HomeMy WebLinkAboutFOOTHILLS PARKWAY PUD - PRELIMINARY - 36-89 - CORRESPONDENCE - STAFF'S PROJECT COMMENTSDevelopMent Services Planning Department July 24, 1989 Mr. Ed Zdenek Edward G. Zdenek Architects 223 Linden Street, Suite 105 Fort Collins, CO. 80524 Dear Mr. Zdenek: • Staff has completed the review for the Foothills Parkway Master Plan and Preliminary P.U.D. The following comments are offered: Master Plan: 1. The Master Plan document should contain information relating to the parcel size, existing zoning, maximum height of structures, approximate commercial floor area, and estimated development schedule. 2. The Master Plan should also contain information and zoning of the surrounding property up to a distance of 150 feet exclusive of right-of-way. 3. Please correct the spelling of McClelland Drive. Preliminary P.U.D.: 4. There is a major issue with the proximity of the right -in only curb cut on Foothills Parkway being so close to College Avenue. Staff would prefer this cut be closed. 5. All private drives must be dedicated on the plat as public access easements. 6. The following comments pertain to the Drainage Report: A. The Drainage Report and Grading Plan must show basin lines, flow arrows, and concentration points. B. More information is needed on the time of concentration and C values. C. Off -site flows are mentioned but not addressed. Please address. D. A floodplain use permit is required at the time of building permit. 300 LaPorte Avenue • P.O. Box 580 • Fort Collins, CO 80522-0580 • (303) 221-6750 Foothills Parkway MO Plan . Page 2 7. The plan indicates that existing trees in the vacated frontage road median are to be removed and new trees planted. The City Forester advises that these trees have ten years of maturity and should not be removed. Please show all of these existing trees on the site plan. 8. With the vacation of the frontage road, the Parks and Recreation Department will no longer assume irrigation and mowing obligations of the median area. Any necessary modifications or removal of the irrigation system should be coordinated with Chuck Ainsworth, Parks and Recreation Department, 221-6660. Please be advised that the Parks and Recreation Dept. will not allow any disruption of the irrigation needs of the adjacent median areas during the construction period. 9. Water mains are existing in Foothills Parkway and South College frontage road. Either main may be tapped for service. 10. A sewer main is existing in Foothills Parkway, southwest of the site, and is the only sewer in the vicinity. A grease trap is needed for the restaurant, and a sand/oil trap may be needed for the auto pad if a wash facility is built. 11. It is not clear whether or not there will be any seating in the restaurant. If so, are seven spaces sufficient? 12. In front of both uses, the 17 foot parking stall has insufficient sidewalk width for vehicle overhang. The sidewalk width next to a 17 foot parking stall must be a minimum of 6 feet. 13. The exit lane for the restaurant drive-thru should have a stop sign before entering the parking lot drive aisle. 14. The northerly drive-thru lane will put the driver on the opposite side of the pick up window, and will only have stacking space for two cars. Please justify how this operation will work. 15. Landscape materials should be added to the east elevation (front) of the restaurant. Indeed the photograph supplied at conceptual review indicates a very stark front elevation. 16. The restaurant's trash enclosure should have shrub material located on the south side of wall. 17. Additional shrubs should be added to landscape strip along Foothills Pkwy. 18. Additional trees should be added to the landscaped area between the front of the restaurant and the frontage road . 19. The north, east, and west elevations of the Econo Lube should have increased shrub material, as well as the south elevation adjacent to the two trees. 20. The Econo Lube trash enclosure should add shrub material on all three sides. 21. Please add one tree to the parking lot island on the north next to the note "3S" on the site plan. Foothills Parkway Mor Plan • Page 3 22. Please add the following note: "All landscaping to be installed or secured with a letter of credit, performance bond, or escrow account for 125% of the valuation prior to the issuance of a certificate of occupancy." 23. Lot 1 has two freestanding signs. This is not allowed under the Sign Code. Only one freestanding sign per frontage is allowed. Private road frontage is not considered eligible for signage. One sign must be deleted. 24. Lot 2 indicates one freestanding sign with two menu boards. If menu boards exceed four square feet, they are considered freestanding signs. Since a property is only allowed one freestanding sign per frontage, Lot 2 has an excessive number of signs. The two menu boards would be allowed if: A. The menu boards do not exceed four square feet each. B. One menu board is deleted or reduced below four square feet. C. The menu boards are made invisible from the street or property line. D. A variance is obtained from the Zoning Board of Appeals. 25. Staff suggests that the pedestals for the two freestanding monument signs be reduced from three feet to two feet. Also, it is suggested that the heights of sign copy be reduced from 5.5 feet to 4.5 feet. Since both buildings are one story structures, and both will have wall signage, lowering the profile of the signs will enhance the overall scale of both lots and create a more pleasing streetscape. Also, given the fact that the restaurant is only 770 square feet, a smaller sign is more compatible with the proposed use. 26. Staff is concerned about the roof line of the Good Times restaurant. This concern was relayed to the applicant as far back as the conceptual review meeting of January 23, 1989. While Staff applauds the use of similar materials to match the Steele's Grocery, the roof line radically departs from the sense of compatibility from the center. There is a concern that the structure itself will be perceived as a novelty rather than a building with architectural integrity. It will be recalled that national franchises that originally offered fast food out of novel, peculiar structures (Arby's, Dairy Queen, Red Barn, and even McDonald's) have, over time, modified their architecture to reflect a more lasting quality. The Planning Staff is wrestling with the concept "novelty" architecture on our City's main street. 27. The site plan should consider possible locations of the electrical transformer. The transformer must serve both sites, be placed in a utility easement, be screened as best as possible, and be accessible from one side by a boom truck. 28. Note Number 4 should add: "... and with the restrictions noted on this P.U.D." 29. Please address whether or not there will be any shared parking with Steele's Market. If so, a letter from the Steele's will be in order. Foothills Parkway MO• Plan • ` Page 4 This concludes our comments at this time. Please note the schedule for August: Plan revisions due August 10, 1989 PMT's, 10 prints, and colored renderings due August 21, 1989. Please call our office at your convenience to discuss these comments and issues. Sincerely, -F-d —, Ted Shepard Project Planner xc: Joe Frank, Assistant Planning Director Mike Herzig, Development Engineer