Loading...
HomeMy WebLinkAboutSAMS CLUB FUEL STATION - MJA200002 - SUBMITTAL DOCUMENTS - ROUND 4 - ARCHITECTURAL DETAILSCANOPY SIGN ABOVE, REF ELEV CANOPY SIGN ABOVE, REF ELEV CANOPY SIGN ABOVE, REF ELEV CANOPY SIGN ABOVE, REF ELEV LINE OF CANOPY (ABOVE) CANOPY COLUMN REF STRUCTURAL FOR FOUNDATION (TYP) FIRE EXTINGUISHER CABINET THIS SIDE OF COLUMN FIRE EXTINGUISHER CABINET THIS SIDE OF COLUMN DIESEL FLAG AT OUTBOARD SIDE OF CANOPY COLUMN CONC SLAB UNDER CANOPY CONC SLAB OVER UNDERGROUND STORAGE TANKS 6"86'-8"6"6"40'-0" 6" UNDERGROUND STORAGE TANKS FUEL TANK VENT CL TANK CL TANK CL TANK ARCHITECTURAL FINISH FLOOR (SERVICE BUILDING) = (F) 100'-0" ALL EXTERIOR DOORS (SERVICE BUILDING) = (F) 100'-0" SITE PAVING TO BE FLUSH W/ TANK SLAB, SERVICE BUILDING APRON, AND CANOPY SLAB, REF CIVIL SIM SIM/OHEQEQ41'-0"43'-0"87'-8" DIGITAL PRICE SIGN ABOVE, REF ELEV DIGITAL PRICE SIGN ABOVE, REF ELEV DIGITAL PRICE SIGN ABOVE, REF ELEV DIGITAL PRICE SIGN ABOVE, REF ELEVRIDGE RIDGEFSA1 2 FSA1 3 46'-2"6'-3 5/8" 3'-2" (F.V.) 3'-2" (F.V.) FSA1 2 FSA13 STEEL PIPE BOLLARD (TYP) FUEL KIOSK, REF 1-FSA2 BUILDING ADDRESS, REF ELEV BUILDING ADDRESS, REF ELEV CANOPY PANEL TO BE PREFINISHED BY CANOPY MANUFACTURER TO MATCH PAINT SPLIT-FACE CMU COLUMN (TYP) SIGNAGE DISPENSER NOTE: B.O. CANOPY SHALL HAVE MINIMUM 14'-0" CLEARANCE TO FINISHED GRADE AT ALL POINTS UNDER CANOPY. ELEVATION DOES NOT REFLECT SITE SLOPE. PIPE BOLLARD (TYP)EQEQ14'-0" MIN. 3'-4" REF CIVIL FINISHED GRADE P38 P38 DIGITAL PRICE SIGN (UNLEADED) DIGITAL PRICE SIGN (DIESEL) BO CANOPY 113' -9" TO CANOPY 117' -1" STANDING SEAM ROOF AND FASCIA BY CANOPY MANUFACTURER 3 12 16'-0" PF4 1'-2"BUILDING ADDRESS NUMBERS, MINIMUM 8" HIGH IN CONTRAST TO BACKGROUND, WHERE SHOWN ON PLAN CANOPY PANEL TO BE PREFINISHED BY CANOPY MANUFACTURER TO MATCH SIGNAGE NOTE:B.O. CANOPY SHALL HAVE MINIMUM 14'-0" CLEARANCE TO FINISHED GRADE AT ALL POINTS UNDER CANOPY. ELEVATION DOES NOT REFLECT SITE SLOPE. DIGITAL PRICE SIGN (UNLEADED) DIGITAL PRICE SIGN (DIESEL)EQEQ3'-4"13'-9"REF CIVIL FINISHED GRADE P38 PAINT SPLIT-FACE CMU COLUMN (TYP) BO CANOPY 113' -9" TO CANOPY 117' -1" STANDING SEAM ROOF AND FASCIA BY CANOPY MANUFACTURER P38 PF100 16'-0"1'-2"BUILDING ADDRESS NUMBERS, MINIMUM 8" HIGH IN CONTRAST TO BACKGROUND, WHERE SHOWN ON PLAN SHEET: DRAWN BY: CHECKED BY: PROTO CYCLE: DOCUMENT DATE:CONSULTANTSPROTO:JOB NUMBER:FILE NAME: NOT FOR CONSTRUCTION ............................STIPULATION FOR REUSETHIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT:CONTEMPORANEOUSLY WITH ITS ISSUE DATE ON AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS AND ENGINEERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND MAY BE CONTRARY TO THE LAW.ARCHITECT OF RECORD: 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 FSA1 CANOPY JT4700 BOARDWALK DRFORT COLLINS, CO96530228192-FSA1 XX/XX/XXFORT COLLINS, COXX/XX/XXCLUB NO.: 6633-212SAM6-192 SAM6-192FUEL STATIONCOLOR LEGEND P38 "PORTABELLO" SW #6102 PF4 STANDING SEAM METAL ROOF LEAD-COTE 1/8" = 1'-0" FSA121OVERALL PLAN 1/8" = 1'-0" FSA112FRONT AND BACK ELEVATION 1/8" = 1'-0" FSA113SIDE ELEVATION ISSUE BLOCK