Loading...
HomeMy WebLinkAboutFOOTHILLS PARKWAY PUD - PRELIMINARY - 36-89 - REPORTS - RECOMMENDATION/REPORT W/ATTACHMENTS (2)ITEM NO. 6 MEETING DATE 6f! S k STAFF Ted %92-g a City of Fort Collins PLANNING AND ZONING BOARD STAFF REPORT PROJECT: Foothills Parkway P.U.D., Preliminary - #36-89 APPLICANT: Round the Corner Restaurants, Inc. c/o Edward G. Zdenek Architects 223 Linden Street, Suite 105 Fort Collins, CO. 80524 OWNER: Steele's Market 309 West Mountain Avenue Fort Collins, CO. 80521 PROJECT DESCRIPTION: This is a request for a Preliminary P.U.D. and subdivision plat for a 2,780 square foot auto tune-up and lubrication shop (Econo Lube), and a 770 square foot drive-in restaurant (Good Times). The site measures .99 acre and is located at the northwest corner of South College Avenue and Foothills Park- way, directly in front of the South Steele's Market. The parcel is zoned H-B, Highway Business. RECOMMENDATION: Approval With Conditions EXECUTIVE SUMMARY: The two buildings have been evaluated against the criteria of the Auto Related and Roadside Commercial point chart. The score of 63% exceeds the minimum required score of 50%. The existing frontage road in front of the subject property would be re-routed to the west. This shifts the intersection of the frontage road and Foothills Parkway further west and relieves the congestion of the current situation. A new curb cut on Steele's east property line and the new frontage road allows circulation into the Steele's parking lot and the opportunity for shared parking. A right -in only, access point would be allowed off Foothills Parkway onto the existing frontage road. The two buildings would be constructed of an exterior material to match Steele's Market in order to promote a unified center. The Good Times building will feature a unique sloped roof to screen mechanical equipment and provide a form of identification. Outdoor seating is provided. The project is in conformance with the approved South College Access Control Plan. There are two conditions of approval relating to the effectiveness of screening the menu board from Foothills Parkway, and the final plat indicating recipro- cal cross -access easements for the re -aligned frontage road. DEVELOPMENT SERVICES 300 LaPorte Ave. P.O. Boa 580 Fort Collins, CO 80522-0580 (303) 221-6750 PLANNING DEPARTMENT Foothills Parkway AD., Preliminary - #36-89A November 20, 1989 P & Z Meeting Page 2 COMMENTS Background: The surrounding zoning and land uses are as follows: N: H-B; Dellenbach Chevrolet S: H-B; Colorado National Bank E: H-B; Goodyear Auto Service Center W: H-B; Steele's Market The site is legally described as Lot 2 of the Mourning Subdivision which was platted in 1973. No development has occurred on this parcel. The property is considered part of the Steele's Market development. 2. Land Use: As a repair facility and a drive-in restaurant, the project was evaluated as an Auto Related and Roadside Commercial use. The proposal achieves a score of 63% on the point chart which exceeds the 50% required minimum. Points were awarded for being located other than at the intersection of two arterial streets, being contiguous to and functionally a part of the Steele's Center, gaining primary access from a non -arterial street, and having direct vehicular and pedestrian access between on -site parking areas and adjacent, existing or future off -site parking areas which contain more than 10 spaces. Finally, points were earned for the site having contiguity to existing urban develop- ment. 3. Neighborhood Compatibility: No neighborhood meeting was held as the Foothills Parkway P.U.D. is consid- ered compatible with other existing uses on the "South College Avenue Corri- dor." 4. Design The Good Times restaurant is a drive-in facility with an interior order counter for pedestrian customers. There is no table service has been elimi- nated. There are two drive lanes, two menu boards and two pick-up windows. The southerly drive is the primary order lane with the northerly drive acting as an overflow lane during peak times. In case there is no passenger, an employee will deliver the order directly to the driver in the northerly lane. The Econo Lube is a combination tune-up, lubrication, and oil change facility. There are three drive through bays for oil and lube service and three regular bays for tune-ups. The primary design element of the P.U.D. is the re-routing of the existing frontage road as it intersects with Foothills Parkway. Currently, the frontage Foothills Parkway POD., Preliminary - #36-89A November 20, 1989 P & Z Meeting Page 3 road parallels College Avenue from Swallow Road on the north to Foothills Parkway on the south. Beginning at point equally dividing the Ecno Lube and Good Times, it is now proposed that the road turn west for a distance of 180 feet and then south to a new intersection with Foothills Parkway. The old intersection would be reduced to 14 feet in width and limited to right -in turns only. The old portion of the frontage road would be vacated and the new portion dedicated as a private access easement. The landscaping objective is to plant deciduous street trees around the perimeter of the site with the exception of coniferous trees to screen the restaurant's menu board and southerly drive lane along Foothills Parkway. The two buildings will use similar exterior materials as that of the Steele's Market. The objective is to promote a planned center with Steele's as the anchor and the two new uses as pad sites. The one exception to the architectural balance of the center is the sloped roof of the Good Times restaurant. This roof has a unique shape for two pur- poses. First, with only 770 square feet of floor area, it is difficult to screen the necessary rooftop mechanical equipment. Second, the roof becomes an identifiable characteristic much as other restaurants use a mansard design. The site features an outdoor seating area located along the frontage road with a sidewalk connection to the restaurant. This area is landscaped to promote a pleasing outdoor environment. There would be three freestanding monument signs. One would be a Steele's Center identification sign. The project I.D. sign is proposed to measure 22 feet in height and be located along Foothills Parkway behind the Good Times. Two signs would be provided for the tenants. These individual signs would be mounted on 3 foot high pedestals made of similar materials as the building exterior. The sign cabinets would measure 5.5 feet in height by 8 feet in length for a total of 44 square feet per face. Both signs would be double faced and internally illuminated. In addition, each building would feature wall signage. Staff is concerned about the size and screening of the menu board from Foothills Parkway. Menu boards are considered signage and the location on Foothills Parkway represents two freestanding signs along one frontage. The Sign Code only allows one sign per frontage per platted lot. In order to allow a menu board as the second freestanding sign along Foothills Parkway, the sign must be screened from view from the public right-of-way. Also, the square footage of the menu board must not so large that, when combined with the Steele's identification sign, total signage area does not exceed the 215 square feet allowed by the Sign Code. Since the amount of screening is critical, and the dimensions and schematic drawings are not yet available, Staff recommends the following condition be added to the preliminary approval: The amount of screen material in the area of the menu board and along Foothills Parkway shall be increased so that the menu board is not visible from the street. The screen material may consist of berming and landscaping. Foothills Parkway P.O.D., Preliminary - #36-89A November 20, 1989 P & Z Meeting Page 4 Parking on the site is minimal due to the drive-in nature of each use. Any overflow parking would be allowed to spill over onto the Steele's lot. A letter from Steele's Market that confirms the shared parking arrangement is enclosed. A 5 foot wide sidewalk will be constructed on the west side of the frontage road, and in front of the Good Times to provide pedestrian access through the site. 4. Transportation: The proposal to re-route the two-way frontage road traffic to the west is supported by the City's Traffic Engineering Staff as a means to minimize the current problems at the Foothills/frontage road/College Avenue intersection. Presently, the proximity of the frontage road intersection to College Avenue and the illegal u-turns around the median create congestion. Therefore, the vacation of the frontage road at this location provides a public benefit. The new private road will be a dedicated access easement and be 28 feet wide. Parking will not be allowed on this private street. The private street will feature vertical, concrete curb and gutter to establish a similar feel to a public street. There will continue to be right -in turns off Foothills Parkway onto the re -aligned frontage road. This turn lane will be reduced to 14 feet in width and will be designed to discourage southbound exits. A new curb cut along the east property line of Steele's Market would connect the Steele's parking lot with the new private street and the parking lot of proposed P.U.D. Steele's easterly curb cut on Foothills Parkway will be abandoned in favor of the new, internal access from the re -aligned frontage road. Recommendation: Staff finds the request for Preliminary P.U.D. for Foothills Parkway exceeds the minimum required score on the Auto Related and Roadside Commercial point chart. Also, the project meets the all development criteria of the Land Development Guidance System. Staff, therefore, recommends approval subject to the following conditions: 1. The final plat shall indicate reciprocal cross -access easements for the re -aligned frontage road and the right -in curb cut on Foothills Parkway. 2. The amount of screen material in the area of the menu board and along Foothills Parkway shall be increased so that the menu board is not visible from the street. The screen material may consist of berming and lands- caping. Develo&ent Services Planning MEMORANDUM TO: Planning and Zoning Board FROM: Ted Shepard, Project Planner RE: Foothills Parkway P.U.D., Condition of Approval for Shared Parking DATE: November 20, 1989 Upon advisement from City Attorney, the Planning Staff recommends a third condi- tion of approval be added to the Foothills Parkway Preliminary P.U.D. The pur- pose of the condition is to establish a more legally sound commitment to guarantee the shared access to the eight parking stalls located in the Steele's Market parking lot. • The parking to be shared consists of eight spaces immediately west of the Good Times restaurant. Unlike the letter from Russ Kates, representing Steele's Market, these eight spaces are not in the northeast corner but rather in the southeast corner of the parking lot. It is Staff's position that these eight spaces are more likely to be shared than those on the north of the drive aisle. • Staff recommends that this condition read as follows: At the time of Final P.U.D., the applicant shall provide a legal instrument, suitable for recording, designating the eight parking spaces immediately west of the Good Times restaurant as "shared parking." Such agreement shall be in the form of a non-exclusive parking easement executed by all the pertinent parties. 300 LaPorte Avenue - P.O. Box 580 - Fort Collins, CO 80522-0580 - (303) 221-6750 ::LRM1M i, I dl►._.. • ._ . MZ - ; F. -M�_, - LIT = MI IMMIRF.M. LVE Mv,TMA , elms Vn MM LANDSCAPE NOTES STEELES MARKET PARKING. LANDSCAPE LEGEND NOTES ® ,,...... <... ...,, x x.x...�...,.� ......�...,o .v.. «. �. •DELLENBACH CHEVROLET �I Zi wl Q 0W W J J 0 U ECONO� T LURE li TUNE. ffjlHIS� �rt �r.rtxerlc ntluw �' SIGN ELEVATIONS SITE STATISTICS IM OWNER'S CERTIFICATION w r.nlow. rlp w IMe1 own ar w 1+....4 fa.e1W se UI..IU .IM. N M.Mt urt.lr wt tM. ..u..Iw uMltlw W nft.l<tlw ..t IerU en ..1. ATTORNEY'S CERTIFICATION LEGAL DESCRIPTION UIS IS TO CE.[I[I Ixt1 a TIF M1 w I. 1 E[MIR[ IN[ ❑1L[ 1. Tww.. l A'OFKIiim v ,. ... ��. m.�. .. ...n... 'a, MO EST.f[IW tx.1 - — M[ MG..IETa3 p .fOU O iX[ Li[ - .11 AS MT... 1. [...f. '� ITT). 11-[1-111. ME .S S—T IT. u a . MTE. PLANNING 6 ZONING BOARD CERTIFICATION M•e.N_fl tM .I...Mf .M Ienlp .e.r..[ tM PRELIMINARY SITE 3 LANDSCAPE PLAN FOOTHILLS PARKWAY PUD edwerd g zdenJ ut..........�n... a �_ VICINITY MAP .......... .. . NORTH ELEVATION SOUTH ELEVATION - EAST ELEVATION - EMNO WOE. T E ar,rt„ar,e aneeo O O au s o • O O NORTH ELEVATION ++• • — - - - - - - - - - - WON .i■INNER i----s� 0 EAST ELEVATION In' f' SOUTH ELEVATION I,•'•"-•' gii =� MEN WEST WEST ELEVATION +.'•'-w — J F7�7 11 WEST ELEVATION 1- PRELIMINARY ELEVATIONS FOOTHILLS PARKWAY PUD edward g. zdenek 0 STEELE'S MARKET 200 WEST FOOTHILLS PARKWAY FORT COLLINS, CO 80525 October 17, 1989 Mr. Ted Shephard City of Fort Collins Planning Department 300 LaPorte Avenue Fort Collins, CO 80521 Dear Mr. Shephard: OCT 2Ono D i Steele's Market is aware of the proposed Foothills Parkway P.U.D. and have reviewed the most recent site plan with the architect. It is apparent to us that from time to time a spill over of cars from the drive-in restaurant and/or the quick lube shop will occur. In sight of this overflow we hereby grant permission for the use of our northeasterly six (6) parking spaces to accomodate any excess parking the proposed Foothills Parkway P.U.D. project may need. Sincerely, STEELE'S MARKET I� Q l Russ kates Corporate Secretary RC/dw CATES/egz E� PLANNING OBJECTIVES Foothills Parkway P.U.D. Master Plan and Preliminary P.U.D. Plan July 5, 1989 Development of two (2) lots at the intersection of two major streets (College Avenue and Foothills Parkway) is a ditticult task. The project is being considered as a Master Plan that includes the existing Steeles Supermarket to the west. Adjacent to the PUD are Colorado National Bank to the south, Dellenbach Chevrolet to the north, and Good Year Tire Store to the east. Important issues in the design of this project are: Transportation Architectural Compatibility Landscape Continuity Transportation solutions have been addressed in a trattic study prepared by Matt Delich. Included are an additional right in, right out access to College Avenue directly north of the PUD, a design in conformance with the south Fort Collins access plan. The trontage road to the east of the project will be aban- doned along With a portion of the right of way and replaced with private drives on the north and west of the project, providing easier, sater access to adjacent properties. In conjunction with this project the adjacent land owners have been approached and are negotiating additional access to Swallow Drive to the north of the project, turther improving circulation in the immediate area. Architectural compatibility is a ditticult issue since both users of the plan have unique architectural expressions as part of their marketing approach. We have coordinated the colors and textures of the buildings with those of Steeles Market. The unique shape of Good Times will be sheathed in 'drivit', the same color and material that exists on Steeles while the upper portion of the building will be colored similarly. Econo Lube and Tune will use similar materials and textures. A common outdoor dining area will be provided between the two buildings and be used as a landscaped element that is intended to tie two buildings together at a pedestrian level. Landscaping is an important issue in any commercial development and espe- cially this one. The design of the site must incorporate strong continuity with adjacent landscaping while borrowing parking and service areas and allowing identitication of the communicable uses and visibility consistant with satety for both pedestrians and vehicles. We have continued the regularly spaced street trees with trees of similar genus. The internal landscaping has been selected to screen unsightly areas (relocated pine trees located on the west of the building adjacent to the trash area) while providing an environment of changing color and texture throughout the growing season. FOOTHILLS/submit 0 We would estimate the peak shitt employees t use contlicts are being mitigated by a combined system. The energy consumption on the proposed minimized by use of glass doors to service bays and a radiant heating system that will maintain while providing comfort for employees working on Food Restaurant is small enough that the kitchen of the heating requirement for the facility. o number twelve (12). The land vehicular and pedestrian access Econo Lube facility is being to promote solar gain in winter, a lower ambient temperature vehicles. The Good Times Fast equipment provided the majority The applicable land use policies that the project meets are as follows: 3a. Promote maximum utilization of land within City 3b. Alternative transportation modes 14. Urban development standards 20. Understandable interrelationships 21. Primary access to College Avenue 22. Continuous development 24. Phased utilities 25. Directed growth 26. Available existing services 29. Services direct development 50. Mass transit used as a tool FOOTHILLSI/submit • ALL DEVELOPMENT: NUMBERED CRITERIA CHART ALL CRITERIA APPLICABLE CRITERIA ONLY CRITERION Is the criterion oopiicabte7 Will the criterion be satrstied'r If no, please explain .��``�F�" ,e F.� Yes No NEIGHBORHOOD COMPATABILITY 1 Social Compatability X 2. Neighborhood Character 3 Land Use Conflicts 4 Adverse Traffic Impact PLANS AND POLICIES 5. Comprehensive Plan PUBLIC FACILITIES & SAFETY 6. Street Capacity 7 Utility Capacity 8 Design Standards 9 Emergency Access 10 Security Lighting 11 Water Hazards RESOURCE PROTECTION 12 Soils & Slope Hazard X 13 Significant Vegetation x 14. Wildlife Habitat X 15 Historical Landmark 16 Mineral Deposit 17 Eco-Sensitive Areas 18 Agricultural Lands ENVIRONMENTAL STANDARDS 19 Air Quality x X 20 Water Quality 21. Noise 22. Glare & Heat 23. Vibrations 24 Exterior Lighting 25. Sewoges & Wastes SITE DESIGN 26 Community Organization X X 27 Site Organization X X 28 Natural Feotures 29 Energy Conservation 30 Shadows 31 Solar Access 32 Privacy X 33 Open Space Arrangement 34. Building Height 35 Vehicular Movement X X 36 Vehicular Design X X 37 Parking 38 Active Recreational Areas 39 Private Outdoor Areas 40 Pedestrian Convenience X X 41 Pedestrian Conflicts x 42 Landscaping/Open Areas 43 Landscaping/Buildings X X 44 Landscaping/Screening X X 45 Public Access 4,t, S,anS FOOTHILLS PAAwAY oRE41 m 1Nt4R Y p*- Auto- Related and ACTIVITY Roadside Commercia DEFINITION I. Those retail and wholesale commercial activities which are generally con- sidered and typically found along highways and arterial streets. Uses include: free standing department stores; auction rooms; automobile service stations, repair facilities, car washes; boat, car, trailer, motorcycle showrooms, sales and repair; fuel and ice sales; greenhouses and nurseries; warehouses and storage; repair or rental of any article; exterminating shops; drive-in restaurants; adult book stores; eating places with adult amusement or entertainment; adult photo studios; adult theatres; any uses intended to provide adult amusement or entertainment; and, other uses which are of the same general character. CRITERIA` Each of the following applicable criteria must be answered "yes" and implemented within the develop- ment plan. Yes No NA 1. Does the project gain its primary ❑ vehicular access from a street other than South College Avenue? 2. Are all repair, painting and body work activities, including storage of refuse and vehicular parts, planned to take place within an enclosed structure? 3. If the project contains any uses intended Elto provide adult amusement or entertainment, El 0 does it meet the following requirements: a. Is the use established, operated or maintained no less than 500 feet from a residential neighborhood, church and/or school meeting all the requirements of the compulsory education laws of the State of Colorado? b. Is the use established, operated or maintained no less than 1,000 feet from another similar use? continued -19- L] I • III 17 Yes No 4. DOES THE PROJECT EARN AT LEAST 50% OF THE MAXIMUM POINTS AS CALCULATED ON "POINT CHART D" ® ❑ FOR THE FOLLOWING CRITERIA? a. Is the activity located other than at the intersection of two arte- rial streets? b. Is the project contiguous to and functionally a part of an existing neighborhood or community/regional shopping center, office or industrial park? c. Is the primary access to the activity from a non -arterial street? d. Is the project on at least two acres of land? e. Does the project contain two or more significant uses (for instance, retail, office, residential, hotel/motel and recreation)? f. Is there direct vehicular and pedestrian access between on -site parking areas and adjacent existing or future off -site parking areas which contain more than ten (10) spaces? g. Does the activity reduce non-renewable energy usage, through the application of alternative energy systems, use of existing build- ings, and through committed energy conservation measures beyond that normally required by City Code? h. Is the project located with at least 1/6th of its property boundary contiguous to existing urban development? i. If the site contains a building or place in which a historic event occurred, which has special public value because of notable archi- tecture, or is of cultural significance, does the project fulfill the following criteria. i. Prevent creation of influences adverse to its preservation; ii. Assure that new structures and uses will be in keeping with the character of the building or place. Imitation of period styles should be avoided; and iii. Propose adaptive use of the building or place that will lead to its continuance, conservation, and improvement in an appropriate manner while respecting the integrity of the neighborhood. —20— W_ .. I� l FoOrH144s PARKWAY f RG4_1N1NAR Y AUTO -RELATED AND ROADSIDE COMMERCIAL POINT CHART D For All Critera Applicable Criteria Only Criterion Is The Criterion Applicable Yes No II ul IV Circle The Correct Score Yes VW' No Multiplier Points Earned 1x11 Maximum Applicable Points a, Notattwo arterials X X (21 0 2 4 b. Part of planned center X X 2 10 3 6 c. On non -arterial X X 2 0 4 8 8 d. Two acres or more X X I 2 'nl 3 0 6 e. Mixed -use X X 2 no 3 Q 6 f, Joint parking }( 1 2 3 g, Energy conservation X 1 2 0 4 8 h. Contiguity X X 0 5 10 10 i. Historic preservation 1 2 0 2 J. 1 1 1 2.01 k, 112101 1. 1 2 0 VW —Very Wel I Done Totals 31 V VI Percentage Earned of Maximum Applicable Points VNI =Vll (0 3 % Vil —21— GOOD TIMES DRIVE THRU BURGERS ECONO LUBE SITE ACCESS STUDY FOPT COLLINS, COLORADO APRIL 1989 Prepared for: Good Times Drive Thr•u Burgers 2121 30 th Street Boulder, CO 80301 Prepared by: MATTHEW J. DELICH, P.E. 3413 Banyan Avenue Loveland, Colorado 80538 Phone 303-669-2061 owl oar EXECUTIVE SUMMARY Restaurant and auto lube uses have been proposed in the northwest corner of the College/Foothills intersection in Fort Collins, Colorado. This site access study involved the steps of trip generation, trip distribution, trip assignment, capacity analysis, traffic signal warrant analysis, signal progression analysis, and accident analysis. This study Assessed the impacts of a fast food restaurant and an auto lube located on the northwest corner of the College/Foothills intersection in the short range (1991) and long range (2010) street system in the immediate vicinity. As a result of this analysis, the following is concluded: - The proposed uses are feasible from a traffic engineering standpoint. At full development as proposed, approximately 1100 trip ends will be generated at this site daily. - Current operation at the signalized College/Foothills intersection and the stop sign controlled Foothills/frontage road intersection is acceptable. Occasionally, the no U-turn regulation on Foothills Parkway is violated by vehicles exiting to Foothills Parkway westbound, then turning around the median to go eastbound. - In the short range future, the signalized College/ Foothills intersection operates acceptably with the existing geometrics and phasing. The Foothills/frontage road and Foothills./access intersections operate acceptably. In the short range future, the frontage road can continue to operate as a right-in/right-out at Foothills Parkway. The east Access to the Steele-s Market parking lot should be closed with alternative access provided via the driveway to this si te. - In the long range future, the College/Foothills intersection will operate acceptably during the peak hours. All accesses to the site from Foothills Parkway and the frontage road will operate acceptably. The existing frontage road intersection with Foothills Parkway should be changed to a right -in only. The majority of frontage road traffic should use an alternative route to the north and west of the site. This concept has been agreed upon by the property oviners/deve 1 opers in this area. - With the recommended control and geometrics., the accident rate should be at an acceptable level for typical urban conditions. - The long range accesses shovin in this report are in conformance with the South College Avenue Access Control •* • JO Plan. This should facilitate implementation of the access plan in this area. u n LJ m 0 ❑ OFFICES 0 0 SWALLOW ROAD DELLENBACH CHEVROLET C O co co Ui U C9 2 H N X W POSSIBLE FUTURE ACCESS ACCESS TO � STEELES —',�� r oo BANK Q I 61 P CSJSL�*FUTURE GO