Loading...
HomeMy WebLinkAboutPipe Sizing Letter_Sam's Club Fuel_Rd4 1805 N. 2 nd St. | Rogers, AR 72756 | 479.636.5004 | http://teamofchoice.com/about -us/jason -m -scates -p -e/ 3/29/21 Re: Sam's Club #6633 Fuel Kiosk water sizing calculations To whom it may concern: The pipe sizing calculation attached includes a list of all fixtures used in the kiosk. Fixture units are assigned to each fixture as outlined in the international plumbing code. Sanitary Sewer (SS), Cold Water (CW), Hot Water (HW) and the total of CW and HW. The resulting total water supply fixture units is 10, which equates to a flow rate of 15 gallons per minute per Table E103.3(3). A pipe size of 1" is selected for the water supply to the kiosk to keep the velocity below 8 feet per second. Sincerely, Jason M. Scates, P.E. Mechanical Engineer Water sizing calc - Sam's 192 Fuel Kiosk #6633 Fort Collins, CO Fixture SS CW HW CW+HW FD1-EquipRoom 5 0 0 0 FPWH1 0 3 0 3 L1 1 1.5 1.5 2 FD1-Toilet 5 0 0 0 WC8 4 5 0 5 Total FU 15 9.5 1.5 10 GPM ---14.6 5 15 Min Size Required 3"---1/2"1" IPC