HomeMy WebLinkAboutSOUTH SHIELDS VETERINARY CLINIC PUD - FINAL - 44-89B - SUBMITTAL DOCUMENTS - ROUND 1 - DRAINAGE REPORT (2)FINAL DRAINAGE INVESTIGATION FOR APPLEWOOD ANIMAL HOSPITAL FORT COLLINS, COLORADO Prepared for Dr. William Musslewhite 5001 South Shields Street Fort Collins, Colorado 80526 March 20, 1990 Commission No. 1180-01-01-02 CONSULTING ENGINEERS FOUNDATION ENGINEERING 320 N. Cleveland Avneue Loveland, Colorado 80537 FOUNDATION I ENGINEERING Counsulting Engineers March 20, 1990 Commission No. 1180-01-01-02 Dr. William Musslewhite 5001 S. Shields Street Fort Collins, Colorado 80526 Dear Dr. Musslewhite, The enclosed report represents the results of the final drainage investigation for the Applewood Animal Hospital, located in the Northeast Quarter of Section 3, Township 6 North, Range 69 West of the 6th P.M., Larimer County, Colorado. This investigation was based upon the proposed site development plan and plat; proposed site development construction plans; on -site observations; and available topographic information. The investigation was performed in accordance with the criteria established in the City of Fort Collins -"Storm Drainage Design Criteria and Construction Specification Standards" manual. It is our opinion that the construction of the Applewood Animal Hospital is feasible provided that the recommendations contained in the attached report and the incorporated final design are performed in accordance with the final approved plans for the project. If you should have any_.questi Respe u ly, Kevin W. tterson, FOUNDATION ENGINEERING KWP/kmp 28$4i1 lease call. 320 North Cleveland Avenue 0 Loveland, Colorado 80537 • (303) 663-0138 i • TABLE OF CONTENTS Letter of Transmittal i Table of Contents Scope 1 Site Description 1 Existing Conditions 1 Proposed Development 2 Conclusions and Recommendations 2 EXHIBITS Vicinity Map Exhibit A Calculations Exhibit B Drainage Plan/Site Plan Exhibit C Preliminary Drainage Report Comments Exhibit D ii • E S C 0 P E The following report represents the results of a drainage investigation for a proposed development to be known as the Laurie Subdivision, located on a parcel of land situated in the Northeast Quarter of Section 3, Township 6 North, Range 69 West of the 6th P.M., Larimer County, Colorado. The investigation was performed for Dr. William Musslewhite. The purpose of this investigation is to determine the effects of the proposed development on the areas existing drainage conditions and to determine the improvements, if any, and the appropriate sizing for proposed improvements so that it may be incorporated with the construction of the project. The conclusions and recommendations presented in this report are based upon the proposed site development plan and plat; proposed site development construction plans; on -site observations; and the available topographic information. The analysis was performed in accordance with the City of Fort Collins -"Storm Drainage Design Criteria and Construction Standards" manual. S I T E D E S C R I P T I O N The site is generally rectangular in shape and contains approximately eight acres, however, the sites East-West dimension is approximately 1,150 feet and its North -South dimension varies from approximately 390 feet at the westerly boundary to approximately 280 feet at the easterly boundary. The site abuts the westerly right-of-way of South Shields Street at a point approximately one-half mile south of Harmony Road. The site is located on the Burns Tributary of the Fossil Creek Drainage Basin. Only Lot 1 (Applewood Animal Hospital), is to be developed at this time. E X I S T I N G C O N D I T I O N S The site is presently used as a large residential tract with the existing structures located at the southeast corner of the site near South Shields Street. The Pleasant Valley and Lake Canal passes through the adjacent property to the north with a lateral of that ditch flowing through the site. Near the center of the site is a ravine that has been created by scouring action associated with an overflow discharge from the Canal as it flows across the site toward the South. According to the irrigation company's officials, the overflow to the ravine is designed to discharge a maximum flow of 30 c.f.s. (cubic feet per second). East of the lateral ditch passing through the site, the property slopes gently to the East toward South Shields Street at a slope of approximately 2%. The area below the ditch is irrigated and is used for pasture except for the residence and out -buildings at the southeast corner of the site. 1 The portion of the site that lies West of the ravine is not irrigated and slopes rather steeply at approximately 15% toward the Burns Tributary of Fossil Creek. The area is sparsely vegetated with ground cover consisting mainly of native grasses and sage brush. The site abuts The Ridge Subdivsion at the West and South. The site receives run-off from the properties to the North and West. For the purposes of this investigation, the area above the Pleasant Valley and Lake Canal was not considered to effect the conditions onsite since the ditch flow is controlled to the extent that there is an existing overflow structure that directs excess flow to the ravine through the site, as previously stated. The area to the North consits of approximately 10.5 acres which drains easterly to South Shields Street and then southerly along the west side of South Shields Street through the site. An area of,approximately 2.5 acres drains into the smaller side ravine that enters the site at mid -point of the northern boundary. Approximately 4.5 acres drains directly into the major ravine before it enters the site near the northwest corner. P R O P O S E D D E V E L O P M E N T The proposed construction is to consist of a vetinary clinic with associated parking that is to be located on Lot 1, situate in the northeast corner of the site adjacent to South Shields Street. A new cul de sac street is to be constructed to serve the new clinic and the existing residence. The cul de sac is to be extended to a circular turn- around west of the existing and proposed construction in order to provide access to the area to the West. At this time, development to the West is not planned, however, future development is assumed to be single family residential. C O N C L U S I O N S A N D R E C O M M E N D A T I O N S 1. The proposed development will retain the existing drainage patterns with only a culvert to be provided under Laurie Drive. 2. As South Shields will be reworked and widened to full width in the near future, and the shallow nature of the borrow ditch in which the 24" RCP is to be placed, we recommend instead the use of a 15 RCP. At the time South Shields is widened, the RCP will be abandoned. Provide for overflow of Laurie Drive due to 100 year flood. 3. The site is located in the fossil Creek Drainage Basin. The site is not located within the floodway or flood plain. 4. All development is to be performed in accordance with City of Fort Collins Standards and Specifications. 5. Onsite detention of stormwater is not recommended due to the sites proximity to the existing "Major" drainage course. 2 0 6. Additional runoff from the Applewood Animal Hospital clinic travels to the West drainage ditch, then flows south to Fossil Creek. It is our opinion that the small amount of additional runoff from the site will not require enlargement of downstream facilities. N U • Dr. Mussleshite-Laurie Subdivision By: DRM Commission No. 1180-01-01-01 Date: March 20, 1990 Calculations for Drainage Investigation for Laurie Subdivision located in the NE 1/4 of Section 3, Township 6 North, Range 69 West of the 6th P.M., City of Fort Collins, Larimer County, Colorado. Total Site Area = 8 acres +/- EXISTING CONDITIONS Rational "C" Factor = 0.20 for Offsite Irrigated Areas " = 0.25 for Offsite Steeper Non -irrigated Areas = 0.25 for Onsite Irrigated Areas = 0.30 for Onsite Steeper Non -irrigated Areas PROPOSED DEVELOPMENT FOR LOT 1 Rational "C" Factor = 0.225 for Lawns and Landscaped Areas " " to = 0.95 for Roofs, Decks, Patios, etc. ft to It = 0.95 for Streets, Drives, and Parking Lawns and Landscaped Areas = 29,413 sq. ft. Roofs, Decks, Patios, etc. = 4,400 sq. ft. Streets, Drives, and Parkin; = 13,800 sq. ft. Area of Site Consideration = 325' x 146.5' = 47,613 sq. ft. "Q" avg = (29,413 x 0.225) + (4,400 x 0.95) + (13,8000 x 0.95)/ 47,613 "Q" avg= 0.50 Refer to following calculations for runoff'quantity determination CULVERT SIZING 1. New culvert to be installed at cul de sac street from Shields Street. The culvert is considered to be at "Inlet Control". Based upon the runoff calculations the design flows at this point are: Q2=6 cfs; and Q100=20 cfs; therefore - Using the Design Nomograph for Circular Pipe at Inlet Control: @ HW/D = 1.0 and Q = 6 cfs an 18" dia. pipe will be sufficient @ HW/D = 1.5 and Q = 20 cfs a 24" dia. pipe will be sufficient USE a 15" dia. pipe due to site constraints EROSION CONTROL The primary area of concern is the newly graded area adjacent to Laurie Drive at the inlet and outlet of the 15" culvert. We recommend these areas be seeded with pasture grasses. This may require some type of "drop structures" along its course and inlet and outlet protection at the proposed culvert under the cul de sac street. Additional protection at the inlet and outlet ends of the culvert at Shields Street should also be L4 provided. The City's Standard Erosion treatments for wind and storm -runoff should also be incorporated during the course of construction. • r V�ICI�N�IT�Y ..... AP EXHIIII "A" • 0 r0 � •� I: ��.I >I `( I _ `� vim• I 505 "sobs—osoc<r— .�-- u 0g� • I� �L S 5077. 5050 \ is • /�\ ` .. l �2'—�i�� c^ �� ^ �`�` \� l_ _III I \ I, .� \lI I� �1`•. h I' �1 'o a �5 06 c�,i�--III ��:�.°� •_ ,\�� __ —r 5i \I `1J 11 I •I'i''1�:'�1 �•�1�— 110 57 VICINITY MAP EXHIBIT "A" • �EXHiI�_:'IT "B" FOUNDATION ENGINEERING Calculated By: DRM STORM DRAINAGE INVESTIGATION # 1180-01-01-02 Client : Dr. Musslewhite Date : Dec. 29, 1989 RATIONAL METHOD PROCEDURE Project: LAURIE SUBDIVISION Checked By: KWP Design Storm: 2 YEAR Existing Conditions Location Point Area Runoff Coeff. Freq. Factor AxCxCf Flow Time Flow Time Rain Intens. Runoff Comments Description Designation (acres) C. 'Cf" Tchan(min.)Tc (min.) "I"(in./hr.)"O"(c.f.s.) Offsite Area 'A" Pt. A 10.5 0.2 1 2.10 15 2.1 4.41 Onsite Area 1 Pt. A+1 2 0.25 1 0.50 20 1.85 0.93 Pt. A+1 12.5 0.2 1 2.50 20 1.85 4.63 Flow at west side of Shields flowing to south Offsite Area "B' Pt. B 2.5 0.25 1 0.63 10 2.5 1.56 Onsite Area 3 Pt. 8+3 1 0.3 1 0.30 10 2.5 0.75 Pt. B+3 3.5 0.26 1 0.91 10 2.5 2.28 Flow at "minor" ravine at north central area Offsite Area "C' Pt. C 4.5 0.25 1 1.13 10 2.5 2.81 Onsite Area 4 Pt. C+4 1 0.3 1 0.30 10 2.5 0.75 Pt. C+4 5.5 0.26 1 1.43 10 2.5 3.58 Flow from north and west- add 30 c.f.s. irrig 33.60 Total with irrigation flow Onsite Area 6 Pt. 6 1 0.3 1 0.30 10 2.5 0.75 Total at Ravine Pt. B+C+6 10 0.26 1 2.60 15 2.1 5.46 Flow exiting site - add 30 c.f.s. irrig. 35.50 Total with irrigation flow Onsite Area 2 Pt. 2 1 0.3 1 0.30 10 2.5 0.75 Flow to south offsite overland Onsite Area 5 Pt. 5 1 0.3 1 0.30 10 2.5 0.75 Flow to south offsite to 'major' ravine Calculated By : DRM STORM DRAINAGE INVESTIGATION # 1180-01-01-02 Client : Dr. Musslewhite Date : Dec. 29, 1989 RATIONAL METHOD PROCEDURE Project: LAURIE SUBDIVISION Checked By: KWP Design Storm:100 YEAR - Existing Conditions Location Point Area Runoff Coeff. Freq. Factor AxCxCf Flow Time Flow Time Rain Intens. Runoff Comments Description Designation (acres) C. "Cf' Tchan(min.) Tc (min.) "I'(in./hr.)"O"(c.f.s.) Offsite Area "A' Pt. A 10.5 0.2 1.25 2.63 15 6 15.75 Onsite Area 1 Pt. A+1 2 0.25 1.25 0.63 20 5.15 3.22 Pt. A+1 12.5 0.2 1.25 3.13 20 5.15 16.09 Flow at west side of Shields flowing to south Offsite Area "B" Pt. B 2.5 0.25 1.25 0.78 10 7 5.47 Onsite Area 3 Pt. 13+3 1 0.3 1.25 0.38 10 7 2.63 Pt. B+3 3.5 0.26 1.25 1.14 10 7 7.96 Flow at 'minor" ravine at north central area Offsite Area "C' Pt. C 4.5 0.25 1.25 1.41 10 7 9.84 Onsite Area 4 Pt. C+4 1 0.3 1.25 0.38 10 7 2.63 Pt. C+4 5.5 0.26 1.25 1.79 10 7 12.51 Flow from north and west- add 30 c.f.s. irrig 42.50 Total with Irrigation flow Onsite Area 6 Pt. 6 1 0.3 1.25 0.38 10 7 2.63 Total at Ravine Pt. B+C+6 10 0.26 1.25 3.25 15 6 19.50 Flow exiting site - add 30 c.f.s. irrig. 49.50 Total with irrigation flow Onsite Area 2 Pt. 2 1 0.3 1.25 0.38 10 7 2.63 Flow to south offsite overland Onsite Area 5 Pt. 5 1 0.3 1.25 0.38 10 7 2.63 Flow to south offsite to "major" ravine • • Page 1 FOUNDATION ENGINEERING Calculated By: DRM STORM DRAINAGE INVESTIGATION # 1180-01-01-02 Client : Dr. Musslewhite Date : Dec. 29, 1989 RATIONAL METHOD PROCEDURE Project: SHIELDS STREET PROPERTY Checked By: KWP Design Storm: 2 YEAR Developed Conditions Location Point Area Runoff Coeff. Freq. Factor AxCxCf Flow Time Flow Time Rain Intens. Runoff Comments Description Designation (acres) C. V. Tchan(min.)Tc (min.) "I"(In./hr.)"Q"(c.f.s.) Offsite Area 'A" Pt. A 10.5 0.2 1 2.10 15 2.1 4.41 Onsite Area 1 Pt. A+1 2 0.5 1 1.00 20 1.85 1.85 Pt. A+1 12.5 0.25 1 3.13 20 1.85 5.78 Flow at west side of Shields flowing to south 0=6 cfs for Culvert sizing Offsite Area "B" Pt. B 2.5 0.25 1 0.63 10 2.5 1.56 Onsite Area 3 Pt. 13+3 1 0.3 1 0.30 10 2.5 0.75 Pt. B+3 3.5 0.26 1 0.91 1 0 2.5 2.28 Flow at "minor" ravine at north central area Offsite Area "C" Pt. C 4.5 0.25 1 1.13 10 2.5 2.81 Onsite Area 4 Pt. C+4 1 0.3 1 0.30 10 2.5 0.75 Pt. C+4 5.5 0.26 1 1.43 10 2.5 3.58 Flow from north and west- add 30 c.f.s. Irrig 33.60 Total with irrigation flow Onsite Area 6 Pt. 6 1 0.3 1 0.30 10 2.5 0.75 Total at Ravine Pt. B+C+6 10 0.26 1 2.60 15 2.1 5.46 Flow exiting site - add 30 c.f.s. Irrig. 35.50 Total with Irrigation flow Onsite Area 2 Pt. 2 1 0.3 1 0.30 10 2.5 0.75 Flow to south offsite overland Onsite Area 5 Pt. 5 1 0.3 1 0.30 10 2.5 0.75 Flow to south offsite to "major" ravine Calculated By: DRM STORM DRAINAGE INVESTIGATION # 1180-01-01-02 Client : Dr. Musslewhite Date : Dec. 29, 1989 RATIONAL METHOD PROCEDURE Project: SHIELDS STREET PROPERTY Checked By: KWP Design Storm: 100 YR.-Developed Conditions Location Point Area Runoff Coeff. Freq. Factor AxCxCf Flow Time Flow Time Rain Intens. Runoff _ Comments Description Designation (acres) C. "Cf. Tchan(min.) Tc (min.) "I"(in./hr.)'Q'(c.f.s.) Offsite Area "A" Pt. A 10.5 0.2 1.25 2.63 15 6 15.75 Onsite Area 1 Pt. A+1 2 0.5 1.25 1.25 20 5.15 6.44 Pt. A+1 12.5 0.25 1.25 3.91 20 5.15 20.12 Flow at west side of Shields flowing to south Q=20 cfs for Culvert sizing Offsite Area "B" Pt. B 2.5 0.25 1.25 0.78 10 7 5.47 Onsite Area 3 Pt. B+3 1 0.3 1.25 0.38 10 7 2.63 Pt. B+3 3.5 0.26 1.25 1.14 10 7 7.96 Flow at "minor" ravine at north central area Offsite Area "C" Pt. C 4.5 0.25 1.25 1.41 10 7 9.84 Onsite Area 4 Pt. C+4 1 0.3 1.25 0.38 10 7 2.63 Pt. C+4 5.5 0.26 1.25 1.79 10 7 12.51 Flow from north and west- add 30 c.f.s. irrig 42.50 Total with irrigation flow Onsite Area 6 Pt. 6 1 0.3 1.25 0.38 10 7 2.63 Total at Ravine Pt. B+C+6 10 0.26 1.25 3.25 15 6 19.50 Flow exiting site - add 30 c.f.s. irrig. 49.50 Total with irrigation flow Onsite Area 2 Pt. 2 1 0.3 1.25 0.38 10 7 2.63 Flow to south offsite overland Onsite Area 5 Pt. 5 1 0.3 1.25 0.38 10 7 2.63 Flow to south offsite to "major" ravine • Page 2 DRAINAGE PLAN EXMM.? M = IT ONI