Loading...
HomeMy WebLinkAboutSYMBIOS LOGIC PUD - PRELIMINARY - 5-94E - CORRESPONDENCE - SUPPORTING DOCUMENTATIONr� U June 10, 1996 Steve Olt City of Fort Collins -Community Development 281 N. College Ave. Fort Collins, CO 80524 RE: Symbios Logic P.U.D. Dear Steve, design LANDSCAPE ARCHITECTURE URBAN DESIGN PLANNING BHA DESIGN, INC. 2000 VERMONT FT. COLLINS, CO 80525 TEL 303 223-7577 Per our earlier conversation, I am sending four copies of the Shadow Analysis and the Point- FAX 303 226-3855 by -Point lighting analysis (prepared by Merit Electric) for the Symbios Logic P.U.D. This is how we computed the shadows: 1. Based on 40 degrees north latitude, shadows falling on December 21 at 9:00am, noon, and 3:00pm, the area of the shadow will range from 45 degrees west of north to • 45 degrees east of north. The length of the shadow is computed at 3.4 time the height of the building. 2. The hypothetical 25-foot high wall at the north property line will throw a shadow 85 feet to the north (3.4 x 25'-0"). 3. The 45-foot-high, three story portions of the building throw shadows 153 feet northwest, north, and northeast of the building (3.4 x 45'-0"). 4. The 30-foot-high, two story portions of the building throw shadows 102 feet northwest, north, and northeast of the building (3.4 x 30'-0"). If you prefer, I can submit a 24 x 36 shadow analysis on June 17th along with the additional plans, renderings, and PMT's. Please give me a call if you need anything else. Thank You, r Roger B. Sherman, ASLA No Text