 6"ABOVE THE SLAB INSIDE OF THE BUILDING. THE JOINTS IN THE SLEEVE SHALL BESEALED TIGHT. SEE DETAIL FOR MORE INFORMATION.SCALE:NONEP-1.0SAMPLING MANHOLE DETAIL2 FS111110P8513821(2)1849572.172.19C9CP851P85120A17AFS2P919FS2FS1P7P12P1043AP5FD1FD1FD1FS1FD14" VTR1"C1"C1"C1"C1"C1"C1"C1"C1"C3"3"56789101517181920212224263"GR4"GR4"GR3"GR3"GR2"GR2"GR3"V2"V2"V2"V3"V2"V2"VCOTG4" CO111112121314161717191927RETAIL10130° BEER COOLER11435° BEVERAGE COOLER115COFFEE PREP111STORAGE110MEN'S105-10° FREEZER11935° STOR. COOLER118KITCHEN SERVICE11314331415FURRED SPACEPROVIDEDBY ARCHITECTRDODDSWOMEN'S106OFFICE10217171717251"C1919FS1P851232"V2"V4" VTR163"V3"VFD11"C1"C1"C1"C4"4"3"3"15COTG34"COTG3121316FS13"GR4"6"1 1/2"V2"V2"2"V4"V3"VFCO3"GR4"GR1"C1"C3"GR3"GR3"GR8231717171918P13P14P17FD23"GRA2345BCDEE1P1P2P32"V3"V4"P42"V2"V2"V1 1/2"VFS11 1/2"V4"GRFD13"GR3"GR3"GR3"GR4"2"2"V3"GR3"GR3"GR3"GR3"GR3"GR3COTG3253"GR2"GR2"GR1 1/2"VFS1TO CITY SEWER SYSTEM, BY SITE CONTRACTOR TO THIS LOCATION.1TO GREASEINTERCEPTOR2G.I. MUST BE 10'-0"MINIMUM FROM BUILDINGNOTE:SEE SHEET P-1.0FOR EXACT LOCATIONOF GREASE INTERCEPTOR& SAMPLING MANHOLE114P5P1P2P2P23"V4"3"V2"V4"3"V6COTG(2)33"V2"V3"V3"VCOTG(2)3COTG(2)34"TO GREASEINTERCEPTOR43" VTR164"COTG312112" CO2" CO2"V2"V1 1/2"V2"V967GENERAL WASTE & VENT NOTESRISE UP 6" ABOVE THE FLOOD RIM OF THE HIGHEST FIXTURE BEFORE RUNNING VENT LINES HORIZONTALLY. RISE UP WITH A VENT LINE FROM ALL FIXTURES. COMBINE VENTS TOGETHER AND THEN RISE UP TO THE ROOF.SLOPE BUILDING SANITARY WASTE LINES IN THE BUILDING AT A 1/4" TO THE FOOT. THE P.C. MAY RUN 4" AND LARGER AT 1/8" TO THE FOOT WITH THE APPROVAL OF THE BUILDING INSPECTOR. FIELD VERIFY THE INVERT OF THE BUILDING SEWER BEFORE RUNNING ANY PIPING INSIDE OF THE BUILDING.PROVIDE WALL & FLOOR CLEANOUTS AS PER CODE REQUIREMENTS WITH (WALL) S.S. OR BRASS C.O. WALL COVERS, BRASS SCREWS, & FLUSH WITH FINISHED WALL. SEE DETAIL.HANG ALL WASTE AND VENT LINES, AS SHOWN, WITH CLEVIS HANGERS, ALL THREAD ROD AND SIDE BEAM ATTACHMENTS OR EPOXY COATED UNISTRUT CHANNEL WITH CLAMPS. KEEP THE PIPING AS TIGHT AS POSSIBLE TO THE TRUSSES TO PROVIDE ROOM FOR THE OTHER TRADES AND WASTE LINES.1234PROVIDE & INSTALL TRAP PRIMER OR TRAP GUARD ON ALL FLOOR DRAINS & SINKS. ALL FLOOR DRAINS & SINKS SHALL HAVE DEEP SEAL P-TRAP INSTALLED ON THE DISCHARGE SIDE OF THE FLOOR DRAIN & SINK. TRAP SEAL DEVICE: J.R. SMITH 2692 OR PROSET TRAP GUARDS.5THE P.C. SHALL PROVIDE AND INSTALL A FULL SIZE DRAIN ON ALL BACKFLOW DEVICES. PROVIDE AND INSTALL THE PROPER AIR GAP AND A FULL SIZE DRAIN TO AN APPROVED DISCHARGE RECEPTACLE.9THE PLUMBING CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE THE INSTALLATION OF ALL FLOOR DRAINS, FLOOR SINKS AND TRAP PRIMERS. SEE THE DIMENSIONS ON THE ARCHITECTURAL SHEET A1.0 FOR THE EXACT LOCATION OF EACH OF THESE DRAINS. IF ANY DISCREPANCIES OCCUR THE ARCHITECT SHOULDBE CONTACTED IMMEDIATELY.10ALL DRAINS FROM THE ICE MAKER AND THE STORAGE BINS SHALL BE A MINIMUM OF 3/4", NO EXCEPTIONS.11ALL FLOOR SINKS AND FLOOR DRAINS IN THE BUILDING SHALL HAVE AN INDIVIDUAL P-TRAP AND BE VENTED TO THE BUILDING VENT SYSTEM.6INDIRECT WASTE THE EACH PIECE OF KITCHEN EQUIPMENT TO THE NEAREST FLOOR SINK. SEE THE CONVENIENCE STORE EQUIPMENT SCHEDULE ON SHEET P 2.1.7P.C. SHALL ROUTE ALL DRAIN LINES FROM THE KITCHEN EQUIPMENT, ICE BINS, & ETC. TO INDIRECT WASTE INTO A FLOOR SINK W/AIR GAP. THE P.C. SHALL COORDINATE THESE DRAINS WITH KITCHEN EQUIPMENT SUPPLIER AND INSTALLER.8CONNECT THE BUILDING VENTS TOGETHER HORIZONTALLY INSIDE THE BUILDING AND THEN RISING UP WITH A BUILDING VENT THRU THE ROOF. THE VTR'S SHALL RISE TO THE HEIGHT OF THE PARAPET WALL ON THE ROOF. SECURE ALL VENT PIPING.12EODNEAROLOCIGNELAOISSEFDERETSIGER NORP R27241A.NIEL SONGORDON PROJECT NUMBER:185 S. State Street | Salt Lake City, Utah 84111SHEET NUMBERSHEET NAMEDRAWN BY: APPROVED BY:DRAWING ISSUEPROTOTYPE VERSION:THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC.DESCRIPTIONARCHITECT:ENGINEER:STAMP:ISSUANCEDATEConsulting EngineersThis document and the ideas and designs incorporated herein, as an instrument of professional service, is the property of NIELSON ENGINEERING, INC. and is not to be used, in whole or in part,for any other project without the written authorization of an authorized representative of NIELSON ENGINEERING, INC. Unauthorized use will be prosecuted to the fullest extent of the Law.Copyright c 2021 by: NIELSON ENGINEERING, INC.Nielson Engineering, Inc.OWNERSHIP OF DOCUMENTS156 North Twelfth AvenuePocatello, Idaho 83201PHONE (208) 232-2577FAX (208) 234-09184/30/2021 1:54:58 PMPLUMBING WASTE& VENT PLAN19335PERMIT SET 4/30/21BH ApproverP-2.0MAVERIK, INC.I-25 & E. COUNTY ROAD 32FT COLLINS, COMAVERIK C-STORE1/4" = 1'-0"P-2.01PLUMBING WASTE & VENT PLANNP-2.0 KEY NOTES26 CENTER THE FS2 (FLOOR SINK) ON THE CENTER OF THE 3 COMPARTMENT SINK. INSTALLINDIVIDUAL DRAIN LINES FROM EACH STRAINER (3) TO INDIRECT WASTE TO THE FS2.SECURE THESE PIPES & PAINT THEM SILVER. PIPE THE DRAINS IN A MANNER THAT THEYDO NOT SPLASH OUT OF FLOOR SINK AND PROVIDES PROPER AIR GAP. DO NOT INSTALLANY TYPE OF TRAP BETWEEN THE STRAINERS ON THE SINK AND THE DISCHARGE INTOTHE FLOOR SINK. SEE DETAIL.27 THERE ARE AREAS IN STORAGE ROOM RESERVED FOR THE ELECTRICAL CONDUITS. THEP.C. IS TO KEEP ALL PLUMBING OUT OF THIS AREA. COORDINATE ANY PIPING BEINGINSTALLED IN THIS AREA WITH THE ELECTRICAL CONTRACTOR.P-2.0 KEY NOTES17 INSTALL THE 1" CONDENSATE LINES ON THE WALLS OF THE COOLER/FREEZERS FROMEACH EVAPORATOR UNITS, DROP LINE DOWN ON WALL TO 12" A.F.F., THEN EXIT THRU THEWALL, & DISCHARGE (INDIRECT WASTE) TO THE FLOOR SINK. PROVIDE THE PROPER AIRGAP. COVER ALL CONDENSATE PIPE WITH ARMAFLEX INSULATION, SEAL ALL JOINTS.INSTALL PIPING ON 7/8" THICK EPOXY COATED UNISTRUT CHANNEL WITH INSULATEDUNISTRUT CLAMPS. SLOPE THE PIPING MINIMUM 1/4"/FT. SEAL ALL WALL PENETRATIONS.SEE DETAILS. THE CONDENSATE PIPE INSIDE OF THE COOLER/FREEZER SHALL BE TYPEM OR L COPPER PIPE.18 INSTALL THE 1" CONDENSATE LINES ON THE WALLS OF THE BEVERAGE COOLER AS HIGHAS POSSIBLE, DROP DOWN IN THE CORNER OF BEVERAGE COOLER TO 3'-0" A.F.F., &PENETRATE THE WALLS INTO THE BEER COOLER. RUN THE CONDENSATE PIPING IN THEBEER COOLER ON THE WALL OVER TO THE FLOOR SINK.19 INSTALL HEAT TRACE ON THE CONDENSATE PIPING IN THE FREEZER/BEER COOLER UNITAS FREEZE PROTECTION. INSTALL RAYCHEM 5XL-1-CR HEAT TRACE CABLE WITHACCESSORIES AND AT-180 TAPE TO SECURE H.T. TO PIPING. PROVIDE A LOOP OF H.T.SECURED TO THE INLET NIPPLE OF THE EVAPORATOR PAN. ELECTRICAL CONTRACTORSHALL MAKE ALL THE ELECTRICAL CONNECTIONS AND MEET ALL CODE REQUIREMENTS.20 PROVIDE A 1" MINIMUM DEEP P-TRAP ON THE CONDENSATE LINE ON THE DISCHARGE OFTHE CONDENSATE PIPING FROM FREEZER/COOLER UNITS.21 THE P.C. SHALL PIPE THE DRAIN FROM THE T & P VALVE AND WATER HEATER PAN TO THEMOP SINK AS SEPARATE DRAINS LINES. SECURE THESE LINES.22 INSTALL MOP SINK FLUSH WITH FLOOR & NEXT TO EXPOSED STUD WALLS, WITH THESHEETROCK TO DROP DOWN ONTO THE LIP OF SINK.23 INSTALL 1 1/2" INDIRECT WASTE FROM P-8 (BAR SINK) TO THE FLOOR SINK BELOW EACHOF THESE SINKS. PREVENT SPLASHING.24 P.C. SHALL ROUTE DRAIN LINES FROM ICE BINS ALONG TOP OF BEVERAGE DISPENSERS,DROP DOWN INSIDE OF CABINET SPACE, PENETRATE THROUGH THE COUNTERTOP &INDIRECT WASTE THE DRAIN LINES TO A FLOOR SINK. SEE DETAIL. SEAL ALL HOLESTHROUGH OR IN COUNTER TOPS.25 INSTALL VENT AT THE CONDIMENT & PASTRY ISLAND'S FOR VENTING OF THE FLOORSINKS & FUTURE BAR SINKS. MUST MEET ALL CODE REQUIREMENTS.P-2.0 KEY NOTES11 THE GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL THE RAIN GUTTERS. THE P.C.SHALL INSTALL THE CANOPY DRAINS IN THE RAIN GUTTERS OR CANOPIES AS SHOWN ONTHE DRAWINGS. THE P.C. SHALL SEAL AROUND ALL DRAINS AND DROP THE CANOPYDRAIN LEADERS DOWN IN THE WALL. THE P.C. SHALL FIELD VERIFY EACH CANOPY DRAINLOCATION ON THE FRONT, SIDES, OR BACK OF THE BUILDING, AS SHOWN ON THEDRAWINGS. THE P.C. SHALL BE RESPONSIBLE TO CONNECT EACH CANOPY DRAIN ANDRESPECTIVE DROPS DOWN IN THE WALLS, OUT TO THE STORM SEWER. THE ELECTRICALCONTRACTOR IS TO INSTALL HEAT TRACE IN EACH GUTTER.12 THE P.C. SHALL BRING A (3” OR 4”) ROOF DRAIN LINE TO CONNECT TO THE CANOPY DRAINLINE DROPS IN THE WALL. RUN THESE LINES 5’-0” AWAY FROM THE BUILDING FOR THESITE CONTRACTOR TO CONNECT ONTO. THESE PIPES SHALL BE A MININUM OF 2’-6”BELOW GRADE. SEAL THE ENDS PIPES TO KEEP DEBRIS OUT. THE E.C. IS TO INSTALLHEAT TRACE IN EACH CANOPY DRAIN LINES, FROM THE GUTTER AREA OUT OR CANOPYTO THE STORM SEWER LOCATION. SEE THE ARCHITECTURAL DRAWINGS AND DETAILS.13 PROVIDE A 2" PIPE SLEEVE (OVERHEAD) FOR THE CO2 LINE PASS THRU FROM CO2 TANK(OUTSIDE) TO THE BAG IN THE BOX (INSIDE) IN KITCHEN AREA. USE LONG SWEEP 90DEGREE ELLS ONLY. MOUNT PIPE AT 60" OFF FINISHED FLOOR. CONFIRM THE EXACTPENETRATION LOCATION WITH TANK SUPPLIER. SEAL THIS PIPE WITH A CAP ALL, DRILL AHOLE THE SIZE OF THE CO2 PIPE IN THE CENTER OF CAP, INSTALL CAP ON SLEEVE ANDCAULK AROUND THE CO2 PIPE.14 INSTALL BEVERAGE (4" PVC) CONDUITS BELOW THE FINISHED FLOOR AND RISE UP TO 7"A.F.F. INSTALL B.C. DEEP ENOUGH TO MISS ALL PLUMBING, ELECTRICAL AND KITCHENEQUIPMENT LINES. USE ONLY LONG SWEEP 90° ELBOWS (36" RADIUS MINIMUM). SLOPEB.C. AT 1/8"/FT. TOWARDS BACK OF THE BUILDING. THE P.C. SHALL COORDINATE WITHTHE G.C. & ARCHITECTURAL ON THE INSTALLATION & LOCATIONS, THE BOX & S.S. CAP.SEE DETAIL.15 INSTALL A 4" PVC PIPE (SLEEVE) FOR THE WATER & FILTERED LINES BEING RUN OUT TOTHE CONDIMENT, PASTRY & COFFEE ISLANDS. THE P.C. SHALL COORDINATE WITH THEG.C. ON THE INSTALLATION & LOCATIONS.16 P.C. IS RESPONSIBLE TO PATCH ALL PENETRATIONS THRU THE WALLS & ROOF AND SEALTHEM WEATHER-TIGHT.P-2.0 KEY NOTES1 THE 4" BUILDING SEWER LINE SHALL CONNECT TO THE CITY SEWER LINE. THE P.C. SHALLPROVIDE AND INSTALL PIPING OF THIS LINE TO THE CONNECTION POINT PROVIDED BYTHE SITE CONTRACTOR (5'-0" PAST THE GREASE INTERCEPTOR).2 INSTALL GREASE INTERCEPTOR 10'-0" AWAY FROM THE BUILDING. PROVIDE AND INSTALLSEALED LIDS (2), RISE FROM TANK TO LIDS (2), AND VENTING OF THE TANK AND SYSTEM.THIS SYSTEM MUST BE TRAFFIC RATED. THE P.C. IS RESPONSIBLE FOR THE PIPING(GREASE AND SANITARY WASTE) OUT TO 5'-0" PAST THE GREASE INTERCEPTOR. SEEDETAILS.3 INSTALL A C.O.T.G. ON THE BUILDING GREASE, ROOF DRAIN AND SEWER LINES AS SHOWNON THE DRAWINGS. RISE EACH C.O.T.G. LEVEL WITH FINISH GRADE. INSTALL A NICKELBRONZE CLEANOUT (J.R. SMITH 4220) ON EACH RISER. POUR A 16" X 16" x 4" CONCRETEPAD AROUND EACH CLEANOUT, UNLESS THE CLEANOUT IS LOCATED IN A SIDEWALK ORDRIVEWAY.4 THE GREASE INTERCEPTOR VENTS (2" & 3") SHALL BE CONNECTED TO THE BUILDINGVENTING SYSTEM & DISCHARGE THRU A VTR.5 THE P.C. IS TO CONNECT ONTO THE NEW DOMESTIC WATER SERVICE LINE AT 5' 0"OUTSIDE OF THE HOUSEKEEPING PAD, LINE BROUGHT TO THIS LOCATION BY THE SITECONTRACTOR, FIELD VERIFY IT EXACT LOCATION. SEE SHEET P-2.1 FOR CONTINUATIONOF THIS WATER LINE TO THE PRV STATION INSIDE OF BUILDING.6 2 1/2" BUILDING COLD WATER SERVICE LINE & PRV STATION. PROVIDE ARMAFLEXINSULATION AND ENCASE THIS PIPE FROM 6" A.F.F. TO 18" PAST THE HOUSEKEEPING PAD.PIPE SLEEVE SHALL BE 4" OR LARGER PVC PIPE. SEE DETAIL.7 SEE SHEET P-2.1 FOR CONTINUATION OF THE DOMESTIC WATER PIPING TO THEPLUMBING FIXTURES IN THE BUILDING. PROTECT THE WATER SERVICE FROM ANYFREEZING CONDITIONS.8 SEE PLUMBING ROOF DRAIN PLAN (SHEET P-3.2) FOR THE SIZE AND LOCATION OF THEROOF DRAINS. THE ROOF DRAIN LEADER SHALL DROP DOWN INSIDE OF THE BUILDING,THRU THE BUILDING SLAB, AND OUT TO THE STORM SEWER OR BUILDING RETENTIONPOND. SEE THE CIVIL DRAWINGS FOR THE S.S. SEWER OR RETENTION PONDINFORMATION.9 SEE SHEET P-3.2 (PLUMBING ROOF DRAIN PLAN) FOR THE LOCATION OF OVERFLOWDRAINS AND PIPING. DAYLIGHT THE OVERFLOW DRAIN AS HIGH POSSIBLE THRUEXTERIOR WALL OR PARAPET. INSTALL A J.R. SMITH 1770 DOWNSPOUTS WITH RINGS,MOUNT FLUSH WITH THE WALL AND SECURE RING. SEAL ALL PENETRATIONS THRU THEWALLS.10 SEE SHEET P-3.2 FOR THE CONTINUATION OF THE PIPING AND SIZE OF THE OVERFLOWDRAINS ON THE ROOF. 9C9CP851P85120A17AFS2P919FS2FS1P7P12P1043AP3P4P1P1P2FD1FD1FD1FS1FD1HB1234789101112131416171819201 1/2" HW1 1/4" HW1" HW1 1/4" HW1" HW1/2" HW1/2"CW3/4"CW3/4" HW1/2" HW3/4" HW1 1/4"CW1 1/4"CW2"CW3/4"CW2"CWRETAIL10130° BEER COOLER11435° BEVERAGE COOLER115KITCHEN SERVICE113COFFEE PREP111STORAGE110WOMEN'S106MEN'S105OFFICE102EXIT HALLWAY104-10° FREEZER11935° STOR. COOLER11831/2"CW441414141/2" HW1/2" CWIN 4" PVC1/2" HW1/2" CWIN 4" PVC1733WHAWHAWHAWHA19P22"CW2"CW2"CW1 1/4"CW2"CW199672.172.1P851FS1FS11414211FD11"CW3/4"CW3/4" HW1 1/4"CW1/2"CW1/2" HW1/2"CW1 1/2"CW1 1/2" HW1 1/2"CW1 1/4" HW1 1/4" HW1/2"CW1456113821(2)184FS1P851P13P141/2" HW3/4"CW1/2" HW1/2"CW41 1/2"CW1/2"CW1 1/4" HW18171 1/2" HW1/2" HW4203/4"CW3/4" HW2"CWP171"CW2"CW2"CW2"CW2"CWFD21 1/4"CWA34BCDE1HB2HB1153/4"CW341419P53/4"CWHB21519P23/4"CW1 1/4"CW1 1/2"CWWHA1 1/4"CW1/2"CW1 1/4"CWP5FS1110FD11/2" HW1 1/4"CW1 1/4"CWWHA3/4"CW19WHA1/2" HW3/4"CW1 1/4"CW1/2" HW1/2" HW1/2" HW16162"CWFS1P23/4"CW95HB1223/4"CW3/4"CW231"CWGENERAL WATER NOTESALL WATER LINES SHALL BE HUNG USING COATED CLEVIS HANGERS, ALL THREAD ROD & SIDE BEAM ATTACHMENTS OR EPOXY COATED UNISTRUT CHANNEL, ALL THREAD ROD & SIDE BEAM ATTACHMENTS, SECURE PIPE WITH INSULATED CLAMPS.1ALL WATER PIPING, HOT AND COLD DOMESTIC LINES SHALL BE INSULATED. SEE INSULATION SCHEDULE ON SHEET P-1.0 FOR THE THICKNESS AND TYPE OF INSULATION.2ALL KITCHEN EQUIPMENT, OWNER PROVIDED EQUIPMENT, AND BAR SINKS INDIRECT WASTE DRAINS SHALL BE PIPED TO THE FLOOR SINK W/PROPER AIR GAP. PROVIDE CLEAN OUT ACCESS TO THESE FLOOR DRAINS WHICH LOCATED UNDER CABINETS.3EACH FLOOR DRAIN & FLOOR SINK SHALL BE PROVIDED WITH A TRAP PRIMER OR TRAP SEAL DEVICE. TRAP PRIMER: INSTALL 1/2" SOFT "K" COPPER OR ENGLE'S METHOD PEX PIPE, ENCASED IN PLASTIC PIPE SLEEVE, TO EACH OF THE FLOOR SINKS & FLOOR DRAINS. TRAP SEAL DEVICES: NO PIPING REQUIRED. PROSET TRAP GUARDS OR J. R. SMITH 2692 TRAP SEALS. SEE DETAIL.4INSTALL WATER BALLVALVE SHUTOFF STOPS TO ALL OWNER PROVIDED KITCHEN EQUIPMENT. THESE VALVES SHALL TO BE LOCATED AS PER MANUFACTURES RECOMMENDATIONS. PROVIDE & INSTALL ALL BACKFLOW PROTECTION NECESSARY AS REQUIRED BY LOCAL OR PLUMBING CODES.5SEE SHEET P-3.0, PLUMBING FIXTURE SCHEDULE FOR A LISTING OF ALL THE PLUMBING FIXTURES AND EACH FIXTURE'S TRIM.67ALL THE WATER VALVES ABOVE THE HARD LID OR THE DROP IN CEILING SHALL BE INSTALLED BETWEEN 1'-0" TO 1'-6" ABOVE THE CEILING. MAINTENENCE PERSONAL NEED TO ACCESS THESE VALVES USING A LADDER AND CANNOT REACH THEM IF THEY ARE INSTALLED UP CLOSE TO THE TRUSSES. PROVIDE BIG ENOUGH ACCESS DOOR TO ACCESS EACH VALVE AT EACH LOCATION. 9ANY & ALL PENETRATIONS THROUGH THE BUILDING ROOF OR WALLS SHALL BE SEALED WITH "DECK-MATE" FLASHING FOR ROOF & WALL SYSTEMD. G.C. SHALL PROVIDE, INSTALL & PAINT TO MATCH BUILDING. SUBCONTRACTOR SHALL COORDINATE WITH THE G.C. ALL PENETRATIONS AND SIZES. THE ARCHITECT SHALL HAVE THE FINAL INPUT ON HOW ALL PENETRATIONS SHALL BE SEALED. THE P.C. AND THE G.C. SHALL VERIFY WITH THE ARCHITECT WHAT SHALL BE REQUIRED OF THEM.8THE P.C. SHALL PROVIDE A LAMINATED VALVE TAG (BEFORE THE STORE HAS A FINAL WALK THRU) TO BE PERMANENTLY SECURED TO EACH OF THE COLD & HOT WATER VALVES WHICH WILL SERVE THE MAVERIKS EQUIPMENT, WHICH NEED COLD OR HOT WATER.THE P.C. SHALL MEET ALL LOCAL, STATE, AND HEALTH DEPARTMENT CODES AS THEY RELATE TO BACKFLOW PROTECTION. EACH PIECE OF EQUIPMENT THAT IS PROVIDED BY THE P.C. AND HE OWNER SHALL HAVE THE PROPER BACKFLOW PROTECTION. FIELD VERIFY WITH STATE, CITY & HEALTH DEPARTMENT WHAT IS REQUIRED FOR THE PROTECTION OF THIS STORE AND THE EQUIPMENT BEING INSTALLED. THE P.C. SHALL BE RESPONSIBLE TO PROVIDE THE NECESSARY DEVICES TO PROTECT EACH PIECE OF EQUIPMENT. PROVIDE FULL SIZE DRAINS TO AN APPROVED RECEPTACLE WITH THE PROPER AIR GAP.10DISHWASHER - ON HOT & COLD WATER LINES (WATTS # 288AC), ASSE 1001. WATTS # 26A 0-25 PSI VALVE 3/4" LIQUID FILLED GAUGE 0-100 PS1.3 COMPARTMENT SINK - FAUCETS W/ VACUUM BREAKERS WITH NO HOSE CONNECTION.ALL BACKFLOW ASSEMBLIES MUST MEET CURRENT COLORADO STATE PLUMBING CODE REQUIREMENTS. VENTED DOUBLE CHECK VALVES ARE NOT APPROVED.PROVIDE AND INSTALL WATTS SS009 STAINLESS STEEL REDUCED PRESSURE BACKFLOW PREVENTERS AT RO SYSTEM AND CARBONATOR. PLUMBER PROVIDED & INSTALLED BACKFLOW PROTECTION & PRESSURE REDUCINGRINSE SANITIZE3 COMP. SINKWASHFROM BOOSTERPUMP TOFIXTURES48"FLOORACCESSPANEL& DOORPRESSUREGAGE0-120 PSI,LIQUIDFILLEDMAIN SHUT-OFF VALVE2"2"2"P7- MOP SINK 1"TO ISLAND FAUCETS EODNEAROLOCIGNELAOISSEFDERETSIGER NORP R27241A.NIEL SONGORDON PROJECT NUMBER:185 S. State Street | Salt Lake City, Utah 84111SHEET NUMBERSHEET NAMEDRAWN BY: APPROVED BY:DRAWING ISSUEPROTOTYPE VERSION:THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC.DESCRIPTIONARCHITECT:ENGINEER:STAMP:ISSUANCEDATEConsulting EngineersThis document and the ideas and designs incorporated herein, as an instrument of professional service, is the property of NIELSON ENGINEERING, INC. and is not to be used, in whole or in part,for any other project without the written authorization of an authorized representative of NIELSON ENGINEERING, INC. Unauthorized use will be prosecuted to the fullest extent of the Law.Copyright c 2021 by: NIELSON ENGINEERING, INC.Nielson Engineering, Inc.OWNERSHIP OF DOCUMENTS156 North Twelfth AvenuePocatello, Idaho 83201PHONE (208) 232-2577FAX (208) 234-09184/30/2021 1:55:15 PMPLUMBING COLD &HOT WATER PLAN19335PERMIT SET 4/30/21BH ApproverP-2.1MAVERIK, INC.I-25 & E. COUNTY ROAD 32FT COLLINS, COMAVERIK C-STORE1/4" = 1'-0"P-2.11PLUMBING COLD & HOT WATER PLANNP-2.1 KEY NOTES17 INSTALL 4" PVC PIPE UNDER THE BUILDING SLAB AS A PIPE CHASE TO SUPPLY WATER TOTHE CONDIMENT & PASTRY ISLANDS. INSTALL 1/2" CW, & 1/2" HW FROM THE SOURCE(DROPPED FROM THE CEILING SPACE) TO ISLAND AS SHOWN. THIS PIPING SHALL BEWISBRO PEX PIPE WITH BRASS FITTING-COPPER X PEX ADAPTERS, IF IT MEETS CODEREQUIREMENTS. PROVIDE VALVES ON EACH OF THE LINES, AT THE DROP DOWN SOURCEAND IN THE CABINET SPACE OF THE CONDIMENT & PASTRY ISLAND. EACH LINE SHALLHAVE A PERMANENT TAG, LISTING TYPE OF WATER THIS LINE PROVIDES. THE P.C. SHALLCOORDINATE WITH THE G.C. & ARCHITECTURAL ON THE INSTALLATION & LOCATIONS.SEE DETAIL.18 INDIRECT WASTE BAR SINKS (P-8) WITH 1 1/2" WASTE LINE. INSTALL HOT AND COLDWATER STOPS, ESCUTCHEONS, AND S. S. BRAIDED SUPPLIES TO EACH OF THE SINKS.19 INSTALL WATER HAMMER ARRESTERS AS SHOWN ON THIS SHEET. SIZE EACH ARRESTERBASED ON THE FIXTURE LOAD AND AS TO THE MANUFACTURE'S RECOMMENDATIONS.LOAD EACH WHA WITH THE WATER FIXTURES UNITS BEING SERVICED BY THIS WATERHAMMER ARRESTOR.20 THERE ARE AREAS IN STORAGE ROOM RESERVED FOR THE ELECTRICAL CONDUITS. THEP.C. IS TO KEEP ALL PLUMBING OUT OF THIS AREA. COORDINATE ANY PIPING BEINGINSTALLED IN THIS AREA WITH THE ELECTRICAL CONTRACTOR.21 THE P.C. SHALL STUB OUT 3/4" HOT & COLD WATER LINES W/ FULLPORT BALLVALVES &CAP @ 48" A.F.F.22 THE P.C. SHALL INSTALL A FULLPORT SHUTOFF VALVE FOR THE WATER LINE TO THEHOSE BIBS. THE VALVE SHALL BE CLEARLY LABELED, AND ACCESSIBLE BY AN ACCESSPANEL ABOVE THE PRV STATION, OR IN THE CEILING.23 PROVIDE A 1" WATER SUPPLY LINE FOR THE FUEL CANOPY. PROVIDE AND INSTALL A AVBFOR THIS LINE IN THE BUILDING. SLEEVE THE PIPE IN A 3" OR LARGER PVC PIPE SLEEVEWITH LONG SWEEP 90'S.P-2.1 KEY NOTES1 THE P.C. SHALL CONNECT ONTO DOMESTIC WATER SERVICE AT 5'-0" BEYOND THEBUILDING, WATER LINE BROUGHT TO THIS LOCATION BE THE SITE CONTRACTOR. FIELDVERIFY THE EXACT LOCATION AND DEPTH OF PIPE.2 PROVIDE A 1" WATER SUPPLY LINE FOR LAWN IRRIGATION. SOME CITIES REQUIRE ASEPARATE WATER METER FOR IRRIGATION, FIELD VERIFY. PROVIDE ALL THE NECESSARYSHUTOFF VALVES, DRAIN VALVES, VALVE BOXES, BACKFLOW PROTECTION & PIPING TOPROVIDE THE IRRIGATION CONTRACTOR A CONNECT POINT. MEET ALL STATE AND LOCALCODE REQUIREMENTS.3 INSTALL OUTSIDE WALL HYDRANTS W/LOCKABLE DOORS, AT 36" ABOVE FINISHED FLOOROR SIDEWALK. SEE DETAIL. TURN KEYS OVER TO OWNER.4 INSURE THAT ALL WATER PIPING IN THE OUTSIDE WALLS ARE PROTECTED AGAINSTPOSSIBILITY OF FREEZING. KEEP PIPING ON THE WARM SIDE OF THE INSULATION ANDCLOSE TO THE BACK OF THE SHEETROCK. IN AREAS WHERE THIS IS NOT POSSIBLE, THEP.C. IS RESPONSIBLE TO INSTALL HEAT TRACE ON THESE LINES. IN THE COLUMN WALLWHERE THE FRONT OUTSIDE WALL HYDRANT AND PIPING IS INSTALLED, THE P.C. SHALLPROVIDE HEAT TRACE ON THE HYDRANT AND PIPING. INSTALL THE HEAT TRACE FROMTHE DRAIN TUBING OF THE HYDRANT TO JUST OUTSIDE OF THE OUTSIDE WALL BY THESHUTOFF VALVE IN THE CEILING.5 INSTALL PRESSURE REDUCING STATION (PRV) AT THIS LOCATION. SEE DETAIL FORPIPING OF THE PRV STATION.6 THE P.C. SHALL PROVIDE THE REDUCED PRESSURE BACKFLOW PREVENTER. THIS VALVEMAY BE INSTALLED BY THE METER OR IN THE BUILDING. IF INSTALLED IN THE BUILDINGTHE P.C. SHALL INSTALL OR IF OUTDOORS THE SITE CONTRACTOR SHALL INSTALL IT.(THE LOCATION OF THIS VALVE WILL BE DICTATED BY THE LOCAL CODES IN THE AREA.)7 PROVIDE AND INSTALL ACCESS DOOR. LOCATE THE ACCESS DOOR AT 48" ABOVEFINISHED FLOOR TO TOP OF THE DOOR AND CENTERED IN THE WALL SPACE. THE MAINSHUTOFF VALVE & PRESSURE GAUGE WILL BE INSTALLED IN THIS SPACE.8 INSTALL THE MOP SINK FAUCETS AT 3'-0" AND THE CHEMICAL FAUCETS AT 4'-3" ABOVETHE FINISHED FLOOR. PROVIDE 3/4" SPRING LOADED CHECK VALVES IN BOTH HOT &COLD LINES WHICH DROP DOWN TO THE MOP SINK FAUCET AND CHEMICAL FAUCETS.SEE DETAIL.9 THE P.C. SHALL INSTALL THE OWNER PROVIDED CHEMICAL FEED UNIT. FIELD VERIFYWITH LOCAL HEALTH DEPT. THE TYPE AND LOCATION ON ANY BACKFLOW REQUIREMENTSFOR THIS CHEMICAL FEED UNIT. LOCATE THE UNIT ABOVE THE CHEMICAL FAUCETS ATTHE MOP SINK, FIELD VERIFY WITH OWNER EXACT HEIGHT. THE P.C. IS RESPONSIBLE TOINSTALL, TEST, AND PROVIDE BACKFLOW10 PROVIDE AND INSTALL FULLPORT BALLVALVES ON BOTH HOT AND COLD LINES TO THEWATER HEATER. INSTALL THE WATER HEATER ON 14" WATER HEATER STAND, ANALUMINUM WATER HEATER PAN UNDER THE TANK, AND NEXT TO THE MOP SINK. PIPETHE DRAINS FROM T&P VALVES AND THE WATER HEATER PAN SEPARATELY TO INDIRECTWASTE TO THE MOP SINK. PROVIDE SEISMIC RESTRAINTS BOTH TOP & BOTTOM OF THEWATER HEATER. PROVIDE FACTORY START-UP. SEE DETAIL. SET DISCHARGETEMPERATURE FROM THE HOT WATER HEATER AT 140°F.11 INSTALL THERMAL EXPANSION TANK ON WATER HEATER, BETWEEN COLD WATER INLETSHUTOFF VALVE & COLD WATER INLET NIPPLE TO THE WATER HEATER. SECURE THISTANK. SEE DETAIL.12 SEE SHEETS P-2.2 (FW) FOR THE LISTING OF THE FILTERED WATER. SEE ITEM P10 THE"RO" FILTER WATER SYSTEM FURNISHED BY THE OWNER AND INSTALLED BY THEPLUMBING CONTRACTOR.13 INSTALL 3/4" ISOLATION SHUTOFF VALVES WITH 3/4" WATTS #601S INLINE CHECK VALVES(IN THE CEILING SPACE) ON THE HOT AND COLD WATER SUPPLY LINES TO THE 3COMPARTMENT SINK.14 INSTALL ISOLATION SHUTOFF BALLVALVES IN CEILING SPACE AS SHOWN, IF IN A HARDCEILING, PROVIDE PAINTABLE ACCESS DOORS OR ABOVE THE DROP IN CEILING PROVIDEVISIBLE VALVE SIGNS AT EACH LOCATION. PROVIDE THE OWNER WITH A COMPLETELAMINATED VALVE CHART OF THE WHOLE BUILDING'S VALVES AT THE FINAL INSPECTION.15 MOUNT WALL HYDRANTS W/LOCKABLE DOORS IN EACH RESTROOM AT 18" A.F.F. TO TOPOF THE BOX.16 DROP 3/4" HOT AND COLD WATER LINES IN WALL SPACE TO 36" A.F.F. STUB OUT OF WALLAND BUILD MANIFOLD WITH 1/2" BRANCHES. INSTALL 1/2" BALLVALVES ON EACH BRANCH.RUN PEX PIPE FROM THESE VALVES INTO THE PIPE CHASE AND OUT TO THE ISLANDS.INSTALL A SHUTOFF VALVE AT ISLANDS ON EACH LINE. SEE DETAIL. 519C9C515120A19P1043A332345678910111/2" FWIN 4" PVC1/2" FWIN 4" PVC17A37771781781747RETAIL10130° BEER COOLER11435° BEVERAGE COOLER115COFFEE PREP111STORAGE110MEN'S105EXIT HALLWAY104-10° FREEZER11935° STOR. COOLER118KITCHEN SERVICE113WOMEN'S106OFFICE1029672.172.1P85147113821(2)1843/4"FW1/2"FW3/4"FW1/2"FW1/2"FW1/2"FW3/4"FW1/2"FW3/4"FW3/4"FW1/2"FW3/4"FW3/4"FW3/4"FW1/2"FW3/4"FW1/2"FW3/4"FW1/2"FW3/4"FW737AA2345BCDE1110P8P8P8P9P7P12P2P1P5P5P1P2P3P2P4P2363/4"FW3779512133/4"FW3/4"FW1/2"FW9C9C9CP10OWNER PROVIDE "RO" FILTER SYSTEM/PLUMBING CONTRACTOR INSTALLEDPIPE, FITTINGS, AND VALVES TO BE USED TO INSTALL THE OWNER FURNISHED"RO" FILTER WATER SYSTEM (NO SUBSTITUTES ALLOWED).PIPE: WIRSBO "AQUAPEX" WHITE TUBING, ENGEL METHOD PEX OR PEX-a TUBING.FITTINGS: WIRSBO "EP" FITTINGS, ProPEX STAINLESS STEEL MALE THREADEDADAPTER (Q8525050) WITH ProPEX SLIP RING (W/EXPANDER TOOL).SHUTOFF VALVES: PARKER HANNIFIN "TRUESEAL" BALLVALVE MODEL PP6VME8-MG 1/2"NPTF THREAD X 3/8" OD TUBING, 1/2" STAINLESS STEEL COUPLING, AND ESCUTCHEON.NOTE: DO NOT USE ANY MALLEABLE METAL PIPE OR FITTING,BRASS OR BRASS FITTINGS, OR COPPER PIPE AND FITTINGS IN THE"RO" PIPING SYSTEM. ALL PIPE AND FITTING MUST BE APPROVEDFOR "RO" WATER.SUPPLIES: PIPING FROM PARKER HANNIFIN BALL SHUTOFF VALVE ON "RO" FILTERSYSTEM TO THE OWNER SUPPLIED EQUIPMENT (ICE MAKERS, COFFEE UNITS,CARBONATORS, & ETC.) SHALL BE PARKER-HANNIFIN "SERIES E" POLYETHYLENE"NATURAL" TUBING WITH PARKER-HANNIFIN "TrueSeal" FITTINGS.NOTE: PIPE, FITTINGS, AND TUBING FOR THE "RO" WATER SYSTEM3M 3MTANK SHUTOFF VALVE (COMES WITH TANK)LEGENDPROVIDED BY INSTALLERINSTALLATION KITBEV140/BEV160TO EQUIPMENTCHECK VALVE (PROVIDED BY INSTALLER)RO SAMPLE VALVE1/2" NPT FEEDWATER INLETINTAKE KIT SHUTOFF VALVE(SOLD SEPARATELY)PRE-FILTER SAMPLE VALVE3/8" TUBE OUT TO DRAINHF90-CL-RO (PRE-FILTER)HFRO 500 (RO MEMBRANE)1/2" OUTLET TO TANK40 GALLON PRESSURE TANK1 1/4" INLET, TANK 24.5"D X 55.5"H87 LBS. (SOLD SEPARATELY)(POST FILTER-SOLD SEPARATELY)BYPASS (PROVIDED BY INSTALLER)1/2" NPT OUTLET TO EQUIPMENTINTAKE KIT SHUTOFF VALVE(SOLD SEPARATELY)DISHWASHER - ON HOT & COLD WATER LINES (WATTS # 288AC), ASSE 1001. WATTS # 26A 0-25 PSI VALVE 3/4" LIQUID FILLED GAUGE 0-100 PS1.3 COMPARTMENT SINK - FAUCETS W/ VACUUM BREAKERS WITH NO HOSE CONNECTION.ALL BACKFLOW ASSEMBLIES MUST MEET CURRENT PLUMBING CODE REQUIREMENTS. VENTED DOUBLE CHECK VALVES ARE NOT APPROVED.PROVIDE AND INSTALL WATTS SS009 STAINLESS STEEL REDUCED PRESSURE BACKFLOW PREVENTERS AT RO SYSTEM AND CARBONATOR. PLUMBER PROVIDED & INSTALLED BACKFLOW PROTECTION & PRESSURE REDUCINGGENERAL FILTERED WATER NOTESALL FILTERED WATER LINES SHALL BE HUNG USING COATED CLEVIS HANGERS, ALL THREAD ROD & SIDE BEAM ATTACHMENTS OR EPOXY COATED UNISTRUT CHANNEL, ALL THREAD ROD & SIDE BEAM ATTACHMENTS, SECURE PIPE WITH INSULATED CLAMPS.1ALL WATER PIPING, DOMESTIC OR FILTERED LINES SHALL BE INSULATED. SEE INSULATION SCHEDULE ON SHEET P-1.0 FOR THE THICKNESS AND TYPE OF INSULATION.2SEE ISOMETRIC DRAWINGS ON SHEET P-3.2 FOR THE "RO" FILTER WATER PIPING.34ALL THE WATER VALVES ABOVE THE HARD LID OR THE DROP IN CEILING SHALL BE INSTALLED BETWEEN 1'-0" TO 1'-6" ABOVE THE CEILING. MAINTENENCE PERSONAL NEED TO ACCESS THESE VALVES USING A LADDER AND CANNOT REACH THEM IF THEY ARE INSTALLED UP CLOSE TO THE TRUSSES. PROVIDE BIG ENOUGH ACCESS DOOR TO ACCESS EACH VALVE AT EACH LOCATION. 5THE P.C. SHALL PROVIDE A LAMINATED VALVE TAG (BEFORE THE STORE HAS A FINAL WALK THRU) TO BE PERMANENTLY SECURED TO EACH OF THE COLD & HOT WATER VALVES WHICH WILL SERVE THE MAVERIKSEQUIPMENT, WHICH NEED COLD OR HOT WATER.THE P.C. SHALL MEET ALL LOCAL, STATE, AND HEALTH DEPARTMENT CODES AS THEY RELATE TO BACKFLOW PROTECTION. EACH PIECE OF EQUIPMENT THAT IS PROVIDED BY THE P.C. AND HE OWNER SHALL HAVE THE PROPER BACKFLOW PROTECTION. FIELD VERIFY WITH STATE, CITY & HEALTH DEPARTMENT WHAT IS REQUIRED FOR THE PROTECTION OF THIS STORE AND THE EQUIPMENT BEING INSTALLED. THE P.C. SHALL BE RESPONSIBLE TO PROVIDE THE NECESSARY DEVICES TO PROTECT EACH PIECE OF EQUIPMENT. PROVIDE FULL SIZE DRAINS TO AN APPROVED RECEPTACLE WITH THE PROPER AIR GAP.6EODNEAROLOCIGNELAOISSEFDERETSIGER NORP R27241A.NIEL SONGORDON PROJECT NUMBER:185 S. State Street | Salt Lake City, Utah 84111SHEET NUMBERSHEET NAMEDRAWN BY: APPROVED BY:DRAWING ISSUEPROTOTYPE VERSION:THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC.DESCRIPTIONARCHITECT:ENGINEER:STAMP:ISSUANCEDATEConsulting EngineersThis document and the ideas and designs incorporated herein, as an instrument of professional service, is the property of NIELSON ENGINEERING, INC. and is not to be used, in whole or in part,for any other project without the written authorization of an authorized representative of NIELSON ENGINEERING, INC. Unauthorized use will be prosecuted to the fullest extent of the Law.Copyright c 2021 by: NIELSON ENGINEERING, INC.Nielson Engineering, Inc.OWNERSHIP OF DOCUMENTS156 North Twelfth AvenuePocatello, Idaho 83201PHONE (208) 232-2577FAX (208) 234-09184/30/2021 1:55:31 PMPLUMBINGFILTERED WATERPLAN19335PERMIT SET 4/30/21BH ApproverP-2.2MAVERIK, INC.I-25 & E. COUNTY ROAD 32FT COLLINS, COMAVERIK C-STORE1/4" = 1'-0"P-2.21PLUMBING FILTERED WATER PLANNP-2.2 KEY NOTES1 INSTALL 4" PVC PIPE UNDER THE BUILDING SLAB AS A PIPE CHASE. THESE CHASES SHALLPROVIDE A SPACE TO RUN "RO" WATER LINES FROM A WALL LOCATION, UNDER THE SLAB,OVER TO EACH OF THE CONDIMENT AND PASTRY ISLANDS. THE P.C. SHALL INSTALL A 1/2"LINE FROM THE VALVE LOCATION NEAR A WALL, THRU THE PIPE CHASE, AND RISE UP INEACH OF THE ISLANDS. THE PIPING SHALL BE ENGEL'S METHOD TYPE WIRSBO"AQUAPEX" PIPE WITH EP OR STAINLESS STEEL FITTING OR ADAPTERS W/ProPEX SLIPRINGS. MEET ALL CODE REQUIREMENTS RELATED TO THIS "RO WATER TYPE OF PIPING".PROVIDE A SHUTOFF VALVES (PARKER HANNIFIN BALLVALVES W/ESCUTCHIONS), AT THEINLET LOCATION AND OUTLET LOCATIONS UNDERNEATH THE CABINET SPACE) ON EACHOF THE WATER LINES. EACH LINE SHALL HAVE A PERMANENT TAG (AT THE INLET ANDOUTLET LOCATIONS) WHICH LISTS "RO" WATER BEING SUPPLIED AT THESE LOCATIONS.THE P.C. SHALL COORDINATE WITH THE G.C. & ARCHITECTURAL ON THE INSTALLATION &LOCATIONS. SEE DETAIL.2 PROVIDE SHUTOFF VALVES (PARKER HANNIFIN BALLVALVES W/ESCUTCHEONS) AT 18"ABOVE FINISHED FLOOR OR AS DIRECTED BY THE OWNER, SEE THE KITCHEN EQUIPMENTSCHEDULE FOR EQUIPMENT WATER REQUIREMENTS. INSTALL ALL THE NECESSARYSTAINLESS STEEL BACKFLOW PROTECTION DEVICES WHICH ARE REQUIRED BY LOCALHEALTH DEPARTMENTS OR PLUMBING CODES. THE P.C. SHALL CONNECT THE "RO"FILTER WATER OR DOMESTIC WATER TO OWNER FURNISHED EQUIPMENT AS DIRECTED.3 PROVIDE "RO" FILTERED WATER TO THE OWNER PROVIDED EQUIPMENT ON THESECOUNTERTOPS. DROP DOWN IN THE WALL TO 18" OFF FINISHED FLOOR LEVEL BELOWTHE COUNTERTOPS. INSTALL PARKER HANNIFIN BALLVALVES W/ESCUTCHEONS. LABELEACH WATER LINE WITH A PERMANENT TAG.4 PROVIDE "RO" FILTERED WATER TO THE OWNER PROVIDED EQUIPMENT ON THESECOUNTERTOPS. DROP DOWN IN THE WALL TO 95" OFF FINISHED FLOOR LEVEL ABOVETHE COUNTERTOPS. PROVIDE ONE FILTERED WATER LINE W/SHUTOFF TO EACH ICEMACHINE. INSTALL PARKER HANNIFIN BALLVALVES W/ESCUTCHEONS. LABEL EACHWATER LINE WITH A PERMANENT TAG.5 THE P.C. SHALL INSTALL, MOUNT, AND CONNECT THE OWNER PROVIDED "RO" WATERFILTER SYSTEM. PROVIDE AND INSTALL ALL THE NECESSARY PARKER HANNIFINBALLVALVES, FITTINGS, AND PIPE REQUIRED TO INSTALL AND PROVIDE A FULLYFUNCTIONING "RO" WATER FILTER SYSTEM. P.C. SHALL PROVIDE THE START UP ON THISUNIT. THE P.C. SHALL MOUNT THIS UNIT ON A SHELF BEING PROVIDED BY THE GENERALCONTRACTOR. SEE THE DETAIL OF THIS UNIT THIS SHEET, (UNIT MOUNTED ON A SHELFABOVE THE PRV STATION).6 KE11 & KE9'S, LOCATED AT COFFEE WALL. PROVIDE INDIVIDUAL SHUTOFF VALVES ANDESCUTCHEONS (PARKER HANNIFIN BALLVALVES W/ESCUTCHEONS) UNDERNEATH THECABINET SPACE. THE P.C. SHALL PROVIDE (4-FW) INSIDE OF THE CABINET SPACE AT 18"A.F.F. PROVIDE PERMANENT LABELS ON EACH VALVE STATING THESE VALVES ARE "RO"FILTERED WATER. SEE DRAWINGS FOR LAYOUT.7 INSTALL PARKER HANNIFIN BALLVALVES W/ESCUCTEONS BEFORE CONNECTING TO THEOWNER PROVIDED KITCHEN EQUIPMENT. THESE VALVES SHALL TO BE LOCATED ASSHOWN ON THE DRAWINGS AND PER OWNER'S REQUEST, ABOVE OR BELOW THECOUNTERTOP. PROVIDE AND INSTALL ALL NECESSARY STAINLESS STEEL BACKFLOWPROTECTION DEVICES WHICH ARE REQUIRED BY THE LOCAL HEALTH DEPARTMENT ORPLUMBING CODES.8 DROP 3/4" FILTERED WATER LINE IN WALL SPACE TO 36" A.F.F. STUB OUT OF WALL ANDBUILD MANIFOLD WITH 1/2" BRANCHES. INSTALL 1/2" BALLVALVES ON EACH BRANCH. RUNPEX PIPE FROM THESE VALVES INTO THE PIPE CHASE AND OUT TO THE ISLANDS. INSTALLA SHUTOFF VALVE AT ISLANDS ON EACH LINE. SEE DETAIL.9 INSTALL ISOLATION SHUTOFF BALLVALVES IN CEILING SPACE AS SHOWN, IF IN A HARDCEILING, PROVIDE PAINTABLE ACCESS DOORS OR ABOVE THE DROP IN CEILING PROVIDEVISIBLE VALVE SIGNS AT EACH LOCATION. PROVIDE THE OWNER WITH A COMPLETELAMINATED VALVE CHART OF THE WHOLE BUILDING'S VALVES AT THE FINAL INSPECTION.10 THE P.C. SHALL INSTALL A 1/2" "RO" FILTERED WATER LINE TO THE NU-VU OVEN/PROOFER(FURNISHED AND INSTALLED BY THE OWNER). THE 1/4" NPT WATER CONNECTION IS ONTHE LEFT HAND SIDE OF THE OVEN/PROOFER AS YOU FACE THE UNIT. THE CONNECTIONIS ON THE BACK SIDE OF THE OVEN/PROOFER. THE CONNECTION HEIGHT IS 17 5/16" OFFTHE FINISHED FLOOR LEVEL. PROVIDE PARKER HANNIFIN BALLVALVE W/ESCUTCHEON AT20" OFF FINISHED FLOOR LEVEL, JUST TO THE LEFT OF THE OVEN/PROOFER. PIPE THEOVEN/PROOFER WITH A PARKER HANNIFIN POLYETHYLENE "NATURAL" "SERIES E" TUBINGFROM THE VALVE TO THE CONNECTION OF THE OVEN/PROOFER. THERE IS NO DRAIN ONTHIS UNIT, IT HAS A EVAPORATOR PAN IN THE BOTTOM OF THE UNIT. NO BACKFLOWPROTECTION IS NEEDED ON THIS UNIT.11 INSTALL (2) BALLVALVES W/ ESCUCTEONS BEFRORE CONNECTING FILTERED WATER TOEACH WATER BOOSTER. THESE VALVES SHALL BE LOCATED 48" A.F.F.. PROVIDE ANDINSTALL ALL NECESSARY STAINLESS STEEL BACKFLOW PROTECTION DEVICES WHICHARE REQUIRED BY THE LOCAL HEALTH DEPARTMENT & PLUMBING CODE.12 IF REQUIRED BY LOCAL JURISDICTION, THE P.C. SHALL MOUNT BACKFLOW PREVENTERSON INSIDE OF BOH WALL AND ROUTE THE WATER LINES THROUGH WALL CHASESSERVING BEVERAGE STATION EQUIPMENT.13 IF REQUIRED BY LOCAL JURISDICTION, THE P.C. SHALL MOUNT BACKFLOW PREVENTERSIN BOTTOM 18" OF CABINET WITH THE SHUTOFF VALVE. RT-1171 CFH1P1661P1661P1661P1661P1661P1661234533355P8P8P9P7P12P10100CFHGRT-2171 CFHRT-3148 CFHTOTAL:604 CFH51111P16611111112"G1"G1 1/4"G1 1/4"G1"G1"G1"GRETAIL10130° BEER COOLER11435° BEVERAGE COOLER115COFFEE PREP111STORAGE110MEN'S105EXIT HALLWAY104-10° FREEZER11935° STOR. COOLER118KITCHEN SERVICE113WOMEN'S106OFFICE102111P166P81P16611112"G1"GA2345BCDE111P1661P166P8P2P1P5P5P1P2P3P2P4P2PIPEPOWER CONNECTION. (JUNCTION BOX NOTINCLUDED) USE ONE PER CIRCUIT. ALLOWFOR A 2'-0" SERVICE LOOP.SPLICE KIT. USE ASNEEDED. ALLOW FOR A2'-0" SERVICE LOOP.TEE KIT. USE AT TEES INTRACING PIPING. ALLOW FORA 2'-0" SERVICE LOOP.RUN CABLE ON OUTSIDE(LONG) RADIUS OF ELBOWS(TYP.)DOMESTIC HOTWATER PIPINGEND SEAL. USE ONE PERCIRCUIT PLUS ONE PER TEE.NO SERVICE LOOP REQUIRED.GLASS TAPE. USE TAPE TOATTACH CABLE TO PIPE EVERY2'-0". ONE ROLL WILL HANDLEAPPROXIMATELY 50'-0".FIBERGLASSPIPEINSULATIONHEAT TRACECABLEPLACE HEAT TRACEBETWEEN "4 O'CLOCK& 8 O'CLOCK POSITIONSON PIPE.FIBERGLASS PIPEINSULATION."ELECTRIC TRACED" LABEL.PLACE AT 10'-0" INTERVALSON ALTERNATING SIDES OFINSULATION.48NOTE:THE P.C. SHALL FURNISH AND COORDINATE THE INSTALLATION OF THE HEAT TRACE SYSTEM. MUST MEET ALL REQUIREMENTS TO INSTALL THE CABLE ON THE PIPING. IF REQUIRED BY CODE, THE P.C. SHALL HIRE AN ELECTRICAL CONTRACTOR TO INSTALL THE CABLE ON PIPING.P16HEAT TRACING SCHEDULE11= START OF CIRCUITFLOW OF HEAT TRACE RUNP.C. TO FURNISH - MEET ALL CODE FOR INSTALLATION. TRACING CIRCUIT= END OF HEATGENERAL HT/GAS NOTESTHE GAS CONTRACTOR SHALL SUPPORT OR ANCHOR ALL THE GAS PIPING. THE CONTRACTOR SHALL USE MIRO GAS & MECHANICAL SUPPORTS OR MAKE ALL THE PIPING SOLID.1ALL WATER PIPING, DOMESTIC OR FILTER SHALL BE INSULATED. SEE INSULATION SCHEDULE ON SHEET P-1.0 FOR THE THICKNESS AND TYPE OF INSULATION.2THE GAS PIPING AND INSTALLATION SHALL CONFORM TO ALL LOCAL GAS CODES AND NFPA 58. THE GAS CONTRACTOR SHALL PROVIDE ALL THE TESTING OF THIS SYSTEM AS REQUIRED BY THE A.H.J. WHO IS INSPECTING THE SYSTEM.3ALL EXPOSED GAS PIPING AND FITTINGS SHALL BE PAINTED. THE PIPING ON THE OUTSIDE BACK OF THE BUILDING SHALL BE PAINTED TO MATCH THE WALL OR THE GAS METER. PAINT THE GAS PIPE AND FITTINGS ON THE ROOF YELLOW. THE GAS CONTRACTOR SHALL PAINT THE PIPE AND FITTINGS WITH ONE COAT OF PRIMER AND ONE COAT OF PAINT. THIS PAINTING SHALL BE DONE IN A PROFESSIONAL MANNER, COVER THE WHOLE PIPE AND FITTINGS (TOP & BOTTOM), AND KEEP THE PAINT OFF THE SURROUNDING WALLS, FIXTURES, EQUIPMENT, FLOORS, WALLS, & ETC.4HANG GAS LINE USING CLEVIS HANGERS, ALL THREAD ROD, SIDE BEAM ATTACHMENTS OR EPOXY COATED INISTRUT CHANNEL, ALL THREAD ROD, SIDE BEAM ATTACHMENTS AND SECURE PIPE WITH UNISTRUT CLAMPS.5UNITLOADGAS LOAD SUMMARYGAS LOAD SUMMARYTOTAL171 CFH604 CFH130 ft.TOTAL DEVELOPED LENGTH6"-11" WATER COLUMN REQUIRED DOWNSTREAM OF METERROOFTOP UNIT RT-1114 CFHWATER HEATER171 CFHROOFTOP UNIT RT-2148 CFHROOFTOP UNIT RT-3MULTIPLIER: 879EODNEAROLOCIGNELAOISSEFDERETSIGER NORP R27241A.NIEL SONGORDON PROJECT NUMBER:185 S. State Street | Salt Lake City, Utah 84111SHEET NUMBERSHEET NAMEDRAWN BY: APPROVED BY:DRAWING ISSUEPROTOTYPE VERSION:THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC.DESCRIPTIONARCHITECT:ENGINEER:STAMP:ISSUANCEDATEConsulting EngineersThis document and the ideas and designs incorporated herein, as an instrument of professional service, is the property of NIELSON ENGINEERING, INC. and is not to be used, in whole or in part,for any other project without the written authorization of an authorized representative of NIELSON ENGINEERING, INC. Unauthorized use will be prosecuted to the fullest extent of the Law.Copyright c 2021 by: NIELSON ENGINEERING, INC.Nielson Engineering, Inc.OWNERSHIP OF DOCUMENTS156 North Twelfth AvenuePocatello, Idaho 83201PHONE (208) 232-2577FAX (208) 234-09184/30/2021 1:55:47 PMPLUMBING HEATTRACE & GAS PLAN19335PERMIT SET 4/30/21BH ApproverP-2.3MAVERIK, INC.I-25 & E. COUNTY ROAD 32FT COLLINS, COMAVERIK C-STORE1/4" = 1'-0"P-2.31PLUMBING HEAT TRACE & GAS PLANSCALE: NONEP-2.3HEAT TRACE SYSTEM DETAIL2NP-2.3 KEY NOTES1 AS UTILITY COMPANY. THE LOCAL GAS UTILITY COMPANY SHALL PROVIDE & INSTALL THEGAS SERVICE LINE (6 TO 11) INCHES OF WATER COLUMN), THE GAS METER, AND THEMETER POST. PROVIDE AND INSTALL A A FULL PORT SHUT OFF VALVE UPSTREAM OF THEGAS METER, AND ANY PROTECTION NECESSARY FOR THE GAS METER AS REQUIRED BYTHE A.H.J. IF NECESSARY INSTALL 4" STEEL PIPE BOLLARDS, FILLED WITH CEMENT, ASPROTECTION FOR THE GAS METER. THE TOTAL GAS LOAD TO THE BUILDING IS 604 CFH.2 THE GAS CONTRACTOR SHALL CONNECT TO THE OUTLET SIDE OF THE GAS METER, THENRUN THE GAS LINE INTO THE BUILDING, AND RUN GAS DISTRIBUTION PIPING EACH GASAPPLIANCE IN THE BUILDING.3 CONNECT THE GAS PIPING TO EACH GAS APPLIANCES, PROVIDE AND INSTALL A GASSHUTOFF VALVE, UNION AND MINIMUM OF A 6" DIRT LEG. ALL UNIONS SHALL BEACCESSIBLE.4 INSTALL THE WATER HEATER ON 14" WATER HEATER STAND, AN ALUMINUM WATERHEATER PAN UNDER THE TANK, AND NEXT TO THE MOP SINK. PIPE THE DRAINS FROM T&PVALVES AND THE WATER HEATER PAN SEPARATELY TO INDIRECT WASTE TO THE MOPSINK. PROVIDE SEISMIC RESTRAINTS BOTH TOP & BOTTOM OF THE WATER HEATER.PROVIDE FACTORY START-UP. SEE DETAIL. SET DISCHARGE TEMPERATURE FROM THEHOT WATER HEATER AT 140°F.5 SEAL ALL PENETRATIONS THRU THE WALLS OR ROOF WEATHER-TIGHT AND PAINT ALLEXPOSED GAS PIPING. PROVIDE AN ESCUTCHEON ON THE PIPING AS IT GOES THRU THEWALL. THE GAS CONTRACTOR SHALL PROVIDE ANY NECESSARY PROTECTION FOR THEGAS METER AS REQUIRED BY CODE. IF CODE REQUIRES THE GAS CONTRACTOR SHALLINSTALL TWO 4" SCHEDULE 40 BLACK PIPE BOLLARDS. SET THE BOLLARDS IN CONCRETEMINIMUM OF 3'-0" DEEP AND MINIMUM OF 3'-0" ABOVE THE FINISHED GRADE. PAINT THESEBOLLARDS TO MATCH THE BUILDING.6 INSTALL HEAT TRACE CABLE (RAYCHEM HWAT-R2, 208 VOLTS, 125°F TEMP. 175 FEET W/ 15AMP. BREAKER) ON ALL DOMESTIC HOT WATER LINES. PROVIDE AND INSTALL (1)HWAT-ECO CONTROLLER, TEMPERATURE MAINTENANCE. THE STARTING LOCATION OFTHE HEAT TRACE IS AT THE HOT WATER OUTLET NIPPLE ON THE WATER HEATER. THETERMINATING OF THE HEAT TRACE BRANCHES ARE OUT TO THE HOT WATER PIPEFARTHEST BRANCH. THERE ARE 12 FINAL (TERMINATIONS) ENDS IN THIS SYSTEM. THEPLUMBING CONTRACTOR IS TO PROVIDE ALL THE HEAT TRACE CABLE, ALL THEMATERIALS, AND ALL THE ACCESSORIES FOR A COMPLETE AND FULLY FUNCTIONAL HEATTRACE SYSTEM. HE IS TO INSTALL THIS SYSTEM IF LOCAL CODE PERMITS, ON ALL HOTWATER PIPING, AS SHOWN ON THIS SHEET. IF REQUIRED BY THE LOCAL CODES, THAT ANELECTRICAL CONTRACTOR SHALL INSTALL ALL ELECTRICAL CABLES, THEN THEELECTRICAL CONTRACTOR SHALL BE HIRED BY THE PLUMBING CONTRACTOR TO INSTALLTHIS SYSTEM WITH ALL THE CABLES, THE CONNECTIONS, AND PERFORM ALL THE TESTINGOF THE SYSTEM AS PER THE MANUFACTURER'S RECOMMENDATIONS 12343344RT-1171 CFHGPR # 1RT-2171 CFHGPR # 2RT-3148 CFHGPR # 3G2 PSI2 PSI2 PSI2 PSI2 PSI2 PSI3/4"G3/4"G3/4"G3/4"G3/4"G3/4"GTOTAL:604 CFH114 CFHGPR # 4343/4" HW30° BEER COOLER11435° BEVERAGE COOLER115COFFEE PREP111STORAGE110MEN'S105-10° FREEZER11935° STOR. COOLER118KITCHEN SERVICE113WOMEN'S106OFFICE102RETAIL1011 1/2" HW1 1/4" HW1 1/2" HW1 1/4" HW1 1/2" HW1 1/4" HW1 1/2" HW1 1/4" HW1 1/2" HW1 1/2" HW1 1/4" HW1 1/4" HW3/4" HW3/4" HW3/4" HW3/4" HW3/4" HW3/4"GA234BCDE1P8P8P8P9P7P12P10P1P5P2P8P5P1P2P3P2P2P41" HW1"G3/4"GROOF12"NATURAL GAS REGULATORGOVENOR 2 PSI IN / 6" TO 11" W.C. OUTFISHER FIGURE 50-2PRESSURE GAUGE0-35 INCHES W.C.VENT TOATMOSPHERESIMILAR TO VTRTURNED DOWNW/ FISHER Y602BUG SCREENINCREASE OR DECREASE AS REQUIRED TOSIZE INDICATEDON DRAWINGS18" MIN. AT SAMEDIAMETER ASREGULATOROUTLETNOTE:REGULATOR PRESSUREADJUSTMENT SHOULD BEMADE WITH ALL DOWNSTREAM EQUIPMENT INFULL OPERATION2 PSI NAT. GASGAS COCKFISHER FIGURE 50-2PRESSURE GAUGE0-21 PSIDIRT LEG1. DOMESTIC WATER:PEX PIPING MAY BE INSTALLED IN ALL CONCEALED SPACES, ABOVE CEILING, AND INBETWEEN WALLS IF APPROVED BY THE LOCAL PLUMBING CODE.THE P.C. SHALL USE THE FOLLOWING:PEX PIPE: UPONOR- PEX-a (ENGLE-METHOD CROSSLINKED POLYETHYLENE). ASTM 876/877.FITTINGS: UPONOR- PROPEX ENGINEERED POLYMER (EP) FITTINGS. ASTM 1960 ANDANSI/NSF 14 & ANSI/NSF 61.CONNECTORS: UPONOR- PROPEX RINGS (ENGLE-METHOD CROSSLONKED POLYETHYLENE).ANSI/NSF 14 & ANSI/NSF 61.SUPPORTS: UPONOR- PEX-a PIPE SUPPORT (CHANNEL). GALVANIZED STEEL CHANNEL. FORASTME 84 INSTALLATIONS. ALL PIPE MUST BE COVERED WITH A PEX-aPIPE SUPPORT OR A MINIMUM 1/2" THICK RATED INSULATION. REFER TOUPONOR INSTALLATION INSTRUCTIONS."ALL EXPOSED PIPING SHALL BE TYPE "L" COPPER WITH WROUGHT FITTINGS."(NO SUBSTITUTIONS) : WRONG MATERIALS WILL BE REMOVED AND REPLACED AT THE PLUMBING CONTRTACTOR'S EXPENSE.PEX PIPE ALTERNATE SPECIFICATIONSP19SYMBOLWDESCRIPTIONVCW HWPLUMBING FIXTURE SCHEDULE ALTERNATEEQUIPMENT AND INSTALLATION BY PLUMBING CONTRACTOR-HOT WATER RECIRC. PUMP- B & G MODEL B & G NBF-12U/LW, 3/4" UNION, 2,800 RPM, 55WATTS, .48 F.L. AMPS, 115 V / PHASE 1, 9.3 LBS, ALL BRONZE PUMP W/ CONTROL,HONEYWELL L6006C1018 AQUASTAT. MOUNT PUMP MINIMUM OF 6'-0" A.F.F.3/4"--GENERAL GAS/WATER NOTESTHE GAS CONTRACTOR SHALL SUPPORT OR ANCHOR ALL THE GAS PIPING. THE CONTRACTOR SHALL USE MIRO GAS & MECHANICAL SUPPORTS OR MAKE ALL THE PIPING SOLID.12THE GAS PIPING AND INSTALLATION SHALL CONFORM TO ALL LOCAL GAS CODES AND NFPA 58. THE GAS CONTRACTOR SHALL PROVIDE ALL THE TESTING OF THIS SYSTEM AS REQUIRED BY THE A.H.J. WHO IS INSPECTING THE SYSTEM.3ALL EXPOSED GAS PIPING AND FITTINGS SHALL BE PAINTED. THE PIPING ON THE OUTSIDE BACK OF THE BUILDING SHALL BE PAINTED TO MATCH THE WALL OR THE GAS METER. PAINT THE GAS PIPE AND FITTINGS ON THE ROOF YELLOW. THE GAS CONTRACTOR SHALL PAINT THE PIPE AND FITTINGS WITH ONE COAT OF PRIMER AND ONE COAT OF PAINT. THIS PAINTING SHALL BE DONE IN A PROFESSIONAL MANNER, COVER THE WHOLE PIPE AND FITTINGS (TOP & BOTTOM), AND KEEP THE PAINT OFF THE SURROUNDING WALLS, FIXTURES, EQUIPMENT, FLOORS, WALLS, & ETC.HANG GAS LINE USING CLEVIS HANGERS, ALL THREAD ROD, SIDE BEAM ATTACHMENTS OR EPOXY COATED INISTRUT CHANNEL, ALL THREAD ROD, SIDE BEAM ATTACHMENTS AND SECURE PIPE WITH UNISTRUT CLAMPS.4ALL WATER LINES SHALL BE HUNG USING COATED CLEVIS HANGERS, ALL THREAD ROD & SIDE BEAM ATTACHMENTS OR EPOXY COATED UNISTRUT CHANNEL, ALL THREAD ROD & SIDE BEAM ATTACHMENTS, SECURE PIPE WITH INSULATED CLAMPS6ALL WATER PIPING, HOT AND COLD DOMESTIC LINES SHALL BE INSULATED. SEE INSULATION SCHEDULE ON SHEET P-1.0 FOR THE THICKNESS AND TYPE OF INSULATION.5OUTSIDE ATMOSPHERE. PROTECT AGAINST MOISTURE ENTERING THE VALVE BY PROVIDING THE PROPERNOTE: ALL GAS REGULATORS WILL NOT BE CONCEALED, MUST BE ACCESSIBLE AND VENTED TO THEPROVIDE A 6" DIRT LEG, A GAS VALVE AND A UNION AT EACH REGULATOR, THEY MUST BE ACCESSIBLE.MUST MEET NFGC & NFPA 54, CHAPTER 2.9 OVERPRESSURE PROTECTION. GOVERNOR 1-888-618-8787.TURN DOWNS AND PROPER HEIGHT ABOVE THE ROOF LINE. USE GOVERNOR GAS PRESSURE REGULATORS.ALL GAS PIPE OVER 2" MUST BE WELDED.GAS REGULATORS5-8.52 PSI GAS MAIN PRESSURELOADGASREG. #MAINPIPEOUTLETCFHLOADGOVERNORW.C.BUILDING GAS APPLIANCESTOTAL BUILDING DEVELOPED LENGTH: 130 FEET (ADDED 25%), MULTIPLIER: 879 TOTAL BUILDING"150,000 BTURTU #1GPR #1300523/4""""171 CFH150,000 BTURTU #2GPR #230052 342 CFH130,000 BTURTU #3GPR #330052 490 CFH100,000 BTUWATER HEATER (P12)GPR #430052 604 CFH3/4"3/4"3/4"3/4""LOCAL GAS UTILITY: EXCEL ENERGY PHONE #: 1-800-895-4999604 CFHFULL PORT BALL VALVEGAS PRESSURE REGULATORCHECK VALVEUNIONLEGENDCIRCULATING PUMPDRAINTEMPERATURE & PRESSURERELIEF VALVEGAS VALVENOTES:T&P RELIEF VALVE SETSAME AS HEAT INPUTRATING OR 150 PSIAS PER ENERGY CODE INSTALLHEAT NIPPLES ON HOT & COLD SUPPLIESMOP SINKPIPE T&P, WATER HEATER PAN,AND CONDENSATE DRAIN RUN SEPARTATELY TO MOP SINKCEILINGFINISHEDFLOOR1 1/2"3/4"140°F HOTWATERRETURNHOT WATERTO FIXTURESUNISTRUTPROVIDE & INSTALL SEISMICBRACING TO WALL (TYP.)SUCH AS MANUFACTURED BYSPACEMAKER (712) 542-4699WATER HEATER PAN & DRAIN14" WATER HEATER STANDCOLDWATERSUPPLYPVCINTAKE & EXHAUSTGAS LINE2 PSIREGULATORWALLSTORM KING "HYDROCLAW" BRACKET.EODNEAROLOCIGNELAOISSEFDERETSIGER NORP R27241A.NIEL SONGORDON PROJECT NUMBER:185 S. State Street | Salt Lake City, Utah 84111SHEET NUMBERSHEET NAMEDRAWN BY: APPROVED BY:DRAWING ISSUEPROTOTYPE VERSION:THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC.DESCRIPTIONARCHITECT:ENGINEER:STAMP:ISSUANCEDATEConsulting EngineersThis document and the ideas and designs incorporated herein, as an instrument of professional service, is the property of NIELSON ENGINEERING, INC. and is not to be used, in whole or in part,for any other project without the written authorization of an authorized representative of NIELSON ENGINEERING, INC. Unauthorized use will be prosecuted to the fullest extent of the Law.Copyright c 2021 by: NIELSON ENGINEERING, INC.Nielson Engineering, Inc.OWNERSHIP OF DOCUMENTS156 North Twelfth AvenuePocatello, Idaho 83201PHONE (208) 232-2577FAX (208) 234-09184/30/2021 1:57:32 PMPLUMBING 2 PSIGAS, HW RECIRC.& PEX ALT.19335PERMIT SET 4/30/21Author ApproverP-2.3AMAVERIK, INC.I-25 & E. COUNTY ROAD 32FT COLLINS, COMAVERIK C-STORE1/4" = 1'-0"P-2.3A1PLUMBING 2 PSI GAS, HW RECIRC. PLAN & PEXPIPING ALTERNATESCALE: NONEP-2.3AGAS PRESSURE REGULATOR DETAIL2NNOTE: GAS CONTRACTOR IS TO VERIFY WITH CONSTRUCTION MANAGER AND GAS COMPANY WHAT GAS PRESSURE IS BEING SUPPLIED TO THE BUILDING BEFORE ANY GAS PIPING IS TO BE INSTALLED.P-2.3A KEY NOTES1 NEW GAS SERVICE TO BUILDING BY LOCAL GAS UTILITY COMPANY. THE LOCAL GASUTILITY COMPANY SHALL PROVIDE & INSTALL 2 PSI GAS SERVICE LINE, THE GAS METER,AND THE METER POST. PROVIDE AND INSTALL ANY PROTECTION NECESSARY FOR THEGAS METER AS REQUIRED BY THE A.H.J. IF NECESSARY INSTALL 4" STEEL PIPE BOLLARDS,FILLED WITH CEMENT, AS PROTECTION FOR THE GAS METER. THE TOTAL GAS LOAD TOTHE BUILDING IS 604 CFH.2 THE GAS CONTRACTOR SHALL CONNECT TO THE OUTLET SIDE OF THE GAS METER, THENRUN THE GAS LINE INTO THE BUILDING, AND RUN GAS DISTRIBUTION PIPING EACH GASAPPLIANCE IN THE BUILDING.3 CONNECT THE GAS PIPING TO EACH GAS APPLIANCES, PROVIDE AND INSTALL A GASSHUTOFF VALVE, GAS PRESSURE REGULATOR & UNION AND MINIMUM OF A 6" DIRT LEG.ALL UNIONS SHALL BE ACCESSIBLE.4 SEAL ALL PENETRATIONS THRU THE WALLS OR ROOF WEATHER-TIGHT AND PAINT ALLEXPOSED GAS PIPING. PROVIDE AN ESCUTCHEON ON THE PIPING AS IT GOES THRU THEWALL. THE GAS CONTRACTOR SHALL PROVIDE ANY NECESSARY PROTECTION FOR THEGAS METER AS REQUIRED BY CODE. IF CODE REQUIRES THE GAS CONTRACTOR SHALLINSTALL TWO 4" SCHEDULE 40 BLACK PIPE BOLLARDS. SET THE BOLLARDS IN CONCRETEMINIMUM OF 3'-0" DEEP AND MINIMUM OF 3'-0" ABOVE THE FINISHED GRADE. PAINT THESEBOLLARDS TO MATCH THE BUILDING.SCALE: NONEP-2.3AWATER HEATER RECIRC. DETAIL3 8"6"4"4"2" - 3"3/4" - 1-1/2"PVCWATER LINEENCASEMENT SIZINGPVC ENCASEMENTSEAL WITH FOAM SEALANTBALL SHUT-OFF VALVESLOPE TOWARD OUTSIDE OF BUILDINGCONCRETE FLOOR5' MIN.4"TO WATERPRESSUREREGULATORSTATIONFOOTING ANDFOUNDATIONWALLDOMESTIC WATERLINE TYPE K COPPERNO JOINTS UNDER FLOOR.FS11/2"FW1TOP VIEWKITCHEN SERVICEREAR VIEWWALLICESODA MACHINEOUTLETDELI PREPDRINKYOGURTSLUSHAS POSSIBLECOUNTER. HOLD1" HOLE INCLOSE TO UNITDRAIN LINE ASLINE, MINIMUMDRAIN3/4"COLD WATER SUPPLYTYPICAL FIXTUREFIXTURE DRAININSULATED PIPINGSHUT-OFF VALVETRAP PRIMER FITTINGFINISHED FLOORALL PIPE WALL PENETRATIONSSHALL HAVE ESCUTCHEONS MAKE CONNECTION TO DRAINTRAP PRIMER CONNECTION1/2" (SOFT "K" COPPERNO JOINTS UNDER FLOOR,INSULATE W/ 1/2" ARMAFLEX1. PROVIDE TRUE-BRO INSULATION KITS, ON ALL DRAINS AND STOPS ON ALL SINKS WITH EXPOSED DRAINS OR SHUTOFF VALVES.3. MINIMUM SIZE FOR CONDENSATE LINES IS 3/4", SEE PIPE SCHEDULE FOR MATERIALS.4. INDIRECT WASTE TO SINKS, MAY BE PVC-DWV IF CODE PERMITS AND THE WATER TEMPERATURE TO SINKS IS NO OVER 120° F.IF OVER 120 ° F, USE HARD DRAWN L COPPER PIPE WITH FITTINGS.5. FLOOR DRAINS ARE TO BE SET FLUSH WITH THE FINISHED FLOOR.6. CABINETS WITH FLOOR SINK IN THEM SHALL BE OPEN TO THE FLOOR SINK FOR CLEANING AND ACCESS.7. MAINTAIN SEPARATION BETWEEN SANITARY WASTES AND FOOD SERVICES WASTES.8. ALL VENT LINES IN EXTERIOR WALLS WILL BE HELD ON THE WARM SIDE OF BUILDING INSULATION.9. ALL UNDER FLOOR WATER PIPING WILL BE WRAPPED IN MINIMUM OF 1/2" THICK ARMAFLEX INSULATION, UNLESS PIPING ISIN A PIPE CHASE.10. SEE ROOF SHEET FOR THE EXACT LOCATION OF EXISTING ROOF DRAINS AND VENT RISERS.11. DO NOT INSTALL ANY WATER PIPING IN EXTERIOR WALLS, ENSURE ALL WATER PIPING IS KEEP IN THE WARM ATTIC SPACEOR INSIDE OF BUILDING WALL ON THE INTERIOR OF THE VAPOR BARRIER.12. SET OUTLET TEMPERATURE ON WATER HEATERS TO BE 140°F. HAND SINKS SHALL HAVE 110°F WATER SUPPLIED TO THEM.13. HEAT TRACE FOR GUTTERS, OVERFLOW DRAINS, & ROOF DRAINS BY ELECTRICAL CONTRACTOR.14. INSTALL GAS PIPING TO MEET ALL CODES AND NFPA REQUIREMENTS, PROVIDE PERMITS, MATERIALS, & LABOR FOR AFUNCTIONAL PIPING SYSTEM, PERFORM ALL TESTING TO MEET THESE CODES.15. CONFIRM THE EXACT LOCATION OF ALL EQUIPMENT PRIOR TO MAKING PLUMBING ROUGH-IN.16. ANY PENETRATIONS THRU FIRE RATED PARTITIONS SHALL BE SEALED WITH SCOTCH-3M #FS 195 WRAP AND CP# 25 CAULK.17. THE PLUMBING CONTRACTOR SHALL NOT INSTALL PIPING ABOVE OR WITHIN THE CODE REQUIRED WORKING CLEARANCES OFANY ELECTRICAL PANELS, SWITCH GEAR, OR CONDUITS, COORDINATE ALL WORK WITH THE ELECTRICAL CONTRACTOR.18. THE PLUMBING CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS TO OWNER SUPPLIED EQUIPMENT REQUIRING A PLUMBINGCONNECTIONS.19. ANY UNDER FLOOR PIPING WILL NOT BE ROUTED UNDERNEATH FREEZERS UNITS.20. INSULATE ALL WATER PIPING, ROOF DRAIN PIPING, OVERFLOW DRAIN PIPING, & FREZZERS/COOLERS CONDENSATE LINES.21. CLEANOUTS WILL BE INSTALLED AS PER CODE REQUIREMENTS.22. VENTS OFFSETTING HORIZONTALLY MUST BE AT LEAST 6" ABOVE THE FLOOR RIM OF THE HIGHEST FIXTURE.23. THE PLUMBING CONTRACTOR SHALL PROVIDE AND INSTALL ALL PLUMBING FIXTURES AND EQUIPMENT SHOWN ON THE DRAWINGSLISTED AS 'P' ITEMS. OWNER FURNISHED ITEMS SHALL BE CONNECTED TO THE BUILDING DRAINS AND WATER BY THE P.C..24. ONLY FULL PORT BALLVALVES SHALL BE PERMITTED TO BE USED FOR ZONE OR AREA VALVES IN THE BUILDING.25. INSTALL WATER HAMMER ARRESTORS TO PREVENT WATER HAMMER IN BUILDING, INSTALL AS SHOWN ON THE DRAWINGS.26. ALL HOT WATER, COLD WATER, ROOF DRAIN, OVERFLOW DRAIN, AND CONDENSATE PIPING WILL BE INSULATED WITH A MINIMUMOF 1" THICK INSULATION, SEE INSULATION SCHEDULE ON THESE DRAWINGS FOR THE EXACT SIZE.2. SEE THE KITCHEN EQUIPMENT SHEETS FOR REQUIREMENTS AND HEIGHTS. EQUIPMENT IS OWNER FURNISHED, VENDOR INSTALLED, WITH THE P. C. TO MAKE HOOKUPS TO WATER LINES AND DRAIN LINES, PROVIDING ALL MATERIALS AND LABOR.GENERAL NOTESWATER PRESSURE FRICTION LOSS CALCULATIONSNO PRV REQUIRED:WATER PRESSURE: HIGH LOWWATER UTILITY COMPANYWATER METER SIZEIF MAXIMUM WATER PRESSURE IS OVER 60 PSI THEN A PRESSURE REGULATING VALVE IS REQUIREDBUILDING ADDRESSFORT COLLINS LOVELAND WATER DISTRICTMAVERIK I25 & E COUNTY RD 32, FORT COLLINS, CO.2 "55 PSI N/A1-970-434-7328NOTE : THESE FIGURES ARE BASED ON A BEST GUESS FROM THE CITY.PIPE SIZING SCHEDULE (BASED ON FLUSH TANKS)MAX. FIXT. UNITSVELOCITY (FPS)MAX. FIXT. UNITSVELOCITY (FPS)PSI/100 FTFLOW (GPM)PIPE SIZEFLOW (GPM)PIPE SIZEPSI/100 FT1-1/2"1-1/2"3/4"3/4"1/2"2.55.801/2"2.73.603.91"11.71-1/4"1"04.61-1/4" 2-1/2"2-1/2"2"2"3" 4"3" 4"14.571720.332.205.1135.866.6956.93463 2452.7 3.9 4.6 5.1 5.8 6.92.55.8 11.720.332.2 66.6DEVELOPED LENGTHTOTAL AVAILABLE PRESSUREPRESSURE LOSS THRU METERAVAILABLE WATER PRESSUREAVAILABLE FRICTION LOSS PER 100 FT.PRESSURE REQUIRED AT MOST REMOTE FIXTUREPRESSURE LOSS THRU BACKFLOW PREVENTERPRESSURE LOSS THRU PRESSURE REGULATOR VALVEPRESSURE LOSS DUE TO ELEVATION ( FT. X 0.43)DOMESTIC WATER FIXTURE UNITS: (FU) = GPMSIZE: PRESSURE:MAKE: MODEL NO.:(IRRIGATION WILL BE CONDUCTED DURING OFF-PEAK HOURS) 100 FT. X --X 1.4 =170'238.0188.5 PSI BOOST PRESSURE-= PSI3.6(FLUSH VALVE)238.0112.0(25.0)(12.0)-8.5(4.6)(7.8)7249.5(0)8.6= PSI(BOOSTER PUMP)58.0(4.6)(7.8)(0)(25.0)(12.0)8.6117.83367.92607.9117.8PIPE SIZING SCHEDULE (BASED ON FLUSH VALVES)= PSI= PSI= PSI= PSI= PSI= PSI PSI PSI PSI PSI PSI PSI PSIP3P1P2P4SYMBOLWDESCRIPTIONVCW HWPLUMBING FIXTURE SCHEDULEEQUIPMENT AND INSTALLATION BY PLUMBING CONTRACTOR2"_4"_2"4"3/4"2"3"1"1"3/4"2"3"P5P6__WATER CLOSET (ADA)- KOHLER K-96057-0 "HIGHCLIFF", 12" ROUGH, ELONGATED BOWL,16 7/8" BOWL HEIGHT, 1 1/2" SPUD, 1.6 GPF, SIPHON JET OPERATING SYSTEM, WHITEWATER CLOSET. PROVIDE AND INSTALL KOHLER K-4670-C WHITE SEAT W/OPEN FRONTAND SLOAN MODEL 8111-1.6/1.1 "SOLIS" 1.6 OR 1.1 GPF, SOLAR POWERED DUAL FLUSHFLUSHOMETER.WATER CLOSET- KOHLER K-96053-0 "WELLCOMME" ULTRA, 12" ROUGH, 15 1/4" BOWL HEIGHT,1 1/2" SPUD, 1.6 GPF, VITREOUS CHINA, ELONGATED BOWL, SIPHON JET OPERATINGSYSTEM, WHITE WATER CLOSET. PROVIDE AND INSTALL KOHLER K-4670-C WHITE SEATW/OPEN FRONT AND SLOAN MODEL 8111-1.6/1.1 "SOLIS" 1.6 OR 1.1 GPF, SOLARPOWERED DUAL FLUSH FLUSHOMETER.URINAL (ADA) - KOHLER "BARDON" MODEL K-4991 ET-0, WHITE, WALL HUNG, VITREOUS CHINA, 3/4" TO SPUD, "WATERSENSE COMPLIANT", 1.0 GPF, HIGH EFFICIENCY URINAL. PROVIDE & INSTALL SLOAN MODEL 8186-1 "SOLIS" 1.0 GPF SOLAR POWERED FLUSHOMETER AND A J.R. SMITH 0636 "OFF THE FLOOR" URINAL SUPPORT. MOUNT URINAL 17" FROM FINISHED FLOOR TO LIP OF URINAL.URINAL - KOHLER "BARDON" MODEL K-4991 ET-0, WHITE, WALL HUNG, VITREOUS CHINA, 3/4" TO SPUD, "WATERSENSE COMPLIANT", 1.0 GPF, HIGH EFFICIENCY URINAL. PROVIDE & INSTALL SLOAN MODEL 8186-1 "SOLIS" 1.0 GPF SOLAR POWERED FLUSHOMETER AND A J.R. SMITH 0636 "OFF THE FLOOR" URINAL SUPPORT. MOUNT URINAL 24" FROM FINISHEDFLOOR TO LIP OF URINAL.P12P14P13P15P16P10P9P73"2"3/4"2 1/2"2" / 3"4"____1 1/4"1 1/4"1/2"1/2"1/2"MOP SINK- FIAT-TSB 3000 TERRAZZO MOP SINK, 24" X 24" X 12" WITH 6" DROPDROP FRONT, S.S PERFORATED 3" STRAINER, 830-AA SINK FAUCET WITH VACUUMBREAKER, S. S. THRESHOLD, 832-AA HOSE & BRACKET, QUICK DRAIN CONNECTOR,889-CC MOP BRACKET, & MSG 2424 S.S. HEAVY GAUGE WALL GUARDS. PROVIDESHUT OFF VALVES IN THE CEILING ABOVE THIS SINK. MOUNT SINK FAUCET 36" A.F.F..2-WOODFORD #24 FAUCETS W/ METAL HANDLES, 4'3" ABOVE SINK. 2-WATTS 601S C.V..WATER FILTER- OWNER FURNISHED, P.C. TO INSTALL UNIT. P.C. TO FURNISH WATERLINES TO UNIT WITH SHUT OFF VALVE AND RUN FILTER WATER (FW1) TO FIXTURESOR KITCHEN EQUIPMENT SHOWN ON THE DRAWINGS.OUTSIDE GREASE INTERCEPTOR- PRE-BUILD OR POURED IN PLACE 1,500 GALLONGREASE INTERCEPTOR. P. C. TO PROVIDE THE INSTALLATION OF THIS ITEM, SEE SHEETP-3.1, DETAIL 12, FOR DIMENSIONS OF TANK, WITH INLETS & OUTLETS AND THE SIZINGOF TANK.1/2"IWHEAT TRACE- RAYCHEM HWAT-PLUS HEATING CABLE. CIRCUIT #1--HWAT-R2, (RED)W/ HWAT-ECO CONTROLLER, SET AT 125 DEGREES, 15 AMPS, TOTAL APPROX. LENGTH175 FEET, 208 VOLTS W/ ALL NECESSARY ACCESSORIES. P.C. IS TO PROVIDE ANDINSTALL A COMPLETE HEAT TRACE SYSTEM W/ ALL ACCESSORIES, AS SHOWN ON THEDRAWINGS. IF LOCAL CODES REQUIRES AN ELECTRICAL CONTRACTOR TO INSTALL THEHEAT TRACE, THEN THE P.C. SHALL HIRE AND SUPERVISE THIS INSTALLATION, THE P.C.SHALL DETERMINE THE PIPING (DOMESTIC HOT WATER) THAT REQUIRES A HEAT TRACESYSTEM. SEE SHEET P-2.3, DETAIL 2.1 1/2"2 1/2"P8IW1/2" 1/2" 1 1/2"BAR SINK - THE SINKS TO BE FURNISHED AND INSTALLED BY THE MILL WORK CONTRACTOR. THE P.C. SHALL TRIM THESE SINKS OUT AND CONNECT THEM TO THE WATER AND SEWER SYSTEMS. PROVIDE AND INSTALL CHICAGO 527-GN8AE35ABCP TWO HANDLE BAR FAUCET, KOHLER K 8807-3 1/2" SINK STRAINER, SYMMONS MODEL 7-210-CK THERMOSTATIC MIXING VALVE (SET THE OUTLET HOT WATER TEMPERATURE AT 105 TO 110 DEGREES), BRASSCRAFT KTCR19X C STOPS, ESCUTCHEONS, STAINLESSSTEEL BRAIDED SUPPLIES, AND 1 1/2" INDORECT WASTE TO FLOOR SINK. POSITION FAUCET AS SHOWNON THE DRAWINGS._____________P113 COMPARTMENT SINK – OWNER PROVIDED, P.C. TO INSTALL SINK. FIELD VERIFY EXACT LOCATION WITH GENERAL CONTRACTOR. PROVIDE AND INSTALL (1) CHICAGO MODEL 540-LDLESAB FAUCET BODY WITH CHICAGO GN2BVBE2-2JKCP SPOUT. PROVIDE AND INSTALL (1) CHICAGO MODEL 510-G613L12XKAB SPRAYER AND FAUCET. SINK BASKET STRAINERS BY OWNER. DRAINS TO BE INDIRECT WASTED SEPARATELY INTO THE FLOOR SINK WHICH IS CONNECTED TO GREASE INERCEPTOR. PROVIDE SHUT OFF VALVES AND CHECK VALVES ABOVE THE CEILING TO ISOLATE THE WATER TO THIS SINK.WATER HEATER- A. O. SMITH CYCLONE XI BTX-100 (NATURAL GAS), 50 GALLON TANK,100,000BTU/HR INPUT, 128 GALLON PER HOUR @ 90°F RISE, POWER DIRECT VENTED SEALEDCOMBUSTION (VERTICALLY OR SIDEWALL VENTING), AND 96% EFFICIENT. PROVIDE ANDINSTALL AMTROL ST-12 THERMAL EXPANSION TANK, INSTALLED ON THE COLD INLET TOTANK BETWEEN THE SHUT OFF VALVE AND THE INLET NIPPLE TO THE TANK. SET THEWATER HEATER ON 14" STAND WITH A WATER HEATER PAN. PROVIDE SEISMIC WALLBRACKETS BOTH TOP AND BOTTOM OF TANK. PIPE T & P VALVE & WATER HEATERPAN TO THE MOP SINK WITH AN AIR GAP. PROVIDE A 3" OR 4" SCHEDULE 40 PVCFLUE & COMBUSTION AIR PIPING THRU THE ROOF, SEAL WEATHER-TIGHT, AN PROVIDEFLUE CAPS. SEE SHEET P-3.1, DETAIL 12. THE WATER HEATER REQUIRES 120 VOLTPOWER. SET THE OUTLET TEMPERATURE TO 120°F. THE HEIGHT IS 68 1/2" X 22"DIAMETER, SHIPPING WEIGHT 255 POUNDS.LAVATORY (ADA) - ELKAY "LUSTERTONE" LLVR1916-1, STAINLESS STEEL SINGLE BOWL 19 5/8" X 16 11/16", SINGLE FAUCET HOLE, FULLY UNDERCOATED, LKF293 OVERFLOW ASSEMBLY, SELF-RIMMING, OVAL LAVATORY. PROVIDE & INSTALL ELKAY LK174 BRASS GRID STRAINER W/OVERFLOW OPENING, TOTO SELF-GENERATING "ECOPOWER" SENSOR THERMAL MIXING FAUCET-MODEL TEL101-D10ET WITH STANDARD SPOUT WITH THERMOSTATIC MIXING VALVE (SET AT 110°F TO 115°F HOT WATER), BRASSCRAFT KTCR19X C STOPS, ESCUTCHEONS, AND TRUE-BRO 102W ADA INSULATION KIT. MOUNT LAVATORY IN THE VANITY COUNTERTOP BY OWNER.FD1FS2FS1_ _1 1/2" 3"__3"_ _1 1/2"2"FLOOR DRAIN- J.R. SMITH NO. 2005Y03-A06-P050-NB CAST IRON F.D. WITH 6" DIA.NICKEL BRONZE STRAINER. PROVIDE TRAP PRIMERS ON ALL FLOOR DRAINS AS PER CODE.PROVIDE J. R. SMITH 2699A1-CP AS SHOWN ON THE DRAWINGS. IF APPROVED BYAUTHORITY HAVING JURISDICTION, THE P.C. MAY USE PROSET TRAP GUARDSIN LIEU OF TRAP PRIMERS. SEE SHEET P-3.1, DETAIL 6.FLOOR SINK- J.R. SMITH MODEL #3140Y02-PDBS, 12 1/2" X 12 1/2" X 6", "2" OUTLET.AND POLISHED ALUMINUM DOME STRAINER. USE DEEP SEAL P-TRAPS ON FLOOR SINKSW/TRAP PRIMERS. IF APPROVED BY AUTHORITY HAVING JURISDICTION, THE P.C. MAY USEPROSET TRAP GUARDS IN LIEU OF TRAP PRIMERS. SEE SHEET P-3.1,DETAIL 8.FLOOR SINK- J.R. SMITH MODEL #3150Y03-PDBS, 12 1/2" X 12 1/2" X 8", "3" OUTLET.AND POLISHED ALUMINUM DOME STRAINER. USE DEEP SEAL P-TRAPS ON FLOOR SINKSW/TRAP PRIMERS. IF APPROVED BY AUTHORITY HAVING JURISDICTION, THE P.C. MAY USEPROSET TRAP GUARDS IN LIEU OF TRAP PRIMERS. SEE SHEET P-3.1,DETAIL 8.1 1/2"HB1HB2_ _ _3/4"HOSE BIBB- WOODFORD MODEL B65, CHROME FINISH, VACUUM BREAKER, LOOSE KEYOPERATES HYDRANTS-TURN KEYS OVER OWNERS, AND WALL CLAMP. MOUNT AT 36" OFFFINISHED FLOOR OF BUILDING. SEE SHEET P 3.3, DETAIL 2.HOSE BIBB- ACORN 8104 SINGLE TEMP. WITH VACUUM BREAKER, HOSE BOX W/DOORAND FRAME, LOCKABLE-TURN KEYS OVER TO OWNERS, AND WALL CLAMP. MOUNT AT 18"OFF FINISHED FLOOR OF BUILDING.DSCDRDOD_ __ __ ___ __ ____OVERFLOW DRAIN- J.R. SMITH NO. 1080Y-RC-CID CAST IRON ROOF DRAIN WITHFLASHING CLAMP, SUMP RECEIVER, UNDER DECK CLAMP, CAST IRON DOME AND 2" HIGHDAM. SEE PLANS FOR OUTLET SIZE. SEE PLUMBING SHEET P-3.2.DOWNSPOUT NOZZLE- J.R. SMITH NO. 1770 WITH FLANGE, NICKEL BRONZE, MOUNT AT12" OFF FINISH GRADE, TO DISCHARGE ON TO CONCRETE SPLASH BLOCKS. SEE PLANSFOR SIZE AND LOCATION, SHEET P-3.2.CANOPY DRAIN- J.R. SMITH NO. 1520T-NB, 90° FLUSH GRATE, WITH FLASHING CLAMPFLANGE, NICKEL BRONZE, MOUNT IN GUTTER AT FRONT CANOPY, SEE ARCHITECTURALDRAWINGS FOR EXACT LOCATION. E.C. TO PROVIDE HEAT TRACE IN GUTTER AND THRUPIPING OUT TO DAYLIGHT IN CURB. SEE SHEET P-3.1, DETAIL 16._CLAMP, SUMP RECEIVER, UNDERDECK CLAMP AND CAST IRON DOME. SEE PLANS FOROUTLET SIZE. SEE PLUMBING SHEET P-3.2.ROOF DRAIN- J.R. SMITH NO. 1010Y-RC-CID CAST IRON ROOF DRAIN WITH FLASHING _ARRESTERS, #5005 PDI-A 1-11 FIXTURE UNITS, 3/4" THRU # 5030 PDI-B 61-113 FIXTUREWHAUNITS, 1".3/4"/1"_ _3/4"/1"WATER HAMMER ARRESTERS- J. R. SMITH "HYDROTROL" HEAVY DUTY WATER HAMMER1/2" 1/2" 2"1 1/2"_ _ _3/4"3"P17___DOMESTIC WATER BOOSTER PUMP - GRUNDFOS MODEL MPC-E 2CRE 15-1, 2HP, 3 PH, 208 VOLTS, 20 PSI BOOST, 90 GPM, INLET PRESSURE 54 PSI, STAINLESS STEEL BASEAND FRAME, MANIFOLD 316 STAINLESS STEEL, NEMA 4 RATED PANEL, N/E SWITCHES,SERVICE DISCONNECT SWITCHES, SURGE PROTECTION, PUMP RUN LIGHTS, ALARMCIRCUIT, AND IO3501 INPUT/OUTPUT MODULE. PROVIDE AND INSTALL AMTROL ST-60V-C25 GALLON INPUT. PROVIDE FACTORY START-UP.1/2" 1/2"2"1 1/2"SYMBOLWDESCRIPTIONVCW HWPLUMBING FIXTURE SCHEDULEEQUIPMENT AND INSTALLATION BY PLUMBING CONTRACTOR1/2" 1/2"2"1 1/2"P18AIR COMPRESSOR - NOT USED.____WATER COOLER (A.D.A.) - NOT USED.BACKFLOW PREVENTER- WATTS LF 009M2QT-S REDUCED PRESSURE BACKFLOWPREVENTER, IN LINE CHECK VALVES, TEST COCKS, 2-SHUT OFF VALVES, WITH BRONZESTRAINER. PIPE DRAIN TO FLOOR DRAIN IN THIS ROOM. INSTALL 24" OFF FINISHED FLOOR.PRESSURE REDUCING VALVE- WATTS LF223, WITH BYPASS FOR THERMAL EXPANSION, SET REGULATOR FOR MINIMUM OF 55.5 PSI AT THE OUTLET, PROVIDE 0-200 PSI-2 1/2"FACE-PRESSURE GAUGE, AND BALLVALVES ON THE INLET AND OUTLET SIDE OF VALVE.INSTALL VALVE AT 48" OFF FINISHED FLOOR. SEE SHEET P-3.0, DETAIL 1.P19____AIR REEL - NOT USED.LAVATORY - NOT USED.A/C UNITROOF TOPDRIPCONDENSATEPIPING ON ROOFVENTED TRAP3" DEEPPANCONNECT TO CONDENSATEDRAIN AT UNITROOF LINEPAINT ALL EXPOSED GASPIPING WITH 1 COAT OFPRIMER & 1 COAT OF PAINT.TOTAL FUWATER FUQUANTITYFIXTURECOLDHOTWASTE FU TOTAL FUFIXTURE UNIT - 2018 IPCP1 WATER CLOSET (ADA)24.0 8.0-P2 WATER CLOSET 44.016.0-P3 URINAL (ADA)12.0 2.0P4 URINAL 12.0 2.0P5 LAVATORY (ADA)21.0 2.0P6 LAVATORY P7 MOP SINK13.0 2.25 3.0 3.02.25P8 BAR SINK42.0(2)2.04.01P9 3 COMP. SINK14.03.0-3.0P10 WATER FILTER12.0 2.0--P12 WATER HEATER1- - - --P14 R.P.Z.1- - - --P15 GREASE INTERCEPTOR1- - - --P16 H.W. HEAT TRACE1- - - ----P13 P.R.V.1- - - --P11 WATER COOLERIWIW6.0 6.001.0 1.02.0--(2)2.0IW10.010.040.020.05.0 5.05.02.0 3.0 3.0FD1 FLOOR DRAIN7--3.021.0-FS1 FLOOR SINK6- -2.0 12.0-FS2 FLOOR SINK2- -3.0 6.0-HB1 WALL HYDRANT32.5 + 1.0 4.5- --HB2 WALL BOX HYDRANT21.0 2.0- --KITCHEN EQUIPMENT41.0 4.0- --TOTAL 112.097.75 14.2576.0-05.02.0P18 BOOSTER PUMP1- - - --1.0-- -FLOORTO BOOSTERPUMPFROMCITYWATER(UNDERGROUND)PRESSUREREDUCINGVALVE (P13)BACKFLOW PREVENTER(P14)STRAINERSHUTOFF VALVETHE 2" DOMESTIC WATER SERVICE LINE SHALL BE ENCASEDIN A PIPE SLEEVE (4" MINIMUM SIZE PIPE, PVC OR ABS),FROM 18" OUT PAST THE HOUSEKEEPING PAD TO A MINIMUM OF 6" ABOVE THE SLAB INSIDE OF THE BUILDING. THE JOINTSIN THE SLEEVE SHALL BE SEALED TIGHT. SLEEVE PIPE AS IT PASSES THRU CONCRETE. SEAL BETWEEN PIPE AND SLEEVEWATTS AIR GAP,PIPE TO FLOOR DRAINW/ PROPER AIR GAPSHUTOFF VALVEPRESSURE GAGE0-120 PSI, LIQUIDFILLED2"2"2"UNIONS EACH SIDE OF PRV(P13)EODNEAROLOCIGNELAOISSEFDERETSIGER NORP R27241A.NIEL SONGORDON PROJECT NUMBER:185 S. State Street | Salt Lake City, Utah 84111SHEET NUMBERSHEET NAMEDRAWN BY: APPROVED BY:DRAWING ISSUEPROTOTYPE VERSION:THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC.DESCRIPTIONARCHITECT:ENGINEER:STAMP:ISSUANCEDATEConsulting EngineersThis document and the ideas and designs incorporated herein, as an instrument of professional service, is the property of NIELSON ENGINEERING, INC. and is not to be used, in whole or in part,for any other project without the written authorization of an authorized representative of NIELSON ENGINEERING, INC. Unauthorized use will be prosecuted to the fullest extent of the Law.Copyright c 2021 by: NIELSON ENGINEERING, INC.Nielson Engineering, Inc.OWNERSHIP OF DOCUMENTS156 North Twelfth AvenuePocatello, Idaho 83201PHONE (208) 232-2577FAX (208) 234-09184/30/2021 1:57:40 PMPLUMBINGSCHEDULES,NOTES & DETAILS19335PERMIT SET 4/30/21BH ApproverP-3.0MAVERIK, INC.I-25 & E. COUNTY ROAD 32FT COLLINS, COMAVERIK C-STORESCALE: NONEP-3.0DOMESTIC WATER LINE ENCASEMENT DETAIL3SCALE: NONEP-3.0ICE BIN DRAIN LINE DETAIL4SCALE: NONEP-3.0TRAP PRIMER DETAIL5SCALE: NONEP-3.0PIPING AT ROOF TOP UNITS DETAIL2SCALE: NONEP-3.0PRV STATION PIPING DETAIL1 21SHOULD HAVE A FIXURE-UNITON MULTIPLE FIXTURE BRANCHLINES UP TO 20 FEET IN LENGTH,INSTALLED ON THE BRANCH LINEBETWEEN THE LAST TWO FIXTURESBEING SERVED. THE ARRESTORCONNECTED TO THE BRANCH LINE.THAN THE TOTAL FIXTURE-UNITSSHOULD BE EQUAL TO OR GREATERTHE ARRESTOR ON EACH BRANCHOF THE FIXTURE-UNITS RATINGS OFCONNECTED TO THE BRANCH LINE.ON MULTIPLE FIXTURE BRANCHLINES OVER 20 FEET IN LENGTH,TWO ARRESTORS SHOULD BE USEDON EACH LINE WITH THE SECONDUNIT PLACED AT THE APPROXIMATEMIDPOINT OF THE LINE. THE SUMRATING EQUAL TO OF GREATER THANWATER CLOSETSWATER CLOSETSURINALSFLOORLAVATORIESLAVATORIESFLOORWATER HAMMERUP TO 20 FEET(TYP.)ARRESTORTHE TOTAL FIXTURE-UNITSTHE ARRESTOR SHOULD BENOTESOVER 20 FEETSHEET METALSCREWUNISTRUTCLAMP1" TYPE MCOPPER PIPEHEAT TRACE INUNITS 32° F &BELOWFREEZER ORCOOLER WALLUNISTRUTCLAMP1 5/8" X 7/8"THICK UNISTRUTCHANNEL1 5/8" X 7/8"THICK UNISTRUTCHANNEL1" TYPE MCOPPER PIPEHEAT TRACE INUNITS 32° F &BELOW1/2" THICKARMAFLEXINSULATIONWITH SEALEDJOINTS1 5/8" X 7/8"THICK UNISTRUTCHANNELFREEZER ORCOOLER WALLSHEET METALSCREWSUNISTRUTCLAMPFLOOR CLEANOUTLONG SWEEPFITTINGS2" PIPESINK2" OR 3" PIPE2" WALL CLEANOUTFOOT VENT45° FITTINGSLOPESLOPE2" PIPE2" PIPE2" PIPE2" VENT THRU ROOFWALLNOTE:RAISE RETURN VENT ASHIGH AS POSSIBLE UNDERTHE DRAIN BOARD. USE2(45°) FITTINGS AND ONELONG RADIUS ELBOW TOMAKE LOOP. INSTALL LONGSWEEP FITTINGS BELOWFLOOR AND RUNHORIZONTALLY TO NEARESTPARTITION. USE 45°FITTINGS FOR EASYSTOPPAGE CLEANING.FLOOR CLEANOUT (FCO)CLEANOUT TO GRADE (COTG)WALL CLEANOUT (WCO)FLOOR LINEWALLWASTE LINEFLOOR LINEBALANCE OF PIPINGSAME AS COTGBRASS C.O. PLUG W/COUNTER-SUNK HEADFINISHED GRADE16" SQ. CONCRETE PAD.TROWEL SMOOTH ANDBEVEL EDGES.CI WASTE LINE.LENGTH TO SUIT1/8 CIBENDCLEANOUT AND ACCESS COVER.TOP OF COVER TO BE FLUSH W/TOP OF FLOORCHROME WALLCOVER ANDSCREWMAY EXTEND ASWASTE OR VENTCLEANOUT TEEW/ PLUGBALANCE OF PIPINGSAME AS COTG6"1/8 CI BEND1/8 CI BENDSTRUCTURAL SLABCONCRETE FILLFLOOR DRAINNOTE:ALL FLOOR DRAINS SHALL HAVE A DEEP SEAL P-TRAP OR A TRAP PRIMER AS PER CODE REQUIREMENT. IF APPROVED BY LOCAL AUTHORITY HAVING JURISDICTION PROSET TRAP GUARD MAY BE INSTALLED.TILE FLOORWHERE INDICATEDCEMENT BEDWHERE INDICATEDOUTLET TOP-TRAPTRAP PRIMERNOTE: INSTALL SINKTO ROUGH WALL.4'-3"3'-0"WALL FAUCETS FORCHEMICAL CLEANINGSYSTEM.JANITOR (MOP) SINKJANITOR SINK FAUCET8"3"ABOVE THESE FAUCETS.THE P.C. SHALL PROVIDE THEPROPER BACKFLOW PROTECTIONFOR THE CHEMICAL FAUCETS ANDAS PER THE LOCAL PLUMBING CODESAND LOCAL HEALTH DEPARTMENT.OWNER FURNISHED CHEMICAL FEEDER,PROVIDE WATTS #601S C.V.STAINLESS WALL COVERING(MIN)2X PIPE DIA.THE LOCAL HEALTH DEPT. REQUIREMENTSDIRECTION OF THE BUILDING CODE ANDNOTE: INSTALL FLOOR SINK AS PER THEFLOOR SINKOUTLET TO P-TRAPALUMINUM DOME STRAINERCONCRETEALL FLOOR SINKS SHALL HAVE ATRAP PRIMER OR A TRAP SEAL.FINISHED FLOOR MATERIALSFINISHED FLOOR MATERIALSINSTALL DEEP SEAL P-TRAPS ON ALLFLOOR SINKS.UNIONCOOLING COILPIPING SUPPORTSAT 5' O.C. AND ATCHANGES INDIRECTION. SLOPE MIN.1/4"/FT.WALK-INCOOLERORFREEZERRUN TO BACK WALL& ROUTE ALONGWALLS TO RECEPTORVENT WHENREQUIREDESCUTCHEONAIR GAPFLOOR SINK2X PIPE DIA.NOTE"PIPE MATERIAL TO BE MINIMUMOF M TYPE COPPER PIPE.INDIRECT WASTE SCHEDULEINDIRECT WASTE LINE TO RECEPTORTYPICAL METHODS FOR RUNNINGCONNECTIONAT CASELOCAL AUTHORITY.BELOW RIM IF APPROVED BYNOTE: I.W. LINE MAY TERMINATEENDS OPENVERTICAL TEE WITH BOTHDISCHARGE POINTOPEN TEE TO BE BELOW CASEFLOOR SINKDRAIN LINESUPPORTEDAS SHOWNVENT AS REQUIRED2X PIPE SIZEOUTLET.LGR. THANPIPE SIZEMIN. ONE1/2" I.D.LESS THANBUT NOTOUTLETSAME ASYESNONOYESYESNOOVER 15'5'-15'0-5'SIZEPIPEREQ'DVENTREQ'DTRAPLENGTHPIPE2X PIPE SIZEFLOOR SINKVENT AS REQUIREDTRAPTRAPCONNECTIONAT CASE1-1/2"1-1/2"3"1-1/2"FAUCETHOLESNOTE:ALL INSIDE CORNERSRADIUSED TO MEETN.S.F. SPEC'S.3" WCOFS2TO GREASE INTERCEPTORFAUCET TO BE ON DOWNSTREAM SIDE OF CHECK VALVES2" VENT1234FEMALE x FEMALELONG SWEEPBEND (TYPEACH END)COUPLERNOTES:EXTEND MIN.7" THRU SLAB4" 0 MIN. PVC PIPEw/ PULL CORD ENTIRERUN OF PIPE. FOR BEVERAGE100' MAX.CHASESLABBEVERAGE LINEFOAM CAP FOR4"∅X 6" PROVIDE AND INSTALLTEMPORARY CAPOVER EACH RISER(USE NO CEMENT)A.BEVERAGE LINES.CO LINES. W/ PULL CORD2" ∅MIN. PVC PIPE ENTIRE RUN OF PIPE.B.2CONDUIT SUPPLIED AND INSTALLED BY P.C.USE OF TEES, SHORT SWEEP 45° AND 90° ELLS IS NOT ALLOWED.CONDUIT SHALL BE LAID IN STRAIGHT RUNS BETWEEN RISER POINTS WITHTHE USE OF ONLY TWO LONG SWEEP 90° ELLS. (36" MINIMUM RADIUS)INTERIOR OF CONDUIT SHOULD BE SMOOTH WITH NO SHARP OR ROUGHJOINT EDGES TO HANG UP BEVERAGE TUBING.PULL CORDPULL CORDROOFING MATERIALGUTTER DRAIN3" DISCHARGE LINEGUTTER PAN3"∅N.H.NOTEP.C. TO CONNECT TO THE TRANSITION BETWEEN THE RAIN GUTTER PANAND THE 3" N.H. CONNECTION PROVIDED BY THE G.C. P.C. TO CONNECTTO THIS 3" N.H. TRANSITION PIECE AND RUN OUT OF BUILDING.DOWN IN COLUMNPROVIDE GASKET/GROMMETSEAL GUTTER END CAPOR SEAL WITH HYDROMET"ULTRA SET" MASTIC.NOT IN WALLRUN IN COLUMN &OUT TO STORMSEWER3'4"x 5'0"10' 4" x 5' 0"6' 8"x 5' 0"48"56"12"6"6"2'-0"12"4"12"4"4"6"12"12"12"45"4"12"NOTE:ALKALI PORTLAND CEMENT.COMPRESSIVE STRENGTH,6 GAL/SACK PORTLANDCEMENT. 4000 PSI MIN.ASTM C 150, II/V LOW- CONSTRUCTION AND CAPACITY ARE ACCEPTABLE. PROVIDE SHOP DRAWINGS PRIOR TO ORDERING. 1,500 GAL./MIN.2. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO ADMINISTRATIVE AUTHORITIES FOR APPROVAL PRIOR TO ORDERING OR FABRICATING.EXTENSIONS (24" DIA) SUCH AS AMCOR OR& LENGTH OF COVER4" INLETLAT. ENTIRE WIDTHLONG. #6 BAR 6" O.C.#4 BAR 12"0.C.1. PREFABRICATED UNIT SITE-BUILT OF SIMILARNOTES:REINFORCED CONCRETE(EXTRA HEAVY DUTY TRAFFIC)TO SUIT LOCAL STANDARDS.RING (TYP OF 2). PATTERNC.I. MANHOLE COVER ANDBOTTOM & SIDES#4 BAR 12" O.C. BOTH WAYS1,500 GAL. CAPACITYSOIL (95% PROCTOR)SET ON COMPACTEDPAVEMENT4" DISCHARGETO BUILDING3" VENT6" REINFORCED CONCRETE PADFROM MANHOLESSLOPE PAVEMENT AWAY(IN PAVED AREAS)COTG2" VENT# MEAL (330) X WASTE RATE (2) X RETENTION TIME (1.5) X STORAGE FACTOR (1.5) = 1.485 GAL.CAPHANGERSDOUBLE NUTTHREADED RODCOPPER CLEVISB-LINE B3100FB-LINE B3100CPIPEOR COLD WATERDOMESTIC HOTINSULATIONINSULATION (TYP.)HOT WATER LINECOLD WATER LINENOTE:USE SIMILAR HANGERS FORSTEAM, CONDENSATE, ANDAIR LINES.EPOXY COATED UNISTRUT-LENGTH VARIESDEPENDING ON LINE SIZES, NUMBER OF LINES,AND THE NUMBER BEING SUPPORTED.UNISTRUT CHANNEL: B-LINE B22-GRNUNISTRUT CLAMPS: B-LINE B2000 SERIES COPPERTUBING CLAMP OR B-LINE BVT SERIES VIBRA CLAMP.ATTACH 1/2" ALL THREADRODS TO MEMBER (TYP.)CONDUIT FOR ELECTRICALWIRING OR OTHER PIPINGCOATED ORHANGERSWALL CLEANOUT WITH COVERURINALFLUSH VALVEWALL3" MINIMUM SIZE FROMMAIN WASTE LINE TOBOTTOM OF TRAP ARMON URINAL ADA17" MIN.STANDARD24" MIN.2"3"3"3" OR 4"2"4"EODNEAROLOCIGNELAOISSEFDERETSIGER NORP R27241A.NIEL SONGORDON PROJECT NUMBER:185 S. State Street | Salt Lake City, Utah 84111SHEET NUMBERSHEET NAMEDRAWN BY:APPROVED BY:DRAWING ISSUEPROTOTYPE VERSION:THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC.DESCRIPTIONARCHITECT:ENGINEER:STAMP:ISSUANCEDATEConsulting EngineersThis document and the ideas and designs incorporated herein, as an instrument of professional service, is the property of NIELSON ENGINEERING, INC. and is not to be used, in whole or in part,for any other project without the written authorization of an authorized representative of NIELSON ENGINEERING, INC. Unauthorized use will be prosecuted to the fullest extent of the Law.Copyright c 2021 by: NIELSON ENGINEERING, INC.Nielson Engineering, Inc.OWNERSHIP OF DOCUMENTS156 North Twelfth AvenuePocatello, Idaho 83201PHONE (208) 232-2577FAX (208) 234-09184/30/2021 1:57:49 PMPLUMBING DETAILS19335PERMIT SET4/30/21BHApproverP-3.1MAVERIK, INC.I-25 & E. COUNTY ROAD 32FT COLLINS, COMAVERIK C-STORESCALE:NONEP-3.1WATER HAMMER ARRESTOR INSTALLATION DETAIL1SCALE: NONEP-3.1CONDENSATE PIPING DETAIL 12SCALE: NONEP-3.1CONDENSATE PIPING DETAIL 23SCALE: NONEP-3.1ISLAND SINK INSTALLATION DETAIL4SCALE: NONEP-3.1CLEANOUTS DETAIL5SCALE: NONEP-3.1FLOOR DRAIN (FD1) DETAIL6SCALE: NONEP-3.1ELEVATION AT MOP SINK DETAIL7SCALE: NONEP-3.1FLOOR SINK (FS1 & FS2) DETAIL8SCALE: NONEP-3.1REFRIGERATION CONDENSATE DRAIN DETAIL10SCALE: NONEP-3.1TYPICAL INDIRECT WASTE DRAIN DETAIL11SCALE: NONEP-3.13 COMPARTMENT SINK & SAN. CONN. DETAIL13SCALE: NONEP-3.1BEVERAGE & CO 2 SUPPLY CONDUIT DETAIL14SCALE: NONEP-3.1CANOPY GUTTER DRAIN DETAIL15SCALE: NONEP-3.1GREASE INTERCEPTOR (1,500 GAL.) DETAIL12SCALE: NONEP-3.1PIPE HANGING METHODS DETAIL9SCALE: NONEP-3.1URINAL PIPING DETAIL16 P9P8P8P7P12P10P8HB1HB1HB1HB2HB2TO CITYWATER3/4"CW1"CW1/2"CW1/2"CW1 1/4"CW1 1/4"CW1 1/4"CW1 1/4"CW1/2"CW1 1/2"CW2"CW1 1/4"CW3/4"CW1"CW1/2"CW2"CW1/2" HW1/2" HW1" HW1 1/4" HW1 1/4" HW1 1/4" HW1 1/4" HW1 1/2" HW1/2" HW1/2" HW1" HW2"CW1 1/2"CW1/2"CW1/2" HW3/4" HW3/4"CW1/2"CW1 1/4"CW1/2"CW1 1/2"CW3/4"CW1/2"CW1 1/4" HW3/4"CW1/2" HW2"CW3/4" HW3/4"CWP1P2P2P2P3P5P5P1P4P13 & P14& BUILDING MAIN SHUTOFF VALVE3/4"CW1 1/4"CW1 1/4"CW1"CW1"CW1/2"CW3/4"CW3/4"CW3/4"CW1 1/4"CW3/4"CW3/4"CW3/4" HW1/2" HW1/2" HW1/2" HW1/2" HW1/2" HW1/2" HW3/4" HW1 1/2"CWP21 1/4"CW3/4"CW3/4"CW2"CW2"CWMAIN SHUTOFF VALVETO FUEL CANOPY NOTE:THE P.C. SHALL INSTALL THE CONDENSATE PIPING FROM EACHROOF TOP UNIT, ON THE SIDE OF THE RTU WHICH IS THE SIDEWHERE THE ROOF DRAIN ARE LOCATED. PROVIDE THE PROPERDEPTH OF THE TRAP (MINIMUM OF 3") AND DISCHARGE THECONDENSATE ONTO THE ROOF, WHICH WILL RUN TO THE ROOFDRAINS.BASED ON 2.0" RAINFALL PER HOUR & 1/8" SLOPEROOF DRAIN CALCULATIONSFLAT ROOF:#1PARAPETS:658 SQ. FT. /2 314 SQ. FT.1,716 SQ. FT. =FLAT ROOF:#2PARAPETS:275 SQ. FT.84'-6" X 3'-3" 275 SQ. FT. 656 SQ. FT.32-0" X 20'-6" 656 SQ. FT. ==63 SQ. FT.1,402 SQ. FT. 1,339 SQ. FT.31-6" X 2'-0" =42-6" X 31'-6" =177 SQ. FT.627 SQ. FT. 450 SQ. FT.16-10" X 6'-0" =138-6" X 3'-3" =275 SQ. FT. /2 138 SQ. FT.794 SQ. FT. =PIPE, FITTINGS, AND VALVES TO BE USED TO INSTALL THE OWNER FURNISHED"RO" FILTER WATER SYSTEM (NO SUBSTITUTES ALLOWED).PIPE: WIRSBO "AQUAPEX" WHITE TUBING, ENGEL METHOD PEX OR PEX-a TUBING.FITTINGS: WIRSBO "EP" FITTINGS, ProPEX STAINLESS STEEL MALE THREADEDADAPTER (Q8525050) WITH ProPEX SLIP RING (W/EXPANDER TOOL).SHUTOFF VALVES: PARKER HANNIFIN "TRUESEAL" BALLVALVE MODEL PP6VME8-MG 1/2"NPTF THREAD X 3/8" OD TUBING, 1/2" STAINLESS STEEL COUPLING, AND ESCUTCHEON.NOTE: DO NOT USE ANY MALLEABLE METAL PIPE OR FITTING,BRASS OR BRASS FITTINGS, OR COPPER PIPE AND FITTINGS IN THE"RO" PIPING SYSTEM. ALL PIPE AND FITTING MUST BE APPROVEDFOR "RO" WATER.SUPPLIES: PIPING FROM PARKER HANNIFIN BALL SHUTOFF VALVE ON "RO" FILTERSYSTEM TO THE OWNER SUPPLIED EQUIPMENT (ICE MAKERS, COFFEE UNITS,CARBONATORS, & ETC.) SHALL BE PARKER-HANNIFIN "SERIES E" POLYETHYLENE"NATURAL" TUBING WITH PARKER-HANNIFIN "TrueSeal" FITTINGS.NOTE: PIPE, FITTINGS, AND TUBING FORTHE "RO" WATER SYSTEMP1043A9C20A17A72.1(2)9C1/2" FWIN 4" PVCTO EACHISLAND38 (2)184219611095113/4"FW1/2"FW3/4"FW3/4"FW3/4"FW3/4"FW3/4"FW1/2"FW1/2"FW1/2"FW3/4"FW1/2"FW3/4"FW3/4"FW1/2"FW1/2"FW1/2"FW3/4"FW1/2"FW3/4"FW3/4"FW3/4"FWDSCOTGRDOD#21,797 SQ. FT.3" VTR4,760 TOTAL SQ. FT.OD6"4"4"RT-1150 MBHRT-2150 MBHRT-3130 MBH3/4"G3/4"G4" VTR3/4"G#12,963 SQ. FT.RD6"4"4"4"4"4"4"4"A23445BCDE13.53" VTRCOCO444P9SAMPLINGMANHOLE1500 GALLONGREASEINTERCEPTORP15TO CITYSEWERSYSTEMCOTGCOTG(2)COTGCOTG3"VTR4"VTRFD1FD1FD1FD1FD1FS1FS1FS2FS2P8P8P8P7P12P10P8P1P2P2P3FS13"GR4"GR3"GR4"GR3"GR3"GR3"GR3"4"3"2"V2"V2"V3"V1 1/2"V1 1/2"V1 1/2"V1 1/2"V2"V2"V2"V3"V3"V1 1/2"V3"V2"V1 1/2"VP51 1/2"VFS1FS11 1/2"V1 1/2"V2"V2"V2"GR3"GR3"GR3"GR4"FCO1 1/2"V2"V4"V2"3"GR3"GR3"GR3"GR2"GR3"GRFD13"GR2"4"4"3"V1 1/2"V3"V2"V2"V1 1/2"V2"V2"V1 1/2"V1 1/2"VP5P2P2P13"GR3"GR3"GR3"GR3"GR2"GR1 1/2"VFS11 1/2"VP44"4"4"2"V3"V3"V3"V2"V4"GR4"GR4"4"3"V3"VTR4"4"4"4"GR4"GR3"V2"V3"V2"V3"V3"V2"VNOTE:SEE SHEET P-1.0FOR EXACT LOCATIONOF GREASE INTERCEPTOR& SAMPLING MANHOLEFS14"GR2"GREODNEAROLOCIGNELAOISSEFDERETSIGER NORP R27241A.NIEL SONGORDON PROJECT NUMBER:185 S. State Street | Salt Lake City, Utah 84111SHEET NUMBERSHEET NAMEDRAWN BY: APPROVED BY:DRAWING ISSUEPROTOTYPE VERSION:THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC.DESCRIPTIONARCHITECT:ENGINEER:STAMP:ISSUANCEDATEConsulting EngineersThis document and the ideas and designs incorporated herein, as an instrument of professional service, is the property of NIELSON ENGINEERING, INC. and is not to be used, in whole or in part,for any other project without the written authorization of an authorized representative of NIELSON ENGINEERING, INC. Unauthorized use will be prosecuted to the fullest extent of the Law.Copyright c 2021 by: NIELSON ENGINEERING, INC.Nielson Engineering, Inc.OWNERSHIP OF DOCUMENTS156 North Twelfth AvenuePocatello, Idaho 83201PHONE (208) 232-2577FAX (208) 234-09184/30/2021 1:58:06 PMPLUMBINGISOMETRICDRAWINGS & ROOFDRAINS19335PERMIT SET 4/30/21BH ApproverP-3.2MAVERIK, INC.I-25 & E. COUNTY ROAD 32FT COLLINS, COMAVERIK C-STOREP-3.22PLUMBING COLD & HOT WATER SCHEMATICP-3.2 KEY NOTES1 SEE SHEET P2.0 FOR WASTE PIPING, STORM WATER PIPING, INDIRECT WASTE PIPING, &CONDENSATE PIPING.2 SEE SHEET P2.1 FOR WATER PIPING AND KITCHEN EQUIPMENT HOOK-UPS.3 SEE SHEET P2.2 FOR FILTERED WATER PIPING AND EQUIPMENT HOOK-UPS.4 THE P.C. SHALL RISE UP TO 3' ABOVE THE INTAKE OF ROOFTOP UNITS IF THE V.T.R. MUSTBE WITHIN 10'-0" OF THE UNIT INTAKE.23P-3.23PLUMBING FILTERED WATER SCHEMATIC1/8" = 1'-0"P-3.24PLUMBING ROOF DRAIN PLANN1P-3.21PLUMBING WASTE & VENT SCHEMATIC MOP SINK1" PVC PIPEDRAIN OFFFILTER SYSTEMSTUB BLUE PIPEMINIMUM OF 10"INTO PVC DRAINPIPEPIPE STRAPS(TYP.)AIR GAPFILTER SYSTEMINSIDE WALLBRASS CASINGADJUSTABLEWALL CLAMPWALL FACEWALL OPENINGTEE KEYHANDLE.(KEY TO OWNER)ASSE APPROVEDVACUUM BREAKER-PREVENTER WITH3/4" HOSECONNECTIONNOTE:IN LOCATIONS WHERE OUTSIDETEMPERATURE DOES NOT FALLBELOW 32 DEGREES F.,INSTALLATION OF HOSE BIBBWITHOUT FREEZE PROTECTION IS ACCEPTABLE. REFER TO PLUMBING FIXTURE SCHEDULE.(CONFIRM WITH ENGINEER)NOTE:KEYS TO BE TURNEDOVER TO OWNER.CONVENIENCE STORE EQUIPMENT SCHEDULECWNUMBERDESCRIPTIONWHWVIWREMARKSFWEQUIPMENT SUPPLIED & SET BY SUPPLIER INDICATED ON FACILITIES EQUIPMENT DRAWINGS (EQ). ALL PLUMBING ROUGH-IN & FINALPLUMBING CONNECTIONS BY PLUMBING CONTRACTOR. REFER TO EQ. DRAWINGS FOR EXACT ROUGH-IN, CONNECTION REQUIREMENTSLOCATIONS & DIMENSIONS. ALL HOT & COLD WATER CONNECTIONS TO EQUIPMENT SHALL BE MADE THRU VALVES OR STOPS EQUALTO THOSE SPECIFIED FOR PLUMBING FIXTURES AND BRAIDED STAINLESS STEEL CONNECTORS.1117A183843A511920A472.12133969CCAPPUCCINO MACHINEQUIETQUBE ICE MAKERQUIETQUBE ICE MAKERWATER BOOSTER"RO" WATER FILTRATION SYSTEMSTAINLESS STEEL SINK (HAND OR BAR)-- -- -- --- --- -VENDOR TO INSTALLBEYOND CW SUPPLY STOP1/4"FROMSTOPTOFLR.SINK3/8"FROMSTOPTOFLR.SINKTOFLR.SINKINSTALLED ON 17DCONNECT TO 17C3/8"FROMSTOP-PROVIDE FILTER WATER TO THEBACK OF THE UNIT.3/8"3/8" TO #4, DRINK DISPENSER1/2"TO1/2"1 1/2" 2"STOPTOFLR.SINKDIRECT & INDIRECT DRAINED (SEE PLAN)1/2"BUNN DUAL THERMOFRESHVENDOR TO INSTALLBEYOND CW SUPPLY STOP- - -3/8"FROMSTOPTOFLR.SINKWITH 12" FIN OPPOSITE SIDEFROM DRAIN BOARD.)1/2"-1 1/2"TOFLR.SINK1/2"OVEN/PROOFER (NU-VU-OP-4/8M)FROZEN CARBONATED BEV. (ICEE)- -3/8"FROMSTOPTOFLR.SINKVENDOR TO INSTALLBEYOND CW SUPPLY STOP3 COMP. SINK W/TWO FAUCETS-ICE/BEVERAGE DISPENSER- -5'-1" L x 32 1/2"H3/4"TOFLR.SINK1/4"FROMSTOP--------------BLOCKING REQUIREDSEE DRAIN DETAIL 1/P 2.2.MIN.3/4"MIN.1/2"MIN.3/8"3/4"MIN.--PROVIDE FILTER WATER TO THEBACK OF THE UNIT.NUGGET ICE MAKER-3/8"FROMSTOP-TOFLR.SINK---TWO DOOR FREEZER--TOFLR.SINK-PROVIDE FILTER WATER TO THEBACK OF THE UNIT.--F' REAL FREEZER--TOFLR.SINK1/2"FROMSTOPINDIRECT DRAIN TO FLOOR SINKBELOW WITH AIR GAPW/ AUTOMATIC ICE BAGGER & DISPENSERVENDOR TO INSTALLBEYOND CW SUPPLY STOP- - -3/8"FROMSTOPTOFLR.SINK-110TEA BREWERMOUNT AT 95" A.F.F.FULL PORT BALL VALVELEGENDNOTES:T&P RELIEF VALVE SETSAME AS HEAT INPUTRATING OR 150 PSIAS PER ENERGY CODE INSTALLHEAT NIPPLES ON HOT & COLD SUPPLIESMOP SINKPIPE T&P, WATER HEATER PAN,AND CONDENSATE DRAIN RUN SEPARTATELY TO MOP SINKCEILINGFINISHEDFLOOR1 1/2"HOT WATERTO FIXTURESUNISTRUTPROVIDE & INSTALL SEISMICBRACING TO WALL (TYP.)SUCH AS MANUFACTURED BYSPACEMAKER (712) 542-4699WATER HEATER PAN & DRAIN14" WATER HEATER STANDCOLDWATERSUPPLYPVCINTAKE & EXHAUSTGAS LINEWALLCHECK VALVEUNIONDRAINTEMPERATURE & PRESSURERELIEF VALVEGAS VALVESTORM KING "HYDROCLAW" BRACKET.36" A.F.F.4" PVC CAP-(DO NOTGLUE) DRILL HOLESFOR PEX PIPES.4" PVC PIPE SLEEVESUPONOR PEX PIPE1/2" BALL VALVES (TYP.)UNISTRUT W/CLAMPS3/4" HW3/4" CW3/4" FWEODNEAROLOCIGNELAOISSEFDERETSIGER NORP R27241A.NIEL SONGORDON PROJECT NUMBER:185 S. State Street | Salt Lake City, Utah 84111SHEET NUMBERSHEET NAMEDRAWN BY: APPROVED BY:DRAWING ISSUEPROTOTYPE VERSION:THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC.DESCRIPTIONARCHITECT:ENGINEER:STAMP:ISSUANCEDATEConsulting EngineersThis document and the ideas and designs incorporated herein, as an instrument of professional service, is the property of NIELSON ENGINEERING, INC. and is not to be used, in whole or in part,for any other project without the written authorization of an authorized representative of NIELSON ENGINEERING, INC. Unauthorized use will be prosecuted to the fullest extent of the Law.Copyright c 2021 by: NIELSON ENGINEERING, INC.Nielson Engineering, Inc.OWNERSHIP OF DOCUMENTS156 North Twelfth AvenuePocatello, Idaho 83201PHONE (208) 232-2577FAX (208) 234-09184/30/2021 1:58:13 PMEQUIPMENTSCHEDULE &PLUMBING DETAILS19335PERMIT SET 4/30/21BH ApproverP-3.3MAVERIK, INC.I-25 & E. COUNTY ROAD 32FT COLLINS, COMAVERIK C-STORESCALE: NONEP-3.3WATER FILTER DRAIN DETAIL2SCALE: NONEP-3.3OUTSIDE WALL HYDRANT DETAIL3SCALE: NONEP-3.3GAS WATER HEATER DETAIL4SCALE: NONEP-3.3PEX PIPE TO ISLANDS1