Loading...
HomeMy WebLinkAboutKECHTER FARM MIXED-USE TOWNHOMES - PDP210006 - DOCUMENT MARKUPS - ROUND 2 - UTILITY PLANSKECHTER ROAD ZIEGLER ROADE. TRILBY ROAD FOSSIL CREEK RESERVOIR 12' - 24' -31" ROLLOVER CURB AND GUTTER FLUSH TRANSITION AT DRIVEWAYS 12' -2. 00% SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc. NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 25 CS1 COVER STEET1 Original Field Survery:Northern Engineering Project No. 1124-006 Date: February 2, 2021 MARCH 2021 CONTACT INFORMATION PROJECT TEAM:VICINITY MAP NORTH BENCHMARK: #1 NGS A 409 (NAVD88) Elevation=5039. 43 Basis of Bearings The Basis of Bearings is the East line of the Southeast Quarter of the Northeast Quarter of Section 8-6-68 as bearing North 00° 17' 16" East, and monumented as shown on the Plat.PROJECT BENCHMARKS:KECHTER TOWNHOMES PROJECT TEAM: Northern Engineering Services, Inc.Shane Ritchie 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 970) 221-4158 PLANNER/ LANDSCAPE ARCHITECT OWNER/APPLICANT SITE ENGINEER SHEET INDEX FIELD SURVEY BY: Northern Engineering Services, Inc.Bob Tessely, PLS 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 970) 221-4158 SITE SURVEYOR TYPICAL SECTIONS (MULTIFAMILY)1 CS1 COVER SHEET 2 CS2 GENERAL & CONSTRUCTION NOTES 3 EX1 EXISTING CONDITIONS & DEMOLITION PLAN 4 PV1 PAVING PLAN UTILITY SHEETS 5 OU1 OVERALL UTILITY PLAN 6 SS1 SANITARY LINE A ( E) PLAN & PROFILE 7 SS2 SANITARY LINE A (E) PLAN & PROFILE 8 ST1 STORM DRAIN A PLAN & PROFILE 9 ST2 STORM DRAIN A( S) & A(S)-1 PLAN & PROFILE 10 ST3 STROM DRAIN A2 PLAN & PROFILE 11 ST4 STORM DRAIN A2-2, A2-5 & A2-5.1 PLAN & PROFILE GRADING SHEETS 12 OG1 OVERALL GRADING PLAN 13 G1 GRADING PLAN 14 G2 GRADING PLAN ROADWAY SHEETS 15 R1 STREET A PLAN & PROFILE DETAIL SHEETS 16 D1 SITE DETAILS 17 D2 SITE DETAILS 18 D3 WATER DETAILS 19 D4 SANITARY SEWER DETAILS 20 D5 DRAINAGE DETAILS 21 D6 DRAINAGE DETAILS 22 D7 DRAINAGE DETAILS DRAINAGE SHEETS 23 EC1 EROSION CONTROL PLAN 24 EC2 EROSION CONTROL DETAILS PRELIMINARY DEVELOPMENT PLANS FOR UTILITY CONTACT LIST: *UTILITY COMPANY This list is provided as a courtesy reference only. Northern Engineering Services assumes no responsibility for the accuracy or completeness of this list. In no way shall this list relinquish the Contractor's responsibility for locating all utilities prior to commencing any construction activity. Please contact the Utility Notification Center of Colorado (UNCC) at 811 for additional information.PHONE NUMBER GAS-----------------Xcel Energy-----------------------------Pat Kreager ( 970) 225-7840 ELECTRIC--------City of Fort Collins Light & Power--Rob Irish (970) 224-6167 CABLE-------------Comcast----------------------------------Don Kapperman (970) 567- 0425 TELECOM.--------CenturyLink------------------------------- William Johnson (970) 377-6401 WATER------------Fort Collins-Lovelandwater district--Nate Ensley ( 970) 226- 3104 WASTEWATER-Fort Collins-Loveland water district--Nate Ensley (970) 226-3104 STORMWATER-City of Fort Collins Utilities-----------Shane Boyle (970) 221-6339 E N G I N E E R N GI EHTRON R N E N G I N E E R N GI EHTRON R N PROJECT SITE A TRACT OF LAND LOCATED IN THE NORTHEAST QUARTER OF SECTION 8, TOWNSHIP 6 NORTH, RANGE 68 WEST OF THE 6TH P.M., COUNTY OF LARIMER, STATE OF COLORADO Black Timber Land Company Russell Baker 417 Jefferson Street Fort Collins, CO 80524 970) 267-7721 land planning landscape architecture urban design H2O V.P. H2O V.P. C.O. S CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR W CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRRCONTROL IRRI S OIS OCONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRRCONTROL IRR CONTROLIRRCONTROLIRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRRCONTROL IRRCONTROL IRRCONTROL IRR VAULT F.O. D S S FOFOFOFOFOFOIRRIRRIRRIRRIRRIRR IRRIRRIRRIRR IRR IR R IRR IRR IRR IRR IRR IRR IRR IRR IRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRR XXXXXXXXXXFO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FOSTOPNOPARKING NO PARKING FND #6 REBAR W/3 1/2" ALUMINUM CAP FND NAIL & BRASS TAG, LS 32444 FND NAIL & BRASS TAG, LS 32444 FND #4 REBAR W/YPC, LS 32444 FND #4 REBAR W/YPC, LS 32444 FND #4 REBAR W/YPC, LS 32444 FND #4 REBAR W/YPC, LS 32444 STSTSTSTSTSTST284. 0' SSSSSSSS SS SAN MH RIM= 4923.47 INV=4910. 68 (N)INV=4910. 55 (S) SAAN MH RIM= 4927.24 INV=4917. 26 (NE)INV=4917. 07 (S) 158.1 LF @ 4.0%SAN MH RIM=4925.78 INV=4918. 48 (E)INV=4918. 31 (SW)108.8 LF @ 0.97 36.9 LF 24" RCP @ 0. 11% 93. 2 LF 24"RCP @ 0.14% EAST TRILBY ROAD ZIEGLER ROADD D D REMOVE AND REPLACE EXISTING SANITARY MH REMOVE AND REPLACE EXISTING SANITARY SEWER MANHOLE RIM = 4927.24 INV. IN = 4917. 26 ( NE)INV. OUT = 4917.07 (S)REMOVE AND REPLACE EXISTING 6" SANITARY LINE REMOVE AND REPLACE EXISTING 6" SANITARY LINE REMOVE EXISTING STROM INLET REMOVE & REPLACE 28' ± EXISTING 36" RCP STORM LINE DEMO EXISTING IRRIGATION LINE ( TYP.)EXISTING TREE TO BE REMOVED ( TYP.)DEMO 60'± OF ASPHALT,CURB & GUTTER DEMO 54'± OF ASPHALT, CURB & GUTTER PROJECT BOUNDARY EXISTING UNDERGROUND FIBER OPTICS LINE EXISTING STREET SIGN (TYP.)EXISTING STORM MANHOLE RIM = 4921.12 INV. IN = 4917. 61 (S)INV. OUT = 4917. 45 (N)EXISTING STORM MANHOLE RIM = 4923.71 INV. IN = 49115. 26 (S)INV. OUT = 4915. 21 (N)EXISTING STORM MANHOLE RIM = 4921.68 INV. IN = 4917. 32 (S) INV. OUT = 4917. 25 (N)EXISTING 5' SIDEWALK EXISTING 4.5' SIDEWALKEXISTING PEDESTRIAN RAMP EXISTING TREE TO REMAIN (TYP.)EXISTING CONCRETE/BRICK FENCE POST EXISTING 6' WOOD PICKET FENCE EXISTING SPLIT RAIL FENCE EXISTING STORM MANHOLE RIM = 4926.78 INV. IN = 4918.17 (E)INV. OUT = 4918.13 (SW)EXISTING SANITARY SEWER MANHOLE RIM = 4923.47 INV. IN = 4910.68 (N) INV. OUT = 4910. 55 (S) DEMO EXISTING IRRIGATION CONTROL BOX (TYP.)EXISTING IRRIGATION TIE IN LOCATION.SEE IRRIGATION PLANS FOR DETAILS 57' ± OF EXISTING SIDEWALK DEMO 88' ± OF EXISTING SIDEWALK EXISTING VERTICAL PIPE DEMO EXISTING VERTICAL PIPE TRILBY ROAD (ROW VARIES)PER KINARD JUNIOR HIGH SCHOOL MLD (05-S2463)LOT 1 KINARD JUNIOR HIGH SCHOOL MLD 05-S2463)ZIEGLER ROAD ( ROW VARIES) PER FOSSIL LAKE PUD FIRST FILING & KECHTERFARM PLANNED LAND DIVISION - FILING 1FOSSIL LAKE PUD FIRST FILINGTRILBY ROAD ( ROW VARIES) PER FOSSIL LAKE PUD FIRST FILING TRILBY ROAD ( ROW VARIES) PER FOSSIL LAKE PUDFIRST FILINGOUTLOT B FOSSIL LAKE PUDFIRSTFILING LOT 12 K E C H T E R F A R M P L A N N E D L A N D D I V I S I O N FI L I N G 1 LOT 13 LOT 14 T R A C T N LOT 3 KECHTER FARM MLD # 13-S3150 LOT 11 SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc. NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970. 221.4158northernengineering.comof 25 EX1 DEMOLITION PLANEXISTING CONDITIONS & 3 NORTH IN FEET ) 1 inch = ft.Feet04040 40 80 120 EXISTING ELECTRIC E LEGEND:G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING IRRIGATION BOX EXISTING GAS METER EXISTING TELEPHONE PEDESTAL EXISTING TREES (TO REMAIN)FIELD SURVEY BY:SUBSURFACE EXPLORATION BY:NOTES:EXISTING SANITARY SEWER SS EXISTING WATER W EXISTING FENCE X EXISTING WATER METER EXISTING FIRE HYDRANT EXISTING ELECTRIC VAULT PROJECT BOUNDARY EXISTING RIGHT- OF-WAY EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR VAULT ELEC CONTROL IRR EXISTING TREES (TO BE REMOVED) EXISTING CABLE CTV EXISTING FIBER OPTIC FO 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL, REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL.3.CONTRACTOR IS ENCOURAGED TO PERFORM DEMOLITION IN A MANNER THAT MAXIMIZES SALVAGE, RE-USE, AND RECYCLING OF MATERIALS. THIS INCLUDES APPROPRIATE SORTING AND STORING. IN PARTICULAR, DEMOLISHEDCONCRETE, ASPHALT, VAULT F.O. D S FOFOFOFOFOFOXXXXXXXXXXFO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FOEAST TRILBY ROAD ZIEGLER ROADD D DSSSWW WW WWSSSSSSS SSSSSSS SSSSS S SSSSE T TTT T TEEEEEEEEEEEE EEEEE EEGGGGGGG G G G G G GGGGGGGGGGGGGGGGGGGGE E E E E E E E E E E E E E E E EEE 24'SANITARY SEWER A( W)SEE SHEET SS1 SANITARY SEWER A( E)SEE SHEET SS2 STORM DRAIN A SEE SHEET ST1 STORM DRAIN A SEE SHEET ST1 STORM DRAIN A2 SEE SHEET ST3 STORM DRAIN A( S)SEE SHEET ST2 STORM DRAIN A2- 2 SEE SHEET ST4 STORM DRAIN A2- 5 SEE SHEET ST4 SANITARY SEWER A3 SEE SHEET SS1 1.5" WATER SERVICE METER ( TYP.)4" SANITARY SERVICE ( TYP.)CONNECT TO EXISTING SANITARY SEWER MANHOLE CONNECT TO EXISTING 36" STORM DRAIN CONNECT TO EXISTING WATER LINE CONNECT TO EXISTING WATER LINE STA. 10+00. 00 CONNECT TO EXISTING 8"x8" TAPPING SLEEVE 8" TAPPING VALVE w/ TB ( S)N:100484. 01 E:210221. 88 STA. 11+46. 91 45.00° BEND w/ TB N:100344. 86 E:210240. 63 STA. 14+44. 13 45.00° BEND w/ TB N:100315. 97 E:210525. 88 STA. 15+43. 23 45.00° BEND w/ TB N:100224. 62 E:210544. 57 PROJECT BOUNDARY BUILDING 1 BUILDING 2 BUILDING 3 BUILDING 4 BUILDING 5 BUILDING 6 STA. 11+20. 40 45.00° BEND w/ TB N:100363. 61 E:210221. 88 STA. 15+16. 78 45.00° BEND w/ TB N:100243. 32 E:210525. 87 STA. 12+86. 59 8"x6" TEE w/ TB 1 - FH ASSEMBLY ( N)1 - 6" GV ( N)1 - 8" GV ( E)N:100344. 86 E:210380. 31 26.51 LF 8" PVC S45°00'00" E 40.86 LF 8" PVC S44°59'41" E 26.44 LF 8" PVC S45°00'00" E 139.69 LF 8" PVC N90°00'00" E 72.65 LF 8" PVC S00°00'28" W 93.24 LF 8" PVC S89°47'23"E120.40 LF 8" PVCS00° 00' 00"E24' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT STORM DRAIN A2-5.1 SEE SHEET ST4 STORM DRAIN A(S)-1 SEE SHEET ST2 STA. 16+36.46 CONNECT TO EXISTING 8"x8" TAPPING SLEEVE 8" TAPPING VALVE w/ TB ( W)N: 100224. 28 E: 210637. 81 9' UTILITY EASEMENT 9' UTILITY EASEMENT GAS LINE SIZING TO BE DETERMINED)GAS LINE ELECTRIC LINE ELECTRIC LINE POWER TRANSFORMER ( TYP.)SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 25 OU1 OVERALL UTILITY PLAN5 NORTH IN FEET )1 inch = ft.Feet04040 40 80 120 NOTES:1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES.2.ALL WATER CONSTRUCTION SHALL BE PER FORT COLLINS- LOVELAND WATER DISTRICT DESIGN STANDARDS, LATEST EDITION, EXCEPT FOR THE STANDARDS RELATED TO THE WATER SERVICES, WHICH SHALL BE PER CITY OF FORT COLLINS STANDARDS, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR AS REQUIRED FOR ABNORMAL DEFLECTIONS.3.ALL SEWER CONSTRUCTION SHALL BE PER FORT COLLINS-LOVELAND WATER DISTRICT DESIGN STANDARDS SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST EDITION.4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE.5.ALL WATERLINES SHALL HAVE A MINIMUM OF 5' AND MAXIMUM OF 6' WATER LINE COVER FROM FINISHED GRADE TO TOP OF PIPE.6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD.7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES.8. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITHCITYOF FORTCOLLINSSTREET REPAIR STANDARDS.10. ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.11. ALL WATER SERVICES SHALL BE 3 4" UNLESS OTHERWISE NOTED. EXISTING LOT LINE EASEMENT LINE SPROPOSED SEWER SERVICE WPROPOSED WATER SERVICE EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND:G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARYSEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT W SS PROPOSED LOT LINE PROPOSED ROW EXISTING ROW EXISTING CABLE CTV CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND VAULT F.O. D S FOFOFOFOFOFOXXXXXXXXXXFO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FOEAST TRILBY ROAD ZIEGLER ROADKECHTER FARM HOME OWNERS 400 E SIMPSON ST. STE 200,LAFAYETTE, CO KENJO LEGACY LLC (. 50)6131 ZIEGLER RD FORT COLLINS, CO DDSSSWWWWWWSSSSSSSSSSSSSSSSSSSSSSSSE T TTT T TEEEEEEEEEEEE EEEEE EEGGGGGGG G G G G G GGGGGGGGGGGGGGGGGGGGE E E E E E E E E E E E E E E E EEE SANITARY SEWER A( W)SEE THIS SHEET SANITARY SEWER A( E)SEE THIS SHEET STORM DRAIN A SEE SHEET ST1 STORM DRAIN A SEE SHEET ST1 STORM DRAIN A2 SEE SHEET ST3 STORM DRAIN A(S)- 1 SEE SHEET ST2 STORM DRAIN A2-5. 1 SEE SHEET ST4 SANITARY SEWER A3 SEE THIS SHEET 4" SANITARY SERVICE ( TYP.)CONNECT TO EXISTING SANITARY SEWER MANHOLE PROJECT BOUNDARY SSMH A1 STA 11+58. 06 N: 100315. 46 E: 209958. 74 SSMH A3 STA 13+21. 65 N: 100351. 70 E: 210088. 34 SSMH A6 STA 17+60. 09 N: 100334. 24 E: 210492. 59 SSMH A4 STA 14+31. 66 N: 100287. 91 E: 210177. 96 SSMH A2 STA 12+66. 91 N: 100383. 45 E: 210043.74 SSMH A5 STA 15+16. 35 N: 100334. 24 E: 210248. 85 EX_SSMH A STA 10+00. 00 N: 100165. 68 E: 210009. 24 158.06 LF 6" PVC @ 0. 50%108.85 LF 6" PVC @ 0. 50%54.75 LF 6" PVC @ 0. 50%110.00 LF 6" PVC @ 0. 50%84.69 LF 6" PVC @ 0. 50%243.75 LF 6" PVC @ 0. 50%26.84 LF 6" PVC @ 0. 50%63.11 LF 6" PVC @ 0. 50%SAN CLEANOUT A3-2 STA 10+89.95 N: 100414.81 E: 210115.18 STORM DRAIN A(S) SEE SHEET ST2 WATER LINE A SEE SHEET OU1 FIRE HYDRANT ASSEMBLY WATER LINE A SEE SHEET OU1 BUILDING 1 BUILDING 2 BUILDING 3 BUILDING 4 BUILDING 5 BUILDING 6 STREET A 24'SAN CLEANOUT A3-1 STA 10+26. 84 N: 100351. 70 E: 210115. 18 24' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 6' UTILITY EASEMENT SSMH A7 STA 17+92. 15 N: 100311.57 E: 210515.26 SSMH A8 STA 10+26.84 N: 100285. 63 E: 210515. 25 32.06 LF 6" PVC @ 0. 50%25.94 LF 6" PVC @ 0.50%STORM DRAIN A2-5 SEE SHEET ST4 STORM DRAIN A2- 2 SEE SHEET ST4 4905 4910 4915 4920 4925 4930 4935 4940 4945 4905 4910 4915 4920 4925 4930 4935 4940 4945 9+5010+00 11+00 12+00 13+00 14+ 00EX_SSMH ASTA 10+00.00RIM 4923.5±INV. IN 4910.68 (N)158.06 LF 6" PVC @ 0.50%SSMH A1STA 11+ 58.06RIM 4927. 2± INV. IN 4911. 67 ( NE) INV. OUT 4911. 47 ( S) 108. 85 LF 6" PVC @ 0.50%SSMH A2STA 12+66.91RIM 4925. 8±INV. IN 4912.41 (SE)INV. OUT 4912.21 (SW)54.75 LF 6" PVC @ 0. 50%SSMH A3STA 13+21. 65RIM 4926. 4± INV. IN 4912.88 (SE) INV. IN 4913.43 ( E) INV. OUT 4912.68 (NW)110. 00 LF 6" PVC @ 0.50% EXISTING GROUND 4905 4910 4915 4920 4925 4930 4935 4940 4945 4905 4910 4915 4920 4925 4930 4935 4940 4945 9+50 10+00 11+00 11+50 26.84 LF 6" PVC @ 0.50%63.11 LF 6" PVC @ 0.50%SAN CLEANOUT A3-2STA 10+89.95RIM 4914.4±INV. OUT 4913.88 (S)SSMH A3STA 10+00.00RIM 4926.4±INV. IN 4912.88 ( SE)INV. IN 4913.43 (E)INV. OUT 4912.68 (NW)SAN CLEANOUT A3-1STA 10+26.84RIM 4914.1±INV. IN 4913.56 (N)INV. OUT 4913.56 (W)PROPOSED GROUND EXISTING GROUND SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 25 SS1 PLAN & PROFILESANITARY LINE A(W), & A36 NORTH IN FEET )1 inch = ft. Feet04040 40 80 120 SS2 PROFILE SCALE:SANITARY LINE A(W) STAMATCH LINESEE SHEET14+00SS2KEYMAP E. TRILBY ROAD ZIEGLER ROADEXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND:NOTES:1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES.2.ALL SANITARY CONSTRUCTION SHALL BE PER SOUTH FORT COLLINS SANITATION DISTRICT CONSTRUCTION STANDARDS, LATEST EDITION.3.MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEELPATHS. 4. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 5.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL STROM DRAINS, VAULT F.O. D S FOFOFOFOFOFOXXXXXXXXXXFO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FOEAST TRILBY ROAD ZIEGLER ROADKECHTER FARM HOME OWNERS 400 E SIMPSON ST. STE 200,LAFAYETTE, CO KENJO LEGACY LLC (. 50)6131 ZIEGLER RD FORT COLLINS, CO DDSSSWWWWWWSSSSSSSSSSSSSSSSSSSSSSSSE T TTT T TEEEEEEEEEEEE EEEEE EEGGGGGGG G G G G G GGGGGGGGGGGGGGGGGGGGE E E E E E E E E E E E E E E E EEE SANITARY SEWER A( W)SEE THIS SHEET SANITARY SEWER A( E)SEE THIS SHEET STORM DRAIN A SEE SHEET ST1 STORM DRAIN A SEE SHEET ST1 STORM DRAIN A2 SEE SHEET ST3 STORM DRAIN A(S)- 1 SEE SHEET ST2 STORM DRAIN A2-5. 1 SEE SHEET ST4 SANITARY SEWER A3 SEE THIS SHEET 4" SANITARY SERVICE ( TYP.)CONNECT TO EXISTING SANITARY SEWER MANHOLE PROJECT BOUNDARY SSMH A1 STA 11+58. 06 N: 100315. 46 E: 209958. 74 SSMH A3 STA 13+21. 65 N: 100351. 70 E: 210088. 34 SSMH A6 STA 17+60. 09 N: 100334. 24 E: 210492. 59 SSMH A4 STA 14+31. 66 N: 100287. 91 E: 210177. 96 SSMH A2 STA 12+66. 91 N: 100383. 45 E: 210043.74 SSMH A5 STA 15+16. 35 N: 100334. 24 E: 210248. 85 EX_SSMH A STA 10+00. 00 N: 100165. 68 E: 210009. 24 158.06 LF 6" PVC @ 0. 50%108.85 LF 6" PVC @ 0. 50%54.75 LF 6" PVC @ 0. 50%110.00 LF 6" PVC @ 0. 50%84.69 LF 6" PVC @ 0. 50%243.75 LF 6" PVC @ 0.50%STORM DRAIN A(S) SEE SHEET ST2 WATER LINE A SEE SHEET OU1 FIRE HYDRANT ASSEMBLY WATER LINE A SEE SHEET OU1 BUILDING 1 BUILDING 2 BUILDING 3 BUILDING 4 BUILDING 5 BUILDING 6 STREET A 24' 24' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 6' UTILITY EASEMENT SSMH A7 STA 17+92. 15 N: 100311.57 E: 210515.26 SSMH A8 STA 10+26.84 N: 100285. 63 E: 210515. 25 32.06 LF 6" PVC @ 0. 50%25.94 LF 6" PVC @ 0.50%STORM DRAIN A2-5 SEE SHEET ST4 STORM DRAIN A2- 2 SEE SHEET ST4 SANITARY SEWER A3 SEE SHEETSS1 4905 4910 4915 4920 4925 4930 4935 4940 4945 4905 4910 4915 4920 4925 4930 4935 4940 4945 14+0015+00 16+00 17+00 18+00 19+ 00SSMH A6STA 17+60.09RIM 4926.4±INV. IN 4915.67 (SE)INV. OUT 4915.47 ( W)243. 75 LF 6" PVC @ 0.50%SSMH A5STA 15+16.35RIM 4925.2±INV. IN 4914.25 (E)INV. OUT 4914.05 (SW)84.69 LF 6" PVC @ 0. 50% SSMH A4STA 14+31. 66RIM 4926.4± INV. IN 4913.63 ( NE)INV. OUT 4913.43 ( NW) 110.00 LF 6" PVC @ 0.50% PROPOSED GROUND EXISTING GROUND 18" HDPE STORM STA.=15+ 01. 75 INV.=4918.24 SSMH A8STA 10+26.84RIM 4925.7±INV. OUT 4916.16 (N)SSMH A7STA 17+92.15RIM 4926.3± INV. IN 4916.03 (S)INV. OUT 4915.83 (NW) 32.06 LF 6" PVC @ 0.50%25.94 LF 6" PVC @ 0.50%SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 25 SS2 PLAN & PROFILESANITARY LINE A(E)7 NORTH IN FEET ) 1 inch = ft.Feet04040 40 80 120 PROFILE SCALE:LINEMAT C H STA14+00SANITARY LINE A(E)STAMATCH LINESEE SHEET14+00SS1KEYMAP E. TRILBY ROAD ZIEGLER ROADEXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND:NOTES:1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUNDUTILITIES.2. ALL SANITARY CONSTRUCTION SHALL BE PER SOUTH FORT COLLINS SANITATION DISTRICT CONSTRUCTION STANDARDS, LATEST EDITION.3.MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.4.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD.5.MAINTAIN 10' HORIZONTAL AND18" VERTICAL MINIMUM SEPARATION BETWEEN ALL STROM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 6.ALL SINGLE-FAMILY SANITARY SEWER SERVICES TO BE 4" PVC.7.ALL SANITARY MANHOLES TO BE 4'Ø UNLESS NOTED OTHERWISE. 8.REFER TO THE PLAT FOR LOT