Loading...
HomeMy WebLinkAboutKECHTER TOWNHOMES - FDP210002 - - UTILITY PLANSKECHTER RD FOSSIL CREEK RESERVOIR PROJECT LOCATION I-25 // US 87E HARMONY RD STRAUSS CABIN RDZIEGLER RDROCK CREEK DR 16' 7' PARK TRAVEL 7' PARK 7' (MIN.) PKWY 30' ROADWAY 53' ROW (MIN) WALK 4.5' 6'.5 Min. Fence Setback UTIL. ESMT. 9' 9'UTIL. ESMT. (MIN.) PKWY 7' WALK (MIN) 4.5' CS1 COVER STEET1 JULY 2020 CONTACT INFORMATION PROJECT TEAM: VICINITY MAP NORTH KECHTER TOWNHOMES PROJECT TEAM: Ripley Design, Inc Russell Lee 419 Canyon Avenue, Suite 200 Fort Collins, Colorado 80521 (970) 224.5828 TWG Ryan Kelly, Acquisitions Director 1301 East Washington Street, Ste 100 Indianapolis, IN 46202 (317)559-7009 Northern Engineering Services, Inc. Andy Reese 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 (970) 221-4158 PLANNER/ LANDSCAPE ARCHITECT OWNER/APPLICANT SITE ENGINEER SHEET INDEX A TRACT OF LAND LOCATED IN THE SOUTHEAST QUARTER OF SECTION 4, TOWNSHIP 6 NORTH, RANGE 68 WEST OF THE 6TH P.M. CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO Northern Engineering Services, Inc. Bob Tessely, PLS 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 (970) 221-4158 SITE SURVEYOR TYPICAL SECTIONS 1 CS1 COVER SHEET 2 CS2 GENERAL & CONSTRUCTION NOTES 3 - 4 EX1 - EX2 EXISTING CONDITIONS & DEMOLITION PLAN 5 - 6 PV1 - PV2 PAVING PLAN UTILITY SHEETS 7 OU1 OVERALL UTILITY PLAN 8 - 9 U1 - U2 UTILITY PLAN 10 - 11 SS1 - SS2 SANITARY SEWER PLAN & PROFILE 12 - 14 ST1 - ST3 STORM SEWER PLAN & PROFILE 15 - 17 WT1 - WT3 WATER MAIN PLAN & PROFILE GRADING SHEETS 18 OG1 OVERALL GRADING PLAN 19 - 20 G1 - G2 GRADING PLAN ROADWAY SHEETS 21 R1 WHEELHOUSE WAY & LOGGERS LANE PLAN & PROFILE 22 R2 CACTUS CURVE & CACTUS CURVE PLAN & PROFILE 23 R3 QUASAR WAY PLAN & PROFILE 24 R4 KECHTER ROAD RE-STRIPING PLAN DETAIL SHEETS 25 - 26 D1 - D2 SITE DETAILS 27 - 28 D3 - D4 UTILITY DETAILS 29 - 30 D5 - D6 DRAINAGE DETAILS DRAINAGE SHEETS 31 EC1 OVERALL EROSION CONTROL PLAN 32 - 33 EC2 - EC3 EROSION CONTROL PLAN 34 EC4 EROSION CONTROL DETAILS 35 DR1 DRAINAGE EXHIBIT UTILITY PLANS FOR UTILITY CONTACT LIST: * UTILITY COMPANY * This list is provided as a courtesy reference only. Northern Engineering Services assumes no responsibility for the accuracy or completeness of this list. In no way shall this list relinquish the Contractor's responsibility for locating all utilities prior to commencing any construction activity. Please contact the Utility Notification Center of Colorado (UNCC) at 811 for additional information. PHONE NUMBER GAS-----------------Xcel Energy-----------------------------Pat Kreager (970) 225-7840 ELECTRIC--------City of Fort Collins Light & Power--Rob Irish (970) 224-6167 CABLE-------------Comcast----------------------------------Don Kapperman (970) 567-0425 TELECOM.--------CenturyLink-------------------------------William Johnson (970) 377-6401 WATER------------Fort Collins Loveland Water----------Chris Pletcher (970) 226-3104 WASTEWATER--South Fort Collins Sanitation --------Chris Pletcher (970) 226-3104 STORMWATER-City of Fort Collins Utilities-----------Wes Lamarque (970) 416-2418 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 35 ■ land planning ■ landscape architecture ■ ■ urban design ■ entitlement ■ Design Studio Aldo Sebben 1350 Pine Street, Suite 6 Boulder, Colorado 80302 (303) 250.9525 ARCHITECT I hereby affirm that these final construction plans were prepared under my direct supervision, in accordance with all applicable City of Fort Collins and State of Colorado standards and statutes, respectively; and that I am fully responsible for the accuracy of all design. revisions, and record conditions that I have noted on these plans. These plans have been reviewed by the City of Fort Collins for concept only. The review does not imply responsibility by the reviewing department, the City of Fort Collins Engineer, or the City of Fort Collins for accuracy and correctness of the calculations. Furthermore, the review does not imply that quantities of items on the plans are the final quantities required. The review shall not be construed for any reason as acceptance of financial responsibility by the City of Fort Collins for additional quantities of items shown that may be required during the construction phase. DISCLAIMER STATEMENT: CERTIFICATION STATEMENT: BENCHMARK #1: City of Fort Collins Benchmark 2-03 Location: South side Kechter Road approximately 0.6 miles west of Strauss Cabin Road on the east end of the south parapet wall of the bridge over the Dixon Canyon Lateral. Elevation= 4898.14 (NAVD88) BENCHMARK #2: City of Fort Collins Benchmark 13-13 Location: On the west side of Strauss Cabin Road, approximately 90-ft south of Kechter Road, on the northwest corner of a storm inlet. Elevation= 4887.05 (NAVD88) Please note: This plan set is using NAVD88 for a vertical datum. Surrounding developments have used NGVD29 Unadjusted Datum (prior City of Fort Collins Datum) for their vertical datums. If NGVD29 Unadjusted Datum (prior City of Fort Collins Datum) is required for any purpose, the following equation should be used: NGVD29 Unadjusted Datum (prior City of Fort Collins Datum) = NAVD88 - 3.18' Basis of Bearings South line of the Southeast Quarter of Section 4-6-68 as bearing South 88°11'39" East. Original Field Survey Northern Engineering Services, INC. Project Number: 1664-003 Date: June, 2020 ORIGINAL FIELD SURVEY BY: PROJECT BENCHMARKS: (53' FL-FL) RESIDENTIAL LOCAL STREET N.T.S.All changes, addendums, additions, deletions and modifications to these drawings must be approved, in writing, by the Fort Collins-Loveland Water District and the South Fort Collins Sanitation District. District Engineer Date FORT COLLINS - LOVELAND WATER DISTRICT SOUTH FORT COLLINS SANITATION DISTRICT CS2 CONSTRUCTION NOTESGENERAL &2 SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 35 A. GENERAL NOTES 1.All materials, workmanship, and construction of ppublic improvements shall meet or exceed the standards and specifications set forth in the Larimer County Urban Area Street Standards and applicable state and federal regulations. Where there is conflict between these plans and the specifications, or any applicable standards, the most restrictive standard shall apply. All work shall be inspected and approved by the City of Fort Collins. 2.All references to any published standards shall refer to the latest revision of said standard, unless specifically stated otherwise. 3.These public improvement construction plans shall be valid for a period of three years from the date of approval by the City of Fort Collins Engineer. Use of these plans after the expiration date will require a new review and approval process by the City of Fort Collins prior to commencement of any work shown in these plans. 4.The engineer who has prepared these plans, by execution and/or seal hereof, does hereby affirm responsibility to the City of Fort Collins, as beneficiary of said engineer's work, for any errors and omissions contained in these plans, and approval of these plans by the City of Fort Collins Engineer shall not relieve the engineer who has prepared these plans of all such responsibility. Further, to the extent permitted by law, the engineer hereby agrees to hold harmless and indemnify the City of Fort Collins, and its officers and employees, from and against all liabilities, claims, and demands which may arise from any errors and omissions contained in these plans. 5.All storm sewer construction, as well as power and other "dry" utility installations, shall conform to the City of Fort Collins standards and specifications current at the date of approval of the plans by the City of Fort Collins Engineer. 6.The type, size, location and number of all known underground utilities are approximate when shown on the drawings. It shall be the responsibility of the Developer to verify the existence and location of all underground utilities along the route of the work before commencing new construction. The Developer shall be responsible for unknown underground utilities. 7.The Developer shall comply with all terms and conditions of the Colorado Permit for Storm Water Discharge (Contact Colorado Department of Health, Water Quality Control Division, (303) 692-3590), the Storm Water Management Plan, and the Erosion Control Plan. 8.The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 9.Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must be submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. 10.The City of Fort Collins shall not be responsible for any damages or injuries sustained in this Development as a result of groundwater seepage, whether resulting from groundwater flooding, structural damage or other damage unless such damage or injuries are sustained as a result of the City of Fort Collins failure to properly maintain its water, wastewater, and/or storm drainage facilities in the development. 11.All recommendations of the Preliminary Drainage Report, dated July 22, 2020 by Northern Engineering Services, Inc., shall be followed and implemented. 12.Temporary erosion control during construction shall be provided as shown on the Erosion Control Plan. All erosion control measures shall be maintained in good repair by the Developer, until such time as the entire disturbed areas is stabilized with hard surface or landscaping. 13.The Developer shall be responsible for insuring that no mud or debris shall be tracked onto the existing public street system. Mud and debris must be removed within 24 hours by an appropriate mechanical method (i.e. machine broom sweep, light duty front-end loader, etc.) or as approved by the the City of Fort Collins street inspector. 14.No work may commence within any improved or unimproved public Right-of-Way until a Right-of-Way Permit or Development Construction Permit is obtained, if applicable. 15.The Developer shall be responsible for obtaining all necessary permits for all applicable agencies prior to commencement of construction. The Developer shall notify the the City of Fort Collins Inspector (Fort Collins - 221-6605) and the City of Fort Collins Erosion Control Inspector (Fort Collins - 221-6700) at least 2 working days prior to the start of any earth disturbing activity, or construction on any and all public improvements. If the City of Fort Collins Engineer is not available after proper notice of construction activity has been provided, the Developer may commence work in the Engineer's absence. However, the City of Fort Collins reserves the right not to accept the improvement if subsequent testing reveals an improper installation. 16.The Developer shall be responsible for obtaining soils tests within the Public Right-of-Way after right of way grading and all utility trench work is complete and prior to the placement of curb, gutter, sidewalk and pavement. If the final soils/pavement design report does not correspond with the results of the original geotechnical report, the Developer shall be responsible for a re-design of the subject pavement section or, the Developer may use the City of Fort Collins' default pavement thickness section(s). Regardless of the option used, all final soils/pavement design reports shall be prepared by a licensed Professional Engineer. The final report shall be submitted to the Inspector a minimum of 10 working days prior to placement of base and asphalt. Placement of curb, gutter, sidewalk, base and asphalt shall not occur until the City of Fort Collins Engineer approves the final report. 17.The contractor shall hire a licensed engineer or land surveyor to survey the constructed elevations of the street subgrade and the gutter flowline at all intersections, inlets, and other locations requested by the the City of Fort Collins inspector. The engineer or surveyor must certify in a letter to the City of Fort Collins that these elevations conform to the approved plans and specifications. Any deviations shall be noted in the letter and then resolved with the City of Fort Collins before installation of base course or asphalt will be allowed on the streets. 18.All utility installations within or across the roadbed of new residential roads must be completed prior to the final stages of road construction. For the purposes of these standards, any work except c/g above the subgrade is considered final stage work. All service lines must be stubbed to the property lines and marked so as to reduce the excavation necessary for building connections. 19.Portions of Larimer County are within overlay districts. The Larimer County Flood Plain Resolution should be referred to for additional criteria for roads within these districts. 20.All road construction in areas designated as Wild Fire Hazard Areas shall be done in accordance with the construction criteria as established in the Wild Fire Hazard Area Mitigation Regulations in force at the time of final plat approval. 21.Prior to the commencement of any construction, the contractor shall contact the Local Entity Forester to schedule a site inspection for any tree removal requiring a permit. 22.The Developer shall be responsible for all aspects of safety including, but not limited to, excavation, trenching, shoring, traffic control, and security. Refer to OSHA Publication 2226, Excavating and Trenching. 23.The Developer shall submit a Construction Traffic Control Plan, in accordance with MUTCD, to the appropriate Right-of-Way authority. (The the City of Fort Collins, Larimer County, Colorado), for approval, prior to any construction activities within, or affecting, the Right-of-Way. The Developer shall be responsible for providing any and all traffic control devices as may be required by the construction activities. 24.Prior to the commencement of any construction that will affect traffic signs of any type, the contractor shall contact the City of Fort Collins Traffic Operations Department, who will temporarily remove or relocate the sign at no cost to the contractor, however, if the contractor moves the traffic sign then the contractor will be charged for the labor, materials and equipment to reinstall the sign as needed. 25.The Developer is responsible for all costs for the initial installation of traffic signing and striping for the Development related to the Development's local street operations. In addition, the Developer is responsible for all costs for traffic signing and striping related to directing traffic access to and from the Development. 26.There shall be no site construction activities on Saturdays, unless specifically approved by the City of Fort Collins Engineer, and no site construction activities on Sundays or holidays, unless there is prior written approval by Larimer County. 27.The Developer is responsible for providing all labor and materials necessary for the completion of the intended improvements, shown on these drawings, or designated to be provided, installed, or constructed, unless specifically noted otherwise. 28.Dimensions for layout and construction are not to be scaled from any drawing. If pertinent dimensions are not shown, contact the Designer for clarification, and annotate the dimension on the as-built record drawings. 29.The Developer shall have, onsite at all times, one (1) signed copy of the approved plans, one (1) copy of the appropriate standards and specifications, and a copy of any permits and extension agreements needed for the job. 30.If, during the construction process, conditions are encountered which could indicate a situation that is not identified in the plans or specifications, the Developer shall contact the Designer and the City of Fort Collins Engineer immediately. 31.The Developer shall be responsible for recording as-built information on a set of record drawings kept on the construction site, and available to the Larimer County's Inspector at all times. Upon completion of the work, the contractor(s) shall submit record drawings to the City of Fort Collins Engineer. 32.The Designer shall provide, in this location on the plan, the location and description of the nearest survey benchmarks (2) for the project as well as the basis of bearings. The information shall be as follows: BENCHMARK #1: City of Fort Collins Benchmark 2-03 Location: South side Kechter Road approximately 0.6 miles west of Strauss Cabin Road on the east end of the south parapet wall of the bridge over the Dixon Canyon Lateral. Elevation= 4898.14 (NAVD88) BENCHMARK #2: City of Fort Collins Benchmark 13-13 Location: On the west side of Strauss Cabin Road, approximately 90-ft south of Kechter Road, on the northwest corner of a storm inlet. Elevation= 4887.05 (NAVD88) Please note: This plan set is using NAVD88 for a vertical datum. Surrounding developments have used NGVD29 Unadjusted Datum (prior City of Fort Collins Datum) for their vertical datums. If NGVD29 Unadjusted Datum (prior City of Fort Collins Datum) is required for any purpose, the following equation should be used: NGVD29 Unadjusted Datum (prior City of Fort Collins Datum) = NAVD88 - 3.18' Basis of Bearings South line of the Southeast Quarter of Section 4-6-68 as bearing South 88°11'39" East. 33.All stationing is based on centerline of roadways unless otherwise noted. 34.Damaged curb, gutter and sidewalk existing prior to construction, as well as existing fences, trees, streets, sidewalks, curbs and gutters, landscaping, structures, and improvements destroyed, damaged or removed due to construction of this project, shall be replaced or restored in like kind at the Developer's expense, unless otherwise indicated on these plans, prior to the acceptance of completed improvements and/or prior to the issuance of the first Certificate of Occupancy. 35.When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the City of Fort Collins Construction Inspector before any cuts are made. Patching shall be done in accordance with the City of Fort Collins Street Repair Standards. The finished patch shall blend in smoothly into the existing surface. All large patches shall be paved with an asphalt lay-down machine. In streets where more than one cut is made, an overlay of the entire street width, including the patched area, may be required. The determination of need for a complete overlay shall be made by the Larimer County Engineer and/or the City of Fort Collins Inspector at the time the cuts are made. 36.Upon completion of construction, the site shall be cleaned and restored to a condition equal to, or better than, that which existed before construction, or to the grades and condition as required by these plans. 37.Standard Handicap ramps are to be constructed at all curb returns and at all "T" intersections. 38.After acceptance by the City of Fort Collins, public improvements depicted in these plans shall be guaranteed to be free from material and workmanship defects for a minimum period of two years from the date of acceptance. 39.The City of Fort Collins shall not be responsible for the maintenance of roadway and appurtenant improvements, including storm drainage structures and pipes, for the following private streets: N.A. 40.Approved Variances are listed as follows: ·N/A CONSTRUCTION NOTES A. Grading and Erosion Control Notes 1.The erosion control inspector must be notified at least twenty-four (24) hours prior to any construction on this site. 2.There shall be no earth-disturbing activity outside the limits designated on the accepted plans. 3.All required perimeter silt and construction fencing shall be installed prior to any land disturbing activity (stockpiling, stripping, grading, etc). All other required erosion control measures shall be installed at the appropriate time in the construction sequence as indicated in the approved project schedule, construction plans, and erosion control report. 4.At all times during construction, the Developer shall be responsible for preventing and controlling on-site erosion including keeping the property sufficiently watered so as to minimize wind blown sediment. The Developer shall also be responsible for installing and maintaining all erosion control facilities shown herein. 5.Pre-disturbance vegetation shall be protected and retained wherever possible. Removal or disturbance of existing vegetation shall be limited to the area(s) required for immediate construction operations, and for the shortest practical period of time. 6.All soils exposed during land disturbing activity (stripping, grading, utility installations, stockpiling, filling, etc.) shall be kept in a roughened condition by ripping or disking along land contours until mulch, vegetation, or other permanent erosion control BMPs are installed. No soils in areas outside project street rights-of-way shall remain exposed by land disturbing activity for more than thirty (30) days before required temporary or permanent erosion control (e.g. seed/mulch, landscaping, etc.) is installed, unless otherwise approved by the City/County. 7.In order to minimize erosion potential, all temporary (structural) erosion control measures shall: a.Be inspected at a minimum of once every two (2) weeks and after each significant storm event and repaired or reconstructed as necessary in order to ensure the continued performance of their intended function. b.Remain in place until such time as all the surrounding disturbed areas are sufficiently stabilized as determined by the erosion control inspector. c.Be removed after the site has been sufficiently stabilized as determined by the erosion control inspector. 8.When temporary erosion control measures are removed, the Developer shall be responsible for the clean up and removal of all sediment and debris from all drainage infrastructure and other public facilities. 9.The contractor shall immediately clean up any construction materials inadvertently deposited on existing streets, sidewalks, or other public rights of way, and make sure streets and walkways are cleaned at the end of each working day. 10.All retained sediments, particularly those on paved roadway surfaces, shall be removed and disposed of in a manner and location so as not to cause their release into any waters of the United States. 11.No soil stockpile shall exceed ten (10) feet in height. All soil stockpiles shall be protected from sediment transport by surface roughening, watering, and perimeter silt fencing. Any soil stockpile remaining after thirty (30) days shall be seeded and mulched. 12.The stormwater volume capacity of detention ponds will be restored and storm sewer lines will be cleaned upon completion of the project and before turning the maintenance over to the City/County or Homeowners Association (HOA). 13.City Ordinance and Colorado Discharge Permit System (CDPS) requirements make it unlawful to discharge or allow the discharge of any pollutant or contaminated water from construction sites. Pollutants include, but are not limited to discarded building materials, concrete truck washout, chemicals, oil and gas products, litter, and sanitary waste. The developer shall at all times take whatever measures are necessary to assure the proper containment and disposal of pollutants on the site in accordance with any and all applicable local, state, and federal regulations. 14.A designated area shall be provided on site for concrete truck chute washout. The area shall be constructed so as to contain washout material and located at least fifty (50) feet away from any waterway during construction. Upon completion of construction activities the concrete washout material will be removed and properly disposed of prior to the area being restored. 15.Conditions in the field may warrant erosion control measures in addition to what is shown on these plans. The Developer shall implement whatever measures are determined necessary, as directed by the City. 16.See separate Stormwater Management Plan / Erosion Control Report for Waterfield Third Filing for additional information. 17.A vehicle tracking control pad shall be installed when needed for construction equipment, including but not limited to personal vehicles exiting existing roadways. No earthen materials, i.e. stone, dirt, etc. shall be placed in the curb & gutter or roadway as a ramp to access temporary stockpiles, staging areas, construction materials, concrete washout areas, and/or building sites. B. Street Improvement Notes 1.All street construction is subject to the General Notes on the cover sheet of these plans as well as the Street Improvements Notes listed here. 2.A paving section design, signed and stamped by a Colorado licensed Engineer, must be submitted to the City of Fort Collins Engineer for approval, prior to any street construction activity, (full depth asphalt sections are not permitted at a depth greater than 8 inches of asphalt). The job mix shall be submitted for approval prior to placement of any asphalt. 3.Where proposed paving adjoins existing asphalt, the existing asphalt shall be saw cut, a minimum distance of 12 inches from the existing edge, to create a clean construction joint. The Developer shall be required to remove existing pavement to a distance where a clean construction joint can be made. 4.Street subgrades shall be scarified the top 12 inches and re-compacted prior to subbase installation. No base material shall be laid until the subgrade has been inspected and approved by the City of Fort Collins Engineer. 5.Ft. Collins only. Valve boxes and manholes are to be brought up to grade at the time of pavement placement or overlay. Valve box adjusting rings are not allowed. 6.When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the Inspector before any cuts are made. Cutting and patching shall be done in conformance with Chapter 25, Reconstruction and Repair. The finished patch shall blend smoothly into the existing surface. The determination of need for a complete overlay shall be made by the City of Fort Collins Engineer. All overlay work shall be coordinated with adjacent landowners such that future projects do not cut the new asphalt overlay work. 7.All traffic control devices shall be in conformance with these plans or as otherwise specified in M.U.T.C.D. (including Colorado supplement) and as per the Right-of-Way Work Permit traffic control plan. 8.The Developer is required to perform a gutter water flow test in the presence of the City of Fort Collins Inspector and prior to installation of asphalt. Gutters that hold more than 1/4 inch deep or 5 feet longitudinally, of water, shall be completely removed and reconstructed to drain properly. 9.Prior to placement of H.B.P. or concrete within the street and after moisture/density tests have been taken on the subgrade material (when a full depth section is proposed) or on the subgrade and base material (when a composite section is proposed), a mechanical "proof roll" will be required. The entire subgrade and/or base material shall be rolled with a heavily loaded vehicle having a total GVW of not less than 50,000 lbs. and a single axle weight of at least 18,000 lbs. with pneumatic tires inflated to not less that 90 p.s.i.g. "Proof roll" vehicles shall not travel at speeds greater than 3 m.p.h. Any portion of the subgrade or base material which exhibits excessive pumping or deformation, as determined by the City of Fort Collins Engineer, shall be reworked, replaced or otherwise modified to form a smooth, non-yielding surface. The City of Fort Collins Engineer shall be notified at least 24 hours prior to the "proof roll." All "proof rolls" shall be preformed in the presence of an Inspector. C. Traffic Signing and Pavement Marking Construction Notes 1.All signage and marking is subject to the General Notes on the cover sheet of these plans, as well as the Traffic Signing and Marking Construction Notes listed here. 2.All symbols, including arrows, ONLYS, crosswalks, stop bars, etc. shall be pre-formed thermo-plastic. 3.All signage shall be per the City of Fort Collins Standards and these plans or as otherwise specified in MUTCD. 4.All lane lines for asphalt pavement shall receive two coats of latex paint with glass beads. 5.All lane lines for concrete pavement should be epoxy paint. 6.Prior to permanent installation of traffic striping and symbols, the Developer shall place temporary tabs or tape depicting alignment and placement of the same. Their placement shall be approved by the City of Fort Collins Traffic Engineer prior to permanent installation of striping and symbols. 7.Pre-formed thermo-plastic applications shall be as specified in these Plans and/or these Standards. 8.Epoxy applications shall be applied as specified in CDOT Standard Specifications for Road and Bridge Construction. 9.All surfaces shall be thoroughly cleaned prior to installation of striping or markings. 10.All sign posts shall utilize break-away assemblies and fasteners per the Standards. 11.A field inspection of location and installation of all signs shall be performed by the City of Fort Collins Traffic Engineer. All discrepancies identified during the field inspection must be corrected before the 2-year warranty period will begin. 12.The Developer installing signs shall be responsible for locating and protecting all underground utilities. 13.Special care shall be taken in sign location to ensure an unobstructed view of each sign. 14.Signage and striping has been determined by information available at the time of review. Prior to initiation of the warranty period,the City of Fort Collins Traffic Engineer reserves the right to require additional signage and/or striping if the City of Fort Collins Traffic Engineer determines that an unforeseen condition warrants such signage according to the MUTCD or the CDOT M and S Standards. All signage and striping shall fall under the requirements of the 2-year warranty period for new construction (except fair wear on traffic markings). 15.Sleeves for sign posts shall be required for use in islands/medians. Refer to Chapter 14, Traffic Control Devices, for additional detail. D. Storm Drainage Notes 1.The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 2.All recommendations of the Preliminary Drainage Report, dated July 22, 2020 by Northern Engineering Services, Inc., shall be followed and implemented. 3.Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must by submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall by submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. E. Water and Sewer Notes 1.All water and sanitary sewer construction shall be performed according to the Fort Collins-Loveland Water District and the South Fort Collins Sanitation District Standards and Specifications. 2.Construction of water and sewer facilities require a precon meeting with district operations staff prior to construction. 3.Contractor shall notify district inspectors prior to starting work. 4.Contractor shall contact the Sanitation District for sewer inspection 48 hours prior to connecting to existing sewer stubs. 5.All commercial domestic services require a reduced pressure backflow prevention device. 6.All water line shall be a minimum of (5) five feet and a maximum of (6) six feet below final grade. 7.All District valves shall be operate by District staff only. 8.Pipe pressure and vacuum testing shall be witnessed by District Inspectors. Waterline bacteria tests shall also be taken by District Inspectors. 9.Once the system is operational and all tests have passed, contractor shall request substantial completion with a letter to the district that includes the dollar value of the water and sewer improvements listed separately. 10.As-builts shall be submitted in pdf and dwg to the District for Final Approval. 11.If groundwater is encountered within depth of sewer construction, manholes must be water-proofed. CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R VAULT ELEC HY D VAULT ELEC GAS S VAULT ELEC FES CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR LID HY DCONTROL IRR CONTROL IRR CONTROL IRRXX W W WXXXXX XXXXXXX X X X X X X X X X X X X XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXEEG G G G G G G G GGGGGGGW W W WWWXSSSSSS SS XXX X X X X X X X X X X X X X XXXXXXXXXXXX X PARCEL X WILLOW BROOK PARCEL W WILLOW BROOK PARCEL R WILLOW BROOK POUDRE R-1 SCHOOL DISTRICT PARCEL NO. 8604000904 EXISTING SAN MH RIM=4903.86 INV IN=4891.42 (N) INV OUT=4891.22 (E) EXISTING 16" ADS FL=4901.13 EXISTING CONCRETE PAD TO BE REMOVED EXISTING HYDRANT TO BE RELOCATED FND NAIL & BRASS TAG, PLS 33193 FND NAIL & BRASS TAG, PLS 33193 FND NAIL & BRASS TAG, PLS 33193 FND #4 REBAR W/YPC, PLS 33193 FND #4 REBAR W/YPC, PLS 33193 FND NAIL & BRASS TAG, W.C., ILLEGIBLE EXISTING IRRIGATION DITCH ECLIPSE LANE (51' PUBLIC ROW)QUASAR WAY(51' PUBLIC ROW)FULL MOON DRIVE EXISTING ASPHALT TO BE REMOVED PROPOSED SAWCUT EXISTING STOP FULL MOON DR QUASAR WAY EXISTING BARRICADE TO BE REMOVED PORTION OF EXISTING FENCE TO BE REMOVED (COORDINATE W/ TRAIL/SIDEWALK CONNECTION) DRIP LINE DRIP LINE EXISTING TREE COORDINATE RAMP LOCATION WITH FORESTRY DEPARTMENT TO SAVE TREE REMOVE EXISTING RAMP EXISTING SIDEWALK TO BE REPLACED AS REQUIRED COORDINATE FENCE REMOVAL WITH ROADWAY KEYMAP KECHTER RD (C.R. 36)QUASARWAYEX1 DEMOLITION PLANEXISTING CONDITIONS &3 NORTH ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 EX1 EX2 SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 35 MATCH LINE - SEE SHEET EX2 EXISTING ELECTRIC E LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING IRRIGATION BOX EXISTING GAS METER EXISTING TELEPHONE PEDESTAL EXISTING TREES (TO REMAIN) FIELD SURVEY BY: NOTES: EXISTING SANITARY SEWER SS EXISTING WATER W EXISTING FENCE X EXISTING WATER METER EXISTING FIRE HYDRANT EXISTING ELECTRIC VAULT PROJECT BOUNDARY EXISTING RIGHT-OF-WAY EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR VAULT ELEC CONTROL IRR EXISTING TREES (TO BE REMOVED) EXISTING CABLE CTV EXISTING FIBER OPTIC FO 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL, REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL. 3.CONTRACTOR IS ENCOURAGED TO PERFORM DEMOLITION IN A MANNER THAT MAXIMIZES SALVAGE, RE-USE, AND RECYCLING OF MATERIALS. THIS INCLUDES APPROPRIATE SORTING AND STORING. IN PARTICULAR, DEMOLISHED CONCRETE, ASPHALT, AND BASE COURSE SHOULD BE RECYCLED IF POSSIBLE. 4.ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5.CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING SITE SURVEY. EXISTING OVERHEAD UTILITY OHE Original Field Survey Northern Engineering Services, Inc. Project Number: 1664-003 Date: June, 2020 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R S VAULT ELEC ARV H2O AR VH2O W FES D S S D W S O E VAULT ELEC TTTTT CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTVTTTTTTTT E E E E E EEEEEEEXXXXXXXXXXXXXXXXX XXXXXXXXXXXE E E E E X X X X X X X X X X X X X X X X X X X X XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXSTSTST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST STSTSTST SSSSSS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SSSSSSC T V CTV CTV CTV CTV CTV CTV CTV CTV XXXXXELEC WWWWWWWWWWWWWWWWWWWWWWWWWWPARCEL X WILLOW BROOK CITY OF FORT COLLINS PARCEL NO. 8609128901 EXISTING 18" PVC EXISTING 24" PVCEXISTING 402.9 LF 24" PVC @ 0.19% EXISTING 18" RCP EXISTING 376.6 LF 18" RCP @ 0.53% EXISTING CONCRETE PAD TO BE REMOVED POUDRE R-1 SCHOOL DISTRICT PARCEL NO. 8604000904 EXISTING SAN MH RIM=4896.98 INV IN=4877.84 (W) INV OUT=4877.78 (SE) EXISTING SAN MH RIM=4897.39 INV IN=4877.69 (NW) INV IN=4877.79 (E) INV OUT=4877.59 (S) EXISTING 69.0 LF 24" PVC @ 0.13% EXISTING SAN MH RIM=4898.92 INV IN=4878.72 (E) INV OUT=4878.57 (W) FL=4899.09 FL=4891.67 EXISTING INLET GRATE=4902.05 INV IN=4898.56 (N) INV OUT=4893.62 (E) EXISTING 10.5 LF 18" RCP @ 5.05% EXISTING STORM MH RIM=4898.51 INV IN=4891.06 (NE) INV OUT=4891.00 (W) EXISTING 69.0 LF 18" RCP @ 0.88% EXISTING STORM MH RIM=4897.11 INV IN=4889.02 (E) INV OUT=4888.97 (S) EXISTING GATE TO BE REMOVED EXISTING GATE TO BE REMOVED EXISTING GATE TO BE REMOVED EXISTING GATE TO BE REMOVED EXISTING GATE TO BE REMOVED EXISTING 1 STORY WOOD SHED TO BE REMOVED EXISTING 1 STORY WOOD SHED TO BE REMOVED EXISTING CONCRETE PAD TO BE REMOVED EXISTING FENCE TO BE REMOVED EXISTING FENCE TO BE REMOVED EXISTING FENCE TO BE REMOVED EXISTING FENCE TO BE REMOVED EXISTING WOOD GAZEBO TO BE REMOVED EXISTING AIR RELEASE VALVE TO BE REMOVED EXISTING AIR RELEASE VALVE PROTECTED BY WOOD POSTS TO BE REMOVED EXISTING OVERHEAD LIGHT TO BE REMOVED EXISTING OVERHEAD LIGHT TO BE REMOVED EXISTING GRAVEL DRIVE TO BE REMOVED EXISTING TELEPHONE TO BE REMOVED EXISTING TELEPHONE TO BE REMOVED EXISTING ELECTRIC TO BE REMOVED EXISTING WATER SHUT OFF TO BE REMOVED REFERENCE MONUMENT FND 2 1/2" ALUM. CAP ON #6 REBAR IN MONUMENT BOX REFERENCE MONUMENT FND 2 1/2" ALUM. CAP ON #6 REBAR IN MONUMENT BOX REFERENCE MONUMENT FND 2 1/2" ALUM. CAP ON #6 REBAR IN MONUMENT BOX EXISTING IRRIGATION DITCH EXISTING 1 STORY METAL FRAMED GARAGE TO BE REMOVED EXISTING 2 STORY WOOD HOME W/CRAWL SPACE 15' UTILITY EASEMENT REC. NO. 20190009470 EXISTING LIGHT TO BE RELOCATED SECTION LINE KECHTER ROAD (C.R. 36) (70' PUBLIC ROW) SAWCUT & REMOVE ASPHALT PAVEMENT SAWCUT & REMOVE 4.5' SIDEWALK SAWCUT & REMOVE ASPHALT PAVEMENT SAWCUT & REMOVE 4.5' SIDEWALK EXISTING GRAVEL DRIVE TO BE REMOVED REPLACE CURB AND GUTTER ON KECHTER EXISTING DRIP LINE EXISTING TREE TO BE REMOVED EX2 DEMOLITION PLANEXISTING CONDITIONS &4 NORTH ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 EX1 EX2 KEYMAP KECHTER RD (C.R. 36)QUASARWAYSheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 35 MATCH LINE - SEE SHEET EX1 EXISTING ELECTRIC E LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING IRRIGATION BOX EXISTING GAS METER EXISTING TELEPHONE PEDESTAL EXISTING TREES (TO REMAIN) FIELD SURVEY BY: NOTES: EXISTING SANITARY SEWER SS EXISTING WATER W EXISTING FENCE X EXISTING WATER METER EXISTING FIRE HYDRANT EXISTING ELECTRIC VAULT PROJECT BOUNDARY EXISTING RIGHT-OF-WAY EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR VAULT ELEC CONTROL IRR EXISTING TREES (TO BE REMOVED) EXISTING CABLE CTV EXISTING FIBER OPTIC FO 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL, REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL. 3.CONTRACTOR IS ENCOURAGED TO PERFORM DEMOLITION IN A MANNER THAT MAXIMIZES SALVAGE, RE-USE, AND RECYCLING OF MATERIALS. THIS INCLUDES APPROPRIATE SORTING AND STORING. IN PARTICULAR, DEMOLISHED CONCRETE, ASPHALT, AND BASE COURSE SHOULD BE RECYCLED IF POSSIBLE. 4.ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5.CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING SITE SURVEY. EXISTING OVERHEAD UTILITY OHE Original Field Survey Northern Engineering Services, Inc. Project Number: 1664-003 Date: June, 2020 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R XXXXXXXXXXXXXXXXXX X X X X X X X X X X X X X XXXXXXXXXXX4.5' SIDEWALK 4.5' SIDEWALK DRIVE-OVER CURB / GUTTER ADA CURB RAMP ADA CURB RAMP 6' VALLEY PAN DRIVE-OVER CURB / GUTTER DRIVE-OVER CURB / GUTTER ADA CURB RAMP DRIVE-OVER CURB / GUTTER PROPOSED 53' R.O.W. PROPOSED 53' R.O.W. PROPOSED 53' R.O.W. PROPOSED 61' R.O.W. PROPOSED 61' R.O.W. ~ASPHALT PAVEMENT~ END CONCRETE SIDEWALK ADJACENT GRADE TO BE FLUSH WITH WALK END CONCRETE SIDEWALK ADJACENT GRADE TO BE FLUSH WITH WALK ~ASPHALT PAVEMENT~~ASPHALT PAVEMENT~PARCEL X WILLOW BROOK PARCEL W WILLOW BROOK PARCEL R WILLOW BROOK POUDRE R-1 SCHOOL DISTRICT PARCEL NO. 8604000904 LOGGERS LANE ECLIPSE LANEQUASAR WAYWHEELHOUSE WAYCACTUS CURVECACTUS CURVE30' FL-FL 30' FL-FL 30' FL-FL~ASPHALT PAVEMENT~30' FL-FL FULL MOON DRIVE 4.5' SIDEWALK 4.5' SIDEWALK4.5' SIDEWALK 4.5' SIDEWALK4.5' SIDEWALK4.5' SIDEWALK 4.5' SIDEWALK4.5' SIDEWALK4.5' SIDEWALK4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK STOP SIGN END CONCRETE SIDEWALK, ADJACENT GRADE TO BE FLUSH WITH WALK COORDINATE RAMP LOCATION W/ FORESTRY TO PROTECT OR RELOCATE EXISTING TREE REMOVE EXISTING RAMP 2S 1S 2S 1S 1S 2S 2S 1S 1S 2S ADA CURB RAMP ADA CURB RAMP PV1 PAVING PLAN5 NORTH ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 35 KEYMAP KECHTER RD (C.R. 36)QUASARWAYPV1 PV2 EASEMENTS NOTES: 1.SEE DETAIL SHEETS FOR ADDITIONAL INFORMATION REGARDING CURBS AND PAVEMENT SECTIONS. 2.PAVEMENT MARKINGS SHALL BE PER CITY OF FORT COLLINS STANDARDS AND PROJECT SPECIFICATION MANUAL. 3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS. 4.ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. 5.ALL PUBLIC CONCRETE PAVING SHALL BE 6" THICK. 6.REFER TO SITE AND LANDSCAPE PLANS (BY OTHERS) FOR ADDITIONAL INFORMATION RELATED TO DECORATIVE PAVING, HARDSCAPES, AND OTHER SITE AMENITIES. PROPOSED VERTICAL CURB & GUTTER PROPERTY BOUNDARY EXISTING LOT LINE / / / / / / / /PROPOSED EDGE OF PAVEMENT ASPHALT PAVING PROPOSED OUTFALL VERTICAL CURB & GUTTER LEGEND: CONCRETE PAVING MATCH LINE - SEE SHEET PV2 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R PARKING NO ANY ITME PARKING NO ANY ITME PARKING NO ANY ITME SITE SIGN LEGEND 1S 2S 3S XXXXXXXXXXXXXXXXXXXXDRIVE-OVER CURB / GUTTER ADA CURB RAMP 6' VALLEY PAN ADA CURB RAMP DRIVE-OVER CURB / GUTTER ADA CURB RAMP 4.5' SIDEWALK 4.5' SIDEWALK DRIVE-OVER CURB / GUTTER CONCRETE T INTERSECTION CROSS PAN ADA CURB RAMP END CONCRETE SIDEWALK ADJACENT GRADE TO BE FLUSH WITH WALK END CONCRETE SIDEWALK ADJACENT GRADE TO BE FLUSH WITH WALK ~ASPHALT PAVEMENT~~ASPHALT PAVEMENT~~ASPHALT PAVEMENT~~ASPHALT PAVEMENT~PARCEL X WILLOW BROOK POUDRE R-1 SCHOOL DISTRICT PARCEL NO. 8604000904 CITY OF FORT COLLINS PARCEL NO. 8609128901 CACTUS CURVE WHEELHOUSE WAYWHEELHOUSE WAYCACTUS CURVEKECHTER ROAD (C.R. 36) (70' PUBLIC ROW) PROPOSED 53' R.O.W. 30' FL-FL 30' FL-FL PROPOSED 53' R.O.W. PROPOSED 61' R.O.W. 30' FL-FL 4.5' SIDEWALK4.5' SIDEWALK 4.5' SIDEWALK4.5' SIDEWALK4.5' SIDEWALK4.5' SIDEWALK4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK DRIVE-OVER CURB / GUTTER CLOSE EXISTING DRIVEWAY CLOSE EXISTING DRIVEWAY & ADD SIDEWALKSTOP SIGN STOP SIGN POND 1 RAIN GARDEN A RAIN GARDEN B 3S 2S 2S 1S 2S 1S 1S 2S 1S 1S 2S PV2 PAVING PLAN6 NORTH ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 35 KEYMAP KECHTER RD (C.R. 36)QUASARWAYPV1 PV2 EASEMENTS NOTES: 1.SEE DETAIL SHEETS FOR ADDITIONAL INFORMATION REGARDING CURBS AND PAVEMENT SECTIONS. 2.PAVEMENT MARKINGS SHALL BE PER CITY OF FORT COLLINS STANDARDS AND PROJECT SPECIFICATION MANUAL. 3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS. 4.ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. 5.ALL PUBLIC CONCRETE PAVING SHALL BE 6" THICK. 6.REFER TO SITE AND LANDSCAPE PLANS (BY OTHERS) FOR ADDITIONAL INFORMATION RELATED TO DECORATIVE PAVING, HARDSCAPES, AND OTHER SITE AMENITIES. PROPOSED VERTICAL CURB & GUTTER PROPERTY BOUNDARY EXISTING LOT LINE / / / / / / / /PROPOSED EDGE OF PAVEMENT ASPHALT PAVING PROPOSED OUTFALL VERTICAL CURB & GUTTER LEGEND: CONCRETE PAVING MATCH LINE - SEE SHEET PV1 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R PARKING NO ANY ITME PARKING NO ANY ITME PARKING NO ANY ITME SITE SIGN LEGEND 1 2 3 TTTTGGGGGGGGGGGGGG G G G G G GGGGGGGGGGGGGGEEEEEETTEEEEEEE ETT T EEEEEEEEEEEEEEEEEEEEEEEEEE E EEE EEEEEEEEEEETE EE EEE EE EGGGGGG G GGG VAULT ELEC VAULT ELEC GAS S VAULT ELEC FES CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR LID S VAULT ELEC FE S D S S SS HY D CONTROL IRR CONTROL IRR CONTROL IRR D E VAULT ELEC T VAULT ELECCXGCTVTE EW W W W CTV CTV CTV CTV CTV CTV CTV CTV CTVTT E E E E XXXXXXXXXXE EX EG G G GGGGWW STST ST ST ST ST ST ST ST ST STSSSS SS SS SS SS SS SS SS SS SS SS SS SSSS SS SSSSSS CTV CTV CTV CTV XX X X X X X X XXXXXXELEC WWWWWWWWWWWWWWW15' UTILITY EASEMENT REC. NO. 20190009470 FL=4899.09 FL=4891.67 INLET GRATE=4902.05 INV IN=4898.56 (N) INV OUT=4893.62 (E) 10.5 LF 18" RCP @ 5.05% STORM MH RIM=4898.51 INV IN=4891.06 (NE) INV OUT=4891.00 (W) 69.0 LF 18" RCP @ 0.88% STORM MH RIM=4897.11 INV IN=4889.02 (E) INV OUT=4888.97 (S) SAN MH RIM=4900.42 INV OUT=4886.72 (E) SAN MH RIM=4899.98 INV IN=4886.44 (W) INV IN=4886.34 (S) INV OUT=4886.24 (E) 57.2 LF 8" PVC @ 0.49% 18" PVC SAN MH RIM=4896.98 INV IN=4877.84 (W) INV OUT=4877.78 (SE)24" PVCSAN MH RIM=4897.39 INV IN=4877.69 (NW) INV IN=4877.79 (E) INV OUT=4877.59 (S) 69.0 LF 24" PVC @ 0.13% SAN MH RIM=4898.92 INV IN=4878.72 (E) INV OUT=4878.57 (W) 402.9 LF 24" PVC @ 0.19% 18" RCP 376.6 LF 18" RCP @ 0.53% POUDRE R-1 SCHOOL DISTRICT PARCEL NO. 8604000904 CITY OF FORT COLLINS PARCEL NO. 8609128901 SAN MH RIM=4903.86 INV IN=4891.42 (N) INV OUT=4891.22 (E) 16" ADS FL=4901.13 KECHTER ROAD (C.R. 36) (70' PUBLIC ROW) PARCEL X WILLOW BROOK PARCEL W WILLOW BROOK PARCEL R WILLOW BROOK FULL MOON DRIVE PROPOSED 8" SANITARYPROPOSED 8" WATERPROPOSED 8" SANITARYPROPOSED 8" WATERPROPOSED 8" WATERPROPOSED 8" WATERPROPOSED 8" WATER PROPOSED 8" SANITARY LOGGERS LANE (53' PUBLIC ROW)24" PVCQUASAR WAY(53' PUBLIC ROW)CACTUS CURVE(53' PUBLIC ROW)CACTUS CURVE (53' PUBLIC ROW)WHEELHOUSE WAY(53' PUBLIC ROW)RAIN GARDEN B RAIN GARDEN A POND 1 PROPOSED FIRE HYDRANT RELOCATION PROPOSED FIRE HYDRANT #1 PROPOSED FIRE HYDRANT #2 EX FIRE HYDRANT SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 35 OU1 OVERALL UTILITY PLAN7 NORTH ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 KEYMAP KECHTER RD (C.R. 36)QUASARWAYU1 U2 NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL WATER CONSTRUCTION SHALL BE PER FORT COLLINS - LOVELAND WATER DISTRICT, LATEST EDITION, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR AS REQUIRED FOR ABNORMAL DEFLECTIONS. 3.ALL SEWER CONSTRUCTION SHALL BE PER SOUTH FORT COLLINS SANITATION DISTRICT SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST EDITION. 4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5.ALL WATERLINES SHALL HAVE A 5-FT MINIMUM AND 6-FT MAXIMUM WATER LINE COVER FROM FINISHED GRADE TO TOP OF PIPE. 6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS. 10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 11.ALL INDIVIDUAL WATER SERVICES SHALL BE 3/4". ALL DUAL WATER SERVICES SHALL BE 1" BETWEEN THE TAP ON THE MAIN AND THE BRANCH YOLK IN THE METER PIT. EXISTING LOT LINE EASEMENT LINE SPROPOSED SEWER SERVICE WPROPOSED WATER SERVICE EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT W SS PROPOSED LOT LINE PROPOSED ROW EXISTING ROW EXISTING CABLE CTV PROPOSED WATER METER PIT CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R TTTTGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGEEEEEEEEEEEETE TEEEEEEEEEEEEEE E EEEE E E EEEEEE E EE E EEEEEE E E EEE GGGGG GGG GGGGGG G C/O C/O VAULT ELEC VAULT ELEC GAS S VAULT ELEC FES CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR LID HY DCONTROL IRR CONTROL IRR CONTROL IRRXX W W WXXXXX XXXXXXXXEEG G G G G G G G GGGGGGGW W W WWWSSSSSS SS XXX X X X X X X X X X X X X X XXXXXXXXXXXPOUDRE R-1 SCHOOL DISTRICT PARCEL NO. 8604000904 W W W W S S S WWS SWW W W W W WWWWWWWWWW W W W W W W W 12" RCP18" RCP 12" PVCPROPOSED TEE W/ 3-WAY VALVING (TYP.) PROPOSED 45° BEND (TYP.) PR SSMH A1-1 CONNECT TO EX WATER MAIN TAPPING SLEEVE W/ 8" GV (N) PROPOSED 45° BEND (TYP.) RELOCATED FIRE HYDRANT PR SSMH A3 PROPOSED TRANSFORMER PROPOSED TRANSFORMER APPROXIMATE GAS LOCATION APPROXIMATE GAS LOCATION APPROXIMATE LOCATION OF CONNECTION TO EX GAS 4.5' SIDEWALK 4.5' SIDEWALK4.5' SIDEWALKPROPOSED 8" SANITARYPROPOSED 8" WATERPROPOSED 8" SANITARYPROPOSED 8" WATERPROPOSED 8" WATERPROPOSED 8" WATER4.5' SIDEWALK 6' UTILITY & DRAINAGE EASEMENT 4.5' SIDEWALK 4.5' SIDEWALK4.5' SIDEWALK4.5' SIDEWALK 30' FL-FL 53' R.O.W. 30' FL-FL 53' R.O.W.4.5' SIDEWALK9' UTILITY EASEMENT 9' UTILITY EASEMENT 14' DRAINAGE EASEMENT 6' DRAINAGE EASEMENT ECLIPSE LANE (53' PUBLIC ROW)QUASAR WAY(53' PUBLIC ROW)SAN MH RIM=4903.86 INV IN=4891.42 (N) INV OUT=4891.22 (E) 16" ADS FL=4901.13 14' DRAINAGE EASEMENT 7' ACCESS EASEMENT 4.5' SIDEWALKWHEELHOUSE WAY(53' PUBLIC ROW)LOGGERS LANE (53' PUBLIC ROW)CACTUS CURVE(53' PUBLIC ROW)9' UTILITY EASEMENT PROPOSED WATER METER PIT (TYP.) APPROXIMATE LOCATION OF CONNECTION TO EX GAS PROPOSED FIRE HYDRANT #1 PROPOSED TRANSFORMER PROPOSED TRANSFORMER PROPOSED TRANSFORMER 12" PVCW S W W PROPOSED TRANSFORMER PROPOSED WATER METER PIT (TYP.) PROPOSED WATER METER PIT (TYP.) PROPOSED WATER METER PIT (TYP.) W W W W W W 9' UTILITY EASEMENT 12" RCP 12" PVC12" PVC12" PVCSTORM DRAIN LINE A SEE SHEET ST1 STORM DRAIN LINE B SEE SHEET ST2 STORM DRAIN LINE G SEE SHEET ST2 SANITARY LINE A-1 SEE SHEET SS1 PROPOSED LIGHT PROPOSED LIGHT PROPOSED LIGHT PROPOSED LIGHT W W WW SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 35 U1 UTILITY PLAN8 NORTH ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 KEYMAP KECHTER RD (C.R. 36)QUASARWAYU1 U2 NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL WATER CONSTRUCTION SHALL BE PER FORT COLLINS - LOVELAND WATER DISTRICT, LATEST EDITION, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR AS REQUIRED FOR ABNORMAL DEFLECTIONS. 3.ALL SEWER CONSTRUCTION SHALL BE PER SOUTH FORT COLLINS SANITATION DISTRICT SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST EDITION. 4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5.ALL WATERLINES SHALL HAVE A 5-FT MINIMUM AND 6-FT MAXIMUM WATER LINE COVER FROM FINISHED GRADE TO TOP OF PIPE. 6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS. 10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 11.ALL INDIVIDUAL WATER SERVICES SHALL BE 3/4". ALL DUAL WATER SERVICES SHALL BE 1" BETWEEN THE TAP ON THE MAIN AND THE BRANCH YOLK IN THE METER PIT. EXISTING LOT LINE EASEMENT LINE SPROPOSED SEWER SERVICE WPROPOSED WATER SERVICE EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT W SS PROPOSED LOT LINE PROPOSED ROW EXISTING ROW EXISTING CABLE CTV PROPOSED WATER METER PIT MATCH LINE - SEE SHEET U2 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R TGGGGGGGGGGGG G G G G G G G G G G G GGGGGGGGGGGTEEEETT T EEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE E E EEE E EEEEEEEEEEEEEEEEEEEEEEETE EEE EEEEE EEE EEGGGGGGGGGGG GGG G G S VAULT ELEC W FES D S S D E VAULT ELEC T CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTVTTTTT E E E E E E E EXXXXXXXXXXXX XXXE E E E E STSTST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST STSTSTST SSSSSS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SSSSSSC T V CTV CTV CTV CTV CTV CTV CTV CTV XXXXXELEC WWWWWWWWWWWWWWWWWWWWWWWWWW15' UTILITY EASEMENT REC. NO. 20190009470 FL=4899.09 FL=4891.67 INLET GRATE=4902.05 INV IN=4898.56 (N) INV OUT=4893.62 (E) 10.5 LF 18" RCP @ 5.05% STORM MH RIM=4898.51 INV IN=4891.06 (NE) INV OUT=4891.00 (W) 69.0 LF 18" RCP @ 0.88% STORM MH RIM=4897.11 INV IN=4889.02 (E) INV OUT=4888.97 (S) 18" PVC SAN MH RIM=4896.98 INV IN=4877.84 (W) INV OUT=4877.78 (SE)24" PVCSAN MH RIM=4897.39 INV IN=4877.69 (NW) INV IN=4877.79 (E) INV OUT=4877.59 (S) 69.0 LF 24" PVC @ 0.13% SAN MH RIM=4898.92 INV IN=4878.72 (E) INV OUT=4878.57 (W) 402.9 LF 24" PVC @ 0.19% 18" RCP 376.6 LF 18" RCP @ 0.53% POUDRE R-1 SCHOOL DISTRICT PARCEL NO. 8604000904 W W W W W W W W W W W W W W W S S S S W W S W S W W W W W W W W W CITY OF FORT COLLINS PARCEL NO. 860912890115" RCP12" PVC15" RCP15" RCP15" RCP PR SANITARY SEWER CONNECTION (TYP.) PR WATER SERVICE CONNECTION (TYP.) PR FIRE HYDRANT #2 PR TEE W/ 3-WAY VALVING (TYP.) PR SSMH A1 PROPOSED SSMH A (CONNECT TO EX SAN MAIN) PROPOSED STORM MH (CONNECT TO EX STORM MAIN) PR SSMH A2 PR 45° BEND (TYP.) PR TRANSFORMER PROPOSED TRANSFORMER APPROXIMATE GAS LOCATION APPROXIMATE GAS LOCATION APPROXIMATE GAS LOCATION PROPOSED 8" WATER PROPOSED 8" SANITARY4.5' SIDEWALK4.5' SIDEWALK4.5' SIDEWALK 30' FL-FL 53' R.O.W. 30' FL-FL 53' R.O.W.4.5' SIDEWALK9' UTILITY EASEMENT 9' UTILITY EASEMENT CACTUS CURVE(53' PUBLIC ROW)CACTUS CURVE (53' PUBLIC ROW)WHEELHOUSE WAY(53' PUBLIC ROW)14' DRAINAGE EASEMENT 7' ACCESS EASEMENT 4.5' SIDEWALK4.5' SIDEWALK4.5' SIDEWALK 4.5' SIDEWALK 9' UTILITY EASEMENT POND 1 9' UTILITY EASEMENT 9' UTILITY EASEMENT RAIN GARDEN A KECHTER ROAD (C.R. 36) (70' PUBLIC ROW) 9' UTILITY EASEMENT PROPOSED WATER METER PIT (TYP.) CONNECT TO EX WATER MAIN W/ TAPPING SLEEVE AND VALVE RAIN GARDEN B PROPOSED TRANSFORMER PROPOSED TRANSFORMER PROPOSED TRANSFORMER 12" PVC12" PVCW W W S 9' UTILITY EASEMENT PROPOSED WATER METER PIT (TYP.) PROPOSED WATER METER PIT (TYP.) CURB INLET 12" RC P 18" R C P 12" PVC12" PVC12" RCPSIDEWALK CHASE SIDEWALK CHASE STORM DRAIN LINE C SEE SHEET ST3 STORM DRAIN LINE D SEE SHEET ST3 STORM DRAIN LINE E SEE SHEET ST3 STORM DRAIN LINE F SEE SHEET ST3 SANTARY LINE A-2 SEE SHEET SS2 SANITARY LINE A-1 SEE SHEET SS1 STORM DRAIN LINE B SEE SHEET ST2 PROPOSED LIGHT PROPOSED LIGHT PROPOSED LIGHT PROPOSED LIGHT PROPOSED LIGHT CURB INLET IRRIGATION SERVICE W W SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 35 U2 UTILITY PLAN9 NORTH ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 KEYMAP KECHTER RD (C.R. 36)QUASARWAYU1 U2 NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL WATER CONSTRUCTION SHALL BE PER FORT COLLINS - LOVELAND WATER DISTRICT, LATEST EDITION, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR AS REQUIRED FOR ABNORMAL DEFLECTIONS. 3.ALL SEWER CONSTRUCTION SHALL BE PER SOUTH FORT COLLINS SANITATION DISTRICT SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST EDITION. 4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5.ALL WATERLINES SHALL HAVE A 5-FT MINIMUM AND 6-FT MAXIMUM WATER LINE COVER FROM FINISHED GRADE TO TOP OF PIPE. 6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS. 10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 11.ALL INDIVIDUAL WATER SERVICES SHALL BE 3/4". ALL DUAL WATER SERVICES SHALL BE 1" BETWEEN THE TAP ON THE MAIN AND THE BRANCH YOLK IN THE METER PIT. EXISTING LOT LINE EASEMENT LINE SPROPOSED SEWER SERVICE WPROPOSED WATER SERVICE EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT W SS PROPOSED LOT LINE PROPOSED ROW EXISTING ROW EXISTING CABLE CTV PROPOSED WATER METER PIT MATCH LINE - SEE SHEET U1 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R TTT TG G GGG G G G G G G G G G G G G GGGGGGGGGGGGGGGGGGGGGGGGGGEEEEEEEET ETEEEEEEEEEEETTTEEEEEEEEEEEEEEEEEEEEEEEEEE E E E E E EEEEEE E E E T EEEEEEEEEEG G G GGG GGGGGGGC/OC/OGASSCONTROLIRRCONTROLIRRWETTTCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVT T TTEEEE E EEEEGGGGGGG G WWWWSTSTSTSTSTSTSTSTSTSTSTSSSSSSSSSSSSSSSSSSSSSSSSCTVCTVCTVCTVCTVXXXXXXXXELECWWWWWWWWWW181.68 LF 8" PVC @ 2.70% 335.93 LF 8" PVC @ 1.50% SSMH A STA 10+00.00 N: 102553.08 E: 213403.65 SSMH A1 STA 11+81.68 N: 102734.69 E: 213398.76 SSMH A1-1 STA 15+17.61 N: 103070.50 E: 213389.71 SSMH A3 STA 15+11.21 N: 103078.09 E: 213561.84 338.89 LF 8" PVC @ 1.00% SSMH A2 STA 11+72.33 N: 102739.33 E: 213571.02 LOGGERS LANECACTUS CURVEWHEELHOUSE WAY QUASAR WAY CACTUS CURVE KECHTER ROAD (C.R. 36)(70' PUBLIC ROW)PARCEL W WILLOW BROOK PARCEL R WILLOW BROOK STORM DRAIN LINE A SEE SHEET ST1 STORM DRAIN LINE B SEE SHEET ST2 STORM DRAIN LINE C SEE SHEET ST3 STORM DRAIN LINE D SEE SHEET ST3 STORM DRAIN LINE E SEE SHEET ST3 STORM DRAIN LINE F SEE SHEET ST3 30' FL-FL53' ROW STORM DRAIN LINE G SEE SHEET ST2 SANTARY LINE A-2 SEE SHEET SS2 7 ACCESS EASEMENT 9 UTILITY EASEMENT 9 UTILITY EASEMENT 9 UTILITY EASEMENT 9 UTILITY EASEMENT 14 DRAINAGE EASEMENT 30' FL-FL53' ROW 15 UTILITY EASEMENT REC. NO. 20190009470 172.33 LF 8" PVC @ 1.00%RAIN GARDEN B POND 1 RAIN GARDEN A APPROXIMATE LIMITS OF ASPHALT PATCH CLEANOUT AT BEND IN SAN SVC (TYP.) CLEANOUT AT BEND IN SAN SVC (TYP.) 4870 4875 4880 4885 4890 4895 4900 4905 4910 4915 4870 4875 4880 4885 4890 4895 4900 4905 4910 4915 9+5010+0011+0012+0013+0014+0015+0016+00 SSMH A(DROP MH)STA 10+00.00RIM 4897.7±INV. IN 4886.71 (N)INV. IN 4877.97 (E)INV. IN 4878.96 (N)INV. OUT 4877.96 (W)SSMH A1STA 11+81.68RIM 4898.6±INV. IN 4891.81 (N)INV. IN 4891.81 (E)INV. OUT 4891.61 (S)SSMH A1-1STA 15+17.61RIM 4902.6±INV. OUT 4896.85 (S)181.68 LF 8 " P V C @ 2 . 7 0 % 335.93 LF 8" PVC @ 1 . 5 0 % STA.=10+80.39 INV.= 4891.88 15" RCP STORM 4897.344897.354897.574897.884898.204898.514898.824899.134899.444899.754900.074900.384900.694901.004901.314901.634901.944902.254902.55PROPOSED GROUND EXISTING GROUND 18" MIN. STA.=10+12.89 INV.= 4889.61 EX 18" RCP STORM STA.=10+22.30 EX CABLE STA.=10+27.82 EX CABLE STA.=13+33.32 PR ELECTRIC STA.=13+35.32 PR ELECTRIC STA.=15+40.21 DESCRIPTION STA.=15+54.90 DESCRIPTION DROP MH DROP INVERT IN = CENTERLINE OF INVERT OUT PROPOSED GROUND EXISTING GROUND 18" MIN. SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 35 SS1 PLAN & PROFILESANITARY LINE A10 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R KEYMAP KECHTER RD (C.R. 36)QUASARWAYNORTH ( IN FEET ) 1 inch = ft. Feet03030 30 60 90 SS1/SS2/SS3PROFILE SCALE: SANITARY LINE A1 EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL SANITARY CONSTRUCTION SHALL BE (LOCAL ENGINEERING STANDARD), LATEST EDITION. 3.MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 5.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL STROM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 6.ALL SINGLE-FAMILY SANITARY SEWER SERVICES TO BE 4" PVC. 7.ALL SANITARY MANHOLES TO BE 4'Ø UNLESS NOTED OTHERWISE. 8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. W EXISTING STORM SEWER SPROPOSED SEWER SERVICE EXISTING SANITARY SEWER SS PROPOSED AREA STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPOSED LOT LINE PROJECT BOUNDARY EXISTING RIGHT OF WAY W EASEMENT LINE PROPOSED RIGHT OF WAY PROPOSED COMBO STORM INLET PROPOSED TYPE-R STORM INLET PROPOSED WATER SERVICE SS1/SS2/SS3 TTT TG G GGG G G G G G G G G G G G G GGGGGGGGGGGGGGGGGGGGGGGGGGEEEEEEEET ETEEEEEEEEEEETTTEEEEEEEEEEEEEEEEEEEEEEEEEE E E E E E EEEEEE E E E T EEEEEEEEEEG G G GGG GGGGGGGC/OC/OGASSCONTROLIRRCONTROLIRRWETTTCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVT T TTEEEE E EEEEGGGGGGG G WWWWSTSTSTSTSTSTSTSTSTSTSTSSSSSSSSSSSSSSSSSSSSSSSSCTVCTVCTVCTVCTVXXXXXXXXELECWWWWWWWWWW181.68 LF 8" PVC @ 2.70% 335.93 LF 8" PVC @ 1.50% SSMH A STA 10+00.00 N: 102553.08 E: 213403.65 SSMH A1 STA 11+81.68 N: 102734.69 E: 213398.76 SSMH A1-1 STA 15+17.61 N: 103070.50 E: 213389.71 SSMH A3 STA 15+11.21 N: 103078.09 E: 213561.84 338.89 LF 8" PVC @ 1.00% SSMH A2 STA 11+72.33 N: 102739.33 E: 213571.02 LOGGERS LANECACTUS CURVEWHEELHOUSE WAY QUASAR WAY CACTUS CURVE KECHTER ROAD (C.R. 36)(70' PUBLIC ROW)PARCEL W WILLOW BROOK PARCEL R WILLOW BROOK STORM DRAIN LINE A SEE SHEET ST1 STORM DRAIN LINE B SEE SHEET ST2 STORM DRAIN LINE C SEE SHEET ST3 STORM DRAIN LINE D SEE SHEET ST3 STORM DRAIN LINE E SEE SHEET ST3 STORM DRAIN LINE F SEE SHEET ST3 30' FL-FL53' ROW STORM DRAIN LINE G SEE SHEET ST2 SANTARY LINE A-2 SEE SHEET SS2 7 ACCESS EASEMENT 9 UTILITY EASEMENT 9 UTILITY EASEMENT 9 UTILITY EASEMENT 9 UTILITY EASEMENT 14 DRAINAGE EASEMENT 30' FL-FL53' ROW 15 UTILITY EASEMENT REC. NO. 20190009470 172.33 LF 8" PVC @ 1.00%RAIN GARDEN B POND 1 RAIN GARDEN A APPROXIMATE LIMITS OF ASPHALT PATCH CLEANOUT AT BEND IN SAN SVC (TYP.) CLEANOUT AT BEND IN SAN SVC (TYP.) 4870 4875 4880 4885 4890 4895 4900 4905 4910 4915 4870 4875 4880 4885 4890 4895 4900 4905 4910 4915 9+5010+0011+0012+0013+0014+0015+0016+00 SSMH A1STA 11+81.68RIM 4898.6±INV. IN 4891.81 (N)INV. IN 4891.81 (E)INV. OUT 4891.61 (S)STA.=10+86.20 INV.= 4895.15 15" RCP STORM 172.33 LF 8" PVC @ 1.00%4898.594898.364898.584898.814899.034899.254899.424899.434899.754899.984900.194900.404900.624900.834901.054901.264901.484901.694901.914902.124902.23PROPOSED GROUND EXISTING GROUND 18" MIN.8" WATERSTA.=10+10.00TOP=4890.35STA.=13+23.94 PR ELECTRIC STA.=13+25.94 PR ELECTRIC 6" WATER (FH SERVICE)STA.=14+82.90TOP=4895.3018" MIN. PROPOSED GROUND EXISTING GROUND STA.=11+45.15 EX TELEPHONE (TO BE REMOVED) 18" MIN.SSMH A2STA 11+72.33RIM 4899.4±INV. IN 4893.74 (N)INV. OUT 4893.54 (W)SSMH A3STA 15+11.21RIM 4902.2±INV. OUT 4897.13 (S)338.89 LF 8" PVC @ 1.00% SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 35 SS2 PLAN & PROFILESANITARY LINE A11 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R KEYMAP KECHTER RD (C.R. 36)QUASARWAYNORTH ( IN FEET ) 1 inch = ft. Feet03030 30 60 90 SS1/SS2/SS3PROFILE SCALE: SANITARY LINE A-2 EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL SANITARY CONSTRUCTION SHALL BE (LOCAL ENGINEERING STANDARD), LATEST EDITION. 3.MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 5.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL STROM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 6.ALL SINGLE-FAMILY SANITARY SEWER SERVICES TO BE 4" PVC. 7.ALL SANITARY MANHOLES TO BE 4'Ø UNLESS NOTED OTHERWISE. 8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. W EXISTING STORM SEWER SPROPOSED SEWER SERVICE EXISTING SANITARY SEWER SS PROPOSED AREA STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPOSED LOT LINE PROJECT BOUNDARY EXISTING RIGHT OF WAY W EASEMENT LINE PROPOSED RIGHT OF WAY PROPOSED COMBO STORM INLET PROPOSED TYPE-R STORM INLET PROPOSED WATER SERVICE SS1/SS2/SS3 VAULTELECVAULTELECGASSVAULTELECCONTROLIRRCONTROLIRRWFESHYDCONTROLIRRCONTROLIRRCONTROLIRRDEVAULTELECTWTTCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVT T TTTEEEEE E EXXXX X X X X X X X X X X EEEEGGGGGGG G G WWWWSTSTSTSTSTSTSTSTSTSTSTSSSSSSSSSSSSSSSSSSSSSSSS SSCTVCTVCTVX XXXXXXX X X X X X X X X ELECWWWWWWWWWWWTT TG G GGGGGGGGGGGGGGGGGGGGGGGGGGEEEEEEEET ETEEETEEEEEEEEEEEEEEE E E E E E EEEEEE E E E T EEEEEEG G G GGG GGGGC/OLOGGERS LANEECLIPSELANECACTUS CURVEWHEELHOUSE WAY QUASAR WAY CACTUS CURVE KECHTER ROAD (C.R. 36)(70' PUBLIC ROW)PARCEL X WILLOW BROOK PARCEL W WILLOW BROOK PARCEL R WILLOW BROOK RAIN GARDEN BSTORM DRAIN LINE A SEE SHEET ST1 STORM DRAIN LINE B SEE SHEET ST2 STORM DRAIN LINE C SEE SHEET ST3 STORM DRAIN LINE D SEE SHEET ST3 STORM DRAIN LINE E SEE SHEET ST3 STORM DRAIN LINE F SEE SHEET ST3 30' FL-FL53' ROW STORM DRAIN LINE G SEE SHEET ST2 FES G2 STA 11+23.35 N: 103181.69 E: 213400.95 FES G-1 STA 10+20.00 N: 103179.74 E: 213504.28 103.35 LF12"x18" ELLIPTICAL RCP@ 0.05%A-6 STA 15+38.71 N: 103168.32 E: 213541.16 A-5 STA 14+35.84 N: 103165.11 E: 213643.99 A-4 STA 13+61.28 N: 103090.58 E: 213646.21 A-3 STA 12+84.89 N: 103014.21 E: 213648.05 A-2 STA 11+80.17 N: 102909.53 E: 213650.98 A-1 STA 10+37.70 N: 102767.12 E: 213654.81 FES A STA 10+20.00 N: 102756.73 E: 213640.48 102.88 LF 12" HDPE @ 0.50%74.56 LF 12" HDPE @ 0.50%76.39 LF 12" HDPE @ 0.50%104.72 LF 12" HDPE @ 0.50% 142.47 LF 12" HDPE @ 0.50% 17.70 LF 12" HDPE @ 0.50% B7 STA 13+76.95 N: 103046.26 E: 213476.56 B6 STA 13+25.92 N: 102995.25 E: 213477.93 B-5 STA 12+27.31 N: 102896.68 E: 213480.61 B-4 STA 11+95.47 N: 102864.85 E: 213481.47 B-3 STA 11+03.09 N: 102772.50 E: 213483.96 B-2 STA 10+82.59 N: 102752.01 E: 213484.52 B-1 STA 10+52.59 N: 102722.02 E: 213485.33 FES B STA 10+20.00 N: 102689.44 E: 213486.24 51.03 LF 12" HDPE @ 1.00%98.61 LF 12" HDPE @ 1.00% 31.84 LF 12" HDPE @ 1.00% 92.38 LF 12" HDPE @ 1.50% 20.50 LF 12" RCP @ 1.50% 30.00 LF 15" RCP @ 1.00% 32.59 LF 15" RCP @ 2.00% POND 1 SANTARY LINE A-2 SEE SHEET SS2 6 DRAINAGE & UTILITY EASEMENT 7 ACCESS EASEMENT 9 UTILITY EASEMENT 9 UTILITY EASEMENT 9 UTILITY EASEMENT 14 DRAINAGE EASEMENT 15 UTILITY EASEMENT REC. NO. 20190009470 D-1 STA 10+52.59 N: 102633.84 E: 213416.48 FES J STA 10+20.00 N: 103041.28 E: 213657.98 INV=4901.07 FES J-1 STA 10+37.27 N: 103058.54 E: 213657.39 INV=4901.06 17.27 LF 12" PVC @ -0.08% (FIELD FIT) East Property Line 4890 4895 4900 4905 4910 4915 4890 4895 4900 4905 4910 4915 9+5010+0011+0012+0013+0014+0015+0016+00 RAIN GARDEN B (BOT EL = 4896.4)FES ASTA 10+20.00INV. 4896.40A-1STA 10+37.70FL. EL 4901.0±INV. IN 4896.49 (N)INV. OUT 4896.49 (SW)PROPOSED GROUND EXISTING GROUNDA-2STA 11+80.17FL. EL 4901.0±INV. IN 4897.20 (N)INV. OUT 4897.20 (S)A-3STA 12+84.89FL. EL 4901.0±INV. IN 4897.72 (N)INV. OUT 4897.72 (S)A-4STA 13+61.28FL. EL 4901.0±INV. IN 4898.11 (N)INV. OUT 4898.11 (S)A-5STA 14+35.84FL. EL 4901.5±INV. IN 4898.49 (W)INV. OUT 4898.48 (S)A-6STA 15+38.71FL. EL 4901.0±INV. OUT 4899.00 (E)102.88 LF 12" HDPE @ 0.50%74.56 LF 12" HDPE @ 0.50%76.39 LF 12" HDPE @ 0.50%104.72 LF 12" HDPE @ 0.50% 142.47 LF 12" HDPE @ 0.50% 17.70 LF 12" HDPE @ 0.50%4896.404897.434901.254901.744902.244902.254902.234901.214901.484901.754901.754901.304901.624902.454902.034901.394901.954901.644901.994902.364901.914901.324902.07PROPOSED GROUND EXISTING GROUND ST1 PLAN & PROFILESTORM DRAIN A12 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NORTH ( IN FEET ) 1 inch = ft. Feet03030 30 60 90 PROFILE SCALE: STORM DRAIN LINE A KEYMAP KECHTER RD (C.R. 36)QUASARWAYSheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 35 EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: NOTES: W EXISTING SANITARY SEWER SS PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPOSED LOT LINE PROJECT BOUNDARY EXISTING RIGHT OF WAY EXISTING STORM SEWER EASEMENT LINE 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 3.PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF FLARED END SECTIONS. 4.ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY CITY OF FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). 5.CONTRACTOR SHALL SHALL CONFIRM THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR THEIR PROPOSED METHODS OF INSTALLATION (i.e., WITHIN PRE-CASTER'S TOLERANCES, ETC.). PROPOSED RIGHT OF WAY INLET SCHEDULE: INLET SCHEDULE NAME TYPE SIZE A-1 NYLOPLAST LIGHT DUTY W/ DROP-IN GRATE 15" A-2 NYLOPLAST IN-LINE DRAIN W/ DROP-IN GRATE 12" A-3 NYLOPLAST IN-LINE DRAIN W/ DROP-IN GRATE 12" A-4 NYLOPLAST IN-LINE DRAIN W/ DROP-IN GRATE 12" A-5 NYLOPLAST LIGHT DUTY W/ DROP-IN GRATE 15" A-6 NYLOPLAST IN-LINE DRAIN W/ DROP-IN GRATE 12" B-1 SINGLE CURB INLET (DETAIL D5-501)4'x3' B-2 SINGLE CURB INLET (DETAIL D5-501)4'x3' B-3 NYLOPLAST IN-LINE DRAIN W/ DROP-IN GRATE 12" B-4 NYLOPLAST IN-LINE DRAIN W/ DROP-IN GRATE 12" B-5 NYLOPLAST IN-LINE DRAIN W/ DROP-IN GRATE 12" B-6 NYLOPLAST IN-LINE DRAIN W/ DROP-IN GRATE 12" B-7 NYLOPLAST IN-LINE DRAIN W/ DROP-IN GRATE 12" C-1 WATER QUALITY OUTLET STRUCTURE (D6-601)24" D-1 SINGLE CURB INLET (DETAIL D5-501)4'x3' D-2 WATER QUALITY OUTLET STRUCTURE (D6-601)24" E-1 DOUBLE CURB INLET (DETAIL D5-500)7'-1"x3' F-1 STANDARD MANHOLE 48" ø F-2 EDB OUTLET STRUCTURE (DETAIL D6-601)9'-6"x4'-6"STORM DRAIN A Center Buildings 4890 4895 4900 4905 4910 4915 4890 4895 4900 4905 4910 4915 9+5010+0011+0012+0013+0014+0014+50 FES BSTA 10+20.00INV. 4891.64POND 1 (BOT EL = 4891.85)B-1STA 10+52.59FL. EL 4898.5±INV. IN 4895.00 (N)INV. OUT 4892.29 (S)B-2STA 10+82.59FL. EL 4898.9±INV. IN 4895.55 (N)INV. OUT 4895.30 (S)B-3STA 11+03.09FL. EL 4900.2±INV. IN 4895.86 (N)INV. OUT 4895.86 (S)B-4STA 11+95.47FL. EL 4900.4±INV. IN 4897.24 (N)INV. OUT 4897.24 (S)B-5STA 12+27.31FL. EL 4900.5±INV. IN 4897.56 (N)INV. OUT 4897.56 (S)B6STA 13+25.92FL. EL 4902.0±INV. IN 4898.55 (N)INV. OUT 4898.55 (S)B7STA 13+76.95FL. EL 4902.0±INV. OUT 4899.06 (S)51.03 LF 12" HDPE @ 1.00 % 98.61 LF 12" HDPE @ 1.00% 31.84 LF 12" HDPE @ 1.00% 92.38 LF 12" HDP E @ 1 . 5 0 % 20.50 LF 12" RCP @ 1.50% 30.00 LF 15" RCP @ 1.00% 32.59 LF 15" RCP @ 2.00% PROPOSED GROUND EXISTING GROUND STA.=10+67.59 INV.= 4892.68 PR SANITARY 18" MIN. STA.=10+48.09 PR ELECTRIC STA.=10+34.09 PR GAS PENETRATE POND WALL Eclipse Culvert 4890 4895 4900 4905 4910 4915 4890 4895 4900 4905 4910 4915 9+7510+0011+0011+50 103.35 LF 12"X18" ELIPTICAL RCP @ 0.05%FES G2STA 11+23.35INV. 4901.27STA.=10+40.59 PR GAS (TO BE LOWERED TO AVOID CONFLICT) STA.=11+00.16 PR GAS (TO BE LOWERED TO AVOID CONFLICT)8" WATERSTA.=10+81.24TOP=4897.50PROPOSED GROUND (ECLIPSE LANE CONNECTION) EXISTING GROUNDFES G-1STA 10+20.00INV. 4901.224891.544891.794898.954898.944899.904900.264900.324900.384900.514900.644902.404902.404902.374902.014902.384902.034904.144903.964904.02PROPOSED GROUND EXISTING GROUND PROPOSED GROUND EXISTING GROUND 8" WATER STA.=10+77.59 TOP=4893.50VAULTELECGASSVAULTELECFESCONTROLIRRCONTROLIRR SVAULTELECWDSTX TTCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVT T TEEEEEXEGGGGGGGGWWWW STSTSTSTSTSTSTSTSTSTSTSSSSSSSSSSSSSSSSSSSSSSSS SS SS SSCTV CTVCTVCTVCTVCTVXXXXXXXXELECWWWWWWWWWWTTT TG G GGG G G G G G G G G G G G G GGGGGGGGGGGGGGGGGGGGGGGGEEEEEEEET ETEEEEEEEEEEETTTEEEEEEEEEEEEEEEEEEEEEEEEEE E E E E E EEEEEE E E E T EEEEEEEEG G G G GGGGGGGC/OC/OLOGGERS LANECACTUS CURVEWHEELHOUSE WAY QUASAR WAY CACTUS CURVE KECHTER ROAD (C.R. 36)(70' PUBLIC ROW)PARCEL W WILLOW BROOK PARCEL R WILLOW BROOK STORM DRAIN LINE B SEE SHEET ST2 STORM DRAIN LINE C SEE SHEET ST3 STORM DRAIN LINE D SEE SHEET ST3 STORM DRAIN LINE E SEE SHEET ST3 STORM DRAIN LINE F SEE SHEET ST3 30' FL-FL53' ROW STORM DRAIN LINE G SEE SHEET ST2 FES G2 STA 11+23.35 N: 103181.69 E: 213400.95 FES G-1 STA 10+20.00 N: 103179.74 E: 213504.28 103.35 LF12"x18" ELLIPTICAL RCP@ 0.05%A-6 STA 15+38.71 N: 103168.32 E: 213541.16 102.88 LF 12" HDPE @ 0.50%B7 STA 13+76.95 N: 103046.26 E: 213476.56 B6 STA 13+25.92 N: 102995.25 E: 213477.93 B-5 STA 12+27.31 N: 102896.68 E: 213480.61 B-4 STA 11+95.47 N: 102864.85 E: 213481.47 B-3 STA 11+03.09 N: 102772.50 E: 213483.96 B-2 STA 10+82.59 N: 102752.01 E: 213484.52 B-1 STA 10+52.59 N: 102722.02 E: 213485.33 FES B STA 10+20.00 N: 102689.44 E: 213486.24 51.03 LF 12" HDPE @ 1.00%98.61 LF 12" HDPE @ 1.00% 31.84 LF 12" HDPE @ 1.00% 92.38 LF 12" HDPE @ 1.50% 20.50 LF 12" RCP @ 1.50% 30.00 LF 15" RCP @ 1.00% 32.59 LF 15" RCP @ 2.00% POND 1 SANTARY LINE A-2 SEE SHEET SS2 9 UTILITY EASEMENT7 ACCESS EASEMENT 9 UTILITY EASEMENT 9 UTILITY EASEMENT 9 UTILITY EASEMENT 14 DRAINAGE EASEMENT 6 DRAINAGE & UTILITY EASEMENT 15 UTILITY EASEMENT REC. NO. 20190009470 D-1 STA 10+52.59 N: 102633.84 E: 213416.48 PARCEL NO. 860400090412.50 LF 12" RCP @ 0.64% (FIELD FIT) FES I STA 10+20.00 N: 103038.12 E: 213305.58 INV=4900.57 FES I-1 STA 10+32.50 N: 103050.61 E: 213305.29 INV=4900.65 PROFILE SCALE: STORM DRAIN LINE B & G ST2 PLAN & PROFILESTORM DRAIN A13 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NORTH ( IN FEET ) 1 inch = ft. Feet03030 30 60 90 KEYMAP KECHTER RD (C.R. 36)QUASARWAYSheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 35 EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: NOTES: W EXISTING SANITARY SEWER SS PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPOSED LOT LINE PROJECT BOUNDARY EXISTING RIGHT OF WAY EXISTING STORM SEWER EASEMENT LINE 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 3.PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF FLARED END SECTIONS. 4.ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY CITY OF FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). 5.CONTRACTOR SHALL SHALL CONFIRM THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR THEIR PROPOSED METHODS OF INSTALLATION (i.e., WITHIN PRE-CASTER'S TOLERANCES, ETC.). PROPOSED RIGHT OF WAY INLET SCHEDULE: INLET SCHEDULE NAME TYPE SIZE A-1 NYLOPLAST LIGHT DUTY W/ DROP-IN GRATE 15" A-2 NYLOPLAST IN-LINE DRAIN W/ DROP-IN GRATE 12" A-3 NYLOPLAST IN-LINE DRAIN W/ DROP-IN GRATE 12" A-4 NYLOPLAST IN-LINE DRAIN W/ DROP-IN GRATE 12" A-5 NYLOPLAST LIGHT DUTY W/ DROP-IN GRATE 15" A-6 NYLOPLAST IN-LINE DRAIN W/ DROP-IN GRATE 12" B-1 SINGLE CURB INLET (DETAIL D5-501)4'x3' B-2 SINGLE CURB INLET (DETAIL D5-501)4'x3' B-3 NYLOPLAST IN-LINE DRAIN W/ DROP-IN GRATE 12" B-4 NYLOPLAST IN-LINE DRAIN W/ DROP-IN GRATE 12" B-5 NYLOPLAST IN-LINE DRAIN W/ DROP-IN GRATE 12" B-6 NYLOPLAST IN-LINE DRAIN W/ DROP-IN GRATE 12" B-7 NYLOPLAST IN-LINE DRAIN W/ DROP-IN GRATE 12" C-1 WATER QUALITY OUTLET STRUCTURE (D6-601)24" D-1 SINGLE CURB INLET (DETAIL D5-501)4'x3' D-2 WATER QUALITY OUTLET STRUCTURE (D6-601)24" E-1 DOUBLE CURB INLET (DETAIL D5-500)7'-1"x3' F-1 STANDARD MANHOLE 48" ø F-2 EDB OUTLET STRUCTURE (DETAIL D6-601)9'-6"x4'-6"STORM DRAIN BPROFILE SCALE: Rain Garden A Outfall 4880 4885 4890 4895 4900 4905 4910 4880 4885 4890 4895 4900 4905 4910 9+7510+0011+0011+50 Rain Garden B Outfall 4880 4885 4890 4895 4900 4905 4910 4880 4885 4890 4895 4900 4905 4910 9+75 10+00 11+00 11+50 Entrance Inlet East 4880 4885 4890 4895 4900 4905 4910 4880 4885 4890 4895 4900 4905 4910 9+7510+0011+00 Pond Outfall 4880 4885 4890 4895 4900 4905 4910 4880 4885 4890 4895 4900 4905 4910 9+75 10+00 11+00 STA.=10+79.52 EX TELEPHONE (TO BE REMOVED) POND 1 (BOT EL = 4891.85) PROPOSED GROUND EXISTING GROUND PENETRATE POND WALLFES CSTA 10+20.00INV. 4891.70C-1STA 11+18.70RIM 4897.3±INV. OUT 4892.69 (SW)RAIN GARDEN B (BOT EL = 4896.4) 98.70 LF 18" RCP @ 1.00% RAIN GARDEN A (BOT EL = 4894.0)D-2STA 11+09.04RIM 4895.1±INV. OUT 4892.09 (E)FES DSTA 10+20.00INV. 4891.4432.59 LF 15" RCP @ 0.50% POND 1 (BOT EL = 4891.85)8" WATERSTA.=10+57.59TOP=4889.94STA.=10+87.08 PR ELECTRIC STA.=10+48.09 PR ELECTRIC STA.=10+67.58 INV.= 4888.88 PR SANITARY FES ESTA 10+20.00INV. 4891.4034.38 LF 15" RCP @ 0.50%E-1STA 10+54.38FL. EL 4896.9±INV. OUT 4891.57 (E)POND 1 (BOT EL = 4891.85) PROPOSED GROUND EXISTING GROUND PENETRATE POND WALL STA.=10+49.71 PR ELECTRIC POND 1F-2STA 10+69.42RIM 4896.7±INV. IN 4891.25INV. OUT 4890.42 (S)49.42 LF 15" RCP @ 0.50%F-1STA 10+20.00RIM 4897.8±INV. IN 4890.17 (N)INV. IN 4889.97 (E)INV. OUT 4889.95 (W)4891.604891.804901.094901.244899.874896.404891.344891.594897.414897.234895.894894.004891.324891.624897.344897.974891.29STA.=10+28.31 EX CABLE STA.=10+38.61 EX ELECTRIC PROPOSED GROUND EXISTING GROUND PROPOSED GROUND EXISTING GROUND PROPOSED GROUND EXISTING GROUND PROPOSED GROUND EXISTING GROUND FLOW CONTROL GRATE ACCESS PENETRATE POND WALLD-1STA 10+52.59FL. EL 4897.0±INV. IN 4891.80 (W)INV. OUT 4891.60 (E)PROPOSED GROUND EXISTING GROUND S VAULT ELEC W FE SD S S D E VAULT ELEC TTT CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTVTTTTT E E E EEEEXXXXXXXEEE STST ST ST ST ST ST ST ST ST ST ST ST STSTSSSS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SSSSC T V CTV CTV CTV CTV CTV ELEC WWWWWWWWWWWWWWWWWWWWGGGGG G G G G G G G GGGGTT T EEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEETEE EGGGGG CACTUS CURVEWHEELHOUSE WAYKECHTER ROAD (C.R. 36) (70' PUBLIC ROW) PARCEL NO. 8604000904 PARCEL X WILLOW BROOKSTORM DRAIN LINE A SEE SHEET ST1 STORM DRAIN LINE B SEE SHEET ST2 STORM DRAIN LINE C SEE SHEET ST3 STORM DRAIN LINE D SEE SHEET ST3 STORM DRAIN LINE E SEE SHEET ST3 STORM DRAIN LINE F SEE SHEET ST3 30' FL-FL53' ROW C-1 STA 11+18.70 N: 102722.51 E: 213611.38 98.70 L F 1 8 " R C P @ 1. 0 0 % FES C STA 10+20.00 N: 102677.64 E: 213523.47FES D STA 10+20.00 N: 102634.72 E: 213449.05 D-2 STA 11+09.04 N: 102632.32 E: 213360.04 RAIN GARDEN B RAIN GARDEN B POND 1 32.59 LF 15" RCP @ 0.50% E-1 STA 10+54.38 N: 102613.97 E: 213417.02 FES E STA 10+20.00 N: 102624.34 E: 213449.80 34.38 LF 15" RCP @ 0.50%49.42 LF 15" RCP @ 0.50%F-1 STA 10+20.00 N: 102565.71 E: 213467.49 SANITARY LINE A-1 SEE SHEET SS1 14 DRAINAGE EASEMENT 9 UTILITY EASEMENT 9 UTILITY EASEMENT 9 UTILITY EASEMENT 9 UTILITY EASEMENT 9 UTILITY EASEMENT SIDEWALK CHASE SIDEWALK CHASE 6 DRAINAGE & EASEMENT 30' FL-FL 53' ROW 6 DRAINAGE & UTILITY EASEMENT 15 UTILITY EASEMENT REC. NO. 20190009470 APPROXIMATE LIMITS OF ASPHALT PATCH F-2 STA 10+69.42 N: 102615.10 E: 213469.04 56.46 LF 15" RCP @ 0.50% D-1 STA 10+52.59 N: 102633.84 E: 213416.48 PROFILE SCALE: STORM DRAIN LINE C, D, E & F ST3 PLAN & PROFILESTORM DRAIN A14 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NORTH ( IN FEET ) 1 inch = ft. Feet03030 30 60 90 KEYMAP KECHTER RD (C.R. 36)QUASARWAYSheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 35 EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: NOTES: W EXISTING SANITARY SEWER SS PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPOSED LOT LINE PROJECT BOUNDARY EXISTING RIGHT OF WAY EXISTING STORM SEWER EASEMENT LINE 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 3.PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF FLARED END SECTIONS. 4.ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY CITY OF FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). 5.CONTRACTOR SHALL SHALL CONFIRM THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR THEIR PROPOSED METHODS OF INSTALLATION (i.e., WITHIN PRE-CASTER'S TOLERANCES, ETC.). PROPOSED RIGHT OF WAY INLET SCHEDULE: INLET SCHEDULE NAME TYPE SIZE A-1 NYLOPLAST LIGHT DUTY W/ DROP-IN GRATE 15" A-2 NYLOPLAST IN-LINE DRAIN W/ DROP-IN GRATE 12" A-3 NYLOPLAST IN-LINE DRAIN W/ DROP-IN GRATE 12" A-4 NYLOPLAST IN-LINE DRAIN W/ DROP-IN GRATE 12" A-5 NYLOPLAST LIGHT DUTY W/ DROP-IN GRATE 15" A-6 NYLOPLAST IN-LINE DRAIN W/ DROP-IN GRATE 12" B-1 SINGLE CURB INLET (DETAIL D5-501)4'x3' B-2 SINGLE CURB INLET (DETAIL D5-501)4'x3' B-3 NYLOPLAST IN-LINE DRAIN W/ DROP-IN GRATE 12" B-4 NYLOPLAST IN-LINE DRAIN W/ DROP-IN GRATE 12" B-5 NYLOPLAST IN-LINE DRAIN W/ DROP-IN GRATE 12" B-6 NYLOPLAST IN-LINE DRAIN W/ DROP-IN GRATE 12" B-7 NYLOPLAST IN-LINE DRAIN W/ DROP-IN GRATE 12" C-1 WATER QUALITY OUTLET STRUCTURE (D6-601)24" D-1 SINGLE CURB INLET (DETAIL D5-501)4'x3' D-2 WATER QUALITY OUTLET STRUCTURE (D6-601)24" E-1 DOUBLE CURB INLET (DETAIL D5-500)7'-1"x3' F-1 STANDARD MANHOLE 48" ø F-2 EDB OUTLET STRUCTURE (DETAIL D6-601)9'-6"x4'-6" STORM DRAINS C, D & E PROFILE SCALE:PROFILE SCALE:PROFILE SCALE: TTT TG G GGG G G G G G G G G G G G G GGGGGGGGGGGGGGGGGGGGGGGGGGEEEEEEEET ETEEEEEEEEEEETTTEEEEEEEEEEEEEEEEEEEEEEEEEE E E E E E EEEEEE E E E T EEEEEEEEEEG G G GGG GGGGGGGC/OC/OGASSCONTROLIRRCONTROLIRRWETTTCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVT T TTEEEE E EEEEGGGGGGG G WWWWSTSTSTSTSTSTSTSTSTSTSTSSSSSSSSSSSSSSSSSSSSSSSSCTVCTVCTVCTVCTVXXXXXXXXELECWWWWWWWWWWLOGGERS LANECACTUS CURVEWHEELHOUSE WAY QUASAR WAY CACTUS CURVE KECHTER ROAD (C.R. 36)(70' PUBLIC ROW)PARCEL W WILLOW BROOK PARCEL R WILLOW BROOK STORM DRAIN LINE A SEE SHEET ST1 STORM DRAIN LINE B SEE SHEET ST2 STORM DRAIN LINE C SEE SHEET ST3 STORM DRAIN LINE D SEE SHEET ST3 STORM DRAIN LINE E SEE SHEET ST3 STORM DRAIN LINE F SEE SHEET ST3 STORM DRAIN LINE G SEE SHEET ST2 SANTARY LINE A-2 SEE SHEET SS2 7 ACCESS EASEMENT 9 UTILITY EASEMENT 9 UTILITY EASEMENT 9 UTILITY EASEMENT 9 UTILITY EASEMENT 14 DRAINAGE EASEMENT 15 UTILITY EASEMENT REC. NO. 20190009470 RAIN GARDEN B POND 1 RAIN GARDEN A PR FIRE HYDRANT #1 PR FIRE HYDRANT #2 APPROXIMATE LIMITS OF ASPAHLT PATCH CONNECT TO EX WATER MAIN TAPPING SLEEVE W/ 8" GV (N) (CONTRACTOR TO POTHOLE TO VERIFY DEPTH PRIOR TO CONSTRUCTION) N:102531.75 E:213414.22 RELOCATED EX FH CONNECT TO EX WATER MAIN TAPPING SLEEVE W/ 8" GV (N) (CONTRACTOR TO POTHOLE TO VERIFY DEPTH PRIOR TO CONSTRUCTION) N:103203.92 E:213443.72 STA. 15+43.46 45.00° BEND w/ TB N:103073.00 E:213404.65 STA. 20+09.69 45.00° BEND w/ TB N:102748.92 E:213555.75 STA. 15+78.60 8"x8" TEE w/ TB & 3-8" GVs N:103071.90 E:213439.76 STA. 11+60.75 8"x6" SWIVEL TEE w/ TB & 6" GV (E) N:102692.44 E:213409.91 STA. 12+13.28 8"x8" TEE w/ TB & 3-8" GVs N:102744.96 E:213408.49 6.87 LF 8" PVC N45°05'32"E 160.75 LF 8" PVC N01°32'18"W52.54 LF 8" PVC N01°32'39"W35.13 LF 8" PVCS88°12'34"E7.07 LF 8" PVC S43°27'08"W 147.31 LF 8" PVCS88°27'27"WSTA. 17+11.76 8"x6" SWIVEL TEE w/ TB & 6" GV (W) N:103044.81 E:213552.73 STA. 16+93.49 45.00° BEND w/ TB N:103063.07 E:213552.24 7.51 LF 8" PVC S43°12'34"E SANITARY LINE A-1 SEE SHEET SS1 IRRIGATION SERVICE STA. 17+35.52 8"x4" TEE w/ TB N:103021.07 E:213553.38 STA. 17+40.52 8"x4" TEE w/ TB N:103016.07 E:213553.51 STA. 18+77.80 8"x4" TEE w/ TB N:102878.84 E:213557.23 STA. 19+03.87 8"x4" TEE w/ TB N:102852.77 E:213557.94 STA. 16+47.51 8"x6" TEE w/ TB N:103069.75 E:213508.64 STA. 11+48.07 8"x6" SWIVEL TEE w/ TB & 6" GV (W) N:103199.92 E:213443.61 STA. 10+87.84 8"x4" TEE w/ TB N:103139.72 E:213441.81 60.23 LF 8" PVC N01°42'19"E 87.84 LF 8" PVC N01°43'41"E 68.91 LF 8" PVCS88°12'34"E38.48 LF 8" PVCS88°12'34"E18.27 LF 8" PVC S01°33'11"E 23.75 LF 8" PVC S01°33'11"E 5.00 LF 8" PVC S01°33'11"E 137.28 LF 8" PVC S01°33'11"E 26.07 LF 8" PVC S01°33'11"E 98.75 LF 8" PVC S01°33'11"E 97.09 LF 8" PVC N01°32'33"W 16.86 LF 8" PVC N01°32'33"W 141.10 LF 8" PVC N01°32'33"W 12.75 LF 8" PVC N01°32'33"W 47.99 LF 8" PVC N01°32'33"W STA. 20+02.62 45.00° BEND w/ TB N:102754.06 E:213560.61STA. 16+85.98 45.00° BEND w/ TB N:103068.55 E:213547.10 STA. 15+36.59 45.00° BEND w/ TB N:103068.15 E:213399.78 7.51 LF 8" PVC N01°36'57"W STA. 12+20.79 8"x4" TEE w/ TB N:102752.46 E:213408.28 STA. 13+17.88 8"x4" TEE w/ TB N:102849.52 E:213405.67 STA. 13+34.74 8"x4" TEE w/ TB N:102866.37 E:213405.21 STA. 14+88.60 8"x4" TEE w/ TB N:103020.17 E:213401.07 STA. 14+75.85 8"x4" TEE w/ TB N:103007.43 E:213401.42 4870 4875 4880 4885 4890 4895 4900 4905 4910 4915 4870 4875 4880 4885 4890 4895 4900 4905 4910 4915 9+5010+0011+0012+0013+0014+0015+0016+00 STA.=10+34.18 INV.= 4889.66 EX 18" RCP STORM STA.=10+43.31 EX CABLESTA.=10+48.20 EX CABLE STA.=10+53.10 EX ELECTRIC STA.=11+01.99 INV.= 4891.83 PR 15" RCP STORM STA.=11+69.78 PR GAS STA.=12+03.28 INV.= 4891.92 PR 8" PVC SANITARY EXISTING GROUND 4897.114897.174897.414897.734898.054898.354898.654898.974899.294899.604899.914900.224900.534900.844901.164901.474901.784902.094902.474902.774902.884902.88STA.=13+54.93 PR ELECTRIC STA.=13+56.93 PR ELECTRIC PROPOSED GROUND EXISTING GROUND PROPOSED GROUNDSTA. 15+43.4645° BEND w/ TBT.O.P.=4897.25STA. 15+78.608"X8" TEE w/ TB & 3-8" GVsT.O.P.=4897.43STA. 11+60.75FH ASSEMBLY8"X6" SWIVEL TEE w/ TB & 6" GV (E)T.O.P.=4889.94STA. 12+13.288"X8" TEE w/ TB & 3-8" GVsT.O.P.=4889.94STA. 12+20.798"X4" SWIVEL TEE W/ 4" GV (W)T.O.P.=4890.36STA. 13+17.888"X4" TEE W/ 4" GV (E)T.O.P.=4894.22STA. 13+34.748"X4" TEE W/ 4" GV (W)T.O.P.=4894.46STA. 14+75.858"X4" TEE W/ 4" GV (W)T.O.P.=4896.46STA. 14+88.608"X4" TEE W/ 4" GV (E)T.O.P.=4896.65STA. 15+36.5945° BEND W/ TBT.O.P.=4897.19184.5' DEF.STA. 14+90.70T.O.P.=4896.68(@ 0.1°) 71.0' DEF.STA. 12+42.05T.O.P.=4893.65STA. 13+13.04T.O.P.=4894.15(@ 0.2°)STA. 10+00.0CONNECT TO EX WATER MAINTAPPING SLEEVE W/ 8" GV(CONTRACTOR TO POTHOLE PRIOR TOCONSTRUCTION TO VERIFY DEPTH)T.O.P.=4891.85STA. 10+51.245.00° BENDT.O.P.=4889.94STA. 12+18.711.25° BENDT.O.P.=4889.94STA. 12+37.311.25° BENDT.O.P.=4893.65STA. 10+49.245.00° BENDT.O.P.=4887.96STA. 10+15.345.00° BENDT.O.P.=4891.85STA. 10+19.245.00° BENDT.O.P.=4887.96STA.=10+21.17 INV.= 4877.99 EX 24" PVC SANITARY 18" MIN.18" MIN. 18" MIN. 8" PVC 8" PVC 8" PVC WT1 PLAN & PROFILEWATER LINE15 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NORTH ( IN FEET ) 1 inch = ft. Feet03030 30 60 90 WT1/WT2/WT3PROFILE SCALE: LINE MATCH STA 16+00 WATER LINE STAMATCH LINESEE SHEET16+00WT2SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 35 KEYMAP KECHTER RD (C.R. 36)QUASARWAYNOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL WATER CONSTRUCTION SHALL BE PER FORT COLLINS - LOVELAND WATER DISTRICT, LATEST EDITION, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR AS REQUIRED FOR ABNORMAL DEFLECTIONS. 3.ALL SEWER CONSTRUCTION SHALL BE PER SOUTH FORT COLLINS SANITATION DISTRICT SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST EDITION. 4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5.ALL WATERLINES SHALL HAVE A 5-FT MINIMUM AND 6-FT MAXIMUM WATER LINE COVER FROM FINISHED GRADE TO TOP OF PIPE. 6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS. 10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 11.ALL INDIVIDUAL WATER SERVICES SHALL BE 3/4". ALL DUAL WATER SERVICES SHALL BE 1" BETWEEN THE TAP ON THE MAIN AND THE BRANCH YOLK IN THE METER PIT. EXISTING LOT LINE EASEMENT LINE SPROPOSED SEWER SERVICE WPROPOSED WATER SERVICE EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT W SS PROPOSED LOT LINE PROPOSED ROW EXISTING ROW EXISTING CABLE CTV PROPOSED WATER METER PIT TTT TG G GGG G G G G G G G G G G G G GGGGGGGGGGGGGGGGGGGGGGGGGGEEEEEEEET ETEEEEEEEEEEETTTEEEEEEEEEEEEEEEEEEEEEEEEEE E E E E E EEEEEE E E E T EEEEEEEEEEG G G GGG GGGGGGGC/OC/OGASSCONTROLIRRCONTROLIRRWETTTCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVT T TTEEEE E EEEEGGGGGGG G WWWWSTSTSTSTSTSTSTSTSTSTSTSSSSSSSSSSSSSSSSSSSSSSSSCTVCTVCTVCTVCTVXXXXXXXXELECWWWWWWWWWWLOGGERS LANECACTUS CURVEWHEELHOUSE WAY QUASAR WAY CACTUS CURVE KECHTER ROAD (C.R. 36)(70' PUBLIC ROW)PARCEL W WILLOW BROOK PARCEL R WILLOW BROOK STORM DRAIN LINE A SEE SHEET ST1 STORM DRAIN LINE B SEE SHEET ST2 STORM DRAIN LINE C SEE SHEET ST3 STORM DRAIN LINE D SEE SHEET ST3 STORM DRAIN LINE E SEE SHEET ST3 STORM DRAIN LINE F SEE SHEET ST3 STORM DRAIN LINE G SEE SHEET ST2 SANTARY LINE A-2 SEE SHEET SS2 7 ACCESS EASEMENT 9 UTILITY EASEMENT 9 UTILITY EASEMENT 9 UTILITY EASEMENT 9 UTILITY EASEMENT 14 DRAINAGE EASEMENT 15 UTILITY EASEMENT REC. NO. 20190009470 RAIN GARDEN B POND 1 RAIN GARDEN A PR FIRE HYDRANT #1 PR FIRE HYDRANT #2 APPROXIMATE LIMITS OF ASPAHLT PATCH CONNECT TO EX WATER MAIN TAPPING SLEEVE W/ 8" GV (N) (CONTRACTOR TO POTHOLE TO VERIFY DEPTH PRIOR TO CONSTRUCTION) N:102531.75 E:213414.22 RELOCATED EX FH CONNECT TO EX WATER MAIN TAPPING SLEEVE W/ 8" GV (N) (CONTRACTOR TO POTHOLE TO VERIFY DEPTH PRIOR TO CONSTRUCTION) N:103203.92 E:213443.72 STA. 15+43.46 45.00° BEND w/ TB N:103073.00 E:213404.65 STA. 20+09.69 45.00° BEND w/ TB N:102748.92 E:213555.75 STA. 15+78.60 8"x8" TEE w/ TB & 3-8" GVs N:103071.90 E:213439.76 STA. 11+60.75 8"x6" SWIVEL TEE w/ TB & 6" GV (E) N:102692.44 E:213409.91 STA. 12+13.28 8"x8" TEE w/ TB & 3-8" GVs N:102744.96 E:213408.49 6.87 LF 8" PVC N45°05'32"E 160.75 LF 8" PVC N01°32'18"W52.54 LF 8" PVC N01°32'39"W35.13 LF 8" PVCS88°12'34"E7.07 LF 8" PVC S43°27'08"W 147.31 LF 8" PVCS88°27'27"WSTA. 17+11.76 8"x6" SWIVEL TEE w/ TB & 6" GV (W) N:103044.81 E:213552.73 STA. 16+93.49 45.00° BEND w/ TB N:103063.07 E:213552.24 7.51 LF 8" PVC S43°12'34"E SANITARY LINE A-1 SEE SHEET SS1 IRRIGATION SERVICE STA. 17+35.52 8"x4" TEE w/ TB N:103021.07 E:213553.38 STA. 17+40.52 8"x4" TEE w/ TB N:103016.07 E:213553.51 STA. 18+77.80 8"x4" TEE w/ TB N:102878.84 E:213557.23 STA. 19+03.87 8"x4" TEE w/ TB N:102852.77 E:213557.94 STA. 16+47.51 8"x6" TEE w/ TB N:103069.75 E:213508.64 STA. 11+48.07 8"x6" SWIVEL TEE w/ TB & 6" GV (W) N:103199.92 E:213443.61 STA. 10+87.84 8"x4" TEE w/ TB N:103139.72 E:213441.81 60.23 LF 8" PVC N01°42'19"E 87.84 LF 8" PVC N01°43'41"E 68.91 LF 8" PVCS88°12'34"E38.48 LF 8" PVCS88°12'34"E18.27 LF 8" PVC S01°33'11"E 23.75 LF 8" PVC S01°33'11"E 5.00 LF 8" PVC S01°33'11"E 137.28 LF 8" PVC S01°33'11"E 26.07 LF 8" PVC S01°33'11"E 98.75 LF 8" PVC S01°33'11"E 97.09 LF 8" PVC N01°32'33"W 16.86 LF 8" PVC N01°32'33"W 141.10 LF 8" PVC N01°32'33"W 12.75 LF 8" PVC N01°32'33"W 47.99 LF 8" PVC N01°32'33"W STA. 20+02.62 45.00° BEND w/ TB N:102754.06 E:213560.61STA. 16+85.98 45.00° BEND w/ TB N:103068.55 E:213547.10 STA. 15+36.59 45.00° BEND w/ TB N:103068.15 E:213399.78 7.51 LF 8" PVC N01°36'57"W STA. 12+20.79 8"x4" TEE w/ TB N:102752.46 E:213408.28 STA. 13+17.88 8"x4" TEE w/ TB N:102849.52 E:213405.67 STA. 13+34.74 8"x4" TEE w/ TB N:102866.37 E:213405.21 STA. 14+88.60 8"x4" TEE w/ TB N:103020.17 E:213401.07 STA. 14+75.85 8"x4" TEE w/ TB N:103007.43 E:213401.42 4870 4875 4880 4885 4890 4895 4900 4905 4910 4915 4870 4875 4880 4885 4890 4895 4900 4905 4910 4915 16+0017+0018+0019+0020+0021+0022+00 PROPOSED GROUND EXISTING GROUND 4902.884902.754902.554902.344902.144901.844901.624901.414901.194900.984900.764900.554900.334900.124899.904899.694899.584899.374899.194899.004898.784898.564898.33STA.=18+64.01 PR ELECTRIC STA.=18+66.01 PR ELECTRIC STA.=20+80.82 INV.= 4895.25 PR 15" RCP STORM EXISTING GROUND PROPOSED GROUNDSTA.=20+25.92 EX TELEPHONE (TO BE REMOVED) 8" PVC 8" PVC 8" PVC8" PVCSTA. 20+09.6945° BEND W/ TBT.O.P.=4894.08STA. 15+78.608"X8" TEE w/ TB & 3-8" GVsT.O.P.=4897.43STA. 16+93.4945° BEND W/ TBT.O.P.=4896.97STA. 17+11.76FH ASSEMBLY8"X6" SWIVEL TEE W/ 6" GV (W)T.O.P.=4896.81STA. 16+47.518"X4" TEE W/ 4" GV (N)T.O.P.=4897.35STA. 16+85.9845° BEND W/ TBT.O.P.=4897.04STA. 17+35.528"X4" TEE W/ 4" GV (W)T.O.P.=4896.59STA. 17+40.528"X4" TEE W/ 4" GV (E)T.O.P.=4896.54STA. 18+77.808"X4" TEE W/ 4" GV (E)T.O.P.=4895.29STA. 19+03.878"X4" TEE W/ 4" GV (W)T.O.P.=4895.05STA. 20+02.6245° BEND W/ TBT.O.P.=4894.14184.5' DEF.STA. 16+75.19T.O.P.=4897.14(@ 0.1°) 76.7' DEF.STA. 20+42.48T.O.P.=4893.78STA. 21+19.16T.O.P.=4893.37(@ 0.1°)STA. 21+57.08"X8" TEE w/ TB & 3-8" GVsT.O.P.=4890.35STA. 21+34.511.17° BENDT.O.P.=4893.35STA. 21+49.511.25° BENDT.O.P.=4890.3518" MIN. WT2 PLAN & PROFILEWATER LINE16 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NORTH ( IN FEET ) 1 inch = ft. Feet03030 30 60 90 PROFILE SCALE: LINE MATCH STA 16+00 WATER LINE STAMATCH LINESEE SHEET16+00WT1SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 35 KEYMAP KECHTER RD (C.R. 36)QUASARWAYNOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL WATER CONSTRUCTION SHALL BE PER FORT COLLINS - LOVELAND WATER DISTRICT, LATEST EDITION, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR AS REQUIRED FOR ABNORMAL DEFLECTIONS. 3.ALL SEWER CONSTRUCTION SHALL BE PER SOUTH FORT COLLINS SANITATION DISTRICT SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST EDITION. 4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5.ALL WATERLINES SHALL HAVE A 5-FT MINIMUM AND 6-FT MAXIMUM WATER LINE COVER FROM FINISHED GRADE TO TOP OF PIPE. 6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS. 10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 11.ALL INDIVIDUAL WATER SERVICES SHALL BE 3/4". ALL DUAL WATER SERVICES SHALL BE 1" BETWEEN THE TAP ON THE MAIN AND THE BRANCH YOLK IN THE METER PIT. EXISTING LOT LINE EASEMENT LINE SPROPOSED SEWER SERVICE WPROPOSED WATER SERVICE EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT W SS PROPOSED LOT LINE PROPOSED ROW EXISTING ROW EXISTING CABLE CTV PROPOSED WATER METER PIT WT1/WT2/WT3 TTT TG G GGG G G G G G G G G G G G G GGGGGGGGGGGGGGGGGGGGGGGGGGEEEEEEEET ETEEEEEEEEEEETTTEEEEEEEEEEEEEEEEEEEEEEEEEE E E E E E EEEEEE E E E T EEEEEEEEEEG G G GGG GGGGGGGC/OC/OGASSCONTROLIRRCONTROLIRRWETTTCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVT T TTEEEE E EEEEGGGGGGG G WWWWSTSTSTSTSTSTSTSTSTSTSTSSSSSSSSSSSSSSSSSSSSSSSSCTVCTVCTVCTVCTVXXXXXXXXELECWWWWWWWWWWLOGGERS LANECACTUS CURVEWHEELHOUSE WAY QUASAR WAY CACTUS CURVE KECHTER ROAD (C.R. 36)(70' PUBLIC ROW)PARCEL W WILLOW BROOK PARCEL R WILLOW BROOK STORM DRAIN LINE A SEE SHEET ST1 STORM DRAIN LINE B SEE SHEET ST2 STORM DRAIN LINE C SEE SHEET ST3 STORM DRAIN LINE D SEE SHEET ST3 STORM DRAIN LINE E SEE SHEET ST3 STORM DRAIN LINE F SEE SHEET ST3 STORM DRAIN LINE G SEE SHEET ST2 SANTARY LINE A-2 SEE SHEET SS2 7 ACCESS EASEMENT 9 UTILITY EASEMENT 9 UTILITY EASEMENT 9 UTILITY EASEMENT 9 UTILITY EASEMENT 14 DRAINAGE EASEMENT 15 UTILITY EASEMENT REC. NO. 20190009470 RAIN GARDEN B POND 1 RAIN GARDEN A PR FIRE HYDRANT #1 PR FIRE HYDRANT #2 APPROXIMATE LIMITS OF ASPAHLT PATCH CONNECT TO EX WATER MAIN TAPPING SLEEVE W/ 8" GV (N) (CONTRACTOR TO POTHOLE TO VERIFY DEPTH PRIOR TO CONSTRUCTION) N:102531.75 E:213414.22 RELOCATED EX FH CONNECT TO EX WATER MAIN TAPPING SLEEVE W/ 8" GV (N) (CONTRACTOR TO POTHOLE TO VERIFY DEPTH PRIOR TO CONSTRUCTION) N:103203.92 E:213443.72 STA. 15+43.46 45.00° BEND w/ TB N:103073.00 E:213404.65 STA. 20+09.69 45.00° BEND w/ TB N:102748.92 E:213555.75 STA. 15+78.60 8"x8" TEE w/ TB & 3-8" GVs N:103071.90 E:213439.76 STA. 11+60.75 8"x6" SWIVEL TEE w/ TB & 6" GV (E) N:102692.44 E:213409.91 STA. 12+13.28 8"x8" TEE w/ TB & 3-8" GVs N:102744.96 E:213408.49 6.87 LF 8" PVC N45°05'32"E 160.75 LF 8" PVC N01°32'18"W52.54 LF 8" PVC N01°32'39"W35.13 LF 8" PVCS88°12'34"E7.07 LF 8" PVC S43°27'08"W 147.31 LF 8" PVCS88°27'27"WSTA. 17+11.76 8"x6" SWIVEL TEE w/ TB & 6" GV (W) N:103044.81 E:213552.73 STA. 16+93.49 45.00° BEND w/ TB N:103063.07 E:213552.24 7.51 LF 8" PVC S43°12'34"E SANITARY LINE A-1 SEE SHEET SS1 IRRIGATION SERVICE STA. 17+35.52 8"x4" TEE w/ TB N:103021.07 E:213553.38 STA. 17+40.52 8"x4" TEE w/ TB N:103016.07 E:213553.51 STA. 18+77.80 8"x4" TEE w/ TB N:102878.84 E:213557.23 STA. 19+03.87 8"x4" TEE w/ TB N:102852.77 E:213557.94 STA. 16+47.51 8"x6" TEE w/ TB N:103069.75 E:213508.64 STA. 11+48.07 8"x6" SWIVEL TEE w/ TB & 6" GV (W) N:103199.92 E:213443.61 STA. 10+87.84 8"x4" TEE w/ TB N:103139.72 E:213441.81 60.23 LF 8" PVC N01°42'19"E 87.84 LF 8" PVC N01°43'41"E 68.91 LF 8" PVCS88°12'34"E38.48 LF 8" PVCS88°12'34"E18.27 LF 8" PVC S01°33'11"E 23.75 LF 8" PVC S01°33'11"E 5.00 LF 8" PVC S01°33'11"E 137.28 LF 8" PVC S01°33'11"E 26.07 LF 8" PVC S01°33'11"E 98.75 LF 8" PVC S01°33'11"E 97.09 LF 8" PVC N01°32'33"W 16.86 LF 8" PVC N01°32'33"W 141.10 LF 8" PVC N01°32'33"W 12.75 LF 8" PVC N01°32'33"W 47.99 LF 8" PVC N01°32'33"W STA. 20+02.62 45.00° BEND w/ TB N:102754.06 E:213560.61STA. 16+85.98 45.00° BEND w/ TB N:103068.55 E:213547.10 STA. 15+36.59 45.00° BEND w/ TB N:103068.15 E:213399.78 7.51 LF 8" PVC N01°36'57"W STA. 12+20.79 8"x4" TEE w/ TB N:102752.46 E:213408.28 STA. 13+17.88 8"x4" TEE w/ TB N:102849.52 E:213405.67 STA. 13+34.74 8"x4" TEE w/ TB N:102866.37 E:213405.21 STA. 14+88.60 8"x4" TEE w/ TB N:103020.17 E:213401.07 STA. 14+75.85 8"x4" TEE w/ TB N:103007.43 E:213401.42 4885 4890 4895 4900 4905 4910 4915 4885 4890 4895 4900 4905 4910 4915 9+5010+0011+0012+00 4902.904902.994902.664902.994903.494903.814903.82PROPOSED GROUND EXISTING GROUND PROPOSED GROUND EXISTING GROUND STA.=11+00.35 PR ELECTRIC STA.=11+29.04 INV.= 4901.25 PR 15" RCP STORM 8" PVC STA. 10+20.08"X8" TEE w/ TB & 3-8" GVsT.O.P.=4897.43STA. 11+52.1CONNECT TO EX WATER MAINTAPPING SLEEVE W/ 8" GV(CONTRACTOR TO POTHOLE PRIOR TOCONSTRUCTION TO VERIFY DEPTH)T.O.P.=4897.43STA. 10+87.848"X4" TEE W/ 4" GV (W)T.O.P.=4897.43STA. 11+48.07FH ASSEMBLY8"X6" SWIVEL TEE W/ 6" GV (W)T.O.P.=4897.43WT3 PLAN & PROFILEWATER LINE17 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NORTH ( IN FEET ) 1 inch = ft. Feet03030 30 60 90 PROFILE SCALE: WATER LINE SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 35 KEYMAP KECHTER RD (C.R. 36)QUASARWAYNOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL WATER CONSTRUCTION SHALL BE PER FORT COLLINS - LOVELAND WATER DISTRICT, LATEST EDITION, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR AS REQUIRED FOR ABNORMAL DEFLECTIONS. 3.ALL SEWER CONSTRUCTION SHALL BE PER SOUTH FORT COLLINS SANITATION DISTRICT SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST EDITION. 4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5.ALL WATERLINES SHALL HAVE A 5-FT MINIMUM AND 6-FT MAXIMUM WATER LINE COVER FROM FINISHED GRADE TO TOP OF PIPE. 6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS. 10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 11.ALL INDIVIDUAL WATER SERVICES SHALL BE 3/4". ALL DUAL WATER SERVICES SHALL BE 1" BETWEEN THE TAP ON THE MAIN AND THE BRANCH YOLK IN THE METER PIT. EXISTING LOT LINE EASEMENT LINE SPROPOSED SEWER SERVICE WPROPOSED WATER SERVICE EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT W SS PROPOSED LOT LINE PROPOSED ROW EXISTING ROW EXISTING CABLE CTV PROPOSED WATER METER PIT WT1/WT2/WT3 VAULT ELEC VAULT ELEC GAS S VAULT ELEC FES CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR LID S VAULT ELEC W FE SD S S SS HY DCONTROL IRR CONTROL IRR CONTROL IRR D E VAULT ELEC T VAULT ELECCXGCTVTE EW W W W CTV CTV CTV CTV CTV CTV CTV CTV CTVTT E E E E XXXXXXXXXXE EX EG G G GGGGWW STST ST ST ST ST ST ST ST ST STSSSS SS SS SS SS SS SS SS SS SS SS SS SSSS SS SSSSSS CTV CTV CTV CTV XX X X X X X X XXXXXXELEC WWWWWWWWWWWWWWWPARCEL X WILLOW BROOK PARCEL W WILLOW BROOK PARCEL R WILLOW BROOK POUDRE R-1 SCHOOL DISTRICT PARCEL NO. 8604000904 KECHTER ROAD (C.R. 36) (70' PUBLIC ROW)CACTUS CURVE(53' PUBLIC ROW)WHEELHOUSE WAY(53' PUBLIC ROW)QUASAR WAY(53' PUBLIC ROW)LOGGERS LANE (53' PUBLIC ROW) ECLIPSE LANE (53' PUBLIC ROW) RAIN GARDEN B POND 1 STORM DRAIN LINE A SEE SHEET ST1 STORM DRAIN LINE B SEE SHEET ST2 STORM DRAIN LINE C SEE SHEET ST3 STORM DRAIN LINE D SEE SHEET ST3 STORM DRAIN LINE E SEE SHEET ST3 STORM DRAIN LINE F SEE SHEET ST3 CACTUS CURVE (53' PUBLIC ROW) STORM DRAIN PROPOSED POND 1 OUTFALL PROPOSED STORM DRAIN OG1 OVERALL GRADING PLAN18 NORTH ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 G1 G2 KEYMAP KECHTER RD (C.R. 36)QUASARWAYSheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 35 PROPOSED CONTOUR EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED SPOT ELEVATION PROPOSED SLOPES 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3.ALL PROJECT DATA IS ON VERTICAL DATUM NAVD88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. NOTES: PROPOSED STORM INLET EXISTING SPOT ELEVATION EXISTING LOT LINE PROPOSED CONCRETE CROSS PAN (TYP.) EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPOSED RIGHT OF WAY LOT TYPE LEGEND: PROPOSED GRADE BREAK CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R VAULT ELEC VAULT ELEC GAS S VAULT ELEC FES CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR LID HY DCONTROL IRR CONTROL IRR CONTROL IRRXX W W WXXXXX XXXXXXXXEEG G G G G G G G GGGGGGGW W W WWWSSSSSS SS XXX X X X X X X X X X X X X X XXXXXXXXXXXPARCEL X WILLOW BROOK PARCEL W WILLOW BROOK PARCEL R WILLOW BROOK POUDRE R-1 SCHOOL DISTRICT PARCEL NO. 8604000904 LOGGERS LANE ECLIPSE LANEQUASAR WAYWHEELHOUSE WAYCACTUS CURVE0.531.301.661.921.992.082.372.472.563.002.71 2.84 2.90 3.03 2. 9 9 2.882.73 2.62 2.54 2.43 1.531. 3 6 0.821. 0 01.201.371.631.792.052.222.452.201. 8 3 1.591.220.980. 6 5 0. 5 9 2. 5 0 1.002.752.502. 5 0 2. 5 0 2.502. 5 0 1.002.752.752.752.752.752.752.500.500.350.952.400.75 0.75 1.25 1.50 1.50 2.25 2.25 2.25 (2 . 1 0 )0.500.0699.8699.5999.3999.2598.5398.75(0.94)(0.74)(0.99)(1.12)(1.36)(1 . 9 6 )(2.07)(2.10)(2 . 1 0 )1.35(2.17)(2.60)3.003.50 3.50 4.501. 7 6 2. 2 2(2.97)(2.51)(2.40)(3.62)4.25 2. 2 5 2.252. 2 5 2.253.122. 2 5 2.252.262. 2 5 1. 5 01.331.822.352. 1 5(2.39)(2.32)(2.53)(2.17)(1.91)(2.82)(1.95) (1.99) (2.21) (1.83) (1.85) (1.87) (1.90) (2.11) 2. 2 5 1.751.751.802. 0 02.002.001. 9 8 2. 2 5 2.250.991.030.700. 7 51.08(3.42)2.00(2.26)1.931.951.961. 7 8 2. 0 2 2. 2 9 2. 2 51.00(1.98)2. 0 0 (1.89)(1.80)1.052.402.502.502. 7 5 2.40 2.40 2.40 2.40 3.503.50 FES INV=4900.57 FES INV=4900.65 FES INV=4901.27 FES INV=4901.22 FES INV=4901.06 FES INV=4901.07 IN-LINE DRAIN RIM=4901.00 IN-LINE DRAIN RIM=4901.00 IN-LINE DRAIN RIM=4901.00 IN-LINE DRAIN RIM=4901.50 IN-LINE DRAIN RIM=4901.00 IN-LINE DRAIN RIM=4902.00 IN-LINE DRAIN RIM=4902.00 IN-LINE DRAIN RIM=4900.50 FFE=5.00 FFE=5.00 FFE=5.00 FFE=5.00 FFE=4.75 FFE=4.75 FFE=4.75 FFE=4.75 FFE=4.75 FFE=4.75 FFE=2.75 FFE=3.75 FFE=3.75 FFE=3.75 FFE=3.75 FFE=2.25 FFE=4.25 FFE=4.25 FFE=4.25 FFE=4.25 FFE=4.25 FFE=4.25 FFE=0.85 FFE=4.00 FFE=4.00 FFE=4.00 FFE=4.00 FFE=4.00 FFE=4.00 FFE=2.75 FFE=3.50 FFE=3.50 FFE=3.50 GFFE=1.75 GFFE=2.25 GFFE=2.75 GFFE=3.50 GFFE=3.50 GFFE=3.25 GFFE=3.25 GFFE=3.25 GFFE=2.50 GFFE=2.00 GFFE=2.00 GFFE=1.25 GFFE=1.60 GFFE=2.00 GFFE=2.50GFFE=2.75 GFFE=2.25 GFFE=1.85 FFE=3.50 FFE=2.50 PROPOSED SWALE PROPOSED SWALE PROPOSED SWALE PROPOSED STORM DRAIN PROPOSED CULVERT COORDINATE DESIGN & CONSTRUCTION WITH THE IRRIGATION DITCH COMPANY PROPOSED CULVERT COORDINATE DESIGN & CONSTRUCTION WITH THE IRRIGATION DITCH COMPANY KEYMAP KECHTER RD (C.R. 36)QUASARWAYG1 GRADING PLAN19 NORTH ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 MATCH LINE - SEE SHEET G2 G1 G2 SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 35 PROPOSED CONTOUR EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED SPOT ELEVATION PROPOSED SLOPES 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3.ALL PROJECT DATA IS ON VERTICAL DATUM NAVD88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. NOTES: PROPOSED STORM INLET EXISTING SPOT ELEVATION EXISTING LOT LINE PROPOSED CONCRETE CROSS PAN (TYP.) EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPOSED RIGHT OF WAY LOT TYPE LEGEND: PROPOSED GRADE BREAK CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R S VAULT ELEC W FES D S S D E VAULT ELEC T CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTVTTTTT E E E E E E E EXXXXXXXXXXXX XXXE E E E E STSTST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST STSTSTST SSSSSS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SSSSSSC T V CTV CTV CTV CTV CTV CTV CTV CTV XXXXXELEC WWWWWWWWWWWWWWWWWWWWWWWWWW4:1PARCEL X WILLOW BROOK CITY OF FORT COLLINS PARCEL NO. 8609128901 POUDRE R-1 SCHOOL DISTRICT PARCEL NO. 8604000904 CACTUS CURVE WHEELHOUSE WAYCACTUS CURVEKECHTER ROAD (C.R. 36) (70' PUBLIC ROW)97.9098.1598.5198.7698.9599.4099.920.530.821. 0 0 0. 6 9 0. 5 8 0. 2 9 0. 0 8 100.00 97.40 98.74 99.83 97.40 99.0099.47(2.42)91.869 3 . 8 5 0.180.350.600.771.200.980.650.330.200.5999.472. 5 0 1. 0 0 1.002.750.500.350.950. 5 0 0.350.350. 5 0 9 9 . 7 1 99.2396.65 96.65 96.65 96.65 96.65 98.15 98.75 0.75 99.75 99.75 0.75 0.75 1.25 1.5099.3999.2598.5398.2297.7897.4798.7597.2597.0096.3996.1195.7395.25(9 6 . 4 3 )(95.93)(96.56)(96.87)(9 8 . 0 8 )(98.60)(0.94)(98.98)(99.52)(0.28)(0 . 7 4 )(0.99)(1 . 1 2 ) (1.90) (2.11) (2.26) (2.30) (1.87) (2.02) (2.25) (2.24) (1.97) 93.8597.0092.6091.8597.402. 0 02.062. 2 5 2. 2 5 2. 2 5 2.252.251.600.9897.401. 9 8 2. 2 5 2. 2 5 97.009 7 . 0 0 93.851.0093.85 99.49 9 2 . 3 9 93.8593.85 0.991.030.700. 7 5 0.0691.8098.3998.1598.360. 0 7 97.0099.0492.5092.9093.8597.0095.88 5:193.85 97.0092.2993.8599.0799.3399.670.281.0595.45(9 5 . 8 7 )(97.69)0. 1 8 0.102.40 0.43 0.500.3596.40 3. 0% 3.0%0.5%0.5%0.5%0.5% 0.5% 91.25 9 1 . 4 9 9 1 . 3 4 9 1 . 3 0 INLET FL=4898.86 INLET FL=4898.50 OUTLET STRUCTURE RIM=4897.30 OUTLET STRUCTURE RIM=4895.10 STORM MH RIM=4897.81 FES INV=4891.40 FES INV=4891.44 FES INV=4891.64 FES INV=4891.70 FES INV=4896.40 IN-LINE DRAIN RIM=4901.00 IN-LINE DRAIN RIM=4901.00 IN-LINE DRAIN RIM=4900.43 IN-LINE DRAIN RIM=4900.21 INLET FL=4896.89 IN-LINE DRAIN RIM=4900.50 FFE=3.75 FFE=2.25 FFE=2.25 FFE=2.25 FFE=2.25 FFE=99.65 FFE=0.65 FFE=0.65 FFE=0.65 FFE=0.65 FFE=4.25 FFE=0.85 FFE=2.35 FFE=2.35 FFE=2.35 FFE=2.50 FFE=2.50 FFE=2.50 FFE=1.00 FFE=4.00 FFE=4.00 FFE=0.25 FFE=2.75 FFE=2.75 FFE=2.75 FFE=2.75 FFE=3.50 GFFE=98.65 GFFE=99.15 GFFE=99.65 GFFE=0.25 GFFE=0.75 GFFE=1.75 GFFE=1.25 GFFE=0.75 GFFE=0.25GFFE=0.50 GFFE=1.00 GFFE=1.00 GFFE=1.60GFFE=1.85 GFFE=0.85 GFFE=0.85 POND 1 BOT EL=4891.85 4-FT WIDE STEP EL=4893.85 TOP EL=VARIES/STEPPED (MIN.=4896.90) OUTLET EL=4896.70 REQUIRED VOL=35,040 CF PROVIDED VOL=36,028 CF RAIN GARDEN A BOT=4894.0 TOP=4895.0 (4:1 SIDES) RAIN GARDEN B BOT=4896.4 TOP=4897.4 (4:1 SIDES) GFFE=99.95 UPPER DETENTION WALL TO BE RAISED TO MATCH EX GRADE AT DRIPLINE UPPER DETENTION WALL TO BE RAISED TO REDUCE SLOPE FROM ROAD TAPER TOP WALL TAPER TOP WALL EX DRIPLINE CANOPY (AREA UNDEERNEATH TO REMAIN UNDISTURBED) SIDEWALK CHASE STEPPED WALL STEPPED WALL STEPPED WALL MAINTENANCE ACCESS EX DRIPLINE CANOPY (AREA UNDEERNEATH TO REMAIN UNDISTURBED) SIDEWALK CHASE OUTLET STRUCTURE RIM=4896.70 FLOW CONTROL GRATE INV. IN=4891.25 EX DRIPLINE STEPPED WALL FG@T.O.W.=97.00 4-FT WIDE BENCH=94.00 FG@B.O.W.=92.00 PROPOSED POND 1 OUTFALL PR SWALE PROPOSED SWALE PROPOSED STORM DRAIN PROPOSED STORM DRAIN KEYMAP KECHTER RD (C.R. 36)QUASARWAYG2 GRADING PLAN20 NORTH ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 MATCH LINE - SEE SHEET G1 G1 G2 SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 35 PROPOSED CONTOUR EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED SPOT ELEVATION PROPOSED SLOPES 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3.ALL PROJECT DATA IS ON VERTICAL DATUM NAVD88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. NOTES: PROPOSED STORM INLET EXISTING SPOT ELEVATION EXISTING LOT LINE PROPOSED CONCRETE CROSS PAN (TYP.) EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPOSED RIGHT OF WAY LOT TYPE LEGEND: PROPOSED GRADE BREAK CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R T TGGGGGGGGGGGGGGGGGGG G EE TTE E E E E E EE TT TEEEEE E E E E E E EEEEEEEEEEEEEGGGGGG G GLOGGERS LANECACTUSCURVEWHEELHOUSE WAY QUASAR WAY VAULTELECGASSFESCONTROLIRRCONTROLIRRSVAULTELECWSXCTVCTVCTVCTVCTVEEXEGG GGWWSTSTSTST STSTSS SSSSSSSSSSSSSSSSCTVCTVCTVCTVXXXXELECWWWWWWPARCEL R WILLOW BROOK STORM DRAIN LINE B SEE SHEET ST2 STORM DRAIN LINE D SEE SHEET ST3 STORM DRAIN LINE E SEE SHEET ST3 STORM DRAIN LINE F SEE SHEET ST3 STORM DRAIN LINE G SEE SHEET ST2 SANTARY LINE A-2 SEE SHEET SS2 7 ACCESS EASEMENT 9 UTILITY EASEMENT 9 UTILITY EASEMENT 9 UTILITY EASEMENT 14 DRAINAGE EASEMENT 6 DRAINAGE & UTILITY EASEMENT KECHTER ROAD (C.R. 36)(70' PUBLIC ROW)4890 4895 4900 4905 4910 4890 4895 4900 4905 4910 0+00 1+00 2+00 3+00 4+00 5+00 6+00 52.4' VC LP ELEV = 4897.31 LP STA = 0+37.80 PVI STA = 0+49.00 PVI ELEV = 4897.22 BCVS: 0+22.80BVCE: 4897.35ECVS: 0+75.21EVCE: 4897.55A.D. = 1.75 K = 30.00 105.3' VC HP ELEV = 4903.10 HP STA = 5+51.46 PVI STA = 5+41.74 PVI ELEV = 4903.36BVCS: 4+89.10BVCE: 4902.71EVCS: 5+94.38EVCE: 4902.91A.D. = 2.11 K = 50.00 1.25% -0.50%-2.00% -2.34%2.34% -0.86% EXISTING GROUND PROPOSED GRADE 8' WIDE VALLEY PAN 4890 4895 4900 4905 4910 4890 4895 4900 4905 4910 0+00 1+00 2+00 3+00 4+00 5+00 6+00 4890 4895 4900 4905 4910 4890 4895 4900 4905 4910 0+00 1+00 2+00 3+00 4+00 5+00 6+004896.954896.954897.154897.464897.784898.094898.404898.714899.024899.334899.654899.964900.274900.584900.894901.204901.524901.834902.164902.594902.704902.634902.484902.264897.454897.344897.344897.544897.864898.174898.484898.794899.104899.414899.734900.044900.354900.664900.974901.294901.604901.914902.224902.534902.834903.034903.104903.044902.864896.954896.954897.154897.464897.784898.094898.404898.714899.024899.334899.654899.964900.274900.584900.894901.204901.524901.714901.904902.094902.284902.474902.624902.65-0.50%0.50%0.50% 1.25% 1.72%0.48%-0.56%-0.86% 47.0' VC HP ELEV = 4902.70 HP STA = 5+25.34 PVI STA = 5+27.20 PVI ELEV = 4902.76 BVCS: 5+03.68BVCE: 4902.65EVCS: 5+50.72EVCE: 4902.63A.D. = 1.05 K = 45.00 22.4' VC PVI STA = 0+64.00 PVI ELEV = 4897.02 BCVS: 0+52.80BVCE: 4896.96ECVS: 0+75.20EVCE: 4897.16A.D. = 0.75 K = 30.00 EXISTING GROUND PROPOSED GRADE -0.50%0.50% 0.76% 0.50% 1.25% 22.4' VC PVI STA = 0+64.00 PVI ELEV = 4897.02 BCVS: 0+52.80BVCE: 4896.96ECVS: 0+75.20EVCE: 4897.16A.D. = 0.75 K = 30.00 71.0' VC HP ELEV = 4902.65 HP STA = 5+93.22 PVI STA = 5+90.52 PVI ELEV = 4902.78 BVCS: 5+55.02BVCE: 4902.51A.D. = 1.42 K = 50.00 EXISTING GROUND PROPOSED GRADE PROPOSED GROUND EXISTING GROUND PROPOSED GROUND EXISTING GROUND PROPOSED GROUND EXISTING GROUND KEYMAP KECHTER RD (C.R. 36)QUASARWAYR1 PLAN & PROFILEWHEELHOUSE WAY & LOGGERS LANE21 NORTH ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 CENTERLINE WHEELHOUSE WAY/LOGGERS LANE SCALE : 1" = 40' (H) 1" = 4' (V) LEFT FLOWLINE WHEELHOUSE WAY/LOGGERS LANE SCALE : 1" = 40' (H) 1" = 4' (V) RIGHT FLOWLINE WHEELHOUSE WAY/LOGGERS LANE SCALE : 1" = 40' (H) 1" = 4' (V)R1R2STAMATCH LINESEE SHEET6+00R2SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 35 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED EDGE OF ASPHALT PROPOSED STORM MANHOLE / / / / / / / / PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 4.SEE INTERSECTION DETAIL SHEETS FOR INTERSECTION DESIGNS. 5.EXISTING AND PROPOSED MANHOLE RIMS AND VALVE BOX LIDS TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE PROPOSED STORM INLET MATCH STA 6+00LINE CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R T TT GGGGGGGGGG G GGGG G E E EEEE TTE E E E E EE TT TEEEEE E E E E E E EEE EE EEEEEEEEEEETEEEEGGG G GLOGGERS LANECACTUSCURVEWHEELHOUSE WAY QUASAR WAY CACTUS CURVE VAULTELECGASSVAULTELECWCTVCTVCTVCTVCTVCTVEEEEGGGG GGWWSTST STSTSTSTSSSSSSSSSSSSSSSSCTVCTVCTVXXXELECWWWWWWKECHTER ROAD (C.R. 36)(70' PUBLIC ROW)PARCEL W WILLOW BROOK WILLOW BROOK STORM DRAIN LINE A SEE SHEET ST1 STORM DRAIN LINE B SEE SHEET ST2 STORM DRAIN LINE C SEE SHEET ST3 STORM DRAIN LINE D SEE SHEET ST3 STORM DRAIN LINE E SEE SHEET ST3 STORM DRAIN LINE F SEE SHEET ST3 STORM DRAIN LINE G SEE SHEET ST2 SANTARY LINE A-2 SEE SHEET SS2 7 ACCESS EASEMENT 9 UTILITY EASEMENT 9 UTILITY EASEMENT 9 UTILITY EASEMENT 9 UTILITY EASEMENT 14 DRAINAGE EASEMENTKECHTER ROAD (C.R. 36)(70' PUBLIC ROW)4890 4895 4900 4905 4910 4890 4895 4900 4905 4910 6+00 7+00 8+00 9+00 10+00 11+00 11+68 2.00% 8.75%-8.75% -0.86% EXISTING GROUND PROPOSED GRADE 6' WIDE VALLEY PAN 4890 4895 4900 4905 4910 4890 4895 4900 4905 4910 6+00 7+00 8+00 9+00 10+00 11+00 12+00 12+44 4890 4895 4900 4905 4910 4890 4895 4900 4905 4910 6+00 7+00 8+00 9+00 10+00 10+594902.264901.934901.644901.434901.214901.004900.784900.574900.354900.144899.924899.714899.494899.314899.144898.974898.794898.624898.454898.394902.864902.654902.444902.224902.014901.794901.584901.364901.154900.934900.724900.504900.294900.074899.864899.654899.434899.224899.004898.794898.574898.364902.654902.554902.394902.234902.064901.904901.734901.574901.414901.204900.994900.774900.564900.344900.134899.914899.724899.554899.374899.204899.024898.854898.674898.504898.324898.154898.01EXISTING GROUND PROPOSED GRADE EXISTING GROUND PROPOSED GRADE -0.86% -1.49% -0.69% -0.86% -0.70% -0.86% -0.66% PROPOSED GROUND EXISTING GROUND PROPOSED GROUND EXISTING GROUND PROPOSED GROUND EXISTING GROUND KEYMAP KECHTER RD (C.R. 36)QUASARWAYR2 PLAN & PROFILECACTUS CURVE & CACTUS CURVE22 NORTH ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 CENTERLINE CACTUS CURVE/CACTUS CURVE SCALE : 1" = 40' (H) 1" = 4' (V) LEFT FLOWLINE CACTUS CURVE/CACTUS CURVE SCALE : 1" = 40' (H) 1" = 4' (V) RIGHT FLOWLINE CACTUS CURVE/CACTUS CURVE SCALE : 1" = 40' (H) 1" = 4' (V)R1R2SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 35 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED EDGE OF ASPHALT PROPOSED STORM MANHOLE / / / / / / / / PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 4.SEE INTERSECTION DETAIL SHEETS FOR INTERSECTION DESIGNS. 5.EXISTING AND PROPOSED MANHOLE RIMS AND VALVE BOX LIDS TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE PROPOSED STORM INLETSTA MATCH LINESEE SHEET6+00R2MATCH STA 6+00LINE CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R T TGGGGGGGGGGG G EEEE TE E E E E EEE G G GLOGGERS LANEQUASAR WAY CACTUS CURVE MATCH EDGE OF EXISTING VALLEY PAN VAULTELECGASSVAULTELECEGGG GGWW SSSSXXXXPARCEL W WILLOW BROOK PARCEL R WILLOW BROOK STORM DRAIN LINE B SEE SHEET ST2 STORM DRAIN LINE G SEE SHEET ST2 9 UTILITY EASEMENT 9 UTILITY EASEMENT 14 DRAINAGE EASEMENT 4895 4900 4905 4910 4915 4895 4900 4905 4910 4915 0+00 1+00 2+00 EXISTING GROUND PROPOSED GRADE -1.64% -2.00% -2.31%2.31% 2.00% 72.8' VC HP ELEV = 4904.05 HP STA = 1+07.90 PVI STA = 1+04.28 PVI ELEV = 4904.38 BVCS: 0+67.90BVCE: 4903.65EVCS: 1+40.66EVCE: 4903.79A.D. = 3.64 K = 20.00 6' WIDE VALLEY PAN CONNECT TO EXISTING VALLEY PAN 4895 4900 4905 4910 4915 4895 4900 4905 4910 4915 0+00 1+00 2+00 4895 4900 4905 4910 4915 4895 4900 4905 4910 4915 0+00 1+00 2+004901.904902.404902.904903.414903.774903.834903.104902.804903.304903.784904.044903.984901.904902.404902.904903.414903.774903.83PROPOSED GROUND EXISTING GROUND PROPOSED GROUND EXISTING GROUND PROPOSED GROUND EXISTING GROUND EXISTING GROUND PROPOSED GRADE CONNECT TO EXISTING CURB EXISTING GROUND PROPOSED GRADE CONNECT TO EXISTING CURB 2.00% -0.77% 55.3' VC HP ELEV = 4903.85 HP STA = 1+17.02 PVI STA = 1+04.66 PVI ELEV = 4904.00 BVCS: 0+76.98BVCE: 4903.44EVCS: 1+32.33EVCE: 4903.79A.D. = 2.77 K = 20.00 2.00% -0.74% 54.9' VC HP ELEV = 4903.84 HP STA = 1+16.89 PVI STA = 1+04.31 PVI ELEV = 4903.99 BVCS: 0+76.86BVCE: 4903.44EVCS: 1+31.75EVCE: 4903.79A.D. = 2.74 K = 20.00 R3 PLAN & PROFILEQUASAW WAY & ECLIPSE LANE23 NORTH ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 CENTERLINE QUASAR WAY SCALE : 1" = 40' (H) 1" = 4' (V) LEFT FLOWLINE QUASAR WAY SCALE : 1" = 40' (H) 1" = 4' (V) RIGHT FLOWLINE QUASAR WAY SCALE : 1" = 40' (H) 1" = 4' (V)R1R2KEYMAP KECHTER RD (C.R. 36)QUASARWAYSheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 35 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED EDGE OF ASPHALT PROPOSED STORM MANHOLE / / / / / / / / PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 4.SEE INTERSECTION DETAIL SHEETS FOR INTERSECTION DESIGNS. 5.EXISTING AND PROPOSED MANHOLE RIMS AND VALVE BOX LIDS TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE PROPOSED STORM INLET CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R KECHTER ROAD (C.R. 36) (70' PUBLIC ROW) EXISTING BIKE LANE EXISTING BIKE LANE EXISTING THRU LANE EXISTING THRU LANE 7.4 12.7 11.0 13.2 7.5 EXISTING STRIPING 7 EXISTING 11' LEFT TURN LANE ONTO LADY MOON 7 1 3S KECHTER ROAD (C.R. 36) (70' PUBLIC ROW) 7 7 1 7EXISTING STRIPING (TO BE REMOVED) 7 L A EXISTING STRIPING EXISTING BIKE LANE EXISTING BIKE LANE EXISTING THRU LANE PROPOSED THRU LANE PROPOSED TURN LANE 1 7.7 12.4 11.0 13.9 6.9 3S 3S 3S XEXISTING STRIPING (TO BE REMOVED) L A 7 77 EXISTING BIKE LANE EXISTING BIKE LANE EXISTING THRU LANE PROPOSED THRU LANE PROPOSED TURN LANE KECHTER ROAD (C.R. 36) (70' PUBLIC ROW) 1 1 1 1 7 1 6.9 13.0 11.0 14.0 6.8 10.2 5.5 14.6 14.0 7.4 EXISTING TURN LANE EXISTING BIKE LANE EXISTING THROUGH LANE EXISTING THROUGH LANE EXISTING BIKE LANE PROPOSED THROUGH LANE EXISTING BIKE LANE PROPOSED THROUGH LANE PROPOSED BIKE LANE 3S 3S R4 RE-STRIPING PLANKECHTER ROAD24 NORTH ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 KEYMAP KECHTER RD (C.R. 36)QUASARWAYSheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 35MATCH LINE - SEE TOP RIGHTMATCH LINE - SEE BOTTOM LEFTMATCH LINE - SEE TOP RIGHTMATCH LINE - SEE BOTTOM LEFTLEGEND: / / / / / / / /PROPOSED EDGE OF ASPHALT CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) RIGHT-OF-WAY NOTES: LOT LINE 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.REFER TO LANDSCAPE PLANS FOR STREET TREE INFORMATION, AND SURVEY DOCUMENTS FOR ADDITIONAL RIGHT-OF-WAY AND EASEMENT INFORMATION. 3.PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING AND SYMBOLS, THE DEVELOPER SHALL PLACE TEMPORARY TABS OR TAPE DEPICTING ALIGNMENT AND PLACEMENT OF THE SAME. THEIR PLACEMENT SHALL BE APPROVED BY THE CITY OF FORT COLLINS AND TOWN OF TIMNATH TRAFFIC ENGINEERS PRIOR TO PERMANENT INSTALLATION OF STRIPING AND SYMBOLS. YELLOW ISLAND CROSS HATCHING10 WHITE ISLAND CROSS HATCHING 4" SOLID YELLOW LINE 6" SOLID WHITE LINE (2) 4" SOLID LINES; 4" APART DOUBLE YELLOW LINE 4" BROKEN YELLOW LINE 8" SOLID WHITE LINE DOUBLE YELLOW LINE 4" SOLID AND 4" BROKEN; 4" APART 9 6 3 5 1 8 2 4 7 STRAIGHT AND RIGHT TURN ARROW (31 S.F. EA.) PREFORMED PLASTIC PAVEMENT MARKING BICYCLIST AND ARROW 18" X 12' CROSSING LINE, SEE NOTES PREFORMED PLASTIC PAVEMENT MARKING PREFORMED PLASTIC PAVEMENT MARKING 18" WIDE STOP BAR PREFORMED PLASTIC PAVEMENT MARKING "STOP" (22.5 S.F. EA.) PREFORMED PLASTIC PAVEMENT MARKING STRAIGHT AND LEFT TURN ARROW (31 S.F. EA.) PREFORMED PLASTIC PAVEMENT MARKING PREFORMED PLASTIC PAVEMENT MARKING RIGHT TURN ARROW (15.5 S.F. EA.) PREFORMED PLASTIC PAVEMENT MARKING LEFT TURN ARROW (15.5 S.F. EA.) RIGHT AND LEFT TURN ARROW (31 S.F. EA.) PREFORMED PLASTIC PAVEMENT MARKING TWO WAY LEFT TURN ARROW (31 S.F. EA.) PREFORMED PLASTIC PAVEMENT MARKING PREFORMED PLASTIC PAVEMENT MARKING "ONLY" (22.5 S.F. EA.) L H D C B KA E F G I J M LANE REDUCTION ARROW PREFORMED PLASTIC PAVEMENT MARKING MEDIAN LINE YELLOW 18" WIDE1150' O.C. 45° ANGLES 10'30'10'30'10'4" BROKEN WHITE12 10' N "LANE ENDS" PREFORMED PLASTIC PAVEMENT MARKING 3'9'3'9'3'4" WHITE DASHED LINE O 18" WIDE WHITE MEDIAN STRIPING PREFORMED PLASTIC PAVEMENT MARKING A.ALL SIGNAGE AND MARKING IS SUBJECT TO THE GENERAL NOTES ON THE COVER SHEET OF THESE PLANS, AS WELL AS THE TRAFFIC SIGNING AND MARKING CONSTRUCTION NOTES LISTED HERE. B.ALL SYMBOLS, INCLUDING ARROWS, ONLYS, CROSSWALKS, STOP BARS, ETC. SHALL BE PRE-FORMED THERMO-PLASTIC. C.ALL SIGNAGE SHALL BE PER TOWN OF TIMNATH AND CITY OF FORT COLLINS STANDARDS AND THESE PLANS OR AS OTHERWISE SPECIFIED IN MUTCD. (REF. LCUASS SECTION 22.6.2) D.ALL LANE LINES FOR ASPHALT PAVEMENT SHALL RECEIVE TWO COATS OF LATEX PAINT WITH GLASS BEADS. E.ALL LANE LINES FOR CONCRETE PAVEMENT SHALL BE EPOXY PAINT. F.PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING AND SYMBOLS, THE DEVELOPER SHALL PLACE TEMPORARY TABS OR TAPE DEPICTING ALIGNMEMT AND PLACEMENT OF THE SAME. THEIR PLACEMENT SHALL BE APPROVED BY THE CITY OF FORT COLLINS AND TOWN OF TIMNATH ENGINEERS PRIOR TO PERMANENT INSTALLATION OF STRIPING AND SYMBOLS. G.PRE-FORMED THERMO-PLASTIC APPLICATIONS SHALL BE AS SPECIFIED IN THESE PLANS AND/OR THESE STANDARDS. H.EPOXY APPLICATIONS SHALL BE APPLIED AS SPECIFIED IN CDOT STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION. I.ALL SURFACES SHALL BE THOROUGHLY CLEANED PRIOR TO INSTALLATION OF STRIPING OR MARKINGS. J.ALL SIGN POSTS SHALL UTILIZE BREAK-AWAY ASSEMBLIES AND FASTENERS PER THE STANDARDS. K.A FIELD INSPECTION OF LOCATION AND INSTALLATION OF ALL SIGNS SHALL BE PERFORMED BY THE CITY OF FORT COLLINS AND TOWN OF TIMNATH ENGINEERS. ALL DISCREPANCIES IDENTIFIED DURING THE FIELD INSPECTION MUST BE CORRECTED BEFORE THE 2-YEAR WARRANTY PERIOD WILL BEGIN. L.THE DEVELOPER INSTALLING SIGNS SHALL BE RESPONSIBLE FOR LOCATING AND PROTECTING ALL UNDERGROUND UTILITIES. M.SPECIAL CARE SHALL BE TAKEN IN SIGN LOCATION TO ENSURE AN UNOBSTRUCTED VIEW OF EACH SIGN. N.SIGNAGE AND STRIPING HAS BEEN DETERMINED BY INFORMATION AVAILABLE AT THE TIME OF REVIEW. PRIOR TO INITIATION OF THE WARRANTY PERIOD, THE CITY OF FORT COLLINS AND TOWN OF TIMNATH RESERVE THE RIGHT TO REQUIRE ADDITIONAL SIGNAGE AND/OR STRIPING IF THE CITY OF FORT COLLINS AND TOWN OF TIMNATH DETERMINE THAT AN UNFORESEEN CONDITION WARRANTS SUCH SIGNAGE ACCORDING TO THE MUTCD OR THE CDOT M AND S STANDARDS. ALL SIGNAGE AND STRIPING SHALL FALL UNDER THE REQUIREMENTS OF THE 2-YEAR WARRANTY PERIOD FOR NEW CONSTRUCTION (EXCEPT FAIR WEAR ON TRAFFIC MARKINGS). O.SLEEVES FOR SIGN POSTS SHALL BE REQUIRED FOR USE IN ISLANDS/MEDIANS. REFER TO CHAPTER 14, TRAFFIC CONTROL DEVICES, FOR ADDITIONAL DETAIL. P.STREET NAME SIGNS AT INTERSECTIONS SHALL BE INSTALLED ABOVE STOP SIGNS ON SAME POLE, PER LCUASS DRAWING 1401. STRIPING LEGEND:STRIPING NOTES: 3'9'3'9'3'8" WHITE DASHED LINE (NOTE: ALL ITEMS MAY NOT APPLY TO THIS PLAN) PAVEMENT STRIPING PAVEMENT MARKINGS STRAIGHT ARROW (15 S.F. EA.) PREFORMED PLASTIC PAVEMENT MARKING 30'10'30'10' EASEMENT R4 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R PARKING NO ANY ITME PARKING NO ANY ITME PARKING NO ANY ITME SITE SIGN LEGEND 1S 2S 3S D1 SITE DETAILS25 SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 35 100 101 STREET INTERSECTION CROSSPAN ASPHALT PAVING DETAIL (CROSSPAN)102 SIGN POST103 104 SECTION A-APAVEMENT DESIGN + 1/2" FOR COLLECTOR8" MIN. FOR RESIDENTIAL. USE CONCRETE10' MINIMUM (ARTERIAL)8' MINIMUM (COLLECTOR)PLAN VIEW6' MINIMUM (LOCAL)COLD JOINT (See Standard Drawing 714)AT 10' O.C.TOOL JOINTFOR PANS OVER 40'CONTROL JOINT REQUIREDCONTROLROADWAY WIDTHALL INTERSECTIONS TOHAVE ACCESS RAMPSNOTE:**& ARTERIALS.SIDES.TO PAN SECTION, TYPICAL BOTHTRANSITION FROM C & G SECTIONWALK8'DOWELL IFJOINTSTOOL JOINTAAJOINTS (TYP.)CONTROLPARALLELSTREETCLASSIFICATIONLOVELANDDEPTH OF INVERTWWIDTHCROSS PANArterial10'1 1/4"1 1/2"Collector8'1"1 1/8"Local6'3/4"7/8"d (MAX.)d (MIN.)1 1/2"2 1/2"2"DEPTH OF INVERTFT. COLLINSdd8' MIN. WIDTH WHERE CROSSING A COLLECTOR ROADWAY.****LENGTH(for monolithic pour)THICKNESS ASPHALT DESIGNED 2T*W ASPHALT 2T*WT W P.C. CROSSPAN THICKENED ASPHALT THICKENED ASPHALT THICKNESS DESIGNED AND WALK CURB, GUTTER T = THICKNESS OF CROSSPAN W = WIDTH OF CROSSPAN P.C. *-If subgrade is flyash treated, use T instead of 2T. Max. Sign Panel 1. Attach the sign panels tightly to the post and use oversized washers to keep the sign from breaking loose from the post when hit by a vehicle. 2. Sign panels should be mounted a minimum of 7 feet above the pavement or ground. Cross section of post 3" - 6" ABOVE GRADE 2 1/4" Anchor 3. Signs larger than 36 inches in length or width require wind bracing and special post design. NOTES: 4. Anchor Stub and post are square steel tube (perforated). Anchor/Stub Post Size CRITERIA FOR SINGLE POST 36" x 36"2.25" x 2.25" x 3'-0"2" x 2" x 12'-0" 5. All "No Parking" signs shall be installed at 45° from Flow Line. ** 2" x 2" x 10' OR 12' 12 GAUGE TELESPAR POST (22F12A31)7'-0" MIN. CLEARANCE2' - 3' FROM F Street Curb See Figure 16-1 SW SAMPLEAVE 2400 R1-1 "STOP" SIGN 30" HIGH DENSITY/DIAMOND GRADE. SIGN MOUNTED TO POST WITH 1 EACH DRIVE RIVET WITH NYLON WASHER AGAINST SIGN FACE (ON TOP OF THE SIGN). THE BOTTOM OF THE SIGN SHALL BE MOUNTED WITH 1 EACH 5/16"x2-1/2" HEW BOLT WITH METAL AND FROM NYLON WASHERS (NYLON WASHER AGAINST SIGN FACE) AND SECURED WITH 1 EACH 5/16" HEX NUT ON THE BACK SIDE OF POST.L 2-1/4" x 2-1/4" x 3' ANCHOR/STUB 2 EACH 8" BLADES MOUNTED TO POST WITH 4 EACH DRIVE RIVETS WITH NYLON WASHERS *12 Gauge 30"8"8"7 3/8" (L)1 3/8"17"6"3 3/8"14"FLR 16"R 16"DRIVE-OVER CURB, GUTTER AND DETACHED SIDEWALK31"See Drawing 160110 3/4"(L)R 16"DRIVE-OVER CURB, GUTTER AND ATTACHED SIDEWALK 18"18"3 3/8"1 3/8"6"R 16"FL14"6"17"1 1/2"5' (L)8 5/8" (F.C.)7 1/4" F.C.12" (F.C.)Slope to curb 1/4"/Ft.1' min. (F.C.)48:1 min.4:1 max.ExcavationFill1' min.2' min.1/4"/Ft.CURB & GUTTER IN A CUT OR FILL6"3'-9" (F.C.)For Thickness2' min. (L)CURB AND GUTTER / SIDEWALK STANDARD SIDEWALK Sidewalk Sidewalk Standard Street Sign NOTE: 1. All above ground utilities or other features must be a minimum of 2' from sidewalk. * The minimum horizontal clearance may be reduced by the Local Entity Engineer to zero feet in locations such as downtown, special pedestrian plazas and bridges, where bicycle traffic is restricted. In such locations the minimum clear path equal to the standard sidewalk width for the street classification shall be clear of all obstructions. Min. 7' Clearance Min. 2' Min. 8' Clearance * Minimum Hor. Clear DETACHED SIDEWALK SECTION ATTACHED SIDEWALK SECTION Standard Width * Minimum Hor. Clear Standard Width * Min. Hor. Clear Fixed Object: Pole Sign Post, Hydrant, Bridge Railing Objects & Materials Trees Shrubs, Hedges Fences & Walls Solid Fixed Objects Movable Solid Objects Gravel, Rocks, or Material that may slough or land on the sidewalk Minimum Horizontal Clearance 2.5' 2' 1' 1' 2' CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R 105 PAVING SECTIONS NOTES: ALL SITE GRADING, SUBGRADE PREPARATION AND PAVING SHALL FOLLOW THE GEOTECHNICAL RECOMMENDATIONS CONTAINED IN THE "GEOTECHNICAL ENGINEERING REPORT ELIZABETH STREET PROJECT 1208 AND 1220 WEST ELIZABETH STREET, FORT COLLINS, COLORADO" BY TERRACON CONSULTANTS, INC., PROJECT NO. 20165099 DATED NOVEMBER 18, 2016, AND ANY SUBSEQUENT ADDENDA. 1.REFER TO PLANS BY RIPLEY DESIGN, INC. FOR ADDITIONAL HARDSCAPE INFORMATION. 2.CONCRETE JOINTING SHALL CONFORM TO CDOT DETAIL M-412-1 OR APPROVED EQUAL. 3.FOLLOW MANUFACTURER'S RECOMMENDATIONS FOR PAVER SECTION AND INSTALLATION. (NOTE: SECTION SHALL MEET THE SAME STRUCTURAL REQUIREMENTS AS 'HEAVY DUTY' ABOVE) 4.THE ENTIRE PERIMETER OF THE PERMEABLE PAVER AREAS SHALL RECEIVE SOME FORM OF EDGE RESTRAINT. FOLLOW MANUFACTURER'S RECOMMENDATIONS AND DETAILS ON THIS SHEET. 5.NOTE THAT THESE PAVING SECTIONS ARE TO BE USED ONLY FOR AREAS OUTSIDE OF PUBLIC RIGHT-OF-WAY. PAVING SECTIONS WITHIN PUBLIC RIGHT-OF-WAY WILL BE REQUIRED BY THE CITY OF FORT COLLINS TO BE PER AN APPROVED PAVEMENT DESIGN REPORT. 4" CONCRETE PRIVATE CONCRETE FLATWORK PAVEMENT SECTION PUBLIC CONCRETE FLATWORK PAVEMENT SECTION CONCRETE FLATWORK SECTIONS VEHICULAR PAVING SECTIONS ASPHALT PAVEMENT SECTION 6" HOT BITUMINOUS PAVEMENT (S OR SX) ASPHALT PAVEMENT SECTION 7" HOT BITUMINOUS PAVEMENT (S OR SX) 7" APPROVED SUBGRADE 8" APPROVED SUBGRADE 4" HOT BITUMINOUS PAVEMENT (S OR SX) 5" HOT BITUMINOUS PAVEMENT (S OR SX) 6" CONCRETE PRIVATE CONCRETE PAVEMENT SECTION D2 SITE DETAILS26 SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 35 200 201 202 203SIDEWALK DETAIL STREET ACCESS RAMPSTRUNCATED DOME WARNING DIRECTIONAL ACCESS RAMP DETAIL & DETACHED SIDEWALK ATTACHED SIDEWALK DETAIL Slope sidewalk to curb 1/4" per foot. NOTE: Construct sidewalk with joints at 10' intervals R 1/8" WEAKENED PLANE JOINT EXPANSION JOINT R1/4" and aligned with scoring on curb. INSTALL IN LOCATIONS SPECIFIED IN CHAPTER 22 1/2" 1/4"1/4 SLAB THICKNESS 1/4" 1/2" Expansion Joint material DETACHED SIDEWALK DETAIL Variable Landscaping Slope sidewalk to curb 1/4" per foot. 2' min. Slope: Minumum 1 4"/ft Maximum 3"/ft Radius = 8" 1. No joints are allowed in the flowline. Six inch wide curb or "dummy joint" may be tooled no closer than 6 inches from flow line as shown. 2. Pedestrian landing area required 4 ft length x 4 ft width, max slope in any direction is 1:50 or 14" per foot. 3. Joint pattern to be according to intersection gutter detail' or as determined by the local entity. 4. Wood float finish is required over the sloped surface of ramp and flares. 5. A 6" wide curb option may be poured along side of the ramp as shown if required. If curb is used it shall match style of adjacent curb and gutter. 6. Minimum ramp width shall be four feet, or the same as the widest adjacent sidewalk, whichever is greater, up to a maximum width of 8 feet. 7. Detectable warning is to extend full width of the ramp and be a minimum of 2.0' in the direction of travel. Material to be approved by local engineer 8. T = Concrete thickness, 6" minimum for entire ramp area. SECTION A-A PLAN VIEW N.T.S. N.T.S. NOTES: 2' Transition (TYP.) 4' (min) 6" 2' 1:20 (max) 1:12 (m a x )  T, See Note 8 0" Curb  Lip of Gutter Detectable Warning A A 1/2" per ft. 1" per ft. Flare Curb Flare Detectable Warning Curb Option, See Note 5 Curb (TYP.)SIDEWALK SIDEWALK0" Curb Height, See Section A-A (TYP) Standard Curb and Gutter, See Standard Dwg 701 (TYP) Pedestrian Landing Area, See Note 2 2' (min) FORT COLLINS ONLY Notes: 1. Set ramp slopes using the center of theramp. 2. Truncated dome warning panel: Install panels along with the concrete pour for theramp. Specifications for the panel materialwill be provided upon request. 3. Each ramp shall align perpendicular to thestreet in which the ramp is provided to cross. 4. Refer to standard drawing 1606 in the Laimer County urban area street standardsfor other necessary criteria needed to construct these ramps that is not specifiedon this drawing. 5. Construct the ramps and walk so the cornerarea all drains to the street. 6. If curb and gutter are poured monolithic withramp, place dome edge at back of curb asshown. If not poured monolithic, place dome edge 6" from back of curb.PLAN VIEWNTSRamp FlareGutterRampRampFlareCurbCurbConc. FlarePanelsPanelsTruncated domepanels:1-2'x2.5'1-2'x2'Truncated Dome WarningDetection Plan LocationsLEGEND:BOC- Back of curb⅊ Property LinePT - Point of TangencyFlow line Section A-A NTS4'-6"2'-0"2'-6"2'-0"t Varies Varies 4.5'6.0'.5'1.5'4.5'1.5 '12.0'12.0'4.5'.5'6.0'4.5'L a n d s c a p e d A r e a PT CurbAA6" Curb(TYP)0" CurbFull heightcurbTruncated domewarning detection⅊PT of walkR15.0'⅊⅊ & BOW5'-6" BOC to walk w/ vertical curb5'-7" BOC to walk w/ drive over curbConc. SidewalkArea to be landscapedConc. walkGutterorApronTruncate DomeWarning Panel1:12 Max slope1:20SlopePT of curbreturn6"Conc. Flare6" Curb(TYP)See note 6 CurbFlareVaries CurbFlareRampCurbCurb FlareRampVaries PanelsPanels6"RampWidth:4.5'5.0'6.0'7.0'8.0'Note:Truncated dome panels areavailable in 2'x2' squaresand 2'x2.5' rectangles.Combine the widths to fitthe ramp. Panels may becut to no less than a 2'x1.5'size.Panel WidthCombinations:2'+2.5'2.5'+2.5'2'+2'+2'2.5'+2'+2.5'2'+2'+2'+2'Notes: 1. Truncated dome warning panel: Install panels along with the concrete pour for the ramp. Specifications for the panel and installation instructions will be provided upon request. 2. This drawing shows vertical curb.For Drive Over Curb the warning detection location shall be placed inthe same position 6" back from theback of curb. 3. If curb and gutter are poured monolithic with ramp, place domeedge at back of curb as shown. Ifnot poured monolithic, place domeedge 6" from back of curb.Case 1-Directional RampsCase 2-Non-Directional RampsVaries PanelsRampPanelsFlareCurbCase 3-Mid-Block Ramps6"PanelsPanelsFlare6"FlareVaries FORT COLLINS ONLY Aligned with Pedestrian flow GutterorApron℄Center line of rampBOC-Back of CurbFOC -Face of Curb-Flow lineVaries 2'-0" 2'-0"AAFOC or ℄ 2'-0"BOCBOC1:12 max slope1:20slopePanels embedded in theconcrete ramps Section A-A (Center line of ramp)NTSFlow line Curb and Gutter BOC See Note 3 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R D3 UTILITY DETAILS27 SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 35 300 TRENCH AND BEDDING 301 302 303GATE VALVE SINGLE METER PIT 304 305 FIRE HYDRANT DOUBLE METER PIT UTILITY SERVICE LOCATION CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R D4 UTILITY DETAILS28 SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 35 400 401 402 403OUTSIDE-DROP MANHOLE TYPICAL MANHOLE GROUNDWATER BARRIER C:\Work\MAPPING\BLOCKS\Logos\SS-New\SFCSD.bmp 404 405 SANITARY SEWER SERVICE CONNECTION TRENCH AND BEDDING UTILITY SERVICE LOCATION CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R D5 DRAINAGE DETAILS29 SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 35 504 METAL END SECTIONS502 SIDEWALK CHASE CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R 500 DOUBLE CURB INLET AA B B A A SECTION B-B DETAIL 1 SECTION A-A PLAN SECTION C-C CC BB A A AA B B A A 501 SINGLE CURB INLET INLINE DRAIN503 D6 DRAINAGE DETAILS30 SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 35 602 EDB OUTLET STRUCTURE EXTENDED DETENTION BASIN600 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R CC A A B B D D SECTION A-A SECTION B-B WELL SCREEN FLOW CONTROL PLATE SECTION D-D ABBREVIATIONS PLAN SECTION C-C GENERAL NOTES SECTION E-E 100-YEAR ORIFICE PLATE DETAIL E E RAIN GARDEN601 FLOW LENGTH > IN THE BOTTOM OF THE BASIN PROVIDE A 3% MIN. SLOPE TO THE TRICKLE CHANNEL OR MICROPOOL. SEE EDB OUTLET STRUCTURE DETAIL SEEPAGE CUTOFF COLLAR (IF NECESSARY)WPERMEABLE GEOTEXTILE LINER TO TOP OF BANK 24" NYLOPLAST DRAIN BASIN/ W/ DOME GRATE SEE TABLE VAULT ELEC VAULT ELEC GAS S VAULT ELEC FES CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR LID S VAULT ELEC FE SD S S SS CONTROL IRR CONTROL IRR CONTROL IRR D E VAULT ELEC T VAULT ELECCXXX XXXXXXXXXXX X X X X X X XXXXXXELECT TTTEEEEEETTEEEEEEE ETT T EEEEEEEEEEEEEEEEEEEEEEEEEE E EEE EEEEEEEEEEETE EE EEE EE ECF CF CF CF CF CF CF CFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCF CF CF CF CF CF PARCEL X WILLOW BROOK PARCEL W WILLOW BROOK PARCEL R WILLOW BROOK POUDRE R-1 SCHOOL DISTRICT PARCEL NO. 8604000904 ECLIPSE LANE (53' PUBLIC ROW) KECHTER ROAD (C.R. 36) (70' PUBLIC ROW)CACTUS CURVE(53' PUBLIC ROW)CACTUS CURVE (53' PUBLIC ROW)WHEELHOUSE WAY(53' PUBLIC ROW)QUASAR WAY(53' PUBLIC ROW)LOGGERS LANE (53' PUBLIC ROW)SFSF SF SF SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSF SF SF SF SF SF SF SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSF SF SF SF SF SF MATCH LINE - SEE SHEET EC3 TYP. TYP. TYP. TYP. MATCH LINE - SEE SHEET EC2 EC1 OVERALL EROSION CONTROL PLAN31 NORTH ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 35 KEYMAP KECHTER RD (C.R. 36)QUASARWAYEC2 EC3 LEGEND: PROPOSED CONTOUR PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED INLET ROCK SOCK INLET PROTECTION VEHICLE TRACKING CONTROL PAD SILT FENCE SF 1.CONTRACTOR SHALL IMMEDIATELY STABILIZE ALL DISTURBED SLOPES BY CRIMP MULCHING OR SIMILAR METHODS. 2.SWMP ADMINISTRATOR: Contact ________________________________ Company ________________________________ Address ________________________________ Phone ________________________________ 3.CONTRACTOR TO PROVIDE VEHICLE TRACKING CONTROL FOR CONCRETE WASHOUT AREA IF ACCESS IS OFF PAVEMENT. 4.REFER TO THE "PRELIMINARY DRAINAGE AND EROSION CONTROL REPORT FOR "KECHTER TOWNHOMES" BY NORTHERN ENGINEERING, DATED JULY 22, 2020 FOR ADDITIONAL INFORMATION. 5.HYRDOMULCH ALL SLOPES 6:1 OR GREATER WHERE RUNON IS ANTICIPATED OR SLOPE AREA IS LONGER THAN 50'. INSTALL ECF WHERE HYDROMULCH DOES NOT CONTROL EROSION TO THE SATISFACTION OF THE INSPECTOR. 6.SEDIMENTATION BMP FREQUENCY IS SCHEMATIC. ADD BMPs AS NEEDED TO ENSURE NO GREATER THAN 2% SLOPE FROM BOTTOM OF UPSTREAM TO TOP OF DOWNSTREAM STRUCTURE. GENERAL NOTES: WATTLE DIKE CONCRETE WASH AREA OUTLET PROTECTION CONSTRUCTION FENCE CF CF NOTE: ALL BMPS SHOWN ON THIS PLAN ARE GRAPHIC REPRESENTATIONS ONLY. FINAL DETERMINATION OF SIZE AND LOCATION SHALL BE DETERMINED BY THE CONTRACTOR AND DOCUMENTED ON THE DYNAMIC SITE PLAN. CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R VAULT ELEC VAULT ELEC GAS S VAULT ELEC FES CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR LID CONTROL IRR CONTROL IRR CONTROL IRRXX XXXXXXXXXXXXXXXX X X X X X X X X X X X X X XXXXXXXXXXXTTTTEEEEEEEEEEEETE TEEEEEEEEEEEEEE E EEEE E E EEEEEE E EE E EEEEEE E E EEELOGGERS LANE WHEELHOUSE WAYCF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCF CF CF CF CF CF CF CF CF CF CF WHEELHOUSE WAYCACTUS CURVE6' UTILITY & DRAINAGE EASEMENT 6' DRAINAGE EASEMENT 9' UTILITY EASEMENT PARCEL X WILLOW BROOK PARCEL W WILLOW BROOK PARCEL R WILLOW BROOK POUDRE R-1 SCHOOL DISTRICT PARCEL NO. 8604000904 ECLIPSE LANEQUASAR WAYSFSFSFSF SF SF SF S F SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSF SF SF SF SF SF SF SF SF SF SF SF SF SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSF SF SF SF SF SF SF SF SF SF SF SF SF MATCH LINE - SEE SHEET EC3 TYP. TYP. MATCH LINE - SEE SHEET EC2 EC2 EROSION CONTROL PLAN32 NORTH ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 35 KEYMAP KECHTER RD (C.R. 36)QUASARWAYEC2 EC3 MATCH LINE - SEE SHEET EC3 LEGEND: PROPOSED CONTOUR PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED INLET ROCK SOCK INLET PROTECTION VEHICLE TRACKING CONTROL PAD SILT FENCE SF 1.CONTRACTOR SHALL IMMEDIATELY STABILIZE ALL DISTURBED SLOPES BY CRIMP MULCHING OR SIMILAR METHODS. 2.SWMP ADMINISTRATOR: Contact ________________________________ Company ________________________________ Address ________________________________ Phone ________________________________ 3.CONTRACTOR TO PROVIDE VEHICLE TRACKING CONTROL FOR CONCRETE WASHOUT AREA IF ACCESS IS OFF PAVEMENT. 4.REFER TO THE "PRELIMINARY DRAINAGE AND EROSION CONTROL REPORT FOR "KECHTER TOWNHOMES" BY NORTHERN ENGINEERING, DATED JULY 22, 2020 FOR ADDITIONAL INFORMATION. 5.HYRDOMULCH ALL SLOPES 6:1 OR GREATER WHERE RUNON IS ANTICIPATED OR SLOPE AREA IS LONGER THAN 50'. INSTALL ECF WHERE HYDROMULCH DOES NOT CONTROL EROSION TO THE SATISFACTION OF THE INSPECTOR. 6.SEDIMENTATION BMP FREQUENCY IS SCHEMATIC. ADD BMPs AS NEEDED TO ENSURE NO GREATER THAN 2% SLOPE FROM BOTTOM OF UPSTREAM TO TOP OF DOWNSTREAM STRUCTURE. GENERAL NOTES: WATTLE DIKE CONCRETE WASH AREA OUTLET PROTECTION CONSTRUCTION FENCE CF CF NOTE: ALL BMPS SHOWN ON THIS PLAN ARE GRAPHIC REPRESENTATIONS ONLY. FINAL DETERMINATION OF SIZE AND LOCATION SHALL BE DETERMINED BY THE CONTRACTOR AND DOCUMENTED ON THE DYNAMIC SITE PLAN. TYP. TYP. CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R S VAULT ELEC FES D S S D E VAULT ELEC T XXXXXXXXXXXXXXXXXXXXELEC TTEEEETT T EEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE E E EEE E EEEEEEEEEEEEEEEEEEEEEEETE EEE EEEEE EEE EECACTUS CURVEWHEELHOUSE WAYCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCACTUS CURVE14' DRAINAGE EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT PARCEL X WILLOW BROOK CITY OF FORT COLLINS PARCEL NO. 8609128901 POUDRE R-1 SCHOOL DISTRICT PARCEL NO. 8604000904 KECHTER ROAD (C.R. 36) (70' PUBLIC ROW)SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSF SF SF SF SF SF SF SF SF SF SF SF SF SF SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSF SF SF MATCH LINE - SEE SHEET EC3 TYP. TYP. MATCH LINE - SEE SHEET EC2 EC3 EROSION CONROL PLAN33 NORTH ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 35 KEYMAP KECHTER RD (C.R. 36)QUASARWAYTYP. LEGEND: PROPOSED CONTOUR PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED INLET ROCK SOCK INLET PROTECTION VEHICLE TRACKING CONTROL PAD SILT FENCE SF 1.CONTRACTOR SHALL IMMEDIATELY STABILIZE ALL DISTURBED SLOPES BY CRIMP MULCHING OR SIMILAR METHODS. 2.SWMP ADMINISTRATOR: Contact ________________________________ Company ________________________________ Address ________________________________ Phone ________________________________ 3.CONTRACTOR TO PROVIDE VEHICLE TRACKING CONTROL FOR CONCRETE WASHOUT AREA IF ACCESS IS OFF PAVEMENT. 4.REFER TO THE "PRELIMINARY DRAINAGE AND EROSION CONTROL REPORT FOR "KECHTER TOWNHOMES" BY NORTHERN ENGINEERING, DATED JULY 22, 2020 FOR ADDITIONAL INFORMATION. 5.HYRDOMULCH ALL SLOPES 6:1 OR GREATER WHERE RUNON IS ANTICIPATED OR SLOPE AREA IS LONGER THAN 50'. INSTALL ECF WHERE HYDROMULCH DOES NOT CONTROL EROSION TO THE SATISFACTION OF THE INSPECTOR. 6.SEDIMENTATION BMP FREQUENCY IS SCHEMATIC. ADD BMPs AS NEEDED TO ENSURE NO GREATER THAN 2% SLOPE FROM BOTTOM OF UPSTREAM TO TOP OF DOWNSTREAM STRUCTURE. GENERAL NOTES: WATTLE DIKE CONCRETE WASH AREA OUTLET PROTECTION CONSTRUCTION FENCE CF CF NOTE: ALL BMPS SHOWN ON THIS PLAN ARE GRAPHIC REPRESENTATIONS ONLY. FINAL DETERMINATION OF SIZE AND LOCATION SHALL BE DETERMINED BY THE CONTRACTOR AND DOCUMENTED ON THE DYNAMIC SITE PLAN. TYP. EC2 EC3 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R MATCH LINE - SEE SHEET EC2 EC4 EROSION CONROL DETAILS34 SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 35 000 SILT FENCE 001 002 003CONSTRUCTION FENCE VEHICLE TRACKING CONTROL PAD INLET PROTECTION 004 WATTLE DIKE 005 OUTLET PROTECTION TEMPORARY CHAIN-LINK FENCE ROCK SOCK TEMPORARY CHAIN-LINK FENCE ROCK SOCK SIDE VIEW CF X CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R GAS CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR S VAULT ELEC W FE S D S SS HY DCONTROL IRR CONTROL IRR CONTROL IRR D E VAULT ELEC T VAULT ELECCXGTTE EWW W W W W WT T T E E E E E XXXXXXXXXXXXXXE E EX G G G G G GWST ST ST ST ST ST ST ST ST ST ST ST STSTSS SS SS SS SS SS SS SS SSSSSS SS SSXX X X X X X X X X XXXXXXXXXELEC WWEXTENDED DETENTION BASIN REQUIRED VOL=35,316 CF PROVIDED VOL=36,028 CF CHASE DRAIN A.2 STORM SEWER D POND OUTLET STORM SYSTEM W/ INLINE DRAINS PROPOSED SWALE PROPOSED SWALE PROPOSED SWALE STORM SEWER A RAIN GARDEN OUTLET ECLIPSE LANE CACTUSCURVE)QUASAR WAYPROPOSED CULVERT (IRRIGATION DITCH) PARCEL X WILLOW BROOK PARCEL W WILLOW BROOK PARCEL R WILLOW BROOK POUDRE R-1 SCHOOL DISTRICT PARCEL NO. 8604000904 CURB & GUTTER (TYP.)EX DRIPLINE CANOPY (AREA UNDEERNEATH TO REMAIN UNDISTURBED) TAPER TOP WALL TAPER TOP WALL EX DRIPLINE CANOPY (AREA UNDEERNEATH TO REMAIN UNDISTURBED) CURB INLET E.1 STORM SEWER A STORM SEWER B A.2 0.85 AC C.1 0.62 AC C.2 0.35 AC C.3 0.52 AC C.5 0.63 AC C.4 0.07 AC A.1 0.49 AC RAIN GARDEN B 6' DRAINAGE & UTILITY EASEMENT 6' DRAINAGE & UTILITY EASEMENT 6' DRAINAGE & UTILITY EASEMENT TRACT D DRAINAGE EASMENT RAIN GARDEN A TRACT C DRAINAGE EASEMENT TRACT B DRAINAGE EASMENT A B C B.2 0.41 AC B.1 0.75 AC CURB INLET B.1 CURB INLET B.2 CHASE DRAIN B.1 CURB INLET D.1 12" RCP 12" RCP 14' DRAINAGE EASEMENT FOR DRAINAGE REVIEW ONLY NOT FOR CONSTRUCTION HYDROLOGY SUMMARY CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NORTH LID SUMMARY EXTENDED DETENTION BASIN SUMMARY A 1.62 AC LEGEND: PROPOSED CONTOUR PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED INLET ADESIGN POINT FLOW ARROW DRAINAGE BASIN LABEL DRAINAGE BASIN BOUNDARY PROPOSED SWALE SECTION 11 NOTES: 1.REFER TO THE FINAL DRAINAGE REPORT FOR WILLOW BROOK, JULY 27, 2001 BY TST, INC. CONSULTING ENGINEERS FOR ADDITIONAL INFORMATION. UDPROPOSED UNDERDRAIN BENCHMARK PROJECT DATUM: NAVD88 BENCHMARK #1: City of Fort Collins Benchmark 2-03 Location: South side Kechter Road approximately 0.6 miles west of Strauss Cabin Road on the east end of the south parapet wall of the bridge over the Dixon Canyon Lateral. Elevation= 4898.14 (NAVD88) BENCHMARK #2: City of Fort Collins Benchmark 13-13 Location: On the west side of Strauss Cabin Road, approximately 90-ft south of Kechter Road, on the northwest corner of a storm inlet. Elevation= 4887.05 (NAVD88) Please note: This plan set is using NAVD88 for a vertical datum. Surrounding developments have used NGVD29 Unadjusted Datum (prior City of Fort Collins Datum) for their vertical datums. If NGVD29 Unadjusted Datum (prior City of Fort Collins Datum) is required for any purpose, the following equation should be used: NGVD29 Unadjusted Datum (prior City of Fort Collins Datum) = NAVD88 - 3.18' Basis of Bearings South line of the Southeast Quarter of Section 4-6-68 as bearing South 88°11'39" East. EXISTING NATURAL HABITAT BUFFER ZONE PROPOSED NATURAL HABITAT BUFFER ZONE EXISTING WETLAND SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 35 DR1 DRAINAGE EXHIBIT35 DESIGN POINT SUMMARY