HomeMy WebLinkAboutHEALTHCARE INTERNATIONAL AT OAK RIDGE WEST - PRELIMINARY - 23-87A - - CORRESPONDENCE-CONCEPTUAL REVIEW1 CITY OF FORT COLLINS OFFICE OF DEVELOPMENT SERVICES, PLANNING DEPARTMENT April 16, 1987 Mr. Wi ley Barnes c/o Healthcare International 2.135 Southgate Road Colorado Springs, CO 80906 Dear Wiley, For your information, attached is a copy of the Staff's comments concerning Healthcare International, Inc.- Health Facility, which was presented before the Conceptual Review Team on April 13, 1.987. The comments are offered informally by Staff to assist you in preparing the detailed components of the project application. Modifications and addi- tions to these comments may be made at the time of formal review of this proj ect . If you should have any questions regarding these comments or the next steps in the review process, please feel free to call me at 221-6750. Si ncere ly, ,,4,44k Debbie deBesche Project Planner Attachment Dd6/bh xc: Tom Peterson, Director of Planning Mike Herzig, Development Coordinator Jim. Newell, Civil Engineer I Project Planner File OFFICE OF DEVELOPMENT SERVICES, PLANNING 300 LaPorte Ave. C P.O. Box 580 • Fort Collins, Colorado 80522 • (303) 221.6750 CONCEPTUAL REVIEW STAFF COMMENTS MEETING DATE: April 13, 1987 ITEM: Healthcare International, Inc. - Health Facility APPLICANT: Mr. Wiley Barnes, Healthcare International, 2.135 Southgate Road, Colorado Springs, CO 80906 LAND USE DATA: Request for a 45,000 - 5n,00o square foot health care facility on approximately 13 acres. The proposed project is located south of Harmony Road and adjacent to and west of Lemay Avenue and is zoned, RP, Planned Residential. COMMENTS: 1. The City can provide light and power to the site. The existing over head power lines on the west side of Lemay wi 11 need to be placed underground. A commercial one form will need to be filled out by the applicant . Please contact the City Light and Power office at 221-6700 regarding development charges. 2. The placement of the light and power transformers is important in regard to accessibility for maintenance. The access will have to be. of a hard -surface material. 3. A utility coordination meeting is recommended, please contact Mike Her- zig, Development Coordinator, at 221-6750 to schedule a meeting. 4. The storm drainage for the site requires a maximum release rate of .02 C.F.S. per acre. 5. Foundation plantings will need to be added. 6. The site is required to be platted. 7. The site will need to provide for handicapped, motorcycle, bicycle parking spaces. 8. The sign allowance is one (1) sign per street frontage. 9. The structures must include accessibility for handicapped individuals. 10. This project will require State Health Department Review. 11. Please contact the City Building Department at 221-6760 regarding the development fees. n, 12. The developer wi l l be required to widen up some of the sidewalks in order to accommodate fire apparatus i.e, amhulance and pumper. It was discussed that a 8'-12' walk would be needed. 13. Water and sewer service is available to the site. Staff would prefer that the water and sewer lines be placed in the right-of-way to the west. 14. The water line will need to be looped. 15. Water and sewer service normally has individual service for each build- ing, but it may be possible to combine them. 16. The developer will be responsible for off -site improvements at some point. Please keep in mind that a portion of the improvements to Rule and Lemay will be covered by the City's over -sizing funds. 17. Drive way access points are contingent on the traffic study results. 18. A temporary 40' radius turn -around wi l l be needed where Rule Drive stops. 19. A neighborhood meeting has been scheduled for April 28, 1987 at the Evangelical Covenant Church of Fort Collins.