Loading...
HomeMy WebLinkAboutFORT COLLINS HOUSING AUTHORITY PUD EXPANSION - FINAL - 28-89D - CORRESPONDENCE - STAFF'S PROJECT COMMENTSCommety Planning and Environmentffiaervices Planning Department City of Fort Collins December 16, 1994 James K. Kline Fort Collins Housing Authority 1715 Mountain Avenue Fort Collins, CO 80521 Dear Jim: City staff has reviewed your submittal for the Fort Collins Housing Authority PUD Expansion - Final and offers the following comments: The site plan does not indicate that the Housing Authority is providing a bike rack. You are encouraged to provide a bike rack and indicate it's location on the site plan and landscape plan. 2. Please see the attached comments from the Building Inspection Department. 3. With the addition, the building exceeds 5,000 square feet. This requires that an automatic fire suppression system must be installed. 4. Any relocation of Public Service facilities will be at the customer's expense. 5. Prior to Development Agreement approval, a $300.00 payment will be required to sponsor three tree plantings off site. This is for mitigation of the removal of City trees since the City Parks and Recreation Department owns the property and leases it to the Housing Authority. 6. The two new trees to be planted off the south side of the addition are to be Burr Oak, rather than Green Ash, with 2" caliper. 7. Please show existing water mains and sanitary sewers adjacent to the site on the site plan 8. The requested variance to the storm drainage requirements will be reviewed during the final review of the utility plans. 281 North College Avenue • P.O. Box 580 • Fort Collins, CO 80522-0580 • (303) 221-6730 0 Please note the following deadlines for the January 23, 1995 Planning and Zoning Board meeting: Plan revisions are due January 4, 1995 (5 sets of plans and written documentation responding to the above comments). PMT's (one PMT of each plan sheet), colored renderings and 8 sets of prints are due on January 17, 1995. Should you have any questions regarding these comments, please contact me. Sincerely, �-- Robert E. Blanchard, AICP I Chief Planner cc: Kerrie Ashbeck, Civil Engineer 28-89D Fort Collins Housing Authority - Final suppression system is required in accordance with Section 3802, UBC as amended by the City of Fort Collins. Storage or use of hazardous materials must be in compliance with the Fire Code and Chapter 9 of the 1991 Uniform Building Code as adopted by the City of Fort Collins. A list of such materials with quantities and classifications should be submitted for review at the time of building permit application. Exterior walls, openings in exterior walls and projections from exterior walls (cornices, eave overhangs, etc.) shall be of fire resistive construction as required by Table 5A, Uniform Building Code. The site, shall be accessible to persons with disabilities in accordance with Uniform Building Code Section 3103 and UBC Appendix Section 3106. Provide designated and marked accessible routes between buildings and the public way and accessible parking and the buildings. Provide parking and signs per Appendix Section 3107. Construction drawings submitted with application for building permit require the seal and signature of an architect or engineer registered in the State of Colorado. A general contractor with a valid C-01 level City license must be responsible for the construction of the addition. Sharon Getz Building Inspection/221-6760