Loading...
HomeMy WebLinkAboutKS146 TYP. NEW STORE SINGLE LINE_UpdatedST M EM EM EM UT EM MGC M.C.B.M.L.O. M.L.O.M.L.O.M.L.O. M.L.O. M.L.O. 225A M.C.B. M.L.O. M.L.O. M.L.O. 225A M.L.O. M.L.O. 225A M.L.O. 125A M.L.OM.L.O 1600A/3P 500 kVA 400A 400A 225A225A225A 100% RATED 225A 100A 200A 480/277V, 3 PHASE, 4-WIRE 50A100A/3P600A BATTERY CHARGERS 225A 200 200 75 kVA 225A800A/3P225A 2500A/3P COMPACTOR SHUNTTRIPSHUNTTRIPSHUNT TRIP 400A 30 100kW/125kVA 480/277V, 3 PHASE, 4-WIRE LSIGLSIG 400A 225A225A GFCI PROTECTED #8 CU #6 CU #6 CU #2 CU #1/0 CU #1/0 CU #2 /0 CU #3/0 CU #3/0 CU #3/0 CU #3/0 CU #3/0 CU 15 30 45 75 112.5 150 200 225 300 400 500 750 GROUND WIRE SIZEKVA TRANSFORMER GROUNDING MAIN BREAKER KIRK KEY INTERLOCK KIRK KEY BREAKER FOR FULL-STORE BACK-UP 1600A/3P GFCI PROTECTED TYPICAL FOR ALL OWNER FURNISHED ELECTRICAL EQUIPMENT (DIRECT BUY) TYPICAL FOR ALL OWNER FURNISHED ELECTRICAL EQUIPMENT (DIRECT BUY) NEMA 3R BUSSED ENCLOSURE WITH QUICK CONNECT RECEPTACLES IN AND LUGS / CABLE OUT FURNISHED BY KROGER. EXTERIOR MOUNTED FOR TEMPORARY CONNECTION OF MOBILE GENERATOR. CONCRETE PAD GROUND MAT 1500 KVA SECONDARY VOLTAGE-480/277V 3∅/4-WIRE TLDPA TRANSFORMER 480V TO 208Y/120V LJLH LD1FLA2FLA1 8 GROUND PER N.E.C. ELEC. CONTRACTOR SHALL RECEIVE & INSTALL G.E. #TCAL LUG KIT, WHICH SHALL BE FURNISHED BY G.E. HA ATS1 EHA ATS2 ELA EMERGENCY ESSENTIAL POWERAUTOMATIC TRANSFER SWITCHELB MAIN SWITCHBOARD "MSB" EMERGENC Y OPTIONAL STANDBY (NEC 700.5(B)) POWER AUTOMATIC TRANSFER SWITCH ELECTRICAL SINGLE-LINE DIAGRAM 42 10 11 J.B. AT KIOSK 9 12 EXOTHERMIC WELD (TYPICAL) 3/4" DIA x 10FT. GROUND ROD (MINIMUM 3 PER SPECIFICATION) OPTIONAL STANDBY "CLEAN" POWER NOTE: PROVIDE DEDICATED INSULATED ISOLATED GROUND CONDUCTOR FROM THE SERVICE ENTRANCE DERIVED GROUND TO THE INSULATED ISOLATED GROUND BAR IN THE PANEL "ELA", "ELB", AND "ELP" (WITH NO BREAKS, BONDING, SPLICES, ETC. BETWEEN THE TWO). IN ADDITION PROVIDE GROUNDING ELECTRODE CONDUCTOR AT "TELA" AND EQUIPMENT GROUNDING CONDUCTOR FROM "TELA" TO BONDED EUIPMENT GROUND BAR IN PANELS "ELA", "ELB", "ELC", AND "ELP". PPA1 M.L.O.(ST1-480S)5.3A (ST1-480S)LC 5.3A MAIN DISTRIBUTION PANEL "LDPA" 208/120V, 3 PHASE, 4-WIRE 3Φ/4-WIRE TELA TRANSFORMER 480V TO 208Y/120V GROUND PER N.E.C. EHB DELA 5 ELC FLUSH OPTIONAL STANDBY "DIRTY" POWER OPTIONAL STANDBY "CLEAN" POWER 1 LF1 3 13 14 21 22 26 LEHA1 TO LIGHTING LOADS6 GROUND PER N.E.C. ELP FLUSH (PHARMACY) COFFEE KIOSK PANEL NEMA 1 NEMA 1 NEMA 1 NEMA 1 SECONDARY TRANSFORMER CONDUCTOR LENGTH NOT TO EXCEED 10'-0" NEMA 3R NEMA 1 FLUSHFLUSH PPA2 M.L.O.TO LIGHTING LOADSPANEL LF1 CU-1 PANEL ELB BUILDING STEEL & REBARS INCOMING WATER SERVICE A SIGN SHALL BE PLACED AT THE SERVICE ENTRANCE EQUIPMENT THAT INDICATES THE TYPE AND LOCATION OF ON-SITE EMERGENCY POWER SOURCES. A SIGN SHALL BE PLACED AT THE SERVICE ENTRANCE EQUIPMENT THAT INDICATES THE TYPE AND LOCATION OF ON-SITE EMERGENCY POWER SOURCES. (SPECIALTY LTG) SPACES AS AVAILABLE SINGLE-LINE LEGEND PROVIDED (FURNISHED AND INSTALLED) BY ELECTRICAL CONTRACTOR. FLUSH INDICATES EQUIPMENT FURNISHED BY EQUIPMENT MANUFACTURER AND RECEIVED / INSTALLED / WIRED BY ELECTRICAL CONTRACTOR (UNLESS NOTED OTHERWISE). INDICATES EQUIPMENT FURNISHED BY KROGER AS PART OF DIRECT BUY G.E. ELECTRICAL EQUIPMENT PACKAGE AND RECEIVED / INSTALLED / WIRED BY ELECTRICAL CONTRACTOR. INDICATES PANELBOARD THAT WILL BE FURNISHED WITH SUB-FEED LUGS KIT THAT SHALL BE INSTALLED BY ELECTRICAL CONTRACTOR. INDICATES FLUSH MOUNTED PANELBOARD. ALL OTHER PANELBOARDS SHALL BE SURFACE MOUNTED. INDICATES EQUIPMENT FURNISHED BY ELECTRICAL UTILITY, INSTALLATION ASSISTED BY ELECTRICAL CONTRACTOR (UNLESS NOTED OTHERWISE). SURGE PROTECTION AS REQUIRED PER NEC 700.8. EMERGENCY GENERATOR NATURAL GAS, STANDBY RATED WIREWAY NEMA 3R IN 1" CONDUIT, CONNECT FROM OUTPUT TERMINALS TO BUILDING SECURITY SYSTEM FOR FAULT CONDITION. SEE DETAIL ESD-3B.2 ON E5-SERIES DRAWINGS FOR EMERGENCY SYSTEM WIRING DIAGRAM. SEE PNET SCHEDULE FOR GENERATOR ORDERING INFORMATION. PROVIDE EPO SWITCH AT LOCATION SHOWN ON POWER DRAWING. FIELD INSTALL SWITCH AND CONNECTION TO GENERATOR AS APPROVED BY MANUFACTURER AND NEC. PROVIDE CONDUIT AND WIRING FROM GENERATOR TO SWITCH LOCATION.PROVIDE CONTROL WIRING FOR AUTOMATIC TRANSFER SWITCHES AS REQUIRED. PROVIDE CONDUIT AND WIRING FOR GENERATOR BATTERY CHARGER AND BLOCK HEATER AS SHOWN ON ELECTRICAL FLOOR PLANS. SIZE PER N.E.C. TABLE 250.66. REFER TO SPEC SECTION 26 05 26 FOR ADDITIONAL INFORMATION SECONDARY TRANSFORMER CONDUCTOR LENGTH NOT TO EXCEED 10'-0" CONC. PAD REFER TO DETAIL 'N' ON E5-SERIES DRAWINGS FOR SERVICE EQUIPMENT DETAIL. KROGER TRANSFORMER PPA3 M.L.O. NEMA 1 TO PROTOCOL UNITS DEF2DEF1 LHA# DB DB DB DB DB DB DB DB DB DB DB DB M DB DB DB DB EC DB G DB DB DB DB DB DB DB DB DB SP SP SP DB DB DB DB EPM 2200 i.LON SMART SERVER PROVIDE A SELECTIVE COORDINATION STUDY FOR ENTIRE LIFE SAFETY SYSTEM FROM POINT OF GENERATION (GENERATOR AND MSB) DOWN TO BRANCH CIRCUIT BREAKERS. SYSTEM TO BE SELECTIVELY COORDINATED TO 0.1 SECONDS. NOTE FOR SWITCHGEAR MFGR: 1600-4A 225-4A 225-4A 225-4A 400-4A 100-4C 150-4AI 50-4C D200-4AI 200-4AI 800-3A 3 200-4A 600-4A JB 20-2C 20-2C 40-4C 10 125-3C 400-4A 150-4A 150-4AI 200-4A 80-4C 400-4A 80-4C 100-4C 10 400-4A 20-2C 225-4A 225-4A D200-4AI 125-4AI 200-4C 20-3C 13 13 1 5 3 20-2C 225-4A 1 5 20-2C 18 30-2C 30-2C 1600-4A 14 1 175-4A 16 50-4C 150-4A 175-4A 17 U2500-4A 2 23 40-4C 225-4A 225-4A 24 DB BALER 100 80 NEMA 1EC NEMA 1EC NEMA 1EC NEMA 1EC 3 ST 200 150 DB 100 50 DB 200 150 DB DB M.L.O. 225A LD2 200 DB 200 DB BALER NEMA 1 70 DB UTENSIL WASHER TO LIGHTING LOADS 3 30 30 30 NEMA 1 NEMA 1 NEMA 3R DB DB DB FCU-1 RCP-1 E19BE RED BOX NEMA 3R DB 30 25 PANEL LD2600A/3P400A/3P400A/3P150A/3P225A/3P225A/3P80A/3P225A/3P1 225A/3P2 225A/3P3 225A/3P4 225A/3P5 225A/3P6 225A/3P7 225A/3P9 225A/3P10 225A/3P11 50A/3P13 LEHB1 LEHB2DB DB LHA# TO LIGHTING LOADS 225A/3P8 14 15 200A/3P16 100A3P12 SPARESPACESPACE7 225A/3P23 24 25 225-4A M.L.O. 225A HB DB LHB# DB TO LIGHTING LOADS 225-4A DB M.L.O. 225A HC DB LHC# DB TO LIGHTING LOADS 225-4A 125 125 100 125-4C 100-4A125A/3P100A/3P125-4A 125 125125A/3P70-4C 100 7070A/3P15 50A/3P16 50A/3P17 200A/3P18 225A/3P19 20 SPARESPAREDOAS-1 50-4C50-4C DOAS-2 M.L.O. 225A LF2 DB 225-4A SEWAGE EJECTOR PUMP M DB 20-4C 20-4C LLF1 TO LIGHTING LOADSDB 1 23 24 1 TYP. 4 11 5 TYP. 12 SP SP SP SP 6 8 15 SPARESPARESEE E6.1.2 FOR CONTACTOR SCHEDULES N.T.S PANEL PPA3 PANEL PPA3 FLUSH COORDINATE PRIMARY VOLTAGE WITH UTILITY COMPANY PRIOR TO INSTALLATION 1. SEE SHEET E6.2.1 THROUGH E6.2.4 FOR CONTACTOR SCHEDULES. INSTALL "BC" LIGHTING CONTROL INTERFACE ("LCI" - FURNISHED BY EQT. MFR.) NEAR CONTACTOR. PROVIDE (1) 3/4" EMPTY CONDUIT FROM CONTACTOR TO "LCI" AND FROM "LCI" TO "BC" CONTROL PANEL. PROVIDE TWO 20A / 120V DEDICATED CONTROL POWER CIRCUITS, FED FROM NEARBY 120/208 VOLT PANELBOARD, ONE FOR CONTACTOR COIL(S) AND ONE FOR LIGHTING CONTROL INTERFACE(S). MULTIPLE CONTACTOR COILS AND MULTIPLE LIGHTING CONTROL INTERFACES MAY SHARE THE RESPECTIVE CONTROL POWER CIRCUITS. PROVIDE 20A / 1P BRANCH BREAKERS IN SOURCE PANELBOARD (EVEN IF NOT SCHEDULED). THE COIL VOLTAGE AND LINE VOLTAGE SHOULD MATCH FOR ALL CONTACTORS. ALL CONTROLLED CIRCUITS SHALL BE ROUTED THROUGH CONTACTORS. 2. UTILITY METERING POINT; ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING TERMINATIONS WITH UTILITY. LOCATION OF METER WILL BE COORDINATED WITH UTILITY. METERING SHALL BE INSTALLED PER LOCAL ELECTRICAL UTILITY GUIDELINES. 3. PROVIDE 6 INCH HIGH REINFORCED CONCRETE HOUSEKEEPING PAD WITH CHAMFERED CORNERS. 4. LOCAL EQUIPMENT DISCONNECT SWITCH, FOR RTU'S, WILL BE FURNISHED BY ROOFTOP EQUIPMENT MANUFACTURER. NOTE THAT ROOFTOP UNIT IS NOT UL LISTED/LABELED FOR ALUMINUM WIRING CONNECTIONS. EITHER CONVERT TO COPPER CONDUCTORS VIA A UL LISTED AND APPROVED SPLICE IN AN ADJACENT JUNCTION BOX (IN JOIST SPACE IMMEDIATELY BELOW ROOFTOP UNIT) AS INDICATED, OR PROVIDE COPPER CONDUCTORS THE ENTIRE LENGTH OF THE CIRCUIT. 5. RECEIVE AND INSTALL ALL SWITCHBOARDS AND PANELBOARDS (WITH FEEDERS). MARKED ELECTRICAL EQUIPMENT (TAGGED WITH DB) WILL BE FURNISHED BY OWNER. 6. PROVIDE ELECTRICAL POWER WORK FOR ROOFTOP REFRIGERATION SYSTEM CONDENSERS, SEE ROOF PLAN AND PROTOCOL DETAIL ON E5.6. PROVIDE (1) EMPTY 1 INCH CONDUIT FROM EACH CONDENSER TO ITS RESPECTIVE RACK OR PROTOCOL UNIT, CONDUIT SHALL CONTAIN PULL STRING. 7. KROGER PROVIDED PAD MOUNT SERVICE TRANSFORMER. COORDINATE INSTALLATION AND ANY ADDITIONAL REQUIREMENTS WITH LOCAL UTILITY COMPANY. SEE DETAIL ON E5-SERIES DRAWINGS FOR TRANSFORMER PAD AND RACEWAY INSTALLATION REQUIREMENTS. SEE CIVIL DRAWINGS FOR TRANSFORMER LOCATION AND ANY SITE WORK REQUIRED FOR BRINGING SERVICE INTO TRANSFORMER EQUIPMENT. 8. PROTOCOL UNITS ARE PACKAGE SUPPLEMENTAL REFRIGERATION UNITS. RELATED PANELBOARDS WILL UTILIZE BRANCH CIRCUIT BREAKERS THAT HAVE INTEGRAL CONTACTS TO CONTROL DEFROST LOADS, WHICH WILL BE ELECTRONICALLY OPERATED FROM THE RESPECTIVE PROTOCOL UNIT CONTROL SYSTEM. THESE PANELBOARDS WILL COLLECTIVELY FEED PROTOCOL UNIT COMPRESSORS, PROTOCOL UNIT CONTROL DEVICES, REMOTE CASE ELECTRIC DEFROSTS, ETC. PROVIDE ALL CONDUIT, WIRING AND TERMINATION WORK ASSOCIATED WITH HOME- RUNS FROM REMOTE CASES / EQUIPMENT. FIELD VERIFY BRANCH CIRCUIT SIZES, TERMINATION REQUIREMENTS AND CIRCUIT DESIGNATIONS FOR ALL RELATED LOADS FROM REFRIGERATION EQUIPMENT VENDOR. ROUTE ALL CASE LIGHTING HOME-RUNS THROUGH CONTACTOR. UNIT REMOTE CASE FANS, REMOTE CASE LIGHTS AND REMOTE CASE ANTI-SWEATS ARE FED FROM OTHER ELECTRICAL PANELS AND CONTROLLED THROUGH CASE CONTROLLER. FIELD VERIFY REQUIRED FUSES SIZES FOR THE FUSIBLE DISCONNECT SWITCHES THAT SERVE ALL PROTOCOL EQUIPMENT. FIELD VERIFY ALL CIRCUIT / HOME-RUN DESIGNATIONS FOR ALL LOADS FED FROM PROTOCOL EQUIPMENT. COORDINATE ALL RELATED WORK IN DETAIL WITH PROTOCOL UNIT EQUIPMENT VENDOR PRIOR TO ROUGH-IN. WIRE ALL PANELBOARDS LOCATED WITHIN THE PROTOCOL UNIT, WHICH SHALL BE FURNISHED AND INSTALLED BY REFRIGERATION EQUIPMENT VENDOR. INSTALL AND WIRE ALL REMOTE PANELBOARDS LOCATED NEAR PROTOCOL, WHICH SHALL BE FURNISHED BY REFRIGERATION EQUIPMENT VENDOR. 9. PROVIDE 6 INCH CONDUIT, PLUS (1) SPARE 6 INCH CONDUIT FROM METERING CABINET TO INTERRUPTER SWITCH. PROVIDE CONDUIT AND WIRE FROM INTERRUPTER SWITCH TO TRANSFORMER AS SHOWN. PROVIDE CONCRETE ENCASEMENT OF ALL EXTERIOR UNDERGROUND SERVICE CONDUITS. REFER TO SITE CIVIL PLANS FOR LOCATION AND ANY SPECIAL ELECTRICAL SERVICE REQUIREMENTS. COORDINATE INSTALLATION OF ELECTRICAL SERVICE WITH LOCAL UTILITY COMPANY. INTERRUPTER SWITCH AND METERING CABINET PROVIDED BY KROGER. 10. REFER TO TRANSFORMER GROUNDING TABLE FOR GROUND WIRE SIZE. 11. NEMA 3R COMBINATION STARTER WITH FUSIBLE DISCONNECT FOR DELI HOOD. STARTER SHALL BE 208 VOLT, 3 PHASE, NEMA 0 WITH (1) NORMALLY OPEN AND (1) NORMALLY CLOSED AUXILIARY CONTACTS AND OVERLOADS WITH H-O-A SELECTOR SWITCH. CONTROL POWER SHALL BE 120 VOLT. REFER TO E5-SERIES DRAWINGS FOR ADDITIONAL WIRING INSTRUCTIONS AND ROOF PLAN FOR ADDITIONAL INSTALLATION DETAILS. 12. CONDUIT AND WIRE SHALL ORIGINATE IN FUTURE SPACE, PROVIDE WIRE PULLING BOXES AS REQUIRED ALONG RACEWAY PATH BACK TO SWITCHBOARD. 13. SHUNT TRIP BREAKERS TO BE CONTROLLED BY KIRK-KEY AT 1600 AMP GENERATOR BACK-UP SECTION. 14. NEMA 3R BUSSED ENCLOSURE WITH QUICK CONNECT RECEPTACLES IN AND LUG / CABLE OUT. EXTERIOR MOUNTED FOR CONNECTION OF TEMPORARY MOBILE GENERATOR. RACEWAY SYSTEM(S) FROM MSB TO MGC SHALL BE INSTALLED UNDERGROUND. 15. CERTIFIED PROTOCOL SHOP DRAWINGS MUST BE RECEIVED AND APPROVED PRIOR TO ORDERING ELECTRICAL PANELS, CIRCUIT BREAKERS, FUSES, AND WIRING FOR THE PROTOCOL UNITS. ANY DEVIATIONS IN ACTUAL APPROVED PROTOCOL SHOP DRAWINGS VERSUS DESIGN MUST BE VERIFIED AND EQUIPMENT ORDERS ADJUSTED TO MATCH ACTUAL SUBMITTAL DRAWINGS. 16. PROVIDE 6 INCH HIGH CONCRETE HOUSEKEEPING EQUIPMENT PAD FOR EXTERIOR GENERATOR. PAD SHALL EXTEND OUT 6 INCHES PAST THE GENERATOR HOUSING, COORDINATE PAD WITH GENERATOR SUBMITTAL DRAWINGS. 17. LOCATE FUSED DISCONNECT SWITCH ADJACENT TO GENERATOR, ON EXTERIOR OF BUILDING. 18. REFER TO ESD-6 ON E5-SERIES DRAWINGS FOR ADDITIONAL WIRING REQUIREMENTS. 19. PROVIDE CIRCUIT TO FEED FUEL CENTER. CIRCUIT SHALL EXTEND TO SITE PULLBOX FOR CONTINUATION TO FUEL CENTER TRANSFORMER. REFER TO DRAWING E1.6. FOR LOCATION OF BULL BOX. COORDINATE CONTINUATION OF CIRCUIT WITH SITE ELECTRICAL CONTRACTOR. 20. INSTALL PRIMARY LOAD INTERRUPTER SWITCH WITH FUSING. PARK DETROIT MODEL #PM315-15-95 (FURNISHED BY KROGER). PROVIDE CONCRETE PAD FOR SWITCH COORDINATE LOCATION WITH LOCAL UTILITY. 21. INSTALL PRIMARY METERING CABINET FURNISHED BY LOCAL UTILITY. COORDINATE INSTALLATION WITH LOCAL UTILITY FOR SITE LOCATION, AND RACEWAY TERMINATION AREAS. 22. PROVIDE CONCRETE PAD PER LOCAL UTILITY SPECIFICATIONS FOR PRIMARY METERING EQUIPMENT. COORDINATE LOCATION WITH UTILITY. 23. ENERGY REDUCING MAINTENANCE SWITCH WITH LOCAL STATUS INDICATOR, PER REQUIREMENTS OF NEC (2017) 240.87. 24. ALL EMERGENCY PANELS SHALL HAVE A FACTORY INSTALLED UL LISTED, SPD (SURGE PROTECTION DEVICE) IN COMPLIANCE WITH NEC 700.8. SINGLE LINE KEYNOTES SPACES AS AVAILABLE SPACESPACESPACESPACESPACESPACESPACESPACEEC PROVIDED BREAKERS M.L.O. 400A LK FLUSH DB 400-4A M.L.O. 225A LL DB 225-4A M.L.O. 225A LM1 DB 225-4A 100 150 kVA 3∅/4-WIRE TLH TRANSFORMER 480V TO 208Y/120V GROUND PER N.E.C. SECONDARY TRANSFORMER CONDUCTOR LENGTH NOT TO EXCEED 10'-0" DB 400-4A 3 10 M.L.O. 225A LM2 DB (3)#8 CU AWG & (1)#10 CU AWG GND IN 3/4" CONDUIT50-3C FEEDER SCHEDULE GENERAL NOTES ●FEEDERS DENOTED BY A "*" HAVE BEEN OVERSIZED TO COMPENSATE FOR VOLTAGE DROP. ●"CU" = COPPER CONDUCTOR ●"AL" = ALUMINUM CONDUCTOR ●IF ALUMINUM CONDUCTORS ARE USED FOR ANY FEEDER AND LUGS/TRANSFORMER COMPARTMENT DO NOT ALLOW THE INCREASED SIZE, COPPER CONDUCTORS SHALL BE INSTALLED. 150-4A 600-4A D200-4AI 400-4A 225-4A 175-4A 200-4AI 150-4AI 125-4A 200-4A (4)#1 AL AWG & (2)#4 AL AWG GND IN 2" CONDUIT100-4AI (3)#4 CU AWG & (1)#8 CU AWG GND IN 1" CONDUIT80-3C (4)#6 CU AWG & (1)#10 CU AWG GND IN 1" CONDUIT60-4C (4)#8 CU AWG & (1)#10 CU AWG GND IN 1" CONDUIT50-4C (3)#10 CU AWG & (1)#10 CU AWG GND IN 3/4" CONDUIT30-3C (2)#10 CU AWG & (1)#10 CU AWG GND IN 3/4" CONDUIT30-2C (4)#12 CU AWG & (1)#12 CU AWG GND IN 3/4" CONDUIT20-4C (3)#12 CU AWG & (1)#12 CU AWG GND IN 3/4" CONDUIT20-3C (3)#6 CU AWG & (1)#10 CU AWG GND IN 1" CONDUIT60-3C 150-4C 110-4A 110-3AI 100-4A 800-3A U2500-4A D1200-4A (4)#300 kcmil AL AWG & (1)#2 AL AWG GND IN 2-1/2" CONDUIT (4)#1/0 CU AWG & (1)#6 CU AWG GND IN 2" CONDUIT (3)#1/0 AL AWG & (2)#4 AL AWG GND IN 2" CONDUIT (4)#1 AL AWG & (1)#6 AL AWG GND IN 1-1/2" CONDUIT (3) SETS OF (3)#400 kcmil AL AWG & (1)#3/0 AL AWG GND IN 3" CONDUIT EACH (7) SETS OF (4)#750 kcmil AL AWG IN 4" CONDUIT EACH (4) SETS OF (4)#500 kcmil AL AWG & (1)#250 kcmil AL AWG GND IN 3" CONDUIT EACH (4)#1/0 AL AWG & (1)#4 AL AWG GND IN 2" CONDUIT (4)#250 kcmil AL AWG & (1)#4 AL AWG GND IN 2-1/2" CONDUIT (4)#2/0 AL AWG & (1)#4 AL AWG GND IN 2" CONDUIT (4)#3/0 AL AWG & (1)#4 AL AWG GND IN 2" CONDUIT (4)#3/0 AL AWG & (2)#4 AL AWG GND IN 2" CONDUIT (4)#250 kcmil AL AWG & (2)#4 AL AWG GND IN 2-1/2" CONDUIT (4)#4/0 AL AWG & (1)#4 AL AWG GND IN 2-1/2" CONDUIT (2) SETS OF (4)#250 kcmil AL AWG & (1)#1 AL AWG GND IN 2-1/2" CONDUIT EACH (4)#250 kcmil AL AWG & (2)#1/0 AL AWG GND'S IN 3" CONDUIT (2) SETS OF (4)#500 kcmil AL AWG & (1)#2/0 AL AWG GND IN 3" CONDUIT EACH (4)#1 CU AWG & (2)#6 CU AWG GND IN 2" CONDUIT125-4C * ALL ISOLATED GROUND CONDUCTORS SHALL BE * CONTINUED TO SERVICE ENTRANCE GROUND BAR. CONDUCTOR MATERIAL COPPER (C) VS. ALUMINUM (A) NUMBER OF CONDUCTORS CONDUCTOR AMPACITY GROUND SIZED FOR DERIVED SERVICE (D) OR REMOVED FOR SERVICE ENTRANCE FROM UTILITY (U). SPECIAL - ISOLATED GROUND (I) CONDUCTOR NOMENCLATURE FEEDER SIZED TO COMPENSATE FOR VOLTAGE DROP D250-4AI* WIRE FEEDER SCHEDULE 225-4C (4)#4/0 CU AWG & (1)#4 CU AWG GND IN 2-1/2" CONDUIT D400-4A (2) SETS OF (4)#350 kcmil AL AWG & (1)#4/0 kcmil AL AWG GND IN 3" CONDUIT EACH (2)#12 CU AWG & (1)#12 CU AWG GND IN 3/4" CONDUIT20-2C 110-3C (3)#2 CU AWG & (1)#6 CU AWG GND IN 1-1/2" CONDUIT D200-4A (4)#250 kcmil AL AWG & (1)#1/0 AL AWG GND'S IN 3" CONDUIT 175-3A (3)#4/0 AL AWG & (1)#4 AL AWG GND IN 2-1/2" CONDUIT (4)#3 CU AWG & (1)#6 CU AWG GND IN 1-1/2" CONDUIT90-4C (4)#4 CU AWG & (1)#10 CU AWG GND IN 1" CONDUIT80-4C 1600-4A (5) SETS OF (4)#600 kcmil AL AWG & (1)#350 kcmil AL AWG GND IN 3-1/2" CONDUIT EACH (4)#2 AL AWG & (1)#6 AL AWG GND IN 1" CONDUIT80-4A 110-4C (4)#2 CU AWG & (1)#6 CU AWG GND IN 2" CONDUIT 100-4C (4)#3 CU AWG & (1)#8 CU AWG GND IN 2" CONDUIT 125-3C (3)#2/0 CU AWG & (1)#4 CU AWG GND IN 2" CONDUIT 250-4A (4)#350 kcmil AL AWG & (1)#4/0 kcmil AL AWG GND IN 3" CONDUIT EACH (4)#4CU AWG & (1)#10 CU AWG GND IN 1" CONDUIT70-4C