Loading...
HomeMy WebLinkAboutBANK OF COLORADO DRIVE-THRU AT W ELIZABETH - FDP210007 - SUBMITTAL DOCUMENTS - ROUND 1 - SITE, LANDSCAPE & ELEVATIONS PLANSBANK OF COLORADO WESTERLY 68.49 FEET OF LOT 1, SECOND CAMPUS WEST SUBDIVISION Located in the S.E. Corner of Section 15, Township 7 North, Range 69 West of the Sixth Principal Meridian City of Fort Collins, County of Larimer, State of Colorado Land-Use Statistics: EXISTING ZONING: GROSS LAND AREA: TOTAL LAND AREA: NUMBER OF BUILDINGS: PROPOSED LAND USE: EXISTING LAND USE: TOT AL STORIES: PROPOSED BUILDING AREA: GROSS AREA COVERAGE BUILDING FOOTPRINTS LANDSCAPE AREA PAVED DRIVES AND PARKING SIDEWALKS/ PATHS TOTAL AREA: OFF-STREET PARKING: SPACES REQUIRED: CC -COMMUNITY COMMERCIAL 10,975S.F. 10,975S.F. 1 PROPOSED BANK (FINANCIAL SERVICES) CAR WASH (TO BE REMOVED) 895SQ. FT. SQUARE FEET ACRES 895 0.021 2,187 0.050 6,421 0.147 1,472 0.034 10,975 0.252 FINANCIAL SERVICES= 895 SQ. FT. (PROPOSED) 2 / 1,000 s.f. MINIMUM, OR 3.5 / 1,000 s.f. MAXIMUM SPACES PROVIDED: FINANCIAL SERVICES 5 STANDARD SPACES (9' X 17') 1 ADA ACCESSIBLE SPACE (9' X 17') BICYCLE PARKING: PER LUC SECTION 3.2.2 (C) 4 (b): REQUIRED: 1/ 4,000 SQ. FT., MIN. 4 PROVIDED: 4SPACES %OF 8% 20% 59% 13% 100% Vicinity Map: ~ NOT TO SCALE NORTH ,~;~ m __ :\\·:'.- e,,mM: It t-1 ·~r•i~\~ ir·~-~----,,r~---"~---~-1-------, WPl,m Owner's Certification of Approval: ,,/" / Ba1 D,- --• ! THE UNDERSIGNED DOES/DO HEREBY CERTIFY THAT I/WE ARE TI,E LAWFUL OWNERS OF REAL PROPERlY DESCRIBED ON THIS SITE PLAN AND DO HEREBY CERTIFY THAT I/WE ACCEPT TI,E CONDITIONS AND RESTRICTIONS SET FORTH ON SAID SITE PLAN. IN WITNESS WHEREOF, WE HAVE HEREUNTO SET OUR HANDS AND SEALS THIS TI-IE ___ DAY OF --------~20 __ _ BY: NOTARIAL CERTIFICATE STATE OF COLORADO) COUNTY OF ___ ~ THE FOREGOING INSTRUMENT WAS ACKNOWLEDGED BEFORE ME BY ________ _ THIS DAY OF _________ ~ 20 __ _ MY COMMISSION EXPIRES:. ____ _ NOTARY PUBLIC (SEAL) Planning Approval: BY THE DIRECTOR OF COMMUNllY DEVELOPMENT AND NEIGHBORHOOD SERVICES OF THE CITY OF FORT COLLINS, COLORADO THIS ____ DAY OF __________ A.□., 20. __ _ DIRECTOR OF COMMUNITY DEVELOPMENT AND NEIGHBORHOOD SERVICES PROJECT LOCATION Site Plan Notes: 1. REFER TO FINAL UTILITY PLANS FOR EXACT LOCATIONS AND CONSTRUCTION INFORMATION FOR STORM DRAINAGE STRUCTURES, UTILITY MAINS AND SERVICES, PROPOSED TOPOGRAPHY, SlREET IMPROVEMENTS. 2. REFER TO THE SUBDIVISION PLAT AND UTILITY PLANS FOR EXACT LOCATIONS, AREAS AND DIMENSIONS OF ALL EASEMENTS, LOTS, TRACTS, STREETS, WALKS AND OTHER SURVEY INFORMATION. 3. THE PROJECT SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE FINAL PLANS. AMENDMENTS TO THE PLANS MUST BE REVIEWED AND APPROVED BY THE CITY PRIOR TO THE IMPLEMENTATION OF ANY CHANGES TO THE PLANS . 4. ALL ROOFTOP AND GROUND MOUNTED MECHANICAL EQUIPMENT MUST BE SCREENED FROM VIEW FROM ADJACENT PROPERTY AND PUBLIC STREETS. IN CASES WHERE BUILDING PARAPETS DO NOT ACCOMPLISH SUFFICIENT SCREENING, THEN FREE-STANDING SCREEN WALLS MATCHING THE PREDOMINANT COLOR OF THE BUILDING SHALL BE CONSTRUCTED. OTHER MINOR EQUIPMENT SUCH AS CONDUIT, METERS AND PLUMBING VENTS SHALL BE SCREENED OR PAINTED TO MATCH SURROUNDING BUILDING SURFACES. 5. ALL CONSTRUCTION WITH THIS DEVELOPMENT PLAN MUST BE COMPLETED IN ONE PHASE UNLESS A PHASING PLAN IS SHOWN WITH THESE PLANS. 6. ALL EXTERIOR LIGHTING PROVIDED SHALL COMPLY WITH THE FOOT-CANDLE REQUIREMENTS IN SECTION 3.2.4 OF THE LAND USE CODE AND SHALL USE A CONCEALED, FULLY SHIELDED LIGHT SOURCE WITH SHARP CUT-OFF CAPABILITY SO AS TO MINIMIZE UP-LIGHT, SPILL LIGHT, GLARE AND UNNECESSARY DIFFUSION. 7. SIGNAGE AND ADDRESSING ARE NOT PERMITTED WITH THIS PLANNING DOCUMENT AND MUST BE APPROVED BY SEPARATE CITY PERMIT PRIOR TO CONSTRUCTION. SIGNS MUST COMPLY WITH CITY SIGN CODE UNLESS A SPECIFIC VARIANCE IS GRANTED BY TI-IE CllY. 8. FIRE HYDRANTS MUST MEET OR EXCEED POU DRE FIRE AUTHORITY STANDARDS. ALL BUILDINGS MUST PROVIDE AN APPROVED FIRE EXTINGUISHING SYSTEM. 9. ALL BIKE RACKS PROVIDED MUST BE PERMANENTLY ANCHORED. 10. ALL SIDEWALKS AND RAMPS MUST CONFORM TO CITY STANDARDS. ACCESSABLE RAMPS MUST BE PROVIDED AT ALL STREET AND DRIVE INTERSECTIONS AND AT ALL DESIGNATED ACCESSABLE PARKING SPACES. ACCESSABLE PARKING SPACES MUST SLOPE NO MORE THAN 1 :48 IN ANY DIRECTION. ALL ACCESSIBLE ROUlES MUST SLOPE NO MORE THAN 1:20 IN DIRECTION OF TRAVEL AND WITH NO MORE THAN 1:48 CROSS SLOPE. 11. COMMON OPEN SPACE AREAS AND LANDSCAPING WITHIN RIGHT OF WAYS, STREET MEDIANS, AND TRAFFIC CIRCLES ADJACENT TO COMMON OPEN SPACE AREAS ARE REQUIRED TO BE MAINTAINED BY THE PROPERTY OWNER OF THE COMMON AREA. THE PROPERTY OWNER IS RESPONSIBLE FOR SNOW REMOVAL ON ALL ADJACENT STREET SIDEWALKS AND SIDEWALKS IN COMMON OPEN SPACE AREAS. 12. DESIGN AND INSTALLATION OF ALL PARKWAY/TREE LAWN AND MEDIAN AREAS IN THE RIGHT-OF-WAY SHALL BE IN ACCORDANCE WITH CITY STANDARDS. UNLESS OTHERWISE AGREED TO BY THE CITY WITH THE FINAL PLANS, ALL ONGOING MAINTENANCE OF SUCH AREAS IS THE RESPONSIBILITY OF THE OWNER/DEVELOPER. 13. THE PROPERTY OWNER FOR EACH RESIDENTIAL LOT IS RESPONSIBLE FOR SNOW REMOVAL ON ALL STREET SIDEWALKS ADJACENT TO EACH RESIDENTIAL LOT. 14. PRIVATE CONDITIONS, COVENANTS, AND RESTRICTIONS (CC&R'S), OR ANY OTHER PRIVATE RESTRICTIVE COVENANT IMPOSED ON LANDOWNERS WITHIN THE DEVELOPMENT, MAY NOT BE CREATED OR ENFORCED HAVING THE EFFECT OF PROHIBITING OR LIMITING THE INSTALLATION OF XERISCAPE LANDSCAPING, SOLAR/PHOTO-VOLTAIC COLLECTORS (IF MOUNTED FLUSH UPON ANY ESTABLISHED ROOF LINE), CLOTI-lES LINES (IF LOCATED IN BACK YARDS), ODOR-CONTROLLED COMPOST BINS, OR WHICH HAVE THE EFFECT OF REQUIRING THAT A PORTION OF ANY INDIVIDUAL LOT BE PLANTED IN TURF GRASS. 15. ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. 16. FIRE LANE MARKING: A FIRE LANE MARKING PLAN MUST BE REVIEWED AND APPROVED BY THE FIRE OFFICIAL PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. WHERE REQUIRED BY THE FIRE CODE OFFICIAL, APPROVED SIGNS OR OTHER APPROVED NOTICES THAT INCLUDE THE WORDS NO PARKING FIRE LANE SHALL BE PROVIDED FOR FIRE APPARATUS ACCESS ROADS TO IDENTIFY SUCH ROADS OR PROHIBIT THE OBSTRUCTION THEREOF. THE MEANS BY WHICH FIRE LANES ARE DESIGNATED SHALL BE MAINTAINED IN A CLEAN AND LEGIBLE CONDITION AT ALL TIMES AD BE REPLACED OR REPAIRED WHEN NECESSARY TO PROVIDE ADEQUATE VISIBILITY. 17. PREMISE IDENTIFICATION: AN ADDRESSING PLAN IS REQUIRED TO BE REVIEWED AND APPROVED BY THE CITY AND POU DRE FIRE AUTHORITY PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. UNLESS THE PRIVATE DRIVE IS NAMED, MONUMENT SIGNAGE MAY BE REQUIRED TO ALLOW WAY FINDING. ALL BUILDINGS SHALL HAVE ADDRESS NUMBERS, BUILDING NUMBERS OR APPROVED BUILDING IDENTIFICATION PLACED IN A POSITION THAT IS PLAINLY LEGIBLE, VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY, AND POSTED WITH A MINIMUM OF SIX_INCH NUMERALS ON A CONTRASTING BACKGROUND. WHERE ACCESS IS BY MEANS OF A PRIVATE ROAD AND THE BUILDING CANNOT BE VIEWED FROM THE PUBLIC WAY, A MONUMENT, POLE OR OTHER SIGN OR MEANS SHALL BE USED TO IDENTIFY THE STRUCTURE. Sheet Index: COVERSHEET SITE PLAN NEIGHBORHOOD CONTEXT PLAN LANDSCAPE PLAN & TREE INVENTORY EXTERIOR ELEVATIONS PHOTOMETRIC 1 2 3 L-1 A2.1 P1.0 ~GROUP endscape arch lecture I rJannirg I illustration 444 Mountain Ave. m. 970.532.5891 Berth::ud,CO 80513 W"EB TBGroup.us PROJECT TITLE Bank of Colorado 1305 W. Elizabeth Street Fort Collins, CO 80521 PREPARED FOR OWNER: BANK OF COLORADO 1609 E. Harmony Road Fort Collins, CO 80525 REVIS IONS DATE DATE March 30, 2021 SHEET TITLE Cover Sheet SHEET INFORMATION Sheet Number: 1 Of: 5 EXISTINGSHRUBS (2)TO REMAINELIZABETH STREETNEW 5' WALK5' WALK CONNECTIONADJACENT PROPERTYNOT A PARTADJACENTPROPERTYNOT A PARTADJACENTLANDSCAPING - NOT A PARTNEW LANDSCAPEISLANDEXISTINGSIDEWALKDRIVE-THRULANES - TYP.WALLEXISTING TRASHENCLOSUREDECIDUOUS SHRUBSQTYBOTANICAL / COMMON NAMESIZEHEIGHTWIDTHREMARKS9Caryopteris x clandonensis `Blue Mist`5 gal.4`4`24" (h) FULL SPECIMEN EVENLYBlue Mist SpireaAND WELL BRANCHED2Cornus sericea `Isanti`5 gal.5`5`24" (h) FULL SPECIMEN EVENLYIsanti Red Twig DogwoodAND WELL BRANCHED9Physocarpus opulifolius `Summer Wine`5 gal.4`4`24" (h) FULL SPECIMEN EVENLYSummer Wine NinebarkAND WELL BRANCHEDEVERGREEN SHRUBSQTYBOTANICAL / COMMON NAMESIZEHEIGHTWIDTHREMARKS4Arctostaphylos uva-ursi5 gal.6"6`12"(h) FULL SPECIMEN, EVENLYKinnikinnickAND WELL BRANCHED2Juniperus horizontalis `Blue Chip`5 gal.1.5`5`12"(h) FULL SPECIMEN, EVENLYBlue Chip JuniperAND WELL BRANCHEDGRASSESQTYBOTANICAL / COMMON NAMESIZEHEIGHTWIDTHREMARKS22Bouteloua gracilis `Blonde Ambition`1 gal.2`2`WELL ROOTED AND ESTABLISHEDBlonde Ambition Grama Grass11Calamagrostis x acutiflora `Karl Foerster`1 gal.5`2`WELL ROOTED AND ESTABLISHEDFeather Reed GrassPERENNIALSQTYBOTANICAL / COMMON NAMESIZEHEIGHTWIDTHREMARKS22Hemerocallis x `Stella de Oro`1 gal.2`2`WELL ROOTED AND ESTABLISHEDStella de Oro Daylily8Rudbeckia fulgida sullivantii `Goldsturm`1 gal.2`2`WELL ROOTED AND ESTABLISHEDBlack-eyed SusanSYMBOLDESCRIPTIONQTY1.5" - 3" WASHED RIVER ROCK COBBLE2,187 sfALL SHRUB BEDS TO RECEIVE AMINIMUM 3" DEPTHCOLOR BY DEVELOPERTHAN FINISH GRADE / IRRIGATION TREE WELL TO BE PROVIDEDOPEN BURLAP AROUND TRUNK.CUT & REMOVE TOP 1/3 OF BURLAPGROUND COVER & SHRUB PLANTING DETAILBACKFILL W/ 2/3 NATIVE SOIL& 1/3 COMPOST. THOROUGHLYWATER SETTLESLOW RELEASE FERTILIZER TABLET (TYP.)3" MIN.2"AWAY FROM FOLIAGESECTIONEXISTINGSOILFOR SHRUBSTHAN DIA. OFTO BE 6" LARGERPLANTING HOLEROOTBALL FORDIA. OF ROOTBALL12" LARGER THANGROUNDCOVER.KEEP MULCH LAYERFINISH GRADETOP OF ROOT CROWN TO BE 1" HIGHER THAN FINISHGRADE/IRRIGATION SHRUB WELL TO BE PROVIDED FOR ALLSHRUBS WITHIN THE BUFFER ENHANCEMENT ZONECEDAR MULCH RING TO BE TWICEDIAMETER OF ROOT BALL - 2" DEPTHMULCH - SEE NOTES - 5" DEPTHMAXIMUMTRUNKTREE3" MULCH12" MIN.SECTION12" MIN.,TYP.NOTE:CEDAR MULCHTREE RING SHALLBE 36" DIA.BACKFILL W/ 2/3 NATIVE SOIL & 1/3COMPOST. THOROUGHLY WATERSETTLETIE GROMMETED NYLON STRAPS TO STAKE WITH WIRE. WIREENDS SHALL BE BENT BACK TO ELIMINATE BURRS AND WHITE PVCPIPE ALONG ENTIRE LENGTH OF WIRE FOR VISUAL AND SAFETYTOP OF ROOT CROWN TO BE 1" HIGHEREXISTING SOILSLOW RELEASE FERTILIZER TABLET (TYP.)DRIVE TWO (2) WOOD STAKES PERTREE.REMOVE WIRE CAGE AND/OR TWINE. OPEN BURLAPAROUND TRUNK. CUT & REMOVE TOP 1/3 OF BURLAPPLANTHAN DIA. OF24" GREATERROOTBALLFINISH GRADET-POSTTREE TRUNKWIRE, TYP.NOTE: THE WIRE BETWEEN THE STAKEAND THE TREE MUST HAVE SLACK5' MIN.GROMMETED NYLON STRAP, TYP.NOTE:WIRE BASKETS AND TWINE SHALL BE COMPLETELYREMOVED PRIOR TO TREE INSTALLATION.THAN FINISH GRADE / IRRIGATION TREE WELL TO BE PROVIDEDTOP OF ROOT CROWN TO BE 1" HIGHERDRIVE THREE (3) WOOD STAKES PERTREE FOR TREES OVER 6' IN HEIGHT.DRIVE TWO (2) WOOD STAKES FORTREES 6' IN HEIGHT OR LESS. SPACEANCHORS EQUALLY AROUND TRUNK.AVOID DAMAGE TO BRANCHES.EXISTING SOILSLOW RELEASE FERTILIZER TABLET (TYP.)BACKFILL W/ 2/3 NATIVE SOIL & 1/3COMPOST. THOROUGHLY WATERSETTLEREMOVE WIRE CAGE AND/OR TWINE. OPEN BURLAPAROUND TRUNK. CUT & REMOVE TOP 1/3 OF BURLAP18" MIN.,TYP.SECTION12" MIN.ROOTBALLTHAN DIA. OF24" GREATERFINISH GRADEPLANTREE TRUNKT-POSTGROMMETED NYLON STRAP, TYP.WIRE, TYP.NOTE: THE WIRE BETWEEN THE STAKEAND THE TREE MUST HAVE SLACKTOP OF ROOT CROWN TOBE 1" HIGHER THANFINISH GRADENOTE:WIRE BASKETS AND TWINE SHALL BE COMPLETELYREMOVED PRIOR TO TREE INSTALLATION.DECIDUOUS TREE PLANTING DETAILCONIFER TREE PLANTING DETAILNOTE:CEDAR MULCH TREERING SHALL BE 36" DIA.3" MULCHROOTBALL DEPTH ROOTBALL DEPTH ROOTBALL DEPTH TIE GROMMETED NYLON STRAPS TO STAKE WITH WIRE. WIREENDS SHALL BE BENT BACK TO ELIMINATE BURRS AND WHITE PVCPIPE ALONG ENTIRE LENGTH OF WIRE FOR VISUAL AND SAFETYFOR ALL TREES WITHIN THE BUFFER ENHANCEMENT ZONEFOR ALL TREES WITHIN THE BUFFER ENHANCEMENT ZONELandscape Plan & Tree InventoryOf:Sheet Number:Fort Collins, CO 80521BANK OFCOLORADOGROUPlandscape ar chitecture|planning|illustr ation444 Mountain Ave.Berthoud,CO 80513T(/:(B970.532.5891TBGr oup.usPROJECT TITLEREVISIONSISSUE DATESHEET TITLESHEET INFORMATIONDATESEALMarch 30, 2021DATEPREPARED FOR1305 W. Elizabeth StreetBank of Colorado5Fort Collins, CO 805251609 E. Harmony RoadOWNER:Landscape Plan &Tree InventoryPlant PaletteSCALE 1" = 10'-0"10'020'15'NORTHExisting Tree ScheduleCOMMON NAMESIZE CONDITIONTO BE REMOVED MITIGATION REQUIREDREASON FOR REMOVAL1. COTTONWOOD 30"FAIR NO 3.5---2. GREEN ASH8"FAIR PLUSYES 1 RISK OF EMERALD ASH BORER3. GREEN ASH12"FAIR PLUSYES 2 RISK OF EMERALD ASH BORERTOTAL MITIGATION REQUIRED3 MITIGATION TREES#1: COTTONWOOD TREE TOREMAINSIZE:30"CONDITION: FAIRMITIGATION REQ'D: 3.5#2: GREEN ASH TREE TO BEREMOVEDSIZE: 8"CONDITION: FAIR PLUSMITIGATION REQ'D: 1Materials LegendHydrozone TableZONE AREAWATER USEGALLONSHIGH0 SF18 GAL/SF0 GALMODERATE1,093 SF10 GAL/SF10,930 GALLOW1,094 SF3 GAL/SF 3,282 GALVERY LOW0 SF0 GAL/SF0 GALTOTAL / AVERAGE2,187 SF14,212 GAL 6.50 GAL/SFPROPOSEDBUILDINGLS1A PERMIT MUST BE OBTAINED FROM THE CITY FORESTER BEFORE ANYTREES OR SHRUBS AS NOTED ON THIS PLAN ARE PLANTED, PRUNEDOR REMOVED IN THE PUBLIC RIGHT-OF-WAY. THIS INCLUDES ZONESBETWEEN THE SIDEWALK AND CURB, MEDIANS AND OTHER CITYPROPERTY. THIS PERMIT SHALL APPROVE THE LOCATION ANDSPECIES TO BE PLANTED. FAILURE TO OBTAIN THIS PERMIT IS AVIOLATION OF THE CITY OF FORT COLLINS CODE SUBJECT TOCITATION (SECTION 27-31) AND MAY ALSO RESULT IN REPLACING ORRELOCATING TREES AND A HOLD ON CERTIFICATE OF OCCUPANCY.Planting Details1.PLANT QUALITY: ALL PLANT MATERIAL SHALL BE A-GRADE OR NO. 1 GRADE - FREE OF ANY DEFECTS, OF NORMALHEALTH, HEIGHT, LEAF DENSITY AND SPREAD APPROPRIATE TO THE SPECIES AS DEFINED BY THE AMERICANASSOCIATION OF NURSERYMEN (AAN) STANDARDS. ALL TREES SHALL BE BALL AND BURLAP OR EQUIVALENT.2.IRRIGATION: ALL LANDSCAPE AREAS WITHIN THE SITE INCLUDING TURF, SHRUB BEDS AND TREE AREAS SHALL BEIRRIGATED WITH AN AUTOMATIC IRRIGATION SYSTEM. THE IRRIGATION PLAN MUST BE REVIEWED AND APPROVED BYTHE CITY OF FORT COLLINS WATER UTILITIES DEPARTMENT PRIOR TO THE ISSUANCE OF A BUILDING PERMIT. ALLTURF AREAS SHALL BE IRRIGATED WITH AN AUTOMATIC POP-UP IRRIGATION SYSTEM. ALL SHRUB BEDS AND TREES,INCLUDING IN NATIVE SEED AREAS, SHALL BE IRRIGATED WITH AN AUTOMATIC DRIP (TRICKLE) IRRIGATION SYSTEM, ORWITH AN ACCEPTABLE ALTERNATIVE APPROVED BY THE CITY WITH THE IRRIGATION PLANS. THE IRRIGATION SYSTEMSHALL BE ADJUSTED TO MEET THE WATER REQUIREMENTS OF THE INDIVIDUAL PLANT MATERIAL.3.TOPSOIL: TO THE MAXIMUM EXTENT FEASIBLE, TOPSOIL THAT IS REMOVED DURING CONSTRUCTION ACTIVITY SHALL BECONSERVED FOR LATER USE ON AREAS REQUIRING REVEGETATION AND LANDSCAPING.4.SOIL AMENDMENTS: SOIL AMENDMENTS SHALL BE PROVIDED AND DOCUMENTED IN ACCORDANCE WITH CITY CODESECTION 12-132. THE SOIL IN ALL LANDSCAPE AREAS, INCLUDING PARKWAYS AND MEDIANS, SHALL BE THOROUGHLYLOOSENED TO A DEPTH OF NOT LESS THAN EIGHT(8) INCHES AND SOIL AMENDMENT SHALL BE THOROUGHLYINCORPORATED INTO THE SOIL OF ALL LANDSCAPE AREAS TO A DEPTH OF AT LEAST SIX(6) INCHES BY TILLING, DISCINGOR OTHER SUITABLE METHOD, AT A RATE OF AT LEAST THREE (3) CUBIC YARDS OF SOIL AMENDMENT PER ONETHOUSAND (1,000) SQUARE FEET OF LANDSCAPE AREA. PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OFOCCUPANCY, A WRITTEN CERTIFICATION MUST BE SUBMITTED TO THE CITY THAT ALL PLANTED AREAS, OR AREAS TOBE PLANTED, HAVE BEEN THOROUGHLY LOOSENED AND THE SOIL AMENDED, CONSISTENT WITH THE REQUIREMENTSSET FORTH IN SECTION 12-132.5.INSTALLATION AND GUARANTEE: ALL LANDSCAPING SHALL BE INSTALLED ACCORDING TO SOUND HORTICULTURALPRACTICES IN A MANNER DESIGNED TO ENCOURAGE QUICK ESTABLISHMENT AND HEALTHY GROWTH. ALLLANDSCAPING FOR EACH PHASE MUST BE EITHER INSTALLED OR THE INSTALLATION MUST BE SECURED WITH ANIRREVOCABLE LETTER OF CREDIT, PERFORMANCE BOND, OR ESCROW ACCOUNT FOR 125% OF THE VALUATION OF THEMATERIALS AND LABOR PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY FOR ANY BUILDING IN SUCH PHASE.6.MAINTENANCE: TREES AND VEGETATION, IRRIGATION SYSTEMS, FENCES, WALLS AND OTHER LANDSCAPE ELEMENTSWITH THESE FINAL PLANS SHALL BE CONSIDERED AS ELEMENTS OF THE PROJECT IN THE SAME MANNER AS PARKING,BUILDING MATERIALS AND OTHER SITE DETAILS. THE APPLICANT, LANDOWNER OR SUCCESSORS IN INTEREST SHALLBE JOINTLY AND SEVERALLY RESPONSIBLE FOR THE REGULAR MAINTENANCE OF ALL LANDSCAPING ELEMENTS INGOOD CONDITION. ALL LANDSCAPING SHALL BE MAINTAINED FREE FROM DISEASE, PESTS, WEEDS AND LITTER, ANDALL LANDSCAPE STRUCTURES SUCH AS FENCES AND WALLS SHALL BE REPAIRED AND REPLACED PERIODICALLY TOMAINTAIN A STRUCTURALLY SOUND CONDITION.7.REPLACEMENT: ANY LANDSCAPE ELEMENT THAT DIES, OR IS OTHERWISE REMOVED, SHALL BE PROMPTLY REPLACEDIN ACCORDANCE WITH THE REQUIREMENTS OF THESE PLANS.8.THE FOLLOWING SEPARATIONS SHALL BE PROVIDED BETWEEN TREES/SHRUBS AND UTILITIES:40 FEET BETWEEN CANOPY TREES AND STREET LIGHTS15 FEET BETWEEN ORNAMENTAL TREES AND STREETLIGHTS10 FEET BETWEEN TREES AND PUBLIC WATER, SANITARY AND STORM SEWER MAIN LINES6 FEET BETWEEN TREES AND PUBLIC WATER, SANITARY AND STORM SEWER SERVICE LINES.4 FEET BETWEEN SHRUBS AND PUBLIC WATER AND SANITARY AND STORM SEWER LINES4 FEET BETWEEN TREES AND GAS LINES9.ALL STREET TREES SHALL BE PLACED A MINIMUM EIGHT (8) FEET AWAY FROM THE EDGES OF DRIVEWAYS AND ALLEYSPER LUC 3.2.1(D)(2)(a).10.PLACEMENT OF ALL LANDSCAPING SHALL BE IN ACCORDANCE WITH THE SIGHT DISTANCE CRITERIA AS SPECIFIED BYTHE CITY OF FORT COLLINS. NO STRUCTURES OR LANDSCAPE ELEMENTS GREATER THAN 24" SHALL BE ALLOWEDWITHIN THE SIGHT DISTANCE TRIANGLE OR EASEMENTS WITH THE EXCEPTION OF DECIDUOUS TREES PROVIDED THATTHE LOWEST BRANCH IS AT LEAST 6' FROM GRADE. ANY FENCES WITHIN THE SIGHT DISTANCE TRIANGLE OREASEMENT MUST BE NOT MORE THAN 42" IN HEIGHT AND OF AN OPEN DESIGN.11.THE FINAL LANDSCAPE PLAN SHALL BE COORDINATED WITH ALL OTHER FINAL PLAN ELEMENTS SO THAT THEPROPOSED GRADING, STORM DRAINAGE, AND OTHER DEVELOPMENT IMPROVEMENTS DO NOT CONFLICT WITH NORPRECLUDE INSTALLATION AND MAINTENANCE OF LANDSCAPE ELEMENTS ON THIS PLAN.12.MINOR CHANGES IN SPECIES AND PLANT LOCATIONS MAY BE MADE DURING CONSTRUCTION -- AS REQUIRED BY SITECONDITIONS OR PLANT AVAILABILITY. OVERALL QUANTITY, QUALITY, AND DESIGN CONCEPT MUST BE CONSISTENTWITH THE APPROVED PLANS. IN THE EVENT OF CONFLICT WITH THE QUANTITIES INCLUDED IN THE PLANT LIST,SPECIES AND QUANTITIES ILLUSTRATED SHALL BE PROVIDED. ALL CHANGES OF PLANT SPECIES AND LOCATION MUSTHAVE WRITTEN APPROVAL BY THE CITY PRIOR TO INSTALLATION.13.ALL PLANTING BEDS SHALL BE MULCHED TO A MINIMUM DEPTH OF THREE INCHES.General Landscape Notes1.ALL EXISTING TREES WITHIN THE LIMITS OF THE DEVELOPMENT AND WITHIN ANY NATURAL AREA BUFFER ZONES SHALL REMAIN AND BEPROTECTED UNLESS NOTED ON THESE PLANS FOR REMOVAL.2.WITHIN THE DRIP LINE OF ANY PROTECTED EXISTING TREE, THERE SHALL BE NO CUT OR FILL OVER A FOUR-INCH DEPTH UNLESS AQUALIFIED ARBORIST OR FORESTER HAS EVALUATED AND APPROVED THE DISTURBANCE.3.ALL PROTECTED EXISTING TREES SHALL BE PRUNED TO THE CITY OF FORT COLLINS FORESTRY STANDARDS. TREE PRUNING AND REMOVALSHALL BE PERFORMED BY A BUSINESS THAT HOLDS A CURRENT CITY OF FORT COLLINS ARBORIST LICENSE WHERE REQUIRED BY CODE.4.PRIOR TO AND DURING CONSTRUCTION, BARRIERS SHALL BE ERECTED AROUND ALL PROTECTED EXISTING TREES WITH SUCH BARRIERSTO BE OF ORANGE FENCING A MINIMUM OF FOUR (4) FEET IN HEIGHT, SECURED WITH METAL T-POSTS, NO CLOSER THAN SIX (6) FEET FROMTHE TRUNK OR ONE-HALF (½) OF THE DRIP LINE, WHICHEVER IS GREATER. THERE SHALL BE NO STORAGE OR MOVEMENT OF EQUIPMENT,MATERIAL, DEBRIS OR FILL WITHIN THE FENCED TREE PROTECTION ZONE.5.DURING THE CONSTRUCTION STAGE OF DEVELOPMENT, THE APPLICANT SHALL PREVENT THE CLEANING OF EQUIPMENT OR MATERIAL ORTHE STORAGE AND DISPOSAL OF WASTE MATERIAL SUCH AS PAINTS, OILS, SOLVENTS, ASPHALT, CONCRETE, MOTOR OIL OR ANY OTHERMATERIAL HARMFUL TO THE LIFE OF A TREE WITHIN THE DRIP LINE OF ANY PROTECTED TREE OR GROUP OF TREES.6.NO DAMAGING ATTACHMENT, WIRES, SIGNS OR PERMITS MAY BE FASTENED TO ANY PROTECTED TREE.7.LARGE PROPERTY AREAS CONTAINING PROTECTED TREES AND SEPARATED FROM CONSTRUCTION OR LAND CLEARING AREAS, ROADRIGHTS-OF-WAY AND UTILITY EASEMENTS MAY BE "RIBBONED OFF," RATHER THAN ERECTING PROTECTIVE FENCING AROUND EACH TREEAS REQUIRED IN SUBSECTION (G)(3) ABOVE. THIS MAY BE ACCOMPLISHED BY PLACING METAL T-POST STAKES A MAXIMUM OF FIFTY (50)FEET APART AND TYING RIBBON OR ROPE FROM STAKE-TO-STAKE ALONG THE OUTSIDE PERIMETERS OF SUCH AREAS BEING CLEARED.8.THE INSTALLATION OF UTILITIES, IRRIGATION LINES OR ANY UNDERGROUND FIXTURE REQUIRING EXCAVATION DEEPER THAN SIX (6) INCHESSHALL BE ACCOMPLISHED BY BORING UNDER THE ROOT SYSTEM OF PROTECTED EXISTING TREES AT A MINIMUM DEPTH OF TWENTY-FOUR(24) INCHES. THE AUGER DISTANCE IS ESTABLISHED FROM THE FACE OF THE TREE (OUTER BARK) AND IS SCALED FROM TREE DIAMETER ATBREAST HEIGHT AS DESCRIBED IN THE CHART BELOW:TREE DIAMETER AT BREAST HEIGHT (INCHES)AUGER DISTANCE FROM FACE OF TREE (FEET)0-213-425-9510-141015-1912OVER 19159.“NO TREES SHALL BE REMOVED DURING THE SONGBIRD NESTING SEASON (FEBRUARY 1 TO JULY 31) WITHOUT FIRST HAVING APROFESSIONAL ECOLOGIST OR WILDLIFE BIOLOGIST COMPLETE A NESTING SURVEY TO IDENTIFY ANY ACTIVE NESTS EXISTING ON THEPROJECT SITE. THE SURVEY SHALL BE SENT TO THE CITY ENVIRONMENTAL PLANNER. IF ACTIVE NESTS ARE FOUND, THE CITY WILLCOORDINATE WITH RELEVANT STATE ANDFEDERAL REPRESENTATIVES TO DETERMINE WHETHER ADDITIONAL RESTRICTIONS ON TREE REMOVAL AND CONSTRUCTION APPLY.”Tree Protection Notes#3:GREEN ASH TREE TOBE REMOVEDSIZE: 12"CONDITION: FAIR PLUSMITIGATION REQ'D: 2 02 -New Floor Plan 100' -0" Parapet 115' -8" W1 W2 R1 C1 C1 C1 C2 C12 C7 C4 C4C4C4 C6 C6C6 C5 02 -New Floor Plan 100' -0" Parapet 115' -8" C9 C4 C4 C6 C4 W2 W1 R1 C6 C7 C13 C10C10 C8 C8 C6 W1 R1 C4C4 C4 C5 C6 C9 C10 C1 C1C1 C11 C11 W2 R1 C5 C6 C6C4C4 C10 C9 C3 C13C7C7 C1 W1 Modular Brick -4" Veneer Manuf: General Shale Product: Modular Brick, running bond + soldier Field Color: Coffeebean Soldier Course: Imperial 41 G Horizontal Cementitious Lap Siding -5" Exposure Manuf: James Hardie Product: HardiePlank, Smooth Finish Lap Siding Color: Universal Khaki -SW6150 Standing Seam Metal Roof Manuf: Berridge Product: Prefinished "Cee-lock" standing seam metal Color: Champagne E X T E R I O R M A T E R I A L S W1 W2 R1 C14C14 C14 Issued Drawing Number Scale Accordingly if Reduced Project No.:Drawn by: Reviewed by: In Association with:ARCHITECTSarchitects.comr4 226 Remington Unit #3 Fort Collins, CO 80524 phone 970/224-0630 www.r4architects.com Contact: Nick Decker Email: ndecker@rakerrhodes.com Raker Rhodes Phone: (970) 493-1391 Fort Collins, CO 80524 236 Linden Street, Suite A Structural Engineer Contact: Tom Segelhorst Email: Thomas-s@int-mech.com Integrated Mechanical Phone: (970)556-0570 Fort Collins, CO 80521 320 Maple St. #110 M/P Engineer Contact: Larry Smith Email: Larry@electricon-eng.com Electricon Phone: (970) 686-1004 Loveland, CO 80537 546 8th St. SE Building A, Unit 4 Electrical Engineer Contact: Cathy Mathis & Jim Doyle Email: cathy@tbgroup.us, doyle@tbgroup.us TB Group Phone: (970)532-5891 Berthoud, CO 80531 444 Mountain Avenue Planning & Landscape Contact: Mike Oberlander Email: moberlander@Interwestgrp.com Interwest Consulting Group Phone: (970)674-3300 Windsor, CO 80550 1218 Ash Street Civil Engineer Contact: Cody Fullmer Email: cody.fullmer@bankofcolorado.com Bank of Colorado Phone: 970-266-1169 Fort Collins, CO 80525 1609 E Harmony Road Owner Contact: - Email: - TBD Phone: # City, State, Zip Address General Contractor Contact: Annie Lilyblade Email: annie.lilyblade@saltdesign.co SALT Design Phone: 303.710.1604 Fort Collins, CO 80524 824 Colorado St Interior Design MR MR A2.1 Exterior Elevations PDP/FDP Submittal 2020-13 Bank of Colorado 1311 W Elizabeth 1/8" = 1'-0"1 North Building Elevation 1/8" = 1'-0"2 South Building Elevation 1/8" = 1'-0"3 East Building Elevation 1/8" = 1'-0"4 West Building Elevation Keynote Legend Key Value Keynote Text C1 Storefront windows, prefinished, color: Medium Bronze C2 Storefront entry door, prefinished, color: Medium Bronze C3 Security drive up window, prefinished, color: Medium Bronze C4 Gutters, scuppers, collection heads, and downspouts to be feild painted to match standing seam roof. C5 Steel canopy, factory primed, field painted, see detail x/Ax.x C6 Prefinished cap flashing, Manuf: Berridge. color: Champagne C7 Steel pipe bollard, see detail x/Ax.x C8 Insulated Hollow Metal door, factory primed and field painted, color: Medium Bronze C9 Gas Meter C10 Electrical equipment and meter C11 Precast window sill C12 Building signage per separate permit C13 ATM, by owner C14 Existing wood trash enclosure to be power washed, cleaned, and stained. Color to match new brick color. All exposed to steel to be feild primed. Existing wood planks to be replaced as needed. Maintain existing gate and service hindges and closure. 1/4" = 1'-0"5 Trash Enclosure North Elevation 1/4" = 1'-0"10 Trash Enclosure West Elevation 1/4" = 1'-0"11 Trash Enclosure East Elevation No. Description Date 3 PDP/ FDP Submittal 1 3.25.2021 0.0 0.1 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.3 0.2 0.2 0.1 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 3.3 2.4 2.1 1.0 5.4 4.1 9.9 0.6 0.2 0.4 0.6 1.4 2.3 3.2 0.1 0.0 0.0 0.0 2.5 1.9 1.6 0.8 4.4 3.3 8.3 0.5 0.2 0.4 0.6 1.3 1.8 2.4 0.2 0.1 0.1 0.0 1.6 1.3 1.1 0.9 7.5 4.7 0.8 0.3 0.5 0.6 1.0 1.5 2.1 0.4 0.2 0.1 0.0 0.8 0.8 1.0 2.5 1.7 1.6 0.8 0.7 0.8 1.1 0.4 0.2 0.1 0.1 0.4 0.5 0.8 3.8 3.7 0.8 0.4 0.3 0.4 0.3 0.1 0.1 0.1 0.1 0.2 0.3 0.4 1.0 0.8 0.0 0.0 0.0 1.5 1.3 0.4 0.2 0.1 0.2 0.1 0.0 0.1 0.1 0.0 0.1 0.1 0.2 0.2 0.2 0.0 0.0 0.1 0.2 0.3 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 Issued Drawing Number Scale Accordingly if Reduced Project No.:Drawn by: Reviewed by: In Association with:ARCHITECTSarchitects.comr4 226 Remington Unit #3 Fort Collins, CO 80524 phone 970/224-0630 www.r4architects.com Contact: Chuck Polson Email: chuck@apsinc.biz APS, Inc. Phone: (970) 381-7462 Timnath, CO 80547 3135 Laminar Court Electrical Engineer CP2 CP APS 205-21 Colorado Bank of Elizabeth No.Description Date 1 Photometric 03/20/2021 P1.0 PHOTOMETRIC REQUIRES REVIEW AND APPROVAL BY STRUCTURAL ENGINEER Statistics Description Symbol Avg Max Min Max/Min Avg/Min Calc Zone #1 0.8 fc 9.9 fc 0.0 fc N/A N/A Schedule Symbol Label Quantity Manufactur er Catalog Number Description Lamp Number Lamps Filename Lumens Per Lamp Light Loss Factor Wattage AA- LCO 2 Lithonia Lighting DSX0 LED P2 30K LCCO MVOLT DSX0 LED P2 30K LCCO MVOLT LED 1 DSX0_LED_P 2_30K_LCCO _MVOLT.ies 3402 1 49 AA- RCO 0 Lithonia Lighting DSX0 LED P2 30K RCCO MVOLT DSX0 LED P2 30K RCCO MVOLT LED 1 DSX0_LED_P 2_30K_RCC O_MVOLT.ies 3402 1 49 BB 2 Lithonia Lighting WST LED P1 30K VF MVOLT WST LED, Performance package 1, 3000 K, visual comfort forward throw, MVOLT LED 1 WST_LED_P 1_30K_VF_M VOLT.ies 1529 1 12 CC 4 Lithonia Lighting LDN6 30/20 LO6AR LD 6IN LDN, 3000K, 2000LM, 80CRI, CLEAR, MATTE DIFFUSE REFLECTOR LED 1 LDN6_30_20 _LO6AR_LD.i es 1662 1 22.61 Luminaire Locations No.Label X Y Z Location MH Orientation Tilt X Y Aim Z 1 AA-LCO 34.37 38.66 20.00 20.00 0.00 0.00 34.37 39.74 0.00 2 AA-LCO 35.47 174.06 20.00 20.00 90.58 0.00 36.55 174.05 0.00 1 BB 75.90 119.96 9.00 9.00 0.00 0.00 75.90 120.27 0.00 2 BB 73.80 80.15 9.00 9.00 180.66 0.00 73.80 79.84 0.00 1 CC 40.55 101.15 10.00 10.00 0.00 0.00 40.55 101.15 0.00 2 CC 39.96 85.07 10.00 10.00 0.00 0.00 39.96 85.07 0.00 3 CC 53.85 100.85 10.00 10.00 0.00 0.00 53.85 100.85 0.00 4 CC 53.26 84.77 10.00 10.00 0.00 0.00 53.26 84.77 0.00