HomeMy WebLinkAboutDELLENBACH CHEVROLET ADDITION, AMENDED PUD - PRELIMINARY & FINAL - 22-89 - CORRESPONDENCE - CORRESPONDENCE-CONCEPTUAL REVIEWDevelopnat Services . Planning Department April 26, 1989 Mr. Dick Gruitch Mr. Norman Hodge Architects/Engineers West 9605 Maroon Circle; Suite 215 Englewood, CO 80112 Dear Sirs: For your information, attached is a copy of the Staff's comments concerning the Dellenbach Chevrolet amended PUD Plan, which was presented before the Conceptual Review Team on April 24, 1989. The comments are offered informally by Staff to assist you in preparing the detailed components of the project application. Modifications and additions to these comments may be made at the time of formal review of this project. If you should have any questions regarding these comments or the next steps in the review process, please feel free to call me at 221-6750. Sincerely, 6� Linda Ripley Senior Planner Attachment LR/bh xc: Tom Peterson, Director of Planning Mike Herzig, Development Coordinator Jim Faulhaber, Civil Engineer I Project Planner File 300 LaPorte Avenue • PO. Box 580 • Fort Collins, CO 80522-0580 • (303) 221-6750 Y CONCEPTUAL REVIEW STAFF COMMENTS MEETING DATE: April 24, 1989 ITEM: Dellenbach Chevrolet Amended PUD Plan APPLICANT: Architects/Engineers West LAND USE DATA: Request for 3600 square foot showroom addition to an existing auto dealership. COMMENTS: 1. Since the proposed addition represents an increase in floor area greater than 2%, the plan must be submitted as an amended PUD and approved by the Planning and Zoning Board. (Planning) 2. Show building envelopes and dimensions for the addition and the modular office structure on the site plan. (Zoning) 3. There is a 12 inch water main on the College Avenue side of the project and an 8 inch water main along Mason/McClelland Street. A sanitary sewer manhole exists at the northeast corner of the site. Separate taps are required for additional buildings. (Water and Sewer) 4. The project will be assessed a street oversizing fee paid at the time of building permit. Check with Mat Baker (221-6605) to see how the fee is calculated. If new services are proposed utility drawings will be required. (Engineering) 5. Provide a letter from a registered engineer verifying that the proposed changes will not effect impervious area or existing flow patterns on the site. There is an existing detention pond at the southwest corner of the site which has been partially filled. The detention pond should be re-evaluated to determine if the fill needs to be removed. Identify the boundary of floodplain ponding if it effects this site. Contact Glen Schlueter (221-6589) for further information. (Storm Drainage) 6. The addition will need to meet fire containment requirements per Code. (Building Inspection) 7. If additional power is required, development charges will apply. The proposed addition may be located over an existing electrical service line. (Light and Power) No Text