HomeMy WebLinkAboutJEROME STREET STATION - PDP210009 - SUBMITTAL DOCUMENTS - ROUND 1 - GEOTECHNICAL (SOILS) REPORTPRELIMINARY GEOTECHNICAL SUBSURFACE EXPLORATION REPORT
BLOCK 1 – OLD TOWN NORTH
FORT COLLINS, COLORADO
SOILOGIC # 17-1079
April 10, 2017
Soilogic, Inc.
3050 67th Avenue, Suite 200 Greeley, CO 80634 (970) 535-6144
P.O. Box 1121 Hayden, CO 81639 (970) 276-2087
April 10, 2017
Brinkman Partners
3528 Precision Drive, Suite 100
Fort Collins, Colorado 80528
Attn: Ms. Tina Hippeli
Re: Preliminary Geotechnical Subsurface Exploration Report
Block 1 – Old Town North
Fort Collins, Colorado
Soilogic Project # 17-1079
Ms. Hippeli:
Soilogic, Inc. (Soilogic) personnel have completed the preliminary geotechnical
subsurface exploration you requested for an approximate 4-acre parcel of land described
as Block 1 of the Old Town North subdivision in Fort Collins, Colorado The results of
our preliminary exploration are included with this report.
The subsurface materials encountered in the completed test borings consisted of a thin
mantle of vegetation and topsoil underlain by light to dark brown silty lean clay/silty
sand. The lean clay/silty sand varied from medium stiff to hard in terms of consistency
or from loose to medium dense in terms of relative density, exhibited low swell potential
at in-situ moisture and density conditions and extended to depths ranging from
approximately 6 to 7 feet below ground surface, where it transitioned to relatively clean,
brown sand and gravel. The sand and gravel varied from medium dense to very dense in
terms of relative density, would be expected to be non-expansive based on the material’s
physical properties and engineering characteristics and extended to the bottom of boring
B-4 at a depth of approximately 15 feet below ground surface or to depths ranging from
approximately 17 to 22 feet below grade at the location of borings B-1 through B-3,
where it was underlain by blue-grey siltstone/sandstone bedrock. The siltstone/sandstone
was very hard in terms of relative hardness, would be expected to be non-expansive or
possess low swell potential at in-situ conditions based on the materials physical
properties and engineering characteristics and extended to the bottom of borings B-1
through B-3 at a depth of approximately 30 feet below present site grades.
Preliminary Geotechnical Subsurface Exploration Report
Block 1 – Old Town North
Fort Collins, Colorado
Soilogic # 17-1079
2
Groundwater was encountered in each of the completed site borings at depths ranging
from approximately 7½ to 8 feet below ground surface at the time of drilling. When
checked about 24 hours after completion of drilling, groundwater was measured at depths
of approximately 6½, 7, 7 and 6½ feet below ground surface at the location of borings B-
1 through B-4 respectively. Groundwater level information is indicated in the upper
right-hand corner of the attached boring logs.
Based on the subsurface conditions encountered in the completed site borings, results of
laboratory testing and type of construction proposed, we expect lightly-loaded residential
structures could be constructed with conventional footing foundations and floor slabs
bearing on the site lean clay/silty sand or sand and gravel with no to low swell potential.
Care will be needed to ensure all individual structure footing foundations bear on like
materials. Extending garage and any other upper-level footing foundations to bear at
slightly greater depth may be required in some areas in order to develop consistent
foundation bearing.
Care will be needed to maintain adequate separation distances between footing
foundations and the observed level of groundwater. Typically we recommend foundation
excavations be established a minimum of three (3) feet above the observed groundwater
level. This will require that foundation excavations extend no deeper than approximately
3½ to 4 feet below ground surface at the boring locations. As a result, raised basement or
crawl space construction could be considered for this project site. Raising site grades
through fill placement and/or lowering site groundwater levels with an underdrain could
also be considered to facilitate full basement construction. An underdrain system would
require a suitable outfall.
The silty lean clay and silty sand soils encountered near surface in the completed site borings
would be particularly susceptible to disturbance from construction activities when elevated in
moisture content. In addition, the lean clay/silty sand would be expected to be soft/loose and
elevated in moisture near current groundwater levels. Care should be taken to avoid
disturbing the site soils and the need for corrective action. Cuts extended close to current
groundwater levels may require construction of a working platform with filter fabric and
screened rock to reduce disturbance to the subgrade soils Disturbed soils should be
removed and replaced or reworked in place prior to placement of any fill or overlying
Preliminary Geotechnical Subsurface Exploration Report
Block 1 – Old Town North
Fort Collins, Colorado
Soilogic # 17-1079
2
improvements. In addition, if soft/loose lean clay/silty sand are observed at proposed
foundation bearing elevation at the time of construction of the proposed site structures,
some overexcavation/backfill procedures or other approved stabilization measures may be
required to redevelop suitable strength foundation bearing prior to concrete placement.
Based on the results of completed laboratory testing, the site lean clay, silty sand and
underlying sand and gravel appear suitable for use as low volume change (LVC) fill to
develop the site. If city streets will be constructed as part of this project, a final pavement
exploration will be required for the development after streets have been graded to
approximate finish subgrade elevation and water and sewer utilities installed in
accordance with the Larimer County Urban Area Street Standards (LCUASS). Other
preliminary opinions and recommendations concerning design criteria and construction
details for the proposed site improvements are included with this report. Preliminary
pavement section design estimates are also included.
We appreciate the opportunity to be of service to you on this project. If you have any
questions concerning the enclosed information or if we can be of further service to you in
any way, please do not hesitate to contact us.
Very Truly Yours,
Soilogic, Inc. Reviewed by:
Wolf von Carlowitz, P.E. Darrel DiCarlo, P.E.
Principal Engineer Senior Project Engineer
36746 44271
PRELIMINARY GEOTECHNICAL SUBSURFACE EXPLORATION REPORT
BLOCK 1 – OLD TOWN NORTH
FORT COLLINS, COLORADO
SOILOGIC # 17-1079
April 10, 2017
INTRODUCTION
This report contains the results of the preliminary geotechnical subsurface exploration
completed for an approximate 4-acre parcel of land described as Block 1 of the Old Town
North subdivision in Fort Collins, Colorado. The purpose of our exploration was to
describe the subsurface conditions encountered in the completed site borings and develop
preliminary recommendations concerning design and construction of office and residence
foundations and support of floor slabs and site pavements. Recommendations concerning
the installation of site utilities and preliminary pavement section design estimates are also
included. The conclusions and recommendations outlined in this report are based on the
results of the completed field and laboratory testing and our experience with subsurface
conditions in this area.
PROPOSED CONSTRUCTION
The proposed development includes a total of approximately 4 acres that may be
developed with office buildings and residential structures. We expect the office
structures will be lightly-loaded single-story steel structures constructed as slab-on-grade.
The residences are expected to be one or two-story wood frame structures constructed
over garden-level or raised basements due to the presence of comparatively shallow
groundwater. Foundations loads for the structures are expected to be light, with
continuous wall loads less than 3.5 kips per lineal foot and individual column loads less
than 75 kips. Floor loads are expected to be light, less than 100 psf. Infrastructure
improvements for the development will include utility installation and roadway
construction. We expect the site roadways will be used by low volumes of passenger
vehicles and light trucks, with occasional heavy truck traffic. Small grade changes are
anticipated to develop finish site grades.
Preliminary Geotechnical Subsurface Exploration Report
Block 1 – Old Town North
Fort Collins, Colorado
Soilogic # 17-1079
2
SITE DESCRIPTION
The development site includes a total of approximately 4 acres described as Block 1 of
the Old Town North subdivision in Fort Collins, Colorado. At the time of our site
exploration, a large soil stockpile was observed to be generally centrally located on the
project site. Outside of the soil stockpile, the site contained a moderate growth of grass
and weed vegetation including a few small diameter deciduous trees and was relatively
level, with the maximum difference in ground surface elevation across the property
estimated to be less than 5 feet. Evidence of prior building construction was not observed
in the area of proposed development at the time of drilling.
SITE EXPLORATION
Field Exploration
To develop subsurface information across the development parcel, a total of four (4) soil
borings were extended to depths ranging from approximately 15 to 30 feet below present
site grades. The proposed boring locations were established in the field by Soilogic
personnel based on a proposed boring layout diagram provided by the client and by
pacing and estimating angels and distances from identifiable site references. A diagram
indicating the approximate boring locations is included with this report. The boring
locations outlined on the attached diagram should be considered accurate only to the
degree implied by the methods used to make the field measurements. Graphic logs of
each of the auger borings are also included.
The test holes were advanced using 4-inch diameter continuous-flight auger powered by a
truck-mounted CME-45 drill rig. Samples of the subsurface materials were obtained at
regular intervals using California barrel sampling procedures in general accordance with
ASTM specification D-1586. As part of the D-1586 sampling procedure, the standard
sampling barrel is driven into the substrata using a 140-pound hammer falling a distance
of 30 inches. The number of blows required to advance the sampler a distance of 12
inches is recorded and helpful in estimating the consistency, relative density and/or
hardness of the soils and/or bedrock encountered. In the California barrel sampling
procedure, lesser disturbed samples are obtained in removable brass liners. Samples of
Preliminary Geotechnical Subsurface Exploration Report
Block 1 – Old Town North
Fort Collins, Colorado
Soilogic # 17-1079
3
the subsurface materials obtained in the field were sealed and returned to the laboratory
for further evaluation, classification and testing. As part of our field services, slotted
PVC piezometers were installed in the open boreholes prior to backfilling to allow for
longer-term observation of site groundwater levels.
Laboratory Testing
The samples collected were tested in the laboratory to measure natural moisture content
and visually and/or manually classified in accordance with the Unified Soil Classification
System (USCS). The USCS group symbols are indicated on the attached boring logs.
An outline of the USCS classification system is included with this report. Classification
of bedrock was completed through visual and tactual observation of disturbed samples.
Other bedrock types could be revealed through petrographic analysis.
As part of the laboratory testing, a calibrated hand penetrometer (CHP) was used to
estimate the unconfined compressive strength of essentially-cohesive specimens. The
CHP also provides a more reliable estimate of soil/bedrock consistency than tactual
observation alone. Dry density, Atterberg limits, -200 wash and swell/consolidation tests
were completed on selected samples to help establish specific soil/bedrock
characteristics. Atterberg limits tests are used to determine soil/bedrock plasticity. The
percent passing the #200 size sieve (-200 wash) test is used to determine the percentage
of fine-grained materials (clay and silt) in a sample. Swell/consolidation tests are
performed to evaluate soil/bedrock volume change potential with variation in moisture
content. The results of the completed laboratory tests are outlined on the attached boring
logs and swell/consolidation test summaries. Water Soluble Sulfates (WSS) tests were
also completed on two (2) selected soil samples to evaluate corrosive soil characteristics
with respect to buried concrete and results discussed subsequently in this report.
SUBSURFACE CONDITIONS
The subsurface materials encountered in the completed test borings consisted of a thin
mantle of vegetation and topsoil underlain by light to dark brown silty lean clay/silty
sand. The apparently natural lean clay/silty sand varied from medium stiff to hard in
terms of consistency or from loose to medium dense in terms of relative density,
Preliminary Geotechnical Subsurface Exploration Report
Block 1 – Old Town North
Fort Collins, Colorado
Soilogic # 17-1079
4
exhibited low swell potential at in-situ moisture and density conditions and extended to
depths ranging from approximately 6 to 7 feet below ground surface, where it
transitioned to relatively clean, brown sand and gravel. The sand and gravel varied from
medium dense to very dense in terms of relative density, would be expected to be non-
expansive based on the material’s physical properties and engineering characteristics and
extended to the bottom of boring B-4 at a depth of approximately 15 feet below ground
surface or to depths ranging from approximately 17 to 22 feet below grade at the
locations of borings B-1 through B-3, where it was underlain by grey/blue
siltstone/sandstone bedrock. The siltstone/sandstone was very hard in terms of relative
hardness, would be expected to be non-expansive or possess low swell potential at in-situ
conditions based on the materials physical properties and engineering characteristics and
extended to the bottom of borings B-1 through B-3 at a depth of approximately 30 feet
below present site grades.
The stratigraphy indicated on the included boring logs represents the approximate
location of changes in soil and bedrock types. Actual changes may be more gradual than
those indicated.
Groundwater was encountered in each of the completed site borings at depths ranging
from approximately 7½ to 8 feet below ground surface at the time of drilling. When
checked about 24 hours after completion of drilling, groundwater was measured at depths
of approximately 6½, 7, 7 and 6½ feet below ground surface at the location of borings B-
1 through B-4 respectively. Groundwater level information is indicated in the upper
right-hand corner of the attached boring logs.
Groundwater levels will vary seasonally and over time based on weather conditions, site
development, irrigation practices and other hydrologic conditions. Perched and/or
trapped groundwater conditions may also be encountered at times throughout the year.
Perched water is commonly encountered in soils overlying less permeable soil layers
and/or bedrock. Trapped water is typically encountered within more permeable zones of
layered soil and bedrock systems. The location and amount of perched/trapped water can
also vary over time.
Preliminary Geotechnical Subsurface Exploration Report
Block 1 – Old Town North
Fort Collins, Colorado
Soilogic # 17-1079
5
ANALYSIS AND RECOMMENDATIONS
General
Groundwater was measured in the installed site piezometers at depths ranging from
approximately 6½ to 7 feet below ground surface when checked about 24 hours after the
completion of drilling. Typically, we recommend foundation bearing be established a
minimum of three (3) feet above the level of water observed in order to account for some
seasonal fluctuation in the level of water and reduce the potential for water infiltration
into basement areas of the proposed residences. This will result in maximum foundation
excavation depths in the range of about 3½ to 4 feet below grade. As such, raised
basement or crawl space construction could be considered for this site. Closer evaluation
of the depth to groundwater should be completed during site-specific explorations, to be
performed after site development in order to better define the depth to groundwater at the
individual structure locations. Raising site grades through fill placement or lowering site
groundwater levels with an underdrain system could be considered to facilitate full
basement construction. An underdrain system would require a suitable outfall.
Care will be needed to ensure all individual structure footing foundations bear on like
materials. Extending garage and any other upper-level footing foundations to bear at
slightly greater depth may be required in some areas in order to develop consistent
foundation bearing.
The silty lean clay and silty sand soils encountered near surface in the completed site borings
would be particularly susceptible to disturbance from construction activities when elevated in
moisture content. In addition, the lean clay/silty sand would be expected to be soft/loose and
elevated in moisture near current groundwater levels. Care should be taken to avoid
disturbing the site soils and the need for corrective action. Cuts extended close to current
groundwater levels may require construction of a working platform with filter fabric and
screened rock to reduce disturbance to the subgrade soils Disturbed soils should be
removed and replaced or reworked in place prior to placement of any fill or overlying
improvements. In addition, if soft/loose lean clay/silty sand are observed at proposed
foundation bearing elevation at the time of construction of the proposed site structures,
Preliminary Geotechnical Subsurface Exploration Report
Block 1 – Old Town North
Fort Collins, Colorado
Soilogic # 17-1079
6
some overexcavation/backfill procedures or other approved stabilization measures may be
required to redevelop suitable strength foundation bearing prior to concrete placement.
Site Development
All existing vegetation and topsoil should be completely removed from any proposed fill
and exterior flatwork and pavement areas. We do not expect the stockpiled site soils
were placed as controlled and compacted fill and tested at the time of placement and
compaction for moisture and density, such that all existing stockpiled fill should also be
completely removed at this time. After stripping and completing all fill removal and
any cuts and prior to placement of any new fill or flatwork concrete, we recommend the
exposed subgrade soils be scarified to a depth of 9 inches, adjusted in moisture content
and compacted to at least 95% of the materials standard Proctor maximum dry density.
The moisture content of the scarified soils should be adjusted to be within the range of
±2% of standard Proctor optimum moisture content at the time of compaction.
Fill soils required to develop the site should consist of approved, low-volume-change
(LVC) soils free from organic matter, debris and other objectionable materials. Based on
results of the completed laboratory testing, it is our opinion the site lean clay, silty sand
and underlying sand and gravel could be used as fill to develop the site provided the
proper moisture content is developed in those materials at the time of placement and
compaction. Further evaluation of the stockpiled site soils would be required to
determine if these materials would be suitable for use as fill to develop the site. Suitable
fill soils should be placed in loose lifts not to exceed 9 inches thick, adjusted in moisture
content and compacted as recommended for the scarified soils above.
Care should be taken to avoid disturbing the reconditioned subgrade soils and placed fill
soils. Soils which are allowed to dry out or become wet and softened or disturbed by the
construction activities should be removed and replaced or reworked in place prior to
placement of any overlying improvements.
Preliminary Geotechnical Subsurface Exploration Report
Block 1 – Old Town North
Fort Collins, Colorado
Soilogic # 17-1079
7
Footing Foundations
Based on the materials encountered in the completed site borings and the results of
laboratory testing, we expect a majority, if not all of the relatively lightly-loaded site
structures could be supported on conventional footing foundations bearing on the natural,
undisturbed site lean clay, silty sand and/or sand and gravel with low swell potential
and/or suitable fill soils placed and compacted as outlined above a minimum of three (3)
feet above observed groundwater. The foundations for the individual structures should
bear on like materials. Drilled pier foundations could also be considered for support of
more heavily loaded site structures, but will most likely require casing of the drilled
shafts to facilitate construction as well as specialized rock augers/core barrels to fully
penetrate the very hard bedrock encountered.
For design of footing foundations bearing on the natural site lean clay, silty sand and/or
properly placed and compacted fill, maximum net allowable soil bearing pressures in the
range of 1,000 to 2,000 psf appear usable. Overexcavation and replacement of the
proposed foundation bearing soils with select granular import fill could also be
considered to develop higher maximum net allowable soil bearing pressures (in the range
of 2,000 to 3,000 psf). Individual site-specific subsurface explorations should be
completed for each proposed site structure after overlot grading of the site has been
completed to help better define subsurface soil/bedrock and groundwater conditions.
Floor Slabs
Based on the results of the completed laboratory testing, we expect a majority of lightly-
loaded floor slabs could be supported on reconditioned natural site soils and/or properly
placed and compacted fill. If moderately expansive clay soils or existing undocumented
fill are identified near surface, some overexcavation/backfill procedures would be
required beneath garage and any other at-grade floor slabs prior to concrete placement.
Care should be taken to avoid disturbing floor slab subgrades prior to concrete placement.
Subgrade soils expected to receive flatwork concrete should be evaluated closely prior to
surfacing. If areas of disturbed, wet and softened, or dry subgrade soils develop during
Preliminary Geotechnical Subsurface Exploration Report
Block 1 – Old Town North
Fort Collins, Colorado
Soilogic # 17-1079
8
construction, those materials should be removed and replaced or reworked in place prior
to placement of the overlying improvements.
Raised Basement/Crawl Space Construction
We recommend perimeter drain systems be installed around all below-grade and crawl
space areas to help reduce the potential for development of hydrostatic pressures behind
the foundation walls and water infiltration into the basement/crawl space areas. A
perimeter drain system should consist of a 4-inch diameter perforated drain pipe
surrounded by a minimum of six (6) inches of free-draining gravel. A filter fabric should
be considered around the free-draining gravel or perforated pipe to reduce the potential
for an influx of fine-grained soils into the system. The drain pipe should be placed at
approximate foundation bearing level around the exterior perimeter of the below-grade
areas and interior perimeter of crawl space areas and run to a sump pit and pump system,
or project underdrain system with a minimum slope of ⅛-inch per foot to facilitate
efficient water removal.
Backfill placed adjacent to the foundation walls should consist of LVC potential and
relatively impervious soils which are free from organic matter, debris and other
objectionable materials. The site lean clay and silty sand could be used as fill in these
areas. Foundation wall backfill soils should be placed in loose lifts not to exceed 9
inches thick, adjusted in moisture and compacted as previously outlined in the “Site
Development” section of this report.
Excessive lateral stress can be imposed on below-grade walls when using heavier
mechanical compaction equipment. We recommend compaction of unbalanced basement
wall backfill be completed using light mechanical or hand compaction equipment.
Utility Installation
Bedding around utility pipelines should be placed in accordance with recommendations
from the pipeline designer. Backfill soils placed above pipelines should consist of
approved materials which are free from organic matter, debris and other objectionable
materials. The on-site lean clay, silty sand and underlying sand and gravel could be used
Preliminary Geotechnical Subsurface Exploration Report
Block 1 – Old Town North
Fort Collins, Colorado
Soilogic # 17-1079
9
as pipeline backfill. Pipeline backfill should be placed in maximum 9-inch loose lifts,
adjusted in moisture and compacted as previously outlined in the “Site Development”
section of this report. Wet soils encountered with depth would need to be dried out prior
to placement as utility backfill.
The site silty sand and cleaner sand and gravel soils encountered with depth in the
completed site borings would be particularly susceptible to sloughing and caving during
excavation. Care will be needed to ensure utilities are not placed on or above disturbed
or sloughed materials. Utility excavations will likely expose the overburden lean clay,
silty sand and cleaner sand and gravel with depth. Care will also be needed to develop
stable side slopes in pipeline trenches excavated through soft lean clay and less cohesive
silty sand and gravel soils. As such, we expect temporary shoring, bracing, or cutting of
shallow slopes may be necessary in deeper excavations. Excavations should be sloped or
shored in the interest of safety following local and federal regulations, including current
OSHA excavation and trench safety standards. As a safety measure, it is recommended
that vehicles and soil stockpiles be kept to a minimum lateral distance from the crest of
the slope equal to no less than the slope height.
Cuts below groundwater elevation will require dewatering to facilitate proper
construction. We expect a majority of the dewatering procedures could be completed
through open pumping procedures in sumps fed from ditches or sloped trench
excavations. Deeper utility excavations may require well point systems for dewatering in
order to facilitate proper construction.
Site Roadways
We expect the pavement subgrades will consist of the site lean clay and silty sand with
low swell potential. If City of Fort Collins streets with be constructed as part of this
project, a final subgrade evaluation and pavement section design report will be required
once roadways are developed to approximate finish grade and water and sewer utilities
installed in accordance with the Larimer County Urban Area Street Standards
(LCUASS). For preliminary design estimates, a pavement section consisting of 4 inches
of asphaltic concrete overlying 6 inches of aggregate base course could be used for local
residential streets and light duty private pavement areas. A pavement section consisting
Preliminary Geotechnical Subsurface Exploration Report
Block 1 – Old Town North
Fort Collins, Colorado
Soilogic # 17-1079
10
of 5 inches of asphaltic concrete overlying 8 inches of aggregate base course could be
used for preliminary estimates for collector roadways and heavy-duty private pavement
areas.
Drainage
Positive drainage is imperative for satisfactory long-term performance of the proposed
site structures and associated site improvements. We recommend positive drainage be
developed away from all site structures and pavement areas to reduce the potential for
wetting of the subgrade and bearing materials. Water which is allowed to pond adjacent
to the site improvements can result in unacceptable performance of those improvements
over time.
LIMITATIONS
This report was prepared based upon the data obtained from the completed site
exploration, laboratory testing, engineering analysis and any other information discussed.
The completed borings provide an indication of subsurface conditions at the boring
locations only. Variations in subsurface conditions can occur in relatively short distances
away from the borings. This report does not reflect any variations which may occur
across the site or away from the borings. If variations in the subsurface conditions
anticipated become evident, the geotechnical engineer should be notified immediately so
that further evaluation and supplemental recommendations can be provided.
The scope of services for this project does not include either specifically or by
implication any biological or environmental assessment of the site or identification or
prevention of pollutants or hazardous materials or conditions. Other studies should be
completed if concerns over the potential of such contamination or pollution exist.
The geotechnical engineer should be retained to review the plans and specifications so
that comments can be made regarding the interpretation and implementation of our
geotechnical recommendations in the design and specifications. The geotechnical
engineer should also be retained to provide testing and observation services during
construction to help determine that the design requirements are fulfilled.
Preliminary Geotechnical Subsurface Exploration Report
Block 1 – Old Town North
Fort Collins, Colorado
Soilogic # 17-1079
11
This report has been prepared for the exclusive use of our client for specific application
to the project discussed and has been prepared in accordance with the generally accepted
standard of care for the profession. No warranties express or implied, are made. The
conclusions and recommendations contained in this report should not be considered valid
in the event that any changes in the nature, design or location of the project as outlined in
this report are planned, unless those changes are reviewed and the conclusions of this
report modified and verified in writing by the geotechnical engineer.
LOG OF BORING B-1
1/1 CME 45
4" CFA
Automatic
CP/ZG
Estimated Swell % Passing
SOIL DESCRIPTION Depth "N"MC DD qu % Swell @ Pressure # 200 Sieve
(ft)(%)(pcf)(psf)500 psf (psf)LL PI (%)
6" VEGETATION AND TOPSOIL -
1
-
2
CL-SM SILTY LEAN CLAY/SILTY SAND -
light to dark brown 3
very stiff/medium dense -
4
-
5 CS 23 7.2 -N/A -----
-
6
-
7
-
8
-
9
SP-GP SAND AND GRAVEL -
brown 10 CS 19 4.1 -N/A --NL NP 5.4%
medium dense to dense -
11
-
12
-
13
-
14
-
15 CS 50/10 6.0 -N/A -----
-
16
-
17
-
18
-
19
-
20 CS 50/4 17.9 -9000+-----
-
21
-
SILTSTONE/SANDSTONE 22
grey/blue -
very hard 23
-
24
-
25
-
26
-
27
-
28
-
29
-
BOTTOM OF BORING @ 30.0'30 CS 50/2 --- - - - - - USCSSamplerAtterberg Limits
Surface Elev.-Field Personnel:24 Hours After Drilling 6.5'
Finish Date 3/23/2017 Hammer Type:After Drilling 8'
Sheet Drilling Rig:Water Depth Information
Start Date 3/23/2017 Auger Type:During Drilling 8'
BLOCK 1 - OLD TOWN NORTH PRELIMINARY EXPLORATION
FORT COLLINS, COLORADO
Project # 17-1079
April 2017
LOG OF BORING B-2
1/1 CME 45
4" CFA
Automatic
CP/ZG
Estimated Swell % Passing
SOIL DESCRIPTION Depth "N"MC DD qu % Swell @ Pressure # 200 Sieve
(ft)(%)(pcf)(psf)500 psf (psf)LL PI (%)
6" VEGETATION AND TOPSOIL -
1
-
2
CL-SM SILTY LEAN CLAY/SILTY SAND -
light to dark brown 3
stiff -
4
-
5 CS 12 2.7 -N/A --NL NP 13.9%
-
6
-
7
-
8
-
9
-
SP-GP SAND AND GRAVEL 10 CS 29 5.0 -N/A -----
brown -
medium dense to very dense 11
-
12
-
13
-
14
-
15 CS 50/8 8.5 -N/A -----
-
16
-
17
-
18
-
19
-
20 CS 50/7 16.3 -N/A -----
-
21
-
22
-
23
-
SILTSTONE/SANDSTONE 24
grey/blue -
very hard 25
-
26
-
27
-
28
-
29
-
BOTTOM OF BORING @ 30.0'30 CS 50/2 --- - - - - -
Sheet Drilling Rig:Water Depth Information
BLOCK 1 - OLD TOWN NORTH PRELIMINARY EXPLORATION
FORT COLLINS, COLORADO
Project # 17-1079
April 2017
USCSSamplerAtterberg Limits
Start Date 3/23/2017 Auger Type:During Drilling 8'
Finish Date 3/23/2017 Hammer Type:After Drilling 8'
Surface Elev.-Field Personnel:24 Hours After Drilling 7'
LOG OF BORING B-3
1/1 CME 45
4" CFA
Automatic
CP/ZG
Estimated Swell % Passing
SOIL DESCRIPTION Depth "N"MC DD qu % Swell @ Pressure # 200 Sieve
(ft)(%)(pcf)(psf)500 psf (psf)LL PI (%)
6" VEGETATION AND TOPSOIL -
1
-
2
CL-SM SILTY LEAN CLAY/SILTY SAND -
light to dark brown 3
hard/medium dense -
4
-
5 CS 41 15.9 -N/A -----
-
6
-
7
-
8
-
SP-GP SAND AND GRAVEL 9
brown -
medium dense to dense 10 CS 20 8.0 -N/A --NL NP 6.8%
-
11
-
12
-
13
-
14
-
15 CS 50/8 7.8 -N/A -----
-
16
-
17
-
18
-
19
-
SILTSTONE/SANDSTONE 20 CS 50/3 21.0 -9000+-----
grey/blue -
very hard 21
-
22
-
23
-
24
-
25
-
26
-
27
-
28
-
29
-
BOTTOM OF BORING @ 30.0'30 CS 50/2 --- - - - - -
Sheet Drilling Rig:Water Depth Information
BLOCK 1 - OLD TOWN NORTH PRELIMINARY EXPLORATION
FORT COLLINS, COLORADO
Project # 17-1079
April 2017
USCSSamplerAtterberg Limits
Start Date 3/23/2017 Auger Type:During Drilling 7.5'
Finish Date 3/23/2017 Hammer Type:After Drilling 7.5'
Surface Elev.-Field Personnel:24 Hours After Drilling 7'
LOG OF BORING B-4
1/1 CME 45
4" CFA
Automatic
CP/ZG
Estimated Swell % Passing
SOIL DESCRIPTION Depth "N"MC DD qu % Swell @ Pressure # 200 Sieve
(ft)(%)(pcf)(psf)500 psf (psf)LL PI (%)
6" VEGETATION AND TOPSOIL -
1
-
2
CL-SM SILTY LEAN CLAY/SILTY SAND -
light to dark brown 3
medium stiff/loose -
4
-
5 CS 8 25.5 97.3 5000 0.2%600 ---
-
6
-
7
-
8
-
9
SP-GP SAND AND GRAVEL -
brown 10 CS 50/10 8.8 -N/A --NL NP 4.1%
medium dense to dense -
11
-
12
-
13
-
14
-
15 CS 25 9.2 -N/A -----
BOTTOM OF BORING @ 15.0'-
16
-
17
-
18
-
19
-
20
-
21
-
22
-
23
-
24
-
25
Sheet Drilling Rig:Water Depth Information
BLOCK 1 - OLD TOWN NORTH PRELIMINARY EXPLORATION
FORT COLLINS, COLORADO
Project # 17-1079
April 2017
USCSSamplerAtterberg Limits
Start Date 3/23/2017 Auger Type:During Drilling 8'
Finish Date 3/23/2017 Hammer Type:After Drilling 8'
Surface Elev.-Field Personnel:24 Hours After Drilling 6.5'
Liquid Limit -
Plasticity Index -
% Passing #200 -
Dry Density (pcf)97.3
500
Final Moisture 26.0%
% Swell @ 500 psf 0.2%
Swell Pressure (psf)600
Sample ID: B-4 @ 4
Sample Description: Dark Brown Sandy Lean Clay (CL)
Initial Moisture 25.5%
SWELL/CONSOLIDATION TEST SUMMARY
BLOCK 1 - OLD TOWN NORTH PRELIMINARY EXPLORATION
FORT COLLINS, COLORADO
Project # 17-1079
April 2017
-12
-10
-8
-6
-4
-2
0
2
4
6
8
10
12
10 100 1000 10000 100000
---------
Applied Load (psf)
UNIFIED SOIL CLASSIFICATION SYSTEM
Criteria for Assigning Group Symbols and Group Names Using Laboratory TestsA Soil Classification
Group
Symbol
Group NameB
Cu ! 4 and 1 " Cc " 3E GW Well graded gravelF Clean Gravels
Less than 5% finesC Cu < 4 and/or 1 > Cc > 3E GP Poorly graded gravelF
Fines classify as ML or MH GM Silty gravelF,G, H
Coarse Grained Soils
More than 50% retained
on No. 200 sieve
Gravels
More than 50% of coarse
fraction retained on
No. 4 sieve Gravels with Fines More
than 12% finesC Fines classify as CL or CH GC Clayey gravelF,G,H
Cu ! 6 and 1 " Cc " 3E SW Well graded sandI Clean Sands
Less than 5% finesD Cu < 6 and/or 1 > Cc > 3E SP Poorly graded sandI
Fines classify as ML or MH SM Silty sandG,H,I
Sands
50% or more of coarse
fraction passes
No. 4 sieve Sands with Fines
More than 12% finesD Fines classify as CL or CH SC Clayey sandG,H,I
PI > 7 and plots on or above “A” lineJ CL Lean clayK,L,M Silts and Clays
Liquid limit less than 50
Inorganic
PI < 4 or plots below “A” lineJ ML SiltK,L,M
Liquid limit - oven
dried
Organic clayK,L,M,N
Fine-Grained Soils
50% or more passes the
No. 200 sieve
Organic
Liquid limit - not
dried
< 0.75 OL
Organic siltK,L,M,O
Inorganic PI plots on or above “A” line CH Fat clayK,L,M
Silts and Clays
Liquid limit 50 or more PI plots below “A” line MH Elastic siltK,L,M
Liquid limit - oven dried Organic clayK,L,M,P Organic
Liquid limit - not dried
< 0.75 OH
Organic siltK,L,M,Q
Highly organic soils Primarily organic matter, dark in color, and organic odor PT Peat
A Based on the material passing the 3-in. (75-mm) sieve
B If field sample contained cobbles or boulders, or both, add “with cobbles
or boulders, or both” to group name.
C Gravels with 5 to 12% fines require dual symbols: GW-GM well graded
gravel with silt, GW-GC well graded gravel with clay, GP-GM poorly
graded gravel with silt, GP-GC poorly graded gravel with clay.
D Sands with 5 to 12% fines require dual symbols: SW-SM well graded
sand with silt, SW-SC well graded sand with clay, SP-SM poorly graded
sand with silt, SP-SC poorly graded sand with clay
E Cu = D60/D10 Cc =
F If soil contains ! 15% sand, add “with sand” to group name.
G If fines classify as CL-ML, use dual symbol GC-GM, or SC-SM.
HIf fines are organic, add “with organic fines” to group name.
I If soil contains ! 15% gravel, add “with gravel” to group name.
J If Atterberg limits plot in shaded area, soil is a CL-ML, silty clay.
K If soil contains 15 to 29% plus No. 200, add “with sand” or “with
gravel,” whichever is predominant.
L If soil contains ! 30% plus No. 200 predominantly sand, add
“sandy” to group name.
M If soil contains ! 30% plus No. 200, predominantly gravel, add
“gravelly” to group name.
N PI ! 4 and plots on or above “A” line.
O PI < 4 or plots below “A” line.
P PI plots on or above “A” line.
Q PI plots below “A” line.
GENERAL NOTES
DRILLING & SAMPLING SYMBOLS:
SS: Split Spoon - 1⅜" I.D., 2" O.D., unless otherwise noted HS: Hollow Stem Auger
ST: Thin-Walled Tube – 2.5" O.D., unless otherwise noted PA: Power Auger
RS: Ring Sampler - 2.42" I.D., 3" O.D., unless otherwise noted HA: Hand Auger
CS: California Barrel - 1.92" I.D., 2.5" O.D., unless otherwise noted RB: Rock Bit
BS: Bulk Sample or Auger Sample WB: Wash Boring or Mud Rotary
The number of blows required to advance a standard 2-inch O.D. split-spoon sampler (SS) the last 12 inches of the total 18-inch
penetration with a 140-pound hammer falling 30 inches is considered the “Standard Penetration” or “N-value”. For 2.5” O.D.
California Barrel samplers (CB) the penetration value is reported as the number of blows required to advance the sampler 12
inches using a 140-pound hammer falling 30 inches, reported as “blows per inch,” and is not considered equivalent to the
“Standard Penetration” or “N-value”.
WATER LEVEL MEASUREMENT SYMBOLS:
WL: Water Level WS: While Sampling
WCI: Wet Cave in WD: While Drilling
DCI: Dry Cave in BCR: Before Casing Removal
AB: After Boring ACR: After Casing Removal
Water levels indicated on the boring logs are the levels measured in the borings at the times indicated. Groundwater levels at other
times and other locations across the site could vary. In pervious soils, the indicated levels may reflect the location of groundwater.
In low permeability soils, the accurate determination of groundwater levels may not be possible with only short-term observations.
DESCRIPTIVE SOIL CLASSIFICATION: Soil classification is based on the Unified Classification System. Coarse Grained Soils
have more than 50% of their dry weight retained on a #200 sieve; their principal descriptors are: boulders, cobbles, gravel or sand.
Fine Grained Soils have less than 50% of their dry weight retained on a #200 sieve; they are principally described as clays if they
are plastic, and silts if they are slightly plastic or non-plastic. Major constituents may be added as modifiers and minor constituents
may be added according to the relative proportions based on grain size. In addition to gradation, coarse-grained soils are defined
on the basis of their in-place relative density and fine-grained soils on the basis of their consistency.
FINE-GRAINED SOILS COARSE-GRAINED SOILS BEDROCK
(CB)
Blows/Ft.
(SS)
Blows/Ft.
Consistency
(CB)
Blows/Ft.
(SS)
Blows/Ft.
Relative
Density
(CB)
Blows/Ft.
(SS)
Blows/Ft.
Consistency
< 3 0-2 Very Soft 0-5 < 3 Very Loose < 24 < 20 Weathered
3-5 3-4 Soft 6-14 4-9 Loose 24-35 20-29 Firm
6-10 5-8 Medium Stiff 15-46 10-29 Medium Dense 36-60 30-49 Medium Hard
11-18 9-15 Stiff 47-79 30-50 Dense 61-96 50-79 Hard
19-36 16-30 Very Stiff > 79 > 50 Very Dense > 96 > 79 Very Hard
> 36 > 30 Hard
RELATIVE PROPORTIONS OF SAND AND
GRAVEL
GRAIN SIZE TERMINOLOGY
Descriptive Terms of
Other Constituents
Percent of
Dry Weight
Major Component
of Sample
Particle Size
Trace < 15 Boulders Over 12 in. (300mm)
With 15 – 29 Cobbles 12 in. to 3 in. (300mm to 75 mm)
Modifier > 30 Gravel 3 in. to #4 sieve (75mm to 4.75 mm)
Sand
Silt or Clay
#4 to #200 sieve (4.75mm to 0.075mm)
Passing #200 Sieve (0.075mm)
RELATIVE PROPORTIONS OF FINES PLASTICITY DESCRIPTION
Descriptive Terms of
Other Constituents
Percent of
Dry Weight
Term Plasticity Index
Trace
With
Modifiers
< 5
5 – 12
> 12
Non-plastic
Low
Medium
High
0
1-10
11-30
30+