Loading...
HomeMy WebLinkAboutKECHTER TOWNHOMES - FDP210002 - DOCUMENT MARKUPS - ROUND 3 - UTILITY PLANSTTTTGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGEEEEEEEEEEEETE TEEEEEEEEEEEEEE E EEEE E E EEEEEE E EE E EEEEEE E EEEE GGGGGGGG GGGGGG G C/O C/O VAULT ELEC VAULT ELEC GAS S VAULT ELEC FES CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR LID HY DCONTROL IRR CONTROL IRR CONTROL IRRXX W WWXXXXX XXXXXXXXEEG G G G G G G G GGGGGGGW W W WWWSSSSSS SS XXX X X X X X X X X X X X X X XXXXXXXXXXXPOUDRE R-1 SCHOOL DISTRICT PARCEL NO. 8604000904 W W W W S S S WWS SWW W W W W WWWWWWWWWW W W W W W W W 12" RCP18" RCP 12" PVCPROPOSED TEE W/3-WAY VALVING (TYP.) PROPOSED 45° BEND (TYP.)PR SSMH A1-1 CONNECT TO EX WATER MAIN TAPPING SLEEVE W/ 8" GV (N) PROPOSED 45° BEND ( TYP.)RELOCATED FIRE HYDRANT PR SSMH A3 PROPOSED TRANSFORMER PROPOSED TRANSFORMER APPROXIMATE GAS LOCATION APPROXIMATE GAS LOCATION APPROXIMATE LOCATION OF CONNECTION TO EX GAS 4. 5' SIDEWALK4. 5' SIDEWALK4.5' SIDEWALKPROPOSED 8" SANITARYPROPOSED 8" WATERPROPOSED 8" SANITARYPROPOSED 8" WATERPROPOSED 8" WATERPROPOSED 8" WATER4. 5' SIDEWALK 6' UTILITY & DRAINAGE EASEMENT 4. 5' SIDEWALK 4.5' SIDEWALK4.5' SIDEWALK4. 5' SIDEWALK 30' FL-FL 53' R.O. W. 30' FL- FL 53' R. O.W. 4.5' SIDEWALK9' UTILITY EASEMENT 9' UTILITY EASEMENT 14' DRAINAGE EASEMENT 6' DRAINAGE EASEMENT ECLIPSE LANE 53' PUBLIC ROW)QUASAR WAY( 53' PUBLIC ROW) SAN MH RIM=4903.86 INV IN=4891. 42 (N) INV OUT=4891. 22 (E)16" ADS FL=4901.13 14' DRAINAGE EASEMENT 7' ACCESS EASEMENT 4. 5' SIDEWALKWHEELHOUSE WAY( 53' PUBLIC ROW) LOGGERS LANE 53' PUBLIC ROW) CACTUS CURVE(53' PUBLIC ROW) 9' UTILITY EASEMENT PROPOSED WATER METER PIT (TYP.) APPROXIMATE LOCATION OF CONNECTION TO EX GAS PROPOSED FIRE HYDRANT #1 PROPOSED TRANSFORMER PROPOSED TRANSFORMER PROPOSED TRANSFORMER 12" PVCW S W W PROPOSED TRANSFORMER PROPOSED WATER METER PIT (TYP.) PROPOSED WATER METER PIT (TYP.)PROPOSED WATER METER PIT (TYP.) W W W W W W 9' UTILITY EASEMENT 12" RCP 12" PVC12" PVC12" PVCSTORM DRAIN LINE A SEE SHEET ST1 STORM DRAIN LINE B SEE SHEET ST2 STORM DRAIN LINE G SEE SHEET ST2 SANITARY LINE A-1 SEE SHEET SS1 PROPOSED LIGHT PROPOSED LIGHT PROPOSED LIGHT PROPOSED LIGHT W W WW SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 35 U1 UTILITY PLAN8 NORTH IN FEET )1 inch = ft. Feet02020 20 40 60 KEYMAP KECHTER RD (C.R. 36)QUASARWAYU1 U2 NOTES:1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES.2.ALL WATER CONSTRUCTION SHALL BE PER FORT COLLINS - LOVELAND WATER DISTRICT, LATEST EDITION, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR AS REQUIRED FOR ABNORMAL DEFLECTIONS.3.ALL SEWER CONSTRUCTION SHALL BE PER SOUTH FORT COLLINS SANITATION DISTRICT SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST EDITION.4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE.5.ALL WATERLINES SHALL HAVE A 5- FT MINIMUM AND 6-FT MAXIMUM WATER LINE COVER FROM FINISHED GRADE TO TOP OF PIPE.6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES.8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITYOFFORT COLLINSSTREETREPAIR STANDARDS.10.ALL MANHOLE RIM ELEVATIONS ( EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 14"BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.11.ALL INDIVIDUAL WATER SERVICES SHALL BE 3/4". ALL DUAL WATER SERVICES SHALL BE 1" BETWEEN THE TAP ON THE MAIN AND THE BRANCH YOLK IN THE METER PIT.EXISTING LOT LINE EASEMENT LINE SPROPOSED SEWER SERVICE WPROPOSED WATER SERVICE EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND:G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARYSEWER PROPOSED TGGGGGGGGGGGG G G G G G G G G G G G GGGGGGGGGGGTEEEETT T EEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE E E EEE E EEEEEEEEEEEEEEEEEEEEEEETEEEE EEEEEEEE EEGGGGGGGGGGGGGG G G S VAULT ELEC W FES D S S D E VAULT ELEC T CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTVCTVTTTTT E E E E E E E EXXXXXXXXXXXX XXXE E E E E STSTST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST STSTSTST SSSSSS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SSSSSSC T V CTV CTV CTV CTV CTV CTV CTV CTV XXXXXELEC WWWWWWWWWWWWWWWWWWWWWWWWWW15' UTILITY EASEMENT REC. NO. 20190009470 FL=4899.09 FL=4891.67 INLET GRATE=4902.05 INV IN=4898.56 (N) INV OUT=4893.62 (E) 10.5 LF 18" RCP @ 5.05% STORM MH RIM=4898.51 INV IN=4891.06 (NE) INV OUT=4891.00 (W) 69.0 LF 18" RCP @ 0.88% STORM MH RIM=4897.11 INV IN=4889.02 (E) INV OUT=4888.97 (S) 18" PVC SAN MH RIM=4896.98 INV IN=4877.84 (W) INV OUT=4877.78 (SE) 24" PVCSAN MH RIM=4897. 39 INV IN=4877.69 ( NW)INV IN=4877.79 ( E)INV OUT=4877.59 ( S)69.0 LF 24" PVC @ 0. 13%SAN MH RIM=4898. 92 INV IN=4878.72 ( E)INV OUT=4878.57 ( W)402.9 LF 24" PVC @ 0. 19%18" RCP 376.6 LF 18" RCP @ 0. 53%POUDRE R-1 SCHOOL DISTRICT PARCEL NO. 8604000904 W W W W W W W W W W W W W W W S S S S W W S W S W W W W W W W W W CITY OF FORT COLLINS PARCELNO. 860912890115" RCP12" PVC15" RCP15" RCP15" RCP PR SANITARY SEWER CONNECTION ( TYP.)PR WATER SERVICE CONNECTION (TYP.) PR FIRE HYDRANT #2 PR TEE W/ 3-WAY VALVING ( TYP.)PR SSMH A1 PROPOSED SSMH A CONNECT TO EX SAN MAIN)PROPOSED STORM MH CONNECT TO EX STORM MAIN)PR SSMH A2 PR 45° BEND ( TYP.) PR TRANSFORMER PROPOSED TRANSFORMER APPROXIMATE GAS LOCATION APPROXIMATE GAS LOCATION APPROXIMATE GAS LOCATION PROPOSED8" WATER PROPOSED 8" SANITARY4.5' SIDEWALK4. 5' SIDEWALK4.5' SIDEWALK 30' FL-FL 53' R.O.W. 30' FL-FL 53' R. O. W.4. 5' SIDEWALK9' UTILITY EASEMENT 9' UTILITY EASEMENT CACTUS CURVE( 53' PUBLIC ROW) CACTUS CURVE 53' PUBLIC ROW)WHEELHOUSE WAY(53' PUBLIC ROW)14' DRAINAGE EASEMENT 7' ACCESS EASEMENT 4. 5' SIDEWALK4.5' SIDEWALK4.5' SIDEWALK 4.5' SIDEWALK 9' UTILITY EASEMENT POND 1 9' UTILITY EASEMENT 9' UTILITY EASEMENT RAIN GARDEN A KECHTER ROAD (C. R. 36)70' PUBLIC ROW) 9' UTILITY EASEMENT PROPOSED WATER METER PIT ( TYP.)CONNECT TO EX WATER MAIN W/ TAPPING SLEEVE AND VALVE RAIN GARDEN B PROPOSED TRANSFORMER PROPOSED TRANSFORMER PROPOSED TRANSFORMER 12" PVC12" PVCW W W S 9' UTILITY EASEMENT PROPOSED WATER METER PIT (TYP.) PROPOSED WATER METER PIT ( TYP.)CURB INLET 12" RC P 18" R C P 12" PVC12" PVC12" RCPSIDEWALK CHASE SIDEWALK CHASE STORM DRAIN LINE C SEE SHEET ST3 STORM DRAIN LINE D SEE SHEET ST3 STORM DRAIN LINE E SEE SHEET ST3 STORM DRAIN LINE F SEE SHEET ST3 SANTARY LINE A- 2 SEE SHEET SS2 SANITARY LINE A- 1 SEE SHEET SS1 STORM DRAIN LINE B SEE SHEET ST2 PROPOSED LIGHT PROPOSED LIGHT PROPOSED LIGHT PROPOSED LIGHT PROPOSED LIGHT CURB INLET IRRIGATION SERVICE W W SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 35 U2 UTILITY PLAN9 NORTH IN FEET )1 inch = ft.Feet02020 20 40 60 KEYMAP KECHTER RD (C.R. 36)QUASARWAYU1 U2 NOTES:1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES.2.ALL WATER CONSTRUCTION SHALL BE PER FORT COLLINS - LOVELAND WATER DISTRICT, LATEST EDITION, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR AS REQUIRED FOR ABNORMAL DEFLECTIONS.3.ALL SEWER CONSTRUCTION SHALL BE PER SOUTH FORT COLLINS SANITATION DISTRICT SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST EDITION.4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE.5.ALL WATERLINES SHALL HAVE A 5-FT MINIMUM AND 6-FT MAXIMUM WATER LINE COVER FROM FINISHED GRADE TO TOP OF PIPE.6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD.7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES.8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS.10. ALL MANHOLE RIM ELEVATIONS ( EXISTING & PROPOSED) ARETOBE ADJUSTEDTO14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.11. ALL INDIVIDUAL WATER SERVICES SHALL BE 3/4". ALL DUAL WATER SERVICES SHALL BE 1" BETWEEN THE TAP ON THE MAIN AND THE BRANCH YOLK IN THE METER PIT.EXISTING LOT LINE EASEMENT LINE SPROPOSED SEWER SERVICE WPROPOSED WATER SERVICE EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND:G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTINGFIRE HYDRANT TTT TG G GGG G G G G G G G G G G G G GGGGGGGGGGGGGGGGGGGGGGGGGGEEEEEEEET ETEEEEEEEEEEETTTEEEEEEEEEEEEEEEEEEEEEEEEEE E E E E E EEEEEE E E E T EEEEEEEEEEG G GGGG GGGGGGGC/ OC/ OGASSCONTROLIRRCONTROLIRRWETTTCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVT T TTEEEE E EEEEGGGGGGG G WWWWSTSTSTSTSTSTSTSTSTSTSTSSSSSSSSSSSSSSSSSSSSSSSSCTVCTVCTVCTVCTVXXXXXXXXELECWWWWWWWWWW181.68 LF 8" PVC @ 2.70%335.93 LF 8" PVC @ 1.50% SSMH A STA 10+ 00.00 N: 102553.08 E: 213403.65 SSMH A1 STA 11+ 81.68 N: 102734.69 E: 213398.76 SSMH A1-1 STA 15+ 17.61 N: 103070.50 E: 213389.71 SSMH A3 STA 15+ 11.21 N: 103078.09 E: 213561.84 338.89 LF 8" PVC @ 1.00% SSMH A2 STA 11+ 72.33 N: 102739.33 E: 213571.02 LOGGERS LANECACTUS CURVEWHEELHOUSE WAY QUASAR WAY CACTUS CURVE KECHTER ROAD ( C.R. 36)(70' PUBLIC ROW) PARCEL W WILLOW BROOK PARCEL R WILLOW BROOK STORM DRAIN LINE A SEE SHEET ST1 STORMDRAIN LINE B SEE SHEET ST2 STORM DRAIN LINE C SEE SHEET ST3 STORM DRAIN LINE D SEE SHEET ST3 STORMDRAIN LINE ESEESHEET ST3 STORM DRAIN LINE F SEESHEET ST3 30'FL-FL53' ROW STORM DRAIN LINE G SEE SHEET ST2 SANTARY LINE A-2 SEE SHEET SS2 7 ACCESS EASEMENT 9 UTILITY EASEMENT 9 UTILITYEASEMENT9 UTILITY EASEMENT 9 UTILITY EASEMENT 14 DRAINAGE EASEMENT 30' FL-FL53' ROW 15 UTILITY EASEMENT REC. NO. 20190009470 172. 33 LF 8" PVC @ 1.00% RAIN GARDEN B POND 1 RAIN GARDEN A APPROXIMATE LIMITS OF ASPHALT PATCH CLEANOUT AT BEND IN SAN SVC ( TYP.) CLEANOUT AT BEND IN SAN SVC ( TYP.) 487048754880488548904895490049054910 4915 4870 4875 4880 488548904895 4900 4905 49104915 9+5010+0011+0012+0013+0014+0015+0016+00 SSMH A(DROP MH) STA 10+00. 00RIM 4897.7± INV. IN 4886.71 ( N)INV. IN 4877.97 (E) INV. IN 4878. 96 (N)INV. OUT 4877.96 (W)SSMH A1STA 11+ 81.68RIM 4898.6± INV. IN 4891.81 (N)INV. IN 4891. 81 (E)INV. OUT 4891.61 ( S)SSMH A1-1STA 15+ 17.61RIM 4902.6± INV. OUT 4896. 85 (S)181.68 LF 8 P V C @ 2 7 0 335. 93 LF 8" PVC @ 1 5 0 STA.=10+80.39 INV.= 4891.88 15" RCP STORM 4897.344897. 354897.574897.884898. 204898.514898.824899.134899.444899. 754900. 074900.384900.694901. 004901.314901.634901.944902. 254902. 55PROPOSED GROUND EXISTING GROUND 18" MIN. STA.= 10+12. 89 INV.= 4889. 61 EX 18" RCP STORM STA.= 10+22.30 EX CABLE STA.= 10+27.82 EX CABLE STA.= 13+ 33. 32 PR ELECTRIC STA.=13+35.32 PR ELECTRIC STA.=15+40. 21 DESCRIPTION STA.=15+54.90 DESCRIPTION DROP MH DROP INVERT IN = CENTERLINE OF INVERT OUT PROPOSED GROUND EXISTING GROUND 18" MIN.SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 35 SS1 PLAN & PROFILESANITARY LINE A10 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow.before you dig.Call R KEYMAP KECHTER RD (C.R. 36)QUASARWAYNORTH IN FEET ) 1 inch = ft.Feet03030 30 60 90 SS1/SS2/SS3PROFILE SCALE: SANITARY LINE A1 EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND:NOTES:1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWNUNDERGROUNDUTILITIES. 2.ALL SANITARY CONSTRUCTION SHALL BE (LOCAL ENGINEERING STANDARD), LATEST EDITION. 3.MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.4.UTILITY SERVICES ARE SHOWN IN TTT TG G GGG G G G G G G G G G G G G GGGGGGGGGGGGGGGGGGGGGGGGGGEEEEEEEET ETEEEEEEEEEEETTTEEEEEEEEEEEEEEEEEEEEEEEEEE E E E E E EEEEEE E E E T EEEEEEEEEEG G GGGG GGGGGGGC/ OC/ OGASSCONTROLIRRCONTROLIRRWETTTCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVT T TTEEEE E EEEEGGGGGGG G WWWWSTSTSTSTSTSTSTSTSTSTSTSSSSSSSSSSSSSSSSSSSSSSSSCTVCTVCTVCTVCTVXXXXXXXXELECWWWWWWWWWW181.68 LF 8" PVC @ 2.70%335.93 LF 8" PVC @ 1.50% SSMH A STA 10+ 00.00 N: 102553.08 E: 213403.65 SSMH A1 STA 11+ 81.68 N: 102734.69 E: 213398.76 SSMH A1-1 STA 15+ 17.61 N: 103070.50 E: 213389.71 SSMH A3 STA 15+ 11.21 N: 103078.09 E: 213561.84 338.89 LF 8" PVC @ 1.00% SSMH A2 STA 11+ 72.33 N: 102739.33 E: 213571.02 LOGGERS LANECACTUS CURVEWHEELHOUSE WAY QUASAR WAY CACTUS CURVE KECHTER ROAD ( C.R. 36)(70' PUBLIC ROW) PARCEL W WILLOW BROOK PARCEL R WILLOW BROOK STORM DRAIN LINE A SEE SHEET ST1 STORMDRAIN LINE B SEE SHEET ST2 STORM DRAIN LINE C SEE SHEET ST3 STORM DRAIN LINE D SEE SHEET ST3 STORMDRAIN LINE ESEESHEET ST3 STORM DRAIN LINE F SEESHEET ST3 30'FL-FL53' ROW STORM DRAIN LINE G SEE SHEET ST2 SANTARY LINE A-2 SEE SHEET SS2 7 ACCESS EASEMENT 9 UTILITY EASEMENT 9 UTILITYEASEMENT9 UTILITY EASEMENT 9 UTILITY EASEMENT 14 DRAINAGE EASEMENT 30' FL-FL53' ROW 15 UTILITY EASEMENT REC. NO. 20190009470 172. 33 LF 8" PVC @ 1.00% RAIN GARDEN B POND 1 RAIN GARDEN A APPROXIMATE LIMITS OF ASPHALT PATCH CLEANOUT AT BEND IN SAN SVC ( TYP.) CLEANOUT AT BEND IN SAN SVC ( TYP.) 487048754880488548904895490049054910 4915 4870 4875 4880 4885 4890 4895 4900 4905 4910 4915 9+5010+0011+0012+0013+0014+0015+ 0016+00 SSMH A1STA 11+81. 68RIM 4898.6±INV. IN 4891. 81 (N)INV. IN 4891.81 ( E)INV. OUT 4891.61 (S) STA.=10+86.20 INV.= 4895.15 15" RCP STORM 172. 33 LF 8" PVC @ 1.00%4898. 594898. 364898.584898. 814899. 034899. 254899.424899.434899.754899.984900.194900.404900.624900. 834901.054901.264901.484901.694901.914902.124902.23PROPOSED GROUND EXISTING GROUND 18" MIN.8" WATERSTA.=10+ 10. 00TOP=4890.35STA.= 13+23.94PR ELECTRIC STA.= 13+25.94 PR ELECTRIC 6" WATER (FH SERVICE)STA.=14+ 82. 90TOP= 4895.3018" MIN.PROPOSED GROUND EXISTING GROUND STA.= 11+45.15 EX TELEPHONE (TO BE REMOVED)18" MIN. SSMH A2STA 11+72.33RIM 4899.4±INV. IN 4893.74 (N)INV. OUT 4893.54 (W)SSMH A3STA 15+11.21RIM 4902. 2±INV. OUT 4897.13 (S)338.89 LF 8" PVC @ 1.00%SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 35 SS2 PLAN & PROFILESANITARY LINE A11 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R KEYMAP KECHTER RD (C.R. 36)QUASARWAYNORTH IN FEET )1 inch = ft.Feet03030 30 60 90 SS1/SS2/ SS3PROFILE SCALE:SANITARY LINE A-2 EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND:NOTES:1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLEFORALL UNKNOWN UNDERGROUND UTILITIES.2. ALL SANITARY CONSTRUCTION SHALL BE (LOCAL ENGINEERING STANDARD), LATEST EDITION. 3.MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4.UTILITY SERVICES TTT TG G GGG G G G G G G G G G G G G GGGGGGGGGGGGGGGGGGGGGGGGGGEEEEEEEET ETEEEEEEEEEEETTTEEEEEEEEEEEEEEEEEEEEEEEEEE E E E E E EEEEEE E E E T EEEEEEEEEEG G GGGG GGGGGGGC/ OC/ OGASSCONTROLIRRCONTROLIRRWETTTCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVT T TTEEEE E EEEEGGGGGGG G WWWWSTSTSTSTSTSTSTSTSTSTSTSSSSSSSSSSSSSSSSSSSSSSSSCTVCTVCTVCTVCTVXXXXXXXXELECWWWWWWWWWWLOGGERS LANECACTUS CURVEWHEELHOUSE WAY QUASAR WAY CACTUS CURVE KECHTER ROAD ( C.R. 36)(70' PUBLIC ROW) PARCEL W WILLOW BROOK PARCEL R WILLOW BROOK STORMDRAIN LINE A SEE SHEET ST1 STORMDRAIN LINE B SEE SHEET ST2 STORM DRAIN LINE C SEE SHEET ST3 STORM DRAIN LINE D SEE SHEET ST3 STORMDRAIN LINE E SEE SHEET ST3 STORMDRAIN LINE F SEE SHEET ST3 STORMDRAIN LINE G SEE SHEET ST2 SANTARY LINE A- 2 SEE SHEET SS2 7 ACCESS EASEMENT 9 UTILITY EASEMENT 9 UTILITY EASEMENT 9 UTILITY EASEMENT 9 UTILITY EASEMENT 14 DRAINAGE EASEMENT 15 UTILITY EASEMENT REC. NO. 20190009470 RAIN GARDEN B POND 1 RAIN GARDEN A PR FIRE HYDRANT #1 PR FIRE HYDRANT #2 APPROXIMATE LIMITS OF ASPAHLT PATCH CONNECT TO EX WATER MAIN TAPPING SLEEVE W/ 8" GV (N) CONTRACTOR TO POTHOLE TO VERIFY DEPTH PRIOR TO CONSTRUCTION) N:102531. 75 E:213414.22 RELOCATED EX FH CONNECT TO EX WATER MAIN TAPPING SLEEVE W/ 8" GV (N) CONTRACTOR TO POTHOLE TO VERIFY DEPTH PRIOR TO CONSTRUCTION)N:103203.92 E:213443.72 STA. 15+43. 46 45.00° BEND w/ TB N:103073.00 E:213404.65 STA. 20+09. 69 45.00° BEND w/ TB N:102748.92 E:213555.75 STA. 15+78. 60 8"x8" TEE w/ TB 3- 8" GVs N:103071. 90 E:213439.76 STA. 11+60.75 8"x6" SWIVEL TEE w/ TB & 6" GV (E)N:102692.44 E:213409.91 STA. 12+13. 28 8"x8" TEE w/ TB 3-8" GVs N:102744.96 E:213408.49 6.87 LF 8" PVCN45°05'32"E 160. 75 LF 8" PVC N01°32'18"W52.54 LF 8" PVC N01° 32'39"W35.13 LF 8" PVCS88°12' 34"E7.07 LF 8" PVC S43°27' 08"W 147. 31 LF 8" PVCS88° 27'27"WSTA. 17+11. 76 8"x6" SWIVEL TEE w/ TB & 6" GV (W)N: 103044.81 E:213552. 73 STA. 16+93. 49 45.00° BEND w/ TB N:103063.07 E:213552.24 7.51 LF 8" PVC S43°12'34" E SANITARY LINE A- 1 SEE SHEET SS1 IRRIGATION SERVICE STA. 17+ 35.52 8" x4" TEE w/ TB N:103021.07 E:213553. 38 STA. 17+ 40.52 8" x4" TEE w/ TB N:103016.07 E:213553. 51 STA. 18+ 77.80 8" x4" TEE w/ TB N:102878.84 E:213557. 23 STA. 19+ 03.87 8" x4" TEE w/ TB N:102852.77 E: 213557.94 STA. 16+47. 51 8"x6" TEE w/ TB N:103069.75 E: 213508.64 STA. 11+48. 07 8"x6" SWIVEL TEE w/ TB & 6" GV (W)N: 103199.92 E:213443. 61 STA. 10+87.84 8"x4" TEE w/ TB N:103139.72 E: 213441.81 60.23 LF 8" PVC N01°42' 19"E 87.84 LF 8" PVC N01°43' 41"E 68.91 LF 8" PVCS88°12'34" E38.48 LF 8" PVCS88°12'34"E18.27 LF 8" PVC S01° 33'11"E 23.75 LF 8" PVC S01° 33'11"E 5.00 LF 8" PVC S01° 33'11"E 137.28 LF 8" PVC S01° 33'11"E 26.07 LF 8" PVC S01° 33'11"E 98.75 LF 8" PVC S01° 33'11"E 97.09 LF 8" PVC N01° 32'33"W 16. 86 LF 8" PVC N01° 32'33"W 141.10LF8" PVC N01° 32'33"W 12.75 LF 8" PVC N01°32'33" W 47.99 LF 8" PVC N01°32'33" W STA. 20+ 02.62 45. 00° BEND w/ TB N: 102754.06 E:213560. 61STA. 16+85.98 45.00° BEND w/ TB N:103068.55 E:213547.10 STA. 15+36.59 45.00° BEND w/ TB N:103068.15 E:213399.78 7.51 LF 8" PVC N01°36'57"W STA. 12+20. 79 8"x4" TEE w/ TB N: 102752.46 E:213408.28 STA. 13+17. 88 8"x4" TEE w/ TB N: 102849.52 E:213405.67 STA. 13+34. 74 8"x4" TEE w/ TB N: 102866. 37 E: 213405. 21 STA. 14+ 88. 60 8" x4" TEE w/ TB N: 103020. 17E:213401.07STA. 14+75.858" x4" TEE w/ TB N:103007.43 E:213401.42 4870 4875 4880 4885 4890 48954900490549104915 4870 4875 4880 4885 4890 4895 4900 4905 4910 4915 9+5010+ 0011+0012+0013+ 0014+0015+0016+00 STA.=10+34.18 INV.= 4889. 66 EX 18" RCP STORM STA.=10+ 43.31 EX CABLESTA.= 10+48. 20 EX CABLE STA.= 10+53. 10 EX ELECTRIC STA.= 11+01. 99 INV.= 4891.83 PR15" RCP STORM STA.= 11+69.78 PR GAS STA.= 12+03.28 INV.= 4891.92 PR 8" PVC SANITARY EXISTING GROUND 4897.114897. 174897.414897.734898.054898. 354898.654898. 974899.294899. 604899.914900. 224900.534900. 844901. 164901. 474901.784902.094902.474902.774902.884902.88STA.=13+ 54.93 PR ELECTRIC STA.=13+56.93 PR ELECTRIC PROPOSED GROUND EXISTING GROUND PROPOSED GROUNDSTA. 15+ 43.4645° BEND w/ TBT.O.P.= 4897. 25STA. 15+78. 608"X8" TEE w/ TB & 3-8" GVsT.O. P.= 4897.43STA. 11+60. 75FH ASSEMBLY8" X6" SWIVEL TEE w/ TB & 6" GV (E)T. O. P.=4889.94STA. 12+13.288"X8" TEE w/ TB & 3-8" GVsT.O.P.=4889.94STA. 12+20.798"X4" SWIVEL TEE W/ 4" GV (W)T.O.P.=4890.36STA. 13+17.888"X4" TEE W/ 4" GV (E)T.O. P.=4894.22STA. 13+34.748"X4" TEE W/ 4" GV (W)T.O.P.=4894.46STA. 14+ 75.858" X4" TEE W/ 4" GV (W)T.O.P.=4896.46STA. 14+88.608"X4" TEE W/ 4" GV (E)T. O.P.=4896.65STA. 15+36.5945° BEND W/ TBT.O. P.=4897.19184.5' DEF.STA. 14+90.70T.O.P.=4896.68(@ 0. 1°)71.0' DEF.STA. 12+42.05T.O. P.=4893.65STA. 13+13.04T.O.P.=4894.15(@ 0. 2°)STA. 10+ 00.0CONNECT TO EX WATER MAINTAPPING SLEEVE W/ 8" GV(CONTRACTOR TO POTHOLE PRIOR TOCONSTRUCTION TO VERIFY DEPTH)T.O.P.=4891.85STA. 10+51.245.00° BENDT.O.P.=4889.94STA. 12+18.711. 25° BENDT.O.P.=4889.94STA. 12+37.311.25° BENDT. O.P.=4893.65STA. 10+49.245. 00° BENDT.O.P.=4887.96STA. 10+15.345.00° BENDT. O.P.=4891.85STA. 10+19. 245.00° BENDT.O.P.=4887.96STA.=10+21.17 INV.= 4877.99 EX 24" PVC SANITARY 18" MIN.18" MIN. 18" MIN.8" PVC 8" PVC 8" PVC WT1 PLAN & PROFILEWATER LINE15 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow.before you dig.Call R NORTH IN FEET )1 inch = ft. Feet03030 30 60 90 WT1/WT2/WT3PROFILE SCALE:LINE MATCH STA 16+00 WATER LINE STAMATCH LINESEE SHEET16+00WT2SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 35 KEYMAP KECHTER RD (C.R. 36)QUASARWAYNOTES:1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND