HomeMy WebLinkAboutSAMS CLUB FUEL STATION - MJA200002 - SUBMITTAL DOCUMENTS - ROUND 4 - ARCHITECTURAL DETAILSCANOPY SIGN ABOVE,
REF ELEV
CANOPY SIGN
ABOVE, REF ELEV
CANOPY SIGN
ABOVE, REF
ELEV
CANOPY SIGN
ABOVE, REF ELEV
LINE OF CANOPY
(ABOVE)
CANOPY COLUMN
REF STRUCTURAL
FOR FOUNDATION (TYP)
FIRE EXTINGUISHER CABINET THIS
SIDE OF COLUMN
FIRE EXTINGUISHER
CABINET THIS SIDE OF
COLUMN
DIESEL FLAG AT OUTBOARD
SIDE OF CANOPY COLUMN
CONC SLAB UNDER
CANOPY
CONC SLAB OVER
UNDERGROUND STORAGE
TANKS
6"86'-8"6"6"40'-0" 6"
UNDERGROUND STORAGE
TANKS
FUEL TANK VENT
CL TANK
CL TANK
CL TANK
ARCHITECTURAL FINISH FLOOR (SERVICE BUILDING) = (F) 100'-0"
ALL EXTERIOR DOORS (SERVICE BUILDING) = (F) 100'-0"
SITE PAVING TO BE FLUSH W/ TANK SLAB, SERVICE BUILDING
APRON, AND CANOPY SLAB, REF CIVIL
SIM
SIM/OHEQEQ41'-0"43'-0"87'-8"
DIGITAL PRICE SIGN
ABOVE, REF ELEV
DIGITAL PRICE SIGN
ABOVE, REF ELEV
DIGITAL PRICE SIGN
ABOVE, REF ELEV
DIGITAL PRICE
SIGN ABOVE,
REF ELEVRIDGE
RIDGEFSA1
2
FSA1 3
46'-2"6'-3 5/8"
3'-2" (F.V.)
3'-2" (F.V.)
FSA1
2
FSA13
STEEL PIPE BOLLARD (TYP)
FUEL KIOSK,
REF 1-FSA2
BUILDING ADDRESS,
REF ELEV
BUILDING ADDRESS,
REF ELEV
CANOPY PANEL TO BE PREFINISHED
BY CANOPY MANUFACTURER TO
MATCH
PAINT SPLIT-FACE CMU
COLUMN
(TYP)
SIGNAGE DISPENSER
NOTE:
B.O. CANOPY SHALL HAVE MINIMUM 14'-0" CLEARANCE
TO FINISHED GRADE AT ALL POINTS UNDER CANOPY.
ELEVATION DOES NOT REFLECT SITE SLOPE.
PIPE BOLLARD
(TYP)EQEQ14'-0" MIN. 3'-4"
REF CIVIL
FINISHED GRADE
P38
P38
DIGITAL PRICE
SIGN (UNLEADED)
DIGITAL PRICE
SIGN (DIESEL)
BO CANOPY
113' -9"
TO CANOPY
117' -1"
STANDING SEAM ROOF AND FASCIA
BY CANOPY MANUFACTURER
3
12
16'-0"
PF4
1'-2"BUILDING ADDRESS
NUMBERS, MINIMUM 8"
HIGH IN CONTRAST TO
BACKGROUND,
WHERE SHOWN ON PLAN
CANOPY PANEL TO BE
PREFINISHED BY CANOPY
MANUFACTURER TO MATCH
SIGNAGE
NOTE:B.O. CANOPY SHALL HAVE MINIMUM 14'-0"
CLEARANCE TO FINISHED GRADE AT ALL POINTS UNDER
CANOPY. ELEVATION DOES NOT REFLECT SITE SLOPE.
DIGITAL PRICE
SIGN (UNLEADED)
DIGITAL PRICE
SIGN (DIESEL)EQEQ3'-4"13'-9"REF CIVIL
FINISHED GRADE
P38
PAINT SPLIT-FACE CMU COLUMN
(TYP)
BO CANOPY
113' -9"
TO CANOPY
117' -1"
STANDING SEAM ROOF AND FASCIA
BY CANOPY MANUFACTURER
P38
PF100
16'-0"1'-2"BUILDING ADDRESS
NUMBERS, MINIMUM 8"
HIGH IN CONTRAST TO
BACKGROUND,
WHERE SHOWN ON PLAN
SHEET:
DRAWN BY:
CHECKED BY:
PROTO CYCLE:
DOCUMENT DATE:CONSULTANTSPROTO:JOB NUMBER:FILE NAME:
NOT FOR
CONSTRUCTION
............................STIPULATION FOR REUSETHIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT:CONTEMPORANEOUSLY WITH ITS ISSUE DATE ON AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS AND ENGINEERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND MAY BE CONTRARY TO THE LAW.ARCHITECT OF RECORD:
8131 METCALF AVENUE
SUITE 300
OVERLAND PARK, KS 66204
www.brrarch.com
TEL: 913-262-9095
FAX: 913-262-9044
FSA1
CANOPY
JT4700 BOARDWALK DRFORT COLLINS, CO96530228192-FSA1
XX/XX/XXFORT COLLINS, COXX/XX/XXCLUB NO.: 6633-212SAM6-192 SAM6-192FUEL STATIONCOLOR LEGEND
P38 "PORTABELLO" SW #6102
PF4 STANDING SEAM METAL ROOF LEAD-COTE
1/8" = 1'-0" FSA121OVERALL PLAN
1/8" = 1'-0" FSA112FRONT AND BACK ELEVATION
1/8" = 1'-0" FSA113SIDE ELEVATION
ISSUE BLOCK