HomeMy WebLinkAboutCALIFORNIA PLAZA PUD - PRELIMINARY AND FINAL - 52-89 - - RECOMMENDATION/REPORT W/ATTACHMENTSSTAFF REPORT
PROJECT: California Plaza P.U.D., Preliminary - #52-89
APPLICANT: Platte Valley Commercial Corporation
c/o Stewart and Associates
214 North Howes Street
Fort Collins, CO. 80521
OWNER: Platte Valley Commercial Corporation
13275 E. Fremont Place, Suite 205
Englewood, CO. 80112
PROJECT DESCRIPTION:
This is a request for Preliminary for a parking lot
Plaza office building located at 1730 South College
parking lot is located at the rear of the existing
parking lot is from Remington Street approximately
Street as well as from the existing lot. The property
Residential.
RECOMMENDATION: Approval
EXECUTIVE SUMMARY:
to serve the existing California
Avenue. The proposed 30 space
building. The entrance to the
240 feet north of East Stuart
is zoned R-M, Medium Density
The request is to allow a parking lot to be constructed on property zoned R-M,
Medium Density Residential. The proposed parking provides for 30 parking spaces
for the existing California Plaza office building located at 1730 South College
Avenue. The parking lot would gain access from the existing parking lot as well as
from Remington Street via a 20 foot wide drive aisle. The lot is screened from the
adjacent residential uses by a six foot solid fence with the exception of the edges
of the 20 foot drive aisle. In order to minimize the "canyon effect", the edges of
the drive aisle feature a four foot fence on the south and dense shrubbery on the
north. The proposal has been evaluated against the All Development Criteria of the
L.D.G.S. and satisfies the applicable criteria.
DEVELOPMENT SERVICES 300 LaPorte Ave. P.O. Boa 580 Fort Collins, CO 80522-0580 (303) 221-6750
PLANNING DEPARTMENT
LJ
0
California Plaza PUD, Preliminary & Final, #52-89
December 18, 1989 P & Z Meeting
Page 2
COMMENTS
Background:
The surrounding zoning and land uses are as follows:
N: R-M;
Single Family
S: R-M;
Multi -Family
E: R-M;
Single Family
W: H-B;
Of f ice
The property is part of the Maynard Subdivision which was approved in 1923. The
California Plaza office building was constructed as a use by right in the H-B zone
in 1982. The site has been vacant and used as unimproved access to the California
Plaza office building.
2. Land Use:
A parking lot that serves a commercial use in the H-B zone is not an allowed use in
the R-M, Medium Density Residential zone district, and, therefore, must be approved
as a P.U.D. As an accessory use to the office building, the parking lot P.U.D. has
been reviewed against the All Development Criteria of the L.D.G.S. and not a
specific point chart. A parking lot that is accessory to a principal "use by right"
does not meet the definition of any of the point charts yet needs to be evaluated
for impacts on the surrounding residential area.
Staff feels a parking lot at this location is an appropriate use. The parking lot is
logically connected to and functionally a part of the office plaza. The lot is well
landscaped and buffered from the adjacent residential uses along Remington Street.
3. Neighborhood Compatibility:
The proposed parking lot would be the furthest away from the office building.
Consequently, these spaces would be the least desirable and would likely experience
low turnover. Similarly, the access onto Remington Street would not be advertised
and would function as secondary rather than primary access.
The parking lot would be screened from the existing residences to the south and
east with a six foot solid fence. The adjacent residence to the north would have its
back yard screened with upright evergreen shrubs planted at a sufficient density to
provide headlight screening. Four trees would be planted along the east side of the
six foot fence and three trees would be planted on the south side of the access
drive. The access drive is bordered by landscaping and fencing of four feet in
height to minimize the canyon effect.
The entire block is divided equally along the north/south axis by a zoning line
separating H-B, Highway Business from R-M, Medium Density Residential zone dis-
tricts. For most of this block, this separation is in the form of a variety of fence
0 •
California Plaza PUD, Preliminary & Final, #52-89
December 18, 1989 P & Z Meeting
Page 3
materials which separate the rear of the College Avenue businesses from the back-
yards of the residences.
4. Parking Lot Design:
The applicable policy guidelines relating to parking lot construction are the Zoning
Code and the Parking Lot Development Guide. These documents outline the design
guidelines for parking lots. The proposed parking lot meets the intent of the
guidelines with respect to dimension of stalls and aisles, layout, amount of
landscaping, and safety.
The one exception to the guideline is the edge treatment along the 20 foot wide
drive aisle. In order to minimize the "canyon effect", the southern edge features a
four foot high fence which tapers down to two feet past the front building line of
the homes fronting on Remington. The northern edge features landscape materials
designed to block the headlights in addition to existing, mature trees. Under typical
circumstances, these edges would be treated with six foot solid fences. Staff feels it
is desirable to minimize the "canyon effect" with the lower fence height with no
detrimental effect to the adjacent properties.
5. Existing Trees:
All existing, mature trees that are on the perimeter of the parking lot will be
preserved. One large tree, located in the center of the parking lot, will be protected
by a landscaped island.
6. Stormwater Runoff:
Stormwater runoff will be collected and detained to release at a controlled rate into
the stormwater sewer system. There will be no negative impact to adjacent proper-
ties from stormwater runoff.
7. Parking Lot Lighting:
There will be two additional light fixtures mounted on 16 foot high poles. These
fixtures will be down directional and not spill onto neighboring properties.
RECOMMENDATION:
Staff finds the request for a parking lot to be an appropriate use for the subject
property. The proposed parking lot has been evaluated against the All Development
Criteria of the L.D.G.S. and meets the applicable criteria. Staff, therefore,
recommends approval of the Preliminary and Final P.U.D. for California Plaza.
Ilm
I
IMME& a N
Pit
TWA
wq
w
�a
au
97
77
LAND USA DATA
AUA OF tRAat
14,44t, 6P
R AIA eRAN06GAPIN.
NWgW OP PARKIN. AWAIT
LPi4'•i ..F
00
Ib.L•F
rs-
L J
Aeer's
I
GJcAl6 I'•ZO'
•
�Iv
V
r
N
�
I
I
} I
I
I 1
I V
� I
L
I �
I
£ I
I
aY
I
I
I��
Iz�
I
^�3
I
wtrw ewlwu
•PYW
LL
0/Pill I
ry �
4I AAPNA1t FA201
�=
I
i
13 I
I I
I
1
c
Q I
I
n
Ic
I VI
1 F
1 I
I
II
i I
II i
1
I
N
fi
I
I I
II
V IGI UITY MAP
lE<AL EWq ..
. Wrt e( \r 3 W 1 al w 2p1.\ of ,bv.! SunOt.n,m •A:c.
at w tMaat III i.4.
vrA Lot J W m JVN q.°ao h.a n rat 01 q.ee lM. � s,,,tnixio ha
M m m w qmU la W u: lot <n<no rat 6B.g1
i.i\mow ra sm\e ir�m w smltn..,t m...
I�It s>:tn w.rq tM r.tM.a\ .m... o':.'a
lea l' a �'c Fa,l I>q.qq h.\ m w m ne of M9wnq,l
amM .q 11.220yvn M1.l e.. o. In,.
EA STUAET $TEEET M1��r'•—� 'e—
O
a
i
u
STEWART&ASSOCIATES
Consulting Engineers and Surveyors
October 31, 1989
Mrs. Sherry Albertson —Clark
Senior Planner
City of Fort Collins
P 0 Box 580
Fort Collins, CO 80522
Dear Sherry:
The following are the planning objectives for the California Plaza
P. U. D.
The California Plaza P.U.D. is a planned unit development adjacent
to the California Plaza office building located at 1730 South College
Avenue, Fort Collins, Colorado. The owners of the property, Platte
Valley Commercial Corporation, have found the necessity to enlarge
the parking area and to provide access to it from Remington Street.
The original plans included a second building and access to Remington
Street, however that has changed. The Fort Collins Housing Authority
bought the two lots that front onto Remington Street. They have moved
two single family houses onto the lots. However, the two lots are
very deep and so the Housing Authority has agreed to sell the West
68.00 feet for the needed parking spaces to Platte Valley Commercial
Corporation.
The proposed parking area addition is located in a R.M. zone which
requires a planned unit development. It is proposed to construct
30 parking spaces and an access drive to Remington Street. The East
side of the parking area will have a 6.0 foot wide landscaped area
between the fence and the parking spaces. The South side will have
shrubbery screening. The West side of the lot will be adjacent to
the existing office parking. The North side of the lot is presently
fenced by Arby's Restaurant.
The North side of the access driveway presently is fenced and the
existing garage for the single family residence has a zero set back.
It is proposed to add some plantings to the existing mature Chinese
Elm trees that are in the 5.0 foot landscaping area. The South side
of the driveway will have a 4.0 foot high solid cedar fence from the
parking area to the front setback of the Housing Authority residence
at which point it will taper to 2.0 feet high at the Remington Street
right—of—way line. This will allow good site distance at the street
and eliminate any tunnel effect. There also is a 5.0 foot landscaping
area on the South side of the driveway.
James H. Stewart
and Associates, Inc.
214 N. Howes Street
PO. Box 429
Ft. Collins. CO 80522
303/482-9331
Mrs. Sherry Albertson —Clark
California Plaza P.U.D.
Page 2
The Remington Street access continues to be important in the fact
that it will reduce the turning movements on and off College Avenue.
These turning movements tend to slow the College Avenue traffic.
The Platte Valley Commercial Corporation will own the new parking
area and driveway. They will convey them with the California Plaza
Office Building at some future time. The owner plans on completing
the construction in the spring of 1990.
If you have any questions concerning this project, please call.
Sincerely,
Richard A. Rutherford, P.E. & L.S.
President
1 k k
�Ll �N ft �2 �q P.v-D. PiQEL/M/N/ A
ALL DEVELOPMENT: NUMBERED CRITERIA CHART
ALL CRITERIA
APPLICABLE CRITERIA ONLY
CRITERION
Is the criterion applicable?
Will the crlterlon
be satisfied?
If no, please explain
`�~°°°0
,0�� �� �d°
Yes No
NEIGHBORHOOD COMPATABILITY
1 Social Compatability
✓
2. Neighborhood Character
A/
3. Land Use Conflicts
4 Adverse Traffic Impact
✓
PLANS AND POLICIES
5. Comprehensive Plan
PUBLIC FACILITIES & SAFETY
6. Street Capacity
7. Utility Capacity
8 Design Standards
9. Emergency Access
10. Security Lighting
11. Water Hazards
RESOURCE PROTECTION
12. Soils & Slope Hazard
13. Significant Vegetation
14, Wildlife Habitat
15. Historical Landmark
16. Mineral Deposit
17. Eco-Sensitive Areas
18. Agricultural Lands
ENVIRONMENTAL STANDARDS
19. Air Quality
20, Water Quality
21. Noise
22. Glare & Heat
23. Vibrations
24. Exterior Lighting
25. Sewages & Wastes
SITE DESIGN
26. Community Organization
27. Site Organization
28, Natural Features
29. Energy Conservation
�. Shadows
31, Solar Access
32. Privacy
33. Open Space Arrangement
34. Building Height
✓
35. Vehicular Movement
36. Vehicular Design
37. Parking
38. Active Recreational Areas
✓
39. Private Outdoor Areas
✓
40. Pedestrian Convenience
✓
41. Pedestrian Conflicts
42, Landscaping/Open Areas
43. Landscaping/Buildings
44. Landscaping/Screening
45. Public Access
/
46. Signs